Hasse-Emery Park Improvements - Details 2026.pdf

PDF 12 MB Posted

Attached to
RFP-546916 Hasse-Emery Park Improvement
Solicitation number
546916
Issued by
Wayne County, Detroit City, Michigan

About this file

This is a detailed specifications and standards document prepared by the City of Detroit General Services Department for the Hasse-Emery Park Improvement project. The document establishes comprehensive technical requirements for landscape improvements, tree care, site furnishings, playground equipment installation, and hardscape work at the park. The scope of work includes removal and pruning of trees, planting of new vegetation in accordance with American Association of Nurserymen standards, installation of concrete and asphalt walkways, placement of playground equipment from manufacturers such as Kompan, site amenities including benches and picnic tables, perimeter fencing, and specialized surface materials such as engineered wood fiber and play sand. All plant materials must be installed using a specified soil mix of 50% existing soil, 30% sandy loam topsoil, and 20% compost, with City Representative approval required for soil conditions prior to planting. The contractor must provide three-business-day advance notice for planting coordination and coordinate with Miss Dig 72 hours prior to any excavation work to mark utilities. All subgrades must be compacted to 95%, and site amenities require City Representative approval before installation.

The document specifies that all plant materials must conform to American Association of Nurserymen standards with a one-year warranty period, during which plants must be watered a minimum of six times throughout the first planting season, with any defective plants replaced at no cost to the City during the following planting season. All hardware and bolts must be stainless steel unless supplied by manufacturers, with bolt threads cut to a maximum of three visible threads for security purposes. Contractors must supply and apply theft deterrent products such as Loc-Tight to all applicable site amenities. Tree protection fencing of high-density polyethylene with steel posts installed at eight-foot intervals must remain in place until construction completion. Mulch material must be double-shredded hardwood bark placed at a minimum three-inch depth, and pre-emergent herbicide must be applied to planting beds prior to mulch placement. The contractor bears responsibility for viewing the site before bidding and noting any special conditions, with all costs for site coordination, materials, and labor included in the proposal price.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. All plants to be installed in accordance with American Association of Nurserymen (A.A.N.)

Landscape Standards.

2. Fertilizer shall be M-Roots 3-3-3 or City Representative approved organic fertilizer(s) with Mycorrhiza(s) and applied to the plant mix according to Manufacturer's Directions.

3. Contractor shall provide a Plant Mix consisting of 50% existing soil, 30% sandy loam topsoil and 20% compost. The City Representative shall be allowed two weeks to receive any and all required soil test results. No plants shall be planted prior to City Representative approval of soil conditions.

4. Backfilling of all voids from removal work shall be with sandy loam topsoil and existing approved site soils. Discovered site concrete, gravel or other non-soil(s) will not be acceptable.

5. Spacing of plant materials shall be as shown on drawing, City Representative reserves the right to modify all plant and bed locations prior to planting at no additional cost to the City. The contractor must coordinate the layout and planting three business days in advance with City Representative so that coordination of the planting on that day is not hampered.

6. Refer to specifications for additional requirements.

7. All plants shall bear the same relationship to finished grade as the plants original grade before digging.

8. No container grown stock will be accepted if it is root bound. Any and all wrapping materials made of synthetics or plastics shall be completely removed prior to the time of planting.

9. All plant pits must be a minimum of twice the root ball or container diameter.

10. Contractor shall fill plant pit with prepared plant mix to ½ depth of root ball or root mass, pack mix firmly and puddle with water.

11. For balled and burlaped material, the burlap and all lacing (including wire basket if present) shall be removed from the upper-half of the root ball, then finish backfilling with plant mix. Removal all excess soil from top of root ball that is above the Original Nursery Grade.

12. A saucer shall be placed around every plant and shall be approved prior to the placement of any geo-textile fabric or mulch.

13. All plant materials shall conform to plant schedules. Sizes shall be the minimum stated on the plant list or larger. All measurements shall be in accordance with the latest editions of the "A.A.N.

Standards For Nursery Stock."

14. Contractor shall apply City Representative approved pre-emergent herbicide to planting beds following plant installation and prior to mulch placement. The Contractor shall ensure the plant materials are resistant to the herbicides properties. Herbicide shall be applied according to

Manufacturers Specifications and in accordance with sound horticultural practices.

15. All mulch material shall be placed at a minimum depth of 3" and shall be double-shredded hardwood bark. No mulch shall be placed on plants trunks.

16. Refer to Specifications for Lawn Restoration and Establishment to provide acceptable established turf.

17. All plant materials shall be inspected upon arrival. Any plants not acceptable to the City Representative will be rejected. If for any reason any balled and burlaped plant materials need to be stored on site longer than a 24-hour period, their root balls shall be protected by a City Representative approved method. All plants shall be thoroughly watered each day they are stored on site. Any plants allowed to dry out will be rejected.

18. Plant materials, especially evergreens, shall be planted higher than normal when heavy soil conditions (clay, etc.) prevail.

19. All planting beds shall be prepared with appropriate soil mixtures and fertilizer before plant installation.

20. Natural edging shall consist of a 6 x 6 inch trench filled with mulch.

21. Any discrepancies between the plans and specifications shall be immediately reported to the City Representative for his review and decision.

22. Contractor shall supply all plant materials in quantities sufficient to complete the planting shown on all drawings.

23. No plant shall be put into the ground before rough grading has been finished and approved by the City Representative.

24. All plants and stakes shall be set plumb unless otherwise specified. All guys and stakes must be located within each trees' mulched area to eliminate the possibility of mower contact and to reduce maintenance.

25. Staking of the shrubs is not anticipated. However, if it is determined by the City Representative that staking is required, the contractor shall stake all desired plants at no additional cost to the City.

26. Contractor shall be responsible for viewing the site prior to bidding making note of any special conditions that would be a concern to this part of the contract.

