Pier_CP_Drwgs.pdf

PDF 1 MB Posted

Attached to
INSPECT & REPAIR CATHODIC PROTECTION SYSTEMS
Solicitation number
HSCG45-15-Q-JT145
Issued by

About this file

COAST GUARD PIER DRAWINGS

View the file

Other files

File Type Posted
SOW_Inspect_and_Repair_Pier_CP_Systems.pdf PDF
05-2017_SCA_Wages.txt TXT text file
SF18_RFQ.pdf PDF
RFQ_SERVICES_Clauses.doc DOC document
RFQ_Cover_Ltr_JT145.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C E

USCG

Woodinville, WA.

RECORD

TA:-10.11

TA:-14.07

TA:-7.09

TA:-16.11

TA:-11.00

TA:-8.00

TA:-16.07

TA:-16.03

TA:-10.08

TA:-8.00

TA:-13.11

TA:-17.00

TA:-11.09

TA:-9.03

TA:-15.05

TA:-18.02

44" AML

C E

TA: -18.09

TA: -17.00

TA: -14.01

TA: -12.01

TA: -21.11

TA: -20.01

TA: -16.02

TA: -12.01

TA: -6.09

TA: -4.06

TA: -1.9

TA: -11.11 TA: -13.00 TA: -13.09 TA: -14.03 TA: -14.09

6x6 TS W/ 2 ANODES

18'-9 3/4"

TA: -20.02

TA: -16.06TA: -15.02

TA: -19.09

TA: -11.08TA: -12.04

TA: -6.05TA: -7.06

TA: -0.02TA: -4.06

NINI

NINI

TA: -5.19

TA: -0.04

44" AML/ SP

48" AML/ SP

12" AML/ SP 44" AML/ SP

TA: -3.2

6x6 TS W/ 2 ANODES

19'-0 1/4"

TA: -3.11 TA: -5.11

TA: -17.08TA: -16.06

TA: -3.11TA: -12.07

TA: -10.03TA: -7.09

TA: -3.05TA: -2.00

TA: -19.09

TA: -20.00

TA: -4.63

TA: -2.11

6x6 TS W/ 2 ANODES

18'-9"

TA: +0.89

6x6 TS W/ 2 ANODES

TA: -3.70

6x6 TS W/ 2 ANODES

19'-1 3/4"

TA: 0.00

6x6 TS W/ 2 ANODES

19'-0"

TA: -0.09

TA: -1.92

6x6 TS W/ 2 ANODES

18'-9 1/8"

NI

NI NI

TA: -20.06TA: -20.07

TA: -19.07TA: -18.08

TA: -16.01TA: -14.02

TA: -12.06TA: -9.03

TA: -20.09

TA: -20.06

48" AML

TA: -7.11TA: -5.01

TA: -4.08TA: -1.11

TA: -0.08TA: +2.96

20" AML/ SP12" AML

12" AML 32" AML/ SP

TA: -1.19

6" AML

TA: -5.01

TA: -9.06

TA: -12.06

TA: -20.02

TA: -19.09

TA: -7.11

TA: -15.09

TA: -21.01

C E

TA: -16.04 TA: -15.07 TA: -16.04

TA: -11.09

TA: -7.09 TA: -8.06

TA: -12.01 TA: -13.06

48" AML /

ROCK

TA: -9.07

TA: -20.00

70" AML/ SP

TA: -12.03 TA: -11.08

TA: -16.07

TA: -19.06

49" AML/ SP

TA: -9.00

TA: -4.05

30" AML/ SP

TA: +2.91

24" AML/ SP

TA: -1.15

6" AML

TA: +1.99

18" AML

19'-0"

6x6 TS W/ 2 ANODES

TA: -3.25

TA: +1.99

TA: -3.11 TA: -1.07

16" AML/ SP

TA: -4.60

6" AML

TA: -6.09

40" AML/ SP

TA: -16.00 TA: -16.11

TA: -6.05

TA: -11.07 TA: -13.01

TA: -6.07

TA: -12.11 TA: -2.11

TA: -17.06

TA: -8.08

TA: -16.06

TA: -8.01

TA: -16.05 TA: -16.11

TA: -10.06 TA: -9.05

18" AML/ SP

60" AML /

ROCK

TA: -8.11

TA: -4.00

18" AML/ SP

TA: +2.97

2" AML

TA: +2.55

2" AML

6" AML

18'-11 7/8"

6x6 TS W/ 2 ANODES

TA: -6.04

19'-1 3/4"

6x6 TS W/ 2 ANODES

TA: -8.20

32" AML/ SP

16" AML/ SP

C E

USCG

TA: -10.06 TA: -11.03

TA: -15.06 TA: -14.09

TA: -10.11

TA: -5.08

TA: -4.09

TA: +0.93

TA: -7.03 TA: -7.09

24" AML/ SP

C E

C E

ANODE SLED ASSEMBLY PILE ANODE INSTALLATION CABLE GUARD BOND BOX

SITE PLAN

C E

USCG

C E

USCG

John F. Keppler No. CE10532

NOTES:

1.

2.

3.

4.

C E

USCG

John F. Keppler No. CE10532

File details come from the government source that posted it. Updated .