This document is a set of construction drawings and specifications for the Spillway Bridge Concrete Repairs project at the Garrison Dam in North Dakota. The key details are:
The project involves concrete repairs to the Garrison Dam Spillway Bridge, including repairing spalls, deterioration, and replacing missing railing. The repairs are categorized into 8 distinct items, with detailed descriptions, locations, and required materials specified. The concrete repair materials must meet certain NDDOT and ACI standards. Traffic control requirements are outlined, including maintaining at least one 12-foot wide lane during the work. The solicitation number is W9128F24B0013, issued by the U.S. Army Corps of Engineers Omaha District, with a site visit scheduled for August 2. The drawings and specifications provide the detailed technical requirements for bidders to respond to this federal contract opportunity.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bid Abstract.pdf | ||
| W9128F24B0013A0003 Step Two Amendment.pdf | ||
| W9128F24B0013 Garrison Spillway Bridge Concrete Repairs Specs.pdf | ||
| W9128F24B0013 Amedment.pdf | ||
| GR00114 - STEP ONE -part-7.pdf | ||
| GR00114 - STEP ONE-_Part5.pdf | ||
| GR00114 - STEP ONEPart4.pdf | ||
| GR00114 - STEP ONE-Part3.pdf | ||
| GR00114 - STEP ONE-Part2.pdf | ||
| W9128F24B0013 Solicitation.pdf | ||
| GR00114 - STEP ONE part-6.pdf | ||
| W9128F24B0013 Garrison Spillway Bridge Concrete Repairs Specs.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A N
S I
D
S P
IL
L
W A
Y B
R
ID
G E
C O
N C
R E
T E
R E
P A
IR
S
G A
R R
IS
O
N D
A M
N
O R
T H
D A
K O
T A
W
F
/0
/2
O M
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
IC
T
F
IL
E
N U
M B
E R
F
IL
E N
A M
E
S L
IN
D
G R
E
C
V E
R
I N
D E
X
G-001
Z
M
IC
H K
A
S L
IN
D
G R
G R
G
-0 .d g n
Z
M
IC
H K
P
D
:0
:2
A
M
/9 /2
G R
G
-0
.d
SPILLWAY BRIDGE CONCRETE REPAIRS
GARRISON DAM, NORTH DAKOTA
W9128F240013
07/08/2024
OMAHA DISTRICT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S T
E P
O N
E of Engineers
US Army Corps
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
S
IL
L
W A
Y B
R
ID
G E
C O
N C
R E
T E
R E
P A
IR
S
G A
R R
IS
O
N D
A M
N
O R
T H
D A
K O
T A
W
F
/0
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
S L
IN
D
G R
B
B R
E V
IA
T
IO
N
S
G-002
Z
M
IC
H K
A
S L
IN
D
G R
G
-0 .d
Z
M
IC
H K
P
D
:0
:4
A
M
/9 /2
G R
G
-0
.d g n
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S T
E P
O N
E
CONTRACTORCONTR
CONTINUE CONT
CONSTRUCTIONCONSTR
CONNECTCONN
CONCRETECONC
COMPARTMENTCOMPT
COMBUSTIONCOMB
COMMONCOM
COLUMNCOL
CARBON DIOXIDECO2
CLEANOUTCO
COUNTERCNTR
CORNERCNR
CONDUCTIVE NEOPRENE LATEXCNL
CONDUITCND
CONCRETE MASONRY UNITCMU
COMPOSITECMPST
CORRUGATED METAL PIPECMP
CENTIMETER(S)cm
CLEAR WIRED GLASSCLWG
CLEAR(ANCE)CLR
CLOSURECLOS
CLOSETCLO
CONTRACT LIMIT LINECLL
CLEAR GLASSCLGL
CEILING HEIGHTCLG HT
CEILINGCLG
CENTER LINECL
CIRCUIT BREAKERCKT BRKR
CIRCUITCKT
CONSTRUCTION JOINTCJ
CONTROL JOINTCJ
CIRCULARCIRC
CAST-IN-PLACECIP
CURB INLETCI
CAST IRONCI
CHROME PLATEDCHR PL
CHECKCHK
CHIMNEYCHIM
CHAMFERCHFR
CHALKBOARDCH BD
CORNER GUARDCG
CUBIC FEET PER MINUTECFM
COUNTERFLASHINGCFLG
CONDUCTIVE FLOORINGCFI
CERAMICCER
CEMENT PLASTERCEM PLAS
CEMENTCEM
COVER ELEVATIONCE
CLOSED CIRCUIT TELEVISIONCCTV
CUBICLE CURTAIN TRACKCCT
CATCH BASINCB
CAPACITYCAP
CABINETCAB
BOTH WAYSBW
BUILT-UP ROOFINGBUR
BETWEENBTWN
BTU PER HOURBtuH
BRITISH THERMAL UNITBtu
BASEMENTBSMT
BOTH SIDESBS
BRONZEBRZ
BRACKETBRKT
BRICKBRK
BEARING PLATEBRG PL
BEARINGBRG
BRIDGINGBRDG
BRACINGBRCG
BACK PLASTER(ED)BP
BOTTOMBOT
BOTTOM OFBO
BENCHMARKBM
BELOWBLW
BUILDINGBLDG
BUILDING LINEBL
BED JOINTBJT
BITUMINOUSBITUM
BEVELBEV
BRICK EXPANSION JOINTBEJ
BOUNDARYBDRY
BOARDBD
BOOKCASEBC
BULLETIN BOARDBB
ACOUSTICAL WALL TREATMENTAWT
AMERICAN WIRE GAUGEAWG
AVERAGEAVG
AUTOMATICAUTO
ACOUSTICAL TILE CEILINGATC
ASPHALTASPH
ABOVE SUSPENDED CEILINGASC
ASBESTOSASB
AMERICAN REFRIGERATION INSTITUTEARI
ARCHITECTARCH
APPROXIMATEAPPROX
APPROVEDAPPD
AMERICAN NATIONAL STANDARDS INSTITUTEANSI
ANODIZEANOD
AMPEREAMP
AMBIENTAMB
ALUMINUMALUM
ALTERNATEALT
ACTIVE LEAFA.L.
