Circuit Parameters

View the file

Other files

File Type Posted
TESTING_REQUIREMENTS_FOR_QB152.docx DOCX document
Solicitation_Vendor_Sample_Block_Diagram_Version3.pdf PDF
HC101318QB152.v0_(1).pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CIRCUIT PARAMETERS FOR SOLICITATION HC101318QA991

CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) FIBER TERMINATION: SINGLE-MODE

INTERFACE REQUIREMENT/INTERFACE DATA RATE:

LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR,

10 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991

(R2003). ALL OPTIONS DEFINED SC CONNECTOR,

SINGLE-MODE FIBER PER ANSI T1.105.06-2002

(SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).

(B) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE

TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT

LEAST 99.5% OR BETTER.

(C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR

TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.

(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO

BE ENGINEERED INTO CIRCUIT.

(E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS

(F) NO NETWORK INTERFACE UNIT.

(G) DEDICATED PATH.

(H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO

ASSIST IN ANY CIRCUIT OUTAGES.

(I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY

END TO END TEST ON THE 10 WAVE SERVICE IAW ITU

STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST

SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST

RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE

ACCEPTING AUTHORITY FOR REVIEW.

(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL

CENTER.

(K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON

BEHALF OF THE GOVERNMENT BY THE CONUS GNOSC:

PRI POC: CONTACT: MIKE REEVES

(C) 618-220-8973 (D) 770-8973

ALT POC: CONTACT: DAMION SCANDRICK

(C) 618-220-9634 (D) 770-9634

ALT POC: CONTACT: AARON SMITH

(C) 618-220-9820 (D) 770-9820

ALT POC: CONTACT: BOB RISKY

(C) 618-220-8632 (D) 770-8632

ALT POC: ORGANIZATIONAL NUMBER

(C) 618-220-8691 (D) 770-8691

(L) THE VENDOR MUST PROVIDE:

1. THE LONG HAUL CIRCUIT

NUMBER AND THE 1-800 TROUBLE REPORT NUMBER TO THE

ACCEPTING AUTHORITY PRIOR TO THE GOVERNMENT

ACCEPTING SERVICE. INSIDE WIRING MUST BE

COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR

TO TURNUP TO THE GOVERNMENT.

2. VENDOR IS RESPONSIBLE FOR INSTALLATION AND

MAINTENANCE OF 10GB WAVE SERVICE IAW UNIQUE

INSTALLATION FACTORS.

3. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE

INSTALLATION FACTORS.

4. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS

IN ADVANCE PRIOR TO REQUIRING ACCESS TO FACILITIES AT

BOTH USER LOCATIONS. IF UNABLE TO REACH SITE POC'S

CONTACT KEN DIEF OR RAY BURKE FOR ASSISTANCE AT:

(301) 225-2416/2550.

5. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT

AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED

TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE DISN

CUSTOMER CONTACT CENTER (DCCC) SCOTT AFB, IL.

TOLL FREE: 1-855-868-9500

COML: 618-220-9500 DSN: 312-770-9500

6. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW

DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL.

GUIDANCE ON SUBMISSION IS AVAILABLE AT

CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE

COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."