GRPS Union HS Tremont Blvd Clinic_DRAWINGS.pdf

PDF 9 MB Posted

Attached to
GRPS Innovation Central High Health Clinic Renovations
Solicitation number
RFP-GRP-250000002549-1
Issued by
Kent County, Michigan

About this file

These are architectural and engineering drawings for the Union High School Health Center Renovations project for Grand Rapids Public Schools (GRPS), located at 1800 Tremont Blvd NW in Grand Rapids, Michigan. The comprehensive set of technical drawings includes architectural, mechanical, electrical, and plumbing plans for a 1,957 square foot renovation of an existing school health clinic. The drawings are dated June 2, 2025, and prepared by Architektura PLC, with project number 1342. The documents detail the proposed renovation, which involves reconfiguring existing spaces, installing new casework, updating lighting and electrical systems, and maintaining the existing building's Use Group E classification and Type 3B construction type.

The drawings specify compliance with multiple building codes, including the 2021 Michigan Rehabilitation Code, 2021 Michigan Building Code, 2021 Michigan Commercial Energy Code, and 2023 National Electrical Code. The renovation will preserve the existing building's floor area of 286,000 square feet, with the health center renovation representing approximately 1% of the total area. The project includes maintaining existing fire suppression systems, ensuring accessibility requirements are met, and minimizing changes to the building's core infrastructure. The technical specifications demonstrate a detailed approach to renovation, with careful consideration of existing electrical, mechanical, and plumbing systems, and adherence to state and national building standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ARCHITEKTURA PLC'S LIABILITY IS LIMITED TO THE AMOUNT

OF FEE THAT IS REIMBURSED FOR SERVICES RENDERED ON

THIS PROJECT.

THESE DRAWINGS ARE THE SOLE PROPERTY OF

ARCHITEKTURA PLC AND ARE NOT TO BE USED OR

REPRODUCED WITHOUT THEIR WRITTEN CONSENT.

THIS SEAL APPLIES TO THE FOLLOWING DOCUMENTS SHEET

NUMBER: T1 THRU A-3 ALL DOCUMENTS UNDER THIS STAMP

BEAR THE SAME ISSUE DATE AS THE SEALED COPY.

I HEREBY CERTIFY THAT THESE DRAWINGS WERE

PREPARED UNDER MY DIRECTION AND TO THE BEST OF MY

KNOWLEDGE AND BELIEF, CONFORM TO THE APPLICABLE

CODES AND ORDINANCES.

KIRSTEN A. RUNSCHKE DATE

LICENSE EXPIRES 09-27-2025

PREPARER NOTES:

CONTRACTOR TO CONTACT 811 SERVICE AT LEAST 3 WORKING DAYS PRIOR TO

CONSTRUCTION, TO CONFIRM LOCATION OF EXISTING UTILITIES. DIAL 811. www.CALL811.com

CALL 811

BRIDGE ST NW

TREMONT BLVD NW

C

O V

E L

L A

V E

N W

M T

M

ER

C Y

D R

N W

IR

IS

R D N

W B

E A

U M

O N

T D

R N

W

REBECCA CT NW

45 L E

N O

R A

A V

E N

W

G R

A H

A M

R D

N W

B R

IS

T

O N

A V

E N

W

S

IM

P S

O N

C T

N W

UNION HIGH SCHOOL

T H

IS

D

O C

U M

E N

T H

A S

B E

E N

P R

E P

A R

E D

B Y

A R

C H

IT

E

K T

U R

A P

LC

A

S A

N

IN

S T

R U

M E

N T

O F

S E

R V

IC

E

A

N D

A R

C H

IT

E

K T

U R

A P

L C

S H

A

LL

R E

T A

IN

A

L L

C O

M M

O N

L A

W , S

T A

T U

T O

R Y

A N

D O

T H

E R

R E

S E

R V

E D

R

IG

H T

S , I

N C

LU

D

IN

G

T H

E

C O

P Y

R

IG

H T

T H

E R

E T

O architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

-J un -2

1:

:1

P

M C

:\U se rs \k irs t\O ne D riv e\

D oc um en ts \a rc hi te kt ur a

P

LC

\P ro je ct s\

_G

R P

S U ni on

H ig h S ch oo l H ea lth C en te r\R ev it\ G

R P

S U ni on

H S

T re m on t B lv d C lin ic

_v 3.

rv t

As indicated

T-1

T

IT

L E

D R

A W

IN

G

G R

A N

D R

A P

ID

S

P U

B L

IC

S C

H O

O L

S

U N

IO

N

H S

H E

A L

T H

C E

N T

E R

R E

N O

V A

T

IO

N S

2 JUNE 2025

T

R E

M O

N T

B L V

D N

W

G R

A N

D R

A P

ID

S

M I

GRAND RAPIDS PUBLIC SCHOOLS

UNION HS HEALTH CENTER RENOVATIONS

1800 TREMONT BLVD NW, GRAND RAPIDS MI 49504

BIDS AND PERMITS

DRAWING INDEX

GENERAL

T-1 TITLE DRAWING

G-1 CODE COMPLIANCE PLANS

ARCHITECTURAL

A-1 FIRST FLOOR AND DEMOLITION PLANS, ROOM FINISHES

A-2 FIRST FLOOR REFLECTED CEILING PLAN

A-3 DOOR SCHEDULE, DETAILS, AND ELEVATIONS

MECHANICAL

M-1 FIRST FLOOR AND DEMOLITION PLANS

PLUMBING

P-1 FIRST FLOOR AND DEMOLITION PLANS

ELECTRICAL

E1.00 DETAILS, SYMBOL LENGEDS AND SPECIFICATIONS

E2.00 ONE-LINE DIAGRAM

EL-1 FIRST FLOOR AND DEMOLITION PLANS - LIGHTING

EP-1 FIRST FLOOR AND DEMOLITION PLANS - POWER

3/4" = 1'-0"

SITE

NO. DATE DESCRIPTION

OWNER ARCHITECT MECHANICAL | ELECTRICAL | PLUMBING

WH

CODE SUMMARY

A. APPLICABLE CODES:

1. BUILDING CODES:

A. 2021 MICHIGAN REHABILITATION CODE (MRC)

B. 2021 MICHIGAN BUILDING CODE (MBC)

C. 2021 MICHIGAN COMMERCIAL ENERGY CODE (MCEC)

D. 2017 ICC/ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES

2. MECHANICAL CODES:

A. 2021 MICHIGAN MECHANICAL CODE (MMC)

B. 2021 MICHIGAN PLUMBING CODE (MPC)

3. ELECTRICAL CODE:

A. 2023 NATIONAL ELECTRICAL CODE (NEC)

B. EXISTING AND/OR PROPOSED BUILDING DATA:

1. USE: OFFICE BUILDING, USE GROUP E - NO CHANGE TO EXISTING USE

2. CONSTRUCTION: TYPE 3B - EXISTING TO REMAIN

3. CLASSIFICATION OF WORK: ALTERATION - LEVEL 2 (MRC)

4. BUILDING AREA: NO CHANGE TO EXISTING AREA OR HEIGHT

A. EXISTING FLOOR AREA: 286,000 SF

B. WORK AREA: 1,950 SF

C. CALCULATED PERCENTAGE: 1%

5. AUTOMATIC FIRE SUPPRESSION:

A. FACILITY FULLY SPRINKLERED

B. FIRE EXTINGUISHERS: REQUIRED

C. OCCUPANT LOAD FOR EGRESS PURPOSES:

a. USE AND OCCUPANCY: EXISTING SINGLE-OCCUPANT FACILITY

D. MEANS OF EGRESS REQUIREMENTS:

a. NON-APPLICABLE FOR SINGLE-OCCUPANCY, SINGLE-TENANT STRUCTURE.

b. MAX DEAD END CORRIDOR: 50 FT.

E. ACCESSIBILITY:

1. SCOPE OF ALTERATION SHALL NOT REDUCE THE ACCESSIBILITY OF THE EXISTING

FACILITY

2. ALL WORK IN ALTERED AREA(S) SHALL MEET STATE ACCESSIBILITY REQUIREMENTS

TO THE MAXIMUM AMOUNT FEASIBLE

3. ALTERATION OF AREA(S) CONTAINING PRIMARY FUNCTION:

A. ACCESSIBLE ROUTE TO PRIMARY FUNCTION SHALL BE PROVIDED

B. ACCESSIBLE ROUTE FROM PRIMARY FUNCTION TO TOILET FACILITIES AND

DRINKING FOUNTAINS SHALL BE PROVIDED.

F. PLUMBING FIXTURE REQUIREMENTS:

1. INCREASE IN FLOOR OCCUPANY LOAD < 20%- EXISTING FIXTURES TO REMAIN (MRC)

CODE LEGEND

SMOKE TIGHT WALL CONSTRUCTION

EXIT/EXIT ACCESS WITH CAPACITY SERVED

XXX/XX SF

DIRECTION OF EGRESS INCUDING SECONDARY EXIT/EXIT ACCESS

OCCUPANT LOAD OF SPACE AND BASIS FOR CALCULATION

FIRE EXTINGUISHERFE

EXIT EXIT SIGN AND STROBE

N E

W F

U

LL

L

IT

E D

O O

R N

E W

F U

LL

L

IT

E

D O

O R

FRIDGE

MICRO

WATER

DISP

TS

EXAM

EXAM

EXAMBEHAVIORAL

OFFICE | BREAK

DENTAL

MECH

GRPS OFFICE

RECEPTION

WAITING

TOILET

IT

C O

R R

ID

O

R

CORRIDOR

CAFETERIA

E X

IT

E

X

IT

EXIT

1,950/100 SF

NOTE: AREA OF WORK IN

SCHOOL IS 1,957 SQ FT

FOR HEALTH CLINIC

PACK INSULATION

BETWEEN ADJACENT

BOXES

ACOUSTICAL SEALANTSTEEL STUD

BOX SUPPORT

ELECTRICAL

OUTLET

METAL STUD

FOAMED

INSULATION

AT EXTERIOR

WALLS

NOTES

1. INTENT - ESTABLISHMENT OF COMMON DATUM LINES

THROUGHOUT PROJECT FOR WALL-MOUNTED DEVICES.

