J-2_21-17-827PAT002-Drawings.pdf

PDF 10 MB Posted

Attached to
MAJOR M&R MEDICAL/DENTAL CLINIC AVIATION TRAINING CENTER
Solicitation number
HSCG82-17-B-PAT002
Issued by

About this file

J-2_21-17-827PAT002-Drawings

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PL

A N

N O

R

TH

ATC BASE MAP

N.T.S.

NORTH

o

MISSISSIPPI

ALABAMA98

o

CENTER ENTRANCE

AVIATION TRAINING

U.S. COAST GUARD

o p p10

MOBILE

BAY

GULF OF MEXICO

MOBILE

MUNICIPAL

AIRPORT

TANNER

W

ILLIAMS RD.

p

FLORIDA

ALABAMA

PROJECT

LOCATIONLOCATION MAP

N.T.S.

NORTH

VIC INITY M AP

ROADCODY

ZIEGLER RD

ROAD

ROAD

OLD SHELL RD.

BOULEVARD

AIRPORT

N.T.S.

SCHILLINGER

TANNER

NORTH

MAIN G ATE ENTRANC E

U.S. CO AST GUARD

AVIATIO N TRAINING C ENTER

MUNIC IPAL AIRPORT

BATES FIELD

WILLIAMS

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DEPARTMENT OF HOMELAND SECURITY

UNITED STATES COAST GUARD

AVIATION TRAINING CENTER

8501 TANNER WILLIAMS ROAD

MOBILE ALABAMA

PLOT SCALE: D SIZE

SHEET OF

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

As indicated

7088488

MAJOR M&R MEDICAL CLINIC

(S24)

DESIGNED BY: EOH

EDITED BY: RAC

S247088488G001

G001

Title Index Site

DRAWN BY: EOH

CHECKED BY: NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488G001

PROJECT NUMBER:7088488

MAJOR M&R MEDICAL CLINIC (S24)

Nov 2016

DRAWING INDEX

SHT NO Drawing Title

SHEET_

NO

G001 Title Index Site 1 G002 Code Check 2 G003 Code Check 3 G100 Life Safety Plan 4 S301 Existing Ceiling Structual Constraints 5 A101 Medical Demo Floor Plan 6 A102 Dental Demo Floor Plan - OPTIONS 7 A103 Medical Reflective Ceiling Demo Plan 8 A104 Medical Proposed Floor Plan 9 A105 Dental Proposed Floor Plan - OPTIONS 10 A106 Medical Proposed Reflective Ceiling Plan 11 A107 Roof Demo Plan 12 A108 Roof Proposed Plan 13 A201 Exterior Demolition Elevations 14 A202 Exterior Proposed Elevations 15 A203 Interior Proposed Room Elevation 16 A204 Interior Proposed Room Elevation 2 17 A205 Interior Proposed Room Elevation 3 18 A301 Proposed Building Sections 19 A501 Partition Details 20 A502 Window, Door, Roof Detail & Schedule 21 A503 Casework Detail 22 A601 Schedules 23 A901 3D Representation of Proposed 24 A902 Realistic 3D Representation 25 P101 Existing Plumbing Plan 26 P102 Proposed Plumbing Plan 27 P401 Large Scale TYP EXAM & PHAR RM 28 P601 Schedule / Lab Toilet and OPTIONS 29 P901 Proposed Plumbing Orthogonal 30 M101 Medical Demo Ceiling Plan 31 M103 Medical Demo Subfloor Plan 32 M104 Medical Proposed Ceiling Plan 33 M105 Medical Proposed Floor & Subfloor 34 M601 Mechanical Schedule 35 M602 Control Diagram AHU-1 and OAHU-2 36 M603 VAV and FCU Control Diagram 37 M604 Chilled & Hot Water Service Controls 38 M901 HVAC Orthogonal 39 E101 Medical Demo Power Floor Plan 40 E102 Medical Proposed Power Floor Plan 41 E105 Medical Demo Lighting Plan 42 E107 Medical Proposed Lighting Plan 43 E601 Electrical Single Line & MDP Schedule 44 E602 Panel Schedule 45 T101 Proposed Telecommunication Floor Plan 46 T102 Proposed Telecommunication RCP 47

Facilities Engineering Building

Main Entrance To Base

Project Location

ID DATE DESCRIPTION

1 25/04/16 10% Deliverable 2 25/05/16 30% Deliverable 3 15/07/16 60% Deliverable 4 14/10/16 90% Deliverable 5 18/11/16 100% Deliverable

KEY PLAN AND ORIENTATION

DRAWING ABBREVIATIONSINDEX OF DRAWINGS BUILDING CODE SUMMARY

ARCHITECTURAL LEGEND

NUMBERING SYSTEM:

A210

DISCIPLINE:

G - GENERAL

C - CIVIL

L - LANDSCAPE

S - STRUCTURAL

A - ARCHITECTURE

F - FIRE PROTECTION

P - PLUMBING

M - MECHANICAL

E - ELECTRICAL

T - TELECOMM

SHEET NUMBER

WITHIN SERIES:

ANNOTATION CALLOUTS/DRAWING SYMBOLS

CEILING AND LIGHTING SYMBOLS

00000

1i

0 GRID / COLUMN

LINE DESIGNATOR

EQUIPMENT NUMBER

DOOR NUMBER

EXIT LIGHT

INTERIOR ELEVATION

1t

WALL TYPE

WINDOW # AND TYPE

A101

SIM

SECTION

A101

Ref

A101

Ref

EXTERIOR ELEVATION

A-101

SIM

PLAN, BLOW-UP

DETAIL

PLAN NORTH

NORTH ARROW w/

TRUE NORTH

INDICATION

SPOT ELEVATION

Name Elevation FLOOR LEVEL &

NAME

PLATE NUMBER WHERE

SECTION/DETAIL IS

DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS

DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

2' x 2' ACT CEILING

A

2 HR WALL

SHEET KEYNOTE

GYP. BD. CEILING

2 x 2 LED LIGHT FIXTURE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

Room Rm_Occupancy

150 SF

ROOM

OCCUPANCY &

AREA

SERIES NUMBER:

0 - GENERAL

1 - PLANS

2 - ELEVATIONS

3 - SECTIONS

4 - LARGE-SCALE VIEWS

5 - DETAILS

6 - SCHEDULES & DIAGRAMS

8 - USER DEFINED

9 - 3D REPRESENTATIONS

S

2x4 RECESSED FLUORESCENT

LIGHT FIXTURE

RECESSED DOWNLIGHT

EXISTING WALL TO REMAIN

EXISTING WALL TO DEMOLISH

NEW WALL

NEMA 5-20 DUPLEX RECEPTACLE MOUNTED FLUSH IN THE FLOOR UNLESS NOTED OTHERWISE.

NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 18" AFF UNLESS NOTED OTHERWISE. (AC

INDICATES ABOVE COUNTER)

UNFUSED DISCONNECT SWITCH. SIZE AS SHOWN

FUSED DISCONNECT SWITCH. SIZE FUSES FOR EQUIPMENT BASED ON MANUFACTURERS

RECOMMENDATIONS

SURFACE MOUNTED PANELBOARD OR AUTOMATIC TRANSFER SWITCH AS INDICATED.

MOTOR, SIZE AS SHOWN. UNLESS NOTED OTHERWISE. (AC INDICATES ABOVE COUNTER)

F

RECESSED MOUNTED PANELBOARD

ELECTRICAL LEGEND

POWER

WIRING

MECHANICAL LEGEND

HASH MARKS INDICATES NUMBER OF CONDUCTORS RAN IN CONDUIT. NO HASH MARKS

INDICATES 1 #12 PHASE CONDUCTOR, 1#12 GROUNDED CONDUCTOR AND 1 #12 GREEN

EQUIPMENT GROUND IN 1/2" CONDUIT.

2x4 FLUORESCENT LIGHT

FIXTURE ALWAYS ON

B1.Xs

CARPET

VCT OR SHEET VINYL FLOOR

WALL AND FLOOR PLAN SYMBOLS

A ---------------------

A/C AIR CONDITION

A/E ARCHITECT/ENGINEER

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADMIN ADMINISTRATION

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

ARCH ARCHITECT

ASM ASBESTOS CONTAINING MATERIAL

B ---------------------

BLDG BUILDING

BLKG BLOCKING

BRZ BRONZE

C ---------------------

CA COMPRESSED AIR

CAB CABINET

CFM CUBIC FEET PER MINUTE

CLG CEILING

CLO CLOSET

CLR COLOR

CONF CONFERENCE

COR CONTRACTING OFFICER REP

CORR CORRIDOR

CPT CARPET

CSWK CASEWORK

CSR CENTRAL STERALIZATION ROOM

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CW COLD WATER

CW CASEMENT WINDOW

D ---------------------

D DEPTH

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DR DOOR

DS DOWNSPOUT

E ---------------------

EA EACH

E EAST

EF EXHAUST FAN

EQ EQUAL

EQUIP EQUIPMENT

EXAM EXAMINATION

EX EXISTING

H -------------

HB HOSE BIBB

HDPE HIGH DENSITY POLYETHYLENE

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR

(FILTER)

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HORIZ HORIZONTAL

HT HEIGHT

F ---------------------

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FCU FAN COIL UNIT

FD FLOOR DRAIN

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FF FINISH FACE

FLR FLOOR

G ---------------------

GLZ GLAZING

GR FL GROUND FLOOR

GUT GUTTER

GYP BD GYPSUM BOARD

GWB GYPSUM WALL BOARD

H ---------------------

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR

(FILTER)

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HORIZ HORIZONTAL

HT HEIGHT

HYDR HYDRAULIC

HW HOT WATER

I ---------------------

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

INT INTERIOR

J ---------------------

JAN JANITOR

K ---------------------

KIT KITCHEN

KPL KICKPLATE

L ---------------------

LAM LAMINATE

LAV LAVATORY

LBS POUND

LDG LANDING

LF LINEAR FEET (FOOT)

LT LIGHT

M ---------------------

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MFR MANUFACTURER

MIRR MIRROR

MISC MISCELLANEOUS

MOD MODIFY

MTG MOUNTING

MTL METAL

N ---------------------

N NORTH

NA NOT APPLICABLE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NS NURSE STATION

NTS NOT TO SCALE

O -------------------

OA OUTSIDE AIR

OPNG OPENING

OPP OPPOSITE

OPT OPTION

P --------------------

PA PUBLIC ADDRESS

PC PATIENT CARE

PE PHYSICAL EXAMINATION

PHAR PHARMACY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTDR PAPER TOWEL DISPENSER AND

RECEPTACLE

PTN PARTITION

PWR POWER

Q --------------------

QT QUARRY TILE

QTY QUANTITY

R --------------------

RB RESILIENT BASE

RBR RUBBER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REST RESTROOM

RL ROOF LADDER

RM ROOM

S --------------------

S SOUTH

S SANITARY

SB SPLASH BLOCK

SD SOAP DISPENSER

SF SQUARE FOOT (FEET)

SPEC SPECIFICATION

SPKR SPEAKER

STC SOUND TRANSMISSION CONTROL

SHVF SHEET VINYL FLOORING

T --------------------

TPH TOILET PAPER HOLDER

TYP TYPICAL

TV TELEVISION

UVWXYZ -----------------

VCT VINYL COMPOSITION TILE

W WEST

WD WOODEN DOOR

V VENT

VTR VENT THROUGH ROOF

PAGE SPECIFIC NOT

IN SCOPE

PAGE SPECIFIC NOT

IN SCOPE

2x4 SURFACE OR GYPSUM

FLUORESCENT LIGHT FIXTURE

1x4 SURFACE OR GYPSUM

FLUORESCENT LIGHT FIXTURE

CEILING SPEAKER

OS CEILING MOUNTED

OCCUPANCY SENSOR

EGRESS PATH

EXIT SIGN

FIRE ALARM HORN AND

STROBE

MANUAL PULL STATION

L-1,3

HOMERUN TO PANEL `L', CONNECT TO CIRCUIT NO.'S "1 & 3". EXAMPLE: 2#12 (PH), 1#

12 (N) & 1#12 GRD

1 HR WALL

LIGHT SWITCH DIMMER

LIGHT SWITCH THREE WAY

LIGHT SWITCH SINGLE POLE

CEILING MOUNTED SENSOR DUAL TECHNOLOGY

TYPICAL DATA OUTLET

NURSE STATION DATA OUTLET

CONFERENCE ROOM DATA OUTLET

M

F S

24x16

20/12

ROUND DUCTWORK

FLAT OVAL DUCTWORK

RECTANGULAR DUCTWORK, WxH

SQUARE ELBOW W/TURNING VANES

SUPPLY, RETURN, & EXHAUST DUCT

DROP/RISER

SIDEWALL RETURN GRILLE/REGISTER

MOTORIZED AND MANUAL VOLUME DAMPER

FIRE DAMPER SMOKE DAMPER

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

As indicated

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488G002

G002

Code Check

EOH

NCP

LCDR P F Bosma

GENERAL

IN HOUSE

S247088488G002

Nov 2016

ID DATE DESCRIPTION

During installation, it is anticipated that slight deviations from the design will be necessary to complete the work. Contractor shall mark these deviations in red on the construction drawings. Major changes from the design must be approved by contracting officer and engineer.

