BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-1
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
ATTACHMENT JA3
Barksdale AFB Water Distribution System
Table of Contents
JA3 BARKSDALE AFB WATER DISTRIBUTION SYSTEM ............................................ JA3-2
JA3.1 BARKSDALE AFB OVERVIEW .......................................................................................... JA3-2 JA3.2 WATER DISTRIBUTION SYSTEM DESCRIPTION ............................................................... JA3-2
JA3.2.1 Water Distribution System Fixed Equipment Inventory .......................................... JA3-2 JA3.2.2 Water Distribution System Non-Fixed Equipment and Specialized Tools ............... JA3-8 JA3.2.3 Water Distribution System Manuals, Drawings, and Records ................................. JA3-9
JA3.3 SPECIFIC SERVICE REQUIREMENTS ................................................................................. JA3-9 JA3.4 CURRENT SERVICE ARRANGEMENT ............................................................................. JA3-10 JA3.5 METERING ...................................................................................................................... JA3-10
JA3.5.1 Existing Meters ........................................................................................................ JA3-10 JA3.5.2 Required New Meters ............................................................................................... JA3-11
JA3.6 MONTHLY SUBMITTALS ................................................................................................ JA3-11 JA3.7 WATER CONSERVATION PROJECTS .............................................................................. JA3-12 JA3.8 SERVICE AREA ................................................................................................................ JA3-12 JA3.9 OFF-INSTALLATION SITES ............................................................................................. JA3-12 JA3.10 SPECIFIC TRANSITION REQUIREMENTS ...................................................................... JA3-12 JA3.11 INITIAL SYSTEM DEFICIENCY CORRECTIONS (ISDC) ................................................ JA3-13 JA3.12 RIGHT OF ACCESS TO THE UTILITY SYSTEM ............................................................... JA3-13
JA3.12.1 Map of the Utility System ...................................................................................... JA3-13 JA3.12.2 Lateral Extent of the Right-of-Access, and Points of Demarcation ....................... JA3-13 JA3.12.3 Environmental Baseline Survey ............................................................................. JA3-19
LIST OF TABLES
TABLE 1 - FIXED INVENTORY ......................................................................................................... JA3-5 TABLE 2 - SPARE PARTS ................................................................................................................. JA3-9 TABLE 3 - SPECIALIZED VEHICLES AND TOOLS ............................................................................ JA3-9 TABLE 4 - MANUALS, DRAWINGS, AND RECORDS ...................................................................... JA3-9 TABLE 5 - EXISTING METERS........................................................................................................ JA3-10 TABLE 6 - REQUIRED NEW METERS ............................................................................................ JA3-11 TABLE 7 - WATER CONSERVATION PROJECTS ............................................................................ JA3-12 TABLE 8 - SERVICE CONNECTIONS AND DISCONNECTIONS ..................................................... JA3-12 TABLE 9 - INITIAL SYSTEM DEFICIENCY CORRECTIONS ............................................................ JA3-13 TABLE 10 - STANDARD POINTS OF DEMARCATION ................................................................... JA3-14 TABLE 11 - UNIQUE POINTS OF DEMARCATION ........................................................................ JA3-16
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-2
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
JA3 Barksdale AFB Water Distribution System
JA3.1 Barksdale AFB Overview
Barksdale Air Force Base is located in the northwest portion of Louisiana, within the Shreveport-Bossier City Metropolitan Statistical Area (MSA). Accessible by I-20 (east-west) and I-49 (north-south), Barksdale AFB is approximately 180 miles east of Dallas and 312 miles northwest of New Orleans. Occupying nearly 22,000 acres of land, the Base is bounded by Louisiana Highway 71 on the west and U.S. Highway I-20 on the north.
Barksdale AFB is hosted by the 2d Bomb Wing and is currently home for a number of active duty and reserve component units, including Headquarters Eighth Air Force and the 917th Wing (Air Force Reserve Wing). Units within the 2d Bomb Wing include the 2d Operations
Group, the 2d Logistics Group, the 2d Support Group, and the 2d Medical Group.
