HERIBERTO HERNANDEZ Schedule of Services .xls
XLS spreadsheet 27 KB Posted
- Attached to
- Dock-Side (DS): USCGC HERIBERTO HERNANDEZ Repair
- Solicitation number
- 70Z080-21-Q-P4501800
About this file
This document contains a pricing schedule for dock-side repair services for the USCGC HERIBERTO HERNANDEZ. The schedule lists various repair and maintenance items with blank unit prices and quantities to be filled in by a contractor, including a 6000 hour overhaul of the main diesel engine, cleaning and inspecting heat exchangers and water tanks, assessing watertight closures, performing thermographic inspections of electrical systems up to 450 volts, cleaning machinery ventilation and HVAC ducts, and performing various maintenance under AFC 45. Travel and per diem costs are also included. The total proposed price will be calculated from the unit prices provided. A composite labor rate for additional work is also requested.
The related federal contract opportunity is a solicitation for dock-side repair of the USCGC HERIBERTO HERNANDEZ issued by the Department of Homeland Security Coast Guard. Vendors are invited to submit pricing to provide the repair and maintenance services listed in the schedule.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOS&S
| PRICING SCHEDULE FOR: Contractor's Name Here | |||||||
| USCGC HERIBERTO HERNANDEZ (WPC-1114) DOCKSIDE AVAILABILITY FY2021 | |||||||
| Solicitiation: | Attachment 1 | ||||||
| ITEM | DESCRIPTION | UNIT PRICE | UNIT | QTY | EXTENDED PRICE | Type | AFC |
| D-001 | Propulsion, Diesel Engine, Main, 6000 Hour Overhaul | $ - 0 | JOB | 1 | $ - 0 | RWI | 45 |
| D-002 | Heat Exchangers; Clean, Inspect And Hydro | $ - 0 | JOB | 1 | $ - 0 | RWI | 45 |
| O-003 | Topside Exterior Surfaces, Preserve (Partial, Opt) | $ - 0 | JOB | 1 | $ - 0 | CSMP | 30 |
| D-004 | U/W Body (waterborne), Clean and Inspect | $ - 0 | JOB | 1 | $ - 0 | CSMP | 30 |
| D-005 | Watertight Closures, Assess | $ - 0 | JOB | 1 | $ - 0 | CSMP | 45 |
| D-006 | Electrical Power Distribution System, Thermographic Inspection (450 VAC And Below) | $ - 0 | JOB | 1 | $ - 0 | CSMP | 45 |
| D-007 | Machinery Ventilation System, Clean | $ - 0 | JOB | 1 | $ - 0 | CSMP | 45 |
| D-008 | HVAC Duct System, Clean | $ - 0 | JOB | 1 | $ - 0 | CSMP | 30 |
| D-009 | Sewage and Grey Water System, Clean and Inspect | $ - 0 | JOB | 1 | $ - 0 | CSMP | 45 |
| O-010 | Grey Water Tank, Preserve (Opt) | $ - 0 | JOB | 1 | $ - 0 | CSMP | 30 |
| D-011 | Various Maintenance (AFC45 DD1), Perform | $ - 0 | JOB | 1 | $ - 0 | CSMP | 45 |
| D-00C | Travel and Perdiem | $ - 0 | JOB | 1 | $ - 0 | 45 | |
| Total Price of Definite Items | $ - 0 | ||||||
| Total Price of Option Items | $ - 0 | ||||||
| Total Price of Travel and Per Diem | $ - 0 | ||||||
| Total Contract Price | $ - 0 | ||||||
| Composite Labor Rate for Growth Work | $ - 0 | Hourly Rate |
&C(11/23/2020) Draft-00 - Page &P of &N