BUILDING CODE SUMMARY

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

3/16" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488G003

G003

Code Check

EOH

NCP

LCDR P F Bosma

GENERAL

IN HOUSE

S247088488G003

Nov 2016

ID DATE DESCRIPTION

R

EF

M

M M

MF

F

F

F

Ref

81' - 11" TOTAL DISTANCE

TRAVEL FROM LAB

5'

8"

T O

TA

L

D

IS

TA

N

C E

TO

AL

TE

R

N

AT

IV

E

EX

IT

2 HR WALL

EGRESS PATH

EXIT SIGN

FIRE ALARM HORN

AND STROBE

MANUAL PULL STATION

1 HR WALL

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

As indicated

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488G100

G100

Life Safety Plan

EOH

NCP

LCDR P F Bosma

GENERAL

IN HOUSE

S247088488G100

Nov 2016

ID DATE DESCRIPTION

GENERAL NOTES

SHEET KEYNOTES

SCALE AND ORIENTATION

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

1/2-HR RATED WALLS: Extend wall to underside of deck above. Provide 20 minute rated doors and closers unless noted otherwise.

Fire dampers and smoke dampers for ductwork penetrations not required unless penetrated into shaft. Firestop all gaps around penetrating items through walls. Provide firestopping in gap between wall and deck above.

1-HR RATED WALLS: Extend wall to underside of deck above. Glazed openings require 3/4-hr rating. Provide 3/4-hr label doors and closers unless noted otherwise. Fire dampers and smoke dampers for ductwork penetrations not required unless penetrated into shaft. Firestop all gaps around penetrating items through walls.

Provide firestopping in gap between wall and deck above.

PL

AN

N O

TH

C4 S301

A2 S301

A4 S301

A1 S301

18K5

18K5

18K5

W10X17

18K5

18K5

18K5

18K5

18K5

W10X17

18K5

18K5

18K5

W12X22

18K5

18K5

18K5

18K5

18K5

W10X17

18K5

18K5

18K5

W10X17

18K5

18K5

18K5

18K5

W10X17

18K5

W

X3

L5 X3

X1 /2

18K518K518K5

18K518K518K5

18K518K518K5

18K518K518K5

HSS4X0.313

1'

6"

1"

1'

2" 8'

6"

9"

W14X34

W10X17

1 1/2"ø V

18K5

HSS4X0.313

A.F.F.

GWB demo 8' - 6"

#CURB-3

#EF-3

W18X50

W12X26

FLR1 - 4"

Concrete Slab

Elevated 1'

6"

8'

6"

2"

7"

1' - 0"

A.F.F.

GWB demo 8' - 6"W14X3418K5

#EF-3

#CURB-3

1 1/2"ø V

HSS4X0.313

W10X17

Ductwork contraint for this ceiling section

8'

2"

PL

A N

N O

R

TH

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

As indicated

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488S301

S301

Existing Ceiling Structual Constraints

EOH

NCP

LCDR P F Bosma

STRUCTURAL

IN HOUSE

S247088488S301

Nov 2016

3/16" = 1'-0" C1

Existing Ceiling Plan Constraints to Ductwork 1/2" = 1'-0"

S301

C1 C4 Urgent Care Hallway South Section

1/2" = 1'-0"

S301

C1 A2 Exist Location for NS North View

1/2" = 1'-0"

S301

C1 A4 Urgent Care Hallway East Section

1/2" = 1'-0"

S301

C1 A1 Exist Location for NS West View

1. The contractor is to notify the COR if conditions differing from those stated are uncovered in the demolition process.

2. Coordinate architectural and structural dimensions prior to fabrication and assembly of any building components. In event of a discrepancy, contact COR and obtain written resolution prior to proceeding with the work.

3. Contractor shall keep the job free of debris and make final cleanup to the satisfaction of the COR. Contractor shall be responsible for removal of all construction debris from project site and shall provide dumpsters etc.

As required. Remove all debris on a daily basis.

4. Contractor shall be responsible for the protection of all existing buildings and other installations that are to remain intact while performing the specified work. Provide and maintain fire extinguishers on project site during construction.

5. Unless indicated otherwise, all material furnished and incorporated into the work shall be new, unused and of quality standard to the industry for first class work of similar nature and character. Install all materials to the manufacturer's recommendations and best standard of the trades involved.

6. Contractor shall field verify all dimensions in field prior construction. Notify engineer of any discrepancies on drawings.

7. Visit the site to verify existing conditions.

Existing concealed conditions and connections are based upon information taken from limited field investigations.

Contractor shall make required adjustments to system components as necessitated by actual field conditions at no additional cost to government. Report any discrepancies between the drawings and actual field conditions to the COR before construction begins.

8. Contractor to obtain and provide COR with color samples for proper color selection and final approval of all finishes prior to installation

GENERAL NOTES

SCALE

KEY PLAN AND ORIENTATION

1 2 42

SCALE: 1/2"=1'-0"

SCALE: 3/16"=1'-0"

48 8

B1 A201

A201 D1

Ref Ref

A201

C1

A1 A201

8' - 1"

10' - 8"

0"

" 7' - 1"

5'

4" 8"

5' - 5"

5' - 0"

7'

5' - 9"

5'

0"

5' - 5"

5' - 7"

13' - 0"

11' - 0"

31' - 0"

3 3

2 2

2 2

1 111

1 1

A102 A1

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

3/16" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A101

A101

Medical Demo Floor Plan

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A101

Nov 2016

3/16" = 1'-0" A1

Demo Medical Floor Plan

GENERAL DEMOLITION NOTES

SHEET KEYNOTES

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

1 Remove existing finished flooring and adhesive. Scrape and clean in order to prepare slab for scheduled finishes as required by manufacturer for proper installation.

1. Owner will occupy dental wing of the building. G.C. is to coordinate demolition to not disturb owner/client daily tasks.

2. The drawings are intended to show the extent of demolition. The drawings are not to be construed as indicating all existing conditions. Contractor is responsible to verify existing conditions and dimensions.

