Standard for PBS CAD Deliverables.pdf

PDF 2 MB Posted

Attached to
Co-Gen Project, Phillip Burton FB & USCH Federal contract opportunity
Solicitation number
GS-09P-08-KSC-0040
Issued by
General Services Administration Public Buildings Service Region 9

About this file

GSA CAD Standards

View the file

Other files for this federal contract opportunity

Other files attached to Co-Gen Project, Phillip Burton FB & USCH, newest first.
File Type Posted
Amendment 2.pdf PDF
SGIP reservation instructions.pdf PDF
Reps Certs - ORCA statement.doc DOC document
Amendment 1.pdf PDF
SF 1442 clauses.pdf PDF
Statement of Work.doc DOC document
DB.pdf PDF
Document Security Agreement.doc DOC document
PBS Order 3490.1 - Bldg Doc Security.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table of Contents

1.0 The Basics

1.1 Purpose

1.2 Applicability

1.2.1 Drawing Types

1.2.2 Deviations

1.3 Accuracy

1.4 Ownership

1.5 Dissemination of Sensitive Documents

1.5.1 Sheet File Security Imprint

1.5.2 Cover Sheet Security Imprint

1.6 File Formats

1.6.1 Drawings

1.6.2 Other Formats

1.6.3 Third Party Software

1.7 Additional Infomation

1.7.1 Acronyms

1.7.2 Addresses of Referenced Organizations

2.0 Basic Organizing Concepts for Deliverables

2.1 File Types

2.1.1 Model Files

2.1.2 Sheet Files

2.1.3 Prototype Files

2.2 File Names

2.2.1 Model Files

2.2.2 Model File Designators

2.2.3 Sheet Files

2.2.4 Sheet File Designators

2.2.5 Sheet Type Designators

2.3 Drawing Files

2.3.1 Layer names

2.3.2 Status Field Code

2.3.3 Additional Drawing Requirements

3.0 Tables

3.1 Tables For Creating Drawings

3.1.1 Line Weight

3.1.2 Text Height Guide

3.2 Tables For Plotting Drawings

3.2.1 Plotting Sheet Sizes and Scales

3.3.1 Units and Conversion Guide

3.4.1 Pen Colors

4.0 Deliverable Requirements

4.1 Deliverable Preparation

4.2 Drawing Settings

4.3 Submittal media

4.3.1 CD-ROM Submittal

4.3.2 Labeling of Media

4.4 Project Documentation

5.0 Files for Download

1.0 The Basics

1.1 Purpose

The PBS Standard for CAD Deliverables is for contractors, customers, and associates. It sets mandatory, PBS-wide procedures for Computer Aided Design (CAD) drawings and assignment plans.

Adherence to the Standard allows for the intelligence contained within the drawings to be readily transferred to the data systems used by PBS to conduct its business. Differing regional requirements are accommodated by the addition of Regional Supplements.

These procedures conform to the principles set forth in the National Institute of Building Sciences (NIBS) U.S. National CAD Standard. This standard consists of the American Institute of Architects (AIA) CAD Layer Guidelines, the Construction Specifications Institute (CSI) Uniform Drawing System (UDS), and the Tri-Service and the U.S. Coast Guard Plotting Guidelines.

Drawing templates and information files are available for download at www.gsa.gov/cifm.

1.2 Applicability

These standards are applicable to all PBS drawing types for all PBS facilities in all regions.

There are two major categories of PBS drawings. These are project drawings and facility drawings.

1.2.1 Drawing Types

Project drawings are created for a specific project (whether it be construction or tenant build out) that has a definitive beginning and end. Design intent drawings would fall under the category of project drawings. Once the project is complete, the drawings are updated to reflect as-built conditions and to incorporate amendments and change orders. However, the drawings themselves are a record of past events essentially becoming history. Portions of project drawings may be used to update facility drawings.

Facility drawings reflect the current condition of a building or facility, and by their very nature are living documents that are continually updated. “Intelligent” facility drawings are the primary means of transferring facility data into PBS computer integrated applications such as CAFM and CMMS.

Assignment drawings are a specific type of facility drawing conveying occupancy information. When PBS requests submission of assignment drawings and data, contractors must follow the direction given by the PBS Assignment Drawing Guidance.

1.2.2 Deviations

No deviations are allowed unless approved by the Regional CIFM Manager. The contractor shall submit a Written Deviation Request and maintain a record of all approved deviations and include them with the final submittal. See Section 5.0 Files for Download.

1.3 Accuracy

Contractors are responsible for the accuracy of all CAD drawings delivered to PBS. For all drawing entities all lines meet at intersections, straight lines are straight, and blocks are inserted properly without overlap. PBS may provide contractors with existing CAD drawings for convenience, however, these drawings shall be used as a base reference only. Unless otherwise specified by the contracting documents, the contractor is responsible for field verification of existing conditions, and ensuring that all electronic documents submitted comply with standards.

http://www.gsa.gov/cifm

1.4 Ownership

The Government, for itself and such others as it deems appropriate, will have unlimited rights to all information and materials developed under this contract and furnished to the Government. This includes any documentation thereof, reports and listings, and all other items pertaining to the work and services pursuant to this agreement including any copyright. Unlimited rights under this contract are rights to use, duplicate, or disclose data and information, in whole or in part, in any manner and for any purpose whatsoever without compensations to or approval from the Contractor. The Government will, at all reasonable times, have the right to inspect the work and will have access to and the right to make copies of the above-mentioned items. All digital files, associated data, and other products generated under the contract shall become the property of the Government.

1.5 Dissemination of Sensitive Documents

GSA and the Federal Government are concerned with the safety and security of persons and property under their control. The contractor should ensure that reasonable care is provided to protect sensitive information, both in paper and electronic format, regarding building drawings and specifications for design, construction and/or renovation, security equipment and installation, and contract guard information related to GSA-controlled facilities from being used for illegal purposes.

1.5.1 Sheet File Security Imprint

All building plans, drawings, and specifications prepared for construction or renovation, and/or security services, either in electronic or paper formats, shall have included on each sheet file of the construction drawings or plans in a minimum of 14 point bold face type (3 mm or about 1/8”):

PROPERTY OF UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

1.5.2 Cover Sheet Security Imprint

The following paragraph will be noted on the cover page of all drawing sets and on the cover page of the specifications in a minimum of 14 point bold face type (3 mm or about 1/8”):

PROPERTY OF THE UNITED STATES GOVERNMENT

COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS,

OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED

Do not remove this notice

Properly destroy documents when no longer needed

1.6 File Formats

1.6.1 Drawings

All drawings shall be readable by the AutoCAD version specified by each region, and shall be *.DWG files. Being “readable” is constituted by the ability to open a file without any errors, such as proxy, font substitution, xref resolution, etc., and the objects, layers, etc. in the file remaining intact. AEC software using object technology must comply with the Standard for PBS CAD Deliverables.

