This is a solicitation amendment requesting quotes to provide, install, and maintain a 10Gbps non-switched Ethernet circuit between Building 2664 at China Lake Naval Weapons Center in Ridgecrest, California and Building 2145 at Beale Air Force Base in California. Quotes are due by June 13, 2022 and must include monthly and non-recurring charges. The circuit must meet a maximum round trip delay of 10 milliseconds and be engineered and provisioned with full diversity from a separate circuit procured under Solicitation HC101322QA349. The selected vendors must provide documentation demonstrating the diversity requirement is met, including drawings depicting routes, distances, and delays. Installation for the termination points is required by September 26, 2022, with testing and acceptance to be coordinated with the customer. The Defense Information Systems Agency is the procuring agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sample Vendor Block Diagram and Maps.pdf | ||
| HC101322QA348 Circuit Specs and Testing.docx | DOCX document | |
| HC101322QA348.v1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 6/2/2022
SUBJECT: HC101322QA348-0001 Amend: 0001
A. TYPE ACTION: AMEND
1. PURPOSE: **THE PURPOSE OF AMEND 0001 IS TO:**
1. UPDATE THE ADDRESS FOR THE CHINA LAKE COMMERCIAL DEMARCATION TO BLDG
2664, RM 101, 1 ADMINISTRATION CIRCLE, CHINA LAKE, CA.
2. UPDATE THE POCS FOR BEALE AFB
3. EXTEND DUE DATE TO 27 JUNE 2022
ALL ELSE REMAINS UNCHANGED
1. SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A 10GB, NON-SWITCHED,
ETHERNET CIRCUIT USING IQO BETWEEN BLDG 2664, RM 101, 1 ADMINISTRATION CIRCLE,
CHINA LAKE, CA AND BLDG 2145, ROOM 105, 5801 C STREET, BEALE AFB, CA
-CONTRACTOR SHALL PROVIDE ETHERNET FRAME SIZE CONFIGURED TO SUPPORT
MAXIMUM TRANSMISSION UNIT (MTU) OF 9000 (BYTES) JUMBO FRAMES
- CONTRACTORS SHALL MEET RTD OF LESS THAN OR EQUAL TO 10 MILLISECONDS PER
350 MILES MEASURED AS THE GREAT CIRCLE DISTANCE BETWEEN THE "A" AND "Z"
LOCATIONS TO SUPPORT THE GOVERNMENT MISSION. IF THE RTD CHANGES IT WOULD BE
NOTIFIED VIA AMENDMENT TO SOLICITATION.
- SEE UNIQUE INSTALL FACTS
- CUSTOMER REQUESTS SOONER, IF POSSIBLE, SERVICE DATE (SIP)
- VENDOR QUOTE MUST INCLUDE THE A LOC AND Z LOC LEC’S ALONG WITH THE
VENDOR’S SUB-CONTRACTOR/LONG-HAUL PROVIDER/CARRIERS FOR THE SERVICE
-VENDOR QUOTES MUST INDICATE IF LEC’S ARE CURRENTLY ON-NET OR IF A BUILD IS
REQUIRED TO COMPLETE THE SERVICE.
- IF A BUILD IS REQUIRED TO COMPLETE THE SERVICE, VENDOR MUST INDICATE THE
SCOPE OF THE BUILD (LENGTH, BURIED/AERIAL, TRENCHING/DIRECTIONAL BORING, NEW
CONDUIT, ETC), AND VENDOR MUST INDICATE IF THE SITE HAS GRANTED PERMISSION
FOR VENDOR TO BUILD INTO THE SITE (MUST ALSO PROVIDE THE SITE POC’S NAME THAT
GRANTED PERMISSION) AND HAS SUFFICIENT SPACE, POWER AND HVAC CAPACITY TO
SUPPORT THE VENDOR EQUIPMENT AND CABLING.