3. Refer to mechanical, electrical, plumbing, fire, and telecom drawings for demolition of respective equipment.

4. All demolition work shall be coordinated with new work.

5. Patch all surfaces disturbed by demolition to match existing adjacent surfaces.

6. All existing work damaged during demolition shall be repaired to it pre-existing condition.

7. All items noted in RED are to be demolished.

8. The second drawing scale is for half size "B" sheet printouts

2 Remove existing door, frame and hardware complete. Coordinate salvage with COR. Patch wall where opening is to be closed up.

3 Remove window complete.

4 Remove plumbing and cap in wall.

Coordinate salvage of vanity and medical casework with COR. Contractor to verify in field all utility connections required to meet the new design, refer to electrical, mechanical, and plumbing drawings.

Patch/ repair all demolished areas to pre-construction condition.

5 Remove and reset FCU for installation of new gypsum wall and furring.

6 Remove portion of interior wall.

Adequately support adjacent structures and components until new walls are installed. Appropriately patch floor where wall was removed.

7 Remove existing fire hose wall cabinet, patch wall, and install new fire extinguisher cabinet.

9 Remove and dispose of existing base and wall casework and cabinets

8 Remove wall tile finish.

10 Demolish plumbing walls taking care not to damage supply lines, sanitary lines and vent lines.

11 Old xray room is lead lined and is a separate substrate under existing gypsum.

Remove completely and coordinate salvage/disposal with COR.

12 Existing structural columns to remain. Do not damage during demolition. Frame and finish as an architectural column

13 Prep floor to accomdate new wall and room area.

14 Demolish door opening and patch wall.

remove wall section above drop ceiling

ID DATE DESCRIPTION

SCALE

15 Remove "Kardex Lektriver Series 2000" storage system. coordinate salvage with

COR.

16 Relocate water fountain

GFCI GFCI

G

FC

I

M

F

F

GFCIGFCIGFCIGFCIGFCIGFCI

G

FC

I G

FC

I

M

Ref

A102 A2

A102 A5

A102

A102 A3

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

As indicated

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A102

A102

Dental Demo Floor Plan - OPTIONS

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A102

Nov 2016

3/16" = 1'-0" B1

Demo Dental Floor Plan

1/4" = 1'-0"

A102

B1 1 OPTION 1 - Demo Dental Floor Plan

3/8" = 1'-0"

A102

B1 A2 OPT 2b - CSR Dirty Clean Rm

3/8" = 1'-0"

A102

B1 A5 OPT 2d -XRAY

3/8" = 1'-0"

A101

A1 A1 OPT 2a - Jan Clo

3/8" = 1'-0"

A102

B1 A3 OPT 2c - Lab

SHEET KEYNOTES

SCALE AND ORIENTATION

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

SCALE: 3/8"=1'-0"

24 4

GENERAL BID OPTION NOTES

1. Bid option 1: Replace flooring in joint waiting room.

2. Bid option 2: Provide a bids for all of option 2 (a,b,c,d)

1 Remove existing finished flooring and adhesive. Scrape and clean in order to prepare slab for scheduled finishes as required by manufacturer for proper installation.

2 Remove and dispose of existing base and wall casework/cabinets. Remove sink and plaster trap, coordiante salvage with COR.

3 Remove mop sink coordinate salvage with

COR.

4 Prep wall for installation of new door and frame.

5 Prep wall for installation of new specimen pass threu window

5 164 8268

SCALE: 1/8"=1'-0"

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

ID DATE DESCRIPTION

PL

AN

N O

R THRelocate compressed air conister and lines to new location

Cap 1 1/2" fire sprinkler line and relocate sprinkler to new room

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

3/16" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A103

A103

Medical Reflective Ceiling Demo Plan

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A103

Nov 2016

3/16" = 1'-0" A1

Demo Reflective Ceiling Medical

SHEET KEYNOTES

SCALE AND ORIENTATION

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

1 Completely remove gypsum ceiling and furring. Maintain existing lighting and other ceiling supported components.

Coordination with COR and other discipline.

2 Demolish existing light fixtures 3 Relocate existing light fixtures 4 Remove and dispose of the existing acoustical ceiling grid and tiles.

5 Remove and salvage smoke detector.

Coordinate disposition with COR.

6 Remove and salvage PA speakers.

Coordinate disposition with COR.

Remove PA conduit.

7 Remove exhaust and supply registers/grill.

8 Remove exhaust and supply registers/grill.

Patch gypsum ceiling that will remain.

8 8

7 7

7 7

6 6

3 33

2 2

7 7

2 2 2

2 2

2 2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2 2

2 2

2 2

2 2 2

2 2

7 7

1 1 1

1 1

1 1

2 2

9 Demolish drywall ceiling above ACT ceiling

10 Intake is above drop ceiling

10 8

11 All items noted in red are to be demolished or salvaged

ID DATE DESCRIPTION

1 25/04/16 10% Deliverable

PL

AN

N O

A202 1

MDP

Ref Ref

5'

8' - 7" 5" 20' - 9"

22' - 11" 5" 14' - 5"

90.86 SF

Office GS RN

91.48 SF

Exam Rm 4

329.07 SF

Conference

86.01 SF

Phy Exam

239.11 SF

Lab

56.79 SF

Telecom

94.81 SF

LCPO

105.22 SF

Patient Care Team Rm

107.82 SF

Phy Exam

8' - 1" 1' - 5" 7' - 10" 8' - 11" 6' - 3" 14' - 2" 23' - 2"

9'

7"

8'

9"

15' - 8" 8' - 9" 19' - 4" 8' - 4" 6' - 9" 11' - 2" 1' - 4" 19' - 7" 5' - 5"

16' - 4" 8' - 8"

9'

3"

8'

4"

170.14 SF

Foyer 3

109.16 SF

Exam Rm 6

100.34 SF

Office 6

94.90 SF

Exam Rm 5

103.16 SF

Office 2

92.11 SF

Exam Rm 3

85.96 SF

Exam Rm 2

163.75 SF

Office 1

100.69 SF

Exam Rm1

82.39 SF

Pharmacy Storage

140.15 SF

Pharmacy Office

192.56 SF

Pharmacy Issue

304.06 SF

Pharmacy Waiting

149.17 SF

GS Referral Office

221.67 SF

Break Room

25.64 SF

Telecom

103.45 SF

Duty Room

235.90 SF

Toilet / Locker Rm / Shower

97.51 SF

Eye Exam

70.22 SF

Phy Exam

31.39 SF

Toilet

40.11 SF

Circulation

92.76 SF

PC Super

93.37 SF

PE Super

130.00 SF

Nurse Station

699.94 SF

Storage

78.95 SF

Hall 7

260.17 SF

Mechanical

211.18 SF

Administrative hallway

100.73 SF

Foyer 2

21.55 SF

Foyer PC

199.35 SF

Hall 1

341.62 SF

Hall 2

217.62 SF

Hall 3

64.46 SF

Foyer 1

161.95 SF

Hall 4

104.96 SF

Hall 5

26.86 SF

Janitor

9' - 5" 9' - 9"

