HRF Cubicle Installation Spec.pdf
PDF 69 KB Posted
- Attached to
- Workstations to include Installation
- Solicitation number
- W912L8-24-Q-0036
About this file
This document is a Request for Proposal (RFP) for the installation of a 32-station cubicle area with a conference area at the Dunbar Armory in Dunbar, West Virginia. The scope of work requires the contractor to field verify measurements, provide and install the cubicle workstations and conference area, and dispose of excess materials. The cubicle workstations must meet specific requirements for panel height, aisle width, materials, and furnishings. The conference cubicle must include a conference table, chairs, and a laminate door panel. The project must be completed by September 30, 2024. This opportunity is being issued by the United States Property Fiscal Office on behalf of the West Virginia Army National Guard. Responses will be evaluated on a lowest priced technically acceptable basis.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Cubicle Placement.pdf | ||
| RFQ Workstations.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The scope of work for this project is to provide and install a 32-station cubicle area with conference area at Dunbar Armory located at 605 26th St Dunbar, WV. The requirements for this project are as follows:
Work to be performed:
1. Field verify measurements of existing area.
2. Provide and install a 32-station cubicle area complete with conference area and 31 equally sized stations, evenly spaced per attached layout. (Delivery & Installation must be complete on or before 30 September 2024)
3. Cubical workstation panels shall be 66” H.
4. Conference cubicle panels shall be 72” H.
5. Provide 4’ isles between cubicle units.
6. Cubicle interior panels shall have fabric on upper portion with metal trim.
7. Cubicle exterior and below work surface shall be laminate with metal trim.
8. Each cubicle workstation (excluding conference cubicle) shall be furnished with the following:
a. 1 – Wardrobe tower
b. 2 – 36” overhead storage bins w/laminate door
c. 1- Metal mobile box file pedestal
d. 1- 24”D x 48”W x 72”W square shoe work surface
e. 1 – Midback task chair
9. Conference cubicle shall be furnished with the following:
a. 1- Conference table to allow seating for 10
b. 10 – Midback task chair
c. 1 – Laminate door panel
10. Installers will use un-upholstered poly connector pieces on all 2-way & 3-way points that have laminate panels with metal trim.
11. All Fabric panels will use upholstered 2-way & 3-way connectors.
12. Installers to install panels 4” off of wall.
13. Electrical connections will be a universal 10-wire 622 system. (Green UL Labels)
14. Dispose of excess materials offsite.
File details come from the government source that posted it. Updated .