AMEND 01 Questions and Answers.pdf
PDF 417 KB Posted
- Attached to
- Video Surveillance System & Video Intercom Buzzer Federal contract opportunity
- Solicitation number
- HC101920R0012
- Issued by
- Defense Information Systems Agency
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| AMEND 01Pharmacy Drawings.png | PNG image | |
| AMEND 01 Pharmacy_Server_Storage.png | PNG image | |
| AMEND 01 PWS CCTV R1 10 Aug 2020.docx | DOCX document | |
| AMEND 01 Pharm Storage.png | PNG image | |
| QASP.pdf | ||
| HC101920R0012.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
QUESTIONS & ANSWERS
1. Are there floor plans/ drawings for these buildings? Yes, see attached floor plans with camera markups and approximate distance.
2. Are there drawings that have markings showing where cameras and Video Intercom Buzzer has to be installed? Yes, please see attached plans.
3. SOW Note 4.3, page 54, calls for video intercom: does door where video intercom needs to be installed have electric strike or electric door lock or electric mag lock or electric push bar? Yes, door has a paddle handle with an electric strike and access control system installed.
4. Does all cabling need to be in conduit all the way? If there is a track way in the ceiling, No. If it's on the exterior of the building, Yes. Insuring to firestop any firewall penetration.
5. Is there existing conduit that can be used? And if so, how much? No, there is no conduit in building 1407 or 1535.
6. Is ceiling a drop ceiling type? Yes, both facilities have drop ceilings.
7. How far is pharmacy area from Communication Room? Approximately 60 feet.
8. How far is door where video intercom needs to be installed from Communication Room? Video needs to be installed on front door with a monitoring station at the front desk with capability to view who is at the door. However, the distance from door to comms closet is approximately 52 feet.
9. How far is SARP front desk where video intercom station needs to be installed from
Communication Room? Approximately 35 feet.
10. On Page 60 and 61 there are 2 adresses listed:
Branch Health Clinic Makalapa Pharmacy, B1407, Makalapa Drive, JBPHH HI
Branch Health Clinic Makalapa SARP, B1535, Makalapa Drive, JBPHH HI On Page 54 section 6. It only states that we are installing cameras at BLdg 1407.
If installation is required at both buildings B1407 and B1535 is the fiber or copper connectivity between these buildings? The two addresses are for both facilities. Cameras will only be getting installed at building 1407. Building 1535 will only have the Aiphone video buzzer and monitor installed.
11. SOW note 6.2 Monitoring stations, page 55, calls for 2 workstations. One to be with 1 x 43” screen and one to be with 1 x 24” screen. In Note 6.2.f it says to provide 2 x 24” screens. What is second screen for? For same workstation? There will not be a need for a second monitor on the workstation.
12. SOW note 6.2 Monitoring stations, page 55, calls for 2 workstations: one with 43” screen for viewing and one with 24” screen for 90 days video storage. 2nd workstation with 24” screen for
90 days video storage: is it NVR? Second 24" workstation will not be needed. Only one (1) 43" station for viewing multiple cameras and one (1) 24" workstation that will have recording capabilities.
13. Do we provide 1 NVR and 1 Workstation or 1 NVR and 2 Workstations? Contractor will provide one (1) 43" viewing station and one (1) workstation.
File details come from the government source that posted it. Updated .