High School Locker Replacement.pdf

PDF 275 KB Posted

Attached to
High School metal locker replacement
Solicitation number
RFP-DKS-190000002902-1
Issued by
Baraga County, Michigan

About this file

This document is a detailed specification for a metal locker replacement project for Delton Kellogg High School, located in Delton, Michigan. The project, identified as A/E Project 5-4900, involves furnishing and installing steel lockers in various areas of the school, including athletic and physical education locker rooms. The specification provides comprehensive requirements for locker materials, fabrication, and installation, with a focus on single-tier lockers in 15"w x 15"d x 72"h and 10"w x 15"d x 72"h configurations. The lockers will be heavy-duty ventilated type from approved manufacturers such as Republic Storage Systems, Lyon Metal Products, Penco Products, and others.

The specification outlines detailed technical requirements for the lockers, including material composition (mild cold rolled sheet steel), finish (phosphatized and enamel-coated), and specific design elements like 18-gauge tops, 5-knuckle hinges, number plates, interior hooks, and a sophisticated locking mechanism. The project includes provisions for accessibility, requiring a minimum of 5% accessible lockers dispersed throughout the installation. The lockers come with a minimum two-year warranty against defects, and the installation will be performed on existing bases and in the locations of current lockers. The specification provides extensive details on construction, finish, and performance expectations to ensure a high-quality replacement of the school's existing locker infrastructure.

View the file

Other files

File Type Posted
High School Locker Replacement (1).pdf PDF
High School Air Conditiong and Lockers.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OWNER

GMB Project #

Printed On Recycled Paper

VICINITY MAP

DELTON KELLOGG SCHOOLS

327 N. GROVE ST, DELTON, MI 49046

P. 269.623.1500 www.dkschools.org

MAP BY GOOGLE

GMB

ARCHITECT + ENGINEER

ARCHITECTURE + ENGINEERING

85 East Eighth Street, Suite 200, Holland, MI 49423 P. 616.796.0200 F. 616.796.0201 www.gmb.com

C :\L oc al

P ro je ct s\ 5-

A

_C

EN

TR

AL

_e rin m

.rv t

DELTON KELLOGG HIGH SCHOOL

DELTON KELLOGG SCHOOLS

DELTON, MICHIGAN

5-4900

10425 PANTHER PRIDE

ARCHITECTURAL

A2.1A UNIT 'A' FIRST FLOOR PLAN

06.10.2019

BIDS & CONSTRUCTION

11 11

15 17

15 17

9 9 9 9

26 11

26 11

ATHLETICS

PT

OFFICE

PT

OFFICE

PT

OFFICE

PT

PE

PT

ATHLETICS

PT

OFFICE

PT

PE

PT

NOTE: CONTRACTOR TO FIELD

MEASURE ALL LOCATIONS AND

VERIFY EXISTING CONDITIONS.

REUSE EXISTING BASES.

A2.1A

Sim

NEW BASE

A2.1A

Sim

A2.1A

Sim

A2.1A

SimNEW BASE

NE

W

B

AS

E

NE

W

B

AS

E

NEW BASE

NE

W

B

AS

E

A2.1A

Sim

A2.1A

Sim

3/4" PLYWOOD x 4" WIDE

CONTINUOUS AT LOCKER

ANCHOR POINT BY LOCKER

CONTRACTOR IF REQUIRED

METAL LOCKER - SEE

SPECIFICATIONS

RUBBER WALL BASE

LOCKER TOP - SEE

SPECIFICATIONS

1/2" PLYWOOD ANCHORED TO

2x4 TREATED WOOD BASE SECURED TO 2x4 P.T. FRAMING

AT 24" O.C. (LAID FLAT) AND ANCHORED WITH

(2) 1/2" DIA. EXP. ANCHORS PER BOARD

LO

CK

ER

H

EI

GH

T

SE

E

SP

EC

IF

. F

OR

4"

GENERAL FLOOR PLAN NOTES:

1. DIMENSIONS GIVEN ARE TO THE FACE OF MASONRY UNITS OR TO THE FINISHED FACE OF METAL STUD PARTITION WALLS.

2. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.

3. PROVIDE PAINTED ACCESS PANELS IN WALLS AND CEILINGS TO PROVIDE ACCESS TO CONCEALED ITEMS INCLUDING BUT NOT LIMITED TO VALVES, CONTROLS, MECH. EQUIPMENT ETC. ACCESS PANELS MAY NOT ALWAYS BE SHOWN ON PLANS. IT IS THE SUB CONTRACTOR RESPONSIBILITY TO DETERMINE LOCATIONS. COORDINATE LOCATIONS WITH OTHER GENERAL

CONTRACTOR / SITE SUPERVISOR.

