HSC 147th BSB Storage Lockers_SOW.docx
DOCX document 30 KB Posted
- Attached to
- Storage Lockers - Amendment 03
- Solicitation number
- W912LC26Q0035
About this file
This is a Statement of Work (SOW) for the procurement and installation of organizational clothing and individual equipment (OCIE) storage lockers at the Fort Collins Readiness Center in Colorado. The HSC 147th Brigade Support Battalion requires 60 individual lockable storage units configured as 20 relocatable towers, stacked three tiers high, to comply with The Adjutant General's storage policy. The contractor shall provide turnkey service including unboxing, assembly, multi-tier configuration, and safety stabilization, with all on-site work to be completed within 60 days of contract award.
The lockers must feature non-reflective matte Olive Drab Green or matte black powder coat finish, diamond perforated doors for ventilation and visibility, heavy-duty hasps compatible with standard padlocks, and sequential numbering for tactical tracking. Each stack must measure 30"W x 36"D x 84"H to 90"H and be self-supporting and wall-secured without structural facility modifications. Delivery is required Tuesday through Friday, 0730-1600 hours, to 3324 Laporte Avenue, Fort Collins, CO 80521. The solicitation (W912LC26Q0035) includes two CLINs: CLIN 0001 covers the 60 steel storage lockers (60 EA), and CLIN 0002 covers installation and shipping (1 EA). Payment will be processed through Wide Area Workflow (WAWF) upon customer acceptance at installation and invoice submission. The contracting agency is the Department of the Army Colorado Army National Guard.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Solicitation - W912LC-26 Q-0035-Amendment 3.pdf | ||
| HSC 147th BSB Storage Lockers_SOW_Amendment 03.pdf | ||
| W912LC-26-Q-0035-03 Amendment Questions_Answers.pdf | ||
| HSC 147th BSB Storage Lockers_SOW_Amendment 02.docx | DOCX document | |
| TA1.jpg | JPG image | |
| TA3.jpg | JPG image | |
| Combined Synopsis Solicitation - W912LC-26 Q-0035-Amendment 2.docx | DOCX document | |
| TA2.jpg | JPG image | |
| HSC 147th BSB Storage Lockers_SOW_Amendment 01.docx | DOCX document | |
| Combined Synopsis Solicitation - W912LC-26 Q-0035.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Product Description (PD) Title-OCIE Locker Storage for Fort Collins Readiness Center SSC-154-136841
Purpose Statement / Objective – HSC 147th Brigade Support Battalion (BSB) requires lockers for Organizational Clothing and Individual Equipment (OCIE) storage to comply with The Adjutant General’s policy regarding the storage of every Soldier’s OCIE at their respective unit’s armory.
Scope – The contractor shall provide all required personnel, equipment, tools, materials, supervision, and quality control necessary to perform the installation of 20 relocatable personal locker towers (60 lockers total).
For supplies enter delivery address – The supplies will be delivered to the Fort Collins Readiness Center as the lockers will be installed at this location.
HSC 147th BSB only accepts deliveries Tuesday - Friday from 0730-1600. Closed on Mondays.
HSC 147th BSB 3324 Laporte Avenue, Fort Collins, CO 80521
Point of Contact: SSG Georgia Knapp – (928) 991-3692 Alternate Point of Contact: SFC Alec Huddy – (520) 942-5553 To ensure timely payment, please follow instructions below.
Supplier compliance instructions for adequate shipping / receiving:
· Place all shipping labels on the OUTSIDE of the container,
· Mark all containers appropriately (i.e., 1 of 1, 1 of 2, etc.),
· Include contract number (s) on shipping label,
· Include any item descriptions necessary for proper identification, and Salient Characteristics:
(A) Functions to be performed; Assembly and installation of relocatable, individual lockers.
(B) Essential physical characteristics;
1. Finish: Non-reflective, matte Olive Drab (OD) Green or matte black durable texture powder coat paint.
2. Locker doors shall have a diamond perforated design or similar for maximum ventilation and visibility.
3. Configuration: Modular, stackable design, configured three (3) tiers high.
4. Quantity: Sixty (60) individual lockable units, in 20 stacks of 3 lockers each.
5. Security: Equipped with heavy-duty hasps/latches compatible with standard external padlock for security.
6. Identification: Individual units must be sequentially numbered for tactical tracking and assignment.
7. Dimensions: Each stack of three lockers must be 30”W x 36”D x 84”H to 90”H, installed, single file on a 50’ wall.
8. Footprint: Self-supporting, relocatable units placed directly onto the existing floor surface, secured to wall to prevent tipping
9. Constraints: Zero (0) structural modifications to the existing facility are permitted.
10. Vendor Responsibilities: Turnkey delivery including unboxing, assembly, multi-tier configuration, and safety stabilization/anchoring of the completed system.
11. Performance Window: Execution of on-site services must commence and be completed with 60 days of contract award CLIN 0001: All Steel Storage Lockers Quantity: 60 EA,total lockers, stacked 3 tiers high, for a total of 20 towers (3ea lockers per tower) in accordance with the salient characteristics
CLIN 0002: Installation/Shipping Quantity: 1 EA
Acceptance – Acceptance will be completed at installation by the customer and again upon submission of a proper invoice in Wide Area Workflow.
Payment–Payment terms and schedule etc.
· Vendor/Contractor must Invoice through Wide Area Workflow (WAWF)
· Vendor must be registered in WAWF in order to submit an invoice
· https://piee.eb.mil/
File details come from the government source that posted it. Updated .