2. MASONRY / TILE CONSTRUCTION - ADJUST DEVICES AS

REQUIRED TO INTEGRATE WITH MASONRY / TILE COURSING.

3. METAL STUD CONSTRUCTION - ADJUST DEVICES AS REQUIRED

TO INTEGRATE WITH STUD SPACING.

6" MIN 6" MIN

MISCELLANEOUS DEVICES

MISC. ACCESSORIES

TOILET ROOM ACCESSORIES

PLUMBING FIXTURES

FLOOR MOUNTED W.C.

ACCESSIBLE CLEARANCES

PHONE PUBLIC PAY PHONE

SENSORS:

(TEMPERATURE,

CO2, ETC.)

CONTROLS: (LIGHT

SWITCH, HVAC CONTROL,

FIRE ALARM PULL

STATION, CARD READER,

B.F. DOOR OPENER, ETC.)

WALL DEVICES PROTRUDING

OBJECTS IN

ACCESSIBLE ROUTE

5' TEE

MIN.CLEAR

FLOOR AREA

MIN. CLEAR

FLOOR AREA

ACCESSIBLE CLEAR TURNING AREAS ACCESSIBLE COUNTERTOP

FIRE

EXTINGUISHER

CABINET

C A

B

IN

E T

H A

R D

W A

R E

NO HOOKS

ABOVE B.F.

SHELF UNIT

SHELF AND

COAT RACK

WALL

INSIDE

CORNE

R

PAPER

TOWEL

DISPENSER

SANITARY NAPKIN

AND

TAMPON DISPENSER

PAPER TOWEL

DISPENSER AND

WASTE

RECEPTACLE

HAND DRYER WASTE RECEPTACLE SOAP DISPENSER

H E

IG

H

T S

P E

R A

N S

I A

GRAB BAR SIZE AND

SPACING AT WALL

LAVATORY FRONT ELEVATION LAVATORY SIDE

ELEVATION

C

LE

F

LO

O

R A

R E

A

LAVATORY PLAN

MIN. MIN.

CLEAR FLOOR

AREA

COUNTERTOP SINK

PLAN

GRAB BAR:

COORDINATE HEIGHT WITH

TOILET FLUSH VALVE OR

INFRARED CONTROLLER

WATER CLOSET

STALL FRONT ELEVATION

WATER CLOSET STALL SIDE ELEVATION

TOILET

PARTITION

GRAB

BAR

6". 3' - 0" MIN

2' -9

T

O

C O

N T

R O

L

3'

M A

X

5' - 0" MIN. CLEAR

1' - 0" 3' - 0" 1' - 0"

3'

2'

5' - 0" DIA

6'

M

IN

2'

M

IN

4" MAX.

3"

4" T

O D

E C

K

2'

0"

M A

X

T O

P O

F D

E V

IC

E

4'

C O

IN

S

LO

T

4'

M A

X

4'

M A

X

4'

0"

CLEAR

1' - 6" MIN.

CLEAR

1' - 6" MIN.

3'

T O

P O

F E

S T

IN

G

U

IS

H E

R

5'

M A

X

5'

B A

R R

IE

R

F R

E E

3'

VARIES

1' - 6" O

P E

N

IN

G

C O

N T

R O

LS

4'

2' - 0" MIN.

C O

N T

R O

LS

4'

D

IS

P E

N S

E R

S

LO

T

4'

C O

N T

R O

LS

3'

T O

R E

C E

P T

A C

LE

O

P E

N

IN

G

4'

M A

X

4'

M A

X

S P

O U

T

3'

M

IN

. T O

1 1/2" MIN.

1 1/2" O.D. MAX.

1 1/4" O.D. MIN.

MIN.

1' - 3"

S

IN

K S

U R

F A

C E

2'

0"

M A

X

3'

M A

X T

O

R E

F

LE

C T

IV

E

S U

R F

A C

E

6'

M

IN

1' - 6" MIN.

2'

M

IN

2'

0"

M A

X

1' - 3" 1' - 3"

1'

M A

X

4'

M

IN

MIN.

2' - 0"

MIN.

2' - 0"

3'

M

IN

1' - 3" MIN 1' - 3" MIN

5' - 0" MIN. CLEAR

3' - 6" MIN

1' - 8"

MAX

12"

1'

M

IN

2'

2' -9

T

O

" 4"

M

IN

1'

3'-3" TO 3' - 5"

3' -3

T

O

7" TO 9"

T O

'-7

1'

T O

'-7

1'

9" M

IN

C

LE

A

R

9" M

IN

C

LE

A

R

PARTITION SHALL NOT

EXTEND MORE THAN 20" IN

FRONT OF TELEPHONE FACE

FOR FRONT APPROACH & NOT

MORE THAN 10" FOR SIDE

APPROACH

3" MAX

NOTE: INSULATE ANY

EXPOSED PIPING

EXTENT OF UNOBSTRUCTED

FORWARD AND SIDE REACH

4'

M A

X M

IN

1'

MAX

10"

MAXIMUM

OBSTRUCTION

ALLOWED AT

SIDE REACH

ONLY

3'

0"

M A

X

HEIGHT OF

OBSTRUCTED

SIDE REACH

1' - 5"

MIN

12"

MIN

24"

MINIMUM CORRIDOR

WIDTH 44". SEE BUILDING

CODE FOR EXCEPTIONS

MAX

2' - 0"

(P E

R M

A N

U F

DIAPER CHANGING

STATION

R E

F

LE

C T

IV

E

S U

R F

A C

E

MAX.

6"

11" MIN.

T O

H

IG

H

F

S

IN

K

IM

C

O U

N T

E R

8" MIN.

USE:

STRAIGHT GRAB BAR 36" x 1 1/2" DIA (BACK WALL) STRAIGHT GRAB BAR 42" x 1 1/2" DIA (SIDE WALL) STRAIGHT GRAB BAR 18" x 1 1/2" DIA VERT. (SIDE

WALL)

MINIMUM STALL DEPTH IS 60"

CLEAR

PER IPC/MICHIGAN PLUMBING CODE

ANSI A117 REQUIREMENT IS 56"

MIN.

SANITARY

NAPKIN

DISPOSAL

TOILET

PAPER

DISPENSER

BACK-TO-BACK OUTLETS IN STUD WALLS

N E

A R

E S

T

M

O D

U

LE

S R

E Q

U

IR

E D

F

V

IC

E T

O C

LE

B

C K

S P

LA

S

H

6" 8"

ELECTRICAL DEVICES

OUTLET OR A/V

P/D/C DEVICES

1'

POWER / DATA /

COMMUNICATIO

N DEVICES

LOCATIONS ON

COLUMNS, BETWEEN

DOORS, ETC.

1'

EQ EQ

T H

IS

D

O C

U M

E N

T H

A S

B E

E N

P R

E P

A R

E D

B Y

A R

C H

IT

E

K T

U R

A P

LC

A

S A

N

IN

S T

R U

M E

N T

O F

S E

R V

IC

E

A

C H

IT

E

K T

U R

A P

L C

S H

A

LL

R E

T A

IN

A

L L

C O

M M

O N

L A

W , S

T A

T U

T O

R Y

A N

D O

T H

E R

R E

S E

R V

E D

R

IG

H T

S , I

N C

LU

D

IN

G

T

P Y

R

IG

H T

T H

E R

E T

O architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

-J un -2

1:

:1

P

M C

:\U se rs \k irs t\O ne D riv e\

D oc um en ts \a rc hi te kt ur a

P

LC

\P ro je ct s\

_G

R P

S U ni on

H ig h S ch oo l H ea lth C en te r\R ev it\ G

R P

S U ni on

H S

T re m on t B lv d C lin ic

_v 3.

rv t

As indicated

G-1

C O

D E

C O

M P

L

IA

N C

E P

L A

N S

G R

A N

D R

A P

ID

S

P U

B L

IC

S C

H O

O L

S

U N

IO

N

H S

H E

A L

T H

C E

N T

E R

R E

N O

V A

T

IO

N S

2 JUNE 2025

T

R E

M O

N T

B L V

D N

W

G R

A N

D R

A P

ID

S

M I

BIDS AND PERMITS

NO. DATE DESCRIPTION

1/4" = 1'-0"

CODE COMPLIANCE PLAN

AREA OF WORK

EXISTING WALL CONSTRUCTION

INTERIOR WALL GENERAL NOTES

NEW WALL CONSTRUCTION

1. CONSTRUCT ALL WALLS TIGHT TO DECK ABOVE AND EXTEND INTO DECK FLUTES AND

WEBS OF STEEL MEMBERS UNLESS OTHERWISE NOTED.

2. PROVIDE DEFLECTION TRACK AT THE TOP OF ALL INTERIOR NON-BEARING METAL

STUD WALLS CAPABLE OF ACCOMMODATING 3/4" ROOF/FLOOR DEFLECTION.

3. REFER TO CODE COMPLIANCE PLAN FOR RATED WALL LOCATIONS. FIRE RATED AND

SMOKE RESISTANT ASSEMBLIES SHALL BE CONTINUOUS, WITH OTHER PARTITIONS

ABUTTING THEM.

4. PROVIDE FIRESTOPPING/ SMOKE SEALANT AT ALL PENETRATIONS THROUGH FIRE

RATED AND SMOKE RESISTANT ASSEMBLIES, CORRIDORS, AND FLOORS WITH

OCCUPIABLE SPACES ABOVE AND BELOW.

5. PERMANENTLY IDENTIFY FIRE RATED AND SMOKE RESISTANT PARTITIONS ON WALL

ABOVE CEILINGS AT 30 FEET ON CENTER.

6. PROVIDE ACOUSTICAL SEALANT AT ALL WALLS WITH ACOUSTICAL INSULATION.

7. ALL WALLS ARE 3 5/8" METAL FRAMING 16" O/C WITH 5/8" GYPSUM WALLBOARD EA SIDE, EXTEND TO UNDERSIDE OF DECK UNLESS NOTED OTHERWISE.