The contractor shall be responsible for software and data upgrades throughout the contract lifecycle.

The contractor will consult with the Regional CIFM Program Manager to confirm software versions prior to all submissions.

1.6.2 Other Formats

Word Processor documents shall be Microsoft Word files. Macros may be included with these documents provided they are virus free, their function is explained next to the code, and are not write-protected.

Spreadsheet documents shall be Microsoft Excel files.

Graphics may be submitted in *.TIF, *.GIF, *.JPG, *.CALS, *.PDF or *.BMP file format only. This option is intended for photos, conceptual sketches, etc., and not as an indication that raster file drawings will be accepted in lieu of AutoCAD files.

When a hard copy drawing in the drawing set includes photographs or other images the electronic file submission shall include a corresponding AutoCAD *.DWG sheet file containing these raster images as xrefs or embedded files.

Project Management Schedule documents shall be Microsoft Project files or P3 Primavera files as specified by each region. Project files shall be saved with a baseline.

Deliverables integrating multiple file formats may be sumitted in *.PDF file format (to maintain formatting) in addition to the base file structure. Examples include reports, photographs, and manuals created by using a variety of software packages and file formats.

1.6.3 Third Party Software

A written request must be submitted to GSA and permission granted in order to submit electronic data in a format other than those specifically named above. This includes AutoCAD add-on applications that leave non-native objects in drawings and AutoCAD-integrated applications, such as Architectural Desktop. When it is considered in the best interest of the Government, the Contracting Officer may permit third party software. Any third party software used that modifies or creates layers in AutoCAD shall adhere to the AIA CAD Layering Guidelines.

1.7 Additional Infomation

1.7.1 Acronyms

A/E Architectural/Engineering AEC Architects, Engineers, Contractors AIA American Institute of Architects ANSI American National Standards Institute BOMA Building Owners and Managers Association CAD Computer Aided Design CAFM Computer Aided Facility Management CIFM Computer Integrated Facility Management CMM Computerized Maintenance Management CSI Construction Specifications Institute DWG File extension for AutoCAD drawings DWT File extension for AutoCAD template drawings FM Facility Management GSA General Services Administration IAI International Alliance for Interoperability NCS U.S. National CAD Standard NIBS National Institute of Building Standards PBS Public Building Service UDS Uniform Drawing System Xref Externally referenced

1.7.2 Addresses of Referenced Organizations

American Institute of Architects (AIA) (CAD Layer Guidelines, Architectural Graphic Standards) Info Central (800) AIA-3837 Internet http://www.aia.org

The Construction Specifications Institute (CSI) (Uniform Drawing System) Voice (800) 689-2900 Internet http://www.csinet.org

American National Standards Institute (ANSI) Voice (212) 642-4900 Internet http://www.ansi.org

International Alliance for Interoperability (IAI) (Object Technology) Internet http://iaiweb.lbl.gov

Building Owners and Managers Association (BOMA) Voice (202) 408-2662 Internet http://www.boma.org

National Institute of Building Sciences (NIBS) (Metric Guide for Federal Construction, U.S. National CAD Standard) Internet http://www.nibs.org

The CADD/GIS Technology Center for Facilities, Infrastructure, and Environment (Symbols, Tri-Service Plotting Guidelines) U.S. Army Engineer Research and Development Center Internet http://tsc.wes.army.mil

U.S. Coast Guard Civil Engineering Technology Center

(CETC)

(Tri-Servicel Plotting Guidelines) Voice (216) 902-6209 Internet http://www.uscg.mil/mlclant/cetc/ http://www.aia.org/ http://www.csinet.org/ http://www.ansi.org/ http://iaiweb.lbl.gov/ http://www.boma.org/ http://www.nibs.org/ http://tsc.wes.army.mil/ http://www.uscg.mil/mlclant/cetc/

2.0 Basic Organizing Concepts for Deliverables

2.1 File Types

PBS requires two types of CAD deliverable files: model and sheet files. PBS also provides prototype files.

2.1.1 Model Files

Model files represent the building’s physical layout and components such as floor plans, elevations, details, schematic diagrams, etc. each requiring its own separate model file. Model files are drawn full size in model space with the exception of schematic diagrams, which can be at any scale. While most buildings are depicted by a series of 2D models, model files may contain 3D information.

Model files include an attribute block, provided by PBS, that describes the content of the model file.

The attribute block is inserted on layer G-ANNO-TTLB at 0,0,0 in paper space.

2.1.2 Sheet Files

Sheet files are used to assemble model files for plotting and viewing purposes. Every sheet file has a drawing area, title block, and border and represents one plotted drawing. Sheet files shall be assembled in paper space, and set up to be plotted at 1” = 1” scale (plotscale=1). In AutoCAD, separate layout tabs may be used for plotting different sizes of the same drawing within the same sheet file.

The typical multiple file approach using model and sheet files is illustrated below.

Model files are externally referenced into the sheet file’s model space. For the purposes of consistency and minimizing data entry PBS has developed a title block template. Use of the provided title block (see section 5.0) is required unless indicated by the Regional Supplements.

2.1.3 Prototype Files

PBS provides various prototypes for contractor use. See Section 5.0 Files for Download.

Drawing Assembly Diagram

The base model file is externally referenced into the discipline specific model file (if applicable) at full size in model space. The discipline specific model file is externally referenced into the sheet file at full size in model space. Viewport(s) are drawn in paper space. The drawing content is scaled through the viewport(s) and plotted at 1:1.

2.2 File Names

The U.S. National CAD Standard Version 2.0 allows the use of a hyphen or underscore as a place holder in file names, PBS allows only an underscore to facilitate data transfer to other PBS systems.

2.2.1 Model Files

Model file names consist of a discipline designator and underscore, followed by a two-letter model file type, followed by a two-character floor number. Use of a two-character user definable field is optional. An example of a model file name, A_FP01 is the first floor architectural plan.

Detail file names consist of a discipline designator, followed by a two-letter model file type, followed by a three-character user definable field. A_DTSIL is the sill detail in the architectural plan.

