A00002_HSCG40-15-Q-P30035_(Page_2).pdf
PDF 141 KB Posted
- Attached to
- USCG ANT COLFAX (ANB 643503) 2015 DRYDOCK REPAIR
- Solicitation number
- HSCG40-15-Q-P30035
About this file
A00002 (page 2 of 2)
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HSCG40-15-Q-P30035
Amendment Number A00002
14A. This Amendment is issued to answer the following questions submitted in response to this solicitation:
QUESTION: Work Item 3 does not designate which void in Table 1. Can not determine by any other reference in the WI. Is this a no bid item?
ANSWER: Table one should read Pipe Fender, Fairleads and Transducers Fore and Aft.
QUESTION: How should KTR to price D-001; 1 JOB? The page 16, specification in para 3.3. calls out for 4 different types of work effort, each would have a different cost associated. Please advise.
ANSWER: Break down bid for the 4 different types of work. Bid each one per 3.3
QUESTION: WI 17 Title Fuel Valves, Overhaul or Renew, however the valves addressed in 1.1.1 and 1.1.2 are bilge suction valve and suction gage valve not fuel valves. Is the title wrong or the valves listed incorrect?
ANSWER: The fuel valves for renewal are: TYPE SIZE
(inches) MATERIAL DESCRIPTION FRAME LOCATION/VALVE
NO. CONNECTION RATED PRESSURE CLASS (#)
Globe 1/2 Bronze Suction Gage C/O 2-14-2 Welded 50
Gate 3/4 Bronze Fuel Supply Threaded
Ball 1/2 Bronze Fuel Return Threaded
Gate 1/2 Bronze Stripping Threaded
14B. The date and time established for receipt of proposals remains November 21, 2014 at 12:00 PM EST.
(END OF AMENDMENT NUMBER A00002)