Construction of the airfield began in 1931. Barksdale Field was formally dedicated on February 2, 1933, marking the culmination of concerted community action to bring the airfield to the Shreveport area. Weeklong activities in February 1993 marked the 60th anniversary of Barksdale AFB. This celebration included the acceptance of a National Registry of Historic Places certificate placing 264 buildings constructed between 1930 and 1938 in the Barksdale Field Historic District.
The current mission of the 2d Bomb Wing is to develop and maintain operational capability to conduct strategic warfare as an Air Force Global Strike Command Base. The primary assets of the Wing are three active Bomb Squadrons, each composed of B-52H bombers. The 2d Bomb Wing provides global combat capability and trains all B-52 combat crews.
The 917th Wing is a composite wing that operates and maintains both the A-10 Thunderbolt and the B-52H Stratofortress.
The addition of the B-52H to the 917th Wing and the removal of the KC-10 and KC-135 aerial refueling aircraft in 1994 have resulted in a number of changes in the maintenance facilities. On-going projects have focused on consolidating functions and expanding those facilities used by the 917th Wing. There are no other known new missions or planned changes that would significantly affect the current operations, support, personnel, or utility functions at Barksdale AFB.
As of June 2007, the population of Barksdale AFB included approximately 7,306 active and reserve military personnel as well as approximately 1,859 civilian employees.
JA3.2 Water Distribution System Description
JA3.2.1 Water Distribution System Fixed Equipment Inventory
The Barksdale AFB water distribution system consists of all appurtenances physically connected to the distribution system from the point of demarcation defined by the Right of Access. The distribution system consists of the items listed in Table 1 “Fixed Inventory Water Distribution System” in Section JA3. 2.1.2 Inventory. The actual inventory of items
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-3
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10 sold will be in the bill of sale at the time the system is transferred. The following description and inventory is included to provide the Offeror with a general understanding of the size and configuration of the distribution system. The Government makes no representation that the inventory is accurate. The Offeror shall base its proposal on the Table 1 inventory below.
However, the Offeror should use the following reference points for developing other aspects of its proposal: site inspections, information in the technical library, and other pertinent information.
Specifically excluded from the water distribution system privatization are:
Irrigation systems
Non-potable fire systems
Backflow prevention devices located inside existing facilities
SCADA or EMCS communication systems
Water storage tank telemetry systems
Flight Line
Military Family Housing (MFH)
Weapons Storage Area (WSA)
Family Campground
Clear Lake Park
Clairborne Air Force Range
Meters connected to Barksdale AFB Local Area Network (LAN)
JA3.2.1.1 Description
The water distribution system receives treated surface water from the Shreveport’s Amiss Water Treatment Plant (WTP). Water is distributed through mains, laterals, storage tanks, and is treated seasonally at two disinfectant booster stations. Water is supplied to the base fully treated with chloramine disinfectant residual and fluoridation. The water is conveyed through piping ranging in size from 2 inches to 16 inches, primarily comprised of PVC. The vast majority of the mains are polyvinyl chloride (PVC) pipe installed in the last 15 years.
The average depth of burial for the potable water system piping is four feet. Marker tape has been included within the system.
Potable water for the base is supplied through a City of Shreveport owned single 16 inch water main from the Amiss Water Treatment Plant (WTP) in nearby Shreveport, Louisiana.
This connection serves as the primary supply for all facilities within the installation perimeter. Pressure is typically between 60 PSIG to 100 PSIG at the North Gate meter point.
Total water usage is metered adjacent to the North Gate. For approximately one week per year, when Shreveport is unable to provide service, the base relies on the Bossier City WTP
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-4
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10 as a back-up water supply. The Bossier City owned 12 inch primary pipe connection is located at the West Gate. The connection to Bossier City must be operated manually.
Fiscal year (FY) 2009 data identifies that potable water consumption averages 17.0 million gallons (MG) per month. In order to maintain potable water standards, the base utilizes eight flush points throughout the base and has added automatic flushers at dead end locations. In warmer months, two booster stations provide added disinfectant to ensure a safe supply.
The two chloramines booster stations are used to augment disinfectant residual concentrations during the summer. The booster stations are not utilized during the entire year. Chlorine gas and ammonia gas are combined and injected into the source water pipeline at each booster station. Both chemicals are maintained in 150-lb gas cylinders. An audible and visual alarm consisting of a flashing light and siren is present at the North Gate disinfectant booster station. All chlorine and ammonia tanks currently have automatic shutoff valves that respond to sudden changes in chemical feed line pressure.