AMERICAN INSTITUTE OF STEEL CONSTRUCTIONAISC
AMPERE INTERRUPTING CAPACITYAIC
AREA INLETAI
AIR HANDLING UNITAHU
ANCHOR AHR
AGGREGATEAGGR
ABOVE FINISHED FLOORAFF
AUTOMATIC DOOR OPERATORADO
ADJACENT, ADJOINING, ADJUSTABLEADJ
ADHESIVEADH
ADDENDUMADDM
ACOUSTICAL CEILING TILEACT
ACOUSTICACST
ALUMINUM CABLE STEEL REINFORCEDACSR
ACCESS PANELACS PNL
ACCESS DOORACS DR
ACRYLIC PLASTICACR
AMERICAN CONCRETE INSTITUTEACI
ACCESSIBLEACC
ALTERNATING CURRENTAC
ABOVEABV
ANCHOR BOLTAB
AIR CONDITIONING UNITA/C UNIT
AIR CONDITIONINGA/C
ANGLEL
FLOORFLR
FLASHINGFLASH
FLUSH JOINTFJT
FIXTUREFIXT
FINISH FLOORFIN FLR
FINISHFIN
FIGUREFIG
FLAT HEAD WOOD SCREWFHWS
FIRE HOSE STATIONFHS
FIRE HOSE RACKFHR
FLAT HEAD MACHINE SCREWFHMS
FIRE HOSE CABINETFHC
FLAT HEADFH
FIRE HYDRANTFH
FIBERGLASSFGL
FACTORY FINISHFF
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHER BRACKETFEB
FIRE EXTINGUISHERFE
FOUNDATIONFDTN
FIRE DAMPERFDMPR
FLOOR DRAINFD
FAN COIL UNITFCU
FLOOR CLEANOUTFCO
FLOOR CONSTRUCTION JOINTFCJ
FACINGFCG
FACE BRICKFC BRK
FOOT CANDLEFC
FIRE BRICKF BRK
FRESH AIR INTAKEFAI
FIRE APPARATUS CLOSETFAC
FRESH AIRFA
FIRE ALARMFA
FAHRENHEITF
EXTERIOREXT
EXPANSION BOLTEXP BT
EXPOSEDEXP
EXPANSIONEXP
EXISTINGEXST
EXHAUST AIREXH A
EXHAUSTEXH
EXCAVATEEXC
ENTERING WATER TEMPERATUREEWT
ELECTRIC WATER COOLEREWC
ESTIMATE(D)EST
ESCALATORESCAL
EQUIPMENTEQUIP
EQUALEQ
EPOXY COATINGEPY
EXPLOSION PROOFEPRF
ELECTRICAL PANELBOARDEP
ENTRANCE, ENTERINGENTR
ENCLOSE(URE)ENCL
EMERGENCYEMER
ESTIMATED MAXIMUM DEMANDEMD
EXPANDED METAL EM
ELECTRICELEC
ELEVATION - GRADE OR BUILDINGEL
EXPANSION JOINTEJ
EACH FACEEF
ENTERING AIR TEMPERATUREEAT
EACHEA
EASTE
DIRECT EXPANSIONDX
DUMBWAITERDWTR
DRAWERDWR
DOWELSDWLS
DRAWINGDWG
DOVETAIL DVTL
DRAIN TILEDT
DOWNSPOUTDS
DOUBLE STRENGTH (GLASS)DS
DOOR CLOSERDR CL
DRAINBOARDDRB
DRAINDR
DOORDR
DOWNDN
DEMOUNTABLEDMT
DAMPERDMPR
DAMPPROOFINGDMPF
DEAD LOADDL
DIVISIONDIV
DISTRIBUTION PANELDISTR PNL
DISPENSERDISP
DISCONNECTDISC
DIMENSIONDIM
DIAGONALDIAG
DIAMETERDIA
DUCT HEATERDH
DOUBLE HUNGDH
DRINKING FOUNTAINDF
DETAILDET
DEPARTMENTDEPT
DEPRESSIONDEPR
DEMOLITIONDEMO
DEGREEDEG
DUMMY CONTROL JOINTDCJT
DOWELED CONTROL JOINTDCJ
DOUBLE ACTING DOORDBL ACT DR
DOUBLEDBL
DRY BULBDB
DATUMDAT
PENNY (AS IN NAIL - 10D)d
CYLINDERCYL
COLD WATERCW
CONDUCTIVE VINYL HOMOGENEOUS (SHEET TYPE)CVH
CEILING VENTCV
CUBIC YARDSCU YD
CABINET UNIT HEATERCUH
CUBIC FEETCU FT
COPPERCu
CONDENSING UNITCU
CENTERCTR
CENTER TO CENTERC TO C
