HC101325QA193-0001.v2.pdf
PDF 23 KB Posted
- Solicitation number
- HC101325QA193
- Issued by
-
Defense Information Systems Agency
About this file
This document is an Amendment (0001) to a federal solicitation for telecommunications services. The solicitation seeks a quote to provide, install, and maintain a channelized OC-12 (622.08MB) circuit between Seymour Johnson Air Force Base and Fort Liberty, North Carolina, for a 60-month period with no basic termination liability. Key details include a service date of September 11, 2025, and a quote due date of April 21, 2025. The telecommunications circuit requires specific technical parameters, including a line rate of 622.08MB/s, SONET/STS-12 frame format, and performance thresholds such as 99.5% availability and specific error second tolerances. Vendors must provide detailed information about circuit installation, including sub-contractor details, fiber miles, and round-trip delay measurements. The solicitation is issued by the Defense Information Systems Agency (DISA) using a lowest price technically acceptable (LPTA) source selection process, with the NAICS code 517111 and no small business set-aside.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101325QA193-0002.v0.pdf | ||
| HC101325QA193.v3.pdf | ||
| Vendor Sample Maps Version2.pdf | ||
| Vendor Block Sample_Version3.pptx | PPTX presentation |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 4/15/2025
SUBJECT: HC101325QA193-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: AMEND 0001 ISSUED TO UPDATE LOCATION INFORMATION, REQUESTED
SERVICE DATE, AND QUOTE DUE DATE ALL ELSE REMAINS THE SAME
1. SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A CHANNELIZED OC-12
(622.08MB) BETWEEN (BLDG) 2401, (ROOM) COMM, CAMP FEDERAL LANE, SEYMOUR
JOHNSON AFB, NC(SYMJHAFB/CCI) AND (BLDG) 1-1434, (ROOM) 6, 3338 SCOTT STREET,
FT LIBERTY, NC (FTLIBRTY/CCI) FOR 60 MONTHS WITH NO BASIC TERMINATION LIABILITY
(BTL).
2. CONTRACTORS MUST ADDRESS TESTING & ACCEPTANCE COMPLIANCE IN PROPOSAL/
QUOTE WITH UNDERSTAND/WILL COMPLY.
3. CONTRACTORS ARE RESPONSIBLE FOR READING AND ADDRESSING ALL TECHNICAL
REQUIREMENTS OF THIS SOLICITATION. CONTRACTORS MUST ALSO READ AND COMPLY
DITCO ADDITIONAL TELECOMMUNICATIONS TEXT (DATT) AND FEDERAL ACQUISITION
REGULATION (FAR) CLAUSES AND ADDRESS SPECIFIC INSTRUCTIONS IN DATT 4, 7, 52 AND
53 AND OTHER THAT REQUIRE ADDITIONAL INFORMATION TO BE IN COMPLIANCE.
4. THE SERVICE DATE TO BE MET IS: 11 SEP 25
5. CONTRACTORS MUST CONSIDER ALL ISSUES THAT MAY DELAY THE DELIVERY OF
CIRCUIT ON APPROVED SERVICE DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR
REQUEST CONSIDERATION IAW DATT 42 FOR FAILURE TO MEETCONTRACTUAL SERVICE
DATE.
6. QUOTES MUST INCLUDE AS MUCH INFORMATION ABOUT HOW CIRCUIT WILL BE
INSTALLED. I.E. NAME AND INFORMATION ABOUT SUB-ONTRACTOR/LONG HAUL
PROVIDER/OTHER CARRIER INSTALLING CIRCUIT IS ON NET/OFF NET, RTD, JUMBO
FRAMING, TESTING AND OTHER APPLICABLE TECHNICAL INFORMATION. FURTHERMORE,
IF A BUILD IS REQUIRED TO INSTALL, VENDOR MUST INDICATE THE SCOPE OF THE BUILD
(LENGTH, BURIED/AERIAL, TRENCHING/DIRECTIONAL BORING, NEW CONDUIT).