The majority of the drinking water system is operated manually, with the exception of two storage tanks that have telemetry associated with tracking high and low levels. Manually operated elements include filling the other four storage tanks, and treatment chemical dosing rates, which are set according to sampling results.
There are three privatized housing areas to which the Base supplies water. Historic District Housing is located northwest of the Flight Line and is tied into the central base water distribution system. Capehart Housing and Heritage Heights Housing are located on the eastside of the base and are supplied potable water via a ten inch PVC pipe.
Note: The above quantities include Military Family Housing (MFH), Weapons Storage Area (WSA) and the Flight Line as well as Main Base. The quantities in the below inventory reflect the Main Base, not including the already privatized MFH, and inventory outside the restricted areas of the WSA and Flight Line.
JA3.2.1.2 Inventory
Table 1 provides a general list of the major water distribution system fixed assets for the Barksdale AFB water distribution system included in the sale. The design life column indicated in Table 1 is used by the Government in the development of the Government Should Cost Estimate. The design life is not mandated in the Offeror’s proposal. However, the proposal must clearly explain the use of any system component design life that significantly differs from the published Government design life.
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-5
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 1
Fixed Inventory Water Distribution System
Item Size Quantity Unit Approximate Year of
Construction
Design Life (Years)
Water Distribution Pipe
Water Pipe, DI 16” 327 LF 2003 75
Water Pipe, PVC 2” 880 LF 1995 50
Water Pipe, PVC 2” 1791 LF 2008 50
Water Pipe, PVC 4” 1633 LF 1995 50
Water Pipe, PVC 4” 1871 LF 1999 50
Water Pipe, PVC 4” 3126 LF 2008 50
Water Pipe, PVC 6” 12120 LF 1995 50
Water Pipe, PVC 6” 11608 LF 1999 50
Water Pipe, PVC 6” 9655 LF 2003 50
Water Pipe, PVC 6” 8901 LF 2008 50
Water Pipe, PVC 8” 39574 LF 1995 50
Water Pipe, PVC 8” 12162 LF 1999 50
Water Pipe, PVC 8” 2487 LF 2003 50
Water Pipe, PVC 8” 20201 LF 2008 50
Water Pipe, PVC 10” 991 LF 1995 50
Water Pipe, PVC 10” 10738 LF 1999 50
Water Pipe, PVC 10” 30443 LF 2008 50
Water Pipe, PVC 12” 1268 LF 1995 50
Water Pipe, PVC 12” 8431 LF 1999 50
Water Pipe, PVC 12” 3336 LF 2003 50
Water Pipe, PVC 12” 17546 LF 2008 50
Water Pipe, PVC 14” 3192 LF 2003 50
Water Pipe, PVC 14” 196 LF 2008 50
Water Pipe, PVC 16” 2579 LF 2003 50
Fire Hydrant
Fire Hydrant Assembly, 4.5 feet deep 4.5" 14 EA 1995 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 5 EA 1996 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 15 EA 1998 25
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-6
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 1
Fixed Inventory Water Distribution System
Item Size Quantity Unit Approximate Year of
Construction
Design Life (Years)
Fire Hydrant Assembly, 4.5 feet deep 4.5" 21 EA 1999 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 6 EA 2000 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 11 EA 2001 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 12 EA 2002 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 37 EA 2003 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 32 EA 2004 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 15 EA 2005 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 14 EA 2006 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 5 EA 2007 25
Fire Hydrant Assembly, 4.5 feet deep 4.5" 16 EA 2008 25
Water Isolation Valve
Water Valve, Ball 2” 5 EA 1995 25
