This document is a product specification brochure for the GSI AudioStar Pro, a two-channel clinical audiometer being procured by the Virginia School for the Deaf and Blind (VSDB). The equipment is designed for comprehensive hearing assessment across all patient populations and features a user-friendly interface with a single-button, single-function front panel recognized as the industry standard for clinical audiometry. The AudioStar Pro provides true two-channel testing capability with simultaneous testing using different transducers and includes advanced features such as automatic speech functions, pediatric noise options, fine frequency resolution up to 20,000 Hz, and integration with GSI Suite software for comprehensive reporting that combines audiometric, tympanometric, and otoacoustic emissions test results. The procurement requires the vendor to supply the equipment with high-performance speakers, along with mandatory training and installation services at the VSDB facility.
The AudioStar Pro operates across extensive specifications including pure tone testing from 125 to 20,000 Hz for air conduction and 250 to 8,000 Hz for bone conduction, with hearing level ranges from -10 to 120 dB HL for air conduction and customizable masking capabilities. The system is PC-enabled and stand-alone capable, allowing seamless data transfer while maintaining operational continuity during network failures. Technical compliance includes ISO 13485 certification and adherence to ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC 60645-2, and ISO 389 standards, along with medical electrical equipment certifications. Standard accessories include a wireless keyboard and mouse and gooseneck microphone, with power consumption of 90 watts and environmental operational specifications ranging from 59°F to 104°F.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Special_Terms_and_Conditions.docx | DOCX document | |
| Quick Quote Scope of Work.docx | DOCX document | |
| General Terms and Conditions.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TWO CHANNEL
CLINICAL
AUDIOMETER
AUDIOSTAR PRO
THE AUDIOMETER PERFECT FOR EVERY
PATIENT POPULATION
GSI AUDIOSTAR PRO
FAST AND EFFICIENT
The GSI AudioStar Pro™ continues the tradition of excellence in clinical audiometry by maintaining the Grason-Stadler legacy of fast, efficient, and familiar navigation. The one button, one function front panel of the AudioStar Pro is recognized worldwide as the gold standard of user-friendly design, allowing audiologists to test with confidence.
GSI SUITE OFFERS
REPORTING AND COUNSELING
Audiometric results are easily transferred from the AudioStar Pro to GSI Suite software where audiometric, tympanometric, and OAE test results may be combined into a single comprehensive report. Counseling overlays such as the speech banana or hearing loss levels assist the clinician with explaining the results to the patient and family members.
BENEFITS
IMPROVE
EFFICIENCY
True 2 channel testing, including simultaneous testing with different transducers in separate channels, along with independent store buttons, masking level indicators, and fast transitions between test types makes the AudioStar Pro more efficient than ever.
FAMILIAR
NAVIGATION
In order to effectively evaluate every patient, familiarity with audiometry equipment is essential for every clinician. With the recognizable control panel, intuitive display, single button, single function front panel navigation, clinicians will feel an immediate connection with the instrument and be able to quickly and accurately test with confidence.
CUSTOMIZE
PREFERENCES
Personalize facility preferences through the configuration application. Test type buttons, digital word lists (.Wav files), power up preferences, and other options ensure the AudioStar Pro will enhance every facility's testing and reporting needs by adding efficiency and consistency.
3 KEY
FEATURES
AUTOMATIC
SPEECH FUNCTION
Features such as speech auto play, auto advance, and auto frequency selection allow the examiner to improve productivity and patient flow. Configure your digital word lists for reliable recorded speech testing. Eliminate the need to manually calculate SII or PTA.
PEDIATRIC
NOISE
Pediatric audiologists can move quickly between warble, pulsed, and pediatric noise to keep young patients on task.
STAND-ALONE
PC ENABLED
Seamlessly transfer data to a computer. In the event of a network failure or computer lock up, patient data is stored and audiometric testing may continue without interruption.
DIRECT
Expedite the data entry and test administration by using the external keyboard and mouse to enter patient demographics and session comments. Print a complete report directly to a connected printer or USB flash drive.
FINE
FREQUENCY
High resolution frequency testing allows users to perform inter-octave testing with eleven options, from half octave to single frequency.
CUSTOM
CONFIGURATION
Configurable tests and preferences improve workflow and optimize speed of testing. Select preferences such as start up test, auto Hz advance, and wordlist favorites.
KEY
FULL
FREQUENCY
Select the desired frequency range of 8000 - 20,000 or 125 - 20,000 Hz for high frequency audiometry. Access fine frequency resolution such as 1/3 octave bands when performing ototoxic monitoring or tinnitus evaluations.
AUDIOMETRY
PATIENT FOCUSED
PURE
TONE
The Tone Test Type button prepares the AudioStar Pro for pure tone air and bone conduction testing from 125 - 20,000 Hz. Pure tone test settings such as transducer, frequency range, and automatic frequency advance may be customized using the configuration application.
SPEECH
TESTING
The Speech Test Type button enables customized test settings such as wordlist favorites for each test type and automatic scoring preferences. Over 100 integrated wordlists are included for repeatable and reliable recorded speech testing.
QUICK
SPEECH-IN-NOISE
The QuickSIN and BKB-SIN tests are included in the AudioStar Pro. Automatic scoring and calculation of the signal-to-noise ratio loss make it easy to perform speech-in-noise testing on every patient. The BKB-SIN test includes normative data for children as young as five years old.
