DRAFT_(NJ)_-_Line_Item_Bid_Sheet_(NJ)-_2017_IDIQ_Contract.xlsx

XLSX spreadsheet 104 KB Posted

Attached to
Solicitation Notice R&A IDIQ (NJ) Federal contract opportunity
Solicitation number
GS-02-P-17-DT-D-0006
Issued by
General Services Administration Public Buildings Service Region 2

About this file

This is a DRAFT RFP and SOW. This notice does not constitute a solicitation. This announcement is an opportunity for industry to review the DRAFT RFP and SOW and provide the Government with comments/suggestions and/or questions. Any comments/suggestions/questions will be used for planning purposes only. Response to this notice is strictly voluntary. DISCLOSURE NOTIFICATION AND PROCEDURES Please do not submit proprietary information. Any information provided may be used for the project without.

View the file

Other files for this federal contract opportunity

Other files attached to Solicitation Notice R&A IDIQ (NJ), newest first.
File Type Posted
QUESTIONS_AND_ANSWERS.pdf PDF
DRAFT_(NJ)_SPEC_10OCT16_IDIQR2_SOW_New_Jersey.pdf PDF
DRAFT_(NJ)_C201_Small_Business_Set_Aside_GC_Sol_GS-P-02-17-DT-D-0006_NJ.pdf PDF
Pre-SolicitationNoticeRAIDIQNJ.docx.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1 INSTRUCTIONS TO OFFERORS: Complete the below sheet by providing the price per unit for each line item listed, for each period of performance. Only columns F, G, H, I and J can be edited. The Total Evaluated Price will be automatically calculated. As applicable, complete the "Travel Multipliers" section, to be utilized for future task orders.

Item
No.:Description:Units:Div.:Est.

Annual Quantity: Price Per Unit (Base Year) Price Per Unit (Option Year I) Price Per Unit (Option Year II) Price Per Unit (Option Year III) Price Per Unit (Option Year IV) Extended Price (Base Year) Extended Price (Option Year I) Extended Price (Option Year II) Extended Price (Option Year III) Extended Price (Option Year IV)