GENERAL NOTES

1. DO NOT SCALE DRAWINGS.

2. EXISTING BUILDING CONDITIONS BASED ON OWNER PROVIDED DRAWINGS AND

LIMITED FIELD VERIFICATION. VERIFY EXACT CONDITIONS IN FIELD. SHOULD

DISCREPANCIES OCCUR, NOTIFY ARCHITECT FOR CLARIFICATIONS.

3. BEGINNING WORK INDICATES THAT THE CONTRACTOR HAS ACCEPTED AND

VERIFIED EXISTING CONDITIONS.

4. REFER TO CODE COMPLIANCE DRAWING(S) FOR LOCATIONS OF RATED

ASSEMBLIES AND CODE SUMMARY.

5. WALL DIMENSIONS ARE TO FACE OF MASONRY, FACE OF CONCRETE, FACE OF

STUDS, COLUMN CENTERLINE AS SHOWN OR EXISTING CONSTRUCTION UNLESS

OTHERWISE NOTED.

6. ALL DIMENSIONS ARE PERPENDICULAR AND PARALLEL, UNLESS NOTED

OTHERWISE.

7. REFER TO ALL DRAWINGS SHOWING NEW CONSTRUCTION AND COORDINATE

DEMOLITION REQUIRED TO COMPLETE NEW WORK SHOWN.

8. REFER TO DEMOLITION DRAWINGS AND OTHER DRAWINGS TO DETERMINE

LOCATIONS THAT REQUIRE PATCHING DUE TO REMOVAL OF EXISTING ITEMS,

INCLUDING MECHANICAL, PLUMBING AND ELECTRICAL ITEMS.

9. PATCH ALL DISTURBED EXISTING SURFACES WITH MATERIALS TO MATCH

EXISTING ADJACENT SURFACE CONSTRUCTION.

10. PROVIDE APPROVED SMOKE/FIRESTOPPING ASSEMBLIES AT ALL MECHANICAL

AND ELECTRICAL PENETRATIONS THROUGH FIRE RATED AND SMOKE RESISTANT

PARTITIONS IDENTIFIED ON CODE COMPLIANCE DRAWINGS.

1 1

2 2

5,7

5,7

5,7

5,7

5,7

5,7

5,7

5,7

5,7

5,7

NEW DOOR

IN EXISTING

OPENING

N E

W F

U

LL

L

IT

E D

O O

R

6' - 6"

WATER

DISP

3'

M

IN

2' - 4"

2'

5/

8" 2'

3'

2'

1' - 6"

3'

6'

3'

7' - 6"

3' - 6"

3' - 6" 3 5/8" 6' - 4" 3 5/8"

EXAM

EXAM

EXAM

BEHAVIORAL

108OFFICE | BREAK

DENTAL

MECH

GRPS OFFICE

RECEPTION

WAITING

TOILET

T-1

IT

14' - 4"

9'

/4

8'

10' - 2 3/16"8' - 6"

7'

3/ 4"

8'

/8

11' - 4 1/2"

8'

3/ 8"

A-3

A-3

A-3

A-3 A-35 6

REINSTALL

PASS

THROUGH

SYSTEM

HALLWAY

104 HALLWAY

HALLWAY

MED

0A

100B

T-1MIN 12"

4' - 6"

3'

/4

3'

3" 3'

3'

3"

3' - 7" 2' - 6"

8 1/4" 3' - 4"

REFMICRO

SCREEN WALL ON TOP

OF COUNTER

1/

4"

8' - 0"

4' - 10"

8'

2'

12' - 0"

2' - 2"

3'

1' - 6"

3'

1' - 6"

3' - 0

1' - 6"

NEW SOLID

SURFACE

COUNTERTOP WITH

SIDE PANELS, TYP

(3) WORKSTATIONS

NEW WALL INFILL TO

MATCH ADJACENT

CONSTRUCTION, THIS

CORNER.

WALL GUARDS

EVERY

EXPOSED

CORNER

HEAD TO MATCH DOOR

2'-0" X 4' - 0" 2' - 6"

COORDINATE

SIZE WITH

RACK SIZE

NEW OPENING IN

EXISTIGN WALL. PROVIDE

(2) AN

DEMOLITION NOTES

1. EXISTING BUILDING CONDITION BASED ON OWNER PROVIDED DRAWINGS AND

LIMITED FIELD VERIFICATION. VERIFY EXACT CONDITIONS IN FIELD. SHOULD

DISCREPANCIES OCCUR, NOTIFY ARCHITECT FOR CLARIFICATIONS.

2. BEGINNING WORK INDICATES THAT THE CONTRACTOR HAS ACCEPTED AND

VERIFIED EXISTING CONDITIONS.

3. COORDINATE DEMOLITION WITH ALL CONTRACTORS WORKING IN AREAS BEING

RENOVATED.

4. DURING DEMOLITION, PROTECT ALL ADJACENT CONSTRUCTION TO REMAIN.

5. ANY ASBESTOS CONTAINING MATERIALS THAT ARE ENCOUNTERED ARE TO BE

REMOVED BY THE OWNER.

6. REFER TO CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL AND COMMUNICATION

DRAWINGS FOR ITEMS TO BE REMOVED NOT SHOWN HERE.

7. COORDINATE THE RETURN AND STORAGE OF ALL ITEMS DESIGNATED AS

SALVAGE WITH OWNER.

8. PROVIDE TEMPORARY SHORING AND/OR STAGING OF THE DEMOLITION WORK.

9. MANY OF THE MASONRY WALLS OF THIS BUILDING ARE LOAD-BEARING.

COORDINATE DEMOLITION OF ALL WALLS OR PORTIONS OF WALLS FOR NEW

OPENINGS WITH STRUCTURAL DOCUMENTS AND EXISTING CONDITIONS.

CONTRACTOR IS RESPONSIBLE FOR SHORING ALL STRUCTURE SUPPORTED BY

BEARING WALLS PRIOR TO REMOVAL.

REMOVE EXISTING WALL OR PORTION OF EXISTING WALL AS SHOWN ON

FLOOR PLAN (MIN. 4" BELOW FLOOR SLAB) AND AS REQUIRED FOR NEW

CONSTRUCTION. FLOOR SURFACE TO BE PATCHED AS REQUIRED TO

RECEIVE NEW FLOOR MATERIAL. WALL SURFACE TO BE PATCHED AS

REQUIRED TO RECEIVE NEW WALL FINISH. SEE MECHANICAL & ELECTRICAL

DEMOLITION NOTES FOR RELATED ITEMS. SUPPORT UNBRACED SECTIONS

OF WALL OR ROOF AS REQUIRED.

REMOVE EXISTING DOOR & DOOR FRAME. (DOOR LINTEL TO REMAIN UNLESS

OTHERWISE NOTED ON PLAN -SEE S0.01 FOR ADDITIONAL INFORMATION).

WHERE DOOR FRAMES ARE TO REMAIN, PROTECT FRAMES FROM DAMAGE.

SAND AND PREP FOR NEW PAINT FINISH UNDER SECTION 09.900. SEE DOOR

SCHEDULE FOR REQUIRED NEW DOORS AND FRAMES OR ONLY NEW DOORS.

SAW CUT AND REMOVE FLOOR OR PORTION OF EXISTING FLOOR SLAB AS

SHOWN OR DIMENSIONED ON FLOOR PLAN. EXCAVATE, FILL & COMPACT SOIL

AS REQUIRED FOR NEW SLAB- COORDINATE WITH MECHANICAL/ ELECTRICAL

DEMOLITION NOTES FOR RELATED ITEMS & LOCATIONS. INSTALL NEW SLAB

TO MATCH EXIST. ELEVATION. SEE S0.01 & S2.1A FOR ADDITIONAL

INFORMATION REGARDING SLAB REMOVAL.

REMOVE EXISTING CASEWORK/MILLWORK, COUNTER TOPS & BACK SPLASH.

SAVE ITEMS AT OWNER'S REQUEST.

REMOVE EXISTING SUSPENDED/PLASTER CEILING-INCLUDING ALL FRAMING,

TILES, TEES, HANGERS & WIRES USED TO SUPPORT THAT CEILING. REPLACE

PER REFL. CEILING PLANS.

SEE MECHANICAL DEMOLITION NOTES FOR REMOVAL OF EXIST.

PLUMBING/MECHANICAL i.e. LAVATORIES, SINKS, WATER CLOSETS, URINALS, FIN TUBE, MECH. DUCTWORK, UNIT VENTS, ETC.

REMOVE EXISTING FLOOR COVERING AND BASE, INCLUDING ALL GLUE

RESIDUE, ETC. FROM FLOOR & WALLS AND PREPARE SURFACE FOR NEW

FINISH MATERIALS.

REMOVE AND SALVAGE PASS THROUGH SYSTEM

REMOVE ALL FIXTURES, TOILET ROOM ACCESSORIES, AND MIRRORS,

SALVAGE, REINSTALL AFTER NEW TILE AND FLOORING IS COMPLETED.

GENERAL FINISH PLAN NOTES

1. FLOORING:

A. ALL FLOORING MATERIALS SHALL BE INSTALLED IN DIRECTION INDICATED ON FINISH

PLAN(S), UNLESS OTHERWISE INDICATED.

B. PROVIDE A LEVELING COMPOUND BETWEEN FLOOR MATERIALS OF DIFFERENT

THICKNESS. FEATHER FLOOR FOR SMOOTH TRANSITION.

2. BASE:

A. TYPICAL BASE PROFILE AT CARPET SHALL BE STRAIGHT, UNLESS OTHERWISE

INDICATED ON PLAN.

B. TYPCIAL BASE PROFILE AT RESILENT FLOORING SHALL BE COVE, UNLESS

OTHERWISE INDICATED ON PLAN.

C. WHERE SHEET MATERIALS ARE USED, STANDARD BASE DETAIL SHALL BE FLASH

COVE, UNLESS OTHERWISE INDICATED. SEE SPECIFICATIONS MANUAL FOR MORE

INFORMATION.