Water Valve, Ball 2” 8 EA 1999 25
Water Valve, Ball 2” 20 EA 2003 25
Water Valve, Ball 2” 82 EA 2008 25
Water Valve, Ball 2.5” 2 EA 2008 25
Water Valve, Gate 4” 3 EA 1995 25
Water Valve, Gate 4” 9 EA 1999 25
Water Valve, Gate 4” 14 EA 2003 25
Water Valve, Gate 4” 46 EA 2008 25
Water Valve, Gate 6” 22 EA 1995 25
Water Valve, Gate 6” 21 EA 1999 25
Water Valve, Gate 6” 43 EA 2003 25
Water Valve, Gate 6” 65 EA 2008 25
Water Valve, Gate 8” 6 EA 1995 25
Water Valve, Gate 8” 18 EA 1999 25
Water Valve, Gate 8” 49 EA 2003 25
Water Valve, Gate 8” 94 EA 2008 25
Water Valve, Gate 10” 9 EA 1999 25
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-7
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 1
Fixed Inventory Water Distribution System
Item Size Quantity Unit Approximate Year of
Construction
Design Life (Years)
Water Valve, Gate 10” 4 EA 2003 25
Water Valve, Gate 10” 8 EA 2008 25
Water Valve, Gate 12” 1 EA 1999 25
Water Valve, Gate 12” 8 EA 2003 25
Water Valve, Gate 12” 10 EA 2008 25
Water Valve, Post Indicator 4" - 14" 2 EA 1995 35
Water Valve, Post Indicator 4" - 14" 11 EA 1999 35
Water Valve, Post Indicator 4" - 14" 15 EA 2003 35
Water Valve, Post Indicator 4" - 14" 30 EA 2008 35
Backflow Prevention Devices
Backflow Prevention Device 2” 4 EA 1995 10
Backflow Prevention Device 2” 2 EA 2003 10
Backflow Prevention Device 4” 5 EA 1995 10
Backflow Prevention Device 4” 4 EA 2003 10
Backflow Prevention Device 6” 3 EA 1995 10
Backflow Prevention Device 6” 4 EA 2003 10
Backflow Prevention Device 8” 2 EA 1995 10
Backflow Prevention Device 8” 1 EA 2003 10
Backflow Prevention Device 10” 1 EA 1995 10
Backflow Prevention Device 10” 1 EA 2003 10
Water Supply Meters
Water Supply Meter, Turbine 4" 3 EA 1991 25
Water Supply Meter, Turbine 4" 3 EA 1993 25
Water Supply Meter, Turbine 4" 3 EA 1995 25
Water Supply Meter, Turbine 4" 3 EA 2000 25
Water Supply Meter, Turbine 4" 3 EA 2005 25
North Gate Water Supply Building
Chlorination Facility N/A 250 SF 1970 50
Chlorination Equipment N/A 1 EA 2000 20
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-8
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 1
Fixed Inventory Water Distribution System
Item Size Quantity Unit Approximate Year of
Construction
Design Life (Years)
Water Meter Vault 6’x6’x10’ 1 EA 1970 60
Water Storage Tank, Shreveport Gate #1358
Elevated Water Storage Tank, Steel 500 Kgal 1 EA 1942 75
Potable Water Building #1357 N/A 750 SF 1994 50
Pressure Booster Pump, 1,500 GPM 60 HP 2 EA 1994 30
Water Pipe, DI 10” 75 LF 1994 75
Water Valve, Gate 10” 9 EA 1994 25
Water Valve, Butterfly 10” 1 EA 1994 25
Water Storage Tank, Supply Tower #4490
Elevated Water Storage Tank, Steel 500 Kgal 1 EA 1994 75
Potable Water Building #4491 N/A 750 SF 1994 50
Chlorination Facility N/A 250 SF 1994 50
Chlorination Equipment N/A 1 EA 1994 20
Pressure Booster Pump, 1,500 GPM 60 HP 2 EA 1994 30
Water Pipe, DI 10” 75 LF 1994 75
Water Valve, Gate 10” 9 EA 1994 25
Water Valve, Butterfly 10” 1 EA 1994 25
Water Storage Tank, Bossier Base #7291
Elevated Water Storage Tank, Steel 75 Kgal 1 EA 1951 75
Water Pipe, DI 10” 50 LF 1994 75
Water Valve, Gate 10” 4 EA 1994 25
Notes:
PVC = Polyvinyl chloride SF = square feet ea = each KGal = kilogallons gal= gallon DI = Ductile iron hp = horsepower N/A = Not applicable lf = linear feet
JA3.2.2 Water Distribution System Non-Fixed Equipment and Specialized Tools
Table 2 lists other ancillary equipment (spare parts) and Table 3 lists specialized vehicles and tools included in the purchase. Offeror shall field verify all equipment, vehicles, and tools prior to submitting a bid. Offeror shall make its own determination of the adequacy of all equipment, vehicles, and tools.
