Hot bonder spec sheet.docx

DOCX document 973 KB Posted

Attached to
359 TRS Hot Bonders FY25
Solicitation number
F3V5D44339AW01
Issued by

About this file

This is a technical specification sheet for the HB-2 Dual Zone Composite Repair System, which is being procured through a brand name only solicitation for the 359 TRS at Pensacola, FL. The system specifications include dual programmable heating zones, operating temperatures up to 1000°F, 16 thermocouple inputs, dual vacuum lines, and auto-switching power supply (85-265 volts). The unit weighs 45 pounds and has dimensions of 21" x 14" x 8" with NSN 4920-01-445-4529.

The Department of the Air Force Air Education and Training Command (82d Contracting Squadron) is seeking to procure 2 Wichitech Dual Zone Hot Bonders (Part Number F4HB2005) through a Firm Fixed Price contract. This is a small business set-aside under NAICS code 336413 (size standard 1,250 employees). Quotes are due by 02:00PM CST on February 7, 2025, with questions due by February 4, 2025. The solicitation number is F3V5D44339AW01, and quotes must remain valid for 90 days after closing.

View the file

Other files

File Type Posted
CLSExport_FA302025Q0008.pdf PDF
Hot Bonders FY25_Combo.pdf PDF
BNJ Letter_Signed.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HB-2 Dual Zone Composite Repair System

ItemsHB-2 Dual Zone Composite Repair System
Weight45 Pound
NSN4920-01-445-4529
ModelHB2005
Heating Zones2- Operator Programmable
Heating SystemElectric Blanket, Heat Lamps, Heat Gun
Heat/Dwell Steps1 to 6
Heat Up Rate1º to 15º in 1º increments °F/minute
Dwell Temperature1000 ºF
Dwell Time0 to 999 minutes per step
Cool Down Rate1º to 15º F/minute in 1º increments
Temperature Accuracy±5 ºF
Heat Blankets8" x 8", 10" x 10" Standard

Thermocouple

Active Thermocouple Inputs16 (Control and Backup) 8 Per Zone (10 optional)
Vacuum Pump (Standard)Oil-Free, Electric, 0.90 CFM (Dual Head)

External Vacuum

Vacuum Lines2 with thru-bag connector; 10' hose standard; 20' hose optional
Active Vacuum Transducers2 (0" to 30" Hg)
Alarm ConditionsLow Vacuum, Open Thermocouple, Over Temperature, Under Temperature, TC Fall (Declining Temperature), Blanket Control Failure (No Heat)
AC Power SupplyAuto-switching 85-265 volts, 47-440 Hz, 20 Amp
AC Safety DevicesCircuit breaker - 20 Amp; Ground fault circuit interrupter
Size21" x 14" x 8"

image1.png

File details come from the government source that posted it. Updated .