Habersham HS Riser 6_21_24.pdf

PDF 305 KB Posted

Attached to
HCBOE Theater Lighting Upgrade
Solicitation number
PE-55091-NONST-2025-000000009
Issued by
Habersham County, Georgia

About this file

This document is a lighting system riser for the Habersham Central High School Performing Arts Center in Clarksville, Georgia. The project involves upgrading the lighting system in the auditorium to a new LED lighting system. The scope of work includes the installation of a CISCO 28-port switch with PoE, a 24-port patch panel, and various electrical and lighting control components such as sensors, modules, touchscreens, and gateways. The project also requires wiring and cabling according to specific protocols and maximum lengths. This work is being procured by the Habersham County Board of Education.

The document does not provide details on pricing, set-asides, incumbents, funding sources, or other commercial terms. It appears to be a technical specification rather than a solicitation document.

View the file

Other files

File Type Posted
Contractor Affidavit Attachment B.pdf PDF
HCBOE Theater Lighting Upgrade RFP.pdf PDF
Attachment A.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CISCO 28-PORT SWITCH WITH PoE

24-PORT PATCH PANEL

3Ø, 4 WIRE + GND

120 / 208 VAC

60Hz.

(BY EC)

SENSOR3 SR3-24

1 - CEM3 MODULE

15 - D20 MODULES

9 - R20 MODULES

PAGE

400A. MAX.

ELECTRICAL SYSTEMS ASSOCIATED WITH THE

LIGHTING CONTROL SYSTEM HEREIN ARE FOR

REPRESENTATION ONLY.

ELECTRICAL POWER DISTRIBUTION MUST BE

SPECIFIED AND DIRECTED BY THE ELECTRICAL

ENGINEER OF RECORD FOR THIS PROJECT.

P-TS7-WM PARADIGM 7" TOUCHSCREEN

BLK FLSH

STAGE MANAGER STATION

UNISON UH10002

LOBBY

UV

UNISON UH10002

LOBBY

UV UV UVUV

UV

UNISON UH10010

AUDITORIUM

UNISON UH10010

AUDITORIUM

UNISON UH10010

STAGE LEFT

UNISON UH10010

STAGE RIGHT

P-TS7-WM PARADIGM 7" TOUCHSCREEN

BLK FLSH

CONTROL ROOM

SENSOR IQ48

3Ø, 4 WIRE + GND

120 / 208 VAC

60Hz.

(BY EC)

48 - 1 POLE BREAKERS

1 - DOOR - SURFACE

400A. MAX.

EQUIPMENT RACK BY OTHERS

120V / 60 Hz.

20A MAX.

(BY EC)

1Ø, 2 WIRE + GND

UNISON ERn2-RM

ARCHITECTURAL CONTROL UNIT

1 - P-SPM-E

1 - P-ACP

RESPONSE 4-PORT GATEWAY

RESPONSE 4-PORT GATEWAY (DUAL)

NG

NG

TO HOUSE LIGHTS AND POCKETS

SEE PANEL SCHEDULE FOR DETAILS

NET

NET

TO ELECTRICS AND POCKETS

SEE PANEL SCHEDULE FOR DETAILS

BRUSH PANEL 1U

DMX OUT PLUG-IN

FOH #1 HL

NET PLUG-IN

SM STATION

1Ø, 2 WIRE + GND

NORMAL/EMERGENCY FEED

100-277VAC 50/60Hz.

20A. MAX.

(BY OTHERS)

DEBC-6

HOUSE LIGHT DMX

DMX OUT PLUG-IN

FOH #2 HL

DMX OUT PLUG-IN

FOH #3 HL

DMX OUT PLUG-IN

FOH #5 HL

DMX OUT PLUG-IN

FOH #4 HL

NET/NET PLUG-IN

BOOTH

CONTROL WIRING LEGEND

(1) TMB PC244T

(1) TMB PCLP2PT

(1) BELDEN #1583A + (1) #14 AWG GND WIRE

(2) #16 AWG. STRANDED WIRES

NOTES

1.) ALL CONTROL WIRING IS PROVIDED BY EC

UNLESS NOTED OTHERWISE.

2.) ALL ETCNet RUNS SHALL BE CONTINUOUS, UNSPLICED RUNS LESS THAN 300' (90M). ALL

NETWORK CONNECTIONS TO BE TIA/EIA 568B.

3.) TOTAL COMBINED LENGTH OF UNISON/ECHO

WIRING RUNS CANNOT EXCEED 1640' (500M).

UNISON MAY BE HOMERUN, STAR, 'T', OR DAISY

CHAINED.

4.) DMX FIXTURE RUNS MUST DAISY CHAIN AND

CANNOT EXCEED 1640' (500M) IN LENGTH. DO NOT

EXCEED QUANTITY OF 32 DEVICES IN ONE DMX

CHAIN.

5.) DMX IN/OUT PLUG LOCATIONS SHALL BE

CONTINUOUS, UNSPLICED RUNS LESS THAN 1640'

(500M).

6.) RELABEL AND REUSE EXISTING CONNECTOR

STRIPS AND FLOOR/WALL POCKETS.

(UNISON OR ECHO + (2) 16 AWG VOLTAGE

+ (1) 14 AWG GND WIRE)

(DMX)

(ETCNet with GROUND- Cat5e)

(PANIC)

DMX

NG

UV

P

(1) BELDEN 8489

(BLUESSYSTEM CTRL+PWR+GND)

BS

(1) BELDEN #FI3D006R9

(FIBER)

F

(1) BELDEN #1583A

(ETCNet - Cat5e)

NET

NET PLUG-IN

HOUSE

NET PLUG-IN

FOH #2 ELECTRIC

NET PLUG-IN

FOH #1 ELECTRIC

NET PLUG-IN

FOH #1 ELECTRIC

NET PLUG-IN

FOH #2 ELECTRIC

NET PLUG-IN

1ST ELECTRIC

NET PLUG-IN

1ST ELECTRIC

NET PLUG-IN

2ND ELECTRIC

NET PLUG-IN

2ND ELECTRIC

NET PLUG-IN

3RD ELECTRIC

NET PLUG-IN

3RD ELECTRIC

NET

NET

NET

NET

NET

NET

NET

NET

NET

NET

NET

NET

NET

NET

DMX

DMX

DMX

DMX

DMX

DMX

ADDED GATEWAYS

TYPICAL OF 5

(MOUNTED ON ELECTRICS)

RSN-DMX2-O-P

OUT OUT

C-CLAMP

SAFETY CABLE

A R

C H

IT

E

C T:

SESCO LIGHTING

E N

G

IN

E E

R

D E

S

IG

N E

R

IN

TE

G R

A

TO

R

D R

A W

N B

Y

DESCRIPTION:

PAGE:

C H

E K

E D

B Y www.sescolighting.com

5100 Peachtree Industrial Blvd. Suite 400 Peachtree Corners, Georgia 30071 Tel: (770) 449-7045

P R

O

JE

C T:

R E V

D E S C R

IP

TI

O N

D A

TE

B Y

LIGHTING SYSTEM

RISER

H A

B E

R S

H A

M C

E N

TR

A

L H

IG

H

S C

H O

O L

C

LA

R K

S V

IL

LE

, G A

A S

H

LE

Y P

IT

TM

A N

O G

D R

A W

IN

G

A T

Q U

O

TE

5/

/2

A R

P A

FI

X

T P

A C

K A

G E

C H

A N

G E

S 6/

/2

A

R P

Sheets and Views
17 X 11
11x17