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-9
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 2
Spare Parts Water Distribution System
Item Make/Model Description Quantity Remarks
None
TABLE 3
Specialized Vehicles and Tools Water Distribution System
Item Make/Model Description Quantity Remarks
None
JA3.2.3 Water Distribution System Manuals, Drawings, and Records
Table 4 lists the manuals, drawings, and records that will be transferred with the system.
TABLE 4
Manuals, Drawings, and Records Water Distribution System
Item Description Quantity Remarks
Utility Drawings GIS Data, Auto CAD G tabs Various ---
AF 7115 Real Property Records 1 Dated: February 2010
AF 3556 Utility Sales Rates Consumption 1 Dated: November 2009
Barksdale AFB Housing eEasements
GIS document showing locations of Housing GIS Coordinates as shown in Table 11, below.
1 Current Version to be provided to SO
JA3.3 Specific Service Requirements
Service requirements for this water distribution system are as defined in the RFP Section C, Description/Specifications/Work Statement. The following requirements are specific to the base water distribution system and are in addition to those found in Section C.
1. The SO shall perform flow testing and marking of fire hydrants IAW National Fire Protection Association standards/recommended practices. The government reserves the right to review flow test records. The SO shall be required to meet all unique and specific fire-flow requirements for the base, which will be listed and available in the Utilities Privatization Technical Library.
2. The Government will provide the electricity, natural gas, and water commodities and the wastewater collection required to operate and maintain the systems being privatized at no cost to the System Owner (SO). The Government will also provide
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-10
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10 any infrastructure necessary to connect the facilities required to operate and maintain the systems being privatized to electricity, natural gas, water, and wastewater collection services at no cost to the SO. If fuel oil or propane is required to operate emergency generators, purchase and supply of that fuel oil or propane will be the responsibility of the SO.
3. The Government will retain ownership of Airfield Beacon(s), communication equipment, associated wiring, and ancillary equipment attached to the water system.
The SO will always allow the government, or its agent, full and unrestricted access to these items.
JA3.4 Current Service Arrangement
Potable water from the City of Shreveport’s Amiss Water Treatment Plant (WTP) plant is conveyed to Shreveport’s McNeil Pumping Station and its 3.0 MG clear well. From this point, water is conveyed to the base via a City of Shreveport owned 16” supply main at a pressure of approximately 70 pounds per square inch (psi). When the Amiss WTP is offline for approximately one week each year, water is supplied through a Bossier City owned 12” main from the Bossier City WTP. The connection to Bossier City must be operated manually, and serves as a backup potable water supply. Per the Air Force Form 3556, dated November 2009, FY2009 annual potable water consumption was approximately 204,054 kGal.
In warmer months, two Barksdale AFB owned booster stations provide added disinfectant to ensure a safe supply.
JA3.5 Metering
JA3.5.1 Existing Meters
Table 5 provides a list of the existing (at the time of contract award) meters that will be transferred to the SO. The SO shall provide monthly meter readings for all meters listed below.
TABLE 5
Existing Meters Water Distribution System
Meter Location Meter Size Remarks
Bldg. 2151 - 201 Ira Eaker (front) 4 inch ------
Bldg. 2151 - 201 Ira Eaker (back) 4 inch ------
Bldg. 2665 - 205 Hap Arnold 4 inch ------
Bldg. 2777 - 305 Hap Arnold 4 inch ------
Bldg. 4666 - Dental Clinic 4 inch ------
Bldg. 3900 - Auto Pride 4 inch ------
Bldg. 4125 - Veterinary Clinic 4 inch ------
Bldg. 4250 - Burger King 4 inch ------
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-11
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 5
Existing Meters Water Distribution System
Meter Location Meter Size Remarks
Bldg. 4265 - Base Exchange 4 inch ------
Bldg. 4549 - Managed Care 4 inch ------
Bldg. 4765 - Commissary 4 inch ------
Bldg. 5435 – Chase Bank 4 inch ------
Bldg. 5456 - B-Xtra 4 inch ------
Bldg. 8929 - Capehart Shopette 4 inch ------
Bldg. 4523 - Barksdale Clinic 4 inch ------
Note: No meters owned by SO are to be connected to the Barksdale AFB LAN
JA3.5.2 Required New Meters
The SO shall install and calibrate new meters as listed in Table 6.
