About this file

Amendment 0007 dated 25 April 2016.

View the file

Other files for this federal contract opportunity

Other files attached to IRS ECC Cooling Tower Replacement, newest first.
File Type Posted
Amendment_0011_SF30_Consolidated.pdf PDF
IRS_ECC_CT_Pre-Proposal_Site_Visit_04.22.16_Sign_in_Sheets_Consolidated.pdf PDF
104416_-_FIRE_EXTINGUISHERS.PDF PDF
Amendment_0010_SF30_Consolidated.pdf PDF
GDI_Info_-_IRS_CT_Replacement.xls.xlsx XLSX spreadsheet
Amendment_0009_SF30_Consolidated.pdf PDF
Amendment_0008_SF30_Consolidated.pdf PDF
099123_-_INTERIOR_PAINTING.pdf PDF
099113_-_EXTERIOR_PAINTING.pdf PDF
Amendment_0006_SF30_Consolidated.pdf PDF
Amendment_0005_SF30_Consolidated.pdf PDF
Amendment_0004_SF30_Consolidated.pdf PDF
Amendment_0001_SF30_Consolidated.pdf PDF
GSA527-15_Contractor's_Qualifications_and_Financial_Information.pdf PDF
Amendment_0003_SF30_Consolidated.pdf PDF
Amendment_0002_SF30_Consolidated.pdf PDF
Amendment_0004_04.14.2016.pdf PDF
Amendment_0003_04.13.2016.pdf PDF
Amendment_0002_04.12.2016.pdf PDF
Amendment_0001_Consolidated_04.11.2016.pdf PDF
IRS_ECC_Cooling_Tower_Replacement_Project_Kearneysville_WV_The_Agreement_Form_C101.pdf PDF
IRS_FULL_SET_3-11-16.pdf PDF
2016-03-18_Bid_Document_Project_Manual.pdf PDF
REV_IRS_ECC_Cooling_Tower_Replacement_Project_Kearneysville_WV_The_Solicitation_Form_C201.pdf PDF
IRS_ECC_Cooling_Tower_SOW_03.22.2016.pdf PDF
IRS_ECC_Cooling_Tower_Replacement_SF_1442_with_Price_Proposal_Bid_Sheet_03.16.2016.pdf PDF
Wage_Determination_WV37_Mod_2_dtd_02.19.2016.pdf PDF
IRS_ECC_Cooling_Tower_Replacement_Project_Kearneysville_WV_Reps_ _Certs_Form_C301.pdf PDF
IRS_Pre_Solicitation_Notice_02.22.2016.pdf PDF
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION

NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.

IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

TracyLMeister Typewritten Text This page left intentionally blank.

GSA Mid-Atlantic Region

U.S. General Services Administration 100 S. Independence Mall West Philadelphia, PA 19106 www.gsa.gov

RFP Solicitation Number: GS-03-P-DX-C-7004, issued March 24, 2016 Cooling Tower Replacement Internal Revenue Service – Enterprise Computing Center Kearneysville, WV

Amendment 0007, dated April 25, 2016

This represents Amendment 0007 issued against the above referenced Request for Proposal

(RFP).

1. The due date and time for receipt of proposals remains May 11, 2016 at 2:00 PM (Local Philadelphia Time).

2. This amendment must be acknowledged with your price proposal.

3. All questions and Requests for Information (RFI’s) are to be submitted by e-mail not later than May 2, 2016 at 12:00 pm (local Philadelphia time) to the contract specialist, Tracy Meister, at tracy.meister@gsa.gov.

4. The Structural plans have been revised as follows:

a. Sheet S101, the Cooling Tower Framing Plan note # 7 has been revised to say:

• ALL STEEL IS TO BE HOT DIP GALVANIZED, INCLUDING FRAMING,

CONNECTIONS, HANDRAILS, ETC.

b. Sheet S-102, the Water Softener Platform Framing Plans note #6 has been revised to say:

• ALL STEEL IS TO BE HOT DIP GALVANIZED, INCLUDING FRAMING,

CONNECTIONS, HANDRAILS, ETC.

5. The following Paint Specifications have been added and are included as attachments to this document.

a. 099113 – Exterior Painting

b. 099123 -- Interior Painting mailto:tracy.meister@gsa.gov

6. The following answers are provided for questions submitted by contractors regarding this

RFP:

A. QUESTION:

Cooling Tower Equalizer Piping

Drawing M405 - Detail 2 & 3, Note 9 - "4" drain piping with manual shut off valve running from the bottom of the cooling tower 16" diameter equalizer piping and connected directly to sanitary piping below grade. Drain piping to sanitary piping by mechanical contractor, sanitary piping by GC typical of 3.

Detail 1, Note 14 - "run 6" equalizer drain piping from both equalizer main pipes sloping down towards sanitary drain piping by GC.

Detail 1, Note 13 - "30" diameter manway with manhole cover to access equalizer drain to sanitary sewer valves, manway depth as required to access valve"

Please clarify the number of drains from the cooling tower equalizer line.

Is the size to be 4" or 6"?

Is more than one 30" manway required?

ANSWER:

From the 16" equalizer pipe there is only one 6" drain pipe that connects to the 8" sanitary pvc main. One manway is required for the shutoff valve on the 6" drain pipe.

B. QUESTION:

6" PVC Laterals

Drawing M405 shows six, 6" PVC laterals coming from the sanitary main piping; and drawing C201 thru C204 shows three 6" PVC laterals.

Are six, 6" PVC laterals required or can the mechanical piping be joined above grade to utilize the three 6" PVC laterals as shown on the civil drawings?