Model file type User Defined

A

Model file type

_ F P 0 1

User definable

Discipline designator

Floor number

Discipline designator

LI ST D _ A

2.2.2 Model File Designators

Model file type (apply to all disciplines) Discipline designator (two-character field with second character as an underscore) *_FP Floor plan *_EL Elevation *_DP Demolition plan *_SC Section A Architectural *_SP Site plan *_DT Detail B Geotechnical *_QP Equipment plan *_SH Schedule C Civil *_XP Existing plan *_3D Isometric/3D D Process *_RO Roof plan *_DG Diagrams E Electrical F Fire protection Model file type (discipline specific) G General Civil Fire protection H Hazardous materials C_EP Environmental plan F_KP Sprinkler system I Interiors C_GP Grading plan *_VP Evacuation plan L Landscape C_RP Road/topographic plan M Mechanical C_SV Survey O Operations (includes facility and C_UP Utility plan assignment drawing) P Plumbing Structural Plumbing Q Equipment S_FP Framing plan P_PP Plumbing plan R Resource S_NP Foundation plan S Structural T Telecommunications Architectural Mechanical V Survey/mapping A_EP Enlarged plan M_CP Control plan W Civil work A_CP Ceiling plan M_HP HVAC ductwork X Other disciplines A_RP Furniture plans M_PP Piping plan Z Contractor/shop drawing A_NP Finish plans

Floor number Interiors Electrical 01-99 First to 99th floor I_EP Enlarged plans E_LP Lighting B1 Basement I_CP Ceiling plans E_PP Power G1 Ground Floor I_RP Furniture plans E_GP Grounding K1 Parking I_NP Finish plans E_CP Communications M1 Mezzanine P1 Penthouse CAFM (assignment plan only) Telecommunications RX Roof Plan A through Z O_KY Key drawing T_TP Telecommunications SB Sub_Basement O_SR Source drawing

Note 1: if more than one, use increment number on mezzanines, penthouses, parking, and basements.

Note 2: floor number may not apply to all drawings, especially details.

2.2.3 Sheet Files

Sheet file names consist of the discipline designator, either a single character with underscore (Level

1) or two character (Level 2); followed by the sheet type designator, followed by the sheet sequence number; usually a two-character field starting at 01 and continuing through 99. Use of a three-character user definable field is optional.

Sheet sequence number User definable

Sheet type designator Discipline designator Level 1

1 0 1 _ A

Within the two character discipline designator, the first character is the discipline character and the second is the modifier. The modifier is used to subdivide the information for a specific use or purpose, such as project complexity, or need for specialization in intricate fields. For example AD101 would be the first architectural demolition plan in the set.

Sheet sequence number User definable

Sheet type designator Discipline designator Level 2

1 0 1 D A

2.2.4 Sheet File Designators

Level 1 Level 2 Description of Suggested Name Content A Architectural All or any portion of subjects included in Level 2 AS Architectural Site AD Architectural Demolition Protection and removal AE Architectural Elements General Architectural AI Architectural Interiors AF Architectural Finishes AG Architectural Graphics AJ User Defined AK User Defined C Civil All or any portion of subjects included in Level 2 CD Civil Demolition Structure removal and site clearing CS Civil Site Plats, dimension control CG Civil Grading Excavation, grading, drainage, erosion control CP Civil Paving Roads, driveways, parking lots CI Civil Improvements Pavers, flagstone, exterior tile, furnishings, retaining walls, and water features CT Civil Transportation Waterways, wharves, docks, trams, railways, people movers CU Civil Utilities Water, sanitary sewer, storm sewer, power, communications, fiber optic, telephone, cable television, natural gas, and steam systems

CJ User Defined CK User Defined W Civil Works All or any portion of subjects included in Level 2 WJ User Defined WK User Defined Z Contractor/Shop Drawings All or any portion of subjects included in Level 2 ZJ User Defined ZK User Defined E Electrical All or any portion of subjects included in Level 2 ES Electrical Site Utility tunnels, site lighting ED Electrical Demolition Protection, termination, and removal EP Electrical Power EL Electrical Lighting EI Electrical Instrumentation Controls, relays, instrumentation, and measurement devices ET Electrical Telecommunications Telephone, network, voice and data cables EY Electrical Auxiliary Systems Alarms, nurse call, security, CCTV. PA, music, clock, and program EJ User Defined EK User Defined Q Equipment All or any portion of subjects included in Level 2 QA Athletic Equipment Gymnasium, exercise, aquatic, and recreational QB Bank Equipment Vaults, teller units, ATMs, drive-through QC Dry Cleaning Equipment Washers, dryers, ironing, and dry cleaning QD Detention Equipment Prisons and jails QE Education Equipment Chalkboards, library QF Food Service Equipment Kitchen, bar, service, storage, and processing QH Hospital Equipment Medical, exam, and treatment QL Laboratory Equipment Science labs, planetariums, observatories QM Maintenance Equipment Housekeeping, window washing, and vehicle servicing QP Parking Lot Equipment Gates, ticket and card access QR Retail Equipment Display, vending, and cash register QS Site Equipment Bicycle racks, benches, playgrounds QT Theatrical Equipment Stage, movie, rigging systems QV Video/Photographic Equipment Television, darkroom, and studio QY Security Equipment Access control and monitoring, surveillance QJ User Defined QK User Defined

F Fire Protection All or any portion of subjects included in Level 2 FA Fire Detection and Alarm FX Fire Suppression Fire extinguishing systems and equipment FJ User Defined FK User Defined G General All or any portion of subjects included in Level 2 GI General Information Drawing index, code summary, symbol legend, orientation maps GC General Contract Phasing, schedules, contractor staging areas, fencing, haul routes, erosion control, temporary and special requirements

GR General Resource Photographs, soil borings GJ User Defined GK User Defined B Geotechnical All or any portion of subjects included in Level 2 BJ User Defined BK User Defined H Hazardous Materials All or any portion of subjects included in Level 2 HA Asbestos Asbestos abatement, identification or containment HC Chemicals Toxic chemicals handling, removal or storage HL Lead Lead piping or paint removal HP PCB PCB containment and removal HR Refrigerants Ozone depleting refrigerants HJ User Defined HK User Defined I Interiors All or any portion of subjects included in Level 2 ID Interior Demolition IN Interior Design IF Interior Furnishings IG Interior Graphics Murals and visuals IJ User Defined IK User Defined L Landscape All or any portion of subjects included in Level 2 LD Landscape Demolition Protection and removal of existing landscaping LI Landscape Irrigation LP Landscape Planting LJ User Defined LK User Defined M Mechanical All or any portion of subjects included in Level 2 MS Mechanical Site Utility tunnels and piping between facilities MD Mechanical Demolition Protection, termination, and removal MH Mechanical HVAC Ductwork, air devices, and equipment MP Mechanical Piping Chilled and heating water, steam MI Mechanical Instrumentation Instrumentation and controls MJ User Defined MK User Defined O Operations All or any portion of subjects included in Level 2 OJ User Defined OK User Defined X Other Disciplines All or any portion of subjects included in Level 2 XJ User Defined XK User Defined P Plumbing All or any portion of subjects included in Level 2 PS Plumbing Site Extension and connections to Civil Utilities PD Plumbing Demolition Protection, termination, and removal PP Plumbing Piping Piping, valves and insulation PQ Plumbing Equipment Pumps and tanks PL Plumbing Domestic water, sanitary and storm drainage, fixtures PJ User Defined PK User Defined

D Process All or any portion of subjects included in Level 2 DS Process Site Extension and connection to civil utilities DD Process Demolition Protection, termination and removal DL Process Liquids Liquid process systems DG Process Gases Gaseous process systems DP Process Piping Piping, valves, insulation, tanks, pumps, etc.