HC101322QA348-0001
2. CONTRACTORS ARE RESPONSIBLE FOR READING AND ADDRESSING ALL TECHNICAL
REQUIREMENTS OF THIS INQUIRY/SOLICITATION, READING AND AGREEING WITH THE
STANDARD PROVISIONS, PROVIDE PRICE QUOTATION IN ACCORDANCE WITH STANDARD
PROVISION 4, AND MEET THE REQUESTED SERVICE DATE.
3.THE SERVICE DATE TO BE MET IS: 26 SEP 22 (SIP) TO COMPLY WITH PROCUREMENT
ACQUISITION LEAD TIME (PALT) FOR THIS TYPE OF SERVICE. ANY CHANGES TO THE
ORIGINAL SERVICE DATE WILL BE NOTIFIED VIA AMENDMENT TO THE SOLICITATION AND
POSTED TO FBO. THE GOVERNMENT ASSUMES THAT CONTRACTORS HAVE CONSIDERED
ALL ISSUES THAT MAY DELAY THE DELIVERY OF CIRCUIT ON REQUESTED SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION IAW
STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE.
4. CONTRACTORS MUST ENSURE THAT QUOTES SHALL INCLUDE SUFFICIENT DETAIL
FOR EFFECTIVE EVALUATION AND SHOULD NOT SIMPLY REPHRASE OR RESTATE THE
GOVERNMENT REQUIREMENTS. RATHER, CONTRACTORS MUST PROVIDE CONVINCING
RATIONALE TO ADDRESS HOW THEY INTEND TO MEET THE REQUIREMENT. IN RESPONSE
TO THIS SOLICITATION, NO TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT,
NOR ASSUMPTIONS WILL BE ACCEPTED. CONTRACTORS ARE INSTRUCTED TO SUBMIT
QUESTIONS AND REQUEST CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE
SUBMITTING QUOTES. QUOTES MUST BE UPLOADED TO IDEAS.
5. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101322QA349/TSR RU07APR227812AND MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS
(SDP) FROM TSR RU07APR227812; MEANING THE PHYSICAL PATHS ARE TOTALLY
SEPARATE INCLUDING MANHOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER
BUILDS. ADDITIONALLY, AS A MINIMUM MUST HAVE 50 METERS / 164 FEET PHYSICAL
SEPARATION FROM TSR RU07APR227812.
6. TO DETERMINE THE AWARDEE(S) OF DIVERSE REQUIREMENTS, THE GOVERNMENT WILL
FIRST EVALUATE THE LOWEST PRICED SOLUTION FOR EACH SOLICITATION. IF THOSE
TWO SOLUTIONS ARE DIVERSE FROM EACH OTHER AND MEET ALL REQUIREMENTS,
AWARD WILL BE MADE TO THE CONTRACTOR OR CONTRACTORS THAT PROPOSED
THE TWO SOLUTIONS. IF THE TWO LOWEST PRICED SOLUTIONS ARE NOT AWARDABLE
BECAUSE THEY ARE NOT DIVERSE FROM EACH OTHER OR DO NOT MEET REQUIREMENTS,
THE GOVERNMENT WILL EVALUATE THE NEXT LOWEST PRICED COMBINATION FOR
BOTH SOLICITATIONS UNTIL IT DETERMINES THE LOWEST PRICED COMBINATION THAT
MEETS ALL REQUIREMENTS. AWARDS WILL BE MADE AS A PAIR TO ONE CONTRACTOR
ONLY OR SPLIT THE AWARD BETWEEN TWO CONTRACTORS THAT MEET ALL TECHNICAL
REQUIREMENTS, REQUESTED SERVICE DATE AND PROPOSE THE LOWEST PRICE.
7. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE ROUTES
FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES AND/OR
WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE
BEING MET. DRAWINGS MUST INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES
AND ROUND-TRIP DELAY BASED ON ACTUAL DISTANCE IN MILES. REFER TO STANDARD
PROVISION 39 FOR SPECIFIC DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS
INCLUDED WITH INQUIRY/SOLICITATION SHALL BE FOLLOWED IN ORDER TO PROVIDE THE
REQUIRED TECHNICAL INFORMATION. MAPS AND DRAWINGS WITH ERRORS, MISMATCH
INFORMATION, MISSING RTD, AND NOT ENOUGH DETAIL TO DETERMINE DIVERSITY
THROUGHOUT THE FIBER PATH WILL BE FOUND TECHNICALLY DEFICIENT AND WILL NOT
BE ACCEPTED. (DO NOT INCLUDE THIS PARAGRAPH IN REQUIREMENTS TO BE WORKED IN
CONJUNCTION/COORDINATION UNLESS MAPS/DRAWINGS ARE REQUIRED).