TABLE 6
Required New Meters Water Distribution System
Meter Location Meter Size Remarks
Note: No meters owned by SO are to be connected to the Barksdale AFB LAN
JA3.6 Monthly Submittals
The SO shall provide the Government with monthly submittals for the following:
1. Outage Report. The SO’s monthly outage report will be prepared in the format proposed by the SO and accepted by the Contracting Officer. Outage reports shall be submitted by the 25th of each month for the previous month. Outage reports shall be submitted to:
Organization/Office Symbol: 2 CES/CECN Address: 334 Davis Ave. W. #200 Barksdale AFB, LA 71110-2078
Phone number: 318-456-3076
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-12
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
2. Meter Reading Report. The monthly meter reading report shall show the current and previous month readings for all meters. The SO’s monthly meter reading report will be prepared in the format proposed by the SO and accepted by the Contracting Officer. Meter reading reports shall be submitted by the 15th of each month for the previous month. Meter reading reports shall be submitted to:
Organization/Office Symbol: 2 CES/CECN Address: 334 Davis Ave. W. #200 Barksdale AFB, LA 71110-2078
Phone number: 318-456-3076
JA3.7 Water Conservation Projects
The following projects listed in Table 7 have been implemented by the Government for water conservation purposes.
TABLE 7
Water Conservation Projects Water Distribution System
Project Location Project Description
JA3.8 Service Area
The current service area is defined as all areas within the Barksdale AFB boundaries, except as specifically excluded in Section JA3.2.1.
JA3.9 Off-Installation Sites
No off-installation sites are included in the sale of the Barksdale AFB water distribution system.
JA3.10 Specific Transition Requirements
Table 8 provides a list of service connections and disconnections required upon transfer.
TABLE 8
Service Connections and Disconnections Water Distribution System
Location Description
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-13
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
JA3.11 Initial System Deficiency Corrections (ISDC)
Table 9 provides a list of ISDC projects the Government has planned for this system. The Government recognizes these projects represent current deficiencies associated with the system. If the system is sold, the Government will not accomplish these projects. The SO shall determine the actual need and timing of any and all such projects.
TABLE 9
Initial System Deficiency Corrections Water Distribution System
Project Location Project Description
None
JA3.12 Right of Access to the Utility System
No leased property was identified with the Water Distribution system.
JA3.12.1 Map of the Utility System
Maps from the Base Comprehensive Plan or other drawings show the known locations of the utility system and are available in the technical library at the base civil engineer organization. Portions of the utility system may not be fully shown on the map or maps.
Any such failure to show the complete utility system on the map or maps shall not be interpreted as that part of the utility system being outside the Installation. The Installation is co-extensive with the entire linear extent of the utility system sold to Grantee (SO), whether or not precisely shown on the map or maps.
JA3.12.2 Lateral Extent of the Right-of-Access, and Points of Demarcation
JA3.12.2.1 Lateral Extent of Utility System Right-of-Access
For pipe sizes of 24 inches in diameter or less, the lateral extent of the Right-of-Access is defined as 26-feet wide, extending 13 feet on each side of the utility system, as installed.
For pipe sizes greater than 24 inches in diameter, the lateral extent of the Right-of-Access is defined as 50-feet wide, extending 25 feet on each side of the utility system, as installed.
JA3.12.2.2 Utility System Points of Demarcation
The point of demarcation (POD) is defined as the point on the utility system where ownership changes from the utility SO to the facility owner. Table 10 identifies the type and general location of the point of demarcation with respect to the facility for each scenario.
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-14
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 10
Standard Points of Demarcation Water Distribution System
Point of Demarcation Applicable Scenario Sketch
POD is on the downstream side of the water meter, backflow device, or valve that is closest to the structure.
