G1 JBMDL Dix Dual Food Burger King - Dunkin Donuts Image Update - 1760-22-00003 IFS Dwgs_10-18-2024.pdf
PDF 31 MB Posted
- Solicitation number
- GNFR-FC-DMC-24-21896
- Issued by
-
Department of Defense
About this file
This appears to be a drawing or design file based on the filename (ending in "IFS Dwgs") related to an image update project for a dual food facility at Joint Base McGuire-Dix-Lakehurst (JBMDL) in New Jersey. The project involves renovations to Building 5399, a 6,616 SF facility that will house both Burger King and Dunkin Donuts operations. The scope includes updating interior and exterior finishes, dining room fixtures, signage, exterior canopies and facades, upgrading the existing Burger King dual drive-through components, adding a new Dunkin Donuts drive-through, and installing a new AAFES marquee. The Dunkin Donuts portion will be provided as shell space for concessionaire renovation. The project is being managed by the Department of Defense with project number 1760-22-000003.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
MRF
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL QAI10/11/23
95% SUBMITTAL QAI03/12/24
QAI
100% SUBMITTAL QAI09/11/24
ISSUE FOR SOLICITATION QAI10/18/24
/1 6/
2:
:1
P
M
G-001
TITLE SHEET
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
ABBREVIATIONS
GENERAL NOTES PROJECT TEAM INDEX TO DRAWINGS
ARCHITECTURAL SYMBOLS
AAFES PROJECT MANAGER
NORTH ARROW
0 1 2 3 4 8 12
CENTER LINE
REVISION CLOUD
SCALE BAR
0'-0"
BENCHMARK
ELEVATION
SECTION
SHEET NUMBER
SECTION NUMBER
DETAIL BUBBLE
SHEET NUMBER
DETAIL NUMBER
xxxx x xxxx x xxxx
PXXX FINISH SCHEDULE
X REVISION
DATUM POINT
AFF HEIGHT TAGS
DOOR NUMBER
EQUIPMENT TAG
WALL TYPE TAG
+X-XX
XXX
XXXX
X
X APPLIED WALL
TREATMENT TAG
VICINITY MAP
ARCHITECT
MEP ENGINEER
SITE LOCATION
SITE LOCATION NO SCALE
SCOPE OF WORK
CONVERT:
SITE LOCATION NO SCALE
EXCHANGE PROJECT MANAGER:
EXCHANGE CONTRACTING OFFICER:
QUORUM ARCHITECTS:
GENERAL CONTRACTOR:
CIVIL ENGINEER
RESPONSIBILITY MATRIX
BLDG #5399
5399 BROIDY RD, JB-MDL, NJ 08640
ARMY AIR FORCE
EXCHANGE SERVICE
5399 BROIDY RD, JB-MDL, NJ 08640
BURGER KING TO DUAL FOOD FACILITY
5399 BROIDY RD, JB-MDL, NJ 08640
EXTERIOR:
1. Renovate the exterior from a Burger King into a New Dual Food facility.
A. Build new Burger King tower on building NE corner for Burger King signage B. Remove existing windows as indicated for Dunkin Donuts section of building.
C. Replace existing awnings with new horizontal canopies as indicated.
D. Repair and paint existing stucco as noted on the drawings. Paint trash enclosure to match building as noted.
E. Remove existing red Burger King LED band from building. Remove circuits back to main panel.
F. Remove Burger King signage on SE corner tower and square off parapet.
G. Replace all existing parapet cap as indicated.
H. Add Burger King signage "Flame Grilling Since 1954" on East wall near
Northeast corner.
I. Add emergency egress door and storefront at southeast side of dining room.
2. Close site entrance from Broidy Road.
3. Install new concrete drive-through lane and curbs for Dunkin Donuts.
4. Modify existing concrete Burger King drive-through to be dual lane.
5. Paint bollards as indicated.
6. Install New Burger King Drive through signage:
A. Clearance Bars B. Directional signage C. Canopies and OCUs
7. Seal and restripe existing parking lot for new layout. Remove striping as indicated.
8. Install new Nichiha rain screen at Burger King NE corner.
9. Install new landscaping at Burger King and Dunkin Donuts drive-throughs.
10. Replace existing exterior light fixtures with LED units.
11. Install new weather stripping/seals on existing exterior doors.
12. Install new Burger King signage and light box on northeast pole sign.
13. Install conduit with pullstrings to future Dunkin Donuts drive-through components, OCU, and directional signage as indicated on the drawings.
14. Install new concrete foundation for 6ft multi-tenant sign (by others) in place of existing
Burger King "button" marquee.
15. Modify north end of site for large truck delivery access.
INTERIOR:
1. Replace all lay-in ceiling tiles and grids in dining area, corridor, and Burger King serving area.
2. Store and reinstall existing LED light fixtures in dining room, corridor, serving area, and bathrooms.
3. Remove existing floor tile and base in the dining room and corridor and replace with polished concrete flooring and specified base.
4. Remove existing Burger King finishes in the dining room, bathrooms, and corridor and install new standard Food Court finishes.
5. Remove Burger King finishes at the Burger King counter and adjacent walls and install new Burger King Garden Grill Food Court image elements and finishes.
6. Burger King menu boards to be reinstalled.
7. Re-laminate doors into corridor with new laminate conforming to current Food Court standards.
8. Remove toilet fixtures, fittings, and finishes and replace with Exchange Food Court
Prototype toilet fixtures, fittings, and finishes.
9. Install new ‘Vanilla shell’ for Dunkin Donuts:
A. Build interior demising walls per Dunkin Donuts plan.
B. Install plywood construction barrier in dining room for Dunkin Donuts space with 4’ x 8’ gasketed door.
C. Bare Concrete Floor for Dunkin Donuts space. Polished concrete floor in FOH space.
D. Prep and polish concrete floor in food court seating area.
E. Extend utilities to Dunkin Donuts area as shown.
10. Install new drink station finishes per Exchange Food Court prototypes.
11. Install new tables, chairs, and booths per Exchange Food Court prototype.
12. The GC is to have drawings prepared by a licensed Fire Protection Engineer and submitted to the Installation for approval prior to any modification of the fire suppression and/or fire alarm system(s).
13. Modifications to Electrical and Mechanical as required for new dining layout and
Electrical, Mechanical, and Plumbing and Gas systems to extend service to the new Dunkin Donuts space. This may include a new electrical panel, and service entrance, if needed. Refer to MEP drawings and specifications.
ACC ACCESSIBLE
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
APPROX APPROXIMATE
BLKG BLOCKING
BOB BOTTOM OF BEAM
BOH BACK OF HOUSE
BLDG BUILDING
CAB CABINET
CLG CEILING
CLR CLEAR/CLEARANCE
CMU CONCRETE MASONRY UNIT
CTR CENTER
C.L. CENTER LINE
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CONST CONSTRUCTION
CT CERAMIC TILE
CW COLD WATER
DEG DEGREES
DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
DPW DIRECTORATE OF PUBLIC
WORKS
DWG(S) DRAWING(S)
EA EACH
EC ELECTRICAL CONTRACTOR ELEV
ELEVATION
ELEC ELECTRICAL
EQUIP EQUIPMENT
EQ EQUAL
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
FC FIXTURE CONTRACTOR
FFE FINISH FLOOR ELEV
FOC FACE OF CABINET
FOG FACE OF GLAZING
FOS FACE OF STUD
FRP FIBERGLASS REINFORCED
PANEL
FIO FURNISHED & INSTALLED
BY OWNER
FOIC FURNISHED BY OWNER
INSTALLED BY CONTRACTOR
FLR FLOOR
FS FLOOR SINK
FT FOOT/FEET
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GWB GYPSUM WALL BOARD
HC HOLLOW CORE
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORZ HORIZONTAL
HR HOUR
HVAC HEATING VENTILATING
AIR CONDITIONING
HW HOT WATER
ID INSIDE DIAMETER
IF INSIDE/INTERIOR FACE
INSUL INSULATION
INFO INFORMATION
JC JOB CAPTAIN
LC LICENSEE
LL LANDLORD
MAX MAXIMUM
MECH MECHANICAL
MC MECHANICAL CONTRACTOR
MEP MECHANICAL, ELECTRICAL
AND PLUMBING
MFG MANUFACTURER
MIN MINIMUM
MLDG MOULDING
MTL METAL
NAT NATURAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OA OVER ALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
PC PLUMBING CONTRACTOR
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PM PROJECT MANAGER
PT PAINT
QT QUARRY TILE
R RADIUS
RCP REFLECTED CEILING PLAN
REF REFERENCE
REQ('D) REQUIRE(D)
REV REVISED/REVISION
SB STARBUCKS
SC SOLID CORE
SHT SHEET
SIM SIMILAR
SOL SOLID
SPECS SPECIFICATION(S)
SQ SQUARE
SF SQUARE FEET
SS STAINLESS STEEL
STL STEEL
STOR STORAGE
SUSP SUSPENDED
TEL TELEPHONE
TEMP TEMPORARY
3PL THIRD PARTY LOGISTICS-
(STARBUCKS SUPPLIED)
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
VCT VINYL COMPOSITE TILE
VD VENDOR DIRECT
(STARBUCKS SUPPLIED)
VERT VERTICAL
VIF VERIFY IN FIELD
WH WATER HEATER
WD WOOD
EF/CI EXCHANGE FURNISHED/ CONTRCTOR INSTALLED
EF/EI EXCHANGE FURNISHED/ EXCHANGE INSTALLED
CF/CI CONTRACTOR FURNISHED/ CONTRACTOR
INSTALLED
OCU ORDER CONFIRMATION UNIT
U.N.O. UNLESS NOTED OTHERWISE
NAME Thomas Timbol
ADDRESS 3911 S. WALTON WALKER BLVD.