CURRENT TRANSFORMERCT
CERAMIC TILECT
CASEMENTCSMT
COUNTERSUNKCSK
CAST STONECS
COURSE(S)CRS
CROSS GRAINCRG
CORROSIVE RESISTANT STEELCRES
CIRCUMFERENCECRCMF
CARPETCPT
COMPRESSIBLECPRS
COVERCOV
CORRIDORCORR
LAG BOLTLB
LAVATORYLAV
LAUNDRYLAU
LEAVING AIR TEMPERATURELAT
LAMINATELAM
LADDERLAD
LABORATORYLAB
KEYWAYKWY
KILOWATTkW
KILOVOLT AMPERES REACTIVEkVAR
KILOVOLT AMPERESkVA
KILOVOLTSkV
KILOMETERkm
KICKPLATEKPL
KNOCKOUT PANELKOP
KITCHENKIT
KILOPOUND (1000 POUNDS)KIP
JOINTJT
JOISTJST
JUNCTIONJCT
JUNCTION BOXJ-BOX
JANITOR’S CLOSETJAN CLO
INSIDE PIPE SIZEI.P.S.
IRON PIPE SIZEIPS
IRON PIPEIP
INVERTINV
INTERMEDIATEINTM
INTERIORINT
INSULATIONINSUL
INSULATING FILLINSF
INCLUDEDINCL
INCINERATORINCIN
INCHIN
INTERLOCKILK
ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAIESNA
INSIDE DIAMETERID
INTERCOMIC
HERTZHz
HYDRAULICHYDR
HEATING, VENTILATING AND AIR CONDITIONINGHVAC
HEATERHTR
HEATINGHTG
HEIGHTHT
HOUSEKEEPINGHSKPG
HIGH-STRENGTH GYPSUM PLASTERHSGYP
HIGH STRENGTHHS
HOURHR
HIGH POINTHPT
HORSEPOWERHP
HIGH PRESSUREHP
HORIZONTALHORIZ
HANDRAILHNDRL
HOLLOW METALHM
HOOK(S)HK
HANDHOLEHH
HEXAGONHEX
HIGH EARLY-STRENGTH CEMENTHES
HARDWOODHDWD
HARDWAREHDW
HEADERHDR
HEAD JOINTHD JT
HARDBOARDHDBD
HEAVY DUTYHD
HEADHD
HANDICAPPEDHCP
HALON CONTAINMENT DAMPERHCD
HOLLOW COREHC
HOSE BIBBHB
GYPSUM PLASTERGYP PLAS
GYPSUM BOARDGYP BD
GYPSUMGYP
GLAZED WALL TILEGWT
GROUTGT
GLAZED STRUCTURAL UNITSGSU
GLAZED STRUCTURAL TILEGST
GRATINGGRTG
GRADE LINEGR LN
GRANITEGRAN
GYPSUM TILEGPT
GALLONS PER MINUTEGPM
GOVERNMENTGOVT
GROUNDG
GLAZED CONCRETE MASONRY UNITSGLZ CMU
GLAZINGGLZ
GLASS FIBERGLF
GLASS BLOCKGL BLK
GLASSGL
GASKET(ED)GKT
GALVANIZED IRON PIPEGIP
GALVANIZED IRONGI
GOVERNMENT-FURNISHED EQUIPMENT CONTRACTOR INSTALLEDGFE/CI
GOVERNMENT-FURNISHED EQUIPMENTGFE
GROUND FAULT CIRCUIT INTERRUPTERGFCI
GROUND FACEGF
GENERALGEN
GENERAL CONTRACTORGC
GRAB BARGB
GALVANIZED STEELGALV STL
GALVANIZEDGALV
GALLON(S)GAL
GAGEGA
NATURAL GASG
FABRIC WALL COVERINGFWC
FIRE WATERFW
FUTUREFUT
FURRINGFURG
FOOTINGFTG
FEETFT
FASTEN(ER)FSTNR
FULL SIZEFS
FIRE-RETARDANTFRT
FRAMINGFRMG
FORGEDFRG
FRAMEFR
FIRE RESISTANT FR
FEET PER MINUTEFPM
FIREPROOFFP
FIRE PARTITIONFP
FACE OF STUDFOS
FACE OF MASONRYFOM
FACE OF FINISHFOF
FACE OF CONCRETEFOC
FENCEFN
FLUORESCENTFLUOR
FLOOR PLATEFLR PL
FLOORINGFLG
FLEXIBLEFLEX
PERFORATE(D)PERF
PEDESTALPED
PAVEMENT DRAINPD
CEMENT PLASTER (PORTLAND)PCP
POUNDS PER CUBIC FOOTPCF
PRECAST CONCRETEPCC