4. CONTRACTOR TO MAINTAIN / REPAIR RATING OF EXISTING PARTITIONS AS AFFECTED BY DEMOLITION / NEW

CONSTRUCTION. TYPICAL THROUGHOUT.

5. WALLS TO BE PATCHED WITH LIKE MATERIALS WHERE EXISTING WALLS HAVE BEEN COMPROMISED FROM DEMOLITION. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVAL AND REINSTALLATION OF CASEWORK AND WALL MOUNTED EQUIPMENT IN ORDER TO ACHIEVE SAID PATCH. IN AREAS WHERE BLOCK OR BRICK HAVE BEEN USED, NEW MASONRY TO BE TOOTHED IN AND MATCH EXISTING. AREAS AND FINISHES IN QUESTION SHALL BE COORDINATED WITH

ARCHITECT.

PT = PAINT

PROJECT NO.

DRAWN

REVIEWED

GMB

No part of this drawing may be used or reproduced in any form or by any means, or stored in a database or retrieval system, without prior written permission of

Copyright 2019 All Rights Reservedc

ARCHITECTURE + ENGINEERING

85 East Eighth Street, Suite 200

P. 616.796.0200 F. 616.796.0201

HOLLAND LAB

www.gmb.com

Holland, Michigan 49423

648 Monroe Avenue, N.W. Suite 500

GRAND RAPIDS LAB

Grand Rapids, Michigan 49503

310 North Alabama Street, Suite 230

INDIANAPOLIS LAB

Indianapolis, Indiana 46204

225 South Main Street, Suite 200

ROYAL OAK LAB

Royal Oak, Michigan 48067

C :\L oc al

P ro je ct s\ 5-

A

_C

EN

TR

AL

_e rin m

.rv t

6/

/2

8:

:5

AM

A2.1A

5-4900

UNIT 'A' FIRST FLOOR PLAN

EM

BJP

D E

LT

O

N K

E

LL

O G

G H

IG

H

S C

H O

O L

D E

LT

O

N K

E

LL

O G

G S

C H

O O

LS

D

E

LT

O N

M

IC

H

IG

A

N

NORTH

1/8" = 1'-0"

UNIT 'A' FIRST FLOOR PLAN

06.10.2019 BIDS &

CONSTRUCTION

A2.1A 1 1/2" = 1'-0"

1 WOOD LOCKER BASE DETAIL

SECTION 10 51 13

METAL LOCKERS

DELTON KELLOGG SCHOOLS

HIGH SCHOOL LOCKER ROOM LOCKER REPLACEMENT

A/E PROJECT 5-4900

SECTION 10 51 13 - METAL LOCKERS

PART 1 - GENERAL

1.1 SUMMARY

A. Scope of Work: Furnish and install steel lockers where shown on the Drawings, complete with all accessories, locks, numbers, etc. ready for use by Owner.

1.2 SUBMITTALS

A. Product Data, Shop Drawings, Samples: Provide Shop Drawings indicating materials of lockers, supports, anchorage, dimensions and manufacturers installation instructions.

1.3 DELIVERY, STORAGE, AND HANDLING

A. Packing and Shipping: Deliver items in manufacturer’s original unopened protective packaging.

B. Storage and Protection:

1. Store materials in original protective packaging to prevent soiling, physical damage or wetting.

2. Handle so as to prevent damage to finished surfaces.

1.4 SEQUENCING AND SCHEDULING

A. Coordinate all work with job site superintendent and all applicable trades.

1.5 WARRANTY

A. Provide minimum two (2) year warranty against defects for materials and installation, unless otherwise indicated.

PART 2 - PRODUCTS

2.1 ACCEPTABLE MANUFACTURERS

A. Republic Storage Systems, Inc., Canton, Ohio; Lyon Metal Products, Incorporated, Aurora, Illinois; Penco Products, Oaks, Pennsylvania; Interior/Medart; Hadrian, Inc.; Art Metal Products;

and DeBourgh.

2.2 PERFORMANCE REQUIREMENTS

A. Accessibility Standard: For lockers indicated to be accessible, comply with applicable provisions in the USDOJ's "2010 ADA Standards for Accessible Design" the ABA standards of the Federal agency having jurisdiction and ICC A117.1. Unless otherwise indicated on drawings, provide a minimum of 5 percent accessible lockers of each type, dispersed throughout the installation.

Coordinate with Architect.

2.3 MATERIALS

A. Mild annealed, cold rolled steel free from surface imperfections. Bolts to be cadmium plated or subjected to other rust-retardant treatment.