1"

PL

A N

N O

R

TH

6' - 5"

15' - 2"

A1

A1

B1

A3

A3

A202

A2024

178.84 SF

Restroom

5"

A202

3' - 6"

5'

6"

9' - 8" 5" 9' - 6"

A1

A1

A1

A1

A1

A1

B1

A1

A1

A1

B1

B1

B1

B1

B1

A1

A1

A1

A1

A1

B1

A105 A1

C1 A301

A1 A301

A3 A301

A3

A203

A205

A204 D5 A204

A3

C3 A301

D4D1

D2

B1

A205

C2

C1

282283

18 19

20 21

22 23

A5 A301

A2032

B5

A1 D1

38.06 SF

Foyer 3

D3 B3

64.50 SF

Janitor Closet

60.42 SF

Toilet

149.50 SF

Clinical Admin Office

FLR1 - 4"

Concrete Slab

Elevated

VCT 2

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

3/16" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A104

A104

Medical Proposed Floor Plan

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A104

Nov 2016

3/16" = 1'-0" A1

Proposed Medical Floor Plan

GENERAL KEYNOTES

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

1 Install new flooring and base per schedule. Contractor will provide at least 3 varieties based on specifications for final selection by COR.

2 Install new wall per wall detail. Finish in accordance with schedule.

SHEET KEYNOTES

1. All interior steel studs shall not be lighter than 20 gauge and spaced 1'-4" on center.

2. Provide double studs at each side of all openings from floor to top runner.

3. When insulation is indicated in partition, construct an acoustical partition full height and to the STC rating if indicated, if not assume 45.

4. Provide insulation for full depth, width and height of stud cavity and seal all penetrations and perimeter with acoustic sealant.

5. Refer to reflected ceiling plans for locations of fire rated/smoke partitions. Seal wall at structure, floor and at all penetrations.

6. All gypsum board used shall be 5/8" type X unless otherwise noted.

7. Refer to room finish schedule for all wall finishes.

8. Partitions are typically dimensioned from face of partition to column center line or face of adjacent partition, unless noted otherwise.

9. Finishes on partitions extend to 4" above acoustical ceiling systems, unless otherwise noted. Tape and seal joints above ceiling.

10. All gypsum board work shall be done in accordance with the drywall constriction handbook, latest edition, prepared by united states gypsum. All joints and seams shall be taped and finished in accordance with manufacturer's installation recommendations.

11. Painting for gypsum board and wood constriction - provide two (2) finish coats of premium grade paint over single coat of compatible primer

3 Install new medical modular casework composed of a wall cabinet, base cabinets, sink and fixtures modular units.

Similar to style noted in render drawing.

Final type and style to be approved by COR. Install new plumbing under sink.

4 Install new door, frame and hardware per door detail and schedule. Final type and color selection to be made by COR in accordance with specification.

5 Install new specimen pass thru window 6 install new customer service window. Type

PW SHEET A502

7 Install new medical laboratory casework composed of a wall cabinet, base cabinets, sink and fixtures. Install new plumbing under sink.

8 Install new rolling counter shutter unit

4 4

4 4

1 1

1 1

9 Extend existing wall to bottom of roof deck. Provide appropriate phyiscal security and privacy barrier. See detail A501/B5

9 9

10 New nurse station casework. Architectural covering for structural support column

ID DATE DESCRIPTION

SCALE 11 New fire extinguisher cabinet 12 Relocated water fountain 13 Pharmacy shelving see detail A503/C4

9 9

13 11

GFCI GFCI

G

FC

I

M

F

F

GFCIGFCIGFCIGFCIGFCIGFCI

GFCI

G

FC

I G

FC

I

GFCI

M

Ref Ref

513.54 SF

Joint Waiting Room

302.83 SF

Front Desk

154.84 SF

Medical Records

120.65 SF

Dental Staff

145.46 SF

Dental Officer

120.80 SF

Dental Officer

116.44 SF

Dental Oper

117.66 SF

Dental Oper

117.66 SF

Dental Oper

117.66 SF

Dental Oper

75.24 SF

CSR Dirty

43.59 SF

CSR Clean

43.44 SF

Restroom

45.44 SF

Restroom

409.32 SF

Hall

40.96 SF

Dental Lab

59.34 SF

Supply

82.18 SF

Pao XrAY

200.82 SF

Mechanical Room

15.65 SF

Closet

20A205A1

A2

A105 A2

A105 A5

A105 C4

A105 A3

A205C4

C5

A205

D5

FLR1 - 4"

Concrete Slab

FLR1 - 4"

Concrete Slab

FLR1 - 4"

Concrete Slab

FLR1 - 4"

Concrete Slab

FLR1 - 4"

Concrete Slab

A205C4

C5

A205A1

A2

A205

D5

A205

C2

C1

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

As indicated

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A105

A105

Dental Proposed Floor Plan - OPTIONS

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A105

Nov 2016

3/16" = 1'-0" B1

Proposed Dental Floor Plan

1/4" = 1'-0"

A105

B1 C4 OPTION 1 - Demo Dental Floor Plan New

3/8" = 1'-0"

A105

B1 A2 OPT 2b - CSR Dirty Clean Rm New

3/8" = 1'-0"

A105

B1 A3 OPT 2c - Lab New

3/8" = 1'-0"

A105

B1 A5 OPT 2d -XRAY New

SHEET KEYNOTES

SCALE

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

SCALE: 3/8"=1'-0"

24 4

GENERAL BID OPTION NOTES

1. Bid option 1: Replace flooring in joint waiting room.

2. Bid option 2: Provide a bid for all of option 2 (a,b,c,d)

3/8" = 1'-0"

A104

A1 A1 OPT 2a - Jan Clo New

1 Install new flooring and base per schedule. Contractor will provide at least 3 varieties based on specifications for final selection by COR.