3. WALLS:

A. ALL FIRE EXTINGUISHER CABINETS, IN FINISH OTHER THAN BRUSHED ALUMINUM,

SHALL BE PAINTED. COLOR TO MATCH ADJACENT WALL COLOR.

4. CEILINGS:

A. REFER TO INTERIOR FINISH LIST FOR CEILING TYPES. SEE REFLECTED CEILING

PLAN(S) FOR LOCATIONS AND HEIGHTS.

T H

IS

D

O C

U M

E N

T H

A S

B E

E N

P R

E P

A R

E D

B Y

A R

C H

IT

E

K T

U R

A P

LC

A

S A

N

IN

S T

R U

M E

N T

O F

S E

R V

IC

E

A

C H

IT

E

K T

U R

A P

L C

S H

A

LL

R E

T A

IN

A

L L

C O

M M

O N

L A

W , S

T A

T U

T O

R Y

A N

D O

T H

E R

R E

S E

R V

E D

R

IG

H T

S , I

N C

LU

D

IN

G

T

P Y

R

IG

H T

T H

E R

E T

O architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

-J un -2

1:

:1

P

M C

:\U se rs \k irs t\O ne D riv e\

D oc um en ts \a rc hi te kt ur a

P

LC

\P ro je ct s\

_G

R P

S U ni on

H ig h S ch oo l H ea lth C en te r\R ev it\ G

R P

S U ni on

H S

T re m on t B lv d C lin ic

_v 3.

rv t

As indicated

A-1

F

IR

S T

F L O

O R

A N

D D

E M

O L

IT

IO

N

P L

A N

S

R O

O M

F

IN

IS

H

E S

G R

A N

D R

A P

ID

S

P U

B L

IC

S C

H O

O L

S

U N

IO

N

H S

H E

A L

T H

C E

N T

E R

R E

N O

V A

T

IO

N S

2 JUNE 2025

T

R E

M O

N T

B L V

D N

W

G R

A N

D R

A P

ID

S

M I

BIDS AND PERMITS

1/4" = 1'-0"

FIRST FLOOR DEMOLITION PLAN

1/4" = 1'-0"

FIRST FLOOR PLAN

NO. DATE DESCRIPTION

ROOM FINISH SCHEDULE 1

ROOM FLOORS WALLS CEILING

REMARKSNO. NAME FINISH BASE NORTH EAST SOUTH WEST FINISH

FIRST FLOOR

100 WAITING CPT-1 RB-1 PT-1 ACP-1

101 RECEPTION CPT-1 RB-1 ACP-1

102 GRPS OFFICE CPT-1 RB-1 EX PATCH IN TO MATCH EXISTING

103 MECH EX RB-1 EX

104 HALLWAY LVT-1 RB-1 ACP-1

105 DENTAL LVT-1 RB-1 EX

106 MED LVT-1 RB-1 ACP-1

107 OFFICE | BREAK CPT-1 RB-1 EX PATCH IN TO MATCH EXISTING

108 BEHAVIORAL CPT-1 RB-1 ACP-1

109 EXAM LVT-1 RB-1 ACP-1

110 HALLWAY LVT-1 RB-1 ACP-1

111 EXAM LVT-1 RB-1 ACP-1

112 EXAM LVT-1 RB-1 EX PATCH IN TO MATCH EXISTING

113 HALLWAY LVT-1 RB-1 ACP-1

114 IT LVT-1 RB-1 ACP-1

T-1 TOILET LVT-1 PCT-1 ACP-1 Schluter Dilex-AHKA Aluminum Cove base Tile Edge Trim

REFLECTED CEILING PLAN GENERAL NOTES

1. ALL CEILING GRIDS ARE TO BE CENTERED IN ROOM / AREA OR ALIGNED WITH

ADJACENT ROOM / AREA AS INDICATED, UNLESS NOTED OTHERWISE.

2. CEILING HEIGHTS INDICATED ARE DIMENSIONED FROM THE FINISHED FLOOR

BELOW.

3. ALL LIGHT FIXTURES, SPRINKLER HEADS, RETURN AIR GRILLES AND SUPPLY AIR

GRILLES ARE TO BE LOCATED IN THE CENTER OF THE CEILING PAD, UNLESS

NOTED OTHERWISE.

4. FIRE PROTECTION CONTRACTOR TO COORDINATE LOCATIONS OF SPRINKLER

HEADS WITH MECHANCICAL AND ELECTRICAL CONTRACTOR. SEE NOTE ABOVE.

5. COORDINATE MECHANICAL, ELECTRICAL AND FIRE PROTECTION TO ASSURE

PROPER CLEARANCES AND LAYOUT.

6. MECHANICAL, ELECTRICAL AND FIRE PROTECTION CONTRACTORS TO PROVIDE

ACCESS PANELS IN CEILINGS AS REQUIRED FOR MAINTENANCE OF EQUIPMENT.

COORDINATE SIZE AND LOCATIONS OF ACCESS PANELS TO MINIMIZE

QUANTITIES. CONTRACTOR IS REQUIRED TO PROVIDE LAYOUT TO ARCHITECT

FOR REVIEW PRIOR TO INSTALLATION, UNLESS NOTED OTHERWISE.

REFLECTED CEILING PLAN LEGEND

EXISTING 2X4 ACOUSTIC CEILING PANEL

2X2 ACOUSTIC CEILING PANEL

EXISTING 2X2 ACOUSTIC CEILING PANEL

GYPSUM BOARD

EXISTING GYPSUM BOARD

RECESSED ROUND LIGHT FIXTURE

(EMERGENCY FIXTURES SHADED)

2X2 LIGHT FIXTURE

LINEAR LIGHT FIXTURE

HVAC SUPPLY GRILLE

HVAC RETURN GRILLE

S SPEAKER LOCATION

(SEE ELECTRICAL COMMUNICATIONS)

2X4 LIGHT FIXTURE

C

FIRE EXIT SIGN LOCATION

RADIANT PANEL

CAMERA LOCATION

(SEE ELECTRICAL COMMUNICATIONS)

8'-0" CEILING HEIGHT INDICATOR

CJ PLASTER OR GYPSUM WALL BOARD CONTROL JOINT

CEIILING ACCESS PANEL OR ROOF HATCH

CEILING MOUNTED PROJECTOR

EXAM

EXAM

EXAM

BEHAVIORAL

OFFICE | BREAK

DENTAL

MECH

GRPS OFFICE

102 RECEPTION

101 WAITING

TOILET

T-1

IT

PATCH IN CEILING

SYSTEM TO MATCH

EXISTING

PATCH IN CEILING

SYSTEM TO MATCH

EXISTING

ADJUST CEILING

SYSTEM AFTER

WALL IS INSTALLED

108' - 4"

108' - 4"

8' - 4" 8' - 4"

108' - 4"

108' - 4"

108' - 4"

108' - 4"

MED

HALLWAY

108' - 0"

T H

IS

D

O C

U M

E N

T H

A S

B E

E N

P R

E P

A R

E D

B Y

A R

C H

IT

E

K T

U R

A P

LC

A

S A

N

IN

S T

R U

M E

N T

O F

S E

R V

IC

E

A

C H

IT

E

K T

U R

A P

L C

S H

A

LL

R E

T A

IN

A

L L

C O

M M

O N

L A

W , S

T A

T U

T O

R Y

A N

D O

T H

E R

R E

S E

R V

E D

R

IG

H T

S , I

N C

LU

D

IN

G

T

P Y

R

IG

H T

T H

E R

E T

O architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

-J un -2

1:

:1

P

M C

:\U se rs \k irs t\O ne D riv e\

D oc um en ts \a rc hi te kt ur a

P

LC

\P ro je ct s\

_G

R P

S U ni on

H ig h S ch oo l H ea lth C en te r\R ev it\ G

R P

S U ni on

H S

T re m on t B lv d C lin ic

_v 3.

rv t

As indicated

A-2

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

G R

A N

D R

A P

ID

S

P U

B L

IC

S C

H O

O L

S

U N

IO

N

H S

H E

A L

T H

C E

N T

E R

R E

N O

V A

T

IO

N S

2 JUNE 2025

T

R E

M O

N T

B L V

D N

W

G R

A N

D R

A P

ID

S

M I

BIDS AND PERMITS

1/4" = 1'-0"

FIRST FLOOR REFLECTED CEILING PLAN

NO. DATE DESCRIPTION

24 84 25 30 25 30

25 33 25 33

2'

1'

2'

0"

24 30 24 30

24 33 24 33

2'

0"

1'

2'

36 24 36 30

36 3336 33

1'

2'

0"

2'

2'

0"

1'

2'

0"

PRIVACY

SCREEN

27 42 30 42 30 42 30 42 21 42

3'

TACKABLE PRIVACY PANEL

27 42 30 42 30 42 30 42 21 42

3'

TACKABLE PRIVACY PANEL

NOTE:

3/4" PARTICLE BOARD

BACKSPLASH AND TOP.

3/4" PARTICLE BOARD DOORS.

K&V STANDARDS AND SUPPORTS

SEE SPECIFICATIONS.

3/4" PARTICLE BOARD

ADJUSTABLE SHELF.

WALL BASE OVER 2x

WOOD FRAMING - SEE

ROOM FINISH SCHEDULE

3/4" PARTICLE BOARD DRAWER\

FRONTS W/ 1/2" SOLID WOOD

SIDES & BACK W/ 1/4" PARTICLE

BOARD BOTTOMS-DADO INTO

SIDES - SEE INT. ELEVATIONS

FOR COUNT. (TYPICAL)

ALL EXPOSED EXTERIOR

SURFACES AND TOP OF

INTERIOR SHELF SHALL BE

COVERED W/ PLASTIC LAM.

ALL INTERIOR SURFACES

INCLUDING THE UNDERSIDE

OF TOP SHALL BE COVERED

W/ BALANCE SHEET

1/2" PLYWOOD BACK WITH

DADO INTO SIDES OVER 3/4"

FURRING (SEE CUSTOM MILL-

WORK SPECS. FOR MOUNTING)

4"

3"

1/

2"1 1/2"

S E

E

IN

TE

R

IO

R

E

LE

V

4"

SEE INTERIOR ELEV.