DQ Process Equipment Systems and equipment for thermal, electrical, materials handling, assembly and manufacturing, nuclear, power generation, chemical, refrigeration, and industrial processes

DE Process Electrical Electrical exclusively associated with a process and not the facility

DI Process Instrumentation Instrumentation, measurement, recorders, devices and controllers (electrical and mechanical)

DJ User Defined DK User Defined R Resource Data furnished without warrant as to accuracy RC Resource Civil Surveyor’s information and existing civil drawings RS Resource Structural Existing facility structural drawings RA Resource Architectural Existing facility architectural drawings RE Resource Electrical Existing facility electrical drawings RJ User Defined RK User Defined S Structural All or any portion of subjects included in Level 2 SD Structural Demolition Protection and removal SS Structural Site SB Structural Substructure Foundations, piers, slabs, and retaining walls SF Structural Framing Floors and roofs SJ User Defined SK User Defined

V Survey Mapping All or any portion of subjects included in Level 2 VA Aerial VF Field VI Digital VU Combined Utilities VJ User Defined VK User Defined T Telecommunications All or any portion of subjects included in Level 2 TA Audio Visual Cable, music, and CCT systems TC Clock and Program Time generators and bell program systems TI Intercom Intercom and public address systems TM Monitoring Monitoring and alarm systems TN Data Networks Network cabling and equipment TT Telephone Telephone systems, wiring, and equipment TY Security Access control and alarm systems TJ User Defined TK User Defined

2.2.5 Sheet Type Designators

Sheet type designator (one number field) 0 General (symbols, legends, notes, etc.)

1 Plans (horizontal views) 2 Elevations (vertical views) 3 Sections (sectional views) 4 Large scale (plans, elevations, or sections that are not details) 5 Details 6 Schedules and diagrams 7 User defined 8 User defined 9 3D Views (isometric, perspectives, photographs)

2.3 Drawing Files

2.3.1 Layer names

PBS has adopted AIA layer naming conventions. The AIA CAD Layer Guidelines, U.S. National CAD Standard Version 2.0 contains the AIA master layer list that contractors must follow. To order hard copies, refer to 1.7.2 Addresses of Referenced Organizations. PBS has developed electronic templates with the most common layers for each discipline (see Section 5.0 Files for Download).

These templates are available at www.gsa.gov/cifm.

Layer names consist of the discipline designator, followed by the major group designator indicating the building system, followed by an optional single character status designator. A four-character minor group designator may be added to further define the major group. For clarity there may be multiple minor group fields. For example, A-WALL-FULL-E would be the layer full height architectural wall existing to remain.

Discipline designator

Major group Minor group

Status

E - LLUF- LLA W - A

The AIA master layer list allows different layer names for the same information such as A-COLS, I- COLS, and S-COLS. PBS does not allow the use of duplicate names preferring that the information be placed on the layer of the discipline responsible for the information. For example, columns should always be placed on the structural layer (S-COLS), lighting should always be placed on the electrical layer (E-LITE), and plumbing fixtures should always be placed on the plumbing layer (P-FIXT).

Additional layers may be may be required for specified projects.

2.3.2 Status Field Code

N New work E Existing to remain D Existing to demolish T Temporary work M Items to be moved R Relocated items V Survey Mapping X Not in contract 1-9 Phase numbers

2.3.3 Additional Drawing Requirements

Attributes. Attributes may be used to store data in the drawing. Do not use attributes to store large amounts of data (greater than 10% of drawing size) or types of data that are better stored in external databases. PBS requires the use of an attributed title block and a model file attributed block to store descriptive data about the drawings, see title blocks.

Blocks. Any graphic entity that occurs repeatedly in drawings should be made into a block. Attributes contained within a block should pertain to the current project. Insertion points for each block shall be consistent with its placement in the drawing. Use logical insertion points such as the center of a circle, bottom left corner of an object, etc. Keep names simple and descriptive. Purge all unused blocks from the drawing. Nested blocks are permitted but should be avoided whenever possible. If nested blocks are used, they must be documented on the Project and Drawing Documentation form (see Section 3 Deliverable Requirements). Draw objects used to create blocks on layer 0 so the block inherits the properties of the layer on which it is inserted. Do not insert blocks on layer 0 (zero).

When submitting drawings no objects will be on layer 0 (zero) unless otherwise specified.

Color and pen assignments. AutoCAD R14 or earlier versions use layer colors to control pen assignments, which correspond to line width in plotted drawings. For AutoCAD R2000 entity line weights shall be assigned by layer. Supplemental requirements may specify line weights for particular layers. Select layer colors in accordance with the Pen Table in Section 3.4.1.

Dimensioning. All dimensions shall update automatically when the distance they are measuring changes. Metric dimensions shall conform to Metric Design Guide or M2: Metric Design Guide, Third Edition. General information on metrification can be found in the Metric Guide for Federal Construction. All three publications are available through NIBS.

Drawing limits. Do not set the limits any larger than necessary to accommodate the drawing. No entities shall be located outside the drawing limits.

Drawing origin. Organize drawings in model space so that the lower left intersection of the outermost column lines that remain constant on most floors is placed at 0,0,0. In order to ensure proper insertion of xrefs and the stacking of floor plans, the origin point for an entire building must be consistent between model files. Once the origin is established, it cannot be changed. For sheet files, place the lower left corner of the sheet at 0,0,0.

Graphic standards. Drawing standards and symbology shall be in accordance with the AIA Architectural Graphic Standards. The U.S. National CAD Standard is also a good reference for drawing symbols, details, and guidelines.

Hatching. Do not use polylines with increased width for poché or hatching. All hatching shall be associative.

Key Plan. G-PLAN is the layer on which the key site plan should be drawn.

Layers. Follow the AIA CAD Layer Guidelines, U.S. National CAD Standard Version 2.0.

Layer colors. The Layer Color used in AutoCAD R14 and earlier versions controlled pen assignments and line width in plot files. In AutoCAD 2000 line weights shall be assigned by layer. Entities shall conform to control by Layer.