1.0Removal of partition metal stud and drywall with or without plaster skim coat, including demountable partitions and repair damage to other wall surfaces. Remove all debris from Government property.SFD1000.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
2.0Removal of partition metal stud and drywall with or without plaster skim coat and flattened expanded metal fastened to metal studs, including demountable partitions and repair damage to other wall surfaces. Remove all debris from Government property.SFD100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
3.0Removal of drywall with or without plaster skim coat on one side of partition or wall, including repairing damage to other wall surfaces. Remove all debris from Government property.SFD500.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
4.0Remove door and frame from drywall and/or demountable partition. Door and frame shall be removed from Government property unless requested to be returned to the Government.EAD100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
5.0Remove lockset from existing door and return to the Government.EAD100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
6.0Removal of bookcases, remove from Government property unless requested to be returned to the Government. Price shall be determined by the square feet face or front view of bookcase.SFD300.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
7.0Remove carpet tack-less method, glued down, or carpet tile including cleaning of the floor surface and remove from the Government property.SYD250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
8.0Remove carpet pad any type and remove all debris from Government property, including cleaning of the floor surface.SYD250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
9.0Remove cove base molding or carpet base and remove from the Government property.LFD250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
10.0Remove resilient floor tile, including cleaning of the floor surface and remove all debris from Government property.SFD200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
11.0Remove wall covering, vinyl or fabric, including cleaning of the wall surface and remove from the Government property.SFD300.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
12.0Remove ceiling tile and suspension system, any type, and remove from the Government property.SFD250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
13.0Remove ceiling tile only and remove from the Government property.SFD250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
14.0Remove electrical switch any type and provide cover when needed. Remove electrical wall receptacle any type and provide cover when needed including wiring up to 50'-0".EAD60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
15.0Remove telephone wall, data, or communication outlet and provide cover when needed.EAD60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
16.0Remove electrical floor receptacle flush or pedestal and provide cap and plug assemble. Remove telephone floor outlet flush or pedestal and provide cap and plug assemble.EAD40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
17.0Remove tele-power pole any type and replace ceiling tile.EAD20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
18.0Remove light fixture any type including exit, emergency light.EAD60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
19.0Remove sprinkler head and all associated piping to the main and cap the remaining line piping. Coordinate system shut-down with GSA and building maintenance.EAD20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
20.0Disconnect electrical power, telephone, data, and CAT-2,3,4,5 or 6 cable from system furniture cubicle including 75'-0" of cable.EAD40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
21.0Disassemble and remove existing system furniture cubicle including sorting all parts and transporting to building storage area as designated by Government. Price determined by square footage of cubicle.LFD1750.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
22.0Furnish and install partition 3⅝" 16 gage metal stud 16" O.C. with flattened expanded metal. Expanded metal 75-9 gauge from the top of the existing partition to the slab above. Removal and reinstallation of the ceiling and all cut outs shall be included in the cost.SFF&I80.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
23.0Furnish and install partition or ceiling 3⅝", 25 gage metal stud 16" O.C., ⅝" drywall on both sides, including tape and spackle finish of drywall with primer or sealer coat of paint and two finish coats of paint. Furnish and install 4" cove base. This line item shall also be used to close openings in the wall, where doors, window, etc. are removed. Price shall be determined by the square feet of one side.SFF&I2500.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
24.0Furnish and install partition or ceiling ⅞", 25 gage metal furring strip 16" O.C., ⅝" drywall on one side, including tape and spackle finish of drywall with primer or sealer coat of paint and two finish coats of paint. Furnish and install 4" cove base. Price shall be determined by the square feet of drywall installed.SFF&I120.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
25.0Furnish and install ⅝" drywall on one side of partition or wall, including tape and spackle finish of drywall with primer or sealer coat of paint and two finish coats of paint. Furnish and install 4" cove base. Price shall be determined by the square feet of drywall installed.SFF&I200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
26.0Furnish and install flattened expanded metal 75-9 gauge anchored onto existing metal studs. For a finished partition combine with item number 23.SFF&I200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
27.0Cut and patch opening into existing drywall or plaster, patching of the surface shall include all necessary work for a flush smooth surface to match the existing finish.SFF&I120.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
28.0Furnish and install access panel hinged type with latching mechanism In drywall, plaster or CMU wall, including cutting opening, patching, one coat primer and two finish coats of paint.SFF&I20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
29.0Furnish and install vision viewing window in any partition with safety glass tempered, tinted or clear and wood or metal frame, shape to be determined by the Government, including cutting opening into the partition, one coat primer or sealer paint and two finish coats of paint on frame.SFF&I40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
30.0Furnish and install mineral fiber sound insulation 3½" thick for walls or ceiling.SFF&I1200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
31.0Install Government furnished door and frame into any partition including cutting opening into partition, painting the frame with two coats, painting or varnishing the door with two coats and installing all of the door hardware.EAF&I20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
32.0Furnish and Install caulking around exterior surfaces such as areas of roofing. Polyurethane Interior/Exterior Window and Door Caulk, White, Black, Tan, Bronze, Limestone, Gray Multiple external and internal applications including sealing door and window frames, roofing substrates, and cladding joints Bonds to metals, masonry, wood, vinyl, cement fiber board, granite and marble. Low solvent content - under CARB limits. Non-Shrinking

High movement and flexibility. Paintable with multiple coating types. Cures in less than 72 hours