27. Contractor shall provide a one year warranty on all plant materials and any plants that are determined by the City Representative to be defective at his or her own discretion must be replaced.

Replacement must be done during the following planting season. All plants are to be watered thoroughly a minimum of six times the first planting season.

STANDARD PLANTING NOTES CONTENTS

PART IV B: STANDARD DETAIL DRAWINGS CITY OF DETROIT

GENERAL

SERVICES

DEPARTMENT

18100 Meyers Rd

313-628-0900

PAGE DESCRIPTION

Cover Page 1 - Standard Construction Notes Cover Page 2 - Standard Planting Notes Cover Page 3 - Standard Backfill & Top Soil Notes

L5.01 Surfacing Details L5.02 Site Amenity Details L5.03 Site Furniture Details L5.04 Site Furniture II Details L5.05 Fitness Equipment Details L5.06 Playground Equipment Details L5.07 Playground Equipment II Details L5.08 Playground Equipment III Details L5.09 Perimeter Details L5.10 Landscaping and Materials Details

The document below is an abbreviated version of the Detroit Building Authority's, "Guidance for Backfill Material Evaluation and Testing, City of Detroit Demolition Program, December 18, 2014" (Guidance). The Guidance was reviewed and approved by the Detroit Buildings, Safety Engineering and Environmental Department (BSEED) Environmental Affairs, and reviewed by MDEQ and EPA.

NOTE:ONLY CATEGORY 1 & 2 ARE SUITABLE FOR PARK USE!

This guidance is intended to support the City of Detroit and any of its operating entities during its managed residential and commercial demolition related activities, specifically as it relates to review and approval of “Clean Fill” for backfill activities conducted by Contractors. Furthermore, these guidelines have been established to ensure that backfill material used by Contractors is “Clean Fill”, and safe for use in residential and/or commercial demolition areas.

The purpose of this guidance is to provide the City of Detroit and its Demolition Contractors with guidance for approving and relocating backfill materials. The following categories are those that are applicable to City Parks:

Category 1: Residential Construction and Residential Landscape Yard Sites

Category 2: Virgin (Native) Commercial Borrow and Sand/Gravel Pit Sites

At this time, no chemical testing is required for excess soil relocated from Category 1 or 2 Type sources.

Further, excess soil relocated from Category 1 or 2 sources will be considered acceptable as backfill material at demolition sites provided the following conditions are met:

1. For Category 1 Sites: A written certification from the Contractor to GSD.

2. For Category 2 Sites: A written certification from the Owner/Operator.

The written certification must include at a minimum the following affirmative statements:

• the origin of the backfill material and address location

• no evidence of known or suspected sources of environmental contamination that may have impacted the proposed backfill materials

• the backfill materials are from a native soil source and are homogeneous in nature and general composition

• the backfill materials are free from debris, large rocks, concrete, or other conditions which would make the material unsuitable for use as backfill, and meet the backfill specifications established by the City of Detroit

Contractors must provide the following information (in an email to GSD's Project Manager) before relocating backfill material from a Category 1 or 2 Type source:

1. Provide affirmative statements as described above

2. Proposed end use location (property address(es), block addresses, or lot numbers) of the relocated source of the backfill material

Approval and relocation of Category 1 and 2 Type Backfill Materials are conditioned upon submittal of the information described above. Notification must be provided electronically and in advance to GSD City Representative:

For Category 1 Type Backfill Materials, the Contractor will be notified immediately of approval. Contractor shall submit as appropriate weekly backfill tracking logs electronically showing end use location, quantities, etc.

For Category 2 Type Backfill Materials, DBA or its designated Backfill Program Manager (GSD Project Manager) will review the information provided within 24 hours or less of the request, and either approve the backfill materials for use at DBA (GSD) sites, request additional information, or deny the proposed backfill material source. Upon approval, DBA (GSD) or its designated Backfill Program Manager will issue a certificate of approval to the Contractor, and the Contractor shall to submit weekly backfill tracking logs electronically showing end use location, quantities, etc.

STANDARD BACKFILL & TOP SOIL NOTES CONTENTS

PAGE DESCRIPTION

Cover Page 1 - Standard Construction Notes Cover Page 2 - Standard Planting Notes Cover Page 3 - Standard Backfill & Top Soil Notes

L5.01 Surfacing Details L5.02 Site Amenity Details L5.03 Site Furniture Details L5.04 Site Furniture II Details L5.05 Fitness Equipment Details L5.06 Playground Equipment Details L5.07 Playground Equipment II Details L5.08 Playground Equipment III Details L5.09 Perimeter Details L5.10 Landscaping and Materials Details

PART IV B: STANDARD DETAIL DRAWINGS CITY OF DETROIT

GENERAL

SERVICES

DEPARTMENT

18100 Meyers Rd

313-628-0900

NOTES:

· STRICTLY ADHERE TO MANUFACTURER'S INSTALLATION PROCEDURES AND DETAILS

· STRICTLY ADHERE TO MANUFACTURER'S INSTILLATION INSTRUCTIONS FOR FOOTING LOCATIONS

· LANDSCAPE ARCHITECT SHALL VERIFY ORIENTATION OF PLAY STRUCTURES IN THE FIELD

· CONTRACTOR SHALL NOT PROCEED IN UNCERTAINTY. MANUFACTURER'S REPRESENTATIVE

SHALL BE REQUIRED TO BE ON SITE DURING INSTALLATION OF EQUIPMENT AND PLAY SURFACE

· ALL REBAR TO BE EPOXY COATED.

FOR FILE

PROJ #:

PROP #:

DIST #:

CHECKED:

SHEET TITLE:

APPROVED:DRAWN:

GENERAL SERVICES DEPARTMENT

LANDSCAPE DESIGN UNIT

18100 MEYERS RD, DETROIT MI 48235

PH: (313) 628-0900 FAX:(313) 628-0927

SHEET

DATE

PROJECT NAME:

ISSUED FOR

SCALE:

HASSE-EMERY PARK

IMPROVEMENTS

3/24/26

SESC AND TREE

CARE DETAILS

L5.01

RL

JK

JK

N.T.S.