3/4" PARTICLE BOARD

BACKSPLASH AND TOP.

ALL EXPOSED EXTERIOR

SURFACES SHALL BE

COVERED W/ PLASTIC

LAMINATE. ALL INTERIOR

SURFACES INCLUDING THE

UNDERSIDE OF TOP SHALL BE

COVERED W/ CABINET LINER.

WALL BASE OVER 2x

WOOD FRAMING - SEE

ROOM FINISH SCHEDULE

3/4" PARTICLE BOARD DRAWER

FRONTS W/ 1/2" SOLID WOOD

SIDES & BACK W/ 1/4" PARTICLE

BOARD BOTTOMS-DADO INTO

SIDES - SEE INT. ELEVATIONS

FOR COUNT. (TYPICAL)

NOTE:

4"

3"

SEE INTERIOR ELEVATIONS

T Y

P

1/ 4"

T Y

P

3/

4"

1/ 2"

1 1/2"

S E

E

IN

TE

R

IO

R

E

LE

V

4"

4" VINYL BASE

MET. SHELF

STANDARDS

& SUPPORTS

PLASTIC LAM. ON 3/4"

PLYWD. SHELVES W/

EDGE BAND (TYP.)

PLASTIC LAM. ON 3/4" PLYWD.

FASTEN TO 2x FRAMING

PLASTIC LAM. ON 3/4" PLYWD.

DOOR W/ EDGE BANDING

SHELF SUPPORT:

(2)-3/4"x3" GLUED & COUNTER-

SUNK SCREWED TOGETHER

W/ PLASTIC LAM. ON ALL EXPOSED

SURFACES,

SECURE TO SIDE PANELS

(TYP.)

2x2 CONT. WOOD NAILER

SECURED TO WALL

1' - 10"

7'

0"

1/

2" 3'

1/ 2"

3'

2"

2' - 0"

4"

3/4" PARTICLE BOARD

BACKSPLASH AND TOP.

3/4" PARTICLE BOARD DOORS.

WALL BASE OVER 2x

WOOD FRAMING - SEE

ROOM FINISH SCHEDULE

3/4" PARTICLE BOARD SINK FACE

ALL EXPOSED EXTERIOR

SURFACES AND TOP OF

INTERIOR SHELF SHALL

BE COVERED W/PLASTIC

LAMINATE. ALL INTERIOR\

SURFACES INCLUDING THE

UNDERSIDE OF TOP SHALL BE

COVERED W/BALANCE SHEET

1/2" PLYWOOD BACK WITH

DADO INTO SIDES OVER 3/4"

FURRING (SEE CUSTOM MILL-

WORK SPECS. FOR MOUNTING)

NOTE:

4"

E

LE

V A

TI

O

N S

S E

E

IN

TE

R

IO

R

ELEVATIONS

SEE INTERIOR

1 1/2"

1/

2"

4"

3"

3/4" PARTICLE BOARD DOORS.

K&V STANDARDS AND SUPPORTS

SEE SPECIFICATIONS.

3/4" PARTICLE BOARD TOP.

3/4" PARTICLE BOARD

ADJUSTABLE SHELVES.

3/4" PARTICLE

BOARD BOTTOM.

ALL EXPOSED EXTERIOR

SURFACES AND TOP OF INTERIOR

SHELFS SHALL BE COVERED W/

PLASTIC LAMINATE. ALL INTERIOR

SURFACES INCLUDING THE

UNDERSIDE OF TOP SHALL BE

COVERED W/ BALANCE SHEET

1/2" PLYWOOD BACK WITH

DADO INTO SIDES OVER 3/4"

FURRING (SEE CUSTOM MILL-

WORK SPECS. FOR MOUNTING)

NOTE:

1' - 3"

DOORS TO BE PLASTIC

LAMINATE OVER 3/4"

PLYWOOD

K&V STANDARDS &

SUPPORTS - SEE

SPECS.

3/4" PLYWOOD SHELF

(ADJUSTABLE)

WALL BASE OVER 2x

WOOD FRAMING - SEE

ROOM FINISH SCHEDULE

CENTER SUPPORT TO BE

2x4 FRAME WITH (1) LAYER

OF 1/2" PLYWOOD ON

EACH SIDE

PLASTIC LAMINATE OVER

(2) LAYERS OF 3/4" PLYWOOD

W/ CORIAN EDGE- 2" BULLNOSE

3" 3"

1' - 8 3/4" 2 1/2" 1' - 8 3/4"

8"

(3 4"

B F/

A D

A

3'

0"

DOOR TYPES

F FG

S E

E S

C H

E D

U

LE

S E

E S

C H

E D

U

LE

SEE SCHEDULE

SEE SCHEDULE

SEE SCHEDULE

2" 2"

2" S

E E

S C

H E

D U

LE

XX 2"

SCHEDULE

SEE XX2"

2" S

E E

S C

H E

D U

LE

X X

2"

FRAME TYPES

ALL EXPOSED COUNTER

SURFACES BE COVERED W/

PLASTIC LAMINATE.

PROVIDE GROMMETS

2' - 0"

2'

CONCEALED BRACKETS

3' - 0"

SOLID SURFACE OVER

SUBSTRATE

NOTE:

2x6 CONT.

2x4 CONT.

TAPERED 2x6

WOOD FRAMING.

3/4" PARTICLE BOARD

BACKSPLASH AND TOP.

3/4" PARTICLE BOARD FRONT.

DASHED LINE INDICATES

3/4" PARTICLE BOARD END

PANEL TO BE INSTALLED AT

CONDITION WHERE COUNTER

IS NOT BETWEEN WALLS -

PROVIDE MOUNTING AS

REQUIRED.

ALL EXPOSED COUNTER

SURFACES BE COVERED W/

PLASTIC LAMINATE.

4"

2' - 1"

5"

3"

4"

JAMB 3/

8"

BULLNOSE BLOCK.

DOOR FRAME W/ GROUT

FILL - SEE DOOR & FRAME

SCHEDULE FOR TYPE.

SEE DOOR SCHEDULE

FOR DOOR TYPE.

PROVIDE (3) ANCHORS

PER JAMB MINIMUM

W/ GROUT INFILL.

HEAD

EXISTING BLOCK WALL

TO REMAIN.

"TOOTH - IN" NEW MASONRY

AS REQUIRED FOR NEW DOOR

OPENING IN EXISTING WALL.

(2) STEEL ANGLE LINTEL

W/ 8" MIN. BEARING EACH

SIDE

3/8"

EXISTING MASONRY WALL

TO REMAIN (REPAINT)

CONT. BACKER ROD & SEALANT

AROUND FRAME PERIMETER

BOTH SIDES.

NEW MASONRY AT EACH SIDE

OF LINTEL (PAINTED). MATCH

EXISTING

NOTE:

SEE PLANS FOR

EXACT WALL

CONFIGURATION.

JAMB

NOTE:

(2) 3.5/8"x 20 GA. METAL

STUDS AT JAMB - CONTINUE

TO STRUCTURE ABOVE AT

BOTH SIDES OF OPENING (TYP.)

SEE DOOR HEAD FOR TYP.

NOTES AT JAMB CONDITION

HEAD

(2) 3.5/8"x 20 GA. METAL

CHANNEL HEADER.

SEALANT AROUND PERIMETER

BOTH SIDES.

HOLLOW METAL DRYWALL

FRAME - SEE DOOR AND

FRAME SCHEDULE.

SEE DOOR SCHEDULE

FOR DOOR TYPE.

SOUND BATT INSULATION.

5/8" FIRE CODE GYP.BD.

OVER BOTH SIDES OF 3.5/8"x 20 GA. METAL STUDS AT 16"o/c.

(EXTEND TO DECK ABOVE)

T H

IS

D

O C

U M

E N

T H

A S

B E

E N

P R

E P

A R

E D

B Y

A R

C H

IT

E

K T

U R

A P

LC

A

S A

N

IN

S T

R U

M E

N T

O F

S E

R V

IC

E

A

C H

IT

E

K T

U R

A P

L C

S H

A

LL

R E

T A

IN

A

L L

C O

M M

O N

L A

W , S

T A

T U

T O

R Y

A N

D O

T H

E R

R E

S E

R V

E D

R

IG

H T

S , I

N C

LU

D

IN

G

T

P Y

R

IG

H T

T H

E R

E T

O architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

-J un -2

1:

:1

P

M C

:\U se rs \k irs t\O ne D riv e\

D oc um en ts \a rc hi te kt ur a

P

LC

\P ro je ct s\

_G

R P

S U ni on

H ig h S ch oo l H ea lth C en te r\R ev it\ G

R P

S U ni on

H S

T re m on t B lv d C lin ic

_v 3.

rv t

As indicated

A-3

D O

O R

S C

H E

D U

L E

D

E T

A

IL

S

A N

D E

L E

V A

T

IO

N S

G R

A N

D R

A P

ID

S

P U

B L

IC

S C

H O

O L

S

U N

IO

N

H S

H E

A L

T H

C E

N T

E R

R E

N O

V A

T

IO

N S

2 JUNE 2025

T

R E

M O

N T

B L V

D N

W

G R

A N

D R

A P

ID

S

M I

BIDS AND PERMITS

DOOR SCHEDULE

Mark

DOOR FRAME

RATING HDW NOTESWIDTH HEIGHT TYPE MATERIAL TYPE MATERIAL

FIRST FLOOR

100A 3' - 0" 7' - 0" F WD S HM 06

100B 3' - 0" 7' - 0" FG WD S HM 05

101 3' - 0" 7' - 0" FG WD S HM 02

102 3' - 0" 7' - 0" FG HM S HM 09

107 3' - 0" 7' - 0" FG WD S HM 02

108 3' - 0" 7' - 0" F WD S HM 03

109 3' - 0" 7' - 0" F WD S HM 01

110 3' - 0" 7' - 0" FG WD S HM 07

111 3' - 0" 7' - 0" F WD S HM 01

114 2' - 0" 7' - 0" F HM S HM 08

T-1 3' - 0" 7' - 0" F WD S HM 04

NO. DATE DESCRIPTION

1/2" = 1'-0"