7. ESTABLISH TSP: TSP0F671J-01
8. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101325QA192/SG05FEB259211.
9. TESTING & ACCEPTANCE - PARAMETERS:
HC101325QA193-0001
1) VENDOR MUST DELIVER OC-12 SERVICE 2W (UNPROTECTED) FROM LOCATION STATED
IN PARAGRAPH 3. 2) REQUEST VENDOR PROVIDE LIGHT LEVEL READINGS (DB LOSS) ON
EXTENSION FROM THE COMMERCIAL POP TO THE GOVERNMENT SERVICE DELIVERY
POINT (SDP) AT BOTH LOCATIONS. LIGHT LEVELS MUST BE ADJUSTED TO -10 TO -18. 3)
VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO INSTALLATION AT
ALL TERMINATING GOVERNMENT LOCATIONS. VENDOR MUST COORDINATE SITE VISIT
WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT
BOTH USER LOCATIONS. 4) VENDOR MUST CONTACT IMPLEMENTATION ASSISTANCE
TO ESTABLISH THE COORDINATION AND ACTIVATION PROCESS FOR TURN-UP OR
ANY SITE CONTACT ISSUES. 5) INSTALLATION AND MAINTENANCE: IAW THE UNIQUE
INSTALLATION FACTORS IN PARAGRAPH 3. 6) VENDOR REQUIRED TO HAVE CIRCUIT
VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES. 7) VENDOR MUST HAVE A 24X7 NETWORK
OPERATIONS CENTER. 8) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO
REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED. 9) TECHNICAL SPECIFICATIONS
FIBER TERMINATION: OPTICAL, SINGLE MODE, 1310NM PHYSICAL TERMINATION: SC/SC
CONNECTORS FRAME FORMAT: STS-12 RATE: PLUS OR MINUS 20 PPM CHANNELIZATION
REQUIRED: NO CONCATENATION REQUIRED: NO GFE CLOCKING: VENDOR ESFU (OR
EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT. 10) NO NETWORK INTERFACE
UNIT 11) DEDICATED PATH 12) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE
TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER. 13)
TESTING PARAMETERS AND THRESHOLDS: ERROR PERFORMANCE (AVAILABILITY, SES,
DM, EFS) AND LOSS OF BIT COUNT INTEGRITY SHALL BE MEASURED AND RECORDED
OVER THE DURATION OF THE CONTIGUOUS 72 HOUR TESTING INTERVAL AND SHALL
BE MEASURED AND RECORDED PER DEFINITION IN ITU RECOMMENDATION G.826 AND
M.2100. ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER
THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN 99.5% OR
BETTER SEVERELY ERRORED SECONDS (SES) SHALL BE LESS THAN 0.02% DEGRADED
MINUTES (DM) SHALL BE LESS THAN 0.2% ERROR FREE SECONDS (EFS) SHALL BE
GREATER THAN 99% 15) LOSS OF BIT COUNT INTEGRITY (LBCI): LOSS OF BIT COUNT
INTEGRITY SHALL BE MONITORED ONLY BY THE FOLLOWING METHOD: USING TEST
EQUIPMENT WHICH CAN DETECT AND MEASURE THE OCCURRENCE OF THE INSERTION
OR DELETION OF ONE OR MORE BITS INTO THE DIGITAL BIT STREAM, ON MANY
MANUFACTURERS BERT TEST EQUIPMENT THIS IS MONITORED USING THE "PATTERN
SLIP" PARAMETER WHERE EVERY OCCURRENCE OF A PATTERN SLIP "EVENT" MARKS
THE OCCURRENCE OF A LBCI (RATHER THAN THE RAW TOTAL NUMBER OF PATTERN
SLIPS ACCUMULATED OVER A TESTING INTERVAL) MEAN TIME TO LOSS OF BIT COUNT
INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24 HOURS. ROUND TRIP DELAY (RTD):
UP TO 500 AIR-MILES THE RTD SHALL BE LESS THAN OR EQUAL TO (10) MILLISECONDS.