2 Install new wall per wall detail. Finish in accordance with schedule.

4 Install new door, frame and hardware per door detail and schedule. Final type and color selection to be made by COR in accordance with specification.

5 Install new specimen pass thru window

3 Install new medical laboratory casework composed of a wall cabinet, base cabinets, sink and fixtures. Install new plumbing under sink.

6 Install new door on existing frame

7 Install and plumb mop sink.

8 Install Janitorial closet shelving

ID DATE DESCRIPTION

9 Provide wall mounted dental fume hood.

Connect to existing exhaust duct.

10 Relocate dental lab plaster trap.1

9' - 7"

1"

5' - 9"

9'

8"

20' - 9"

6' - 5"

0"

4"

4"

6" 5"

22' - 11"

9' - 7"

6'

1"

5'

0"

C1 A301

A1 A301

A3 A301

A203

A205

A204 D5 A204

A3

C3 A301

D4D1

D2

B1

A205

C2

C1

A2032

B5

A1 D1

D3 B3

2' x 2' ACT CEILING

GYP. BD. CEILING

2 x 2 LED LIGHT FIXTURE

2x4 RECESSED FLUORESCENT LIGHT

FIXTURE

2x4 FLUORESCENT LIGHT FIXTURE ALWAYS ON

PAGE SPECIFIC NOT

IN SCOPE

2x4 SURFACE OR GYPSUM

FLUORESCENT LIGHT FIXTURE

1x4 SURFACE OR GYPSUM

FLUORESCENT LIGHT FIXTURE

EXIT LIGHT

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

S

RECESSED DOWNLIGHT

CEILING SPEAKER

OS CEILING MOUNTED

OCCUPANCY SENSOR

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

3/16" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A106

A106

Medical Proposed Reflective Ceiling Plan

EOH

SEP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A106

Nov 2016

3/16" = 1'-0" A1

Proposed Reflective Ceiling Medical

Legend

SHEET KEYNOTES

SCALE AND ORIENTATION

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

1 New ceiling per schedule.

2 New energy efficient recessed light panel under 2 inch thick, per schedule and specifications.

3 New ceiling mount occupancy sensor for private offices and examination rooms noted on the adjacent reflective ceiling plan.

4 New supply diffuser 5 New ceiling mounted PA speakers.

6 New exhaust grill 7 Reinstall light fixtures 8 Reinstall smoke detectors 9 New recessed canned LED light fixture

10 Remove and reinstall ceiling tiles in order to accomplish coordination work with other disciplines

3 1

4 4

4 ???

4 ???

ID DATE DESCRIPTION

PL

AN

N O

R

TH

11 Install patient room privacy curtain and track for tiled ceiling11

#EF-5

#CURB-5

4"ø

4"ø

4"ø

4"ø

4"ø

4"ø 4"ø

S

74' - 7" 27' - 7" 59' - 2"

3'

3"

VTR

VTR

VTR

VTR

VTR

VTR

VTR

Special roof drain running within building above drop ceiling

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

1/8" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A107

A107

Roof Demo Plan

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A107

Nov 2016

1/8" = 1'-0" B1

Demo Roof Plan

GENERAL SHEET NOTES

SHEET KEYNOTES

SCALE AND ORIENTATION

8 16 3241216

SCALE: 1/16"=1'-0"

164 8268

SCALE: 1/8"=1'-0"

1. Existing lightning protection components air terminals (rods), conductor (cable), mounting plates, etc, attached to the existing modified bitumen roof to be removed and temporarily supported in order to demolish and re-install new roof.

2. All items noted in red are to be removed for salvage or demolition.

3. All demolished material not designated for salvage to be removed and disposed of off of ATC by contractor.

4. All VTR and conduit penetrations to remain.

5. Where indicated remove and discard existing modified bitumen roof assembly complete. Remove roof membrane, crickets, insulation, flashing, etc to structural substrate. Plan for 5 percentage of existing metal deck to be replaced due to water damage and abandoned roof openings. Provide a cost per square foot bid option.

6. Comply with roofing manufacturers requirements for tie-in of new roof to existing roof.

7. All wood material is to be pressure treated

ID DATE DESCRIPTION

1 Remove and salvage roof exhaust for reinstallation. Coordinate with mechanical to confirm capacity.

2 Remove and salvage roof exhaust.

Coordinate disposition with COR

3 Remove roof membrane, crickets, insulation, flashing, etc to structural substrate.

4 Remove and dispose of roof equipment curb.

5 Existing strainer and drain assembly to be removed to top of downspout. Salvage strainer and drain assembly. Coordinate disposition with COR.

6 Existing expansion joint and blocking under coping and ply to be removed to metal roof deck.

7 Existing flashing, fascia and soffit to be removed.

8 Repair blister on dental wing roof. Roof is currently under 20-year warranty till 2020 with RL Campbell. Coordinate warranty work to repair blisters. Estimate 15 percent of roof membrane to be patched in accordance with manufacturers guidelines for blister repair.

7 7

4 4 4

4 4 4 4

2 111

9 Canopy not original construction. Assume wood assemble and reconstruction is required.

10 Boiler Stack over mechanical room 11 Pipe peneration over mechnical room

12 Abandoned roof curb over mechanical room

PL

A N

N O

3'

74' - 10" 27' - 3" 59' - 2"

1/ 8"

1/

4"

1/4" / 12" 1/8" / 12"

3/4" / 12"

3/4" / 12"

1/4" / 12"1/8" / 12"

1/ 8"

1/

4"

1/ 4"

1/

4"

3/8" / 12"

3/8" / 12"

#EF-7 #EF-6 #EF-8

#EF-4 #EF-9

#EF-10

#EF-1

#EF-2

1/8" = 1'-0" B1

Proposed Roof Plan

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

1/8" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A108

A108

Roof Proposed Plan

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A108

Nov 2016

ID DATE DESCRIPTION

GENERAL NOTES

SHEET KEYNOTES

SCALE AND ORIENTATION

8 16 3241216

SCALE: 1/16"=1'-0"

164 8268

SCALE: 1/8"=1'-0"

1. Reinstall lightning protection system once roof covering and accessories are installed.

2. Roof details are located on drawing sheet A502.

3. Place roof gutter support a maximum of 36" on center. Pitch no less than 1/16" and no more than 1/8".

4. Consider which way deck slopes for best tapered layout.

5. A minimum of a 6' zone for 1/4" taper

1 New modified bitumen roofing system on rigid insulation on existing metal deck.

(see typical details sheet A502)

2 Repair opening remaining in metal deck from removal of roof drains. 2-layer 3/4" plywood extend min. 12" beyond sides of openings, when possible and anchor to metal deck.