Six 6" drain/overflow piping laterals are required draining into the 8" sanitary pvc main.

This does not include the 6" equalizer piping drain.

C. QUESTION:

Condenser Water Valves Spec Section 230523 3.6 Item 2 - Condenser-Water Valve Schedule specs iron, grooved-end butterfly valves, NPS 2-1/2 to NPS 12: 175 or 300 CWP; and Spec Section 230523 3.6 Item 3 - Condenser-Water Valve Schedule specs iron, grooved-end check valves, NPS 3 to NPS 12: 300 CWP.

Are flanged/lug end valves acceptable in lieu of grooved end?

Please provide a specification for butterfly valves larger than 12".

Provide flanged butterfly and check valves per following specifications. Grooved end butterfly valves and check valves are not to be used. This is an error in the specification.

REVISED CONDENSER-WATER VALVE SCHEDULE including for butterfly valves larger than 12”

A. Pipe NPS 2-1/2 and Larger:

Ductile Iron, Single-Flange Butterfly Valves, NPS 2-1/2 to NPS 12: 200 CWP, EPDM seat, aluminum-bronze disc, stainless steel stem, gear operator.

Ductile Iron, Single-Flange Butterfly Valves, NPS 14 to NPS 24: 150 CWP, EPDM seat, aluminum-bronze disc, stainless steel stem, gear operator.

Ductile Iron Swing Check Valves: Class 250, metal seats.

D. QUESTION:

Vibration Isolation on the Cooling Tower

Please clarify if vibration isolation is required for the cooling tower.

Vibration isolation is not required for the new cooling towers.

E. QUESTION:

Variable Frequency Motor Controllers (VFDs)

Does Specification Section 232923 pertain to the cooling tower and pumps?

Yes.

F. QUESTION:

Existing Chemical Treatment Contractor

Spec Section 232516 1.2 E references section 3.9 for existing Chemical Treatment contractor; however, there is no such spec section in the bid documents.

Is there an existing chemical treatment contractor working at this facility?

‘Section 3.9’ is a typographical error – should have said ‘Section 3.5’.

The existing water treatment contractor is C&E Services, Inc.

Jim Roenick 1950 Old Gallows Road, Suite 770 Vienna, VA 22182

(O) 703 506-1960 jim.roenick@gmail.com.

G. QUESTION:

VFDs

Spec Section 232923 2.6 C - Bypass Contractor Configuration states "Full Voltage" (across the line) or Reduced Voltage (autotransformer) insert type."

There is no type selected please confirm whether they want full voltage or reduced voltage.

Full Voltage..

H. QUESTION:

VFDs

Spec Section 232516 2.8 A.1 – Dry & Clean Indoor Locations: Condenser Water Pumps

- Base Bid and Option C - shall be NEMA 21.

I am assuming they mean UL/NEMA type 12, as there is no such thing as NEMA 21.

Please confirm.

Yes, NEMA 12 is correct.

IRS ENTERPRISE COMPUTER CENTER COOLING TOWER

250 Murall Drive

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

SECTION 099113 - EXTERIOR PAINTING

GENERALPART 1 -

RELATED DOCUMENTS1.1

Drawings and general provisions of the Contract, including General and SupplementaryA.

Conditions and Division 01 Specification Sections, apply to this Section.

SUMMARY1.2

Section includes surface preparation and the application of paint systems on exteriorA.

substrates.

Concrete.1.

Steel and iron.2.

Galvanized metal.3.

Aluminum (not anodized or otherwise coated).4.

Copper.5.

Stainless steel.6.

Fiberglass.7.

Plastic.8.

Portland cement plaster (stucco).9.

Related Requirements:B.

Section 051200 "Structural Steel Framing" for shop priming of metal substrates.1.

Section 055000 "Metal Fabrications" for shop priming metal fabrications.2.

DEFINITIONS1.3

MPI Gloss Level 1: Not more than five units at 60 degrees and 10 units at 85 degrees,A.

according to ASTM D 523.

MPI Gloss Level 3: 10 to 25 units at 60 degrees and 10 to 35 units at 85 degrees,B.

according to ASTM D 523.

MPI Gloss Level 4: 20 to 35 units at 60 degrees and not less than 35 units at 85 degrees,C.

according to ASTM D 523.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 1 Bid Documents

11 MARCH 2016

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

MPI Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D 523.D.

MPI Gloss Level 6: 70 to 85 units at 60 degrees, according to ASTM D 523.E.

MPI Gloss Level 7: More than 85 units at 60 degrees, according to ASTM D 523.F.

ACTION SUBMITTALS1.4

Product Data: For each type of product. Include preparation requirements and applicationA.

instructions.

Include printout of current "MPI Approved Products List" for each product category1.

specified, with the proposed product highlighted.

Indicate VOC content.2.

Samples for Initial Selection: For each type of topcoat product.B.

Samples for Verification: For each type of paint system and each color and gloss ofC.

topcoat.

Submit Samples on rigid backing, 8 inches (200 mm) square.1.

Apply coats on Samples in steps to show each coat required for system.2.

Label each coat of each Sample.3.

Label each Sample for location and application area.4.

Product List: Cross-reference to paint system and locations of application areas. UseD.

same designations indicated on Drawings and in schedules. Include color designations.

MAINTENANCE MATERIAL SUBMITTALS1.5

Furnish extra materials, from the same product run, that match products installed andA.

that are packaged with protective covering for storage and identified with labels describing contents.

Paint: 5 percent, but not less than 1 gal. (3.8 L) of each material and color applied.1.