DALLAS, TX 75236
PHONE (214) 312-6215
eMAIL timbolt@aafes.com
NAME QUORUM ARCHITECTS, INC.
ADDRESS 825 W. VICKERY BLVD., SUITE 100
FORT WORTH, TX 76104
CONTACT DAVID DUMAN, AIA
PHONE (817) 546-6315
FAX (817) 738-9524
NAME CONWAY-DUNCAN ENGINEERS
ADDRESS 3015 S. FORT AVE. STE. D
SPRING FIELD MO 65807
CONTACT KEVIN CONWAY, CHRIS DUNCAN
PHONE (402) 391-7680
eMAIL kconway@conwayduncan.com
A-101 FLOOR PLAN 10/18/24
A-102 REFLECTED CEILING PLAN 10/18/24
A-103 ROOF PLAN 10/18/24
A-201 EXTERIOR ELEVATIONS 10/18/24
A-202 EXTERIOR ELEVATIONS 10/18/24
A-203 INTERIOR ELEVATIONS 10/18/24
A-301 WALL SECTIONS 10/18/24
A-401 ENLARGED TOILET PLAN 10/18/24
A-600 DOOR AND WINDOW SCHEDULE 10/18/24
A-701 FINISH PLAN AND SCHEDULE 10/18/24
A-900 3D MODEL VIEWS 10/18/24
GENERAL
AS101 SITE PLAN 10/18/24
AS102 SITE DETAILS 10/18/24
AS103 SITE DETAILS 10/18/24
AS104 SITE DETAILS 10/18/24
LS-101 LANDSCAPING PLAN 10/18/24
AD101 DEMOLITION FLOOR PLAN 10/18/24
AD102 DEMOLITION REFLECTED CEILING PLAN 10/18/24
AD103 DEMOLITION ROOF PLAN 10/18/24
AD201 DEMO EXTERIOR ELEVATIONS 10/18/24
AD202 DEMO EXTERIOR ELEVATIONS 10/18/24
BURGER KING COUNTER X X EXIST. STRUCTURE REMAINS
INTERIOR GRAPHICS X X SIGNS + GRAPHICS
EXTERIOR GRAPHICS X X
TOILET ACCESSORIES X X
INTERIOR + EXTERIOR FINISHES X X
INCLUDES WINDOW SILL +
CHAIR RAILS
FURNITURE INSTALLATION X X SCI PROVIDED
FURNITURE REMOVAL & DISPOSAL X
DATA WIRING X X PER DOCUMENTS
AWNINGS & CANOPIES X X
NEW EXTERIOR LIGHTING X X PER DOCUMENTS
NEW INTERIOR LIGHTING X X PER DOCUMENTS
PLUMBING FIXTURES X X
PLUMBING, HVAC, ELECTRICAL X X PER DOCUMENTS
NEW BK DRIVE-THRU WINDOWS X X
LANDSCAPE INSTALL & TRIM X X
PARKING LOT SEAL + STRIPING X X
INSTALL NEW MONUMENT SIGN
FOUNDATION
X X
COORDINATE WITH WAGNER
SIGNS
DEMOLISH EXISTING MONUMENT AND
FOUNDATION
X MAINTAIN EXISTING POWER
EXCHANGE MONUMENT SIGN X X
ACCESSIBLE TOILET SIGNAGE X X
BK + EXCHANGE BUILDING SIGNAGE X X
BK DRIVE-THRU TIMER + HEADSET X X
DRIVE-THRU LOOP DETECTOR X X
BK DRIVE-THRU DIGITAL MENU BOARD
& SCREENS
X X
NEW BK DRIVE-THRU SIGNAGE X X
NEW SITE DIRECTIONAL SIGNAGE X X
GC NOT RESPONSIBLE FOR
DUNKIN DONUTS SITE AND
BUILDING SIGNAGE
PROCUREMENT OR
INSTALLATION
GC TO SUPPLY AND INSTALL
SIGNAGE PER DOCUMENTS
AND ALL ITEMS REQUIRED
FOR COMPLETE OPERABILITY.
REMOVE SITE SIGNAGE X PER DOCUMENTS
PAVING X X
SITE CONSTRUCTION X X PER DOCUMENTS
SITE DEMOLITION X X PER DOCUMENTS
EXISTING CONDITIONS & DEMOLITION X X SPEC, DIVISION 2
GENERAL REQUIREMENTS X X SPEC, DIVISION 1
F U
R N
IS
H
E D
IN
S
T A
L L E
D
F U
R N
IS
H
E D
IN
S
T A
L L E
D
F U
R N
IS
H
E D
IN
S
T A
L L E
DBURGER KING
GC EXCHANGE
EXCHANGE
VENDOR
REMARKS
RESPONSIBILITY SCHEDULE 10/09/2024
1. GENERAL CONTRACTOR SHALL FIELD SURVEY THE LOCATION AND VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE AAFES AND ARCHITECT. ALL PROSPECTIVE GENERAL CONTRACTORS HAVE THE OPPORTUNITY TO SCHEDULE A SITE VISIT PRIOR TO BIDDING. CONTACT THE CONTRACTING OFFICER AND AAFES PROJECT MANAGER TO SCHEDULE DATE
AND TIME OF SITE VISIT.
2. GENERAL CONTRACTOR SHALL COMPLETE ALL WORK AS INDICATED ON THESE PLANS, UNLESS OTHERWISE NOTED. CONTACT THE 787TH CIVIL ENGINEERING SQUADRON TO OBTAIN ALL AVAILABLE AS-BUILT DRAWINGS
BEFORE THE BEGINNING OF CONSTRUCTION.
3. GENERAL CONTRACTOR SHALL OBTAIN PERMITS, APPROVALS, INSPECTIONS, CERTIFICATE FOR COMPLIANCE AND
CERTIFICATE OF OCCUPANCY AS REQUIRED, UNLESS OTHERWISE NOTED. SEE NOTE 18
4. GENERAL CONTRACTOR SHALL CHECK IN WITH AND COORDINATE ALL WORK WITH THE BASE CES PROJECT
MANAGER AND POST ENVIRONMENTAL
5. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRICADES AND TEMPORARY POWER, LIGHT AND TELEPHONE IN ACCORDANCE WITH ALL REQUIREMENTS OF BASE / POST. GENERAL CONTRACTOR SHALL REMOVE ALL OF THESE ITEMS AT THE COMPLETION OF WORK. CONTRACTOR SHALL PROVIDE A
TEMPORARY CONSTRUCTION FENCE AROUND ENTIRE PROJECT SITE.
6. GENERAL CONTRACTOR SHALL HAVE ENTIRE PROJECT SITE CLEANED UPON COMPLETION OF WORK BY A PROFESSIONAL CLEANING SERVICE. CONTRACTOR SHALL CLEAN AND SECURE ENTIRE PROJECT SITE ON A DAILY
BASIS.
7. GENERAL CONTRACTOR SHALL MAINTAIN ON SITE AT ALL TIMES, ALL APPROVED & AS BUILT DRAWINGS INCLUDING
REVISIONS AND ADDENDA.
8. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY & OSHA PRECAUTIONS AND BASE SAFETY
REQUIREMENTS DURING CONSTRUCTION.
9. GENERAL CONTRACTOR SHALL COMPLETE ALL WORK IN A NEAT AND PROFESSIONAL MANNER.
10. GENERAL CONTRACTOR SHALL PROVIDE A ONE (1) YEAR WARRANTY ON ALL WORK AND MATERIALS FROM DATE
OF ACCEPTANCE BY AAFES. (ALSO SEE MECHANICAL SPECIFICATIONS FOR ADDITIONAL WARRANTY REQUIREMENTS.) GENERAL CONTRACTOR'S WARRANTY MUST ALSO INCLUDE LABOR WHEN MANUFACTURER'S
WARRANTY IS "PARTS ONLY.
11. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE RECEIPT OF ALL AAFES SUPPLIED MATERIALS AND EQUIPMENT. GENERAL CONTRACTOR SHALL NOTIFY AAFES IF ANY MATERIALS OR EQUIPMENT HAS NOT ARRIVED AT THE JOB SITE IN A TIMELY MANNER. ALL SHIPMENTS SHALL BE INSPECTED UPON ARRIVAL FOR DAMAGES, SHORTAGES AND INCORRECT MATERIALS. ALL PROBLEMS SHALL BE REPORTED TO AAFES' PURCHASING DEPARTMENT IMMEDIATELY. GENERAL CONTRACTOR SHALL NOTIFY THE CARRIER IMMEDIATELY OF ALL DAMAGES AND/OR SHORTAGES AND OBTAIN A RECEIPT FOR SUCH. AT THE COMPLETION OF THE PROJECT, GENERAL CONTRACTOR SHALL NOTIFY OWNER'S PURCHASING DEPARTMENT OF ANY SURPLUS EQUIPMENT FOR PROPER
DISPOSITION.
