SUBMITTED BY:
APPROVED BY:
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
EASTERN SERVICE AREA – NEW YORK TECHNICAL SUPPORT CENTER
VOR
REPLACEMENT OF THE VOR BUILDING ROOF
DETAILS
HANCOCK HANCOCK NY
DWG NO REV
HNK-D-VOR
SHEET A002 DATE
09/15/2022
NOTES:
1. INSTALL WALKING PADS AROUND PERIMETER OF TEEPEE, AROUND PERIMETER OF ROOF, FROM THE LADDER
TIE DOWN POINT TO THE TEEPEE AND INSIDE THE TEEPEE.
2. CONTRACTOR SHALL REMOVE AND RE-INSTALL ALL VOR MONITORING ANTENNAS IN THE SAME LOCATION.
3. ROTTED T&G ROOF DECKING SHALL BE REPLACED AS NECESSARY
4. THE CONTRACTOR SHALL ENSURE THAT THE FACILITY REMAINS PROTECTED FROM THE WEATHER AT ALL TIMES. CAUTION SHALL BE USED WHEN WORKING AROUND THE VOR ANTENNAS LOCATED INSIDE THE TEEPEE
5. THE CONTRACTOR HAS THE OPTION OF EITHER USING THE COPPER MESH OR INSTALLING A 16OZ PER SQUARE FOOT COPPER COUNTERPOISE/TERNE PLATE. ALL LAP JOINTS SHALL BE 3/4" ANS SOLDERED FULL LENGTH AND
WIDTH.
6. CONTRACTOR SHALL INSPECT BUILDING INTERIOR CEILING AND REPLACE THE DAMAGED AREA
PAINT EXPOSED WOOD
DECK AND NAILER WHITE
WITH EXTERIOR PAINT
CONTRACTOR SHALL FURNISH AND INSTALL 16 MONITOR ANTENNA
SUPPORT ASSEMBLIES AT LOCATIONS SET BY THE SURVEY LAYOUT
REPLACEMENT OF THE VOR BUILDING
MONITOR ANTENNA SUPPORT ASSEMBLY
HANCOCK HANCOCK NY
SHEET S001 DATE
Page-1�
2023-01-04T13:44:31-0500
JOSEPH C HENN
2023-01-05T11:03:52-0500
MICHAEL M. SHUCAVAGE
REPLACEMENT OF THE VOR BUILDING
ROOF PLAN
HANCOCK HANCOCK NY
SHEET C001 DATE
16 VOR ANTENNA
MONITORS (TYP)
REMOVED BY THE
FAA
N
MAG
1. CONTRACTOR TO REMOVE THE 16 VOR ANTENNA MONITOR ANTENNAS AND MOUNTING
PLATES. CONTRACTOR TO STORE THE ANTENNAS AND PLATES ON-SITE. THE ANTENNAS AND
PLATES SHALL BE REINSTALLED IN THE SAME EXACT LOCATION UPON COMPLETION OF THE
INSTALLATION OF THE NEW ROOFING SYSTEM. A NYS LICENSED SURVEYOR SHALL BE USED
TO RECORD THE EXSITING LOCATION OF THE MONITOR ANTENNA AND LAYOUT THE FINAL
LOCATION/ORIENTATION.
2. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS OF SHELTER AND ROOF.
3. CONTRACTOR TO PROPERLY STORE AND SECURE THE VOR TEEPEE WHEN ON THE
GROUND.
REMOVE EXISTING ROOFING SYSTEM
DOWN TO THE EXISTING METAL
TERNEPLATE AND INSTALL NEW FULLY
ADHERED EPDM ROOFING SYSTEM.
R 26'-5"
INSTALL WALKWAY PADS AROUND
ENTIRE PERIMETER OF TEEPEE
INSTALL WALKWAY PADS
AROUND ENTIRE
PERIMETER OF ANTENNAS
(REMAINDER NOT SHOWN
FOR CLARITY)
EXISTING GROUND CABLE TO
REMAIN. REMOVE AND RE-ATTACH
AS NEEDED FOR INSTALLING NEW
ROOFING SYSTEM (4 PLACES)
REMOVE AND SAVE
ANTENNA MOUNTING/
KEYSTONE BRACKETS,
FABRICATE NEW
SUPPORT ASSEMBLY
AND REINSTALL
BENEATH ROOF DECK
(16 TOTAL) SEE S001
36' X 36' X 10'
SHELTER
UNBOLT AND REMOVE FIBERGLASS VOR ANTENNA TEEPEE.