Linetypes. Contour lines, dashed lines, and other fonted lines shall be made of one continuous line segment, not a series of separate line segments. If linetypes other than standard AutoCAD linetypes are used the *.LIN file must be provided with the submission. Section 5.0 Files for Download includes a *.LIN file for use. Use of toned or pochéd lines are acceptable for distinguishing between various types of work, such as new from existing, phase 1 from phase 2, or background floor plans.

Curved entities such as circles, arcs, and ellipses shall be created of one continuous line segment, the exception being entities that have to be physically constructed in a segmented fashion. These may be segmented to represent the joints in the actual construction.

Lineweights. To assign lineweights in AutoCAD 2000 and later, assign lineweights to layers. In the layer properties dialog box, select the lineweight of a layer, then select the lineweight to be used for all entities on that layer.

Scale. Create drawing entities at full size. For example, a 100-foot wall will be drawn to 100 feet and a 36-inch column will be drawn to 36 inches. Drawings considered schematic in nature can be drawn to any scale. Some examples of schematic drawings are schedules, riser diagrams, schematic diagrams, and single line diagrams.

Plan drawings. Create a separate model file for each drawing. Use sheet files to combine floor plans with non-plan information or multiple elevations. Do not combine several drawings such as elevations, sections, and details in one model file. When a floor plan is too large to fit on a single sheet at the desired scale use viewports in separate sheet files to show portions of the floor. DO NOT create individual model files for portions of a floor. For sheet sizes see Section 3.2.1.

Title Blocks. PBS requires the use of a standardized, attributed title block for each sheet file. PBS also requires a standardized, attributed block in all model files. Templates, blocks, and instructions are listed in Section 5.0 Files for Download and are available at www.gsa.gov/cifm.

Text and fonts. Use only standard AutoCAD or approved True Type fonts. The text syles.doc contains a list of acceptable fonts. The minimum plotted text size for all full size drawings shall be 3/32”. For clarity and presentation purposes it may be necessary to use other text sizes.

Units. Metric units shall be the standard system of measurement for new facilities unless otherwise specified. Imperial units may be used for projects in existing buildings when existing drawings are Imperial. Project scope of work will specify use of Imperial or metric units. Base units for metric shall be millimeters; for imperial use inches.

Xrefs. AutoCAD term for external reference. Xrefs help to organize drawing information, enhance coordination, and minimize redundant data. The xref path shall not include drives or directory designations and the xref is placed on layer G-ANNO-REFR. Document the relationship between drawing file and xref on the project documentation report and deliverables matrix. See Section 4.4 Project Documentation.

3.0 Tables

The following tables are provided for reference purposes. They are intended to aid CAD drafters in the creation of drawings by providing standard data for text sizing, scale, and plotting.

3.1 Tables For Creating Drawings

3.1.1 Line Weight

Line weights are used to improve drawing readability. The table below shows some typical weights and their uses in construction drawings.

Line weight

Line weight

Layer name*

Description

Thin 0.18 mm/

0.007 in.

THIN Dimension leaders/ witness lines, dimension lines, object lines seen in the distance, and most patterns.

Medium 0.25 mm/

0.010 in.

MEDM Minor object lines, line terminators (arrowheads and ticks), hidden lines, and note leader lines.

Medium thick 0.35 mm/

0.014 in.

MEDT Most object lines, text, schedule boxes, and charts.

Thick 0.50 mm/

0.020 in.

THIK Minor title underlining, title text, object lines requiring special emphasis.

Extra thick 0.70 mm/

0.028 in.

XTHK Use sparingly for underlining titles and separating portions of drawings, elevation grade lines, building footprints, and top of grade markings.

Optional 1.00 mm/

0.040 in.

OPTI

* Layer name modifier to use when layers are separated by line weights such as title blocks and details.

3.1.2 Text Height Guide

Standardized text height in drawings allows for consistent presentation and plotting. The tables below list standard plotted text heights and the corresponding drawing height for each scale.

Metric

Plotted Text Height Metric scale 2mm 3mm 5mm 6mm 12mm 24mm 1:200 Text Height = 400mm 600mm 1000mm 1200mm 2400mm 4800mm 1:100 Text Height = 200mm 300mm 500mm 600mm 1200mm 2400mm 1:50 Text Height = 100mm 150mm 250mm 300mm 600mm 1200mm 1:25 Text Height = 50mm 75mm 125mm 150mm 300mm 600mm 1:10 Text Height = 20mm 30mm 50mm 60mm 120mm 240mm 1:5 Text Height = 10mm 15mm 25mm 30mm 60mm 120mm 1:1 Text Height = 2mm 3mm 5mm 6mm 12mm 24mm Actual height of text in CAD drawing

Imperial

Plotted Text Height

3/32” 1/8” 5/32” 3/16” ¼” 3/8” ½” 3’ 4’ 5’ 6’ 8’ 12’ 16’ 1’-6” 2’ 2’-6” 3’ 4’ 6’ 8’ 1’-1.5” 1’-6” 1’-8” 2’-3” 3’ 4’-6” 6’ 9” 1’ 1’-3” 1’-6” 2’ 3’ 4’ 4.5” 6” 7.5” 9” 1’ 1’-6” 2’ 3” 4” 5” 6” 8” 1’ 1’-4” 2.25” 3” 3.75” 4.5” 6” 9” 1’ 1.5” 2” 2.5” 3” 4” 6” 8” 1.13” 1.5” 1.875” 2.25” 3” 4.5” 6” .75” 1” 1.25” 1.5” 2” 3” 4”

Imperial scale 1/32”=1’-0” Text Height = 1/16”=1’-0” Text Height = 3/32”=1’-0” Text Height = 1/8”=1’-0” Text Height = ¼”=1’-0” Text Height = 3/8”=1’-0” Text Height = ½”=1’-0” Text Height = ¾”=1’-0” Text Height = 1”=1’-0” Text Height = 1 ½”=1’-0” Text Height = 3”=1’-0” Text Height = .38” .5” 0.625’ .75” 1” 1.5” 2” Actual height of text in CAD drawing

3.2 Tables For Plotting Drawings

3.2.1 Plotting Sheet Sizes and Scales

Sheet Sizes (ANSI sizes A, B, and Architectural sizes)

Size Horizontal dimension Vertical dimension F 1,067 mm (42”) 762 mm (30”) E 1,219 mm (48”) 914 mm (36”) D 914 mm (36”) 610 mm (24”) C 610 mm (24”) 457 mm (18”) ANSI B 432 mm (17”) 279 mm (11”) ANSI A 279 mm (11”) 216 mm ( 8½”)

Acceptable Scales For reference only for plotting model files. Full size sheet files shall be assembled in paper space and plotted at 1:1.