12. CONTRACTOR PERSONNEL SHALL HAVE VALID, CURRENT I.D.'s. EVERY VEHICLE OF THE CONTRACTOR SHALL
OBTAIN A BASE PASS.
13. GENERAL CONTRACTOR SHALL COORDINATE ALL TRADES NECESSARY TO COMPLETE THE WORK OUTLINED IN
THESE DOCUMENTS.
14. AT THE COMPLETION OF THE PROJECT, GENERAL CONTRACTOR SHALL PROVIDE ON (1) EXTRA CARTON OF EACH
CEILING TILE AND CERAMIC TILE USED.
15. CONTRACTOR TO CONTACT BASE DPV AND CALL BEFORE YOU DIG.
16. DUE TO THE NATURE OF THE WORK, ALL DIMENSIONS SHOWN SHALL BE CONSIDERED APPROXIMATE.
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION. SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION OF ANY ITEM.
FAILURE TO ADHERE TO THIS PROCEDURE SHALL PLACE FULL RESPONSIBILITY FOR ANY ERRORS DIRECTLY UPON
THE CONTRACTOR.
17. ARCHITECT WILL NOT HAVE CONTROL OVER OR CHARGE OF AND WILL NOT RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, SINCE THESE ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. ARCHITECT WILL NOT BE RESPONSIBLE FOR CONTRACTORS FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE ARCHITECT WILL NOT HAVE CONTROL OR CHARGE OF AND WILL NOT BE RESPONSIBLE FOR ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTORS OR THEIR AGENTS OR
EMPLOYEES, OR OF ANY OTHER PERSONS PERFORMING PORTIONS OF THE WORK.
18. THERE ARE UNDERGROUND UTILITIES ON THE SITE NEAR OR IN THE AREA OF NEW CONSTRUCTION. CONTRACTOR TO OBTAIN AN APPROVED DIGGING PERMIT (AF FORM 103) PRIOR TO ANY SITE WORK. GENERAL CONTRACTOR TO
CALL THE CES AND AAFES PM BEFORE STARTING ANY WORK.
19. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE CAUSED TO EXISTING COMMUNICATIONS FACILITIES AND WILL BE RESPONSIBLE FOR REPAIR OF DAMAGED FACILITIES AT NO COST TO THE GOVERNMENT. IF ANY COMMUNICATIONS CABLES SHOULD BE DAMAGED, CALL THE BASE COMMUNICATION SQUADRON, POST DPW, AND
AAFES PM.
20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING THEIR OWN TELEPHONE SERVICE DURING
CONSTRUCTION AT NO COST TO THE GOVERNMENT.
21. NO MODIFICATION OF THE EXISTING FIRE SPRINKLER SYSTEM IS ANTICIPATED. IF ANY MODIFICATION IS REQUIRED TO THE FIRE SPRINKLER SYSTEM, THE MODIFICATION MUST BE DESIGNED BY A PROFESSIONAL FIRE PROTECTION ENGINEER. ANY AND ALL SPRINKLER MODIFICATION DOCUMENTS, INCLUDING DRAWINGS, DESIGN ANALYSIS, ETC.
MUST BE STAMPED AND SIGNED BY THE REGISTERED PROFESSIONAL FIRE PROTECTION ENGINEER AND
SUBMITTED FOR REVIEW AND APPROVAL.
22. ALL DISCIPLINES (ARCHITECTURAL, ELECTRICAL, MECHANICAL, PLUMBING, FIRE SAFETY, ETC) HAVE INFORMATION
THROUGHOUT THE ENTIRE SET OF DOCUMENTS (DRAWINGS AND SPECIFICATIONS).
23. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVISION AND INSTALLATION OF ALL WORK REQUIRED TO INSTALL ALL ITEMS AND WORK REGARDLESS OF LOCATION IN THE DRAWINGS OR SPECIFICATION IN WHICH THE
INFORMATION IS INCLUDED.
24. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVISION AND WORK INDICATED IN THESE DRAWINGS UNLESS SPECIFICALLY NOTED FOR THESE ITEMS AND WORK TO BE PROVIDED OR INSTALLED BY OTHERS.
25. THE GENERAL CONTRACTOR IS ALSO RESPONSIBLE FOR ALL DEMOLITION, CUTTING, PATCHING, OR RESTORATION OF EXISTING MATERIALS REQUIRED TO INSTALL ALL ITEMS AND WORK INDICATED IN THE DOCUMENTS WHETHER
OR NOT DEMOLITION IS INDICATED TO INSTALL THESE ITEMS AND WORK.
26. REFER TO MEP DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL LIGHTING INFORMATION.
27. ALL LIGHTING FIXTURES TO BE SUPPLIED AND INSTALLED BY GC.
28. REFER TO SCI DRAWINGS FOR BURGER KING SERVING COUNTER AND WALL FINISHES AND DINING AREA
FURNITURE LAYOUT.
29. GC TO BE RESPONSIBLE FOR STORAGE AND CLEANING OF EQUIPMENT TO BE REUSED.
30. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL, STORAGE, CLEANING, REINSTALLATION, &
CONNECTION OF ALL EQUIPMENT & FURNITURE REQUIRING REMOVAL TO ACCOMPLISH THE WORK IN THESE
DOCUMENTS.
31. GENERAL CONTRACTOR TO MAINTAIN THE CURRENT WARRANTY ON THE EXISTING ROOF. THE GC IS TO CONTACT THE BASE AND SEE IF THEY HAVE A BASE WARRANTY ROOF CONTRACTOR AND TO USE THAT CONTRACTOR FOR ALL ROOF WORK TO MAINTAIN THE ROOF WARRANTY. COORDINATE THIS WITH BASE ENGINEERING DEPARTMENT.
32. GC SHALL ADDRESS ANY DISCREPANCIES BETWEEN ARCH/MEP DRAWINGS AND SEATING CONCEPTS DRAWINGS
WITH AN RFI.
33. ABATEMENT OF HAZARDOUS MATERIALS IS NOT INCLUDED IN THIS SCOPE OF WORK. IF SUSPECTED HAZARDOUS MATERIALS, TO INCLUDE ASBESTOS AND LEAD BASED PAINT, ARE UNCOVERED OR DISCOVERED DURING THE WORK, THE CONTRACTOR IS TO CEASE WORK AND NOTIFY THE CONTRACTING OFFICER OF THE DISCOVERY.
34. ALL COMMERCIAL VEHICLES MUST UTILIZE THE CHECKPOINT 9 COMMERCIAL GATE, WHICH IS LOCATED ON
SAYLOR'S POND ROAD.
G-001 TITLE SHEET 10/18/24
G-002 ACCESSIBILITY GUIDELINES 10/18/24
G-003 ACCESSIBILITY GUIDELINES 10/18/24
G-004 ACCESSIBILITY GUIDELINES 10/18/24
G-005 LIFE SAFETY AND CODE ANALYSIS 10/18/24
G-006 MANUFACTURERS / SUPPLIERS 10/18/24
M-101 HVAC PLANS 10/18/24
PD101 DEMOLITION PLUMBING PLAN 10/18/24
P-101 PLUMBING PLANS 10/18/24
P-201 PLUMBING SCHEDULES 10/18/24
SED101 SITE ELECTRICAL DEMOLITION PLAN 10/18/24
SE-101 SITE ELECTRICAL PLAN 10/18/24
E-101 ELECTRICAL PLAN 10/18/24
PME-101 SYMBOLS LEGEND 10/18/24
C1.0 SITE PLAN 10/18/24
C2.0 DEMOLITION PLAN 10/18/24
C3.0 GRADING PLAN 10/18/24
C4.0 EROSION CONTROL PLAN 10/18/24
C5.0 DETAILS 10/18/24
CIVIL
ARCHITECTURAL
MEP
ASD101 DEMO SITE PLAN 10/18/24
NAME BAIRD, HAMPTON & BROWN, INC.
