Hot bonder spec sheet.docx
DOCX document 973 KB Posted
- Attached to
- 359 TRS Hot Bonders FY25
- Solicitation number
- F3V5D44339AW01
About this file
This is a technical specification sheet for the HB-2 Dual Zone Composite Repair System, which is being procured through a brand name only solicitation for the 359 TRS at Pensacola, FL. The system specifications include dual programmable heating zones, operating temperatures up to 1000°F, 16 thermocouple inputs, dual vacuum lines, and auto-switching power supply (85-265 volts). The unit weighs 45 pounds and has dimensions of 21" x 14" x 8" with NSN 4920-01-445-4529.
The Department of the Air Force Air Education and Training Command (82d Contracting Squadron) is seeking to procure 2 Wichitech Dual Zone Hot Bonders (Part Number F4HB2005) through a Firm Fixed Price contract. This is a small business set-aside under NAICS code 336413 (size standard 1,250 employees). Quotes are due by 02:00PM CST on February 7, 2025, with questions due by February 4, 2025. The solicitation number is F3V5D44339AW01, and quotes must remain valid for 90 days after closing.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CLSExport_FA302025Q0008.pdf | ||
| Hot Bonders FY25_Combo.pdf | ||
| BNJ Letter_Signed.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HB-2 Dual Zone Composite Repair System
| Items | HB-2 Dual Zone Composite Repair System |
| Weight | 45 Pound |
| NSN | 4920-01-445-4529 |
| Model | HB2005 |
| Heating Zones | 2- Operator Programmable |
| Heating System | Electric Blanket, Heat Lamps, Heat Gun |
| Heat/Dwell Steps | 1 to 6 |
| Heat Up Rate | 1º to 15º in 1º increments °F/minute |
| Dwell Temperature | 1000 ºF |
| Dwell Time | 0 to 999 minutes per step |
| Cool Down Rate | 1º to 15º F/minute in 1º increments |
| Temperature Accuracy | ±5 ºF |
| Heat Blankets | 8" x 8", 10" x 10" Standard |
Thermocouple
| Active Thermocouple Inputs | 16 (Control and Backup) 8 Per Zone (10 optional) |
| Vacuum Pump (Standard) | Oil-Free, Electric, 0.90 CFM (Dual Head) |
External Vacuum
| Vacuum Lines | 2 with thru-bag connector; 10' hose standard; 20' hose optional |
| Active Vacuum Transducers | 2 (0" to 30" Hg) |
| Alarm Conditions | Low Vacuum, Open Thermocouple, Over Temperature, Under Temperature, TC Fall (Declining Temperature), Blanket Control Failure (No Heat) |
| AC Power Supply | Auto-switching 85-265 volts, 47-440 Hz, 20 Amp |
| AC Safety Devices | Circuit breaker - 20 Amp; Ground fault circuit interrupter |
| Size | 21" x 14" x 8" |
image1.png