ELEVATION

1/2" = 1'-0"

ELEVATION

1/2" = 1'-0"

ELEVATION

1/2" = 1'-0"

ELEVATION

1/2" = 1'-0"

ELEVATION

1/2" = 1'-0"

ELEVATION

1" = 1'-0"

BASE CABINET DETAIL

1" = 1'-0"

DRAWER BASE CABINET DETAIL

1" = 1'-0"

TALL CABINET DETAIL

1" = 1'-0"

SINK BASE CABINET DETAIL

1" = 1'-0"

UPPER WALL CABINET DETAIL

1" = 1'-0"

WORK AREA TABLE DETAIL

1" = 1'-0"

VV

COUNTER

1" = 1'-0"

COUNTER DETAIL

1 1/2" = 1'-0"

DOOR DETAILS

WH WH

TH

IS

D

OC

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D

BY

A

RC

HI

TE

KT

UR

A

PL

C

AS

A

N

IN

ST

RU

ME

NT

O F

SE

RV

IC

E, A

ND

AR

CH

IT

EK

TU

RA

P

LC

S

HA

LL

R

ET

AI

N

AL

L C

OM

MO

N

LA

W

, S

TA

TU

TO

RY

A

ND

O

TH

ER

R

ES

ER

VE

D

RI

GH

TS

, IN

CL

UD

IN

G

TH

E

CO

PY

RI

GH

T

TH

ER

ET

O.

architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

4/1 0/2

5 1

0:4 2:3

2 A M

C:

\U se rs\ kir st\

On eD riv e\D oc um en ts\ ar ch ite ktu ra P

LC

\P ro jec ts\

_G

RP

S

Un ion

H igh

S ch oo l H ea lth

C en ter \R ev it\G

RP

S

Un ion

H S

Tr em on t B lvd C lin ic_ v3 .rv t

As indicated

G R

AN

D

R

AP

ID

S

PU

BL

IC

SC

H O

O

LS

U N

IO

N

H S

H

EA

LT

H

C

EN

TE

R

R

EN

O

VA

TI

O

N S

2 JUNE 2025

T R

EM

O

N T

BL

VD

N W

, G R

AN

D

R

AP

ID

S

M I 4

BIDS AND PERMITS

NO. DATE DESCRIPTION

P-1

FI

R

ST

F

LO

O

R A

N D

D

EM

O

LI

TI

O

N P

LA

N

06.02.25

EXAM

EXAM

EXAM

BEHAVIORAL

OFFICE | BREAK

DENTAL

MECH

GRPS OFFICE

RECEPTION

101 WAITING

TOILET

T-1

IT

MED

HALLWAY

TH

IS

D

OC

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D

BY

A

RC

HI

TE

KT

UR

A

PL

C

AS

A

N

IN

ST

RU

ME

NT

O F

SE

RV

IC

E, A

ND

AR

CH

IT

EK

TU

RA

P

LC

S

HA

LL

R

ET

AI

N

AL

L C

OM

MO

N

LA

W

, S

TA

TU

TO

RY

A

ND

O

TH

ER

R

ES

ER

VE

D

RI

GH

TS

, IN

CL

UD

IN

G

TH

E

CO

PY

RI

GH

T

TH

ER

ET

O.

architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

4/1 0/2

5 1

0:4 2:3

2 A M

C:

\U se rs\ kir st\

On eD riv e\D oc um en ts\ ar ch ite ktu ra P

LC

\P ro jec ts\

_G

RP

S

Un ion

H igh

S ch oo l H ea lth

C en ter \R ev it\G

RP

S

Un ion

H S

Tr em on t B lvd C lin ic_ v3 .rv t

As indicated

G R

AN

D

R

AP

ID

S

PU

BL

IC

SC

H O

O

LS

U N

IO

N

H S

H

EA

LT

H

C

EN

TE

R

R

EN

O

VA

TI

O

N S

2 JUNE 2025

T R

EM

O

N T

BL

VD

N W

, G R

AN

D

R

AP

ID

S

M I 4

BIDS AND PERMITS

NO. DATE DESCRIPTION

M-1

FI

R

ST

F

LO

O

R A

N D

D

EM

O

LI

TI

O

N P

LA

N

SYMBOL NOTES:

1. "AC" DENOTES ABOVE COUNTER. COORDINATE HEIGHT WITH ARCHITECT.

2. "H" DENOTES HORIZONTAL MOUNTING OF DEVICE.

3. "B" DENOTES MOUNTED IN BASE.

4. "F" DENOTES MOUNTED IN FACE OF CABINETS.

D

S

SECURITY INTERCOM

SECURITY DOOR CONTACT

CEILING SPEAKER

AUDIO ONLY ALARM

VISUAL ONLY ALARM

FIRE ALARM CONTROL RELAY

REMOTE ALARM KEY TEST SWITCH

WATER FLOW SWITCH

O,S,&Y TAMPER SWITCH

HEAT DETECTOR

DUCT SMOKE DETECTOR

AREA SMOKE DETECTOR-PHOTOELECTRIC

FIRE ALARM PULL STATION

CEILING SPEAKER

SPEAKER/STROBE LIGHT

LMTG. HT. TO CDESCRIPTIONSYMBOL

SYSTEMS SYMBOL LEGEND

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

F

CO

CR

FS

D

TS

RT

F.A.A.

F.A.C.P.

F.A. NOTES:

1. E.C. TO PROVIDE CONNECTION TO ALL DUCT DETECTORS WHETHER SHOWN ON ELECTRICAL

DRAWINGS OR NOT. COORDINATE QUANTITY AND LOCATIONS WITH MECHANICAL

CONTRACTOR SCHEDULES, REVIEWING ALL CFM REQUIREMENTS. PROVIDE DUCT

DETECTORS IF NOT NOTED TO BE PROVIDE BY M.C.

2. E.C. TO PROVIDE CONNECTIONS TO ALL FLOW AND TAMPER SWITCHES WHETHER SHOWN ON

ELECTRICAL DRAWINGS OR NOT. COORDINATE QUANTITY AND LOCATIONS WITH FIRE

PROTECTION DRAWINGS AND/OR DESIGN BUILD CONTRACTOR.

3. E.C. TO PROVIDE EMERGENCY POWER TO FIRE ALARM BOOSTER POWER SUPPLIES WHEN

EMERGENCY POWER SYSTEM IS AVAILABLE.

SECURITY DOOR REQUEST TO EXIT

CO

R CARD READER

MAGNETIC DOOR HOLD OPENDH

CARBON MONOXIDE SENSOR. E.C TO ROUGH-IN SINGLE

GANG BOX AND 1/2"C. TO ACCESSIBLE CEILING SPACE.

46"

80"

80"

46"

46"

AT DOOR HEAD

46"

AT DOOR HEAD

TYPICALLY CLG

MOUNTED

SMOKE/HORN BASE

CO-DENOTES COMBO CARBON MONOXIDE/SMOKE

I

C

X

H

FIRE/SMOKE DAMPER

BEAM DETECTOR

F/SD

BD ---

SECURITY CAMERA - "W" DENOTES WALL MOUNTED

CHEVRON INDICATES AIM LINE

WP FIRE ALARM HORN/STROBE LIGHT

(WP-DENOTES WEATHER PROOF)

T THERMOSTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND

1/2"C. TO ACCESSIBLE CEILING SPACE.

TRANSFORMER

SURFACE OR FLUSH MTD. BRANCH CIRCUIT PANELBOARD

THREE PHASE ELECTRIC MOTOR

SINGLE PHASE ELECTRIC MOTOR

MAGNETIC MOTOR STARTER-MS

DIMMER SWITCH

46"

KEY OPERATED SWITCH-SPEC. GRADE

FOUR WAY SWITCH-SPEC. GRADE

T

F

P

F

J

ELECTRICAL SYMBOL LEGEND

S

S

S

WR

D

K

S

SYMBOL DESCRIPTION

MTG. HT. TO CL

SPECIAL OUTLET-CHARACTERISTICS AS NOTED ON PLANS

FLOOR BOX 1 RECEPT, 1 DATA - THOMAS & BETTS-# 664-SC

1-1/4"C TO FLOORBOX FOR DATA

FLOOR BOX 2 RECEPT, 2 DATA THOMAS & BETTS-# 665-SC

1-1/4"C TO FLOORBOX FOR DATA

OS

IRDS IR SWITCH DIMMABLE

OCCUPANCY SENSOR

PUSH BUTTONPB

TV

IRS IR SWITCH

CS CONTROL STATION

C

SPECIAL SINGLE RECEPTACLE

VARIABLE FREQUENCY DRIVEVFD

PC PHOTO CELL

46"

46"

46"

46"

46"

46"

18"

18"

18"

18"

18"

AS NOTED

18"

46"

46"

46"

AT EQUIP.

AS NOTED

AS NOTED

46"

46"

46"

46"

72" TO TOP

18"

SINGLE POLE OR 3-WAY SWITCH-

SPECIFICATION GRADE

SPLIT WIRED RECEPTACLE

C - DENOTES CONTROLLED VIA RELAY OR OCC SENSOR

WATER RESISTANT GROUND FAULT CIRCUIT INTERRUPTER

WITH WEATHERPROOF WHILE IN USE COVER

DUPLEX OUTLET-SPEC. GRADE

CIRCLE AROUND SYMBOL= CEILING MOUNTED

DATA OUTLET-4" SQ. BOX W/ 1 GANG RAISED COVER.

1-1/4"C. UP WALL TO CLG. SPACE

CIRCLE AROUND SYMBOL= CEILING MOUNTED

TV OUTLET-4" SQ. BOX W/ 1 GANG RAISED COVER.

1-1/4"C. UP WALL TO CLG. SPACE

CIRCLE AROUND SYMBOL= CEILING MOUNTED

JUNCTION BOX - HUBBELL NSAV62M WITH RECEPTACLE KIT

HUBBELL NSOKP. PROVIDE CONNECTOR PLATE FOR A/V

JUNCTION BOX -4" SQ. BOX W/ 2 GANG RAISED COVER.