B. Lockers in athletic locker rooms areas shall be heavy duty ventilated type, 15”w x 15”d x 72”h, single tier, with flat tops.

C. Lockers in PE locker rooms shall be heavy duty ventilated type, 10”w x 15”d x 72”h, single tier, with flat tops.

The specifications that follow are based on the standard corridor locker and heavy duty vented locker, both by Republic Storage Systems.

DELTON KELLOGG SCHOOLS

2.4 FABRICATION

A. Corridor Lockers:

1. Material: All parts shall be made of mild cold rolled sheet steel. All steel to be free from imperfections and capable of taking a high grade enamel finish.

2. Finish: Before enamel is applied, the surfaces of the steel shall be thoroughly cleaned and phosphatized in a seven stage process. All parts shall then be finished with a heavy coat of enamel. Enamel shall be baked on at 300 degrees for 30 minutes. Color to be selected by the Architect from manufactures standard color selection. Bottoms shall be galvanealed steel or two (2) coats corrosion resistant paint and warranted for 10 years against rust under normal use.

3. Trim and Accessories: Trim and accessories, such as sloping tops, shall be finished to match lockers using the same process outlined above.

4. Tops shall be 18 gauge.

5. Hinges: Shall be at least a 2” high, 5-knuckle, full loop, tight pin style, to be securely welded to frame and riveted to the inside of the door flange.

6. Number Plates: Each locker shall have a polished aluminum number plate with black numerals not less than ½” high. Plates to be attached with rivets.

7. Interior Equipment: Single tier lockers shall have one hat/book shelf. All single, double and triple tier lockers shall have one double prong (single prong in 9” width) back hook and two single prong wall hooks in each compartment. All hooks shall be made of steel, formed with ball points, zinc-plated and attached with two bolts or rivets.

8. Door Frames: Shall be 16 gauge formed into deep, 1” face channel shapes with a continuous vertical door strike integral with the frame on both sides of the door opening.

Cross frame members of 16 gauge channel shapes including intermediate cross frame on double and triple tier lockers shall be securely welded to vertical framing members to ensure rigidity.

9. Doors: Doors shall be 16 gauge steel formed with a full channel shape on the lock side to fully conceal the lock bar, channel formation on the hinge side and right angle formations across the top and bottom. Doors shall have diamond perforations for venting.

10. Locking Device: Shall be positive, automatic, pre-locking type, whereby the locker may be locked while door is open, then closed without unlocking and without damaging locking mechanism.

11. Latching: Shall be a one-piece, pre-lubricated, spring steel latch completely contained within the lock bar, under tension, to provide a rattle-free operation. the lock bar shall be of pre-painted, double-channel steel construction. The lock bar shall be securely contained in the door channel by self-lubricating polyethylene guides that isolate the lock bar from metal-to-metal contact with the door. There shall be three latching points on single tier lockers and two latching points for each door on two, three and four tier lockers. The lock bar travel is limited by contacting resilient high-quality elastomeric cushioning devices located inside the lock bar.

12. Recess Handle: A non-protruding lifting feature shall be provided for actuating the lock bar when opening the door. It shall be contained in a formed 20 gauge stainless steel pocket that is securely assembled to the door. This pocket also provides a recessed area for accommodating the various lock types and the number plate. The lifting trigger within the recess pocket is an integral part of the steel slide plate which is securely attached to the lock bar and functions to transfer the lifting force. The exposed portion of the lifting trigger is encased in a molded ABS thermoplastic cover.

DELTON KELLOGG SCHOOLS

13. Frame Hooks - Silencers: Frame hooks to accept latching shall be of heavy gauge steel, set close in and welded to the door frame. Continuous vertical door strike shall protect frame hooks from door slam damage. A soft rubber silencer shall be provided and securely installed on each frame hook.

14. Body: The body of the locker consists of 24 gauge upright sheets, backs, tops, bottoms and shelves. Tops, bottoms and shelves are flanged on all four sides. Backs are flanged on two sides. Uprights shall be offset at the front and flanged at the rear to provide a double lapped rear corner. All bolts and nuts shall be zinc plated and tamper resistant.

15. 16 gauge Box End Panels with a 1” face are to be installed in any locations with exposed ends of locker banks.

16. Filler Panels: No wider than 2”

PART 3 - EXECUTION

3.1 INSTALLATION

A. Install lockers on existing bases and in the locations of the existing lockers.

B. Anchoring: Anchored floor and wall.

C. Installation per manufacturer’s recommendations.

END OF SECTION