Skin time in less than 24 hoursLFF&I100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
33.0Furnish and install door vision into any door with safety glass tempered or fire rated wired, lite tinted or clear glass and wood or metal frame, shape to be determined by the Government. Including cutting opening into the door, one coat primer or sealer paint and two finish coats of paint on frame.SFF&I40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
34.0Furnish and install air louver in any door, wood or metal frame. Including cutting opening into the door, one coat primer or sealer paint and two finish coats of paint on frame.SFF&I40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
35.0Furnish and install door stop or bumper, floor or wall mounted.EAF&I20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
36.0Furnish and install push button cipher lockset Simplex model L1000 with key override, onto any door.EAF&I20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
37.0Install Government furnished carpet tile per the manufactures instructions, contractor to supply all other items including adhesive, any preparation of the floor surface, etc., including removing and reinstalling all floor outlet covers.SYF&I1250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
38.0Install Government furnished broadloom carpet per the manufactures instructions, contractor to supply all necessary items including adhesive, tack strip, any preparation of the floor surface, etc., including removing and reinstalling all floor outlet covers. (Carpet maybe glued or tacked.)SYF&I1000.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
39.0Furnish and install carpet pad rubber 80 oz. including preparation of the floor surface, adhesive, etc.SYF&I300.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
40.0Install Government supplied carpet pad rubber 80 oz. including preparation of the floor surface, adhesive, etc.SYF&I800.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
41.0Install carpet cove base from the Government supplied material. The contractor to supply all necessary adhesive, staples, and preparation to the surface.LFF&I350.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
42.0Add to line item 51 if carpet binding is required.LFF&I300.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
43.0Raise and lower system furniture for removal and the installation of carpet. Cost is based per linear foot of system furniture partition.LFF&I200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
44.0Furnish and install vinyl cove base ⅛" x 4" or 6" with molded corners. Contractor to supply samples or Government will provide selection of a manufacture and color.LFF&I1250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
45.0Furnish and install vinyl floor tile 12" x 12" x ⅛" including adhesive and preparation to the floor. Contractor to supply samples or Government will provide selection of a manufacture and color.SFF&I800.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
46.0Add to line item 55 if the access panels for the replacement of the VTC will be on the floor duct system.SFF&I160.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
47.0Furnish and install carpet binder bar beveled vinyl or beveled metal. Contractor to supply samples.LFF&I30.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
48.0Paint ceiling or walls with two coats of low VOC paint as per the order flat, semi-gloss, egg shell, etc. Any conduits, boxes anchored to the wall shall be included if the color is to be the same, preparation shall be also included. The contractor shall provide finish selections to the Government Representative, or the Government will provide selection to the contractor.SFF&I2500.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
49.0Paint ceiling grid with two coats including cleaning and preparing surface. The cost shall be determined by the square feet of the ceiling to be painted. The contractor shall provide finish selections to the Government Representative, or the Government will provide selection to the contractor.SFF&I1000.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
50.0Paint or varnish door two coats, finish to be determined per each order. The cost shall be per side (if two sides are required the cost will double). The contractor shall provide finish selections to the Government Representative, or the Government will provide selection to the contractor.EAF&I40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
51.0Paint door frame flat, semi-gloss, or high gloss. The cost shall be per side (if two sides are required the cost will double). The contractor shall provide finish selections to the Government Representative, or the Government will provide selection to the contractor.EAF&I40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
52.0Paint or varnish any type of trim two coats. The contractor shall provide finish selections to the Government Representative, or the Government will provide selection to the contractor.LFF&I100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
53.0Paint or varnish radiator cabinet or fan coil unit (wood or metal units) with one coat primer and two finish coats. Including surface preparation sanding, scraping, etc. The cost will be determined by the square feet of the front view. The contractor shall provide finish selections to the Government Representative, or the Government will provide selection to the contractor.SFF&I100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
54.0Electrostatic paint any metal surface (linear diffuser, toilet partition, etc.), including all preparation, cleaning, sanding, etc. of the surface.SFF&I100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
55.0Paint window sash, frame, etc. one coat primer and two coats finish coats wood or metal, including surface Preparation sanding, scraping, etc. The cost will be Determined by the square feet of the front view.SFF&I100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
