104416_-_FIRE_EXTINGUISHERS.PDF

PDF 69 KB Posted

Attached to
IRS ECC Cooling Tower Replacement Federal contract opportunity
Solicitation number
GS-03-P-16-DX-C-7004
Issued by
General Services Administration Public Buildings Service Region 3

About this file

Specification Section 104416 - Fire Extinguishers

View the file

Other files for this federal contract opportunity

Other files attached to IRS ECC Cooling Tower Replacement, newest first.
File Type Posted
IRS_ECC_CT_Pre-Proposal_Site_Visit_04.22.16_Sign_in_Sheets_Consolidated.pdf PDF
Amendment_0011_SF30_Consolidated.pdf PDF
Amendment_0010_SF30_Consolidated.pdf PDF
GDI_Info_-_IRS_CT_Replacement.xls.xlsx XLSX spreadsheet
Amendment_0009_SF30_Consolidated.pdf PDF
Amendment_0008_SF30_Consolidated.pdf PDF
099123_-_INTERIOR_PAINTING.pdf PDF
099113_-_EXTERIOR_PAINTING.pdf PDF
Amendment_0007_SF30_Consolidated.pdf PDF
Amendment_0006_SF30_Consolidated.pdf PDF
Amendment_0005_SF30_Consolidated.pdf PDF
Amendment_0001_SF30_Consolidated.pdf PDF
GSA527-15_Contractor's_Qualifications_and_Financial_Information.pdf PDF
Amendment_0003_SF30_Consolidated.pdf PDF
Amendment_0002_SF30_Consolidated.pdf PDF
Amendment_0004_04.14.2016.pdf PDF
Amendment_0004_SF30_Consolidated.pdf PDF
Amendment_0003_04.13.2016.pdf PDF
Amendment_0002_04.12.2016.pdf PDF
Amendment_0001_Consolidated_04.11.2016.pdf PDF
IRS_FULL_SET_3-11-16.pdf PDF
2016-03-18_Bid_Document_Project_Manual.pdf PDF
REV_IRS_ECC_Cooling_Tower_Replacement_Project_Kearneysville_WV_The_Solicitation_Form_C201.pdf PDF
IRS_ECC_Cooling_Tower_SOW_03.22.2016.pdf PDF
IRS_ECC_Cooling_Tower_Replacement_SF_1442_with_Price_Proposal_Bid_Sheet_03.16.2016.pdf PDF
Wage_Determination_WV37_Mod_2_dtd_02.19.2016.pdf PDF
IRS_ECC_Cooling_Tower_Replacement_Project_Kearneysville_WV_Reps_ _Certs_Form_C301.pdf PDF
IRS_ECC_Cooling_Tower_Replacement_Project_Kearneysville_WV_The_Agreement_Form_C101.pdf PDF
IRS_Pre_Solicitation_Notice_02.22.2016.pdf PDF
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IRS ENTERPRISE COMPUTER CENTER COOLING TOWER

250 Murall Drive

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

SECTION 104416 - FIRE EXTINGUISHERS (Applies to Base Bid)

GENERALPART 1 -

RELATED DOCUMENTS1.1

Drawings and general provisions of the Contract, including General and SupplementaryA.

Conditions and Division 01 Specification Sections, apply to this Section.

SUMMARY1.2

Section includes portable, hand-carried fire extinguishers and mounting brackets for fireA.

extinguishers.

SUBMITTALS1.3

Product Data: For each type of product indicated. Include rating and classification,A.

material descriptions, dimensions of individual components and profiles, and finishes for fire extinguisher and mounting brackets.

Operation and Maintenance Data: For fire extinguishers to include in maintenanceB.

manuals.

Warranty: Sample of special warranty.C.

QUALITY ASSURANCE1.4

NFPA Compliance: Fabricate and label fire extinguishers to comply with NFPA 10,A.

"Portable Fire Extinguishers."

Fire Extinguishers: Listed and labeled for type, rating, and classification by anB.

independent testing agency acceptable to authorities having jurisdiction.

Provide fire extinguishers approved, listed, and labeled by FMG.1.

FIRE EXTINGUISHERS

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

104416 - 1 Bid Documents

11 MARCH 2016

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

WARRANTY1.5

Special Warranty: Manufacturer's standard form in which manufacturer agrees to repairA.

or replace fire extinguishers that fail in materials or workmanship within specified warranty period.

Failures include, but are not limited to, the following:1.

Failure of hydrostatic test according to NFPA 10.a.

Faulty operation of valves or release levers.b.

Warranty Period: Six years from date of Substantial Completion.2.

PRODUCTSPART 2 -

PORTABLE, HAND-CARRIED FIRE EXTINGUISHERS2.1

Fire Extinguishers: Type, size, and capacity for each mounting bracket indicated.A.

Valves: Chrome Plated Brass.1.

Handles and Levers: Stainless Steel.2.

Instruction Labels: Include pictorial marking system complying with NFPA 10,3.

Appendix B and bar coding for documenting fire extinguisher location, inspections, maintenance, and recharging.

Bi-lingual Labels: Spanish and English.4.

Multipurpose Dry-Chemical Type in Steel Container: UL-rated 4-A:80-B:C, 10-lb nominalB.

capacity, with monoammonium phosphate-based dry chemical in steel container. Finish shall be red durable High Gloss Polyester Powder Paint.

MOUNTING BRACKETS2.2

Mounting Brackets: Manufacturer's standard steel, designed to secure fire extinguisherA.

to wall or structure, of sizes required for types and capacities of fire extinguishers indicated, with plated or red baked-enamel finish.

Identification: Lettering complying with authorities having jurisdiction for letter style, size,B.

spacing, and location. Locate as indicated on drawings.

FIRE EXTINGUISHERS

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

104416 - 2

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

Identify bracket-mounted fire extinguishers with the words "FIRE EXTINGUISHER"1.

in red letter decals applied to mounting surface.

Orientation: Vertical.a.

EXECUTIONPART 3 -

EXAMINATION3.1

Examine fire extinguishers for proper charging and tagging.A.

Remove and replace damaged, defective, or undercharged fire extinguishers.1.

Proceed with installation only after unsatisfactory conditions have been corrected.B.

INSTALLATION3.2

General: Install fire extinguishers and mounting bracket in locations indicated and inA.

compliance with requirements of authorities having jurisdiction.

Mounting Brackets: 54 inches above finished floor to top of fire extinguisher.1.

Mounting Brackets: Fasten mounting brackets to surfaces, square and plumb, atB.

locations indicated.

The location intent is to maximize line of sight to the extinguisher. The contractor is atC.

liberty to propose an alternate location subject to construction management team approval.

END OF SECTION 104416

FIRE EXTINGUISHERS

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

104416 - 3

Kearneysville, West Virginia

GSA # GS-P-03-15-DX-5027

THIS PAGE INTENTIONALLY LEFT BLANK

FIRE EXTINGUISHERS

PROPERTY OF THE U.S. GOVERNMENT - FOR OFFICIAL USE ONLY

Do not remove this notice - Properly destroy documents when no longer needed

104416 - 4

RELATED DOCUMENTS
SUMMARY
SUBMITTALS
Operation and Maintenance Data: For fire extinguishers to include in maintenance manuals.
Warranty: Sample of special warranty.
QUALITY ASSURANCE
Fire Extinguishers: Listed and labeled for type, rating, and classification by an independent test
WARRANTY
Faulty operation of valves or release levers.