ADDRESS 6300 RIDGLEA PL, #700
FORT WORTH, TX 76116
CONTACT BILL BAIRD
PHONE (682) 348-0748
eMAIL bbaird@bhbinc.com
SCI DRAWINGS ATTACHED FOR REFERENCE
• BURGER KING FRONT COUNTER AND WALL
FINISHES
• EXCHANGE DINING AREA FURNISHINGS
DATE
REVISION NO. &
DESCRIPTION BY
David Duman
2024.10.16 08:04:58-05'00'
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
MRF
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL QAI10/11/23
95% SUBMITTAL QAI03/12/24
QAI
100% SUBMITTAL QAI09/11/24
ISSUE FOR SOLICITATION QAI10/18/24
/1 6/
2:
:1
P
M
G-002
ACCESSIBILITY
GUIDELINES
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
DATE
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
MRF
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL QAI10/11/23
95% SUBMITTAL QAI03/12/24
QAI
100% SUBMITTAL QAI09/11/24
ISSUE FOR SOLICITATION QAI10/18/24
/1 6/
2:
:1
P
M
G-003
ACCESSIBILITY
GUIDELINES
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
DATE
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
MRF
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL QAI10/11/23
95% SUBMITTAL QAI03/12/24
QAI
100% SUBMITTAL QAI09/11/24
ISSUE FOR SOLICITATION QAI10/18/24
/1 6/
2:
:1
P
M
G-004
ACCESSIBILITY
GUIDELINES
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
DATE
13'-0"
6'
4' 3 / 4
7'-4 1/4 "
6'
3'-4"
6'-7"
3'
6'-7"
3'
6'-7"
3'
A. The general building code used for design of this project is the IBC (International Building Code) 2021. This code governs architecture, structure, mechanical, plumbing, civil, electrical and accessibility. This code should be used in conjunction with the following codes and standards:
1. 2021 IEBC (International Existing Building Code)
2. UFC 1-200-01
3. 2021 International Fire Code
4. DoD UFC (Unified Services Criteria) as it applies to Exchange projects, including Force Protection issues.
5. NFPA 70 – 2023 for design of electrical systems and support
6. 2021 IMC (International Mechanical Code)
7. 2021 IPC (International Plumbing Code) for design of plumbing systems and support
8. UFC 3-430-05 and NFPA 54 – 2021 for design of natural gas utility lines
9. ADAAG (Americans with Disabilities Act Accessibility Guidelines) for the implementation of design elements for the promotion of accessibility in the use of the project
10. Comply with all applicable Federal, State and local laws and regulations providing for environmental protection and pollution control.
A. ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL,
STATE, AND FEDERAL REGULATORY AGENCIES, AND APPLICABLE
CODES AND STANDARDS IN EFFECT AT TIME OF CONSTRUCTION.
B. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
SAFETY & OSHA PRECAUTIONS AND LOCAL SAFETY
REQUIREMENTS DURING CONSTRUCTION.
C. SHORE AND BRACE ALL EXCAVATION IN ACCORDANCE WITH
CITY, STATE AND O.S.H.A. REQUIREMENTS.
D. GENERAL CONTRACTOR TO PROVIDE TEMPORARY SAFETY
GUARD RAILS AT ALL FLOOR OPENINGS DURING CONSTRUCTION.
E. GENERAL CONTRACTOR BE RESPONSIBLE FOR AND OBTAIN
PERMITS, APPROVALS, INSPECTIONS, CERTIFICATE FOR
COMPLIANCE AND CERTIFICATE OF OCCUPANCY.
F. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL THIRD
PARTY ENERGY INSPECTIONS THAT MEET BUILDING CODES,
ENERGY CODES, AND LOCAL CODE REQUIREMENTS.
G. THE PROJECT IS SUBJECT TO THE AMERICAN DISABILITY ACT,
ANSI 117.2 AND THE TEXAS ARCHITECTURAL BARRIERS ACT, AND
HAS BEEN DESIGNED ACCORDING TO CRITERIA REQUIRED BY THE
TEXAS ACCESSIBILITY STANDARDS EFFECTIVE AS OF THE PLAN
DATE. NO SIGNS, LIGHT OR SIGNAL STANDARDS, UTILITY POLES
OR OTHER OBSTRUCTIONS SHALL BE PLACED AS TO AFFECT ANY
ACCESSIBILITY FEATURES INCLUDING BUT NOT LIMITED TO ANY
BUILDING INTERIOR OR EXTERIOR ELEMENTS, ACCESSIBLE
PEDESTRIAN ROUTES, CURB RAMPS AND CROSSWALKS WITHOUT
PRIOR WRITTEN APPROVAL FROM THE ENGINEER ACCOMPANIED
BY THE CONTRACTORS CONTINGENCY FOR RESTORING THE
AFFECTED ACCESSIBLE ELEMENT.
H. ALL WALKS SHALL BE SLOPED 5% MAXIMUM IN THE DIRECTIONS
OF TRAVEL AND 2% ON CROSS SLOPES.
I. WHEN REQUIRED BY LOCAL CODES, FIRE LANES MUST BE
INSTALLED (ALL WEATHER SURFACE) PRIOR TO CONSTRUCTION
OF BUILDINGS.
J. ALL DOOR HARDWARE IS TO COMPLY WITH LOCAL, STATE AND
FEDERAL ACCESSIBILITY. THIS INCLUDES BUT NOT LIMITED TO
DOOR CLOSERS, LATCH SETS, LOCK SETS, PRIVACY SETS, PANIC
HARDWARE, CONTROLLERS, AUTOMATIC BOLTS AND DOOR
MOUNTED ELECTRIC STRIKES AND ALARMS. IF ANY SPECIFIED
HARDWARE IS DETERMINED TO BE IN NONCOMPLIANCE, NOTIFY
ARCHITECT PRIOR TO BID DATE ADDITIONAL COST WILL NOT BE
AWARDED AFTER BID HAS BEEN RECEIVED.
K. GENERAL CONTRACTOR IS TO INSTALL BOTH RAMPS AND
SIGNAGE FOR ACCESSIBILITY PER CITY, STATE AND ADA
REQUIREMENTS.
L. CONTRACTOR SHALL COORDINATE ALL CLEARANCE
REQUIREMENTS WITH ADA AND TAS AT FIXTURES, CONTROLS,
AND DOORWAYS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES
PRIOR TO CONSTRUCTION.
M. ALL WOOD USED IN BUILDING ASSEMBLIES SHALL BE FIRE
RETARDANT AND MAY BE REQUIRED TO BE DECAY RESISTANT,
REF: PROJECT MANUAL.
N. ALL PENETRATIONS AT GYPSUM BOARD PARTITION WALL, KNEE
WALLS, BULKHEADS AND BACK UP WALLS ARE TO BE
THOROUGHLY SEALED IN A MANNER APPROPRIATE TO WALL TYPE
PENETRATED. IE. WEATHER TIGHT, ACOUSTICAL NON-RATED AND
FIRE RATED. EXPOSED GYPSUM BOARD TO BE SEALED TAPED
AND BEDDED FOR BEST QUALITY APPEARANCE.
O. CONTRACTOR TO OBTAIN AN APPROVED DIGGING PERMIT (AF
FORM 103) PRIOR TO ANY SITE WORK. UNDERGROUND UTILITIES
ON THE SITE NEAR OR IN THE AREA OF NEW CONSTRUCTION.
BUILDING HEIGHT: ALLOWABLE: 75 FEET, 3 STORIES
PROPOSED: 20'
BUILDING AREA: ALLOWABLE: 38,000 SF (TABLE 503)
EXISTING: 6,218 SF
OCCUPANCY: GROUP A-2, B, S
CONSTRUCTION TYPE: TYPE II-B
BUILDING:
ZONING:
ZONING GROUP: JOINT BASE INDUSTRIAL SUPPORT DISTRICT
USE: RESTAURANT
EXITING:
MAX TRAVEL DISTANCE: 250' WITH SPRINKLER (TABLE 1017.2)
MAX COMMON PATH: N/A
OCCUPANTS: ASSEMBLY
DINING = 58 OCC. (1004.6)
SERVING = 822 SQFT/5 NET = 165 OCC. (TABLE 1004.5)
COMMERCIAL KITCHEN = 3,054 SQFT/ 200 GROSS =
16 OCC
BUSINESS = 576 SQFT/ 150 = 4 OCC
STORAGE = 895 SQFT/ 300 = 3 OCC
246 TOTAL OCCUPANTS
EXITS: >49 X <500 OCCUPANTS: 2 EXITS REQ. 3
PROV.
EXIT SIZING: OTHER EGRESS COMPONENTS: (1005.3)
0.2" x 246 OCC. = 49.2" MINIMUM REQUIRED
134" PROVIDED
PARKING:
PARKING REQUIRED: 69 PROVIDED PARKING SPACES +
3 REQUIRED ACCESSIBLE
(1 REQUIRED TO BE VAN ACCESSIBLE PER TAS 208.2)
'-0
" 49'-6"DIAG
O
NAL
51' - 9 3/4"
71'-4"
<= 1/3 DIAGONAL
FEC
FEC
EXISTING
FIRE PULL
EXISTING
FIRE PULL
EXISTING
FIRE PULL
NEW FIRE
PULL
EXISTINGNEW
E X
IS
T
IN
G
N E
W
PHASE 1
PHASE 2
E X
IS
T
IN
G
N E
WLOADING
PHASE 1
PHASE 2
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
MRF
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL QAI10/11/23
95% SUBMITTAL QAI03/12/24
QAI
100% SUBMITTAL QAI09/11/24
ISSUE FOR SOLICITATION QAI10/18/24
As indicated
/1 6/
2:
:1
P
M
G-005
LIFE SAFETY AND CODE
ANALYSIS
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
APPLICABLE CODES
GENERAL NOTES - LIFE SAFETY PROJECT INFORMATION
1. PHASE 1: (KITCHEN AND EXISTING BURGER KING DRIVE-
THROUGH TO REMAIN OPERATIONAL DURING PHASE 1)
A. INTERIOR WORK TO INCLUDE:
A.1. DEMOLITION & CONSTRUCTION OF INTERIOR FINISHES IN
THE DINING AREA, VESTIBULE, DRINK STATION, SERVICE
COUNTER, AND GUEST RESTROOMS. (BURGER KING
KITCHEN & DRIVE-THROUGH TO REMAIN OPERATIONAL.)
A.2. INSTALLATION OF FURNITURE, SIGNAGE, GRAPHICS,
CEILING ITEMS, ETC. TO COMPLETE THE DINING ROOM.