3 New curb. See flashing detail B4 4 Reinstall existing roof exhaust. verify CFM with mechanical prior to re-installation 5 Vent stack flashing see detail C4 6 Gutter drain see detail D4. Locate highpoint of gutter with expansion joint and cover to adjacent section of gutter every 20 feet.

7 Edge flashing see detail D4. New Metal Edge covered in Manufacturer warranty, meeting ANSI-SPRI ES1 Testing. Metal Edge shall be two-piece, continuously cleated with no exposed fasteners, maximum 8" fascia length for each piece.

8 Expansion joint see detail D5. Raise expansion joint to allow 8" min. membrane flashing height. New metal cap covered in Manufacturer warranty, meeting ANSI-SPRI ES1 Testing.

9 Add roof acess ladder see elevation plan 10 Demolish soffit, fascia and support, reconstruct in accordance with detail A502/D4.

PL

AN

N O

R

TH

11 22.5 deg crickets

11 9

10 6

1 TYP

1 TYP

12 Repair roof blisters approximately 3

SQUARES.

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

3/16" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A201

A201

Exterior Demolition Elevations

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A201

Nov 2016

3/16" = 1'-0"

A101

A1 B1 South Medical Elevation

3/16" = 1'-0"

A101

A1 C1 East Medical Elevation

3/16" = 1'-0"

A101

A1 D1 Demo North Medical Elevation

3/16" = 1'-0"

A101

A1 A1 West Elevation

GENERAL NOTES

SHEET KEYNOTES

SCALE AND ORIENTATION

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

ID DATE DESCRIPTION

All items noted in RED are to be demolished or removed and supported.

1 Demolish all windows noted in elevations1 TYP 2 Remove and salvage roof exhaust.

Coordinate disposition with COR

4 Remove and dispose of roof equipment curb.

5 Existing strainer and drain assembly to be removed to top of downspout. Salvage strainer and drain assembly. Coordinate disposition with COR.

6 Existing expansion joint and blocking under coping and ply to be removed to metal roof deck.

7 Existing flashing, fascia and soffit to be removed.

9 Canopy not original construction. Assume wood assemble and reconstruction is required.

3 Remove roof membrane, crickets, insulation, flashing, etc to structural substrate.

2 TYP 3 TYP

4 TYP

5 TYP

6 TYP

7 TYP9 TYP

PL

AN

N O

A502 E2

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

3/16" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A202

A202

Exterior Proposed Elevations

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A202

Nov 2016

3/16" = 1'-0"

A104

A1 1 Proposed North Medical Elevation

3/16" = 1'-0"

A104

A1 2 Proposed West Medical Elevation

ID DATE DESCRIPTION

3/16" = 1'-0"

A104

A1 3 Proposed East Medical Elevation

3/16" = 1'-0"

A104

A1 4 Proposed South Medical Elevation

GENERAL NOTES

SHEET KEYNOTES

SCALE AND ORIENTATION

SCALE: 3/32"=1'-0"

816 16

SCALE: 3/16"=1'-0"

48 8

1. Reinstall lighting protection system once roof covering and accessories are installed.

2. Roof details are located on drawing sheet A502.

3. Place roof gutter support a maximum of 36" on center. Pitch no less than 1/16" and no more than 1/8".

1 New modified bitumen roofing system on rigid insulation on existing metal deck.

(see typical details sheet A502)

2 Repair opening remaining in metal deck from removal of roof drains. 2-layer 3/4" plywood extend min. 12" beyond sides of openings, when possible and anchor to metal deck.

3 New curb. See flashing detail B4 4 Reinstall existing roof exhaust vent verify

CFM with mechanical prior to re-installation

5 Vent stack flashing see detail C4 6 Gutter drain see detail D4. Locate highpoint of gutter with expansion joint and cover to adjacent section of gutter every 20 feet.

7 Edge flashing see detail D4. New Metal Edge covered in Manufacturer warranty, meeting ANSI-SPRI ES1 Testing. Metal Edge shall be two-piece, continuously cleated with no exposed fasteners, maximum 8" fascia length for each piece.

8 Expansion joint see detail D5. Raise expansion joint to allow 8" min. membrane flashing height. New metal cap covered in Manufacturer warranty, meeting ANSI-SPRI ES1 Testing.

9 Add roof access ladder 10 Demolish soffit, fascia and support, reconstruct in accordance with detail A502/D4.

PL

AN

N O

R

TH

1 TYP 6 TYP

10 TYP

3 TYP4 TYP 8

5 TYP

2 TYP

11 1/2" single pane laminated tinted, reflective, or low e coasted glass in an uninsulated aluminum frame

11 TYP

7 TYP

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

1/2" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A203

A203

Interior Proposed Room Elevation

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A203

Nov 2016

ID DATE DESCRIPTION

1/2" = 1'-0"

A104

A1

1 EXAM RM EAST WALL

1/2" = 1'-0"

A104

A1

2 EXAM RM NORTH WALL

1/2" = 1'-0"

A104

A1

3 EXAM RM SOUTH WALL

1/2" = 1'-0"

A104

A1

4 EXAM RM WEST WALL

1/2" = 1'-0"

A104

A1

5 LAB WEST WALL

1/2" = 1'-0"

A104

A1

6 LAB EAST WALL

1/2" = 1'-0"

A104

A1

7 LAB SOUTH WALL

SHEET KEYNOTES

SCALE

1/2 1 21

SCALE: 1"=1'-0"

1 2 42

SCALE: 1/2"=1'-0"

1 Existing examination table to be removed by contractor. Safely store for reinstallation.

2 Furniture and other equipment to be supplied by customer

3 Install privacy track for accoustical ceiling grid/tile system

4 Specimen pass through door 5 Casework in accordance with details

Sheet A504 and specification 6 Customer service window 7 Provide new medical base cabinet, sink, and wall cabinets to match existing.