56.0Install Government furnished wall covering, vinyl or fabric. Including wall preparation sizing, primer, sanding, etc. The Contractor shall supply all other necessary materials (adhesive, etc.).SFF&I1250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
57.0Skim coating of existing wall or ceiling surface (drywall, CMU, etc.).SFF&I1250.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
58.0Install Government furnished bookcases and provide all necessary trim or molding to complete the installation, including touch- up bookcases as required. Price shall be determined by the square feet face or front view of bookcase.SFF&I600.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
59.0Furnish and install ¾" thick fire retardant plywood required for electrical panel board and telephone equipment including two coats of paint.SFF&I500.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
60.0Transport and reassemble furniture cubicle including all parts from building storage area to office assemble area as designated by Government. Price determined by square footage of cubicle.LFF&I1750.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
61.0Relocate existing thermostat electric or pneumatic, including all necessary wiring and piping.EASP20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
62.0Relocate existing sprinkler head and F.I.T. fitting, replace plain end fitting to match existing, including all necessary piping required for relocation. Also including replacement of ceiling tile if necessary.EASP60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
63.0Furnish and install sprinkler head and all new components to match the building, including all necessary piping required for installation.EASP40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
64.0Relocate existing fire bell, pull station, supervision sprinkler device, speaker, including any wiring, conduit, etc. necessary for relocation. Also including patching and painting of existing location, or furnish and install blank cover as indicated on the order.EASP40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
65.0Furnish and install copper piping or tubing, type "L", ½" or ¾" including all hangers, supports, anchors, fittings, sweating of joints, etc.LFM80.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
66.0Furnish and install copper piping or tubing, type "L", 1" or 1¼" including all hangers, supports, anchors, fittings, sweating of joints, etc.LFM60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
67.0Furnish and install copper piping or tubing, type "L", 1½" to 2" including all hangers, supports, anchors, fittings, sweating of joints, etc.LFM40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
68.0Furnish and install ball or gate valve ½" or ¾" bronze body, including all necessary fittings, sweating of joints, etc.EAM40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
69.0Furnish and install ball or gate valve 1" or 1¼" bronze body, including all necessary fittings, sweating of joints, etc.EAM30.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
70.0Furnish and install ball or gate valve 1½" to 2" bronze body, including all necessary fittings, sweating of joints, etc.EAM20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
71.0Furnish and install "No-Hub" cast iron waste line up to 4" including all necessary hangers, supports, anchors, fittings, etc.LFM40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
72.0Furnish and install piping insulation (1" wall fiberglass with all service jacket or ½" wall flexible closed cell foam rubber) for up to 2" piping as per the order.LFM100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
73.0Furnish and install 24" x 24" lay-in type ceiling grid mounted diffuser (T Bar, Round or Perforated) with 8" - 12" diameter neck and round butterfly damper including up to 15'-0" linear feet of insulated flexible duct, spin-in collar, nylon ties and connection into existing air supply duct. Diffuser to match or equal to existing building standard.EAM200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
74.0Furnish and install 24" x 24" lay-in type ceiling grid mounted plenum air return grille (T Bar, Round, Eggcrate or Perforated type). Grille to match or equal to existing building standard.EAM200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
75.0Furnish and install variable volume or constant volume mixing boxes with electric motor, pneumatic motor or pressure independent box including hangers and supports. Mixing box to match or equal to existing building standard.EAM40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
76.0Rezone existing light fixture, light to be put on another circuit. Cost determined as one rezone per four fixtures. Rezoning light includes disconnecting and reconnecting of wiring and conduit.EAE160.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
77.0Relocate existing electrical wall outlet, switch, and power pole, including all necessary wiring and conduit. Also including patching and painting of existing location, or furnish and install blank cover as indicated on the order.EAE60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
78.0Relocate existing telephone wall outlet, including all necessary wiring and conduit. Also including patching and painting of existing location, or furnish and install blank cover as indicated on the order.EAE60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
79.0Relocate existing light fixture, emergency light, and exit light, including patching and painting of existing location, or furnish and install blank cover as indicated on the order.EAE40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
80.0Relocate floor service modules. Line item is for 5000 Wissahickon Ave. Bldg.EAE40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
81.0Furnish and install power pole or system furniture power feed whip (base or top feed). Connect equipment to building power system per specified wiring requirements.EAE20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
82.0Furnish and install electrical wall switch (single pole, three way or four way) as required using a multi conductor MC Cable. All circuits shall be labeled on the panel board, outlet, and print.EAE40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