Architectural scales Engineering scales Metric scales Drawing scale Plot scale Drawing scale Plot scale Drawing scale Plot scale 1” = 5000’ 60000 1” = 2500’ 30000 1” = 1250’ 15000 1” = 1000’ 12000 1” = 500’ 6000 1:5000 5000 1” = 200’ 2400 1:2500 2500 1” = 100’ 1200 1:1250 1250 1” = 50’ 600 1:1000 1000 1” = 40’ 480 1:500 500 1” = 30’ 360 1/16” = 1’-0” 192 1” = 20’ 240 1:200 200 1/8” = 1’-0” 96 1” = 10’ 120 1:100 100 ¼” = 1’-0” 48 1” = 5’ 60 1:50 50 3/8” = 1’-0” 32 1:30 30 ½” = 1’-0” 24 1” = 2’ 24 1:20 20 ¾” = 1’-0” 16 1” = 2’ 24 1:20 20 1” = 1’-0” 12 1” = 1’ 12 1:10 10 1 ½” = 1’-0” 8 1:10 10 3” = 1’-0” 4 1:5 5 6” = 1’-0” 2 1:2 2 Full size 1 1:1 1

3.3.1 Units and Conversion Guide

Comparison of Drawing Scales

Inch-foot scales Inch-foot ratio Metric scale Full Size 1:1 1:1 Half Size 1:2 1:2 4” = 1’-0” 1:3 3” = 1’-0” 1:4 1:5 2” = 1’-0” 1:6 1-1/2” = 1’-0” 1:8 1:10 1” = 1’-0” 1:12 ¾” = 1’-0” 1:16 1:20 ½” = 1’-0” 1:24 1:25 ¼” = 1’-0” 1:48 1:50 1” = 5’-0” 1:60 1/8” = 1’-0” 1:96 1:100 1” = 10’-0” 1:120 1/16” = 1’-0” 1:192 1:200 1” = 20’-0” 1:240 1:250 1” = 30’-0” 1:360 1/32” = 1’-0” 1:384 1” = 40’-0” 1:480 1:500 1” = 50’-0” 1:600 1” = 60’-0” 1:720 1” = 80’-0” 1:960 1:1000

Conversion Factors

Quantity From inch-pound units To metric units Multiply by Length mile km 1.609 344* yard m 0.914 4* foot m 0.304 8* mm 304.8* inch mm 25.4* Area square mile km2 2.590 00 acre m2 4 046.87 ha (10 000m2) 0.404 687 square yard m2 0.836 127 36* square foot m2 0.092 903 04* square inch mm2 645.16*

*Denotes the exact conversion

3.4.1 Pen Colors

The consistent presentation and plotting of all CAD drawings is extremely important in PBS. The following table specifies plotting/printing line weight settings for AutoCAD colors. All construction drawings shall use the settings outlined below.

AutoCAD color no.

Pen plotter pen (mm)

Laser/ink-jet (in.)

Plot color AutoCAD Color No.

Pen plotter pen (mm)

Laser/ink-jet (in.)

Plot color

1 0.18 0.007 Black 57 0.70 0.028 Halftone 2 0.25 0.010 Black 58 0.35 0.014 Halftone 3 0.35 0.014 Black 59 1.00 0.040 Black 4 0.35 0.014 Black 60 0.18 0.007 Olive 5 0.50 0.020 Black 61 0.25 0.010 Olive 6 0.70 0.028 Black 62 0.35 0.014 Olive 7 0.25 0.010 Black 63 0.50 0.020 Olive 8 0.35 0.014 Halftone 64 0.70 0.028 Olive 9 1.00 0.040 Black 65 1.00 0.040 Olive 10 0.25 0.010 Black 66 0.70 0.028 Olive 11 0.35 0.014 Black 67 0.70 0.028 Olive 12 0.50 0.020 Black 68 0.35 0.014 Olive 13 0.70 0.028 Black 69 1.00 0.040 Olive 14 1.00 0.040 Black 70 0.18 0.007 Black 15 0.50 0.020 Black 71 0.25 0.010 Black 16 0.70 0.028 Black 72 0.35 0.014 Black 17 0.70 0.028 Halftone 73 0.50 0.020 Black 18 0.35 0.014 Halftone 74 0.70 0.028 Black 19 1.00 0.040 Black 75 1.00 0.040 Black 20 0.18 0.007 Rust 76 0.70 0.028 Black 21 0.25 0.010 Rust 77 0.70 0.028 Halftone 22 0.35 0.014 Rust 78 0.35 0.014 Halftone 23 0.50 0.020 Rust 79 1.00 0.040 Black 24 0.70 0.028 Rust 80 0.18 0.007 Green 25 1.00 0.040 Rust 81 0.25 0.010 Green 26 0.70 0.028 Rust 82 0.35 0.014 Green 27 0.70 0.028 Rust 83 0.50 0.020 Green 28 0.35 0.014 Rust 84 0.70 0.028 Green 29 1.00 0.040 Rust 85 1.00 0.040 Green 30 0.18 0.007 Black 86 0.70 0.028 Green 31 0.25 0.010 Black 87 0.70 0.028 32 0.35 0.014 Black 88 0.35 0.014 Green 33 0.50 0.020 Black 89 1.00 0.040 Green 34 0.70 0.028 Black 90 0.18 0.007 Black 35 1.00 0.040 Black 91 0.25 0.010 Black 36 0.70 0.028 Black 92 0.35 0.014 Black 37 0.70 0.028 Halftone 93 0.50 0.020 Black 38 0.35 0.014 Halftone 94 0.70 0.028 Black 39 1.00 0.040 Black 95 1.00 0.040 Black 40 0.18 0.007 Gold 96 0.70 0.028 Black 41 0.25 0.010 Gold 97 0.70 0.028 Halftone 42 0.35 0.014 Gold 98 0.35 0.014 Halftone 43 0.50 0.020 Gold 99 1.00 0.040 Black 44 0.70 0.028 Gold 100 0.18 0.007 Forest 45 1.00 0.040 Gold 101 0.25 0.010 Forest 46 0.70 0.028 Gold 102 0.35 0.014 Forest 47 0.70 0.028 Gold 103 0.50 0.020 Forest 48 0.35 0.014 Gold 104 0.70 0.028 Forest 49 1.00 0.040 Gold 105 1.00 0.040 Forest 50 0.18 0.007 Black 106 0.70 0.028 Forest 51 0.25 0.010 Black 107 0.70 0.028 Forest 52 0.35 0.014 Black 108 0.35 0.014 Forest 53 0.50 0.020 Black 109 1.00 0.040 Forest 54 0.70 0.028 Black 110 0.18 0.007 Black 55 1.00 0.040 Black 111 0.25 0.010 Black 56 0.70 0.028 Black 112 0.35 0.014 Black

Green

Pen plotter pen (mm)

Laser/ink-jet (in.)