ABOVE 500 AIR-MILES THE RTD SHALL BE LESS THAN OR EQUAL TO 1 MILLISECOND
DELAY PER (120 ROUND TRIP)/(60 ONE WAY) AIR-MILES. THE VENDOR'S FDP INSTALLED
IN THEIR COMMERCIAL SUITE. VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS
ORDER THE EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE. VENDOR MUST
CONDUCT A SATISFACTORY 72 HOUR END TO END TEST IAW ITU STANDARD M.2101 PRIOR
TO TURN OVER TO THE GOVERNMENT FOR ACCEPTANCE TESTING. THE END TO END TEST
WILL NOT BE COMPLETED WITH LOOPS. THE VENDOR TEST SET/SETS MUST HAVE THE
ABILITY TO PRINT OR ELECTRONICALLY OUTPUT THE TEST RESULTS AND THOSE RESULTS
MUST BE E-MAILED TO THE ACCEPTING AUTHORITY FOR REVIEW. ALL EQUIPMENT AND
CIRCUIT PROBLEMS WILL BE REPORTED TO THE CONUS IP BACKBONE E&I GROUP: (C)
618-418-9950 TOLL FREE: 855-868-9950 VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT
NO. AND LEC CKT ID PRIOR TO TURN UP TO THE GOVERNMENT. S. COMPLETION REPORT:
(1) STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO WILL SUBMIT COMPLETION
REPORT IAW DISAC 310-130-1, SUPP 1, 2, 3 FORMAT OR DISAC 310-70-1. REPORT WILL
BE ADDRESSED TO ORIGINATOR AND ALL ADDRESSEES OF THIS (TSO). (2) STATIONS
IN PARA 3 OF THIS (TSO) ARE RESPONSIBLE FOR VERIFYING IN-STATION DETAILS AND
FORWARDING THE CORRECT INFORMATION, IF ANY DISCREPANCIES ARE NOTED, TO THE
CCO/CMO DESIGNATED IN PARA 2H. THE CCO/CMO WILL SUBMIT CORRECTIONS TO DISA
VIA "EXCEPTION REPORT" IAW DISAC 310-130-1, CHAP 2. T.
7) ***ATTENTION SEYMOUR JOHNSON LOCATION*** DIVERSITY IS NOT REQUIRED. 8)
THE TELECOM PROVIDER MUST PROVIDE DITCO COLOR POWERPOINT DRAW INGS FOR
TECHNICAL REVIEW SHOWING THE ROUTE FROM THE COMMERCIAL D EMARCS TO THE
SUPPORTING CENTRAL OFFICES AND/OR WIRING CENTERS. D RAWINGS MUST INCLUDE
TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD) . ADDITIONALLY, THE VENDOR IS TO
PROVIDE DITCO WITH DETAILED CIRC UIT/PATH CONNECTIVITY DIAGRAMS, IN KMZ OR KML
FORMAT, IDENTIFYING ALL POINTS OF PRESENCE (POP) FOR PROPOSAL EVALUATION AND
AS A FI NAL RECORD OF THE INSTALLED PATH. THESE DIAGRAMS MUST BE PROVIDE D TO
DISA HQ IE16 (DISA.MEADE.IE.MBX.IE16-PROVISIONING-TEAM@MAIL. MIL) FOR HISTORICAL
PURPOSES. 8. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES.