1. DO NOT SCALE OFF THE DRAWINGS,

DETAILS ARE NOT TO SCALE.

2. CHECK ALL MANUFACTURER'S

SPECIFICATIONS AND DRAWINGS FOR

FURTHER DETAILED INFORMATION.

3. CONTRACTOR TO SUPPLY AND

APPLY LOCK TIGHT OR OTHER

APPROVED THEFT DETERRENT

PRODUCT TO ALL SITE AMENITIES

WHERE APPLICABLE.

4. ALL BOLTS SHALL BE CUT OR

SAWED SO THERE IS A MAXIMUM OF 3

THREADS VISIBLE.

5. IF NOT SUPPLIED BY THE

MANUFACTURER ALL HARDWARE

SHALL BE PURCHASED AND INSTALLED

(STAINLESS STEEL) BY THE

CONTRACTOR.

6. ALL SITE AMENITIES SHALL BE

LAYED OUT AND APPROVED BY THE

CITY REPRESENTATIVE PRIOR TO

INSTALLATION.

7. ALL SUBGRADES SHALL BE

COMPACTED TO 95%.

8. CALL MISS DIG 72 HOURS (3

WORKING DAYS) PRIOR TO ANY

CONSTRUCTION OR EXCAVATION TO

MARK ALL UTILITIES. (800) 482-7171

TREE PRUNING

NOT TO SCALEL5.01

NOT TO EXCEED

REMOVE SUCKER SHOOTS

AT BASE OF TREE

MAKE CLEAN CUTS ON OLD

STUBS, IF PRESENT

REMOVE ENTIRE SUPPLY OF

TWIGS AND BUDS ON TRUNK

REMOVE LOWER BRANCH WHERE

AN OVERLYING BRANCH OCCUPIES

ABOUT THE SAME AREA

SHAPE TREE BY REMOVING INJURED

AND MISSHAPEN BRANCHES

REMOVE CROSS BRANCHES AND

THOSE DEVELOPING INTO

SECONDARY LEADERS

REMOVE BROKEN AND DEAD

BRANCHES

NOTE: BRANCHES IN DASHED LINES

INDICATE THOSE TO BE REMOVED

2' MIN.

SECTION A - A'

A A'

NOT TO SCALE

INLET FABRIC DROP1

L5.01

PLAN

NOT TO SCALE

TREE PROTECTION UNDER DRIP LINE

4'

NOTES:

NO PRUNING SHALL BE PERFORMED EXCEPT BY APPROVED CITY

REP.

NO EQUIPMENT SHALL OPERATE INSIDE THE PROTECTION FENCE

INCLUDING AND DURING FENCE INSTALLATION AND REMOVAL.

FENCE SHALL REMAIN UNTIL CONSTRUCTION IS COMPLETE.

TREE PROTECTION FENCE:

HIGH DENSITY POLYETHYLENE

FENCING WITH 3.5" X 1.5"

OPENINGS; COLOR ORANGE.

STEEL POSTS INSTALLED AT 8'

O.C.

2" X 6" STEEL POSTS OR

APPROVED EQUIVALENCE

MAINTAIN EXISTING GRADE WITH

THE FENCE PROTECTION FENCE

UNLESS OTHERWISE INDICATED

ON THE PLANS

L5.01

AutoCAD SHX Text

6" MIN. OVERLAP AT END OF SILT FENCE

AutoCAD SHX Text GEOTEXTILE BLANKET INSTALLED BETWEEN COVER AND FRAME OF DRAINAGE STRUCTURE CASTING

AutoCAD SHX Text

DRAIN INLET /COVER

AutoCAD SHX Text

DRAIN INLET/COVER

AutoCAD SHX Text GEOTEXTILE BLANKET INSTALLED BETWEEN COVER AND FRAME OF DRAINAGE STRUCTURE CASTING

AutoCAD SHX Text

SILT FENCE

1/4"

CONTROL/EXPANSION JOINTS

NOT TO SCALE

L5.02

1. DO NOT SCALE OFF THE DRAWINGS,

DETAILS ARE NOT TO SCALE.

2. CHECK ALL MANUFACTURER'S

SPECIFICATIONS AND DRAWINGS FOR

FURTHER DETAILED INFORMATION.

3. CONTRACTOR TO SUPPLY AND

APPLY LOCK TIGHT OR OTHER

APPROVED THEFT DETERRENT

PRODUCT TO ALL SITE AMENITIES

WHERE APPLICABLE.

4. ALL BOLTS SHALL BE CUT OR

SAWED SO THERE IS A MAXIMUM OF 3

THREADS VISIBLE.

5. IF NOT SUPPLIED BY THE

MANUFACTURER ALL HARDWARE

SHALL BE PURCHASED AND INSTALLED

(STAINLESS STEEL) BY THE

CONTRACTOR.

6. ALL SITE AMENITIES SHALL BE

LAYED OUT AND APPROVED BY THE

CITY REPRESENTATIVE PRIOR TO

INSTALLATION.

7. ALL SUBGRADES SHALL BE

COMPACTED TO 95%.

8. CALL MISS DIG 72 HOURS (3

WORKING DAYS) PRIOR TO ANY

CONSTRUCTION OR EXCAVATION TO

MARK ALL UTILITIES. (800) 482-7171

4" CONCRETE PAVEMENT

NOT TO SCALE

L5.02

NOT TO SCALE

TYPICAL BACKFILL7

L5.02

DEPTH VARIES

WIDTH VARIES

FOR FILE

PROJ #:

PROP #:

DIST #:

CHECKED:

SHEET TITLE:

APPROVED:DRAWN:

GENERAL SERVICES DEPARTMENT

LANDSCAPE DESIGN UNIT

18100 MEYERS RD, DETROIT MI 48235

PH: (313) 628-0900 FAX:(313) 628-0927

SHEET

DATE

PROJECT NAME:

ISSUED FOR

SCALE:

HASSE-EMERY PARK

IMPROVEMENTS

3/24/26

SURFACING

DETAILS

L5.02

RL

JK

JK

N.T.S.

