BUCKTHORN_Questions_ _Answers.doc
DOC document 26 KB Posted
- Solicitation number
- HSCG85-16-Q-P45730
About this file
BUCKTHORN Questions Answers
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BUCKTHORN _Amendment_03.pdf | ||
| BUCKTHORN _Amendment_02.pdf | ||
| Amendment_2 _ATTACHMENT_1.doc | DOC document | |
| BUCKTHORN_Questions_ _Answers _18_March.doc | DOC document | |
| BUCKTHORN _Amendment_01.pdf | ||
| BUCKTHORN _Wartsila_Shaft_Seal_Service_Report.pdf | ||
| BUCKTHORN_Questions_ _Answers_16_March.doc | DOC document | |
| BUCKTHORN_Specification_Rev_1.pdf | ||
| BUCKTHORN_RFQ_HSCG85-16-Q-P45730.doc | DOC document | |
| BUCKTHORN _Rev_0_Spec.pdf | ||
| BUCKTHORN _Rev_0_Spec.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUCKTHORN, Questions & Answers, 14 March Question: (Reference WORK ITEM #14 HULL PLATING FREEBOARD, PRESERVE-PARTIAL: 3.6 Coating application TABLE 2 STEP 2 Top Coat; top coat all primed and abraded surfaces: apply "Epoxy Polysiloxane" White (17925)). Shouldn't that be Black (17038)? The vessel is currently painted black
Answer: Yes, Freeboard Top Coat should be Black (17038).
Question: (Reference WORK ITEM #15 DRY DOCK: 3.8 Fleeting not required). If fleeting is not required. We won't be fleeting for the 100% preserve underwater body For Work Item #11?
Answer: Correct, Fleeting is not required and the U/W body surfaces defined in preservation WIs 11-13 “exclude areas covered by docking blocks.”
Question: (Reference WORK ITEM/S # 27-32 HULL AND STRUCTURAL PLATING (GENERAL): 3.2 Renewal The contractor shall renew up to 4 square feet of the steel plating. Attachment 1 Schedule of supplies/services: for those work items they are asking for the price of 1 square foot). Are these work items going to be based upon CFR's and CIR's and implemented as per the square footage required?
Answer: Work Item will be bid on price of 1 square foot, and expanded, as necessary, via CFR and change requests. The Work items should read “1 square foot increments.”
Question: (Reference WORK ITEM #37 PROPULSION SHAFT PACKING, RENEW: The vessel is currently equipped with a Wartsila dripless shaft seal. Shaft packing does not exist). Will this work item be deleted from the solicitation?
Answer: WI 37 should actually be Wartsilla seals and WI needs to be changed from packing to drip less seals also GFE should reflect this.
File details come from the government source that posted it. Updated .