1"C. UP WALL TO CLG. SPACE UNLESS OTHERWISE NOTED

FUSED DISCONNECT SWITCH-

FDS-HEAVY DUTY

NON-FUSED DISCONNECT SWITCH-

NFDS-HEAVY DUTY

SW. AND PLUGFUSE HOLDER- BUSSMANN

"SSU" & FUSESTAT FUSE

COMBINATION MAG. STARTER/ FUSED DISC. SWITCH - CS/FDS

COMBINATION MAG. STARTER/NON-FUSED DISC.

SWITCH - CS/NFDS

(2) DUPLEX OUTLET-SPEC. GRADE

CIRCLE AROUND SYMBOL= CEILING MOUNTED

S

PARTIALLY SHADED LUMINAIRE OR WITH "E" SUFFIX ARE

EMERGENCY

BATTERY EMERGENCY LUMINAIRE

REMOTE EMERGENCY HEAD

RECESSED LUMINAIRE 2'x4' OR 2'x2'

RECESSED WALLWASH LUMINAIRE

RECESSED DOWNLIGHT LUMINAIRE

LED ACCENT/UNDER CABINET LUMINAIRE

TRACK LIGHTING LUMINAIRE

SURFACE LUMINAIRE

WALL MOUNTED LUMINAIRE

PENDANT LUMINAIRE

SITE LIGHTING LUMINAIRE

NIGHT LIGHT

STRIP LUMINAIRE

SURFACE LUMINAIRE 2'x4' OR 2'x2'

EXIT SIGN - WALL MOUNTED OR CEILING MOUNTED

ARROWS INDICATE PATH OF EGRESS

NL

EE

H HUMIDISTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND

1/2"C. TO ACCESSIBLE CEILING SPACE. 46"

WN ---

PS SWITCH WITH PILOT LIGHT 46"

18"TELEPHONE OUTLET-4" SQ. BOX W/ 1 GANG RAISED

COVER. 1-1/4"C. UP WALL TO CLG. SPACE

18"TELEPHONE/DATA OUTLET-4" SQ. BOX W/ 1 GANG

RAISED COVER. 1-1/4"C. UP WALL TO CLG. SPACE

M ---ELECTRIC UTILITY METER

P ---POWER POLE - SEE DRAWING FOR POWER -

POWER/DATA SPECIFICATIONS

DS DAYLIGHT SENSOR ---

MS MANUAL MOTOR STARTER SWITCH 46"

ELECTRICAL IDENTIFICATION

N.T.S.

FRONT

REAR SIDE

OF PLATE

FRONT

REAR SIDE OF

PLATE

BPA-15LP2-5

LABEL CKT. NO. OF EACH DEVICE ON REAR

SIDE OF COVER PLATE. USE PERMANENT

MARKER PEN, BRADY MARKING SYSTEM OR

OTHER METHOD APPROVED BY THE ENGINEER

JUNCTION BOXES (EXPOSED

OR CONCEALED ABOVE

ACCESSIBLE CEILING)

LABEL COVERS WITH CKT.'S CONTAINED

WITHIN. USE PERMANENT MARKER PEN

OR OTHER APPROVED METHOD.

FOR J.B.'S CONTAINING OTHER

THAN POWER OR LIGHTING CKT.'S

LABEL COVERS INDICATING

SYSTEM TYPE AND ZONES.

CKT.S

LP4-13,15,17

DUPLEX RECEPTACLE

PLATE

STANDARD TOGGLE

SWITCH PLATE

LABEL EXAMPLES:

"FIRE ALARM-ZONES 2&3"

"P.A. ZONES 4,5,&6" "DATA

CIRCUITS A&B" "EXIT

SIGNS-EMI&2" "EMERG.

CKTS. BPEM-3,4"

E1.00 A-1

As indicated

E1.00

D E

TA

IL

S , S

Y M

B O

L

LE

G E

N D

S A

N D

S P

E C

IF

IC

A

TI

O N

S

TH

IS

D

OC

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D

BY

A

RC

HI

TE

KT

UR

A

PL

C

AS

A

N

IN

ST

RU

ME

NT

O F

SE

RV

IC

E, A

ND

AR

CH

IT

EK

TU

RA

P

LC

S

HA

LL

R

ET

AI

N

AL

L C

OM

MO

N

LA

W

, S

TA

TU

TO

RY

A

ND

O

TH

ER

R

ES

ER

VE

D

RI

GH

TS

, IN

CL

UD

IN

G

TH

E

CO

PY

RI

GH

T

TH

ER

ET

O.

architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

4/1 0/2

5 1

0:4 2:3

2 A M

C:

\U se rs\ kir st\

On eD riv e\D oc um en ts\ ar ch ite ktu ra P

LC

\P ro jec ts\

_G

RP

S

Un ion

H igh

S ch oo l H ea lth

C en ter \R ev it\G

RP

S

Un ion

H S

Tr em on t B lvd C lin ic_ v3 .rv t

As indicated

G R

A N

D R

A P

ID

S

P U

B

LI

C S

C H

O O

LS

U N

IO

N

H S

H E

A

LT

H C

E N

TE

R

R E

N O

V A

TI

O

N S

2 JUNE 2025

T R

E M

O N

T B

LV

D

N W

, G R

A N

D R

A P

ID

S

M I 4

BIDS AND PERMITS

NO. DATE DESCRIPTION

P :\2

5\

G R

P S

U ni on H

S C lin ic

\W or ki ng

D ra w in gs \2

E

2.

dw g, /2 /2

3:

:4

P M

, m de lo ra

ONE-LINE DIAGRAM GENERAL NOTES

1. REFER TO WIRE SIZING CHART. COPPER OR ALUMINUM MAY BE UTILIZED AT

CONTRACTORS DISCRETION UNLESS OTHERWISE NOTED. COORDINATE ROUTING

WITH TRADES ON SITE.

2. PROVIDE HAZARD LABELS PER CODE MEETING ANSI Z535.4.

3. VERIFY HVAC MOTOR CIRCUIT PROTECTION AND TEST THERMAL OVERLOAD

PROTECTION ON HVAC MOTORS.

BRANCH FEEDERS - 3 WIRE (COPPER)

30A 3-#10+#10G,3/4"C 40A 3-#8+#10G,3/4"C 60A 3-#6+#10G,3/4"C 80A 3-#4+#8G,3/4"C 100A 3-#3+#8G,1"C 125A 3-#1+#6G,1-1/2"C 200A 3-#4/0+#4G,2"C 225A 3-#4/0+#4G,2"C

TYPICAL AMPERAGE/CONDUCTOR

SIZES FOR ONE-LINE

BRANCH FEEDERS - 4 WIRE (COPPER)

60A 4-#6+#10G,1"C 100A 4-#3+#8G,1-1/4"C 125A 4-#1+#6G,1-1/2"C 150A 4-#1/0+#6G,1-1/2"C 175A 4-#2/0+#6G,2"C 200A 4-#4/0+#4G,2-1/2"C 250A 4-#250kcmil+#4G,2-1/2"C 400A 4-#600kcmil+#3G,3-1/2"C 600A (2)4-#350kcmil+#1G,3"C 800A (2)4-#600kcmil+1/0G,4"C 1200A (4)4-#350kcmil+3/0G-3"C

29 120/208V- 3Ø-4W ONE LINE

NOT TO SCALE

SERVICE FEEDERS (COPPER)

60A 4-#4+#10G, 1-1/4"C 100A 4-#1+#8G,1-1/2"C 125A 4-#2/0+#6G, 2"C 150A 4-#3/0+#6G, 2"C 200A 4-#250kcmil, 2-1/2"C 225A 4-#300kcmil, 3"C 400A (2)4-#250kcmil, 2-1/2"C 600A (2)4-#500kcmil, 3"C 800A (3)4-#400kcmil, 3-1/2"C 1200A (4)4-#500kcmil, 3-1/2"C 1400A (5)4-#500kcmil, 3-1/2"C 1600A (6)4-#400kcmil, 3"C 2000A (7)4-#500kcmil, 3-1/2"C 2500A (9)4-#500kcmil, 3-1/2"C D7

EX. PANEL

As indicated

E2.00

O N

E -L

IN

E

D

IA

G R

A M

TH

IS

D

OC

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D

BY

A

RC

HI

TE

KT

UR

A

PL

C

AS

A

N

IN

ST

RU

ME

NT

O F

SE

RV

IC

E, A

ND

AR

CH

IT

EK

TU

RA

P

LC

S

HA

LL

R

ET

AI

N

AL

L C

OM

MO

N

LA

W

, S

TA

TU

TO

RY

A

ND

O

TH

ER

R

ES

ER

VE

D

RI

GH

TS

, IN

CL

UD

IN

G

TH

E

CO

PY

RI

GH

T

TH

ER

ET

O.

architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

4/1 0/2

5 1

0:4 2:3

2 A M

C:

\U se rs\ kir st\

On eD riv e\D oc um en ts\ ar ch ite ktu ra P

LC

\P ro jec ts\

_G

RP

S

Un ion

H igh

S ch oo l H ea lth

C en ter \R ev it\G

RP

S

Un ion

H S

Tr em on t B lvd C lin ic_ v3 .rv t

As indicated

G R

A N

D R

A P

ID

S

P U

B

LI

C S

C H

O O

LS

U N

IO

N

H S

H E

A

LT

H C

E N

TE

R

R E

N O

V A

TI

O

N S

2 JUNE 2025

T R

E M

O N

T B

LV

D

N W

, G R

A N

D R

A P

ID

S

M I 4

BIDS AND PERMITS

NO. DATE DESCRIPTION

P :\2

5\

G R

P S

U ni on H

S C lin ic

\W or ki ng

D ra w in gs \2

E

2.

dw g, /2 /2

3:

:5

P M

, m de lo

EXAM

EXAM

109BEHAVIORAL

108OFFICE | BREAK

DENTAL

MECH

GRPS OFFICE

RECEPTION

101 WAITING

TOILET

T-1

IT

HALLWAY

HALLWAY

HALLWAY

MED

EX. EX. EX. EX.

EX.EX.EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX. EX.