EWF WITH DRAINAGE SYS., CONCRETE WALKWAY, AND BORDER

NOT TO SCALE

L5.02

ASPHALT PAVING

NOT TO SCALE

1 12" BITUMINOUS MIXTURE NO. 1100T,

20AA

BITUMINOUS TACK COAT -

APPLICATION RATE PER MANUF.

SPECS.

UNDISTURBED SUBGRADE

2 12" BITUMINOUS MIXTURE NO. 1100L,

20AA

8" MIN. COMPACTED AGGREGATE

BASE: MDOT 21AA (DEPTH VARIES

BASED ON SUBGRADE CONDITIONS)

L5.02

L5.02

SAND PIT W/ CONCRETE BORDER & DRAINAGE SYS.

NOT TO SCALE

12" APPROX. APPROVED PLAY SAND FINISHED

DEPTH

RESTORE LAWN TO EXISTING GRADE, 14" -1/2'

BELOW CURB

STEEL REBAR 0.2"

4 OUNCE GEOTEXTILE FABRIC TYP.

4" AGGREGATE SUBBASE (PEA GRAVEL)

4" PERFORATED PVC PIPE W/ SOCK

UNDISTURBED SUBGRADE

CONCRETE BORDER, 12" DEEP X 8" WIDE OR 12"

WIDE W/ (1) RADIUS (1.5") ROUND CORNER

4 OUNCE GEOTEXTILE FABRIC TYP.

L5.02

EWF WITH CONCRETE BORDER & DRAINAGE SYS.

NOT TO SCALE

12" MIN ENGINEERED WOOD FIBER FINISHED

DEPTH AFTER COMPACTION

CONCRETE BORDER, 12" DEEP X 8" WIDE W/ (1)

RADIUS (1.5") ROUND CORNER

RESTORE LAWN TO EXISTING GRADE, 14" -1/2'

BELOW CURB

STEEL REBAR 0.2"

GEOTEXTILE FABRIC TYP.

4" AGGREGATE SUBBASE

4" PERFORATED PVC PIPE W/ SOCK

UNDISTURBED SUBGRADEUNDISTURBED SUBGRADE

12" MIN ENGINEERED WOOD FIBER FINISHED

DEPTH AFTER COMPACTION

CONCRETE BORDER, 12" DEEP X 8" WIDE W/ (1)

RADIUS (1.5") ROUND CORNER

4" DEEP X WIDTH VARIES CONCRETE WALK/PAD

4" AGGREGATE SUBBASE

STEEL REBAR 0.2"

GEOTEXTILE FABRIC TYP.

4" AGGREGATE SUBBASE

4" PERFORATED PVC PIPE W/ SOCK

AutoCAD SHX Text

CONCRETE PAVEMENT

AutoCAD SHX Text 1/2"

AutoCAD SHX Text

CONCRETE PAVEMENT

AutoCAD SHX Text

ASPHALTIC EXP. JOINT MATERIAL (PER SPECS.)

AutoCAD SHX Text

BACKER ROD

AutoCAD SHX Text

2-PART POLY-SEALANT

AutoCAD SHX Text

CONTROL JOINT

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

SAW CUT

AutoCAD SHX Text

OR APPROVED TOOL JOINT

AutoCAD SHX Text 1/2" FULL DEPTH PREFORMED BITUMINOUS EXPANSION JOINT, FLEXCELL, RECESSED 1/2" FROM SURFACE, LOCATE 50' O.C. OR AS SHOWN ON PLANS.

AutoCAD SHX Text 4"

AutoCAD SHX Text

SURFACE TREATMENT- BROOM FINISH, EXCEPT AS INDICATED ON PLAN

AutoCAD SHX Text

4" CONCRETE PAVEMENT

AutoCAD SHX Text

CONCRETE CURING COMPOUND

AutoCAD SHX Text

4" MED./FINE LIMESTONE OR COMPACTED SAND (95% COMPACTION)

AutoCAD SHX Text 4"

AutoCAD SHX Text

FINISHED GRADE

AutoCAD SHX Text

MINIMUM 4" TOP SOIL

AutoCAD SHX Text

APPROVED FILL SOIL

AutoCAD SHX Text

UNDISTURBED COMPACTED SUBGRADE

FINISH GRADE

FOR FILE

PROJ #:

PROP #:

DIST #:

CHECKED:

SHEET TITLE:

APPROVED:DRAWN:

GENERAL SERVICES DEPARTMENT

LANDSCAPE DESIGN UNIT

18100 MEYERS RD, DETROIT MI 48235

PH: (313) 628-0900 FAX:(313) 628-0927

SHEET

DATE

PROJECT NAME:

ISSUED FOR

SCALE:

HASSE-EMERY PARK

IMPROVEMENTS

3/24/26

SITE AMENITY

DETAILS

L5.03

RL

JK

JK

N.T.S.

1. DO NOT SCALE OFF THE DRAWINGS,

DETAILS ARE NOT TO SCALE.

2. CHECK ALL MANUFACTURER'S

SPECIFICATIONS AND DRAWINGS FOR

FURTHER DETAILED INFORMATION.

3. CONTRACTOR TO SUPPLY AND

APPLY LOCK TIGHT OR OTHER

APPROVED THEFT DETERRENT

PRODUCT TO ALL SITE AMENITIES

WHERE APPLICABLE.

4. ALL BOLTS SHALL BE CUT OR

SAWED SO THERE IS A MAXIMUM OF 3

THREADS VISIBLE.