Plot color AutoCAD Color No.

Pen plotter pen (mm)

Laser/ink-jet (in.)

Plot color

113 0.50 0.020 Black 180 0.18 0.007 Navy 114 0.70 0.028 Black 181 0.25 0.010 Navy 115 1.00 0.040 Black 182 0.35 0.014 Navy 116 0.70 0.028 Black 183 0.50 0.020 Navy 117 0.70 0.028 Halftone 184 0.70 0.028 Navy 118 0.35 0.014 Halftone 185 1.00 0.040 Navy 119 1.00 0.040 Black 186 0.70 0.028 Navy 120 0.18 0.007 Teal 187 0.70 0.028 Navy 121 0.25 0.010 Teal 188 0.35 0.014 Navy 122 0.35 0.014 Teal 189 1.00 0.040 Navy 123 0.50 0.020 Teal 190 0.18 0.007 Black 124 0.70 0.028 Teal 191 0.25 0.010 Black 125 1.00 0.040 Teal 192 0.35 0.014 Black 126 0.70 0.028 Teal 193 0.50 0.020 Black 127 0.70 0.028 Teal 194 0.70 0.028 Black 128 0.35 0.014 Teal 195 1.00 0.040 Black 129 1.00 0.040 Teal 196 0.70 0.028 Black 130 0.18 0.007 Black 197 0.70 0.028 Halftone 131 0.25 0.010 Black 198 0.35 0.014 Halftone 132 0.35 0.014 Black 199 1.00 0.040 Black 133 0.50 0.020 Black 200 0.18 0.007 Purple 134 0.70 0.028 Black 201 0.25 0.010 Purple 135 1.00 0.040 Black 202 0.35 0.014 Purple 136 0.70 0.028 Black 203 0.50 0.020 Purple 137 0.70 0.028 Halftone 204 0.70 0.028 Purple 138 0.35 0.014 Halftone 205 1.00 0.040 Purple 139 1.00 0.040 Black 206 0.70 0.028 Purple 140 0.18 0.007 Cyan 207 0.70 0.028 Purple 141 0.25 0.010 Cyan 208 0.35 0.014 Purple 142 0.35 0.014 Cyan 209 1.00 0.040 Purple 143 0.50 0.020 Cyan 210 0.18 0.007 Black 144 0.70 0.028 Cyan 211 0.25 0.010 Black 145 1.00 0.040 Cyan 212 0.35 0.014 Black 146 0.70 0.028 Cyan 213 0.50 0.020 Black 147 0.70 0.028 Cyan 214 0.70 0.028 Black 148 0.35 0.014 Cyan 215 1.00 0.040 Black 149 1.00 0.040 Cyan 216 0.70 0.028 Black 150 0.18 0.007 Black 217 0.70 0.028 Halftone 151 0.25 0.010 Black 218 0.35 0.014 Halftone 152 0.35 0.014 Black 219 1.00 0.040 Black 153 0.50 0.020 Black 220 0.18 0.007 Magenta 154 0.70 0.028 Black 221 0.25 0.010 Magenta 155 1.00 0.040 Black 222 0.35 0.014 Magenta 156 0.70 0.028 Black 223 0.50 0.020 Magenta 157 0.70 0.028 Halftone 224 0.70 0.028 Magenta 158 0.35 0.014 Halftone 225 1.00 0.040 Magenta 159 1.00 0.040 Black 226 0.70 0.028 Magenta 160 0.18 0.007 Blue 227 0.70 0.028 Magenta 161 0.25 0.010 Blue 228 0.35 0.014 Magenta 162 0.35 0.014 Blue 229 1.00 0.040 Magenta 163 0.50 0.020 Blue 230 0.18 0.007 Black 164 0.70 0.028 Blue 231 0.25 0.010 Black 165 1.00 0.040 Blue 232 0.35 0.014 Black 166 0.70 0.028 Blue 233 0.50 0.020 Black 167 0.70 0.028 Blue 234 0.70 0.028 Black 168 0.35 0.014 Blue 235 1.00 0.040 Black 169 1.00 0.040 Blue 236 0.70 0.028 Black 170 0.18 0.007 Black 237 0.70 0.028 Halftone 171 0.25 0.010 Black 238 0.35 0.014 Halftone 172 0.35 0.014 Black 239 1.00 0.040 Black 173 0.50 0.020 Black 240 0.18 0.007 Red 174 0.70 0.028 Black 241 0.25 0.010 Red 175 1.00 0.040 Black 242 0.35 0.014 Red 176 0.70 0.028 Black 243 0.50 0.020 Red 177 0.70 0.028 Halftone 244 0.70 0.028 Red 178 0.35 0.014 Halftone 245 1.00 0.040 Red 179 1.00 0.040 Black 246 0.70 0.028 Red

Pen plotter pen (mm)

Laser/ink-jet (in.)

Plot color AutoCAD color no.

Pen plotter pen (mm)

Laser/ink-jet (in.)

Plot color

247 0.70 0.028 Red 252 0.50 0.020 Halftone 248 0.35 0.014 Red 253 0.70 0.028 Halftone 249 1.00 0.040 Red 254 1.00 0.040 Halftone 250 0.25 0.010 Halftone 255 1.00 0.040 Black 251 0.35 0.014 Halftone

4.0 Deliverable Requirements

4.1 Deliverable Preparation

All drawing files shall undergo the following checks prior to submission:

Submission Checks 1 Verify that all entities outside the drawing limits are deleted.

2 Ensure that all blocks, layers, attributes, etc not referenced in the drawing are purged.

3 Verify that all xrefs are attached without drive or directory specifications.

4 Set the menu to the standard AutoCAD menu.

5 Scan all files for viruses.

6 Users of AutoCAD 2000 or later must check that all unused layout tabs are deleted.

7 Ensure that the drawing settings are in accordance with Section 4.2 below.

4.2 Drawing Settings

The intent of these settings is to have the file open without error and for sheet files to be ready to plot.

Verify that AutoCAD commands and variables are set as follows. A script is available in Section 5.0 Files for Download.

