Page 2 of Amendment 0002
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_0005_to_HSCG40-12-R-AG030.pdf | ||
| Amendment_4-_RFP_AG030.pdf | ||
| Amendment_4-_final_ag030.pdf | ||
| SF30Amendment_0003_to_HSCG40-12-R-AG030.pdf | ||
| REVISED_Amendment__0001.pdf | ||
| REVISED_Amendment__0002.pdf | ||
| Specification_for_Pump_Overhaul_R-503-0519.docx | DOCX document | |
| SF30_-_Amendment_2_HSCG40-12-R-AG030.pdf | ||
| SF30_-Amendment_1__HSCG40-12-R-AG030.pdf | ||
| PUMPS_SOL_AG030.doc | DOC document | |
| Final _Various_Pump_Overhaul_R-503-0519.docx | DOCX document | |
| PUMPS_SOL_AG030.doc | DOC document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STANDARD FORM 30 (Continued)
FAR (48 CFR) 53.243 Page of
CONTINUATION SHEET
AMENDMENT OF SOLICITATION
AMENDMENT NO. 0002 DATE:
TO SOLICITATION: HSCG40-12-R-AG030
BLOCK 14. Continuation of Description of Amendment:
The above referenced solicitation, Request for Proposals (RFP) HSCG40-12-R-AG030, is modified to reflect the following changes:
1. RFP - CLINS 0002, 1002, 2002, 3002, and 4002 are changed to reflect the Item Name to read Pump in lieu of Pump Unit.
2. Specification R-503-0519, Work Item 2 is changed to reflect the Item Name to read Pump in lieu of Pump Unit.
3. RFP - CLINS 0008, 1008, 2008, 3008, and 4008 are changed to reflect the Item Name to read Pump Unit in lieu of Pump.
4. Specification R-503-0519, Work Item 8 is changed to reflect the Item Name to read Pump Unit in lieu of Pump.
5. Page 5 of the RFP, Government Furnished Property - Work Item 15, the Item Name is changed to read Pump in lieu of Pump Unit.
6. Page 5 of the RFP, Government Furnished Property - Work Item 22, the Item Name is changed to read Pump in lieu of Punp Unit.
7. RFP - CLINS 0025, 1025, 2025, 3025, and 4025 are changed to reflect the Item Name to read Pump Unit in lieu of Pump.
8. Page 90 of the RFP, change Total of Base Year Requirements to read Total of Option Year 1 Requirements, for both mandatory and contingency parts totals.
9.Page 131of the RFP, change Total of Base Year Requirements to read Total of Option Year 2 Requirements, for both mandatory and contingency parts totals.
10.Page 172 of the RFP, change Total of Base Year Requirements to read Total of Option Year 3 Requirements, for both mandatory and contingency parts totals.
11. Page 213 of the RFP, change Total of Base Year Requirements to read Total of Option Year 4 Requirements, for both mandatory and contingency parts totals.
STANDARD FORM 30 (Continued)
FAR (48 CFR) 53.243 Page of
CONTINUATION SHEET
AMENDMENT OF SOLICITATION
AMENDMENT NO. 0002 DATE:
TO SOLICITATION: HSCG40-12-R-AG030
BLOCK 14. Continuation of Description of Amendment:
12. Paragraph 3.2.2. of Specification R-503-0519 is changed to read: Zerc fittings/Fasteners and requires all carbon steel fasteners in S/W application pumps to be replaced with austenitic stainless steel fasteners.
13. Clarification of Paragraph 3.21.4 of Specification R-503-0519 is provided: Desiccant is not being required to be placed inside the discharge flange; therefore, removal prior to operation is not required and warning labels are not necessary. No change has been made to the Paragraph itself.
14. Work Items 1, 3, 4, 5, 6, and 7 of Specification R-503-0519 have been changed to reflect the requirement for Pipe Plugs, mandatory or contingency parts, to be Stainless Steel commercial equivalent.
15. The P/N requirement for Pipe Plugs, mandatory or contingency parts, has been changed to read Stainless Steel equivalent; therefore, the following CLINS in the RFP have been changed accordingly:
CLIN 0001, 1001, 2001, 3001, 4001
CLIN 0003, 1003, 2003, 3003, 4003
CLIN 0004, 1004, 2004, 3004, 4004
CLIN 0005, 1005, 2005, 3005, 4005
CLIN 0006, 1006, 2006, 3006, 4006
CLIN 0007, 1007, 2007, 3007, 4007
16. Work Item 6 of Specification R-503-0519; move P/N 813002-61, Cap, Vent from Contingency Parts List to Mandatory Parts.
17. RFP- CLINS 0006, 1006, 2006, 3006, and 4006 are changed to move P/N 813002-61, Cap, Vent from Contingency Parts List to Mandatory Parts.
18. Work Item 3 of Specification R-503-0519; Mandatory Replacement Parts, change P/N 7602670090 and 702500090 to each read P/N SKF CRW1 “R” Series, Dual Lip Oil Seal.
19. RFP - CLINS 0003, 1003, 2003, 3003, and 4003, Mandatory Replacement Parts, 7602670090 and 702500090 are changed to read P/N SKF CRW1 “R” Series, Dual Lip Oil Seal.
20. Work Item 4 of Specification R-503-0519; Mandatory Replacement Parts, change P/N 0702370090 and 0702440090 to read P/N SKF CRW1 “R” Series, Dual Lip Oil Seal.
STANDARD FORM 30 (Continued)
FAR (48 CFR) 53.243 Page of
CONTINUATION SHEET
AMENDMENT OF SOLICITATION
AMENDMENT NO. 0002 DATE:
TO SOLICITATION: HSCG40-12-R-AG030
BLOCK 14. Continuation of Description of Amendment:
21. RFP - CLINS 0004, 1004, 2004, 3004, and 4004, Mandatory Replacement Parts, change P/N 0702370090 and 0702440090 to read P/N SKF CRW1 “R” Series, Dual Lip Oil Seal.
22. Work Item 7 of Specification R-503-0519; Mandatory Replacement Parts, change P/N 072380090 and 070244090 to read P/N SKF CRW1 “R” Series, Dual Lip Oil Seal.
23. Work Item 7 of Specification R-503-0519; move P/N 2300210021 and P/N 2300470021 from Mandatory Replacement Parts to Contingency Parts List.
24. RFP - CLINS 0007, 1007, 2007, 3007, and 4007, Mandatory Replacement Parts, change P/N 0702380090 and 0702420090 to read P/N SKF CRW1 “R” Series, Dual Lip Oil Seal.
25. RFP - CLINS 0007, 1007, 2007, 3007, and 4007, move P/N 2300210021 and P/N 2300470021 from Mandatory Replacement Parts to Contingency Parts List.
26. Page ix of Specification R-503-0519; the following changes have been made:
Paragraph 3.19 – The paragraph has been modified to include the wording “oil”.
Paragraph 3.21.1 – The Mil-Spec reference has been corrected to read MIL-PRF-81903F.
Paragraph 3.21.4 – The paragraph has been modified to include Type I for MIL-D-3464E Desiccant.
27. Clarification of Paragraph 3.21.2 of Specification R-503-0519 is provided: It is not the intention of “all unpainted surfaces” to include non-ferrous pump components.
28. Page ii of Specification R-503-0519, Work Item 15 is changed to read Pump in lieu of Pump Unit.
29. Page ii of Specification R-503-0519, Work Item 22 is changed to read Pump in lieu of Pump Unit.