PIECEPC
PUSH BUTTON STATIONPBS
PARTICLE BOARDPBD
PANIC BARPB
PARALLELPAR
PUBLIC ADDRESSPA
POLEP
OBSCURE WIRED GLASSOWGL
OUTSIDE SCREW AND YOKEOS & Y
OPERATIONSOPS
OPAQUEOPQ
OPPOSITEOPP
OPENINGOPNG
OPPOSITE HANDOPH
OVALHEAD WOOD SCREWOHWS
OVALHEAD MACHINE SCREWOHMS
OVERHEADOH
OBSCURE GLASSOGL
OFFICEOFC
OUTSIDE DIAMETEROD
ON CENTER EACH WAYOCEW
ON CENTEROC
OBSERVATION WINDOWOBW
OBSCUREOBSC
OUTSIDE AIROA
NOT TO SCALENTS
NOT REQUIREDN’’REQD
NOISE REDUCTION COEFFICIENTNRC
NOISE REDUCTIONNR
NOMINALNOM
NUMBERNO
NORMALLY OPENNO
NONMETALLICNM
NEOPRENE LATEXN.L.
NAILABLENL
NOT IN CONTRACTNIC
NICKELNi
NATIONAL FIRE PROTECTION ASSOCIATIONNFPA
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNEMA
NATIONAL ELECTRICAL CODENEC
NORMALLY CLOSEDNC
NATURALNAT
NORTHN
MULLIONMULL
MOVABLEMVBL
METALMTL
METAL FURRINGMTFR
MOUNTEDMTD
MOUNTMT
METAL THRESHOLDMT
MACHINE SCREWSMS
METAL ROOF DECKINGMRD
MARBLE BASEMRB
MOP RECEPTORMR
MOVABLE PARTITIONMP
MOTORMOT
MODIFIEDMOD.
MODULARMOD
MASONRY OPENINGMO
MATERIAL NOT IN CONTRACT (INSTALLATION BY CONTRACTOR)MNIC
MILLIMETER(S)mm
MILLWORKMLWK
MOULDINGMLDG
MONOLITHICML
METAL LATHML
MISCELLANEOUSMISC
MIRRORMIRR
MINIMUMMIN
MALLEABLE IRONMI
MANHOLEMH
MATTE-GLAZED TILEMGT
MOTOR GENERATORMG
MANUFACTURERMFR
MANUFACTURINGMFG
METAL FLOOR DECKINGMFD
METAL EDGE STRIPMES
MEMBRANEMEMB
MEDIUMMED
MECHANICAL ROOMMECH RM
MECHANICALMECH
METAL DIVIDER STRIPMDS
METAL-CASED OPENINGMCO
MASONRY CONTROL JOINTMCJ
MEDICINE CABINETMC
MEMBERMBR
MACHINE BOLTSMB
MAXIMUMMAX
MATERIAL(S)MATL
MASONRYMAS
MACHINEMACH
MATCHED AND BEADEDM&B
METER(S)m
LEAVING WATER TEMPERATURELWT
LIGHTWEIGHT CONCRETELWC
LOUVERLVR
LIGHTNINGLTNG
LIGHTINGLTG
LIGHTWEIGHTLT WT
LIGHTLT
LAWN SPRINKLERLS
LIVING ROOMLR
LOW POINTLPT
LIGHTPROOF LOUVERLPL
LIGHTPROOF DOORLPD
LIGHTPROOFLP
LONGITUDINALLONG
LINTELLNTL
LIMESTONELMST
LUMENLM
LEAD-LINED DOORLLD
LIVE LOADLL
LOCKERLKR
LINEARLIN
LEFT HAND(ED)LH
LENGTHLG
LOADINGLDG
LOADLD
LIGHT CONTROLLC
LUMBERLBR
LABELLBL
POUNDLB
SOUNDPROOF DOORSPD
SPECIALSPCL
SPACERSPC
SHUT OFF VALVESOV
SHEET METAL SCREWSSMS
SHEET METALSM
SLEEVESLV
SEALANTSLNT
SKYLIGHTSKLT
STEEL JOIST INSTITUTESJI
SIMILARSIM
SHELVINGSHV
SHEATHINGSHTHG
SHEETSHT
SHOULDERSHLDR
SHEET GLASSSG
STRUCTURAL FACING UNITSFU
STRUCTURAL FACING TILE UNITSFTU
SAFETY GLASSSFGL
SEQUENCESEQ
SECTIONSECT
STEEL DOOR INSTITUTESDI
STORM DRAINSD
STRUCTURAL CLAY TILESCT
SCREENSCRN
SCHEDULESCHED
SOLID CORESC
SECURITY BARSS.B.