A.3. INSTALLATION OF DEMISING WALLS, ELECTRICAL
CLOSET, AND CONSTRUCTION BARRIER FOR DUNKIN
DONUTS.
B. EXTERIOR WORK TO INCLUDE:
B.1. ALL SITE MODIFICATIONS EXCEPT FOR BURGER KING
DRIVE-THROUGH AND DRIVE-THROUGH SIDE OF
BUILDING. CLEAR LANE TO REMAIN IN AND OUT OF BK
DRIVE THROUGH.
B.2. DUNKIN DONUTS DRIVE-THROUGH.
B.3. ANY ROOF WORK REQUIRED TO COMPLETE THE
EXTERIOR BUILDING MODIFICATIONS.
2. PHASE 2: (KITCHEN AND DINING ROOM TO REMAIN OPEN, DRIVE
THROUGH CLOSED DURATION OF PHASE 2)
A. EXTERIOR WORK TO INCLUDE:
A.1. BURGER KING DRIVE-THROUGH RENOVATIONS AND ANY
REMAINING SITE ITEMS.
A.2 DRIVE-THROUGH SIDE BUILDING MODIFICATIONS
PHASING PLAN
SCALE: 1/16" = 1'-0"G-005
1 LIFE SAFETY PLAN
SCALE: 1" = 30'-0"G-005
3 PHASING SITE PLAN
DATE
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
MRF
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL QAI10/11/23
95% SUBMITTAL QAI03/12/24
QAI
100% SUBMITTAL QAI09/11/24
ISSUE FOR SOLICITATION QAI10/18/24
/1 6/
2:
:1
P
M
G-006
MANUFACTURERS /
SUPPLIERS
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
WALTON SIGNAGE
10101 REUNION PLACE, SUITE 200
SAN ANTONIO, TX 78216
HEATHER PICOU 210-538-3548
hpicou@waltonsignage.com
MOSS RETAIL AND ENVIRONMENTS
(GRAPHICS)
2643 WEST CHICAGO AVE CHICAGO, IL 60622
bk@mossinc.com Scott Metzger 847.238.4245 smetzger@mossinc.com
LSI INDUSTRIES (GRAPHICS)
10000 ALLIANCE ROAD
CINCINNATI, OH. 45242
BOB LUCAS 480‐368‐9399 OR 602‐740‐9894
Bob.Lucas@LSI‐INDUSTRIES.com
PLAY SYSTEMS/SII (SUPERIOR PLAY SYSTEMS)
(PLAYGROUND MANUFACTURER)
1050 COLUMBIA DR.
CARROLLTON, GA 30717 SHAN MCGUIRE
678‐390‐1915 https://superiorplay.com/
SOFT PLAY, LLC
(PLAYGROUND MANUFACTURER, SAFETY SURFACING,
NON‐CONTAINED PLAY EQUIPMENT)
13620 EAST REESE BLVD. SUITE 300
HUNTERSVILLE, NC. 28078 BROCK HODGE
704‐948‐3430 brock.hodge@softplay.com
VGS, INC (GRAPHICS)
1696 MABRY MILL DRIVE, SW NORTH
CANTON, OH 44709
BURGERKING@VGS‐INC.COM (800)201‐0301 x1
FINGERSAFE USA, INC.
(FINGER IN JAMB SAFETY ‐ PLAYGROUNDS) 115
WEST OGLETHORPE AVENUE SAVANNAH, GA 31401
orders@fingersafe.com
MEAGAN KUJAWSKI 912‐234‐6120
Meagan@Fingersafe.com
DAKTRONICS, INC (DIGITAL READERBOARD) 210
DAKTRONICS DRIVE
BROOKINGS, SD 57006
GREG BREYFOGLE 407‐310‐3695
Greg.Breyfogle@daktronics.com
OPTEC DISPLAYS, INC (DIGITAL
READERBOARD) 1700 SOUTH DESOTO PLACE
ONTARIO, CA 91768
Chad Engstrom (626)252‐8333 cengstrom@optec.com
KONTECHUSA
(INTERIOR AND EXTERIOR BUILDING
LIGHTING) 18045 ROLAND STREET
CITY OF INDUSTRY, CA 91748 (866) 236‐8701
Miguel Martinez (626)622‐1325 mmartinez@kontechusa.com
HILL PHOENIX POWER SYSTEMS DIVISION
(FACTORY INTEGRATED SWITCH GEAR) 8166
INDUSTRIAL BLVD
COVINGTON, GA. 30014
dfr‐info@doverfoodretail.com 770‐285‐3264
HOSHIZAKI AMERICA (ICE MACHINES)
618 HIGHWAY 74 SOUTH PEACHTREE CITY,
GA 30269
ANGIE WARREN (770)487‐2331 x11329 adwarren@hoshizaki.com
SCOTSMAN ICE SYSTEMS (ICE MACHINES)
775 CORPORATE WOODS PARKWAY VERNON
HILLS, IL 60061
Evolution Team (800)726‐8762 x15204 team.resolution@scotsman‐ice.com
APA COLOR GRAPHICS
(LIMITED DECOR ITEMS & GRAPHICS) 2929
PACIFIC DRIVE
NORCROSS, GA 800.543.5775
CHUCK BOGEL 404.355.1355
chuck@apacolorgraphics.com
HAMILTON PARKER COMPANY
(HOLLOW METAL FRAMES & DOORS, WOOD
DOORS, HARDWARE (HINGES, LOCKS, ETC)
1865 LEONARD AVENUE
COLUMBUS, OH 43219
JIM CAMPBELL 614‐358‐7806
jimcampbell@hamiltonparker.com
3M COMMERCIAL CORE DIVISION (WINDOW
FILM)
3M CENTER ST. PAUL, MN
JOE CIAMPI: 704‐771‐2449 OR 800‐328‐0033
jjciampi@mmm.com
NRS ‐ NATIONAL READERBOARD SUPPLY
(READERBOARD LETTERS & SUPPLIES) 160
PAHLONE PARKWAY
PONCHA SPRINGS, CO 81242
Patrick Case 800‐243‐6676 Sales@nationalreaderboard.com
FEDERAL HEATH SIGN CO (CANOPIES AND
SIGNS) 12704 DUPONT CIRCLE
TAMPA FL 33626
FIONA PAUL 813‐855‐4415
fpaul@federalheath.com
CREE LIGHTING
(INTERIOR AND EXTERIOR LIGHTING,
SURVEYS AND PHOTOMETRICS)
9201 WASHINGTON AVENUE
RACINE, WI 53406
ELVIR SULJIC 262‐884‐3332
esuljic@creelighting.com
VAOPTO, LLC
(INTERIOR AND EXTERIOR BUILDING
LIGHTING) 5178 WEST PATRICK LANE
LAS VEGAS, NV 89188 Linda Xu (702)517‐5789 linda@vaopto.com
MANITOWOC ICE (ICE MACHINES)
2110 SOUTH 26TH STREET MANITOWOC, WI
54221 JOAN SALAH 813‐504‐9262
Joan.Salah@welbilt.com
KOLPAK, A WELBILT COMPANY (WALK‐IN COOLERS /
FREEZERS) 952 KISSWICH MANOR LANE BALDWIN, MO
63011
JOAN SALAH 813‐504‐9262
Joan.Salah@welbilt.com
WAUSAU TILE, INC
(EXTERIOR DÉCOR FURNITURE & ACCESSORIES)
P.O. BOX 1520 WAUSAU, WI 54402
RACHEL BATHKE 715‐241‐0320
RRBathke@wausautile.com
READY ACCESS
(DRIVE THRU WINDOWS & AIR CURTAINS)
1815 ARTHUR DRIVE WEST
CHICAGO, IL. 60185
KELLY MCGOLDRICK: 800‐621‐5045 EXT 113
kelly@ready‐access.com
COMMERCIAL INTERIORS MANUFACTURING
(RESTROOM PARTITIONS, HOLLOW METAL
FRAMES & DOORS, HARDWARE (HINGES,
LOCKS, ETC)
158 HOLLY STREET
JASPER, GA 30143
AUSTIN HOLAN: 706.299.0327
austin@cimgbiz.com
ENTERA SIGNS (CANOPIES AND SIGNS) 1200
ENTERA DRIVE PANAMA CITY, FL. 32401
MATT CZAJKOWSKI 850‐691‐9652
matt.czajkowski@enterabranding.com
CUMMINGS SIGNS, INC (CANOPIES AND
SIGNS) 105 DALTON PLACE WAY KNOXVILLE,
TN 37912 JOEL EFFLER 615‐872‐5483
joel.effler@cummingssigns.com
LSI INDUSTRIES INC.