DELIVERY, STORAGE, AND HANDLING1.6

Store materials not in use in tightly covered containers in well-ventilated areas withA.

ambient temperatures continuously maintained at not less than 45 deg F (7 deg C).

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 2

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Maintain containers in clean condition, free of foreign materials and residue.1.

Remove rags and waste from storage areas daily.2.

FIELD CONDITIONS1.7

Apply paints only when temperature of surfaces to be painted and ambient airA.

temperatures are between 50 and 95 deg F (10 and 35 deg C).

Do not apply paints in snow, rain, fog, or mist; when relative humidity exceeds 85B.

percent; at temperatures less than 5 deg F (3 deg C) above the dew point; or to damp or wet surfaces.

PRODUCTSPART 2 -

MANUFACTURERS2.1

Manufacturers: Subject to compliance with requirements, provide products by one of theA.

following:

Benjamin Moore & Co.1.

Coronado Paint; Benjamin Moore Company.2.

Glidden Professional.3.

M.A.B. Paints.4.

Sherwin-Williams Company (The).5.

Products: Subject to compliance with requirements, provide product listed in the ExteriorB.

Painting Schedule for the paint category indicated.

PAINT, GENERAL2.2

MPI Standards: Products shall comply with MPI standards indicated and shall be listed inA.

its "MPI Approved Products Lists."

Material Compatibility:B.

Materials for use within each paint system shall be compatible with one another and1.

substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 3 Bid Documents

11 MARCH 2016

http://www.specagent.com/LookUp/?uid=123457035113&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035116&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035122&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035125&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035131&mf=04&src=wd

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

For each coat in a paint system, products shall be recommended in writing by2.

topcoat manufacturers for use in paint system and on substrate indicated.

VOC Content: For field applications, paints and coatings shall comply with VOC contentC.

limits of authorities having jurisdiction and the following VOC content limits:

Flat Paints and Coatings: 50 g/L.1.

Nonflat Paints and Coatings: 50 g/L.2.

Primers, Sealers, and Undercoaters: 100 g/L.3.

Rust-Preventive Coatings: 100 g/L.4.

Zinc-Rich Industrial Maintenance Primers: 100 g/L.5.

Pretreatment Wash Primers: 420 g/L.6.

Colors: As selected by Architect from manufacturer's full range.D.

Thirty percent of surface area will be painted with deep tones.1.

SOURCE QUALITY CONTROL2.3

Testing of Paint Materials: Owner reserves the right to invoke the following procedure:A.

Owner will engage the services of a qualified testing agency to sample paint1.

materials. Contractor will be notified in advance and may be present when samples are taken. If paint materials have already been delivered to Project site, samples may be taken at Project site. Samples will be identified, sealed, and certified by testing agency.

Testing agency will perform tests for compliance with product requirements.2.

Owner may direct Contractor to stop applying paints if test results show materials3.

being used do not comply with product requirements. Contractor shall remove noncomplying paint materials from Project site, pay for testing, and repaint surfaces painted with rejected materials. Contractor will be required to remove rejected materials from previously painted surfaces if, on repainting with complying materials, the two paints are incompatible.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 4

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

EXECUTIONPART 3 -

EXAMINATION3.1

Examine substrates and conditions, with Applicator present, for compliance withA.

requirements for maximum moisture content and other conditions affecting performance of the Work.

Maximum Moisture Content of Substrates: When measured with an electronic moistureB.

meter as follows:

Concrete: 12 percent.1.

Portland Cement Plaster: 12 percent.2.

Portland Cement Plaster Substrates: Verify that plaster is fully cured.C.

Verify suitability of substrates, including surface conditions and compatibility, with existingD.

finishes and primers.

Proceed with coating application only after unsatisfactory conditions have beenE.

corrected.

Application of coating indicates acceptance of surfaces and conditions.1.

PREPARATION3.2

Comply with manufacturer's written instructions and recommendations in "MPIA.

Architectural Painting Specification Manual" applicable to substrates and paint systems indicated.

Remove hardware, covers, plates, and similar items already in place that are removableB.

and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.

After completing painting operations, use workers skilled in the trades involved to1.

reinstall items that were removed. Remove surface-applied protection.

Clean substrates of substances that could impair bond of paints, including dust, dirt, oil,C.

grease, and incompatible paints and encapsulants.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 5

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Remove incompatible primers and reprime substrate with compatible primers or1.

apply tie coat as required to produce paint systems indicated.

Concrete Substrates: Remove release agents, curing compounds, efflorescence, andD.

chalk. Do not paint surfaces if moisture content or alkalinity of surfaces to be painted exceeds that permitted in manufacturer's written instructions.

Steel Substrates: Remove rust, loose mill scale, and shop primer if any. Clean usingE.

methods recommended in writing by paint manufacturer but not less than the following:

SSPC-SP 2.1.

SSPC-SP 3.2.

SSPC-SP 7/NACE No. 4.3.

SSPC-SP 11.4.

Shop-Primed Steel Substrates: Clean field welds, bolted connections, and areas whereF.

shop paint is abraded. Paint exposed areas with the same material as used for shop priming to comply with SSPC-PA 1 for touching up shop-primed surfaces.

Galvanized-Metal Substrates: Remove grease and oil residue from galvanized sheetG.

metal by mechanical methods to produce clean, lightly etched surfaces that promote adhesion of subsequently applied paints.

Aluminum Substrates: Remove loose surface oxidation.H.

Plastic Trim Fabrication Substrates: Remove dust, dirt, and other foreign material thatI.

might impair bond of paints to substrates.

APPLICATION3.3

Apply paints according to manufacturer's written instructions and recommendations inA.