SPLASH BLOCKSB
SUPPLY AIRSA
SOUTHS
RAINWATER CONDUCTORRWC
RIVETRVT
REVERSERVS
RUBBER TILE FLOORRTF
RAISED PATTERN RUBBER TILERPRT
REVOLUTIONS PER MINUTERPM
RETRACTABLE PARTITIONRP
RIGHT OF WAYROW
ROUGH OPENINGRO
ROUNDRND
ROOMRM
RAILINGRLG
RACKRK
ROOF HATCHRH
RIGHT HANDRH
RELATIVE HUMIDITYRH
ROOFINGRFG
REVISIONREV
RETURNRET
RESILIENTRESIL
REQUIREDREQD
REMOVE(ABLE)REM
REINFORCEREINF
REGLETREG
REGISTERREG
REFRIGERATIONREFR
REFLECTREFL
REFERENCEREF
RECTIFIERRECT
RECREATION ROOMREC ROOM
RECEPTACLERECPT
RIGID INSULATIONRDG INS
ROOF DRAINRD
RECEIVERRCVR
REINFORCED CONCRETE PIPERCP
REMOTE CONTROLRC
RUBBERRBR
RUBBLE STONERBL
RUBBER BASE, RESILIENT BASERB
RETURN AIR REGISTERRAR
RETURN AIR GRILLERA GR
RABBETEDRAB
RETURN AIRRA
RISERR
RANGER
RADIUSR
QUANTITYQTY
QUARTER ROUND1/4 RND
QUARTERQTR
QUARTQT.
QUARRY TILEQT
PASS WINDOWPW
PAVINGPVG
POLYVINYL CHLORIDEPVC
PAVEDPV
PAPER TOWEL RECEPTACLEPTR
PARTITIONPTN
PAPER TOWEL DISPENSERPTD
POST-TENSIONED CONCRETEPT CONC
POINTPT.
PNEUMATIC TUBEPT
POUNDS PER SQUARE INCHPSI
POUNDS PER SQUARE FOOTPSF
PRESTRESSED CONCRETEPS CONC
PRESSED STEELP.S.
PIPE SPACEPS
PRESSURE-REGULATING VALVEPRV
PROJECTPROJ
PARKINGPRKG
PREFORMEDPREFMD
PREFINISHEDPREFIN
PREFABRICATE(D)PREFAB
PAIRPR
PARTS PER MILLIONPPM
POLISHED PLATE GLASSPPGL
PORTABLEPORT
PORCELAINPORC
POLISHEDPOL
PAINT(ED)PT
PANELPNL
PLYWOODPLYWD
PLATE GLASSPL GL
PILINGPLG
POUNDS PER LINEAR FOOTPLF
PLUMBINGPLBG
PLATFORMPLAT
PLASTERPLAS
PLASTIC LAMINATEPLAM
PROPERTY LINEPL
PLATEPL
POST INDICATING VALVEPIV
PREFAB ISOLATION POWER UNITPIPU
POINT OF INTERSECTIONPI
PHARMACYPHAR
PHASEPH
PERIMETERPERIM
YARD DRAINYD
YARDYD
TRANSFORMERXFMR
WELDED WIRE REINFORCEMENTWWR
WELDED WIRE MESHWWM
WELDED WIRE FABRICWWF
WALL TO WALLW/W
WIDTHWTH
WEIGHTWT
WAINSCOTWSCT
WASTE STACKW.S.
WATERSTOPWS
WARDROBEWRB
WASTE RECEPTACLEWR
WORKING POINTWP
WEATHERPROOFWP
WATERPROOF(ING)WP
WITHOUTW/O
WIRE MESHWM
WORK SHOPWKSH
WROUGHT IRONWI
WATT-HOUR METERWHM
WHEEL BUMPERWHB
WATER HEATERWH
WALL HUNGWH
WIRED GLASSWGL
WIDE FLANGEWF
WINDOWWDW
WASTE DISPOSERWDSP
WOOD DOORWD
WOODWD
WOOD-CASED OPENINGWCO
WHEELCHAIRW/C
WATER CLOSETWC
WOOD BLOCKINGWBL
WET BULBWB
WITHW/
WESTW
VINYL WALL COVERINGVWC
VENT THRU ROOFVTR
VOLTAGE TRANSFORMERV.T.