TECHNICAL
SPECIFICATIONS
DIMENSIONS AND WEIGHT
W x D x H (LCD raised): 20.1 in x 14.6 in x 13.2 in
(51 cm x 37 cm x 33.5 cm) Height (LCD lowered): 5.5 in (14 cm) Weight: 17 lb (7.7 kg) Shipping Weight: 27 lb (12.25 kg)
CHANNELS
Two Independent Channels
PURE TONE – CHANNELS 1 AND 2
FREQUENCY RANGE
Air Conduction: 125 Hz - 20,000 Hz*
Bone Conduction: 250 Hz - 8,000 Hz Sound Field: 125 Hz - 8,000 Hz Paired Inserts: 125 Hz - 8,000 Hz Frequency Accuracy: ±1% Total Harmonic Distortion:
• < 2% (earphones and paired insert phones)
• < 5% (bone vibrator)
HEARING LEVEL RANGE
Air Conduction: -10 dB HL - 120 dB HL Bone Conduction:
| • | Mastoid: -10 dB HL - 90 dB HL |
| • | Forehead: -10 dB HL - 80 dB HL |
Sound Field:
| • | -10 dB HL - 90 dB HL (basic speakers) |
| • | -10 dB HL - 96 dB HL (high performance |
speakers)
• -10 dB HL - 102 dB HL (high performance speakers and external booster amplifier) Paired Inserts: -10 dB HL - 120 dB HL Masking Intensity Range
(Calibrated in effective masking):
• Narrow Band Noise: Maximum dB HL is 15 dB below tone
• White Noise: Maximum dB HL is 30 dB below tone
SIGNAL FORMAT
Steady: Tone continuously present Pulsed: Tone pulsed 200 msec ON, 200 msec OFF FM: Modulation Rate: 5 Hz Modulation Depth: +/- 5% Pulsed/FM: Pulsed and modulated Pediatric Noise Pediatric Noise Pulsed
SPEECH – CHANNELS 1 AND 2
Microphone: For live voice testing and communications INT/EXT A & INT/EXT B: Can be utilized for internal wave files or recorded speech material from an external digital device
INTENSITY RANGE
Air Conduction: -10 dB HL - 100 dB HL Bone Conduction:
• Mastoid: -10 dB HL - 60 dB HL
• Forehead: -10 dB HL - 50 dB HL
Sound Field: -10 dB HL - 90 dB HL Paired Inserts: -10 dB HL - 95 dB HL
MASKING INTENSITY RANGE
Speech Noise:
• Air Conduction: -10 dB HL - 95 dB HL
• Bone Conduction:
-10 dB HL - 50 dB HL (mastoid) -10 dB HL - 40 dB HL (forehead)
• Sound Field: -10 dB HL - 85 dB HL White Noise:
• Air Conduction: -10 dB HL - 95 dB HL
• Bone Conduction:
-10 dB HL - 60 dB HL (mastoid) -10 dB HL - 50 dB HL (forehead)
• Sound Field: -10 dB HL - 80 dB HL
SPECIAL TESTS
ABLB
SISI
High Frequency Audiometry TEN Test QuickSIN
BKB-SIN
Tone Decay AMTAS Pro
SPECIAL TESTS (USER DEFINED)
MLB
Lombard test Pure Tone Stenger Speech Stenger
SAL
Doerfler - Stewart Test
PC ENABLED/STAND-ALONE
Transfer data to connected PC with an E-Record solution software Print complete report directly to a compatible
USB printer
COMMUNICATIONS AND MONITORING
Talk Forward: Permits the tester to speak through the examiner microphone into the selected transducer
Talk Back: Allows the examiner to listen to comments from the patient in the testing booth
Monitor: The monitor headset or monitor speaker built into the instrument housing may be used by the examiner to listen to Channel 1, Channel 2, Aux intercom, and/or Talk Back signals
Aux Intercom: The built-in Auxiliary Intercom and assistant headset allows the examiner to speak directly to an assistant and allows the assistant to hear what is being presented to the patient
On-Board VRA Control: The built-in VRA controls facilitate fast and simple activation of VRA systems
STANDARD ACCESSORIES
Wireless Keyboard and Mouse Gooseneck Microphone
POWER
Power Consumption: 90 Watts Voltage & Amperage: 100-240, 1.0 A max Frequency: 50 Hz and 60 Hz
ENVIRONMENTAL
Temperature: +59° F (15° C) to +104° F (40° C) Storage Temperature: -4° F (-20° C) to +140° F
(60° C) Relative Humidity: 5% to 90% (non-condensing) Ambient Pressure Range: 98 kPa to 104 kPa Background Sound Level: < 35 dB(A) Frequency of Use: Once a year to multiple times per day
QUALITY SYSTEM
Manufactured, designed, developed, and marketed under ISO 13485 certified quality systems
COMPLIANCE
Designed, tested, and manufactured to meet the following domestic (USA), Canadian, European and International Standards:
• ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC 60645-2,
ISO 389
• UL 60601-1 American Standards for Medical
Electrical Equipment
• IEC/EN 60601-1 International Standards for
Medical Electrical Equipment
• CSA C22.2 # 601-1-M90
• Medical Device Directive (MDD) to comply with
93/42/EEC
AUDIOMETER
TWO CHANNEL CLINICAL
1C
-6
DESIGNED SMART. BUILT STRONG.
800-700-2282 l www.grason-stadler.com
*Testing above 8,000 Hz requires HF transducer option