Water meter, backflow device, or valve is located on the service line within 25 feet of the exterior of the structure.
POD is where the service line enters the structure.
Water meter, backflow device, or valve is not located on the service line within 25 feet of the exterior of the structure.
Note: Meter, backflow device, or valve may be installed within 25 feet of the structure at any time. When installed, the downstream side of the meter, backflow device, or valve will become the new point of demarcation.
If the fire suppression system has a storage tank, the POD is the upstream side of the isolation valve or backflow prevention device closest to the storage tank.
If the fire suppression system does not have a storage tank, the POD is the upstream side of the PIV or isolation valve closest to the fire suppression pumps.
Fire suppression system is provided flow and/or pressure by the potable water distribution system. These systems are typically dedicated to serving one facility or a small cluster of facilities.
POD is the upstream side of the PIV, isolation valve, or backflow prevention device closest to the fire suppression system.
Fire suppression system is connected to the potable water distribution system.
POD for irrigation systems is the upstream side of the backflow prevention device or isolation valve closest to the irrigation system.
Irrigation system is fed directly from potable water distribution system.
Structure
Service Line
Point of Demarcation
Distribution Main
Structure
Service Line
Distribution Pipe
Water Meter
Distribution Pipe
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-15
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 10
Standard Points of Demarcation Water Distribution System
Point of Demarcation Applicable Scenario Sketch
POD is the upstream side of the hose bib or drinking fountain.
Note: A service valve may be installed within 25 feet of the hose bib or drinking fountain at any time. Once installed, the inlet side of the service valve becomes the new POD.
Hose bibs and drinking fountains connected to the water distribution system (typically found at ball fields and outdoor recreation areas).
Service valve is not located within 25 feet of these devices on the lateral that services these devices.
POD is the inlet side of the service valve.
Hose bibs and drinking fountains connected to the water distribution system (typically found at ball fields and outdoor recreation areas).
Service valve is located within 25 feet of these devices on the lateral that services these devices.
POD is where the overhead conductor is connected to the service entrance mast.
Note: If an electric meter is present, or is to be installed, the owner of the electric distribution system on the installation is the owner and maintainer of the electric meter and the can, regardless of their location. The water utility owner owns the service entrance mast and all wiring on the load side of the
POD.
Electric power is provided to a water facility via an overhead service drop.
This configuration could be found at facilities dedicated to the water utility such as a water well, pump station, or storage facility.
POD is at the secondary terminal of the transformer.
Note: If an electric meter is present, or is to be installed, the owner of the electric distribution system on the installation is the owner and maintainer of the electric meter and the can, regardless of their location. The water utility owner owns all wiring on the load side of the transformer.
Electric power is provided to a water facility via an underground service connection. This configuration could be found at facilities dedicated to the water utility such as a water well, pump station, or storage facility.
POD is where beacon or communication equipment and/or wire come in physical contact with water system
Airfield beacons and/communication equipment is attached to a water tower
NONE
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-16
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 10
Standard Points of Demarcation Water Distribution System
Point of Demarcation Applicable Scenario Sketch
WITHIN HOUSING AREAS
POD is the upstream side of the meter.
Residential structure.
There is a water meter on the lateral service line.
POD is the downstream side of the shut-off valve.
Residential structure.
There is no water meter on the lateral service line. There is a shut-off valve on the lateral service line.
POD is where the lateral service line connects to the distribution main.
Residential structure.
There is no meter or shut-off valve on the lateral service line.
Table 11 lists anomalous “unique” points of demarcation that do not fit any of the above scenarios. These unique points of demarcation shall take precedence over the standard points of demarcation shown in Table 10.
TABLE 11
Unique Points of Demarcation Water Distribution System
Location POD Description
MSA POD is the downstream side of Regulator Number 01 located West of Ammo Rd.