VENT STACKVS
VERMICULITEVRM
VAPOR RETARDERVR
VOLUMEVOL
VENEERVNR
V-JOINT(ED)VJ
VINYL HOMOGENEOUSVH
VERTICAL GRAINVG
VINYL FABRICVF
VESTIBULEVEST
VERTICALVERT
VENTILATOR(TION)VENT
VAULT DOORVD
VITRIFIED CLAY TILEVCT
VINYL COMPOSITION TILEVCT
VINYL BASEVB
VARNISHVAR
VOLTV
UNIT VENTILATORUV
UTILITYUTIL
URINALUR
UNINTERRUPTABLE POWER SUPPLYUPS
UNFINISHEDUNFIN
UNEXCAVATEDUNEX
UNDERWRITERS LABORATORIESUL
UNIT HEATERUH
UNDERGROUNDUGND
UNIT COOLERUC
TYPICALTYP
TELEVISIONTV
THERMOSTATTSTAT
TRANSVERSETRANS
TRANSOMTRANS
TOILET PARTITIONTPTN
TOILET PAPER DISPENSERTPD
TOP OF WALLTOW
TOP OF STEELTOS
TOP OF SLABTOS
TOPOGRAPHYTOPO
TOLERANCETOL
TOP OFTO
TACKSTRIPTKS
TACKBOARDTK BD
THRESHOLDTHRES
THICK(NESS)THK
TRUSS HEADTH
TOGGLETGL
TONGUE AND GROOVET&G
TERMINALTERM
TERRAZZOTER
TEMPORARYTEMP
TEMPERATURETEMP
TELEPHONETEL
TERRA COTTATC
TOWEL BARTB
TANGENTTAN
TREADT
SYSTEMSYS
SYNTHETICSYNTH
SYMMETRICALSYMM
SWITCHBOARDSWBD
SWITCHSW
SHEET VINYL SV
SUSPENDEDSUSP
SUBFLOORSUB FL
STAIRWAYSTWY
STRUCTURALSTRUCT
STRINGERSTR
STATIC PRESSUREST PR
STORAGESTOR
STEELSTL
SEATINGSTG
STANDARDSTD
STATIONSTA
STAINLESS STEELSST
STANDING SEAM (ROOF)SS
SERVICE SINKSS
SHELF AND RODS&R
SQUARE HEADSQHD
SQUARESQ
SPEAKERSPKR
SPACE HEATERSPH
SPECIAL FINISHSP FIN
SOUNDPROOFSPF
SPECIFICATIONSPEC
ABBREVIATIONS
S
IL
L
W A
Y B
R
ID
G E
C O
N C
R E
T E
R E
P A
IR
S
G A
R R
IS
O
N D
A M
N
O R
T H
D A
K O
T A
W
F
/0
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
F
IL
E N
A M
E
S D
E N
N
IN
R U
C T
U R
A L
N O
T E
S
S-001
J O
S B
O R
N
S D
E N
N
S
-0 .d
J
O
S B
O
P
D
:5
:3
P
M
/8 /2
G R
S
-0
.d g n
GARRISON DAM SPILLWAY BRIDGE
NUMBERING
BRIDGE SPAN
NUMBERING
MONOLITH
NUMBERING
TAINTER GATE
SPILLWAY BRIDGE
GARRISON DAM
BENEATH BRIDGE
ACCESS FOR CATWALK
BENEATH BRIDGE
ACCESS FOR CATWALK
2 2
BENEATH BRIDGE
ACCESS FOR CATWALK
BENEATH BRIDGE
ACCESS FOR CATWALK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S T
E P
O N
E
SPECIFICATION SECTION 03 01 00 CONCRETE REHABILITATION FOR REQUIREMENTS.
FOR REPAIR 2, 4, AND 5, THE REPAIR MATERIAL SHALL BE A BAGGED CONCRETE MIX THAT MEETS THE REQUIREMENTS IN C.4.
REHABILITATION FOR ADDITIONAL REQUIREMENTS.
SPECIFICATION SECTION 802 FOR CONCRETE CLASS AAE. SEE SPECIFICATION SECTION 03 01 00 CONCRETE
FOR REPAIRS 1 AND 3, THE CONCRETE REPAIR MATERIAL SHALL BE CONCRETE THAT MEETS THE NDDOT STANDARD C.3.
REINFORCEMENT BAR IN BOTH COMPRESSION AND TENSION.
MECHANICAL SPLICE CONNECTORS SHALL TRANSFER 125 PERCENT OF THE MINIMUM YIELD STRENGTH OF THE C.2.
CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH ASTM A615, GR. 60 KSI.C.1.
C. REPAIR MATERIALS:
WITH BRACKET TO MATCH AS-BUILT CONDITIONS (SEE "BRIDGE RAILING" DETAIL ON S-911).