"MPI Architectural Painting Specification Manual."

Use applicators and techniques suited for paint and substrate indicated.1.

Paint surfaces behind movable items same as similar exposed surfaces. Before2.

final installation, paint surfaces behind permanently fixed items with prime coat only.

Paint both sides and edges of exterior doors and entire exposed surface of exterior3.

door frames.

Paint entire exposed surface of window frames and sashes.4.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 6

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Do not paint over labels of independent testing agencies or equipment name,5.

identification, performance rating, or nomenclature plates.

Primers specified in painting schedules may be omitted on items that are factory6.

primed or factory finished if acceptable to topcoat manufacturers.

Tint undercoats same color as topcoat, but tint each undercoat a lighter shade to facilitateB.

identification of each coat if multiple coats of same material are to be applied. Provide sufficient difference in shade of undercoats to distinguish each separate coat.

If undercoats or other conditions show through topcoat, apply additional coats until curedC.

film has a uniform paint finish, color, and appearance.

Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brushD.

marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks.

Painting Fire Suppression, Plumbing, HVAC, Electrical, Communication, and ElectronicE.

Safety and Security Work where indicated on the drawings:

Paint the following work where exposed to view:1.

Equipment, including panelboards and switch gear.a.

Uninsulated metal piping.b.

Uninsulated plastic piping.c.

Pipe hangers and supports.d.

Metal conduit.e.

Plastic conduit.f.

Tanks that do not have factory-applied final finishes.g.

FIELD QUALITY CONTROL3.4

Dry Film Thickness Testing: Owner may engage the services of a qualified testing andA.

inspecting agency to inspect and test paint for dry film thickness.

Contractor shall touch up and restore painted surfaces damaged by testing.1.

If test results show that dry film thickness of applied paint does not comply with2.

paint manufacturer's written recommendations, Contractor shall pay for testing and apply additional coats as needed to provide dry film thickness that complies with paint manufacturer's written recommendations.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 7

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

CLEANING AND PROTECTION3.5

At end of each workday, remove rubbish, empty cans, rags, and other discardedA.

materials from Project site.

After completing paint application, clean spattered surfaces. Remove spattered paints byB.

washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces.

Protect work of other trades against damage from paint application. Correct damage toC.

work of other trades by cleaning, repairing, replacing, and refinishing, as approved by Architect, and leave in an undamaged condition.

At completion of construction activities of other trades, touch up and restore damaged orD.

defaced painted surfaces.

EXTERIOR PAINTING SCHEDULE3.6

Concrete Substrates, Nontraffic Surfaces:A.

Latex System MPI EXT 3.1A:1.

Prime Coat: Primer, alkali resistant, water based, MPI #3.a.

Prime Coat: Latex, exterior, matching topcoat.b.

Intermediate Coat: Latex, exterior, matching topcoat.c.

Topcoat: Latex, exterior, low sheen (MPI Gloss Level 3-4),MPI MPI #15.d.

Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5),MPI#11.e.

Topcoat: Latex, exterior, gloss (MPI Gloss Level 6), MPI #119.f.

Concrete Substrates, Traffic Surfaces:B.

Latex Floor Paint System MPI EXT 3.2A:1.

Prime Coat: Floor paint, latex, matching topcoat.a.

Intermediate Coat: Floor paint, latex, matching topcoat.b.

Topcoat: Floor paint, latex, low gloss (maximum MPI Gloss Level 3), MPI #60.c.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 8

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Steel and Iron Substrates:C.

Alkyd System MPI EXT 5.1Q:1.

Prime Coat: Primer, alkyd, anticorrosive, for metal,MPI#79.a.

Prime Coat: Shop primer specified in Section where substrate is specified.b.

Prime Coat: Primer, metal, surface tolerant,MPI#23.c.

Intermediate Coat: Exterior, alkyd enamel, matching topcoat.d.

Topcoat: Alkyd, exterior, flat (MPI Gloss Level 1), MPI #8.e.

Topcoat: Alkyd, exterior, semi-gloss (MPI Gloss Level 5),MPI#94.f.

Topcoat: Alkyd, exterior, gloss (MPI Gloss Level 6),MPI#9.g.

Galvanized-Metal Substrates:D.

Latex System :1.

Prime Coat: Primer, galvanized, cementitious, MPI #26.a.

Prime Coat: Primer, galvanized, water based,MPI MPI #134.b.

Intermediate Coat: Latex, exterior, matching topcoat.c.

Topcoat: Latex, exterior, flat (MPI Gloss Level 1),MPI#10.d.

Topcoat: Latex, exterior, low sheen (MPI Gloss Level 3-4), MPI #15.e.

Topcoat: Latex, exterior, semi-gloss (MPI Gloss Level 5),MPI#11.f.

Topcoat: Latex, exterior, gloss (MPI Gloss Level 6), MPI #119.g.

Water-Based Light Industrial Coating System :2.

Prime Coat: Primer, galvanized, cementitious,MPI MPI #26.a.

Prime Coat: Primer, galvanized, water based, MPI #134.b.

Prime Coat: Primer, epoxy, anti-corrosive,MPI MPI #101.c.

Intermediate Coat: Light industrial coating, exterior, water based, matchingd.

topcoat.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 9

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Topcoat: Light industrial coating, exterior, water based (MPI Glosse.

Level 3),MPI#161.

Topcoat: Light industrial coating, exterior, water based, semi-gloss (MPI Glossf.

Level 5), MPI #163.

Topcoat: Light industrial coating, exterior, water based, gloss (MPI Glossg.