8 Relocate existing return air register and ductwork to a position above and clear of wall and base cabinet.

1 TYP

2 TYP

3 TYP

4 5 TYP7

7 TYP

PROJECT NUMBER

APPROVING OFFIC

PROJ ENGR CNSTR

AVIATION TRA

MOBILE

EOH

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities E Mobi

Mr. Ron Confer Ronald.A.Con

U.S. COAS

U.S. COAST GUARD

8501 TANNER WILLIAMS

MOBILE AL 36608

FACILITIES E

ATC M

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

1/2" = 1'-0"

7088488

MAJOR M&R MED

EOH

Author

A204

Interior Proposed

EOH

NCP

LCDR P F Bos

ARCHITE

IN H

S247

ID DATE

1/2" = 1'-0"

A104

A1 D1 Pharmacy Service N Wall

1/2" = 1'-0"

A104

A1 B1 Pharmacy Service W wall

1/2" = 1'-0"

A104

A1 D5 Pharmacy Service S Wall

1/2" = 1'-0"

A104

A1 B5 Pharmacy Issue E wall

1/2" = 1'-0"

A104

A1 A1 Pharmacy Issue S Wall

1/2" = 1'-0"

A104

A1 A3 Pharmacy Issue W wall

SD

TPH

SCALE

1/2 1 21

SCALE: 1"=1'-0"

1 2 42

SCALE: 1/2"=1'-0"

1/2" = 1'-0"

A104

A1 D3 Pharmacy Service E wall

1/2" = 1'-0"

A104

A1 B3 Pharmacy Issue N Wall

SHEET KEYNOTES

1 Existing VTR 2 Rolling counter shutter unit 3 Existing Fan Coil Unit 4 Reinstall existing flourescent light fixture 5 New medical quality base cabinet and SS sink 6 Pharmacy shelving per detail sheet 7 Re-install existing smoke detector

4 TYP

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities Engineering Mobile/AL

Mr. Ron Confer: 251 441-6185 Ronald.A.Confer@uscg.mil

U.S. COAST GUARD

U.S. COAST GUARD

8501 TANNER WILLIAMS ROAD

MOBILE AL 36608

FACILITIES ENGINEERING

ATC MOBILE

SCALE:

ISSUE

DESIGNED BY:

DRAWN BY:

EDITED BY:

CHECKED BY:

1 2 3 4 5 6

A

1 2 3 4 5 6

B

C

D

E

A

B

C

D

E

SHEET OF

PLOT SCALE: D SIZE

C :\U se rs

\e vo nh \D oc um en ts

\7

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

-M aj or M

&R _M ed ic al C lin ic

S2

4) \7

-D

W G

F

IN

AL

-M aj or

M &R

_M ed ic al

C lin ic

S2 4)

.rv t

1/2" = 1'-0"

7088488

MAJOR M&R MEDICAL CLINIC (S24)

EOH

RAC

S247088488A205

A205

Interior Proposed Room Elevation 3

EOH

NCP

LCDR P F Bosma

ARCHITECTURAL

IN HOUSE

S247088488A205

Nov 2016

ID DATE DESCRIPTION

1/2" = 1'-0"

A104

A1

D1 LAB TOILET N WALL

1/2" = 1'-0"

A104

A1

D2 LAB TOILET E WALL

1/2" = 1'-0"

A104

A1

D4 LAB TOILET S WALL

MIRRPass Thru

PTD

WB

SD

TPH

1/2" = 1'-0"

A104

A1 C1 Proposed Opt 2a - S Wall

1/2" = 1'-0"

A104

A1 C2 Proposed Opt 2a - W Wall

SCALE

1/2 1 21

SCALE: 1"=1'-0"

1 2 42

SCALE: 1/2"=1'-0"

SHEET KEYNOTES

1/2" = 1'-0"

A105

A3 A1 Proposed Opt 2c - N Wall

1/2" = 1'-0"

A105

A3 A2 Proposed Opt 2c - W Wall

1/2" = 1'-0"

A105

A2 C4 Proposed Opt 2b - N Wall

1/2" = 1'-0"

A105

A2 C5 Proposed Opt 2b - W Wall

1/2" = 1'-0"

A105

A5 D5 Proposed Opt 2d - W Wall

SHEET KEYNOTES

1 Base Bid. New laboratory toilet room with paper towel and waste basket built into wall.

2 Base Bid. New laboratory toilet room specimen pass thru door.

3 Base Bid re-route laboratory toilet room exhaust and ductwork.

4 Base Bid. New toilet room aceesories as noted in elevation.

5 Base Bid. New toilet, sink and associated plumbing neceesary for fully functional facility

6 OPT 2c. Janitorial closet new mop sink.

Locate pre existing toilet drain and provide appropriate trap. Trap will be located in crawl space.

6 6

7 OPT 2c. Janitorial faucet and associarted plumbing. Connect plumbing to existing hot and cold water lines capped within plumbing wall.

8 OPT 2c. Janitorial closet. Provide supply shelving.

9 OPT 2c. Janitorial Closet. Demolish supply ductwork and diffuser. Cap duct.

10 OPT 2c. Janitorial Closet. Connect new exhaust grill and dictwork to existing exhaust ductwork.

SHEET KEYNOTES

10 10

11 OPT 2b. Dirty and Clean CSR, New medical pass thru cabinet.

11 11

12 OPT 2b. Dirty and Clean CSR. New door on existing frame

13 OPT 2c. Dental Lab. Relocate plaster trap

14 OPT 2c. Dental Lab. New medical base and wall cabinet

14 14

15 OPT 2c. Dental Lab. New SS sink.

Connect to plaster trap. Provide appropriate plumbing to make sink fully functional

15 15

16 OPT 2c. Dental Lab. New fume hood and exhaust ductwork connected to existing exhaust. Provide damper and size duct for 250 CFM. Provide 1/2" door undercut or door grill.

17 OPT 2b and 2c new tile floor

18 OPT 2d. New Xray room storage devide

DOOR AND FRAME

19 OPT 2d. New Xray room and storage room devide WALL

W14X34

W10X17

1 1/2"ø V

18K5

HSS4X0.313

W18X50

W12X26

FLR1 - 4"

Concrete Slab

Elevated

Existing Copper Vent pipe to be demolished and capped.

Existing structural column to be cased as architectural column.

New nurse station

7"

1' - 0"

W14X3418K5 1 1/2"ø V

HSS4X0.313

W10X17

Ductwork contraint for this ceiling section

8'

4" 4"

1'

6"

1'

6"

1"

1'

2"

1' - 8"

8" 3'

4"

4'

0"

A502 E1

D1 A502

A502 C1

A502 D4

DISCIPLINE/SHT NO

PROJECT NUMBER DRAWING NUMBER

APPROVING OFFICER DATE

PROJ ENGR CNSTR MGR COTR

AVIATION TRAINING CENTER

MOBILE AL

EOH NCP RAC

SHEET TITLE

SAM DESIGN P/N:

CAD FILE NAME:

Facilities…