5. IF NOT SUPPLIED BY THE

MANUFACTURER ALL HARDWARE

SHALL BE PURCHASED AND INSTALLED

(STAINLESS STEEL) BY THE

CONTRACTOR.

6. ALL SITE AMENITIES SHALL BE

LAYED OUT AND APPROVED BY THE

CITY REPRESENTATIVE PRIOR TO

INSTALLATION.

7. ALL SUBGRADES SHALL BE

COMPACTED TO 95%.

8. CALL MISS DIG 72 HOURS (3

WORKING DAYS) PRIOR TO ANY

CONSTRUCTION OR EXCAVATION TO

MARK ALL UTILITIES. (800) 482-7171

NOT TO SCALE

TYPICAL SURFACE MOUNT1

L5.03 NOT TO SCALE

TYPICAL IN-GROUND MOUNT2

L5.03 NOT TO SCALE

L5.03

SIDE VIEW

NOTE:

*ALL FINISHES TO BE POWDER COATED BLACK

TO BE CENTER ON 4' X 4' CONCRETE SLAB

ANTI-TIPPING RING FOR TRASH RECEPTACLE

D 25 14"

H 11"

NOT TO SCALE

6' BENCH

L5.03

SOURCE: DUMOR

6' BENCH, 56-60D, DOUGLAS FUR,

SURFACE MOUNT

NOT TO SCALE

6' PICNIC TABLE

L5.03

SOURCE: DUMOR

6' PICNIC TABLE, 75-60D,

DOUGLAS FUR, SURFACE MOUNT

SOURCE: DUMOR

6' BENCH, 56-60D, DOUGLAS FUR,

SURFACE MOUNT

AutoCAD SHX Text

STAINLESS STEEL EXP. BOLT.

AutoCAD SHX Text

4" MIN. COMPACTED SAND BASE

AutoCAD SHX Text

5.5" MIN. CONCRETE SLAB

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text

BOLT SIZED PER MFR.

AutoCAD SHX Text

RECOMMENDATION - 5/16" MIN.

AutoCAD SHX Text

EMBED BOLT 3"

AutoCAD SHX Text

APPROVED THIEFT DETERANT

AutoCAD SHX Text

UNDISTURBED COMPACTED SUBGRADE

AutoCAD SHX Text

42" MIN.

AutoCAD SHX Text

30" MIN.

AutoCAD SHX Text

PER MFR.

AutoCAD SHX Text

4" MIN. SAND BASE

AutoCAD SHX Text

4" MIN. CONCRETE SLAB

AutoCAD SHX Text

CONCRETE FOOTING

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text

EMBED FOOTING 30" MIN.

AutoCAD SHX Text

INCLUDE SLIGHT CROWN ON TOP OF FOOTING

AutoCAD SHX Text

TOP VIEW

AutoCAD SHX Text RING: 1 " STEEL ANGLE IRON (MIN. 7 GAUGE OR 3/16" THICK)14" STEEL ANGLE IRON (MIN. 7 GAUGE OR 3/16" THICK)

AutoCAD SHX Text FEET: 2 " 34" HOLES: " (TO ACCOMMODATE " CONCRETE BOLTS)12" (TO ACCOMMODATE " CONCRETE BOLTS)38" CONCRETE BOLTS)

AutoCAD SHX Text LEGS: 1 " STEEL ANGLE IRON (MIN. 7 GAUGE OR 3/16" THICK)14" STEEL ANGLE IRON (MIN. 7 GAUGE OR 3/16" THICK)

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS.

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS.

NOT TO SCALE

THE WIZARD'S HIDEAWAY ADA

NOTES:

· STRICTLY ADHERE TO MANUFACTURER'S INSTALLATION PROCEDURES AND DETAILS

· STRICTLY ADHERE TO MANUFACTURER'S INSTILLATION INSTRUCTIONS FOR FOOTING

LOCATIONS

· LANDSCAPE ARCHITECT SHALL VERIFY ORIENTATION OF PLAY STRUCTURES IN THE FIELD

· CONTRACTOR SHALL NOT PROCEED IN UNCERTAINTY. MANUFACTURER'S REPRESENTATIVE

SHALL BE REQUIRED TO BE ON SITE DURING INSTALLATION OF EQUIPMENT AND PLAY SURFACE

· ALL REBAR TO BE EPOXY COATED.

FOR FILE

PROJ #:

PROP #:

DIST #:

CHECKED:

SHEET TITLE:

APPROVED:DRAWN:

GENERAL SERVICES DEPARTMENT

LANDSCAPE DESIGN UNIT

18100 MEYERS RD, DETROIT MI 48235

PH: (313) 628-0900 FAX:(313) 628-0927

SHEET

DATE

PROJECT NAME:

ISSUED FOR

SCALE:

HASSE-EMERY PARK

IMPROVEMENTS

3/24/26

PLAYGROUND EQUIP.

DETAILS

L5.04

RL

JK

JK

N.T.S.

1. DO NOT SCALE OFF THE DRAWINGS,

DETAILS ARE NOT TO SCALE.

2. CHECK ALL MANUFACTURER'S

SPECIFICATIONS AND DRAWINGS FOR

FURTHER DETAILED INFORMATION.

3. CONTRACTOR TO SUPPLY AND

APPLY LOCK TIGHT OR OTHER

APPROVED THEFT DETERRENT

PRODUCT TO ALL SITE AMENITIES

WHERE APPLICABLE.

4. ALL BOLTS SHALL BE CUT OR

SAWED SO THERE IS A MAXIMUM OF 3

THREADS VISIBLE.

5. IF NOT SUPPLIED BY THE

MANUFACTURER ALL HARDWARE

SHALL BE PURCHASED AND INSTALLED

(STAINLESS STEEL) BY THE

CONTRACTOR.