Level 6),MPI#164.

Alkyd System MPI EXT 5.3B:3.

Intermediate Coat: Exterior, alkyd enamel, matching topcoat.a.

Topcoat: Alkyd, exterior, flat (MPI Gloss Level 5),MPI#8.b.

Insert manufacturer's name; product name or designation.1)

Topcoat: Alkyd, exterior, semi-gloss (MPI Gloss Level 5), MPI #94.c.

Insert manufacturer's name; product name or designation.1)

Topcoat: Alkyd, exterior, gloss (MPI Gloss Level 6),MPI#9.d.

Aluminum Substrates:E.

Alkyd System MPI EXT 5.4F:1.

Pretreatment Prime Coat: Vinyl wash primer, MPI #80.a.

Prime Coat: Primer, quick dry, for aluminum,MPI MPI#95.b.

Intermediate Coat: Exterior, alkyd enamel, matching topcoat.c.

Topcoat: Alkyd, exterior, flat (MPI Gloss Level 5), MPI #8.d.

Topcoat: Alkyd, exterior, semi-gloss (MPI Gloss Level 5), MPI #94.e.

Topcoat: Alkyd, exterior, gloss (MPI Gloss Level 6),MPI MPI#9.f.

Copper Substrates:F.

Alkyd System MPI EXT 5.5F:1.

Prime Coat: Vinyl wash primer,MPI MPI #80.a.

Prime Coat: Primer, quick dry, for aluminum,MPI#95.b.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 10

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Intermediate Coat: Exterior, alkyd enamel, matching topcoat.c.

Topcoat: Alkyd, exterior, flat (MPI Gloss Level 5),MPI#8.d.

Topcoat: Alkyd, exterior, semi-gloss (MPI Gloss Level 5),MPI MPI #94.e.

Topcoat: Alkyd, exterior, gloss (MPI Gloss Level 6), MPI #9.f.

Stainless-Steel Substrates:G.

Alkyd System MPI EXT 5.6A:1.

Prime Coat: Vinyl wash primer, MPI #80.a.

Intermediate Coat: Exterior, alkyd enamel, matching topcoat.b.

Topcoat: Alkyd, exterior, flat (MPI Gloss Level 5),MPI MPI #8.c.

Topcoat: Alkyd, exterior, semi-gloss (MPI Gloss Level 5),MPI MPI #94.d.

Fiberglass Substrates:H.

Alkyd SystemMPI EXT MPI EXT 6.7B:1.

Prime Coat: Primer, bonding, solvent based,MPI MPI #69.a.

Intermediate Coat: Exterior, alkyd enamel, matching topcoat.b.

Topcoat: Alkyd, exterior, flat (MPI Gloss Level 5), MPI #8.c.

Topcoat: Alkyd, exterior, semi-gloss (MPI Gloss Level 5), MPI #94.d.

Topcoat: Alkyd, exterior, gloss (MPI Gloss Level 6), MPI #9.e.

Plastic Trim Fabrication Substrates:I.

Alkyd SystemMPI EXT MPI EXT 6.8B:1.

Prime Coat: Primer, bonding, water based, MPI #17.a.

Prime Coat: Primer, bonding, solvent based,MPI MPI #69.b.

Topcoat: Alkyd, exterior, flat (MPI Gloss Level 5),MPI#8.c.

Topcoat: Alkyd, exterior, semi-gloss (MPI Gloss Level 5),MPI MPI #94.d.

Topcoat: Alkyd, exterior, gloss (MPI Gloss Level 6),MPI MPI #9.e.

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 11

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Portland Cement Plaster Substrates:J.

High-Build Latex SystemMPI EXT MPI EXT 9.1H: Dry film thickness of not less than1.

10 mils (0.25 mm).

Prime Coat: As recommended in writing by topcoat manufacturer.a.

Topcoat: Latex, exterior, high build,MPI#40.b.

END OF SECTION 099113

EXTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099113 - 12

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

SECTION 099123 - INTERIOR PAINTING

GENERALPART 1 -

RELATED DOCUMENTS1.1

Drawings and general provisions of the Contract, including General and SupplementaryA.

Conditions and Division 01 Specification Sections, apply to this Section.

SUMMARY1.2

Section includes surface preparation and the application of paint systems on interiorA.

substrates.

Concrete.1.

Cement board.2.

Clay masonry.3.

Concrete masonry units (CMUs).4.

Steel and iron.5.

Galvanized metal.6.

Aluminum (not anodized or otherwise coated).7.

Copper.8.

Stainless steel.9.

Fiberglass.10.

Plastic.11.

Gypsum board.12.

Plaster.13.

Related Requirements:B.

Section 051200 "Structural Steel Framing" for shop priming structural steel.1.

Section 055000 "Metal Fabrications" for shop priming metal fabrications.2.

Section 055213 "Pipe and Tube Railings" for shop painting pipe and tube railings.3.

for shop priming metal gratings.4.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 1

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

DEFINITIONS1.3

MPI Gloss Level 1: Not more than five units at 60 degrees and 10 units at 85 degrees,A.

according to ASTM D 523.

MPI Gloss Level 2: Not more than 10 units at 60 degrees and 10 to 35 units at 85B.

degrees, according to ASTM D 523.

MPI Gloss Level 3: 10 to 25 units at 60 degrees and 10 to 35 units at 85 degrees,C.

according to ASTM D 523.

MPI Gloss Level 4: 20 to 35 units at 60 degrees and not less than 35 units at 85 degrees,D.

according to ASTM D 523.

MPI Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D 523.E.

