TESTING_REQUIREMENTS_FOR_QB152.docx
DOCX document 15 KB Posted
- Solicitation number
- HC101318QB152
- Issued by
-
Defense Information Systems Agency
About this file
Testing Requirements
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation_Vendor_Sample_Block_Diagram_Version3.pdf | ||
| CIRCUIT_PARAMETERS_FOR_QB152.docx | DOCX document | |
| HC101318QB152.v0_(1).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TESTING REQUIREMENTS FOR SOLICITATION HC101318QA991
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS:
LINE RATE: 10GB.
LINE CODE: NRZ
FRAME FORMAT: SCRAMBLED IAW
ANSI T1.104-1991 (R2003)
1. TEST AND ACCEPTANCE: FIBER OPTIC 10GB WAVE CIRCUITS
SHALL PASS A FULLY DOCUMENTED SATISFACTORY SOAK
TEST BY THE CONUS GNOSC AT SCOTT AFB, IL.
PRIMARY: (C) 618-220-8691 (D) 770-8691
2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED
SHALL MEET THE FOLLOWING PERFORMANCE REQUIREMENTS
ON A MONTHLY BASIS.
PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION:
NON-DIVERSE/NON-PROTECTED
AVAILABILITY: GREATER THAN OR EQUAL TO 99.5% OR BETTER.
MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC):
LESS THAN OR EQUAL TO 9
% ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005
% SEVERELY ERRORED SECONDS (SES): LESS THAN OR
EQUAL TO 0.00035
BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN
OR EQUAL TO 5 X 10-6
BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP):
LESS THAN OR EQUAL TO 1 PER 72 HOURS
JITTER SEE NOTE 1 (JITTER)
BER: LESS THAN OR EQUAL TO 1X10-12
DELAY (ONE WAY): * LESSER OF 10 MSEC OR
(0.01 X D MSEC) * WHERE "D" IS THE SDP TO SDP
TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT
CIRCLE, IN KILOMETERS.
3. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER
THE 10GB WAVE CIRCUIT AND SHALL BE LESS THAN OR
EQUAL TO 10 MILLISECONDS.
A. ***ATTENTION TRAVIS AFB AFB LOCATION***
THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END TO THE GOVERNMENT'S SERVICE
DELIVERY POINTS (SDP'S) FROM TSR SF17APR188139;
MEANING THAT THE PHYSICAL PATHS ARE TOTALLY SEPARATE
INCLUDING MAN HOLES, CONDUIT, (CENTRAL OFFICE
LOCATIONS), AND FIBER BUILDS. ADDITIONALLY AS A
MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION FROM
TSR SF17APR188139.
B. TELECOMM PROVIDER MUST PROVIDE DISA COLOR POWERPOINT
DRAWINGS FOR TECHNICAL REVIEW SHOWING THE ROUTES FROM
THE COMMERCIAL DEMARCS TO THE SUPPORING CENTRAL
OFFICES AND OR WIRING CENTERS ENSURING THE PHYSICAL
END TO END DIVERSITY REQUIREMENTS ARE BEING MET.
DRAWINGS ALSO TO INCLUDE SEPARATION DISTANCES,
TOTAL
FIBER MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY
MUST PROVIDE COLOR CODED MAPS AND MUST BE RED LINED
SHOWING HOW THE CIRCIT WILL BE ROUTED END TO END FROM
THE CUSTOMER A LOCATON TO THE CUSTOMER Z LOCATION.
C. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES.
D. SINGLE MODE FIBER MUST BE ENGINEERED/PROVISIONED IN
SUCH A WAY THAT THE GOVERNMENT CAN CHANGE/REVISE
CHANNELIZATION WITHOUT TELECOMM PROVIDER INTERVENTION.
1. NOTE 1 (JITTER).: IN A STEADY-STATE CONDITION,
THE PATTERN OF SYNCHRONOUS TRANSPORT SIGNAL (STS)
POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH
THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE NO
MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH
THE DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI
T1.105.03-1994) THAN THE POINTER ADJUSTMENT
SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING
TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2
TIMES PER DAY), THE PATTERN OF STS POINTER
ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH THE
SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR
OR LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME
INTERVAL ERROR (MTIE) OVER A PERIOD OF S SECONDS,
OR WANDER, SHALL NOT EXCEED (.01S + 10000)
NANOSECONDS FOR VALUES OF S GREATER THAN 10,000.
2. WAVELENGTH TRANSMISSION SERVICES:
WAVELENGTH TRANSMISSION SERVICES FOR RATES
OF 10GBPS SHALL BE IN ACCORDANCE WITH ITU-T
RECOMMENDATIONS G.709(03/2003), G.707(12/03),
G.957(03/06), G.692(10/98) & TELCORDIA GR253-IE4.