6. ALL SITE AMENITIES SHALL BE

LAYED OUT AND APPROVED BY THE

CITY REPRESENTATIVE PRIOR TO

INSTALLATION.

7. ALL SUBGRADES SHALL BE

COMPACTED TO 95%.

8. CALL MISS DIG 72 HOURS (3

WORKING DAYS) PRIOR TO ANY

CONSTRUCTION OR EXCAVATION TO

MARK ALL UTILITIES. (800) 482-7171

SOURCE: KOMPAN

MODEL # NRO40901 CUSTOM

FSC VARIANT

L5.04

NOT TO SCALE

JEEP 4 X 4

L5.04

NOT TO SCALE

VILLAGE HOUSE

L5.04

SOURCE: KOMPAN

MODEL # NRO563-1001

SOURCE: KOMPAN

MODEL # NRO40501-0601

NOT TO SCALE

DOUBLE SWING COMBINATION

L5.04

SOURCE: KOMPAN

MODEL # NRO924 CUSTOM FSC VARIANT

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

NOT TO SCALE

FOREST BUG SPRINGER

NOTES:

· STRICTLY ADHERE TO MANUFACTURER'S INSTALLATION PROCEDURES AND DETAILS

· STRICTLY ADHERE TO MANUFACTURER'S INSTILLATION INSTRUCTIONS FOR FOOTING

LOCATIONS

· LANDSCAPE ARCHITECT SHALL VERIFY ORIENTATION OF PLAY STRUCTURES IN THE FIELD

· CONTRACTOR SHALL NOT PROCEED IN UNCERTAINTY. MANUFACTURER'S REPRESENTATIVE

SHALL BE REQUIRED TO BE ON SITE DURING INSTALLATION OF EQUIPMENT AND PLAY SURFACE

· ALL REBAR TO BE EPOXY COATED.

FOR FILE

PROJ #:

PROP #:

DIST #:

CHECKED:

SHEET TITLE:

APPROVED:DRAWN:

GENERAL SERVICES DEPARTMENT

LANDSCAPE DESIGN UNIT

18100 MEYERS RD, DETROIT MI 48235

PH: (313) 628-0900 FAX:(313) 628-0927

SHEET

DATE

PROJECT NAME:

ISSUED FOR

SCALE:

HASSE-EMERY PARK

IMPROVEMENTS

3/24/26

PLAYGROUND EQUIP.

DETAILS II

L5.05

RL

JK

JK

N.T.S.

1. DO NOT SCALE OFF THE DRAWINGS,

DETAILS ARE NOT TO SCALE.

2. CHECK ALL MANUFACTURER'S

SPECIFICATIONS AND DRAWINGS FOR

FURTHER DETAILED INFORMATION.

3. CONTRACTOR TO SUPPLY AND

APPLY LOCK TIGHT OR OTHER

APPROVED THEFT DETERRENT

PRODUCT TO ALL SITE AMENITIES

WHERE APPLICABLE.

4. ALL BOLTS SHALL BE CUT OR

SAWED SO THERE IS A MAXIMUM OF 3

THREADS VISIBLE.

5. IF NOT SUPPLIED BY THE

MANUFACTURER ALL HARDWARE

SHALL BE PURCHASED AND INSTALLED

(STAINLESS STEEL) BY THE

CONTRACTOR.

6. ALL SITE AMENITIES SHALL BE

LAYED OUT AND APPROVED BY THE

CITY REPRESENTATIVE PRIOR TO

INSTALLATION.

7. ALL SUBGRADES SHALL BE

COMPACTED TO 95%.

8. CALL MISS DIG 72 HOURS (3

WORKING DAYS) PRIOR TO ANY

CONSTRUCTION OR EXCAVATION TO

MARK ALL UTILITIES. (800) 482-7171

SOURCE: KOMPAN

MODEL # NRO112-0421

L5.05

NOT TO SCALE

BEE SPRINGER2

NOT TO SCALE

PLAY PANEL 2, MUSIC

L5.05

L5.05

SOURCE: KOMPAN

MODEL # NRO613-1001

SOURCE: KOMPAN

MODEL # NRO118-0401

NOT TO SCALE

GAS PUMP - CUSTOMIZE "#3"

L5.05

SOURCE: KOMPAN

MODEL # NRO513-1021

NOT TO SCALE

GAS STATION W/ 2 PUMPS

L5.05

SOURCE: KOMPAN

MODEL # NRO511-0601

NOT TO SCALE

PLAY PANEL 3 - LEARNING

L5.05

SOURCE: KOMPAN

MODEL # NRO615-1001

SOURCE: KOMPAN

MODEL # NRO212-0501

NOT TO SCALE

KIDS TABLE W/ 4 SITTING STUMPS3

L5.05

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

AutoCAD SHX Text

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR FOOTINGS AND LOCATIONS.

· STRICTLY ADHERE TO MANUFACTURER'S INSTILLATION INSTRUCTIONS FOR FOOTING LOCATIONS

· LANDSCAPE ARCHITECT SHALL VERIFY ORIENTATION OF PLAY STRUCTURES IN THE FIELD

· CONTRACTOR SHALL NOT PROCEED IN UNCERTAINTY. MANUFACTURER'S REPRESENTATIVE

SHALL BE REQUIRED TO BE ON SITE DURING INSTALLATION OF EQUIPMENT AND PLAY SURFACE

· ALL REBAR TO BE EPOXY COATED.

FOR FILE

PROJ #:

PROP #:

DIST #:

CHECKED:

SHEET TITLE:

APPROVED:DRAWN:

GENERAL SERVICES DEPARTMENT

LANDSCAPE DESIGN UNIT

18100 MEYERS RD, DETROIT MI 48235

PH: (313) 628-0900 FAX:(313) 628-0927

SHEET

DATE

PROJECT NAME:

ISSUED FOR

SCALE:

HASSE-EMERY PARK

IMPROVEMENTS

3/24/26

PERIMETER

DETAILS

L5.06

RL

JK

JK

N.T.S.