REPAIR 8: REPLACE MISSING RAILING SUPPORT ON DOWNSTREAM PARAPET IN SPAN 15. SEE PHOTO 27 ON S-203. REPLACE A.8.
NORTH NEAR MONOLITH 26. SEE PHOTOS 25 AND 26 ON S-203.
REPAIR 7: REPAIR DISCONNECTED METAL RAILING IN SPAN 7 PLAN SOUTH PARAPET NEAR MONOLITH 8 AND SPAN 25 PLAN A.7
REPAIR 5.
SEALANT. SEE PHOTO 24 ON S-203. THERE ARE 120 TOTAL LOCATIONS INCLUDING THE LOCATIONS WITH SPALL REPAIRS IN
REPAIR 6: REMOVE LEAD CAULK AT ALL METAL RAILING INTERFACES WITH CONCRETE PARAPET AND REPLACE WITH JOINT A.6.
MONOLITHS 16 (PLAN SOUTH) AND 21 (PLAN SOUTH). SEE E3/S-500 AND PHOTOS 22 ON S-202 AND 23 ON S-203.
RUST AND COAT END OF METAL RAILING NEAR CONCRETE INTERFACE. SPALLS ARE LOCATED AT EXPANSION JOINTS OVER
REPAIR 5: REPAIR SPALLS AT METAL RAILING INTERFACE WITH CONCRETE PARAPET. REPLACE PIPE SLEEVE AND REMOVE A.5.
(e). SPAN 27 IN PLAN NORTH SIDEWALK NEAR MONOLITH 28 - PHOTO 21 ON S-202
(d). SPAN 25 IN PLAN NORTH SIDEWALK NEAR MONOLITH 26 - PHOTO 20 ON S-202
(c). SPAN 20 IN PLAN NORTH SIDEWALK NEAR MONOLITH 21 - PHOTO 19 ON S-202
(b). MONOLITH 9 IN PLAN NORTH PARAPET AT TOP OF PIER - PHOTO 18 ON S-202
(a). WEST ABUTMENT PLAN SOUTH SIDEWALK - PHOTO 17 ON S-202
REPAIR 4: REPAIR SPALLS AT THE LOCATIONS LISTED BELOW. SEE A15/S-500 FOR TYPICAL SPALL REPAIR.A.4.
S-202.
REPAIR 3: REPAIR DETERIORATED PLAN NORTH SIDEWALK IN SPAN 21 NEAR MONOLITH 21. SEE J3/S-500 AND PHOTO 16 ON A.3.
(g). MONOLITH 29 - FIRST GROUT POCKET FROM PLAN SOUTH AT WEST END OF SPAN 29 - PHOTO 15
(f). MONOLITH 22 - SECOND GROUT POCKET FROM PLAN SOUTH AT WEST END OF SPAN 22 - PHOTO 14
PHOTOS 11, 12, AND 13
(e). MONOLITH 20 - FIRST, SECOND, AND FOURTH GROUT POCKET FROM PLAN SOUTH AT WEST END OF SPAN 20 -
PHOTOS 8, 9, AND 10
(d). MONOLITH 18 - SECOND, FOURTH, AND FIFTH GROUT POCKET FROM PLAN SOUTH AT WEST END OF SPAN 18 -
PHOTOS 5, 6, AND 7
(c). MONOLITH 17 - FIRST, SECOND, AND FIFTH GROUT POCKET FROM PLAN SOUTH AT WEST END OF SPAN 17 -
(b). MONOLITH 16 - FIRST GROUT POCKET FROM PLAN SOUTH AT WEST END OF SPAN 16 - PHOTO 4
(a). MONOLITH 6 - FIRST GROUT POCKET FROM PLAN SOUTH AT WEST END OF SPAN 6 - PHOTO 3
PHOTO 15 ON S-202.
AT THE LOCATIONS LISTED BELOW. SEE G9/S-500 AND PHOTOS 3 THRU 6 ON S-200, PHOTOS 7 THRU 14 ON S-201, AND
REPAIR 2: REPAIR SPALLS BENEATH BRIDGE DECK AT POST-TENSIONING GROUT POCKETS IN THE DECK STIFFENER BEAMS A.2.
200.
REPAIR 1: REPAIR PLAN NORTH CONCRETE PARAPET AND SIDEWALK IN SPAN 31. SEE G15/S-500 AND PHOTOS 1 AND 2 ON S-A.1.
A. SUMMARY OF STRUCTURAL WORK:
PROJECT LOCATION MAP
PROJECT AREA MAP
LAKE SAKAKAWEA
HWY 200
H W
Y 200
AREASTA
G
SP
ILL
W
AY
ACCES
S
ROAD
CONCRETE JERSEY BARRIERS TO PROTECT VEHICLES DURING CONCRETE PARAPET REPAIRS.
