HR001123S0036_HOTS_FAQ_6-5-23.pdf
PDF 91 KB Posted
- Attached to
- High Operational Temperature Sensors (HOTS) Federal contract opportunity
- Solicitation number
- HR001123S0036
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| HR001123S0036-Amendment-03.pdf | ||
| HR001123S0036_HOTS_FAQ_8-2-23_update.pdf | ||
| HR001123S0036-Amendment-02.pdf | ||
| HR001123S0036-Amendment-01.pdf | ||
| HR001123S0036_HOTS_PM_Change_7.14.23.pdf | ||
| HR001123S0036_HOTS_FAQ_7-13-23_update_2.pdf | ||
| HR001123S0036_HOTS_FAQ_6-15-23_update_1.pdf | ||
| HR001123S0036_HOTS_Proposers_Day_Briefs.pdf | ||
| HR001123S0036.pdf | ||
| HR001123S0036_Attachment_4_OT_Certs_Template.docx | DOCX document | |
| HR001123S0036_Attachment_1_Cost_Volume_Proposer_Checklist.pdf | ||
| HR001122S0036_Attachment_2_Proposal_Summary_Chart_HOTS_v1.pptx | PPTX presentation | |
| HR001123S0036_Attachment_5_DARPA_Standard_Cost_Proposal_Spreadsheet.xlsx | XLSX spreadsheet | |
| HR001123S0036_Attachment_3_General_MTO_Controlled_Unclassified_Information_Guide__CUIG_.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
High Operational Temperature Sensors (HOTS)
HR001123S00236
Frequently Asked Questions (FAQs)
Updated on 6/5/2023
Question 1: What is the anticipated funding level?
Answer 1: Funding requests should based on cost realism as outlined in Section V.A in the
BAA.
Question 2: Is there an envisioned number of performers?
Answer 2: No
Question 3: Can Subcontractors be on multiple teams?
Answer 3: Yes
Question 4: What evaluation testing will be done?
Answer 4: Proposers should outline technical tasks regarding developing test plan and capability to demonstrate meeting or exceeding all metrics in Table 2 as stated in the page
11 BAA.
Question 5: What is the test environment?
Answer 5: See BAA, Table 2, note 1 for test environment details.
Question 6: Are abstracts considered non-binding?
Answer 6: Yes, abstracts are non-binding (including rough-order-of-magnitude cost estimates).
Question 7: Why is the pressure sensor dynamic range 90 dB?
Answer 7: This value was determined to represent the intersection of technology and impact.
Question 8: What is the timeline for Phase 1 hardware deliverables?
Answer 8: The delivered hardware will be submitted to the IV&V team one quarter before the conclusion of each phase. See BAA Section I.F
Question 9: What is the pressure range of interest?
Answer 9: See BAA, Table 2, Linear pressure metric and note 6 for details.
Question 10: How about other components (resistors, capacitors, inductors)?
Answer 10: We require a full high-temperature sensor solution that operates at 800 °C .
- If other off-chip components are required for the sensor module to achieve metrics, then describe this in proposal.
- If other off-chip components are required for the packaged sensor demonstrator, discuss and assess the risk to realizing the packaged sensor demonstrator.
Question 11: What is the lowest operating temperature?
Answer 11: The lowest operating temperature is not required in this BAA.
Question 12: Are there any supply voltage or current requirements?
Answer 12: There is no formal requirement. It is recommended that performers apply reasonability to voltage and current requirements for their proposed sensor module to maximize technology transition opportunities.
Question 13: Is the +/-10% voltage threshold variability referring to manufacturing variability or variation over temperature range?
Answer 13: The +/- 10% variability is a manufacturing metric measured over the size scale of the sensor module proposed.
Question 14: Can a performer propose to overcome just one technical challenge?
Answer 14: No
Question 15: Is there an opportunity to propose alternative sensors to pressure sensors?
Answer 15: No. Proposed solutions must meet or exceed the metrics of the program, which are based on pressure sensors as request in Table 2 of BAA. Proposers can describe their vision of alternative sensors for potential Phase 3 program expansion, as outlined in the BAA.
Question 16: Are mixed signal processing electronics considered or analog only?
Answer 16: HOTS BAA calls for a technology development and demonstration of a pressure sensor module (i.e., integrated transducer and signal-conditioning microelectronics) achieving the program metrics. Depending on proposed approaches, analog and/or mixed signal processing electronics can be considered if necessary for the specific approach to meet program metrics.
Question 17: How does DARPA foresee addressing the supply chain for the raw materials in the transducers and circuits?
Answer 17: Issues of supply chain for materials and equipment are the responsibility of the performer and should be clearly stated in their proposal.
Question 18: How can you go from the independent transducer measurements to the simulated sensor performance?
Answer 18: It is the responsibility of the individual performer to propose their method for demonstrating that they have achieved program metrics.
Question 19: Will DoD operational impact information be provided to performers?
Answer 19: No additional information will be provided outside of the BAA.
Question 20: Is the HOTS program tied to any specific US or foreign government agency or organization?
Answer 20: No.
Question 21: Would a passive sensor interrogated by remote electronics via wireless or optical fiber be an acceptable solution to HOTS?
Answer 21: No. Each proposal must demonstrate how they will overcome the technical challenges outlined in the BAA. As such, the integrated sensor and transistor circuit must be mutually contained in a single element and exposed to a common temperature.
Question 22: Can an internal or external circuit or look-up table be used to compensate temperature sensitivity of the sensor readout when the device is operating at high temperatures?
Answer 22: Yes, as long as the sensor meets the metrics of the program and the results are repeatable.
Question 23: Is there any interest in intermediate sensor system performance values while ramping temperature up to the 800 °C measurement value?
Answer 23: The Government IV&V will not formally evaluate temperature ramping effects in assessing the performance of the device under test in Phase 1 and 2; however, performers may use information from the temperature ramping for their own internal performance assessments and design considerations as they consider concepts for sensor demonstrates in a potential Phase 3 expansion.
Question 24: Can a Technical Challenge be deferred to later in the program, such as in Phase 2?
Answer 24: No. As stated on p. 10 of the BAA "All submitted proposals are expected to address the sensor goals and all three Technical Challenges described in the above Section B of this solicitation throughout all phases of HOTS"