1) VENDOR MUST MEET SVC DATE. 2) CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: FRAME FORMAT: STS-12, 1310NM RATE: PLUS OR MINUS 20 PPM
(B) GOVERNMENT PROPOSED CHANNELIZATION: 9 STS-1S (TIMESLOTS 1-9) 1 STS-3CS
(TIMESLOTS 10-12) (C) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO
USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OF THE TIME OR IAW
THE APPROVED TARIFFS. (D) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR
TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED. (E) GFE CLOCKING: VENDOR
ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT. (F) SINGLE MODE FIBER
TERMINATIONS "SC" CONNECTORS. (G) NO NETWORK INTERFACE UNIT. (H) DEDICATED
PATH. (I) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT
OUTAGES. (J) VENDOR MUST CONDUCT A SATISFACTORY 72 HOUR END TO END TEST
UTILIZING A 2E23 TEST PATTERN IAW ANSI STANDARD T1.514. ADDITIONALLY, VENDOR
MUST CONDUCT SATISFACTORY CONTINUITY CHECKS AND INITIAL 15 MINUTE END TO
END TEST ON EACH STS-1. AFTER COMPLETION OF CONTINUITY CHECKS AND INITIAL
TESTING, VENDOR MUST COMPLETE A SATISFACTORY 72 HOUR END TO END TEST ON THE
FIRST STS-1 (TIME-SLOT NUMBER 1) END TO END PRIOR TO TURNING OVER THE OC-12 TO
THE ACCEPTING AUTHORITY. THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO
PRINT THE TEST RESULTS AND THOSE RESULTS MUST BE E-MAILED TO THE ACCEPTING
AUTHORITY FOR REVIEW. (K) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL
CENTER. (L) OC-12 SERVICE WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY
THE DGOC: PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE BB
TEAM PHONE: (C) 618-418-9813, (D) 418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-
INFRASTRUCTURE-INTEGRATION-L EASE-BB-T@MAIL.MIL ALT POC: ORGANIZATIONAL
NUMBER (CASA RF CIRCUI T ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:
DISA. SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL (M) THE VENDOR MUST
PROVIDE THE LONG HAUL CIRCUIT NUMBER AND THE 1-800 TROUBLE REPORT NUMBER
TO THE ACCEPTING AUTHORITY PRIOR TO THE GOVERNMENT ACCEPTING SERVICE.
INSIDE WIRING MUST BE COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR
TO TURN-UP TO THE GOVERNMENT. 3) VENDOR IS RESPONSIBLE FOR INSTALLATION
AND MAINTENANCE OF OC-12 SERVICE IAW UNIQUE INSTALLATION FACTORS. 4) INSIDE
WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS. 5) VENDOR
MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING
ACCESS TO FACILITIES AT BOTH USER LOCATIONS. 6) FOR UNSATISFACTORY SERVICE
OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED
TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT
CENTER (DCCC) SCOTT AFB, IL. TOLL FREE: 1-855-868-9500, COML: 618-418-9500,
DSN: 312-418-9500. 7) DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW THE
"PROCUREMENT GUIDE FOR TELECOMMUNICATIONS" BY THE STATION DESIGNATED AS
CCO/CMO. GUIDANCE ON SUBMISSION IS AVAILABLE AT HTTPS://WWW.DITCO.DISA.MIL/
DOCS/PROCUREMENTGUIDEFORTELECOMM UNICATIONS.PDF
MINIMUM TECHNICAL SPECIFICATIONS: SPECIFIC FORMAT TO BE USED IS: LINE RATE:
622.08MB/S 20 PPM. LINE CODE: OPTIC FRAME FORMAT: SONET/STS-12 1) TEST AND
ACCEPTANCE: FIBER OPTIC OC-12 CIRCUITS SHALL PASS A FULLY DOCUMENTED
SATISFACTORY 72 HOUR SOAK TEST BY THE GOC AT SCOTT AFB, IL. PRIMARY: (C)
618-418-8691 (D) 418-8691. 2) TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING
TESTING PARAMETERS SHALL BE MEASURED DURING TEST AND ACCEPTANCE TESTING.