THE PROVIDED WAVELENGTH TRANSMISSION SERVICE
SHALL NOT INHIBIT GOVERNMENT OPERATION OF
UNDERLYING PROTOCOLS AND TRANSPORT SYSTEMS
SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP,
ATM, GIGABIT ETHERNET, AND ENCRYPTION. THE
WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL
PASS ALL PAYLOAD, PATH AND LINE OVERHEAD BYTES
TRANSPARENTLY (UNTOUCHED/UNALTERED) AND WITHOUT
MONITORING SDP TO SDP. THERE SHALL NOT BE ANY
LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP
AND SDP.
3. 10GB WAVE SERVICE MUST BE TERMINATED TO THE LINE
SIDE OF THE FIBER TERMINATING PATCH PANEL
INSTALLED IN THE DISA IE1 PROVIDED MSPP SUITE AT
TRAVIS AFB AND THE FIBER TERMINATING PATCH PANEL
INSTALLED IN THE DISA IE1 PROVIDED ODXC SUITE AT
LOS ANGELES AFB.
E. TELECOMM PROVIDER MUST CONTACT DISA CONUS TIER-II
MSPP ENGINEERING UPON RECEIPT OF A VALID TSO TO
ESTABLISH THE COORDINATION AND ACTIVATION PROCESS.
PRI POC: CONTACT: MIKE REEVES
(C) 618-220-8973 (D) 770-8973
ALT POC: CONTACT: DAMION SCANDRICK
(C) 618-220-9634 (D) 770-9634
ALT POC: CONTACT: AARON SMITH
(C) 618-220-9820 (D) 770-9820
ALT POC: CONTACT: BOB RISKY
(C) 618-220-8632 (D) 770-8632
ALT POC: ORGANIZATIONAL NUMBER
(C) 618-220-8691 (D) 770-8691
F. ONCE TELECOMM PROVIDER HAS COMPLETED INSIDE WIRING
FROM THEIR FIBER DISTRIBUTION PANEL INSTALLED IN
THEIR DWDM EQUIPMENT SUITE TO THE GOVERNMENT
SERVICE DELIVERY POINT (SDP) AT EACH LOCATION, THEY
MUST ENSURE THE LIGHT LEVEL READINGS (DB LOSS) ARE
ADJUSTED TO READ -3 TO -9 LOSS. ADDITIONALLY, THESE
LEVELS MUST BE DOCUMENTED ON THE NOTICE OF
COMPLETION (NOC) SENT TO DITCO.
***THE VENDOR MUST TERMINATE SINGLE MODE FIBER AT
BOTH LOCATIONS IAW UNIQUE INSTALLATION FACTORS.***
G. THE SINGLE MODE FIBER MUST PASS A DOCUMENTED
SATISFACTORY 72 HOUR END TO END TEST IAW ITU
STANDARD M.2101 PRIOR TO TURN UP TO THE GOVERNMENT.
H. ANY ADDRESSEE ON THE TSO WILL NOTIFY ALL
ADDRESSEES IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES,
PROBLEMS, OR SITUATIONS WHICH MAY PREVENT OR DELAY THE
IMPLEMENTATION OF THIS TELECOMMUNICATIONS SERVICE ORDER (TSO).
ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT, CONTACT
NUMBERS AND ADDRESSES CONTAINED IN THIS TSO AND PROVIDE UPDATES
TO ORIGINATOR OF TSO ANY ERRORS SO THAT SUBSEQUENT TSOS MAY BE
UPDATED.
I. IMPLEMENTATION ASSISTANCE: FOR DISN CORE / DEDICATED / NIPRNET /
SIPRNET / VPN CIRCUIT ACTIVATION ASSISTANCE OR SERVICE IMPLEMENTA
TION INQUIRIES/SCHEDULING, CONTACT THE DISA GLOBAL RF ACTIVATIONS
TEAM VIA EMAIL, DISA.SCOTT.CONUS.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL
.MIL, OR CALL DSN 770-8627; COML 618-220-8627.
FOR CIRCUIT INSTALLATION ASSISTANCE WITH THE COMMERCIAL LEASED PATH, CONTACT DCP
COMMERICIAL ACTIVATION TEAM (CAT) AT D312-850-0820,
C614-692-0820
J. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED
COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE
SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1
BY THE STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE
ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON
"350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
K. COMPLETION REPORT: SERVICE WILL BE ACCEPTED ON BEHALF OF THE U.S.
GOVERNMENT BYDISA GOC B/B/D770-8627,C618-220-8627 WHO WILL
SUBMIT A COMPLETION REPORT IAW DISAC 310-130-1, CHAP 2 OF DISAC
310-70-1, CHAP 8. REPORT WILL BE ADDRESSED TO THE ORIGINATOR AND
ALL ADDRESSEES OF THIS TSO.
L. UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY
SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING
DISA PROVIDED TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE
DISN CUSTOMER CONTACT CENTER (DCCC) TOLL FREE NUMBER IS
1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML 1-614-692-0032
OPTION 2, DSN 312-850-0032 OPTION 2.