Flight Line POD is the downstream side of Valve Number 430 located Northwest of Building 7705
Structure
Lateral Service
Line
Point of Demarcation
Distribution Main
Distribution Main
Structure
Lateral Service Line
Shut-off Valve
Distribution Main
Structure
Lateral Service Line
Point of Demarcation
Water Meter
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-17
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 11
Unique Points of Demarcation Water Distribution System
Location POD Description
Flight Line POD is where 3 inch polyethylene main line crosses the North-South security fence line. Fence location is north of Building 6842
Flight Line - Bldg 6850 POD is downstream side of Valve Number 602
Flight Line – Bldg 6836 POD is downstream side of Valve Number 603
Flight Line – Bldg 6830 POD is downstream side of Valve Number 604
Flight Line – Bldg 6826 POD is downstream side of Valve Number 605
Flight Line POD is North side of Valve Number 611, East of Building 6815
Flight Line POD is East side of Valve Number 614
Flight Line POD is West side of Valve Number 624
Flight Line POD is downstream side of Valve Number 623
Flight Line POD is North side of Valve Number 625
Flight Line – Bldg 6448 POD is downstream side of un-numbered valve located South of Bldg 6448
Flight Line – Bldg 6426 POD is downstream side of Valve Number 512
Flight Line – Bldg 6426 POD is downstream side of Valve Number 513
Flight Line – Bldg 6226 POD is downstream side of Valve Number 539
Flight Line – Bldg 6215 POD is downstream side of Valve Number 541
Flight Line – Bldg 6214 POD is downstream side of Valve Number 543
Flight Line – Bldg 6200 POD is downstream side of Valve Number 544
Flight Line POD is where 2 inch polyethylene main line crosses the North-South security fence line located north of Building 6200
Historical West Housing Barksdale AFB side of the POD at GIS Coordinates
435675.883647
3596203.68614
Historical West Housing Barksdale AFB side of the POD at GIS Coordinates
435778.967655
3596260.54265
Historical West Housing Barksdale AFB side of the POD at GIS Coordinates
435863.573775
3596304.84622
Historical West Housing Barksdale AFB side of the POD at GIS Coordinates
435994.571792
3596375.25553
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-18
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 11
Unique Points of Demarcation Water Distribution System
Location POD Description
Historical West Housing Barksdale AFB side of the POD at GIS Coordinates
436141.633492
3596685.32643
Historical West Housing Barksdale AFB side of the POD at GIS Coordinates
436102.627225
3596906.25447
Historical West Housing Barksdale AFB side of the POD at GIS Coordinates
435924.058054
3596890.42592
Historical West Housing Barksdale AFB side of the POD at GIS Coordinates
435907.239689
3596979.5896
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
435747.966345
3596124.59003
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
435751.534334
3596141.22252
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
435900.779623
3596255.55045
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
436081.059308
3596279.45714
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
436363.544808
3596272.8667
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
436538.56521
3596095.50363
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
436602.995663
3595956.9623
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
436576.075036
3595948.3187
BARKSDALE AFB, LA AIR FORCE UTILITIES PRIVATIZATION - REQUEST FOR PROPOSAL (RFP) ATTACHMENT JA3
JA3-19
(Attachment JA3 Water Distribution System Template – SEPTEMBER 2009_REV MAY 2010) User Edited: v06 18Oct10
TABLE 11
Unique Points of Demarcation Water Distribution System
Location POD Description
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
436513.500037
3596004.13934
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
436478.57666
3596021.95781
Historical East Housing Barksdale AFB side of the POD at GIS Coordinates
436345.665477
3596008.7298
Historical East Housing POD is at downstream side of Valve Number MBG102, located East of Building Number 3720
Capehart Housing Barksdale AFB side of the POD at GIS Coordinates
443972.944896
3597748.06458
Capehart Housing Barksdale AFB side of the POD at GIS Coordinates
443954.651969
3597490.01503
Heritage Heights Housing Barksdale AFB side of the POD at GIS Coordinates
444049.978228
33598992.27271
Bossier City Water Supply Main
POD is at downstream side of the Bossier City owned meter located adjacent to Building 1359.
City of Shreveport Water Supply Main
POD is at downstream side of the City of Shreveport owned meter located adjacent to Building 5048.
Note: For ”POD at --- GIS Coordinates” numbering references Base provided GIS document: housing_ eEasements_60x60.pdf
JA3.12.3 Environmental Baseline Survey
The Air Force has determined that it is not required to conduct an EBS in regard to the sale of this utility system.