ERROR PERFORMANCE (AVAILABILITY, SES, DM, EFS) AND LOSS OF BIT COUNT INTEGRITY
SHALL BE MEASURED AND RECORDED OVER THE DURATION OF THE CONTIGUOUS 72
HOUR TESTING INTERVAL AND SHALL BE MEASURED AND RECORDED PER DEFINITION
IN ITU RECOMMENDATION G.826 AND M.2100. 3) ERROR PERFORMANCE: ERROR
PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER THRESHOLDS TO
BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN 99.5%. SEVERELY ERRORED
SECONDS (SES) SHALL BE LESS THAN 0.02%. DEGRADED MINUTES (DM) SHALL BE LESS
THAN 0.2%. ERROR FREE SECONDS (EFS) SHALL BE GREATER THAN 99%. 4) LOSS OF
BIT COUNT INTEGRITY (LBCI): LOSS OF BIT COUNT INTEGRITY SHALL BE MONITORED
ONLY BY THE FOLLOWING METHOD: USING TEST EQUIPMENT WHICH CAN DETECT AND
MEASURE THE OCCURRENCE OF THE INSERTION OR DELETION OF ONE OR MORE BITS
INTO THE DIGITAL BIT STREAM, ON MANY MANUFACTURERS BERT TEST EQUIPMENT THIS
IS MONITORED USING THE "PATTERN SLIP" PARAMETER WHERE EVERY OCCURRENCE
OF A PATTERN SLIP "EVENT" MARKS THE OCCURRENCE OF A LBCI (RATHER THAN THE
RAW TOTAL NUMBER OF PATTERN SLIPS ACCUMULATED OVER A TESTING INTERVAL).
X. 5) MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER
THAN 24 HOURS. 6) ROUND TRIP DELAY (RTD) FOR THIS OC-12 WILL BE MEASURED IN
MILLISECONDS FROM THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-A TO THE
CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR
EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION.
THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE RTD DURING THE TURN-UP
AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE CONTRACTORS PROPOSAL, DISA
IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.
10. THE TELECOM PROVIDER MUST PROVIDE DITCO COLOR POWERPOINT DRAW INGS FOR
TECHNICAL REVIEW SHOWING THE ROUTE FROM THE COMMERCIAL D EMARCS TO THE
SUPPORTING CENTRAL OFFICES AND/OR WIRING CENTERS. D RAWINGS MUST INCLUDE
TOTAL FIBER MILES AND ROUND-TRIP DELAY (RTD) . ADDITIONALLY, THE VENDOR IS TO
PROVIDE DITCO WITH DETAILED CIRC UIT/PATH CONNECTIVITY DIAGRAMS, IN KMZ OR KML
FORMAT, IDENTIFYING ALL POINTS OF PRESENCE (POP) FOR PROPOSAL EVALUATION AND
AS A FI NAL RECORD OF THE INSTALLED PATH. THESE DIAGRAMS MUST BE PROVIDED TO
DISA HQ IE16 (DISA.MEADE.IE.MBX.IE16-PROVISIONING-TEAM@MAIL. MIL) FOR EVALUATION
AND APPROVAL.
11. CONTRACTORS MUST COORDINATE THE IMPLEMENTATION, END-TO-END
TESTING, AND 72-HOUR TEST RESULTS WITH THE DISA IMPLEMENTATION TEAM AT
DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTUREINTEGRATION-LEASE-BB-T@MAIL.MIL.
CONTRACTORS WILL BE GIVEN STEP BY STEP INSTRUCTIONS THAT MUST BE FOLLOWED
TO GET CIRCUIT GOVERNMENT ACCEPTANCE BEFORE SUBMITTING NOC. USE FOR DISA
WAVE REQUIREMENTS (SG) ONLY
12. QUOTES MUST BE UPLOADED TO IDEAS. GOVERNMENT IS NOT RESPONSIBLE FOR
MISSING OR OVERLOOKED QUOTES.