MPI Gloss Level 6: 70 to 85 units at 60 degrees, according to ASTM D 523.F.

MPI Gloss Level 7: More than 85 units at 60 degrees, according to ASTM D 523.G.

ACTION SUBMITTALS1.4

Product Data: For each type of product. Include preparation requirements and applicationA.

instructions.

Include Printout of current "MPI Approved Products List" for each product category1.

specified, with the proposed product highlighted.

Indicate VOC content.2.

Samples for Initial Selection: For each type of topcoat product.B.

Samples for Verification: For each type of paint system and in each color and gloss ofC.

topcoat.

Submit Samples on rigid backing, 8 inches (200 mm) square.1.

Apply coats on Samples in steps to show each coat required for system.2.

Label each coat of each Sample.3.

Label each Sample for location and application area.4.

Product List: Cross-reference to paint system and locations of application areas. UseD.

same designations indicated on Drawings and in schedules. Include color designations.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 2

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

MAINTENANCE MATERIAL SUBMITTALS1.5

Furnish extra materials, from the same product run, that match products installed andA.

that are packaged with protective covering for storage and identified with labels describing contents.

Paint: 5 percent, but not less than 1 gal. (3.8 L) of each material and color applied.1.

DELIVERY, STORAGE, AND HANDLING1.6

Store materials not in use in tightly covered containers in well-ventilated areas withA.

ambient temperatures continuously maintained at not less than 45 deg F (7 deg C).

Maintain containers in clean condition, free of foreign materials and residue.1.

Remove rags and waste from storage areas daily.2.

FIELD CONDITIONS1.7

Apply paints only when temperature of surfaces to be painted and ambient airA.

temperatures are between 50 and 95 deg F (10 and 35 deg C).

Do not apply paints when relative humidity exceeds 85 percent; at temperatures less thanB.

5 deg F (3 deg C) above the dew point; or to damp or wet surfaces.

PRODUCTSPART 2 -

MANUFACTURERS2.1

Manufacturers: Subject to compliance with requirements, provide products by one of theA.

following:

Benjamin Moore & Co.1.

Coronado Paint; Benjamin Moore Company.2.

Glidden Professional.3.

M.A.B. Paints.4.

PPG Architectural Finishes, Inc.5.

Sherwin-Williams Company (The).6.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 3 Bid Documents

11 MARCH 2016

http://www.specagent.com/LookUp/?uid=123457035134&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035137&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035143&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035146&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035148&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457035152&mf=04&src=wd

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Products: Subject to compliance with requirements, provide one of the products listed inB.

the Interior Painting Schedule for the paint category indicated.

PAINT, GENERAL2.2

MPI Standards: Products shall comply with MPI standards indicated and shall be listed inA.

its "MPI Approved Products Lists."

Material Compatibility:B.

Materials for use within each paint system shall be compatible with one another and1.

substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.

For each coat in a paint system, products shall be recommended in writing by2.

topcoat manufacturers for use in paint system and on substrate indicated.

VOC Content: For field applications that are inside the weatherproofing system, paintsC.

and coatings shall comply with VOC content limits of authorities having jurisdiction and the following VOC content limits:

Flat Paints and Coatings: 50 g/L.1.

Nonflat Paints and Coatings: 50 g/L.2.

Primers, Sealers, and Undercoaters: 100 g/L.3.

Rust-Preventive Coatings: 100 g/L.4.

Zinc-Rich Industrial Maintenance Primers: 100 g/L.5.

Pretreatment Wash Primers: 420 g/L.6.

Colors: As selected by Architect from manufacturer's full range.D.

Thirty percent of surface area will be painted with deep tones.1.

SOURCE QUALITY CONTROL2.3

Testing of Paint Materials: Owner reserves the right to invoke the following procedure:A.

Owner will engage the services of a qualified testing agency to sample paint1.

materials. Contractor will be notified in advance and may be present when samples are taken. If paint materials have already been delivered to Project site, samples may be taken at Project site. Samples will be identified, sealed, and certified by testing agency.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 4

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Testing agency will perform tests for compliance with product requirements.2.

Owner may direct Contractor to stop applying paints if test results show materials3.

being used do not comply with product requirements. Contractor shall remove noncomplying paint materials from Project site, pay for testing, and repaint surfaces painted with rejected materials. Contractor will be required to remove rejected materials from previously painted surfaces if, on repainting with complying materials, the two paints are incompatible.

EXECUTIONPART 3 -

EXAMINATION3.1

Examine substrates and conditions, with Applicator present, for compliance withA.

requirements for maximum moisture content and other conditions affecting performance of the Work.

Maximum Moisture Content of Substrates: When measured with an electronic moistureB.

meter as follows:

Concrete: 12 percent.1.

Fiber-Cement Board: 12 percent.2.

Masonry (Clay and CMUs): 12 percent.3.

Gypsum Board: 12 percent.4.

Plaster: 12 percent.5.

Gypsum Board Substrates: Verify that finishing compound is sanded smooth.C.

Plaster Substrates: Verify that plaster is fully cured.D.

Verify suitability of substrates, including surface conditions and compatibility, with existingE.

finishes and primers.

Proceed with coating application only after unsatisfactory conditions have beenF.

corrected.

Application of coating indicates acceptance of surfaces and conditions.1.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 5

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

PREPARATION3.2

Comply with manufacturer's written instructions and recommendations in "MPIA.

Architectural Painting Specification Manual" applicable to substrates and paint systems indicated.

Remove hardware, covers, plates, and similar items already in place that are removableB.

and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.

After completing painting operations, use workers skilled in the trades involved to1.

reinstall items that were removed. Remove surface-applied protection if any.