REINSTALL TEEPEE IN SAME EXACT LOCATION AFTER NEW ROOF
IS INSTALLED. IF NECESSARY, REMOVE TOP COVER TO ALLOW
FOR PROPER REMOVAL OF THE TEEPEE. CONTRACTOR TO
REMOVE ALL EXISTING GASKETS/CAULKING MATERIAL AND CLEAN
ALL SURFACES TO ALLOW FOR PROPER INSTALLATION OF NEW
GASKET AND CAULKING R 5'-0"
22.5 DEGREES
Page-1�
2023-01-04T13:43:02-0500
JOSEPH C HENN
2023-01-05T11:00:33-0500
MICHAEL M. SHUCAVAGE
PROFILE DETAILS
HANCOCK HANCOCK NY
SHEET A002 DATE
REMOVE FIBERGLASS TEEPEE AND REINSTALL OVER NEW ROOFING SYSTEM.
INSTALL REFERENCE MARKINGS TO ENSURE TEEPEE IS REINSTALLED IN THE
PROPER LOCATION (CENTERED ON ROOF). TEEPEE SHALL BE PROPERLY
SECURED AND STORED WHEN ON THE GROUND. ANY DAMAGE SUSTAINED
DURING THE MOVING/STORAGE OF THE TEEPEE SHALL BE REPAIRED BY THE
CONTRACTOR AT NO ADDITIONAL COST.
EXISTING COPPER BOND STRIP
EXISTING VOR
MOUNTING RING
WALKING PADS (TYP)
INSTALL FULLY ADHERED ROOF
MEMBRANE
INSTALL ¾” EXTERIOR GRADE PLYWOOD AND FASTEN PER ROOF
MANUFACTURER SPECIFICATONS
EXISTING GROUNDING CONDUCTORS TO REMAIN (4 TOTAL)
1. INSTALL WALKING PADS AROUND PERIMETER OF TEEPEE, AROUND PERIMETER OF ROOF, FROM THE LADDER
TIE DOWN POINT TO THE TEEPEE AND INSIDE THE TEEPEE.
2. CONTRACTOR SHALL REMOVE AND RE-INSTALL ALL VOR MONITORING ANTENNAS IN THE SAME LOCATION. A STATE OF NY LICENSED SURVEYOR SHALL BE USED TO RECORD THE EXISITNG LOCATION AND ORIENTATION OF
EACH ANTENNA AND THEN CONFIRM THE FINAL LOCATION.
3. THE CONTRACTOR SHALL ENSURE THAT THE FACILITY REMAINS PROTECTED FROM THE WEATHER AT ALL TIMES. CAUTION SHALL BE USED WHEN WORKING AROUND THE VOR ANTENNAS LOCATED INSIDE THE TEEPEE
EXISTING TERNE PLATE TO REMAIN
ROOFING PROFILE DETAILS
26'-5"
R O
O F
C
EN
TE
R
LI
E
EXISTING VINYL SOFFIT BETWEEN ROOF EDGE
AND BUILDING (DIMENSION VARIES) TO REMAIN
REPLACE DAMAGED INTERIOR
CEILING PANELS AND PAINT TO
MATCH EXISTING COLOR
INSTALL TEMINATION BAR IN ACCORDANCE WITH MANUFACTURER
SPECIFICATIONS
VOR BUILDING WALL
EXISTING VINYL SIDING AND INSULATION BOARD TO
REMAIN
EXISTING 2" X 6" TONGUE AND
GROVE DECKING
EXISTING ROOF DECK
BLOCKING
2" X 12" FACIA BOARD WITH WHITE
FLASHING TO REMAIN
PAINT EXPOSED NAILER AND BOTTOM OF ROOF BOARDS WITH PRIMER AND 2 COATS
OF EXTERIOR ACRYLIC LATEX WHITE PAINT PRIOR TO INSTALLATION OF THE
MONITORING ANTENNA BRACKETS. NAILERS SHALL BE DRY AND ABLE TO ACCEPT THE
PAINT. DO NOT PAINT WHILE NAILER IS UNABLE TO ABSORB THE PAINT. TOUCH UP AS
NECESSARY AFTER INSTALLATION OF THE BRACKETS.