EX.EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX. EX.

IR

EX.

EX.

EX.

EX.

E

EX.

E

EX.

E

1 2

EX.

EX.

E

EX.

EX

EX

R5

R

R E

EX.

E

D D

DD

C C

C

C

C

IRD

IR

EM

A

IRD

EX. E

EX.

E

R

EX. EX.

B

EX

IRIRD

R

R E

EX. EX.

EX. R

UC2

UC3

UC3

UC3

OS

UC2 3

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

R

As indicated

EL-1

FI

R

S T

FL

O

O R

A N

D D

E M

O

LI

TI

O

N P

LA

N

S

- L

IG

H

TI

N

G

TH

IS

D

OC

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D

BY

A

RC

HI

TE

KT

UR

A

PL

C

AS

A

N

IN

ST

RU

ME

NT

O F

SE

RV

IC

E, A

ND

AR

CH

IT

EK

TU

RA

P

LC

S

HA

LL

R

ET

AI

N

AL

L C

OM

MO

N

LA

W

, S

TA

TU

TO

RY

A

ND

O

TH

ER

R

ES

ER

VE

D

RI

GH

TS

, IN

CL

UD

IN

G

TH

E

CO

PY

RI

GH

T

TH

ER

ET

O.

architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

4/1 0/2

5 1

0:4 2:3

2 A M

C:

\U se rs\ kir st\

On eD riv e\D oc um en ts\ ar ch ite ktu ra P

LC

\P ro jec ts\

_G

RP

S

Un ion

H igh

S ch oo l H ea lth

C en ter \R ev it\G

RP

S

Un ion

H S

Tr em on t B lvd C lin ic_ v3 .rv t

As indicated

G R

A N

D R

A P

ID

S

P U

B

LI

C S

C H

O O

LS

U N

IO

N

H S

H E

A

LT

H C

E N

TE

R

R E

N O

V A

TI

O

N S

2 JUNE 2025

T R

E M

O N

T B

LV

D

N W

, G R

A N

D R

A P

ID

S

M I 4

BIDS AND PERMITS

NO. DATE DESCRIPTION

SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"

GENERAL LIGHTING NOTES:

1. CONNECT EMERGENCY LIGHTING TO CIRCUIT FEEDING GENERAL LIGHTING IN THAT AREA.

2. EXIT SIGNS TO BE CONNECTED TO UNSWITCHED LIGHTING CIRCUIT OR EMERGENCY LIGHTING

CIRCUIT FEEDING THAT AREA. RECONNECT IF RELOCATED TO SAME CIRCUIT.

3. LIGHTING CONTROL SHALL COMPLY WITH 2021 MICHIGAN ENERGY CODE WHERE APPLICABLE.

4. ALL EXISTING LIGHTS TO REMAIN ARE LED.

5. REUSE EXISTING LIGHTING CIRCUITS FED FROM PANEL D7 LOCATED IN MECHANICAL ROOM #10.

LIGHTING KEY NOTES:

PROVIDE NEW BATTERY EMERGENCY LIGHT FIXTURE TO ILLUMINATE EXISTING ELECTRICAL PANEL.

REUSE EXISTING LIGHTS. RELOCATE AS SHOWN.

NEW LIGHTS WILL BE TAGGED AND CALLED OUT ON FIXTURE SCHEDULE.

EXISTING LIGHTS IN CORRIDORS UNLESS NOTED ARE TO REMAIN.

RELOCATE EXISTING LIGHT CONTROL SWITCH. EXTEND EXISTING CIRCUIT.

LIGHTS DESIGNATED AS R, RECONNECT TO EXISTING CIRCUIT IN AREA.

RECONNECT EXISTING LIGHTS CONNECTED TO EMERGENCY GENERATOR.

EXISTING LIGHTS TO REMAIN.

EXISTING LIGHTS TO BE TAKEN DOWN, CLEANED AND REINSTALLED.

EXISTING RECESSED LIGHTS TO BE REMOVED.

EXISTING EXIT LIGHTS TO REMAIN.

EXISTING LIGHTS TO BE REMOVED. TURN OVER TO OWNER.

DEMOLITION LIGHTING KEYNOTES:

P :\2

5\

G R

P S

U ni on H

S C lin ic

\W or ki ng

D ra w in gs \2

E

1.

dw g, /2 /2

3:

:3

P M

, m de lo

EXAM

EXAM

109BEHAVIORAL

108OFFICE | BREAK

DENTAL

MECH

GRPS OFFICE

RECEPTION

101 WAITING

TOILET

T-1

IT

HALLWAY

HALLWAY

HALLWAY

MED

1 1

JJ

EX.

EX.

AC

AC AC

AC

AC

AC

AC 2

AC

AC

EX.

EX.

EX.

EX.

EX. PANEL

D7

EX. PANEL

D7

EX.

EX.

EX.

EX.

EX. AC

AC

EX.

AC

AC

AC

AC AC

AC

AC

AC

AC

EX. EX. EX.

EX.

EX.

EX.

D7-28

5 5

D7-17

D7-32

AC

D7-30

EX. EX.

EX.

EX.

EX.

As indicated

EP-1TH

IS

D

OC

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D

BY

A

RC

HI

TE

KT

UR

A

PL

C

AS

A

N

IN

ST

RU

ME

NT

O F

SE

RV

IC

E, A

ND

AR

CH

IT

EK

TU

RA

P

LC

S

HA

LL

R

ET

AI

N

AL

L C

OM

MO

N

LA

W

, S

TA

TU

TO

RY

A

ND

O

TH

ER

R

ES

ER

VE

D

RI

GH

TS

, IN

CL

UD

IN

G

TH

E

CO

PY

RI

GH

T

TH

ER

ET

O.

architektura PO Box 971 Grand Haven, MI 49417 p: 616.843.1002 www.architekturaplc.com

ISSUANCES

SCALE :

REVISIONS

PROJECT NO.

PLC

4/1 0/2

5 1

0:4 2:3

2 A M

C:

\U se rs\ kir st\

On eD riv e\D oc um en ts\ ar ch ite ktu ra P

LC

\P ro jec ts\

_G

RP

S

Un ion

H igh

S ch oo l H ea lth

C en ter \R ev it\G

RP

S

Un ion

H S

Tr em on t B lvd C lin ic_ v3 .rv t

As indicated

G R

A N

D R

A P

ID

S

P U

B

LI

C S

C H

O O

LS

U N

IO

N

H S

H E

A

LT

H C

E N

TE

R

R E

N O

V A

TI

O

N S

2 JUNE 2025

T R

E M

O N

T B

LV

D

N W

, G R

A N

D R

A P

ID

S

M I 4

BIDS AND PERMITS

NO. DATE DESCRIPTION

SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"

STACKING REFRIGERATOR AND FREEZER. PROVIDE GFCI CIRCUIT BREAKER.

ALL RECEPTACLES ABOVE COUNTER SHALL BE GFCI PROTECTED. REUSE EXISTING CIRCUITS.

RELOCATE EXISTING SMOKE DETECTOR.

NO WORK IN THIS AREA.

REUSE EXISTING CIRCUITS FOR NEW DEVICES. PROVIDE NEW BREAKERS FOR CIRCUITS

REQUIRING GFCI BREAKERS.

POWER KEYNOTES: GENERAL POWER NOTES:

1. ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITH PUBLIC SPACES WHERE CHILDREN CAN

BE FOUND SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES SCHOOLS,

HOTELS, CLINICS, OUTPATIENT FACILITIES, PLACES OF WAITING AND ALL COMMON USE AREAS

(CORRIDORS, GYM, MUSIC ETC.).

2. FIRE ALARM (FA) DEVICES, IF SHOWN, ARE DIAGRAMMATIC IN NATURE ONLY AND ARE INTENDED

ONLY TO COMMUNICATE MAJOR SYSTEM COMPONENTS AND APPROXIMATE LOCATIONS. FULL

FA DRAWINGS TO BE DELEGATED DESIGN AND SHALL INCLUDE ALL SYSTEM COMPONENTS,

CALCULATIONS AND LOCATIONS.

3. ADD FIRE ALARM DEVICES AS SHOWN ON PLANS. CONNECT TO EXISTING SYSTEM. MATCH

EXISTING DEVICES.

4. ADDED FIRE ALARM DEVICES REQUIRE RECERTIFICATION OF SYSTEM.

5. FIELD VERIFY EXISTING PANEL D7. EXISTING PANEL SCHEDULE DOES NOT LABEL ALL CIRCUITS.

REMOVE EXISTING DEVICES IN WALLS TO BE REMOVED. PULL WIRING TO ABOVE WORK

SPACE. REUSE FOR NEW DEVICES.

REMOVE OLD COLOR BUTTON PANEL AND TURN OVER TO CLINIC MANAGER.

EXISTING SMOKE DETECTORS TO REMOVED. MOVE AS REQUIRED.

DEMOLITION POWER KEYNOTES:

FI

R

S T

FL

O

O R

A N

D D

E M

O

LI

TI

O

N P

LA

N

S

- P

O W

E R

P :\2

5\

G R

P S

U ni on H

S C lin ic

\W or ki ng

D ra w in gs \2

E

1.

dw g, /2 /2

3:

:2

P M

, m de lo

GRPS Union HS Tremont Blvd Clinic_v3
Sheets
A-1 - FIRST FLOOR AND DEMOLITION PLANS, ROOM FINISHES
A-2 - FIRST FLOOR REFLECTED CEILING PLAN
A-3 - DOOR SCHEDULE, DETAILS, AND ELEVATIONS
G-1 - CODE COMPLIANCE PLANS
T-1 - TITLE DRAWING
2 JUNE 25 GRPS Union HS Tremont Blvd Clinic COMBINED
Sheets
T-1 - TITLE DRAWING
G-1 - CODE COMPLIANCE PLANS
A-1 - FIRST FLOOR AND DEMOLITION PLANS
A-2 - FIRST FLOOR REFLECTED CEILING AND DEMOLITION PLANS
A-3 - DOOR SCHEDULE, DETAILS, AND ELEVATIONS

File details come from the government source that posted it. Updated .