1. DO NOT SCALE OFF THE DRAWINGS,

DETAILS ARE NOT TO SCALE.

2. CHECK ALL MANUFACTURER'S

SPECIFICATIONS AND DRAWINGS FOR

FURTHER DETAILED INFORMATION.

3. CONTRACTOR TO SUPPLY AND

APPLY LOCK TIGHT OR OTHER

APPROVED THEFT DETERRENT

PRODUCT TO ALL SITE AMENITIES

WHERE APPLICABLE.

4. ALL BOLTS SHALL BE CUT OR

SAWED SO THERE IS A MAXIMUM OF 3

THREADS VISIBLE.

5. IF NOT SUPPLIED BY THE

MANUFACTURER ALL HARDWARE

SHALL BE PURCHASED AND INSTALLED

(STAINLESS STEEL) BY THE

CONTRACTOR.

6. ALL SITE AMENITIES SHALL BE

LAYED OUT AND APPROVED BY THE

CITY REPRESENTATIVE PRIOR TO

INSTALLATION.

7. ALL SUBGRADES SHALL BE

COMPACTED TO 95%.

8. CALL MISS DIG 72 HOURS (3

WORKING DAYS) PRIOR TO ANY

CONSTRUCTION OR EXCAVATION TO

MARK ALL UTILITIES. (800) 482-7171

NOT TO SCALE

BOULDER

L5.06

NOTE:

FLAT SURFACE SIDE TO BE PLACED ON THE GROUND. SIZE TO BE

3'-4' ON ALL HORIZONTAL AND VERTICAL SIDES

NOT TO SCALE

4' PARK SIGN INSTALLATION

L5.06

NOTE:

Sign shall be 12" thick single-sided or double-sided phenolic-fused panel

" N

O M

. H T.

" N

O M

. H T.

NOT TO SCALE

4' HT STAGGERED FENCE W/ CONCRETE MAINT. STRIP - CUSTOM

L5.06

4X4 CEDAR POSTS NO. 1

STRUCTURAL SET STRAIGHT

AND PLUMB. CHAMFER TOP OF

POST, 4 SIDES

2X2, 2X4 AND 2X6 CEDAR PLANKS,

PLANED ON ALL SIDES

OFFSET PLANKS FOR 1.5" GAP,

STAGGER AND ALTERNATE

PATTERN AS SHOWN

2X4 CEDAR RAIL, (3) REQ'D W/

EQ. SPACING, ATTACH W/

STAINLESS STEEL SCREWS

POWDER-COATED POST BASE

(E-Z BASE) REQUIRED TO

SECURE POST, STRAIGHT AND

PLUMB TO CONCRETE FOOTING;

USE STAINLESS STEEL

ANCHORS AND SCREWS

" H

T

PO

ST

T

Y P.

78"

4" X 24" CONCRETE MAINT.

STRIP WHERE INDICATED

4" COMPACTED SAND

COMPACTED SUBGRADE

CONCRETE FOOTING FOR

CORNER AND END POSTS TYP.

FR

O

ST

D

EP

TH

2"

1" COMPOSITE PLASTIC

STANDOFF COLUMN BASE TO

SIT AT FINISH GRADE

UNDISTURBED SUBGRADE

" H

T

PL

A N

K

" H

T

PL

A N

K

" H

T

PL

A N

K

3" GAP

1.5" TYP.

8"

8"

3"

5"

12" X 24"

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text 36"

AutoCAD SHX Text 72"

AutoCAD SHX Text

48X20 GRAPHIC PANEL

AutoCAD SHX Text

CENTER OF WELDED PLATE WITH 1/2" DIA.

AutoCAD SHX Text

MOUNTING BRACKET

AutoCAD SHX Text

ANCHOR BOLTS, SET WITH TEMPLATE

AutoCAD SHX Text

CONTROL JOINT

AutoCAD SHX Text

12"X12" MOUNTING PLATES

AutoCAD SHX Text

MOUNTING HOLES 1.5" FROM EDGES

AutoCAD SHX Text

4" STEEL SINGLE POST POWDER COATED IN SATIN BLACK

AutoCAD SHX Text

WITH 2"X2" ALUMINUM ANGLED WELDED TO INSIDE OF POST

AutoCAD SHX Text

MIN 3/16" WALL THICKNESS AT POST

AutoCAD SHX Text

COMPACTED TOPSOIL AND LAWN

AutoCAD SHX Text 12"

AutoCAD SHX Text

4" CONCRETE MAINTENANCE STRIP

AutoCAD SHX Text

6" SAND BASE COURSE

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text 6"

AutoCAD SHX Text 52.375"

AutoCAD SHX Text 20"

AutoCAD SHX Text

48X20 GRAPHIC PANEL

AutoCAD SHX Text

(FINISH SHALL BE FLUSH)

AutoCAD SHX Text 9"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text

4" MIN. FROM CENTER OF

AutoCAD SHX Text

BOLT TO O.D. OF FOOTING

AutoCAD SHX Text

1/2" X 6" STAINLESS STEEL

AutoCAD SHX Text

J OR EXPANSION BOLT

AutoCAD SHX Text

48X6 OPTIONAL GRAPHIC PANEL

AutoCAD SHX Text

4" SQ.PLATE WELDED AT TOP

AutoCAD SHX Text

MIN 3/16" WALL THICKNESS AT POST

AutoCAD SHX Text 60"

AutoCAD SHX Text 8"

AutoCAD SHX Text

8" THICKENED

AutoCAD SHX Text

CONCRETE

AutoCAD SHX Text

COMPACTED SUBGRADE

AutoCAD SHX Text

BOULDER SIZE: 4' MIN. ON ALL SIDES

AutoCAD SHX Text

INSTALL BOULDERS 5.5' END OF BOULDER TO BEGINNING OF NEXT

BURY BOULDERS OF ITS 13 OF ITS HEIGHT

· STRICTLY ADHERE TO MANUFACTURER'S INSTILLATION INSTRUCTIONS FOR FOOTING LOCATIONS

· LANDSCAPE ARCHITECT SHALL VERIFY ORIENTATION OF PLAY STRUCTURES IN THE FIELD

· CONTRACTOR SHALL NOT PROCEED IN UNCERTAINTY. MANUFACTURER'S REPRESENTATIVE

SHALL BE REQUIRED TO BE ON SITE DURING INSTALLATION OF EQUIPMENT AND PLAY SURFACE

· ALL REBAR TO BE EPOXY COATED.