Clean substrates of substances that could impair bond of paints, including dust, dirt, oil,C.

grease, and incompatible paints and encapsulants.

Remove incompatible primers and reprime substrate with compatible primers or1.

apply tie coat as required to produce paint systems indicated.

Concrete Substrates: Remove release agents, curing compounds, efflorescence, andD.

chalk. Do not paint surfaces if moisture content or alkalinity of surfaces to be painted exceeds that permitted in manufacturer's written instructions.

Masonry Substrates: Remove efflorescence and chalk. Do not paint surfaces if moistureE.

content or alkalinity of surfaces or mortar joints exceeds that permitted in manufacturer's written instructions.

Steel Substrates: Remove rust, loose mill scale, and shop primer, if any. Clean usingF.

methods recommended in writing by paint manufacturer but not less than the following:

SSPC-SP 2.1.

SSPC-SP 3.2.

SSPC-SP 7/NACE No. 4.3.

SSPC-SP 11.4.

Shop-Primed Steel Substrates: Clean field welds, bolted connections, and areas whereG.

shop paint is abraded. Paint exposed areas with the same material as used for shop priming to comply with SSPC-PA 1 for touching up shop-primed surfaces.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 6

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Galvanized-Metal Substrates: Remove grease and oil residue from galvanized sheetH.

metal by mechanical methods to produce clean, lightly etched surfaces that promote adhesion of subsequently applied paints.

Aluminum Substrates: Remove loose surface oxidation.I.

APPLICATION3.3

Apply paints according to manufacturer's written instructions and to recommendations inA.

"MPI Manual."

Use applicators and techniques suited for paint and substrate indicated.1.

Paint surfaces behind movable equipment and furniture same as similar exposed2.

surfaces. Before final installation, paint surfaces behind permanently fixed equipment or furniture with prime coat only.

Paint front and backsides of access panels, removable or hinged covers, and3.

similar hinged items to match exposed surfaces.

Do not paint over labels of independent testing agencies or equipment name,4.

identification, performance rating, or nomenclature plates.

Primers specified in painting schedules may be omitted on items that are factory5.

primed or factory finished if acceptable to topcoat manufacturers.

Tint each undercoat a lighter shade to facilitate identification of each coat if multiple coatsB.

of same material are to be applied. Tint undercoats to match color of topcoat, but provide sufficient difference in shade of undercoats to distinguish each separate coat.

If undercoats or other conditions show through topcoat, apply additional coats until curedC.

film has a uniform paint finish, color, and appearance.

Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brushD.

marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks.

Painting Fire Suppression, Plumbing, HVAC, Electrical, Communication, and ElectronicE.

Safety and Security Work:

Paint the following work where exposed in equipment rooms:1.

Equipment, including panelboards and switch gear.a.

Uninsulated metal piping.b.

Uninsulated plastic piping.c.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 7

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Pipe hangers and supports.d.

Metal conduit.e.

Plastic conduit.f.

Tanks that do not have factory-applied final finishes.g.

Duct, equipment, and pipe insulation having cotton or canvas insulationh.

covering or other paintable jacket material.

Paint the following work where exposed in occupied spaces:2.

Equipment, including panelboards.a.

Uninsulated metal piping.b.

Uninsulated plastic piping.c.

Pipe hangers and supports.d.

Metal conduit.e.

Plastic conduit.f.

Duct, equipment, and pipe insulation having cotton or canvas insulationg.

covering or other paintable jacket material.

Other items as directed by Architect.h.

Paint portions of internal surfaces of metal ducts, without liner, behind air inlets and3.

outlets that are visible from occupied spaces.

FIELD QUALITY CONTROL3.4

Dry Film Thickness Testing: Owner may engage the services of a qualified testing andA.

inspecting agency to inspect and test paint for dry film thickness.

Contractor shall touch up and restore painted surfaces damaged by testing.1.

If test results show that dry film thickness of applied paint does not comply with2.

paint manufacturer's written recommendations, Contractor shall pay for testing and apply additional coats as needed to provide dry film thickness that complies with paint manufacturer's written recommendations.

CLEANING AND PROTECTION3.5

At end of each workday, remove rubbish, empty cans, rags, and other discardedA.

materials from Project site.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 8

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

After completing paint application, clean spattered surfaces. Remove spattered paints byB.

washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces.

Protect work of other trades against damage from paint application. Correct damage toC.

work of other trades by cleaning, repairing, replacing, and refinishing, as approved by Architect, and leave in an undamaged condition.

At completion of construction activities of other trades, touch up and restore damaged orD.

defaced painted surfaces.

INTERIOR PAINTING SCHEDULE3.6

Concrete Substrates, Nontraffic Surfaces:A.

High-Performance Architectural Latex System MPI INT 3.1C:1.

Prime Coat: Primer, alkali resistant, water based,MPI#3.a.

Intermediate Coat: Latex, interior, high performance architectural, matchingb.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossc.

Level 2), MPI #138.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 3), MPI #139.

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 4),MPI#140.

Topcoat: Latex, interior, high performance architectural, semi-glossf.

(MPI Gloss Level 5),MPI MPI #141.

Concrete Stain System :2.

First Coat: Stain, interior, matching topcoat.a.

Topcoat: Stain, interior,MPI#58.b.

Concrete Substrates, Traffic Surfaces:B.

Concrete Stain System :1.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 9

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

First Coat: Stain, interior, for concrete floors, matching topcoat.a.

Topcoat: Stain, interior, for concrete floors, MPI #58.b.

