GFI 04 NNSY Bldg 705 Front Elevation View.pptx

PPTX presentation 199 KB Posted

Attached to
Sole Source UNICOR Contract - NNSY - Workstations & Chairs Federal contract opportunity
Solicitation number
N4215824QN052
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This document is a solicitation from the Department of the Navy Naval Sea Systems Command for the purchase and installation of furniture for the US Navy Shipyard National Preservation Historic Site's 1830-Built Administrative Facility. The requirement includes: seven configurable quad workstation system furniture units providing a total of twenty-eight new workstations, thirty conference room chairs, and thirty workstation chairs. This is a direct award to UNICOR per FAR Part 8.002. Vendors must submit a signed acknowledgement of the SF 1449 Solicitation and a quotation via email by Thursday, August 22, 2024 at 2:00 PM.

View the file

Other files for this federal contract opportunity

Other files attached to Sole Source UNICOR Contract - NNSY - Workstations & Chairs, newest first.
File Type Posted
Solicitation Amendment.pdf PDF
GFI 06 NNSY B705 First Floor AutoCAD.pptx PPTX presentation
GFI 05 NNSY B705 Ground Level AutoCAD.pptx PPTX presentation
GFI 03 NNSY Bldg 705 Site Plan View.pptx PPTX presentation
UNICOR Evaluation Factor.xlsx XLSX spreadsheet
SF-1449 Solicitation N4215824QN052.pdf PDF
GFI 07 NNSY B705 Second Floor AutoCAD.pptx PPTX presentation
Configurable Quad Workstations - Rendering.pptx PPTX presentation

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Navy Norfolk Naval Shipyard Historic District Building 705

Turn-Key Requirement Outfit and Furnish

Building 705 Front Elevation South View

Note 2: Ground Level to First Floor Elevation is 6 Feet 8 Inch Height

Note 1: Ground Level to Second Floor Elevation is 20 Feet 2 Inch Height 1st Floor Elev 2nd Floor Elev Note 3: Basement Level Above Ground Level 6’-8” and Below Ground Level 2’ Basement Floor Elev Note 4: Second Floor Interior Ceiling Height is 10 feet Note 5: First Floor Interior Ceiling Height is 11 Feet

ADA

Elevator Fire Escape Fire Escape Note 6: Front Door Porch includes an exterior ADA Elevator Note 7: East Side and West Side each includes an exterior NFPA Fire Escape NNSY B705 Front Elevation View Doc # NNSY-705-100TO-004 image1.png

File details come from the government source that posted it. Updated .