FOR FILE

PROJ #:

PROP #:

DIST #:

CHECKED:

SHEET TITLE:

APPROVED:DRAWN:

GENERAL SERVICES DEPARTMENT

LANDSCAPE DESIGN UNIT

18100 MEYERS RD, DETROIT MI 48235

PH: (313) 628-0900 FAX:(313) 628-0927

SHEET

DATE

PROJECT NAME:

ISSUED FOR

SCALE:

HASSE-EMERY PARK

IMPROVEMENTS

3/24/26

LANDSCAPE

DETAILS

L5.07

RL

JK

JK

N.T.S.

1. DO NOT SCALE OFF THE DRAWINGS,

DETAILS ARE NOT TO SCALE.

2. CHECK ALL MANUFACTURER'S

SPECIFICATIONS AND DRAWINGS FOR

FURTHER DETAILED INFORMATION.

3. CONTRACTOR TO SUPPLY AND

APPLY LOCK TIGHT OR OTHER

APPROVED THEFT DETERRENT

PRODUCT TO ALL SITE AMENITIES

WHERE APPLICABLE.

4. ALL BOLTS SHALL BE CUT OR

SAWED SO THERE IS A MAXIMUM OF 3

THREADS VISIBLE.

5. IF NOT SUPPLIED BY THE

MANUFACTURER ALL HARDWARE

SHALL BE PURCHASED AND INSTALLED

(STAINLESS STEEL) BY THE

CONTRACTOR.

6. ALL SITE AMENITIES SHALL BE

LAYED OUT AND APPROVED BY THE

CITY REPRESENTATIVE PRIOR TO

INSTALLATION.

7. ALL SUBGRADES SHALL BE

COMPACTED TO 95%.

8. CALL MISS DIG 72 HOURS (3

WORKING DAYS) PRIOR TO ANY

CONSTRUCTION OR EXCAVATION TO

MARK ALL UTILITIES. (800) 482-7171

NOT TO SCALE

TREE PLANTING1

L5.07

TREE SHALL CONFORM TO ANSI-Z60.1

STANDARD FOR SIZING, FORM, AND ROOT

BALL CONDITION.

CONTRACTOR TO PRUNE BROKEN

BRANCHES ONLY, PER SPECIFICATIONS

AND ANSI A300 STANDARD, TO RESTORE

PLANT TO REQUIRED QUALITY. DO NOT

PRUNE CENTRAL LEADER.

TREE SHALL BE SET PLUMB AND TRUE.

CONTRACTOR IS RESPONSIBLE FOR

MAINTAINING SAID CONDITION THROUGH

WARRANTY PERIOD.

IF NECESSARY, STAKING AND GUYING IS

RESPONSIBLE AND MAINTAINED BY THE

CONTRACTOR; AND SHALL BE REMOVED

BY THE SAME NO LATER THAN THE END OF

THE WARRANTY PERIOD UNLESS

OTHERWISE NOTED.

PLANTING PIT 2-3X ROOT BALL

TREE CALIPER / HEIGHT

MEASUREMENT SHALL

MEET ANSI-Z60.1

STANDARD CURRENT

EDITION FOR ROOT BALL

SIZE

NURSERY MARK

NORTH SIDE OF

TREE, TYP.

ROOT BALL MODIFIED AS REQUIRED

PER SPECIFICATIONS. SET ATOP

UNDISTURBED GRADE.

TRUNK FLARE TO BE FLUSH WITH

FINISHED GRADE

SOIL SAUCER AT PERIPHERY OF

BRANCHING ATOP FINISHED GRADE

MULCH RING PER

SPECIFICATIONS AND NOTES

FINISHED GRADING

AMENDED BACKFILL - SEE NOTES

AND SPECIFICATIONS. LIGHTLY

COMPACT AND WATER TO

ELIMINATE VOIDS.UNDISTURBED SUBGRADE

NOT TO SCALE

STEPPING BOULDER

L5.07

NOTE:

FLAT SURFACE SIDE TO BE PLACED ON THE GROUND. SIZE TO BE

15"-18" IN DIAMETER.

UNDISTURBED SUBGRADE

AutoCAD SHX Text

WIDTH VARIES

AutoCAD SHX Text BOULDER SIZE: 15"-18" MIN. IN DIA. BOULDER TO BE SMOOTH, ROUNDED, AND FREE OF SHARP EDGES

BURY BOULDER

Sheets and Views
Hasse-Emery Park Improvements - Details-Cover Sheet 2
Hasse-Emery Park Improvements - Details-Cover Sheet 3
Hasse-Emery Park Improvements - Details-L5.01 SESC and Tree Care Details
Hasse-Emery Park Improvements - Details-L5.02 Surfacing
Hasse-Emery Park Improvements - Details-L5.03 Site Amenity
Hasse-Emery Park Improvements - Details-L5.04 Playground Eq
Hasse-Emery Park Improvements - Details-L5.05 Playground Eq
Hasse-Emery Park Improvements - Details-L5.06 Perimeter
Hasse-Emery Park Improvements - Details-L5.07 Landscape and Materials

File details come from the government source that posted it. Updated .