8. PRE-AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) AND
SHOULD BE CONDUCTED IN COORDINATION WITH LOCAL POCS AT EACH GOVERNMENT
SITE. IT IS HIGHLY RECOMMENDED THAT AT A MINIMUM, CONTRACTORS CONDUCT PHONE
SURVEYS TO ADEQUATELY ASSESS THE MAGNITUDE OF THE WORK TO BE PERFORMED IN
DETERMINING THEIR PRICE STRATEGY.
9. CONTRACTORS MUST ADDRESS IN QUOTES COMPLIANCE WITH TESTING AND
ACCEPTANCE REQUIREMENTS.
10. TESTING & ACCEPTANCE REQUIREMENTS MUST BE COORDINATED WITH CUSTOMER
ACCEPTANCE AUTHORITY BEFORE NOTICE OF COMPLETION IS SUBMITTED TO DITCO. (IF
WORKING DISA ETHERNET, WAVE, SONET (OC-03 AND HIGHER REQUIREMENTS INCLUDE
THE BELOW INFO
FOR DISA REQUIREMENTS THE TESTING AND ACCEPTING AUTHORITY IS:
DISA DSCC IE Mailbox DCP Commercial Activation
11. ESTABLISH TSP: TSP0LMRLV-01
FAILURE TO READ AND ADDRESS ANY OF THE TECHNICAL REQUIREMENTS AND SERVICE
DATE REQUESTED IN THIS INQUIRY SHALL RENDER THE QUOTE NON-COMPLIANT AND
RESULT IN IT BEING EXCLUDED FROM EVALUATION AND AWARD.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: RU07APR227811A
4. CCSD: DIR3B0N2
Z. DITCO CONTACT:
Donna Voss
DONNA.M.VOSS7.CIV@MAIL.MIL
Robert E Spencer
DITCO Contracting Officer
Add the following:
LOCATION OF TERMINATION A:
ADDRESS: BLDG 2664, RM 101
1 ADMINISTRATION CIRCLE
CHINA LAKE, CA
ROOM: 101; 1 FL
LOCATION: CCI
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: 10 GIGABIT ETHERNET; 10GBASE-LR; SUSCRIBERCONNECTOR (SC)
DEMARK: BLDG 2664, RM 101
1 ADMINISTRATION CIRCLE
CHINA LAKE, CA
NPA/NXX: 760/939
UNIQUE INSTALLATION FACTORS: UNIQUE INSTALL:
(1) FIBER CABLE, ON-BASE, SINGLE-MODE, 1310NM, CHINA LAKE PERSONNEL
(2) FIBER TERMINATING PATCH PANEL (GFE) (SITE PROVIDED)
(3) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO.
(4) COMMERCIAL FIBER POINT OF PRESENCE
AMPLIFYING INFO:
A. CHINA LAKE PERSONNEL ARE RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER
FROM LINE SIDE OF SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG 5, ROOM 1000I TO LINE SIDE OF SITE
PROVIDED FIBER TERMINATING PATCH PANEL BLDG 2664, ROOM 101.
B. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM SITE
PROVIDED FIBER PATCH PANEL, BLDG 2664, ROOM 101 TO DROP SIDE OF THE COMMERCIAL FIBER POINT OF
PRESENCE FIBER DISTRIBUTION PANEL (FDP), BLDG 2664, ROOM 101.
C. VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK THROUGH SITE
SURVEY FOR THE EXACT CABLE FT. FROM THE SITE PROVIDED FIBER PATCH PANEL BLDG 2664, ROOM 101 TO THE
COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL (FDP) BLDG 2664, ROOM 101.