COMMENCING. THE TRAFFIC CONTROL PLAN SHALL BE IN ACCORDANCE WITH NDDOT STANDARD SPECIFICATIONS. PROVIDE
WORK. SUBMIT A TRAFFIC CONTROL PLAN TO THE GOVERNMENT AND NDDOT A MINIMUM OF 40 DAYS PRIOR TO WORK
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING TRAFFIC CONTROL FOR THE DURATION OF B.4.
SHALL BE PROVIDED TO ACCOMMODATE AGRICULTURAL EQUIPMENT.
FOR THE DURATION OF THE WORK. DURING THE MONTHS OF APRIL THROUGH NOVEMBER, A MINIMUM LANE WIDTH OF 16 FT
BRIDGE WORK SHALL BE DONE IN ORDER SUCH THAT THE BRIDGE WILL HAVE ONE LANE OPEN (MINIMUM OF 12 FT WIDE) B.3.
PROJECT.
OF ANY DIMENSIONS AND DETAILS THAT AFFECT THE SATISFACTORY COMPLETION OF THE WORK REQUIRED FOR THIS
CONSTRUCTION PLANS. IT IS THE CONTRACTOR’S RESPONSIBILITY TO INSPECT AND VERIFY THE ACTUAL FIELD CONDITIONS ALL DETAILS AND DIMENSIONS OF THE EXISTING STRUCTURE CONTAINED IN THESE PLANS, ARE BASED ON THE ORIGINAL B.2.
SEE S-900 SERIES SHEETS FOR SPILLWAY BRIDGE RECORD DRAWINGS AND PLANS.B.1.
B. GENERAL NOTES:
SPILLWAY BRIDGE MONOLITH, SPAN, AND GATE NUMBERING (SEE ALSO S-901)
PHOTO OF SPILLWAY BRIDGE
11 12 13 14 15 16 17 18 19 20 21
10 11
12 13 14 15 16 17 18 19 20 21 22
G1
G2
G3 G4
G5 G6
G7 G8
G9 G10 G11 G12 G13 G14 G15 G16 G17 G18 G19
G20 G21
G22 G23
G24 G25
G26 G27
G28
SPILLWAY SLAB BELOW.
DRAINS AND FROM FALLING OFF THE BRIDGE WHETHER THAT BE INTO THE LAKE, ON TO THE CATWALK, OR ON TO THE
D.10. PREVENT CONSTRUCTION MATERIALS AND DEBRIS FROM CONSTRUCTION OPERATIONS FROM ENTERING STORM WATER
MEASUREMENT TO THE GOVERNMENT.
CORRODED REINFORCEMENT THICKNESS MEASUREMENTS AND A PLAN INDICATING THE LOCATION OF THE THICKNESS MEASURABLE SECTION LOSS DUE TO CORROSION. TAKE MEASUREMENTS AFTER REMOVAL OF THE CORROSION. SUBMIT THICKNESS MEASUREMENTS OF THE CONCRETE REINFORCEMENT SHALL BE TAKEN WHERE THERE ARE AREAS OF D.9.
COMPLETE, APPLY A CURING COMPOUND IN CONFORMANCE TO ASTM C309, TYPE 2.
CONCRETE SHALL BE WET CURED FOR 7 DAYS AFTER CONCRETE PLACEMENT. IMMEDIATELY AFTER WET CURING IS D.8.
THE PLANS. MATCH THE EXISTING CHAMFER IF CHAMFER DIFFERS.
ALL EXPOSED REPAIR MATERIAL CORNERS AND EDGES WILL BE CHAMFERED 3/4-INCH UNLESS NOTED OTHERWISE IN D.7.
PRIOR TO AND DURING REPAIR MATERIAL PLACEMENT.
ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND MAINTAINED SECURELY IN PLACE D.6.
APPROVED ALL EMBEDDED WORK, INCLUDE REINFORCEMENT.
NO REPAIR MATERIALS SHALL BE PLACED UNTIL THE CONTRACTING OFFICER'S REPRESENTATIVE HAS INSPECTED AND D.5.
EMBEDMENTS ARE PERMITTED.
NO CALCIUM CHLORIDE OR OTHER DELETERIOUS SALTS ARE PERMITTED IN REPAIR MATERIALS. NO ALUMINUM D.4.
A MINIMUM OF TWO BAR DIAMETERS SHALL BE PLACED BETWEEN PARALLEL REINFORCEMENT STEEL BARS.D.3.
USE 2-INCH CLEAR COVER ON ALL REINFORCING STEEL EXCEPT AS SHOWN OTHERWISE.D.2.
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
STANDARDS. REINFORCEMENT BARS SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP ALL CONCRETE OPERATIONS AND REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE LATEST ACI AND CRSI D.1.
D. CONSTRUCTION NOTES:
STRUCTURAL WORK "A" NOTES ON THIS SHEET.
- REFERS TO REPAIR # IN SUMMARY OF
| GENERAL | |
| G-001 | COVER & INDEX (1) |
File details come from the government source that posted it. Updated .