13. THIS IS A REAWARD OF A CURRENT SERVICE, (PTON000048EBM). IF THE INCUMBENT
QUOTE IS EVALUATED AS THE LOWEST PRICE TECHNICABLE ACCEPTABLE, THE CURRENT
CSA WILL BE ADMINSTRATIVELY DISCONTINUED USING THE DATE PRIOR TO THE START
DATE OF NEW CSA. REMOVE IF PROCESSING A NEW LEASE/START
FAILURE TO READ AND ADDRESS ANY OF THE TECHNICAL REQUIREMENTS AND SERVICE
DATE REQUESTED IN THIS INQUIRY SHALL RENDER THE QUOTE NON-COMPLIANT AND
RESULT IN IT BEING EXCLUDED FROM EVALUATION AND AWARD.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: SG05FEB259210
4. CCSD: DIYU68C3
Z. DITCO CONTACT:
Jennifer Voss
667-890-7560 jennifer.n.voss.civ@mail.mil
Kristina M. Hoff
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph E.SERVICE DATE change from:
Aug 3, 2025
To:
Sep 11, 2025
Paragraph M.3.TSR NUMBER change from:
SG05FEB259210A
SG05FEB259210
Paragraph V.QUOTE DUE DATE AND TIME change from:
Apr 5, 2025 12:30:00 PM CDT
Apr 21, 2025 12:30:00 PM CDT
Location A, LOCATION OF TERMINATION A change from:
ADDRESS: 1-1434, 3338 SCOTT STREET, FT LIBERTY,NC 28310-5000
ROOM: 6
LOCATION: FTLIBRTY
ADDRESS: 2401, CAMP FEDERAL LANE, SEYMOUR JOHNSONAFB, NC 27531-5000
ROOM: COMM; 1 FL
LOCATION: SYMJHAFB
Location A, DEMARK change from:
BLDG 1-1434, ROOM 6, 3338 SCOTT STREET, FT BRAGG, NC
28307-5000
(PMRY POC) MR. KENNETH A COX;
(UNCLASS USER) KENNETH.A.COX.CIV@MAIL.MIL;
(CMCL) 910-396-4377
To:
BLDG 2401, COMM; 1 FL, 2401 CAMP FEDERAL LANE; SEYMOUR
JOHNSON AFB, NC 27531
(UNCLASS USER) GREGORY.COYLE@US.AF.MIL; (CMCL) 919-722-88
Location A, UNIQUE INSTALLATION FACTORS change from:
(1) FIBER CABLE X-CONNECT, ON-BASE, INSIDE WIRE, SINGLE-MODE, 1310NM, 4CS SCOI PERSONNEL. (2) FIBER
TERMINATING PATCH PANEL (SITE PROVIDED) (3) FIBER CABLE X-CONNECT, ON-BASE, INSIDE WIRE, SINGLE-
MODE, 1310NM, 4CS SCOI PERSONNEL. AMPLIFYING INFO: A. 4CS SCOI PERSONNEL ARE RESPONSIBLE FOR
INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE SIDE OF THE SITE PROVIDED FIBER
TERMINATING PATCH PANEL BLDG 2904, TELCO FRAME ROOM, TO THE LINE SIDE OF THE SITE PROVIDED FIBER
TERMINATING PATCH PANEL BLDG 3200, TELEPHONE SWITCH ROOM (ROOM 133), USING EXISTING ON-BASE
SINGLE-MODE FIBER. B. 4CS SCOI PERSONNEL ARE RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF
SINGLE MODE FIBER FROM THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG 3200, TELEPHONE SWITCH ROOM (ROOM 133), TO THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH
PANEL BLDG 2401, COMM ROOM, USING EXISTING ON-BASE SINGLE-MODE FIBER.
To:
FIBER CABLE X-CONNECT, ON-BASE, INSIDE WIRE, SINGLE-MODE, 1310NM, 4CS SCOI PERSONNEL. (2) FIBER
TERMINATING PATCH PANEL (SITE PROVIDED) (3) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-
MODE, 1310NM, TELCO (4) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL CARRIER SYSTEM)
AMPLIFYING INFO: A. 4CS SCOI PERSONNEL ARE RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE
MODE FIBER FROM THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG 3200, TELEPHONE SWITCH ROOM (ROOM 133), TO THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH
PANEL BLDG 2401, COMM ROOM, USING EXISTING ON-BASE SINGLE-MODE FIBER. B. VENDOR IS RESPONSIBLE FOR
INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE SIDE OF THE SITE PROVIDED FIBER
TERMINATING PATCH PANEL BLDG 2401, COMM ROOM TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF
PRESENCE [FIBER DISTRIBUTION PANEL (FDP)] BLDG 2401, COMM ROOM. COORDINATE WITH SITE FOR TYPE
CONNECTORS TO SITE PATCH PANEL. C. THE CIRCUIT MUST BE TAGGED WITH THE VENDOR'S CIRCUIT ID AS
APPLICABLE AT THE DROP SIDE OF THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 2401, COMM
ROOM. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION
POINT WHEN INSTALLATION IS COMPLETE. D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON
THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE SURVEYS OR INSTALLATIONS.