83.0Furnish and install motion sensor manufacturer and model number to match building standard including up to 50'-0" of wiring.EAE20.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
84.0Furnish and install electrical wall circuits for system furniture (one dedicated and two general use circuits) complete with box and cover plate, etc. All circuits shall be labeled on the panel board, outlet, and print. All wiring in the electrical closet shall be in EMT.EAE80.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
85.0Furnish and install electrical (general use or dedicated) duplex wall outlet 20 or 30 amp, 120, 208, or 220 volts. Connect to power source as directed using MC Cable up to 50'-0" of wiring. All circuits shall be labeled on the panel board, outlet, and print. All wiring in the electrical closet shall be in EMT.EAE160.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
86.0Furnish and install floor electrical (general use or dedicated) duplex floor outlet 20 or 30 amp, 120, 208, or 220 volts. Connect to power source as directed using MC Cable up to 50'-0" of wiring. All circuits shall be labeled on the panel board, outlet, and print.EAE80.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
87.0Furnish and install floor telephone or data outlet, flush brass, polycarbonate, or pedestal aluminum, including a pull string.EAE60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
88.0Furnish and install plug and concrete patch for floor outlet hole. Concrete shall be flush with the existing floor slab.EAE40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
89.0Furnish and install telephone or data wall outlet box with ½" grommet hole blank plate in the wall and extend ¾" EMT conduit or greenfield per the order to an accessible ceiling location and provide pull string.EAE120.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
90.0Remove and reinstall carpet to gain access into the floor duct system for the installation of electrical and telephone floor outlets, (cost will be determined per linear foot of carpet removed).LFE160.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
91.0Furnish and install circuit breaker panel board three phase five wire 120/208 volt or 120/240 volt 225amp, main lug, 42 circuit with one, two, and/or three pole bolt in breakers, as requested by the Government, including disconnect switch, conduit and wire up to 50'-0", etc. All wiring in the electrical closet shall be in EMT.EAE10.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
92.0Furnish and install 1'-0" x 4'-0", 2'-0" x 2'-0", or 2'-0" x 4'-0", metric equivalent, recessed air handling, troffer deep cell (18) parabolic or prismatic lens, silver reflector, energy saving electronic ballast (dimming ballast per order) and lamps (F32T8 - 2700K to 4100K, 120 or 277 volts). Provide two, three, or four tubes fixture as requested on the order.EAE160.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
93.0Furnish and install high-hat light fixture parabolic or prismatic lens, Alzak finish, energy saving electronic ballast (single or double ballast) 120 volt or 277 volt 2-26 watt compact fluorescent as per the order.EAE60.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
94.0Remove and replace existing ballast in the existing troffer (120 volt or 277 volt). Replace ballasts in kind or provide energy savings electronic ballast and relamp fixture as per GSA recommendation.EAE200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
95.0Remove, wipe, clean, and relamp existing troffer and provide 1, 2, 3, or 4 lamps as per order.EAE400.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
96.0Furnish and install MC Cable three wire, #12 THNN.LFE500.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
97.0Furnish and install conductor, single copper, #12 or #10 AWG, THHN or THWN.LFE400.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
98.0Furnish and install CAT-6 cable including all connectors, termination points, hangers, supports, etc.LFE500.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
99.0Furnish and install, 4 to 8 conductor telephone cable including all connectors, termination points, hangers, supports, etc.LFE500.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
100.0Furnish and install conduit (EMT or Wiremold) ¾" or 1" including all necessary fittings, field bends, hangers, anchors, pull string, etc.LFE200.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
101.0Provide and connect electrical power, telephone, data, and CAT-6 cable to system furniture cubicle including cabling and wiring up to 75'-0".EAE40.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
102.0Provide an Asbestos Building Inspector, with EPA accreditation training certification and any specific state and/or local licensing required, to perform an asbestos pre-alteration assessment which meets the requirements of a pre-construction survey and provide a report per ASTM E2356-10. Proof of qualifications shall be provided to GSA upon request. Provide all equipment necessary to perform the assessment. Restore destructive sample locations to match their original condition where possible. In addition to the report, submit the survey data electronically in the format of the excel file (asbestos surveys upload template - blank) provided as Attachment with 1 row per homogeneous area (HA) per floor per location. Additional instructions for populating the excel file are provided in AttachmentDailySP30.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
103.0Provide bulk sample analysis by Polarized Light MicroscopyEASP100.0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
Yearly Subtotal:$ - 0$ - 0$ - 0$ - 0$ - 0
Division Key:Total Evaluated Price:
DDemolition Line Items$ - 0
F&IFurnish and Install Line Items
SPSpecialty Line Items
MMechanical Line Items
EElectrical Line Items
Units Key:
SFSquare Feet
SYSquare Yards
LFLinear Feet
EAEach

Sheet2

Sheet3

File details come from the government source that posted it. Updated .