(INTERIOR AND EXTERIOR LIGHTING,
SURVEYS AND PHOTOMETRICS)
10000 ALLIANCE ROAD
CINCINNATI, OH. 45242
BOB LUCAS 480‐368‐9399 OR 602‐740‐9894
Bob.Lucas@LSI‐INDUSTRIES.com
ENERGYWISE SOULUTIONS, LLC
(MASTER LIGHTING CONSOLIDATOR,
SURVEYS AND PHOTOMETRICS)
8550 UNITED PLAZA BOULEVARD, SUITE 702
BATON ROUGE, LA 70809
JENNIFER WADDICK 877‐225‐1336
jennifer@energywisemail.com
INTERNATIONAL COLD STORAGE (ICS) (WALK‐IN
COOLERS / FREEZERS, DRY STORAGE
COMPARTMENTS)
215 EAST 13th STREET ANDOVER, KS. 67002
LYNNE CLATTERBUCK 316‐218‐4126
Lynne.clatterbuck@icsco.com
TAYLOR ULTIMATE SERVICES, INC
(SHAKE MACHINE, FROZEN BEVERAGE
MACHINE) 1780 NORTH COMMERCE PKWY
WESTON, FL. 33326
RJ PIEDRA: 954‐217‐9100
raul@taylorus.com
TWENTY FOUR 7 GLOBAL SOLUTIONS, INC. (GARDEN
GRILL, PRIME & ROYAL CHAIRS AND BARSTOOLS)
898 NORTH SEPULVEDA BLVD, SUITE 465 EL
SEGUNDO, CA 90245
GIANNE WON 323‐319‐2727
gianne.won@twentyfour7‐global.com
QUIKSERV
(DRIVE‐THRU WINDOWS & AIR CURTAINS)
11441 BRITTMOORE PARK DRIVE HOUSTON,
TX. 77041
800‐388‐8307
BRIAN MCCLOSKEY
bmccloskey@quikserv.com
MARLITE
(RESTROOM PARTITIONS, ALUMINUM
FRAMES & DOORS, DOOR HARDWARE,
(HINGES, LOCKS, ETC)
202 HARGER STREET
DOVER, NH 44622 800‐377‐1221
ANITA CRAIG 330‐260‐7621 acraig@Marlite.com
ALLEN INDUSTRIES, INC (CANOPIES AND
SIGNS) 11351 49TH STREET NORTH
CLEARWATER, FL 33762 ALAN BRYANT
336‐317‐0195 Alan.Bryant@allenindustries.com
LEKTRON, INC
(LED PARAPET LIGHT BANDS) 4111 S. 74th E. Ave.
TULSA, OK. 74145
ERIC PYLE 918‐622‐4978
BurgerKing@LektronInc.com
SECURITY LIGHTING SYSTEMS
(FULL STORE PACKAGE LIGHTING FOR
INTERIOR/EXTERIOR BUILDING & SITE
LIGHTS, SURVEYS AND PHOTOMETRICS) 2100
GOLF ROAD, SUITE 460
ROLLING MEADOWS, IL. 60008
WHITNEY WATSON: 800‐544‐4848 EXT 131
wilg@securitylighting.com
HERMITAGE LIGHTING NATIONAL
ACCOUNTS (MASTER LIGHTING
CONSOLIDATOR, SURVEYS AND
PHOTOMETRICS)
3640 TROUSDALE DRIVE
NASHVILLE, TN. 37204
WYATT CULVER (615) 843‐3379
wculver@gohermitage.com
DIVISION 8 ‐ DOORS AND WINDOWS DIVISION 10 ‐ SIGNS & CANOPIES DIVISION 16 ‐ ELECTRICAL CORNELIUS, INC. (BEVERAGE SYSTEM)
101 BROADWAY STREET WEST OSSEO, MN 55369
ROSS DAVIS: 630‐659‐8690
ross.davis@cornelius.com
Customer 1st LLC (SAFES)
8899 EAST DAILY ROAD, SUITE #51
PEKIN, IN 47165
MIKE MARCOSA ‐877‐768‐9970
mike@customer1stsafes.com
ECOLAB FOOD SAFETY SPECIALTIES INC,
DBA DAYDOTS (FIRST AID KITS)
201 EAST JOHN CARPENTER FREEWAY
IRVING, TX 75062
ANNA MALHIS 800‐321‐3687
customercare@daydots.com
FRYMASTER CORPORATION (FRYERS)
8700 LINE AVE
SHREVEPORT, LA 71106 JOAN SALAH 813‐504‐9262
Joan.Salah@welbilt.com
LANCER CORP. (BEVERAGE SYSTEM) 6655
LANCER BLVD
SAN ANTONIO, TX. 78219
GREG EDWARDS: 817‐692‐5094
greg.edwards@lancercorp.com
NAUTICAL FURNISHINGS, LLC (LIMITED
DÉCOR ITEMS)
60 NW 60TH STREET
FT. LAUDERDALE, FL 33309 MICHAEL
HOGLUND: 954‐771‐1100
mhoglund@nauticalfurnishings.com
NICHIHA USA LLC (FIBERCEMENT PANELS)
6465 EAST JOHNS CROSSING, SUITE 250
JOHNS CREEK, GA 30097
NICHIHA CUSTOMER SERVICE (770) 805‐9466
BK@NICHIHA.COM
H&K INTERNATIONAL
(STAINLESS STEEL BATHROOM SINKS) 2200
SKYLINE DRIVE
MESQUITE, TX 75149
HEATHER VALVERDE 214‐818‐3521
heather.valverde@hki.com
ZURN INDUSTRIES (PLUMBING FIXTURES)
CONTACT:
HAINES, JONES, AND CADBURY
or RESTROOM REMODELS COMPANY
H&K INTERNATIONAL
(BROILER AND FRYER VENTILATION HOODS) 2200
SKYLINE DRIVE
MESQUITE, TX 75149
HEATHER VALVERDE 214‐818‐3521
heather.valverde@hki.com
GAYLORD INDUSTRIES, INC
(BROILER AND FRYER VENTILATION HOODS) 10900
SOUTHWEST AVERY STREET TUALATIN, OR, 97062
ROB CARMICHAEL 770‐265‐2562
Rob.Carmichael@gaylordventilation.com
TRIMARK USA
(KITCHEN EQUIPMENT CONSOLIDATOR,
SMALLWARES FOR AAFES ORDERS ONLY)
2601 HOPE CHURCH ROAD WINSTON‐SALEM,
NC 27103 BILLY HIGH 336‐354‐4262
billy.high@trimarkusa.com
PITCO FRIALATOR (FRYERS)
10 FERRY STREET
CONCORD, NH. 03301
MARK MCCABE: 603‐230‐5509
MMcCabe@pitco.com
SEATING CONCEPTS (DECOR)
125 CONNELL STREET
ROCKDALE, IL. 60436 (815)730‐7980
ZACH DEPYSSLER
zdepyssler@seating‐concepts.com
FIRESTONE METAL PRODUCTS (METAL ROOF)
250 WEST 96TH STREET INDIANAPOLIS, IN 46260
YUSUKE KOREEDA: 615‐345‐9991
koreedayusuke@firestonebp.com
G.A.F.
(FLAT ROOF) 1361 ALPS ROAD
WAYNE, NJ. 07470
(201) 628‐3000 800‐766‐3411
SAN JAMAR
(KITCHEN PAPER TOWEL DISPENSORS &
SUPPLIES) 555 KOOPMAN LANE
ELKHORN, WI. CONTACT: FRANKE, INC.
H&K INTERNATIONAL QUALSERV
SOLUTIONS
WORLD DRYER, CO (HAND DRYERS)
CONTACT:
HAINES, JONES, & CADBURY (HJC)
RESTROOM REMODELS COMPANY
HAMILTON PARKER
FRANKE, INC.