Water-Based Concrete Floor Sealer System MPI INT3.2G:2.

First Coat: Sealer, water based, for concrete floors, matching topcoat.a.

Topcoat: Sealer, water based, for concrete floors,MPI#99.b.

Cement Board Substrates:C.

High-Performance Architectural Latex System MPI INT 3.3B:1.

Prime Coat: Primer, alkali resistant, water based, MPI #3.a.

Intermediate Coat: Latex, interior, high performance architectural, matchingb.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossc.

Level 2), MPI #138.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 3),MPI MPI #139.

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 4), MPI #140.

Topcoat: Latex, interior, high performance architectural, semi-glossf.

(MPI Gloss Level 5),MPI#141.

Clay Masonry Substrates:D.

High-Performance Architectural Latex System MPI INT 4.1L:1.

Prime Coat: Primer, alkali resistant, water based, MPI #3.a.

Intermediate Coat: Latex, interior, high performance architectural, matchingb.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossc.

Level 2), MPI #138.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 3),MPI#139.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 10

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 4),MPI#140.

Topcoat: Latex, interior, high performance architectural, semi-glossf.

(MPI Gloss Level 5), MPI #141.

CMU Substrates:E.

High-Performance Architectural Latex System MPI INT 4.2D MPI INT 4.2P:1.

Block Filler: Block filler, latex, interior/exterior, MPI #4.a.

Prime Coat: Primer, alkali resistant, water based,MPI#3.b.

Intermediate Coat: Latex, interior, high performance architectural, matchingc.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 2), MPI #138.

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 3),MPI#139.

Topcoat: Latex, interior, high performance architectural (MPI Glossf.

Level 4), MPI #140.

Topcoat: Latex, interior, high performance architectural, semi-glossg.

(MPI Gloss Level 5),MPI#141.

Steel Substrates:F.

High-Performance Architectural Latex System MPI INT 5.1R MPI INT 5.1RR:1.

Prime Coat: Primer, alkyd, quick dry, for metal, MPI #76.a.

Prime Coat: Primer, alkyd, anti-corrosive, for metal,MPI#79.b.

Prime Coat: Shop primer specified in Section where substrate is specified.c.

Intermediate Coat: Latex, interior, high performance architectural, matchingd.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 2), MPI #138.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 11

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Topcoat: Latex, interior, high performance architectural (MPI Glossf.

Level 3), MPI #139.

Topcoat: Latex, interior, high performance architectural (MPI Glossg.

Level 4),MPI MPI #140.

Topcoat: Latex, interior, high performance architectural, semi-glossh.

(MPI Gloss Level 5), MPI #141.

Galvanized-Metal Substrates:G.

High-Performance Architectural Latex System MPI INT 5.3M:1.

Prime Coat: Primer, galvanized, water based,MPI#134.a.

Intermediate Coat: Latex, interior, high performance architectural, matchingb.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossc.

Level 2), MPI #138.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 3),MPI#139.

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 4), MPI #140.

Topcoat: Latex, interior, high performance architectural, semi-glossf.

(MPI Gloss Level 5),MPI#141.

Aluminum (Not Anodized or Otherwise Coated) Substrates:H.

High-Performance Architectural Latex System MPI INT 5.4F:1.

Prime Coat: Primer, quick dry, for aluminum, MPI #95.a.

Intermediate Coat: Latex, interior, high performance architectural, matchingb.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossc.

Level 2), MPI #138.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 3),MPI#139.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 12

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 4), MPI #140.

Topcoat: Latex, interior, high performance architectural, semi-glossf.

(MPI Gloss Level 5),MPI#141.

Copper Substrates:I.

High-Performance Architectural Latex System MPI INT 5.5F:1.

Prime Coat: Primer, quick dry, for aluminum, MPI #95.a.

Intermediate Coat: Latex, interior, high performance architectural, matchingb.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossc.

Level 2), MPI #138.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 3),MPI MPI #139.

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 4), MPI #140.

Topcoat: Latex, interior, high performance architectural, semi-glossf.

(MPI Gloss Level 5),MPI MPI#141.

Stainless-Steel Substrates:J.

High-Performance Architectural Latex System MPI INT 5.6G:1.

Prime Coat: Primer, bonding, solvent based, MPI #69.a.

Intermediate Coat: Latex, interior, high performance architectural, matchingb.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossc.

Level 2),MPI MPI #138.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 3), MPI #139.

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 4),MPI#140.

INTERIOR PAINTING

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

099123 - 13

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Topcoat: Latex, interior, high performance architectural, semi-glossf.

(MPI Gloss Level 5), MPI #141.

Fiberglass Substrates:K.

High-Performance Architectural Latex System MPI INT 6.7H:1.

Prime Coat: Primer, bonding, water based,MPI#17.a.

Prime Coat: Primer, bonding, solvent based, MPI #69.b.

Intermediate Coat: Latex, interior, high performance architectural, matchingc.

topcoat.

Topcoat: Latex, interior, high performance architectural (MPI Glossd.

Level 2),MPI#138.

Topcoat: Latex, interior, high performance architectural (MPI Glosse.

Level 3), MPI #139.

Topcoat: Latex, interior, high performance architectural (MPI Glossf.

Level 4), MPI #140.

Topcoat: Latex, interior, high performance architectural, semi-glossg.

(MPI Gloss Level 5),MPI MPI#141.

Plastic Substrates:L.

High-Performance Architectural Latex System MPI INT 6.8A:1.

Prime Coat: Primer, bonding, solvent based,MPI MPI#69.a.

Intermediate Coat: Latex, interior, high…