EXISTING ROOF SUPPORT
CHANNELS AND STEEL BEAMS VOR BUILDING CEILING PANELS
EXTEND PLYWOOD AND MEMBRANE INTO TEEPEE
INSTALL RUBATEX GASKET BETWEEN TEEPEE BASE AND ROOF
MEMBRANE. USE CONTACT ADHESIVE TO HOLD GASKET IN PLACE
IF REQUIRED
INSTALL CAULKING AROUND TEEPEE PERIMETER
(INSIDE AND OUTSIDE). CAULKING MUST BE
COMPATABLE WITH THE ROOFING MEMBRANE
(polyurethane-based elastomeric sealant 3M 5200)
INSTALL 4' LONG 2" X 8" PRESSURE TREATED NAILER (TRIM AS NECESSARY TO
FIT BETWEEN BUILDING FACIA AND ROOF EDGE) CENTERED AT EACH
MONITORING ANTENNA LOCATION (16 TOTAL) USING 6 EQUALLY SPACED
GALVANIZED LAG SCREWS. SEE S001 FOR MONITORING ANTENNA BRACKET
SUPPORT FABRICATION MOUNTING DETAILS.DIM VARIES
X
X
INSTALL ADHESIVE/MASTIC IN ACCORDANCE WITH ROOF
MANUFACTURER SPECIFICATIONS
INSTALL SEALANT IN ACCORDANCE WITH ROOF MANUFACTURER
SPECIFICATIONS
SAND OR CHAMFER TOP EDGE OF PLYWOOD (ENTIRE PERIMETER)
SECURE TEEPEE USING EXISTING 3/8" LAG BOLTS AND WASHERS.
CONTRACTOR TO REPLACE ANY DAMAGED LAG BOLTS AT NO
ADDITIONAL COST. INSTALL CAULKING IN THE PILOT HOLES
(36 TOTAL)
Page-1�
2023-01-04T13:43:45-0500
JOSEPH C HENN
2023-01-05T11:02:46-0500
MICHAEL M. SHUCAVAGE
KELSEY, NY
HANCOCK (HNK) VOR/DME
REPLACEMENT OF VOR BUILDING ROOF
EASTERN SERIVCE AREA – NEW YORK TECHNICAL SUPPORT CENTER
COVER
KELSEY HANCOCK VOR NY
HNK-D-BLDG
SHEET G001DATE
11/29/2022
Page-1�
2023-01-04T13:40:21-0500
JOSEPH C HENN
2023-01-05T10:53:57-0500
MICHAEL M. SHUCAVAGE
INDEX
KELSEY HANCOCK VOR NY
HNK-D-BLDG
SHEET G002DATE
11/29/2022
DRAWING LIST ABBREVIATIONS SYMBOLS LEGEND
GENERAL
G001 TITLE
G002 INDEX
G003 PHOTOS
CIVIL
C001 ROOF PLAN
C002 ROOF PROFILE
STRUCTURAL
S001 MONITOR ANTENNA SUPPORT ASSEMBLY
EES EARTH ELECTRODE SYSTEM
EMT ELECTRICAL METALLIC CONDUIT
FAA FEDERAL AVIATION ADMINISTRATION
GFM GOVERNMENT FURNISHED MATERIAL
JB JUNCTION BOX
PVC-RGSC PVC COATED RIGID GALVANIZED STEEL CONDUIT
RE RESIDENT ENGINEER
RF RADIO FREQUENCY
RGSC RIGID GALVANIZED STEEL CONDUIT
SS STAINLESS STEEL
SYMBOL DESCRIPTIONNOTES
A1
DETAIL CALLOUT
DETAIL
NUMBER
SHEET WHERE
DETAIL IS DRAWN
REFERENCE PLANE
A-1
A-1
SECTION
SECTION
NUMBER
SHEET WHERE
SECTION IS DRAWN
Page-1�
2023-01-04T13:41:37-0500
JOSEPH C HENN
2023-01-05T10:56:50-0500
MICHAEL M. SHUCAVAGE
PHOTOS
KELSEY HANCOCK VOR NY
SHEET G003 DATE
09/07/2022
Page-1�
2023-01-04T13:42:30-0500
JOSEPH C HENN
2023-01-05T10:58:21-0500
MICHAEL M. SHUCAVAGE
File details come from the government source that posted it. Updated .