D. CIRCUIT MUST BE TAGGED WITH VENDOR'S LONG-HAUL CIRCUIT ID AND LOCAL EXCHANGE CARRIER CIRCUIT
NO. AS APPLICABLE AT DROP SIDE OF THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 2664, ROOM
101. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION
POINT WHEN CIRCUIT INSTALLATION IS COMPLETE.
E. VENDOR MUST SCHEDULE/COORDINATE WITH POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO
SITE SURVEYS OR INSTALLATIONS.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: CPIWI-YES/CPIWM-YES
CONTACT: PRI: ERIC HIGER, D437-6907, C760-939-6907
EMAIL: ERIC.B.HIGER.CIV@MAIL.MIL
ALT: ERIK SISCO, D437-2497, C760-939-2497
EMAIL: ERIK.A.SISCO.CIV@MAIL.MIL
ALT: STEPHAN HARRISON, D437-1865, C760-939-1865
EMAIL: STEPHAN.HARRISON@NAVY.MIL
Add the following:
LOCATION OF TERMINATION B:
ADDRESS: BLDG 2145
5801 C STREET
BEALE AFB, CA, 95903
ROOM: 105; 1 FL
LOCATION: CCI
EXTENSION OF TELECOMMUNICATIONS SERVICE: All facilities between vendor's commercial communications interface point and termination location shall be provided by vendor. All cables shall be run in accordance with local site standards
INTERFACE: 10 GIGABIT ETHERNET; 10GBASE-LR; SUSCRIBERCONNECTOR (SC)
DEMARK: (BLDG) 2145; (RM) 105; (FL) 1
5801 C STREET
BEALE AFB, CA, 95903
NPA/NXX: 530/634
UNIQUE INSTALLATION FACTORS: UNIQUE INSTALL:
(1) COMMERCIAL FIBER POINT OF PRESENCE
(2) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO
AMPLIFYING INFO:
A. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM THE DROP
SIDE OF COMMERCIAL FIBER POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG 2145, ROOM105 TO LINE SIDE
OF DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN CISCO ASR-9010 ROUTER SUITE
(UJEWBEA030) BLDG 2145, ROOM 105. TERMINATE WITH "SC" CONNECTORS TO DISA PROVIDED FIBER
TERMINATING PATCH PANEL.
B. VENDOR MUST PROVIDE FIBER STRANDS FROM THE DISA PROVIDED FIBER PATCH PANEL TO THE DROP SIDE
OF THEIR POP/FIBER DISTRIBUTION PANEL WITHOUT SPLICING AND OR USE OF CONNECTORS TO CONNECT 2 OR
MORE FIBER STRANDS MEANING THE FIBER CANNOT BE BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS.
C. CIRCUIT MUST BE TAGGED WITH VENDOR'S LONG-HAUL CIRCUIT ID AND LOCAL EXCHANGE CARRIER CIRCUIT
NO. AS APPLICABLE AT DROP SIDE OF THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 2145, ROOM
105. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE EXACT TERMINATION
POINT WHEN CIRCUIT INSTALLATION IS COMPLETE.
D. VENDOR MUST SCHEDULE/COORDINATE WITH POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE PRIOR TO
SITE SURVEYS OR INSTALLATIONS.
INSIDE WIRE INSTALLATION / MAINTENANCE REQUIRED: CPIWI-YES/CPIWM-YES
CONTACT: PRI: PLENIO BRION, D368-5480, 530-634-5480
EMAIL: PLENIO.BRIO@US.AF.MIL
ALT: ERIC KASTNER, D368-5464, C530-634-5464
EMAIL: ERIC.KASTNER.1@US.AF.MIL
ALT: MICHAEL MCMURRY, D368-5480, C530-634-5480
EMAIL: MICHAEL.MCMURRY.2@US.AF.MIL
ALT: ERIC DUONG, D368-5480, C530-634-5480
EMAIL: EIRC.DUONG@US.AF.MIL
ORG EMAIL: 9SDS.SDSC@US.AF.MIL
File details come from the government source that posted it. Updated .