(BROILER AND FRYER VENTILATION HOODS) 800
AVIATION PARKWAY
SMYRNA, TN 37086 800‐877‐5718
fs‐bkparts.us@franke.com
AMEREX CORPORATION (FIRE PROTECTION
SYSTEMS) 7595 GADSDEN HIGHWAY
TRUSSVILLE, AL 35173‐0081
JAMES KNOWLES 205‐655‐5721
james.knowles@amerex‐fire.com www.amerex‐fire.com
H & K INTERNATIONAL
(KITCHEN EQUIPMENT CONSOLIDATOR,
SMALLWARES, HOODS)
2200 SKYLINE DR
DALLAS, TX 75223
HEATHER VALVERDE 561‐626‐1020
heather.valverde@hki.com
NIECO CORPORATION (BROILERS)
7950 CAMERON DRIVE
WINDSOR, CA 95492 GUIDO NAVA 630‐303‐6824
gnava@nieco.com
FACILITY CONCEPTS, INC (FCI) (DECOR)
7676 ZIONSVILLE ROAD
INDIANAPOLIS, IN 46268 (800)915‐8890
customerservice@fcius.com KEN WEAVER kweaver@fcius.com
BERRIDGE ROOFING (METAL ROOF) TYLER HALL
SAN ANTONIO, TX. 210‐650‐7047
TAMKO ROOFING PRODUCTS (FLAT
ROOFING)
P.O. BOX 1404 JOPLIN, MO. 64802 800‐641‐4691
AMERICAN STANDARD (RESTROOM
ACCESSORIES) 1 CENTENNIAL AVENUE
PISCATAWAY, NJ. 08854 CONTACT:
HAINES, JONES, & CADBURY (HJC)
RESTROOM REMODELS COMPANY
HAMILTON PARKER
HAMILTON PARKER COMPANY
(RESTROOM PLUMBING & ACCESSORIES,
HIGH CHAIRS) 1865 LEONARD AVENUE
COLUMBUS, OH 43219
JIM CAMPBELL 614‐358‐7806
jimcampbell@hamiltonparker.com
TRANE
(AIR CONDITIONING UNITS, RTU's/SPLIT SYSTEMS
CONTROLS)
2884 CORPORATE WAY
MIRAMAR, FL. 33025
CHRIS ST. JOHN 407‐325‐7123
bkhvac@trane.com
LOREN COOK CO (EXHAUST FANS) 2015 E. DALE
SPRINGFIELD, MO 65803‐4637 BRENT FULLERTON
417‐869‐6474 bfullerton@lorencook.com
QUALSERV SOLUTIONS
(KITCHEN EQUIPMENT CONSOLIDATOR,
SMALLWARES) 7400 SOUTH 28th STREET
FORT SMITH, AR. 72908
BRITTANY GOODWIN (479)646‐8386 x335 BGoodwin@qualservsolutions.com
DUKE MANUFACTURING
(BROILERS & PRODUCT HOLDING UNITS) 2305 NORTH
BROADWAY
ST. LOUIS MO. 63102
RICK GARRIGA 306‐606‐2084
rgarriga@dukemfg.com
FCC COMMERCIAL FURNITURE (INTERIOR &
EXTERIOR DÉCOR) 8452 OLD HWY. 99 NORTH
ROSEBURG, OR. 97470 PRESTON O'HARA
800‐322‐7328 EXT 284
preston.ohara@fccfurn.com
DURO‐LAST ROOFING (FLAT ROOFING)
525 MORLEY DRIVE
SAGINAW, MI 48601
nationalaccounts@duro‐last.com 800‐432‐9331
BASF CORPORATION (POLYURETHANE
ROOFING SYSTEMS) 1703 CROSS POINT AVE
HOUSTON, TX 77054
ANDREW FOPPE (980) 218‐1894
andrew.foppe@basf.com
DIVISION 7 ‐ THERMAL MOISTURE PROTECTION HAINES, JONES, AND CADBURY (HJC)
(RESTROOM PLUMBING & ACCESSORIES,
TOLIET
PARTITIONS, CORIAN SINKS, WATER
HEATERS, HIGH CHAIRS)
310 SW 24TH STREET BENTONVILLE, AR 72712
bk@hjcinc.com OR 800‐459‐7099
RESTROOM REMODELS COMPANY
(RESTROOM PLUMBING & ACCESSORIES,
CORIAN SINKS) 15 HAMMATT STREET
IPSWICH, MA 01938
Krislynn Maciel 978‐525‐0008 kris@restroomremodels.com
ECOLAB
(WATER FILTERS)
1801 RIVERBEAND WEST DRIVE FORT WORTH, TX
76118
AL POWELL 816‐206‐2513
al.powell@ecolab.com
CARRIER CORPORATION (AIR CONDITIONING) 6304
CARRIER PARKWAY
SYRACUSE, NY. 13221
KEN REVILLA 954‐218‐0070
Ken.revilla@carrier..com
HM ELECTRONICS, INC (HME) (DRIVE THRU
HEADSETS) 14110 STOWE DRIVE
POWAY, CA. 92064 STEVE LEE 858‐848‐3704
SLee@hme.com
FRANKE
(KITCHEN EQUIPMENT CONSOLIDATOR,
SMALLWARES, HOODS)
800 AVIATION PARKWAY
SMYRNA, TN. 37086
CUSTOMER SERVICE: 800‐877‐5178
fs‐bkparts.us@franke.com JOHN EDMONDS 615‐267‐1563 john.edmonds@franke.com
ELKAY SYSTEMS (FORMERLY ISI) (DECOR)
241 NORTH BROADWAY, SUITE 600
MILWAUKEE, WI 53202
CHRISTINA GUTIERREZ 414.847.0709
christina.gutierrez@elkay.com
ADDISON STEEL (STRUCTURAL STEEL) ADDISON, IL
256‐747‐1554
REDBUILT TRUSSES
(PRE‐FABRICATED ENGINEERED TRUSSES)
Delaware, OH 43015
JARVIS JACKSON 740‐368‐4229
jjackson@redbuilt.com
BOBRICK/KOALA KARE PRODUCTS
(RESTROOM ACCESSORIES, TOILET
PARTITIONS & HARDWARE, BABY CHANGING
TABLES & HIGHCHAIRS) CONTACT:
HAINES, JONES, & CADBURY (HJC)
RESTROOM REMODELS COMPANY
HAMILTON PARKER
SPROVERI'S CUSTOM COUNTERS (CORIAN
VANITY SINKS)
55 LAURA DRIVE
ADDISON, IL 60101 CONTACT:
HAINES, JONES, & CADBURY (HJC)
RESTROOM REMODELS COMPANY
DIVISION 5 ‐ METALS DIVISION 6 ‐ WOODS, COMPOSITES DIVISION 10 ‐ SPECIALTIES 3M FOOD SERVICE (WATER FILTERS) 3M CENTER
BLDG. 223‐2N‐20
ST. PAUL, MN. 55144‐1000 DAVID RADCLIFF
518‐281‐7754 dpradliff@mmm.com foodservice@mmm.com
ANTUNES (WATER FILTERS)
180 KEHOE BOULEVARD CAROL STREAM, IL 60188
SUSAN SUTTER 630‐784‐3447
susan.sutter@antunes.com
LG ELECTRONICS
(INTERIOR & OUTDOOR DIGITAL MENU
BOARD SCREENS) 2000 MILLBROOK DRIVE
LINCOLNSHIRE, IL 60069 MICHAEL HA
847‐941‐8855 michael1.ha@lge.com
3M FOOD SERVICE BUSINESS (DRIVE THRU
HEADSETS)
3M CENTER BLDG. 223‐2N‐20
ST. PAUL, MN. 55144‐1000 JOE CIAMPI:
704‐771‐2449 jjciampi@mmm.com
CHARTER HOUSE INC. (INTERIOR &
EXTERIOR DÉCOR) 4660 136 AVENUE
HOLLAND, MI. 49424 800‐314‐7659
KEITH LEBERT 248‐996‐0315
keith.lebert@charter‐house.com
HC MUDDOX BRICK CO. (FACE BRICK)
4875 BRADSHAW ROAD
SACRAMENTO, CA 95827 ERIN LYNCH
916‐206‐7831
BORAL STONE
(MANUFACTURED STACKED STONE) 1370
GRAND AVENUE, SUITE B
SAN MARCOS, CA 92078 SUSAN KING (413)
207‐7285 Susan.King@boral.com culturedstone@boral.com
ARMSTRONG STRATEGIC ACCOUNTS
(CEILING TILE)
CHERYL SMITH 252‐214‐4426
cbsmith@armstrongceilings.com
OR ARMSTRONG STRATEGIC ACCOUNTS (800)
442‐4212 armstrongcsa@armstrongceilings.com
USG INTERIORS (CEILING TILE)
JOHN FUNES 312.436.5841 JFUNES@USG.COM
NOTE: USE PROGRAM QUOTE # 00103139 TO
RECEIVE NATIONAL BKC PRICING
RHEEM
(WATER HEATERS)
RHEEM NATIONAL ACCOUNT PRICING THROUGH
HAINES, JONES, & CADBURY
bk@hjcinc.com OR 800‐459‐7099
SELECTO SCIENTIFIC, INC (WATER FILTERS)
3980 LAKEFIELD COURT
SUWANEE, GA. 30024
CUSTOMER SERVICE (800)635‐4017 x3
Samsung/LSI
(INTERIOR & OUTDOOR DIGITAL MENU
BOARD SCREENS) 10000 ALLIANCE ROAD
CINCINNATI, OH 45242
DAVID WATFORD 850‐826‐4602
d.watford@sea.samsung.com
PANASONIC
(DRIVE THRU HEADSETS)
2 RIVERVIEW PLAZA, 6TH FLOOR NEWARK, NJ
07102
THERESA MURPHY 201‐492‐0925
theresa.murphy@us.panasonic.com
CASABLANCA DESIGN GROUP (DECOR)
811 PICKENS INDUSTRIAL DRIVE MARIETTA,
GA 30026
JOHN HARRISON 770‐423‐9575
John.Harrison@cdg.com
PINE HALL BRICK CO.
