This document is a set of questions and answers related to a Request for Quote (RFQ) for a SCBA air compressor system. The key details are:

The solicitation is for One (1) Open Circuit Air Storage System, Eight (8) Air Tanks, and Installation to be delivered to Fort Carson, Colorado by August 15, 2024. The RFQ provides detailed technical specifications for the air compressor system, including requirements around dimensions, pressure, charging rate, monitoring systems, hose reel, emergency stop, electrical, warranty, training, and installation. The government has indicated this is replacing an existing nonfunctioning system and has provided pictures of the current setup as an attachment. All questions must be submitted by July 15, 2024, and quotes are due by July 19, 2024. The solicitation is being issued by the United States Special Operations Command.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H92421-24-Q-0006

Industry Questions and Government Answers

10th SFG Open Air System

# Document Para/Section Question/ Response

1 RFQ

52.212-1 and

52.212-2

Q. We would need more information to quote. Data sheets , specs, drawings, etc.

Q. Are you able to forward us the specifications?

Q. [Do you have] an example of air compressor requirements to include in the solicitation? Example: Minimum Specs Required:

A:

1. The specifications are brand name or equal to “EagleAir® Model 70B70046BH70 ASME Air Storage System”.

2. Compressor and fill station must be an all-in-one sound dampening system.

3. Breathing air compressor size not to exceed overall dimensions of L101” x W38” x H80”

4. Must have 6000 psig working pressure, a minimum charging rate of 13.0 CFM, and minimum 10HP motor.

5. Must have CO and H2S monitoring system with audible alarm, and air purification system.

6. Must have a forward hinged 3-position containment fill station.

7. Must have a touchscreen color display.

8. Must have 100’ high pressure enclosed hose reel.

9. Must have emergency stop push button and automatic stop/start control.

10. Must include two ASME 6000 psi cylinders with valve and capability to add two additional cylinders.

11. Noise shall not exceed 72 DB at one meter.

12. Must meet the following electrical requirements

a. 208 three phase electric

b. 65 amps

13. Must be able to support unscheduled warranty maintenance within 24-48 hours after notification of service.

a. Must include factory warranty consisting of at least the following:

i. Manufactured compressors, compressor systems and accessory equipment are warrantied for twenty-four (24) months minimum from date of equipment installation and acceptance.

14. Must include installation. All installation and cleanup activities and end user training must be completed within one 40-hour work week Tuesday-Friday between 0700-1700 hours.

15. Pricing must include freight and shipping.

16. Must include, at a minimum, 1-day user level operation and maintenance training.

2 RFQ 52.212-2

Q. Did the writers of the contract mean “Emergency Breathing Air Compressor” (EBAC) or SCBA air compressor?

A. The requirement is for a SCBA air compressor.

3 RFQ 52.212-2

Q. What is the NSN for the item?

A. This is a commercial item without an NSN.

4 RFQ 52.212-2

Q. Is this to replace an existing system?

A. Yes. This requirement is replacing a nonfunctioning system.

5 RFQ 52.212-2

Q. Can you post a picture of the existing system or install location?

A. Yes. This is to replace an existing system. We have included pictures of the existing system as “Attachment 1” of Amendment 1 to the Solicitation.