Location A, CONTACT change from:
PRI: KENNETH COX, D236-4377, C910-396-4377
EMAIL: KENNETH.A.COX.CIV@ARMY.MIL
ALT: DANNY CLARK, D236-4377, C910-396-4377
EMAIL: DANNY.R.CLARK10.CIV@ARMY.MIL
ALT: BJ OXENDINE, D498-1828, C910-908-1828
EMAIL: BJ.OXENDINE.CIV@ARMY.MIL
ORG EMAIL: USARMY.BRAGG.NETCOM.MBX.BRAGG-NEC-VB-SP
ECIAL-CIRCUIT@ARMY.MIL
To:
(PMRY POC) SERGEANT (AIR FORCE, MARINE) ELY S LINARES;
(UNCLASS ORG) ELY.LINARES@US.AF.MIL; (CMCL) 1-919-
722-2666
(ALT POC) SENIOR AIRMAN AIR FORCE THOMAS CRUZ; (UNCLASS USER)
THOMAS.CRUZ.4@US.AF.MIL; (CMCL) 919-722-2666; (DSN) 722-2666
Location A, INTERFACE change from:
SONET OC-12; OPTICAL; SNAP CLICK (SC)
Location A, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:
CPIWI-NO/CPIWM-NO
CPIWI-YES/CPIWM-YES
Location A, NPA/NXX change from:
910/396
919/722
Location A, TERMINAL EQUIPMENT change from:
EQUIPMENT INFORMATION: COMMERCIAL FIBER POINT OF PRESENCE
To:
EQUIPMENT INFORMATION: FIBER TERMINATING PATCH PANEL (SITE
PROVIDED) COMMERCIAL FIBER POINT OF PRESENCE
Location B, LOCATION OF TERMINATION B change from:
ADDRESS: 2401, CAMP FEDERAL LANE, SEYMOUR JOHNSONAFB, NC 27531-5000
ROOM: COMM; 1 FL
LOCATION: SYMJHAFB
ADDRESS: 1-1434, 3338 SCOTT STREET, FT LIBERTY,NC 28310-5000
ROOM: 6
LOCATION: FTLIBRTY
Location B, DEMARK change from:
BLDG 2401, COMM; 1 FL, 2401 CAMP FEDERAL LANE; SEYMOUR
JOHNSON AFB, NC 27531
(UNCLASS USER) GREGORY.COYLE@US.AF.MIL; (CMCL) 919-722-88
To:
BLDG 1-1434, ROOM 6, 3338 SCOTT STREET, FT BRAGG, NC
28307-5000
(PMRY POC) MR. KENNETH A COX;
(UNCLASS USER) KENNETH.A.COX.CIV@MAIL.MIL;
(CMCL) 910-396-4377
Location B, UNIQUE INSTALLATION FACTORS change from:
FIBER CABLE X-CONNECT, ON-BASE, INSIDE WIRE, SINGLE-MODE, 1310NM, 4CS SCOI PERSONNEL. (2) FIBER
TERMINATING PATCH PANEL (SITE PROVIDED) (3) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-
MODE, 1310NM, TELCO (4) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL CARRIER SYSTEM)
AMPLIFYING INFO: A. 4CS SCOI PERSONNEL ARE RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE
MODE FIBER FROM THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG 3200, TELEPHONE SWITCH ROOM (ROOM 133), TO THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH
PANEL BLDG 2401, COMM ROOM, USING EXISTING ON-BASE SINGLE-MODE FIBER. B. VENDOR IS RESPONSIBLE FOR
INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE SIDE OF THE SITE PROVIDED FIBER
TERMINATING PATCH PANEL BLDG 2401, COMM ROOM TO THE DROP SIDE OF THE COMMERCIAL FIBER POINT OF
PRESENCE [FIBER DISTRIBUTION PANEL (FDP)] BLDG 2401, COMM ROOM. COORDINATE WITH SITE FOR TYPE
CONNECTORS TO SITE PATCH PANEL. C. THE CIRCUIT MUST BE TAGGED WITH THE VENDOR'S CIRCUIT ID AS
APPLICABLE AT THE DROP SIDE OF THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 2401, COMM
ROOM. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION
POINT WHEN INSTALLATION IS COMPLETE. D. VENDOR MUST SCHEDULE/COORDINATE WITH THE POC'S LISTED ON
THIS ORDER 72 HOURS IN ADVANCE PRIOR TO SITE SURVEYS OR INSTALLATIONS.