Commands Settings BASE Insertion base point (0,0,0) GRID Off LAYER Current layer is 0 LIMITS Off, drawing limits to drawing size LINETYPE Current entity linetype BYLAYER; current linetype CONTINUOUS MENU Standard AutoCAD POINT Display mode 0, size 0.0 QTEXT Off SNAP Off TEXT Style STANDARD UCS Set UCS to world UCSICON Set UCSICON to noorigin UNITS (linear) As appropriate for drawing UNITS (angular) Decimal degrees (surveyor’s units for civil drawings) ZOOM To drawing extents

Variables Settings BLIPMODE Off (not applicable in AutoCAD 2000) ISAVEPERCENT 0, ensures every SAVE is a full SAVE PDMODE 0, controls how point objects are displayed PDSIZE 0, sets the display size for point objects TILEMODE 1 (Model Space) for model files; 0 (Paper Space) for sheet files

VISRETAIN 1

A script for setting variables automatically is available for download at www.gsa.gov/cifm. This utility is offered AS IS, is not supported and GSA makes no warranty as to its use or performance. In no event will GSA be liable for any consequential, incidental, or special damages. This utility is an aid to compliance, but is not guaranteed to work in all versions of AutoCAD, and is not guaranteed to make drawings compliant. As always the party responsible for producing the drawing is ultimately responsible for compliance with policy.

4.3 Submittal media

Submit files in accordance with regional delivery policy.

4.3.1 CD-ROM Submittal

Files submitted on CD-ROM shall be write protected CD-R format. Use the Joliet file system with normal file ordering on a single track. Preserve the original file dates and enter the project number and submission stage for the CD volume label. Submit all CD’s in individual jewel cases.

4.3.2 Labeling of Media

Include on all media the following:

Label with a fine point, black, permanent marker. Do not use any type of self-adhesive labels.

Include the following:

Building number and name PBS project number and description Submission date Submission stage

Disk number and sequence (if applicable)

Produce media cover (jewel case) labels that include the following:

Building name, number, and address PBS project name and number provided by PBS.

Contractor name, contact name and telephone number PBS project manager name Date of submittal Submission stage Description of contents Disk number and sequence (if applicable)

4.4 Project Documentation

A Project Documentation Report and Deliverables Matrix must accompany all final submittals. See Section 5.0 Files for Download.

5.0 Files for Download

Category (see www.gsa.gov/cifm or click on category heading)

All Files for Download All files, includes layer templates, title blocks, and other (cadpolicy.zip)

Layer Templates for Existing Drawings Annotation (anno_temp.dwg) Architectural (arch_temp.dwg) Architectural background (lyr_arch.dwg) Assignment background (lyr_assn.dwg) Civil (civil_temp.dwg) Civil background (lyr_civl.dwg) Electrical (elec_temp.dwg) Equipment (eqpm_temp.dwg) Fire protection (fire_temp.dwg) Fire protection background (lyr_fire.dwg) General (gen_temp.dwg) Geotechnical (geotec_temp.dwg) Hazardous (haz_temp.dwg) Interiors (intr_temp.dwg) Landscape (lndscp_temp.dwg) Mechanical HVAC (mech_temp.dw.dwg) Mechanical piping (mech_temp.dwg) Mechanical background (lyr_mech.dwg) Plumbing (plum_temp.dwg) Plumbing background (lyr_plum.dwg) Structural layer (struc_temp.dwg) Structural background (lyr_stru.dwg) Survey (surv_temp.dwg) Telecommunications (tcom-lyr.dwg) Telephone and electric background (lyr_t&e.dwg)

Layer Templates for New Drawings Annotation (anno_temp.dwt) Architectural (arch_temp.dwt) Civil (civil_temp.dwt) Electrical (elec_temp.dwt) Equipment (eqpm_temp.dwt) Fire protection (fire_temp.dwt) General (gen_temp.dwt) Geotechnical (geotec_temp.dwt) Hazardous materials (haz_temp.dwt) Interiors (intr_temp.dwt) Landscape (lndscp_temp.dwt) Mechanical (mech_temp.dwt) Plumbing template (plum_temp.dwt) Structural template (struc_temp.dwt) Survey (surv_temp.dwt) Telecommunicatons (tcom_temp.dwt)

Title Blocks Directions for title block (directions for titleblock.doc) GSA star mark logo (GSA_star.dwg)

Imperial model file 2000 (im00.dwg) Imperial model file r14 (im14.dwg) Metric model file 2000 (mm00.dwg) Metric model file r14 (mm14.dwg) http://www.gsa.gov/Portal/content/policies_content.jsp?contentOID=119345&contentType=1006 http://www.gsa.gov/Portal/content/policies_content.jsp?contentOID=119132&contentType=1006 http://www.gsa.gov/Portal/content/policies_content.jsp?contentOID=119169&contentType=1006 http://www.gsa.gov/Portal/content/policies_content.jsp?contentOID=119129&contentType=1006

Category (see www.gsa.gov/cifm or click on category heading)

Title Blocks (continued) Imperial ANSI A size 2000 (ia00.dwg) Imperial ANSI A size r14 (ia14.dwg) Imperial ANSI B size 2000 (ib00.dwg) Imperial ANSI B size r14 (ib14.dwg) Imperial Architectural C size 2000 (ic00.dwg) Imperial Architectural C size r14 (ic14.dwg) Imperial Architectural D size 2000 (id00.dwg) Imperial Architectural D size r14 (id14.dwg) Imperial Architectural E size 2000 (ie00.dwg) Imperial Architectural E size r14 (ie14.dwg) Imperial Architectural F size 2000 (if00.dwg) Imperial Architectural F size r14 (if14.dwg)

Metric ANSI A size 2000 (ma00.dwg) Metric ANSI A size r14 (ma14.dwg) Metric ANSI B size 2000 (mb00.dwg) Metric ANSI B size r14 (mb14.dwg) Metric Architectural C size 2000 (mc00.dwg) Metric Architectural C size r14 (mc14.dwg) Metric Architectural D size 2000 (md00.dwg) Metric Architectural D size r14 (md14.dwg) Metric Architectural E size 2000 (me00.dwg) Metric Architectural E size r14 (me14.dwg) Metric Architectural F size 2000 (mf00.dwg) Metric Architectural F size r14 (mf14.dwg)

Other Files for Download 1/16” Imperial (gr-scale-192.dwg) 1/8” Imperial (gr-scale-96-dwg) 1:100 Metric (gr-scale-m-100.dwg) 1:200 Metric (gr-scale-m-200.dwg) Change sheet numbers (incrementsheets.scr) Deviation request (deviationrequest_5.xls) Documentation report and deliverables matrix (documentationdeliverables.xls) Documentation of deliverables sample (docdeliverables_sample.xls) Linetypes definitions (linetypesdef.lin) Linetypes list (linetypeslist.doc) Pen settings for plotters (standard.pcp) Revise title block attributes script (revisetitleblock.scr) Set variables script (setvar.scr) Set variables script directions (setvardirections.doc) Text styles (textstyles.doc) http://www.gsa.gov/Portal/content/policies_content.jsp?contentOID=119129&contentType=1006 http://www.gsa.gov/Portal/content/policies_content.jsp?contentOID=119186&contentType=1006

1.0 The Basics
1.1 Purpose
1.2 Applicability
1.2.1 Drawing Types