H3WA15- 60EX Explosion Proff Boom Lifts -Item Description.pdf
PDF 148 KB Posted
- Attached to
- H3WA15 60' Explosion Proof Boom Lifts. Federal contract opportunity
- Solicitation number
- FA813223Q0002
About this file
This memorandum provides specifications for two 60-foot explosion proof boom lifts required by the 76th Air and Space Expeditionary Wing. The boom lifts must be certified for use in Class I, Division I hazardous environments and be battery-operated with a minimum run-time of eight hours. They must have articulating baskets that can tilt and move in various directions, along with OSHA-certified fall arrest systems. The boom lifts must support a minimum of two people and 500 pounds, and have an air line to power tools. They must reach a minimum height of 60 feet and adhere to NEMA requirements for use in wet locations. Bump protection and additional batteries must also be provided to allow for continuous shift operation. The point of contact is Kenneth McCann at the phone number and email provided.
The related federal contract opportunity is a solicitation from the Department of the Air Force Materiel Command Air Force Sustainment Center to procure two 60-foot explosion proof boom lifts as described above.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| JLG-Fall Arrest Platforms.pdf | ||
| Q and A Fall-Arrest System.pdf | ||
| SOW CIP-A60JEX Explosion Proof Boom Lifts - 8-12-22.pdf | ||
| CSS CIP-H3WA15 60ft Exp Proof Boom Lifts.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS AIR FORCE SUSTAINMENT CENTER (AFMC)
TINKER AIR FORCE BASE OKLAHOMA
MEMORANDUM FOR RECORD
SUBJECT: Item Description, H3WA15 60EX Explosion Proof Boom Lifts
1. 76 AMXG request two (2) 60EX Explosion Proof Boom Lifts. The requested descriptions/specifications are outlined below.
• The boom lifts shall be 3rd Party (such as Underwriters Laboratory (UL) and Factory Mutual (FM)) certified for use in a Class I, Division I Hazardous environment
• The boom lifts shall be battery operated
• The batteries shall have a continuous use of a minimum eight (8) hours.
• The boom lifts shall have the capability to articulate in several directions to provide access to difficult to reach areas.
• The basket must be able to tilt and move in various directions.
• The boom lifts shall have OSHA certified fall arrest systems attached to the bucket of the lift that shall allow personnel to safely perform task outside of the basket.
• The contractor shall provide battery chargers for each of the explosion proof boom lifts.
• The boom lifts shall be capable of supporting a minimum of two persons with tools. (Minimum
500 lbs.)
• The boom lifts shall an equipped with a compressed airline to support the operation of tools (paint guns, sanders, HEPA vacuum equipment, etc.).
• The boom lifts shall be capable of reaching a minimum height of 60 feet vertically.
• The boom lifts shall be used in hazardous wet locations and all enclosures shall adhere to NEMA requirements.
• The boom lifts shall have a bump protection system designed to stop movement of the platform if the basket were to come in contact with an object.
• The contractor shall provide an additional battery for each of the explosion proof boom lifts to allow continuous operation of the equipment from shift to shift.
2. Point of contact for this memorandum is Kenneth McCann at (405) 582-4605 or e-mail at kenneth.mccann.1@us.af.mi