(1) FIBER CABLE X-CONNECT, ON-BASE, INSIDE WIRE, SINGLE-MODE, 1310NM, 4CS SCOI PERSONNEL. (2) FIBER
TERMINATING PATCH PANEL (SITE PROVIDED) (3) FIBER CABLE X-CONNECT, ON-BASE, INSIDE WIRE, SINGLE-
MODE, 1310NM, 4CS SCOI PERSONNEL. AMPLIFYING INFO: A. 4CS SCOI PERSONNEL ARE RESPONSIBLE FOR
INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE SIDE OF THE SITE PROVIDED FIBER
TERMINATING PATCH PANEL BLDG 2904, TELCO FRAME ROOM, TO THE LINE SIDE OF THE SITE PROVIDED FIBER
TERMINATING PATCH PANEL BLDG 3200, TELEPHONE SWITCH ROOM (ROOM 133), USING EXISTING ON-BASE
SINGLE-MODE FIBER. B. 4CS SCOI PERSONNEL ARE RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF
SINGLE MODE FIBER FROM THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG 3200, TELEPHONE SWITCH ROOM (ROOM 133), TO THE LINE SIDE OF THE SITE PROVIDED FIBER TERMINATING PATCH
PANEL BLDG 2401, COMM ROOM, USING EXISTING ON-BASE SINGLE-MODE FIBER.
Location B, CONTACT change from:
PRI: NICHOLAS GERSPER, D722-4990, C919-722-4990
EMAIL: NICHOLAS.GERSPER@US.AF.MIL
ALT: ALEXANDRIA.COBEDESH, D722-4990, C919-722-4990
EMAIL: ALEXANDRIA.COBEDESH@US.AF.MIL
ORG EMAIL: CIRCUIT.ACTIONS7@US.AF.MIL
To:
PRI: KENNETH COX, D236-4377, C910-396-4377
EMAIL: KENNETH.A.COX.CIV@ARMY.MIL
ALT: DANNY CLARK, D236-4377, C910-396-4377
EMAIL: DANNY.R.CLARK10.CIV@ARMY.MIL
ALT: BJ OXENDINE, D498-1828, C910-908-1828
EMAIL: BJ.OXENDINE.CIV@ARMY.MIL
ORG EMAIL: USARMY.BRAGG.NETCOM.MBX.BRAGG-NEC-VB-SP
ECIAL-CIRCUIT@ARMY.MIL
Location B, INTERFACE change from:
SONET OC-12; OPTICAL; SNAP CLICK (SC)
Location B, INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED change from:
CPIWI-YES/CPIWM-YES
CPIWI-NO/CPIWM-NO
Location B, NPA/NXX change from:
919/722
910/396
Location B, TERMINAL EQUIPMENT change from:
EQUIPMENT INFORMATION: FIBER TERMINATING PATCH PANEL (SITE
PROVIDED) COMMERCIAL FIBER POINT OF PRESENCE
EQUIPMENT INFORMATION: COMMERCIAL FIBER POINT OF PRESENCE
File details come from the government source that posted it. Updated .