(THIN BRICK & FACE BRICK) 2701 SHOREFAIR
DRIVE, NW WINSTON‐SALEM, NC 27105
THERESA BEANE: (800) 334‐8689
TBEANE@PINEHALLBRICK.COM
EVOLUTION BRICK
(THINK BRICK, PANELIZED THIN BRICK &
FACE BRICK) 126 OLD HIGHWAY 60 EAST
HARDINSBURG, KY 40143 GABE POWERS:
(502) 558‐4612 gabe@evolutionbrick.com FOR FINISH MATERIALS, AND CONTACTS, REFER TO FINISH SCHEDULES
RINNAI
(INSTANT WATER HEATERS)
RINNAI NATIONAL ACCOUNT PRICING THROUGH
HAINES, JONES, & CADBURY
bk@hjcinc.com OR 800‐459‐7099
EVERPURE, INC (WATER FILTERS)
1040 MUIRFIELD DRIVE HANOVER PARK, IL. 60133
SEAN TEAL 630‐306‐0296
sean.teal@pentair.com
SICOM (XENIAL)
(POS, IDMB&ODMB HARDWARE/SOFTWARE,
SPEED OF SERVICE TIMER, KITCHEN MINDER
‐CHEF)
4434 MEADOW DRIVE
DOYLESTOWN, PA, 18901
bksales@sicom.com
MICHAEL SCHWARTZ 215‐489‐2500 EXT 2249
michael.schwartz@xenial.com
STRATACACHE
(CONTROLLERS FOR INTERIOR MENU BOARDS
AND OUTDOOR DIGITAL MENU BOARDS)
40 North Main Street Dayton Ohio 45423
KEVIN FENTON (678)427‐3139
kfenton@stratacache.com
BMC USA LLC
(INTERIOR & EXTERIOR DÉCOR)
2655 SOUTH LE JEUNE ROAD, SUITE 905
CORAL GABLES, FL 33134
EMILIO MARTINEZ FERNÁNDEZ
emiliomartinez@bmcec.com
DIVISION 4 ‐ MASONRY DIVISION 9 ‐ FINISHES DIVISION 15 ‐ MECHANICAL EQUIPMENT, PLAYGROUNDS AND DÉCOR
UPDATE: 5‐20‐2022
This list is intended to assist the contractor in sourcing building materials and products. In many cases, approved Burger King materials and products may be purchased directly from these sources at a national accounts price. For a complete listing of approved manufacturers, see plans and specifications, and visit RSI's eRedbook.
DIRECTORY OF MANUFACTURERS AND SUPPLIERS
DATE
6'-7"
3' 4"
LO
AD
IN
G
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
BB
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL BB10/11/23
95% SUBMITTAL BB03/12/24
BB
100% SUBMITTAL BB09/11/24
ISSUE FOR SOLICITATION BB10/18/24
/1
4/
0:
:5
AM
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
DATE
REVISION NO. &
DESCRIPTION BY
6300 Ridglea Place, Suite 700 | Fort Worth, TX 76116
BAIRD, HAMPTON & BROWN
engineering & surveying project (817)338-1277 | mail@bhbinc.com | TBPE Firm #44 | TBPLS Firm #100113002022.217.015
N
W
S
E
(24"x36") (12"x18")
GRAPHIC SCALE: 1" =
1" =
0 603030 15
Feet Feet
SITE PLAN
C1.0
SITE PLAN
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
BB
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL BB10/11/23
95% SUBMITTAL BB03/12/24
BB
100% SUBMITTAL BB09/11/24
ISSUE FOR SOLICITATION BB10/18/24
/1
4/
0:
:5
AM
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
DATE
REVISION NO. &
DESCRIPTION BY
6300 Ridglea Place, Suite 700 | Fort Worth, TX 76116
BAIRD, HAMPTON & BROWN
engineering & surveying project (817)338-1277 | mail@bhbinc.com | TBPE Firm #44 | TBPLS Firm #100113002022.217.015
N
W
S
E
(24"x36") (12"x18")
GRAPHIC SCALE: 1" =
1" =
0 603030 15
Feet Feet
DEMOLITION
PLAN
C2.0DEMOLITION PLAN
4"
LO
AD
IN
G
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
BB
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL BB10/11/23
95% SUBMITTAL BB03/12/24
BB
100% SUBMITTAL BB09/11/24
ISSUE FOR SOLICITATION BB10/18/24
/1
4/
0:
:5
AM
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
DATE
REVISION NO. &
DESCRIPTION BY
6300 Ridglea Place, Suite 700 | Fort Worth, TX 76116
BAIRD, HAMPTON & BROWN
engineering & surveying project (817)338-1277 | mail@bhbinc.com | TBPE Firm #44 | TBPLS Firm #100113002022.217.015
N
W
S
E
(24"x36") (12"x18")
GRAPHIC SCALE: 1" =
1" =
0 603030 15
Feet Feet
GRADING PLAN
C3.0
4"
LO
AD
IN
G
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
BB
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL BB10/11/23
95% SUBMITTAL BB03/12/24
BB
100% SUBMITTAL BB09/11/24
ISSUE FOR SOLICITATION BB10/18/24
/1
4/
0:
:5
AM
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
DATE
REVISION NO. &
DESCRIPTION BY
6300 Ridglea Place, Suite 700 | Fort Worth, TX 76116
BAIRD, HAMPTON & BROWN
engineering & surveying project (817)338-1277 | mail@bhbinc.com | TBPE Firm #44 | TBPLS Firm #100113002022.217.015
N
W
S
E
(24"x36") (12"x18")
GRAPHIC SCALE: 1" =
1" =
0 603030 15
Feet Feet
EROSION
CONTROL PLAN
C4.0
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
BB
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL BB10/11/23
95% SUBMITTAL BB03/12/24
BB
100% SUBMITTAL BB09/11/24
ISSUE FOR SOLICITATION BB10/18/24
/1
4/
0:
:5
AM
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
DATE
REVISION NO. &
DESCRIPTION BY
6300 Ridglea Place, Suite 700 | Fort Worth, TX 76116
BAIRD, HAMPTON & BROWN
engineering & surveying project (817)338-1277 | mail@bhbinc.com | TBPE Firm #44 | TBPLS Firm #100113002022.217.015
DETAILS
C5.0
= APPROXIMATE AREA OF EXCAVATION -
COORDINATE WITH PROPOSED CONSTRUCTION
EXISTING BUILDING
131313
TEXAS AVE.
B R
O
ID
Y R
D
17 7
A. COORDINATE EXTENT OF REQUIRED DEMOLITION WITH NEW CONSTRUCTION.
B. FIELD VERIFY ALL DIMENSIONS AND CLEARANCES PRIOR TO START OF DEMOLITION.
C. ALL CONSTRUCTION TO REMAIN IS TO BE PROTECTED DURING DEMOLITION AND
CONSTRUCTION. ANY DAMAGE IS TO BE REPAIRED TO "LIKE NEW" CONDITION AT NO
EXPENSE TO THE OWNER.
D. SITE TO BE CLEANED OF MATERIALS AND DEBRIS AT END OF WORKDAY.
SCALE:
AAFES Project Number:
DATE:
SHEET:
PROJECT NUMBER
DRAWING TITLE:
Design. Spaces. People.
825 W. Vickery Blvd. #100 Fort Worth, Texas 76104
ph. (817) 738-8095
fx. (817) 738-9524 www.qarch.com
DRAWN BY:
CHECKED BY:
PROJECT:
EXCHANGE
EXCHANGE
CONSTRUCTION TYPE:
STORE TYPE:
CONVERT:
1760-22-000003
15% SUBMITTAL TM07/10/23
MRF
RENOVATION
RESTAURANT
SUBMITTALS BYDATE
35% SUBMITTAL QAI10/11/23
95% SUBMITTAL QAI03/12/24
QAI
100% SUBMITTAL QAI09/11/24
ISSUE FOR SOLICITATION QAI10/18/24
As indicated
/1 6/
2:
:0
P
M
ASD101
DEMO SITE PLAN
18 OCTOBER, 2024
23017
ISSUE FOR
SOLICITATION
ARMY AIR FORCE EXCHANGE SERVICE
BURGER KING TO DUAL
FOOD FACILITY
5399 BROIDY RD, JB-MDL,
NJ 08640
BLDG #5399
SCALE: 3/64" = 1'-0"ASD101
1 DEMO SITE PLAN
15 EXISTING BK DRIVE-THRU CANOPY TO BE REMOVED.
16 EXISTING DRIVE-THRU MENU BOARD TO BE RELOCATED.
17 EXISTING BOLLARDS TO REMAIN.
18 EXISTING DIGITAL PREVIEW BOARD TO BE REMOVED. REMOVE
FOUNDATION AND POWER / DATA BACK TO PANEL.
19 AREA OF PAVING, CURBS, LANDSCAPE TO BE REMOVED.
COORDINATE WITH REQUIREMENTS OF NEW CONSTRUCTION.
20 EXISTING BK POLE SIGN FACES AND CABINET TO BE REPLACED.
MAINTAIN EXISTING CONDUIT AND POWER. PREPARE NEW
CABINET AND EXISTING POLE FOR PAINT FINISH PAINT TO
MATCH DIRECTIONAL SIGNAGE..
21 EXISTING PARKING LOT TO BE SWEPT CLEAN PRIOR TO
RESEALING.
22 EXISTING PARKING LOT STRIPING TO BE REPAINTED.
23 PARKING LOT SPACES TO BE REMOVED. DO NOT PAINT NEW
STRIPING.
24 EXISTING CONCRETE WHEELSTOPS TO BE REMOVED.
25 EXISTING TREES TO REMAIN. PROTECT FROM CONSTRUCTION
DAMAGE.
1 EXISTING MONUMENT SIGN AND FOUNDATION TO BE REMOVED.
RETAIN EXISTING CONDUITS AND POWER FOR REUSE WITH
NEW SIGNAGE.
2 EXISTING LIGHT POLE TO BE RELOCATED. REFER TO SITE PLAN.
3 EXISTING TREE TO BE REMOVED.
4 EXISTING LANDSCAPE AND IRRIGATION TO BE REMOVED.
5 EXISTING LANDSCAPE TO REMAIN. IRRIGATION LINES AND
HEADS WITHIN AREAS OF CONSTRUCTION TO BE REMOVED.
6 EXISTING CONCRETE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .