Generator Maintenance and Repair Services RFP Summary

This is a Request for Proposal (RFP 27-021) issued by the City of Clermont, Florida, for comprehensive maintenance and repair services for all city-owned and operated generators. The solicitation was released November 5, 2026, with a deadline for questions on December 2, 2026, and proposal responses due December 10, 2026, at 2:00 p.m. A non-mandatory pre-proposal conference is scheduled for November 16, 2026, at 10:00 a.m. at City Hall. The RFP covers approximately 140 generators ranging from 20 to 1,280 kilowatts across multiple city facilities, including lift stations, water well sites, fire and police stations, and municipal buildings. Required services include preventive maintenance, inspections, testing, emergency response, and as-needed repairs coordinated with the City's Public Services Department. The initial contract term is thirty-six (36) months, with three optional twelve-month renewal periods available at the City's discretion. Technicians must demonstrate at least five years of relevant commercial generator experience with appropriate manufacturer certifications and qualifications.

Pricing will be evaluated on a competitive basis using the City's Price Proposal Form, with the lowest responsive cost proposal receiving maximum points. The contractor must provide all labor, materials, equipment, tools, and transportation necessary to maintain generators in reliable operating condition in accordance with manufacturer recommendations. Required insurance includes Commercial General Liability ($1,000,000 per occurrence/$2,000,000 aggregate), Automobile Liability ($1,000,000 combined single limit), and Workers' Compensation ($1,000,000 per accident). Evaluation will be based on a 105-point scale including company background and experience (25 points), personnel qualifications (15 points), maintenance methodology (20 points), emergency response capability (15 points), past performance references (10 points), cost proposal (15 points), and business location preference for City of Clermont-based firms (5 points). The City reserves the right to make multiple awards, reject all proposals, re-advertise the solicitation, and negotiate with subsequent ranked respondents if negotiations with the highest-ranked respondent are unsuccessful.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR PROPOSAL

RFP 27-021

GENERATOR MAINTENANCE AND REPAIR SERVICES

City of Clermont

685 W. Montrose Street

Clermont, FL 34711

RELEASE DATE: November 5, 2026

DEADLINE FOR QUESTIONS: December 2, 2026

RESPONSE DEADLINE: December 10, 2026, 2:00 pm

RESPONSES MUST BE SUBMITTED ELECTRONICALLY TO:

https://procurement.opengov.com/portal/clermontfl

City of Clermont

REQUEST FOR PROPOSAL

Generator Maintenance and Repair Services

I. Introduction II. Proposal Procedures

III. Statement of Work IV. Response Format V. Evaluation Process

VI. Terms and Conditions

Attachments:

A - OpenGov Vendor Registration

B - Price Proposal Form

Request For Proposal #RFP 27-021 Title: Generator Maintenance and Repair Services

1. Introduction

1.1. Summary

The City of Clermont is seeking proposals from qualified respondents for the maintenance and repair of all City-owned and operated generators. These generators provide backup power for City lift stations, water well sites, Fire and Police stations, and other City buildings and facilities.

Services include preventive maintenance, inspections, testing, emergency response, as-needed repairs, reporting, and coordination with City staff. Award will be made to the responsive and responsible respondent whose proposal provides the best overall value to the City.

1.2. Contact Information

Ramsey Jimenez Procurement Manager 685 W Montrose St Clermont, FL 34711 Email: rjimenez@clermontfl.org Phone: (352) 241-7353

Department:

Public Services - Environmental Svcs.

1.3. Timeline

The following dates are set forth for information and planning purposes; however, the City reserves the right to change the dates as needed. Respondents are advised to closely monitor any potential date changes through the Portal at https://procurement.opengov.com/portal/clermontfl. (Please note that there is no charge or fee for respondents to register and utilize the Portal).

Solicitation Issued Date November 5, 2026

Newspaper Advertisement November 9, 2026

Pre-Proposal Conference (Non-

Mandatory)

November 16, 2026, 10:00am

City Hall Council Chambers (1st Floor) 685 West Montrose Street, Clermont, Florida The meeting will begin promptly at the time specified above.

Questions Deadline December 2, 2026, 12:00pm mailto:rjimenez@clermontfl.org tel:(352)241-7353

Response Deadline December 10, 2026, 2:00pm

Receipt and Acknowledgment of Responses

The proposal opening will be conducted virtually via Microsoft Teams. Interested parties may participate using the following information:

Join by Microsoft Teams:

https://teams.microsoft.com/meet/2403736044

747151?p=jVNMF8JcqMavO27Diw

Meeting ID: 240 373 604 474 715 1 Passcode: bf3Nr7iY

Join by Phone:

Dial-in Number: +1 (929) 235-8441 Phone Conference ID: 961 643 347#

Participants may join using the Microsoft

Teams link or by calling the dial-in number and entering the conference ID when prompted.

Evaluation / Scoring Meeting (Non-

Mandatory)

TBD

Zoom Meeting Information https://teams.microsoft.com/meet/2403736044747151?p=jVNMF8JcqMavO27Diw https://teams.microsoft.com/meet/2403736044747151?p=jVNMF8JcqMavO27Diw

2. Proposal Procedures

2.1. Definitions

For purposes of this Request for Proposal, the following terms apply:

• City – The City of Clermont, Florida.

• Contract – The agreement resulting from this RFP, including the solicitation, addenda, accepted Proposal, and other documents incorporated into the agreement.

• Contractor – The Respondent awarded a Contract by the City.

• Portal – The City’s OpenGov electronic procurement system used for solicitation communications and Proposal submission.

• Proposal – The complete submission provided by a Respondent in response to this

RFP.

• Respondent – A person, firm, corporation, partnership, joint venture, or other entity submitting a Proposal in response to this RFP.

• RFP – This Request for Proposal, including all addenda issued by the City.

• Successful Respondent – The Respondent selected by the City for contract negotiations or award, as applicable.

2.2. Delivery of Proposal

Proposals must be submitted electronically through the City’s OpenGov Portal by the date and time specified in this solicitation. Proposals will remain sealed and unavailable for review until after the Proposal Deadline. Respondents may modify or withdraw their Proposals through the

Portal at any time before the Proposal Deadline. All Proposals must remain valid for at least ninety (90) calendar days after the Proposal Deadline and will become the property of the City.

Proposals will not be accepted by email, fax, or any method other than the Portal.

All Proposals will be publicly opened electronically through the Portal at the date and time identified in the Timeline section of the #Introduction section. Only the names of the

Respondents who submitted Proposals will be announced.

A. Electronic Proposal Submission

1. Respondents are solely responsible for ensuring that their Proposal is fully submitted and received through the Portal before the Proposal Deadline. The City of Clermont is not responsible for delays in transmission, internet connectivity, system access, or other circumstances that may prevent timely submission. Respondents should allow sufficient time to complete and submit their Proposal.

B. Uploading Electronic Documents https://procurement.opengov.com/portal/clermontfl/projects/318962/document?section=undefined

1. After selecting the “Draft Response” button in the Portal, the Respondent may enter the required information and upload supporting documents. Once all required information has been completed, the Respondent must submit the Proposal through the Portal.

Upon successful submission, the Portal will display a date and time stamp and send a confirmation email to the user’s registered email address. Respondents may review, modify, or withdraw their Proposal at any time before the Proposal Deadline. Proposals will remain sealed and unavailable for review until after the Proposal Deadline.

2.3. Pre-Proposal Conference

Monday, November 16, 2026 at 10:00 am

All potential respondents are encouraged to attend this non-mandatory pre-proposal conference. The meeting will provide an opportunity to ask questions and seek clarification regarding the solicitation requirements.

Verbal discussions during the meeting will not modify or become part of the solicitation unless confirmed in writing through an addendum issued by the City. Questions that cannot be fully addressed during the meeting may be deferred and answered through a subsequent addendum.

All formal responses to material questions will be issued in writing and made available to all potential Respondents through the Portal.

Potential Respondents are encouraged to bring a copy of the solicitation to the pre-proposal conference, as additional copies may not be available.

Meeting Location: City Hall Council Chambers (1st Floor) 685 West Montrose Street, Clermont, Florida The meeting will begin promptly at the time specified above.

2.4. Questions Deadline

To ensure that all prospective respondents have accurately and completely understood the requirements of this solicitation, the City of Clermont Procurement Services Department will accept written questions up until 12:00 pm on Wednesday, December 2, 2026. Verbal inquiries will not be accepted, and potential respondents are instructed only to seek additional information or clarification or to communicate in writing with the Procurement Services Director.

The City of Clermont requires all questions relating to this solicitation to be entered through the

“Question and Answer” tab on the Portal. Responses to questions will be provided online at https://procurement.opengov.com/portal/clermontfl.

• ALL QUESTIONS MUST BE SUBMITTED BEFORE THE DEADLINE.

• QUESTIONS WILL NOT BE ANSWERED VIA TELEPHONE OR FAX.

2.5. Award

The City reserves the right to make multiple awards if deemed appropriate, considering anticipated workload or other factors.

2.6. Contract Negotiations

The City intends to enter into a contract for the services outlined. The responses constitute an agreement that any contract resulting from this solicitation will be prepared by the City.

Consequently, the City does not agree to necessarily accept terms the respondent may propose during the negotiation phase of the contract.

2.7. Contract Period

This contract will commence on the first calendar day of the month, after approval of the contract by the City Council or designee, unless otherwise stipulated in the Notice of Award distributed by the City's Procurement Services Department. The Notice of Award will be contingent upon completing and submitting all required pre-award documents. The initial contract term will remain in effect for thirty-six (36) months, and then the contract will remain in effect until the completion of the expressed and/or implied warranty period. The contract prices resulting from this solicitation will prevail for the full duration of the initial contract term unless otherwise indicated elsewhere in this document.

If stated, estimated quantities are for respondent guidance only, and no guarantee is given or implied as to quantities that will be used during the contract period. Estimated quantities are based on previous needs. The City may use estimated quantities to evaluate the low response and ensure it meets the specifications.

2.8. Option to Renew

Before, or upon completion, of the initial term of this contract, the City will have the option to renew this contract for three (3) additional twelve (12) month period(s). Before the completion of each exercised contract term, the City may consider a price adjustment based on changes in the U.S. Bureau of Labor Statistics, Producer Price Index (PPI) for the most recent twelve (12) month period (see http://www.bls.gov/ppi/ppi_dr.htm Current Edition). It is the contractor's responsibility to request any price adjustment under this provision in writing. The contractor's written request for adjustment should be submitted to the Procurement Services Department sixty (60) days before the anniversary date of the contract. The contractor adjustment request must substantiate the requested increase. The written request for adjustment should not exceed the relevant price index change. If no adjustment request is received from the contractor, the

City will assume that the contractor has agreed that the optional term may be exercised without price adjustment. Any adjustment request received after the commencement of a new option period will not be considered.

The City reserves the right to reject any written price adjustments submitted by the contractor and/or not to exercise any otherwise available option period based on such price adjustments.

Continuing the contract beyond the initial period and any option subsequently exercised is a City prerogative and not a contractor's right. This prerogative will be exercised only when such continuation is clearly in the best interest of the City.

2.9. Insurance Requirements

The respondent(s) must provide proof of insurance when responding to this solicitation using a standard ACORD form, showing no less than the amounts indicated below. If an ACORD form cannot be provided, a signed letter from the insurance company agency, on its letterhead, must be provided stating current insurance as described below, or stating that the agency can receive http://www.bls.gov/ppi/ppi_dr.htm the required insurance coverage.

All suppliers performing work on City property or public right-of-way must provide the City with a certificate of insurance evidencing the coverage and coverage provisions identified herein.

Respondents must provide the City with evidence that all subcontractors performing work on the project have the same types and amounts of coverage as required herein or that the subcontractors are included under the contractor’s policy. The City, at its own discretion, may require a certified copy of the policy.

The types and amounts of insurance required are listed below. The City reserves the right to amend or require additional types and amounts of coverage or provisions depending on the nature of the work.

Minimum Insurance Coverage Requirements with Aggregate Limits

• Commercial General Liability o Per Occurrence: $1,000,000 o General Aggregate: $2,000,000 o Products & Completed Operations Aggregate: $2,000,000

Coverage must include:

▪ Premises/Operations

▪ Products and Completed Operations

▪ Contractual Liability

▪ Contractual Indemnity (in accordance with Section 6.35 of the Terms and

Conditions)

• Automobile Liability o Per Occurrence (Combined Single Limit): $1,000,000 o Aggregate: N/A

Must include owned, non-owned, and hired vehicles.

• Workers’ Compensation and Employer’s Liability

As required by Florida Statutes, Chapter 440, including:

o Each Accident: $1,000,000 o Disease – Each Employee: $1,000,000 o Disease – Policy Limit: $1,000,000 o

Additional Insurance Requirements

• Insurance carriers must be rated at least B+:VI or better by A.M. Best (latest edition) or otherwise approved by the City.

• A minimum of thirty (30) days’ written notice of policy cancellation, non-renewal, or material change is required.

• The City of Clermont must be named as an Additional Insured for General Liability coverage, and this must be explicitly stated on the certificate.

• The certificate must reference the solicitation number and title.

• Certificates of insurance must be submitted to:City of Clermont

685 W. Montrose Street

Clermont, FL 34711

2.10. Reservation of Rights to the City

The issuance of this solicitation and the acceptance of responses do not constitute an agreement by the City that it will enter into a contract with any of the respondents to this solicitation.

The City reserves the right to extend the response deadline, request additional information from any respondents, reject all responses, negotiate with the next qualified respondent if negotiations with the top respondent do not result in an agreement, cancel the project, and/or re-advertise the solicitation. The City reserves the right to disqualify any respondent at the sole discretion of the City.

By submitting a response and subsequent information, the respondents waive the right to object to the exercise of the City’s right to disqualify a respondent and/or a response, either now or in the future.

2.11. Restriction of Communication

Respondents to this solicitation or persons acting on their behalf may not contact, between the issued date of this solicitation and within three (3) business days following the agency posting the notice of intended award, excluding State and Federal holidays, any employee or council members concerning any aspect of this solicitation, except in writing to the Procurement

Services Director. Violation of this provision may be grounds for rejecting a response. In addition, respondents are strongly cautioned that inappropriate efforts to lobby or influence individuals or organizations involved in this selection process may result in dismissal from further consideration. The appeals procedures are located in the Terms and Conditions Section of this solicitation.

2.12. Response expenses

All costs associated with preparing this response will be the sole responsibility of the respondent, including but not limited to document preparation and any and all travel expenses.

2.13. Response Information as Public Documents

All materials initially submitted or subsequently submitted as part of this solicitation process will become the property of the City and will be treated as City documents subject to typical practice and/or applicable laws for public records. Otherwise, the City will not distinguish or treat any material received as confidential, proprietary, and/or a trade secret unless specifically designated as such by the respondent. Financial statements will not become subject to public record as per Section 119.07(1) Florida Statutes. Furthermore, by submitting a response, the respondent agrees to hold the City harmless for any public use or dissemination of all information submitted through this process.

2.14. Permits and Regulations

The respondent shall obtain, at its expense, all licenses, permits, and inspections required for this project, and shall comply with all applicable laws, ordinances, regulations, and building code requirements. The successful respondent may apply for permits online. For permit types and fees, visit the City website www.clermontfl.gov, select Building Services, and download the most recent Building Services Fees Schedule.

2.15. Tie Responses

In the event that two or more respondents receive identical final evaluation scores, and the tie remains after completion of all evaluation criteria, the tie may be broken using the following criteria, in the order listed, as determined by the Procurement Services Director.

A. Quality of the items or services provided, if such quality is ascertainable.

B. Delivery time, if provided in the response by the respondents.

C. Preference of businesses with drug-free workplace programs as defined in Section

287.087, Florida Statutes.

D. The company is closest to the City of Clermont City Hall, whose address is 685

Montrose Street, as determined by the Procurement Services Director.

E. If sections A through D are not applicable, the tiebreaker will be decided by flipping a coin to receive the first opportunity to negotiate, as applicable.

2.16. Lobbying

Lobbying of Evaluation Committee members, City of Clermont employees, or elected officials regarding this Request for Proposal (RFP) by the respondent or any member of the respondent's staff, an agent of the respondent, or any person employed by any legal entity affiliated with an organization that is responding to the RFP is strictly prohibited upon advertisement. Lobbying will be prohibited until a written recommendation of award is made. For purposes of this provision, lobbying activities include, but not be limited to, influencing or attempting to influence action or non-action in connection with this RFP through direct or indirect oral or written communication or an attempt to obtain the goodwill of persons and/or entities specified in this provision. Such actions may cause the RFP response or subsequent contract to be rejected or terminated.

http://www.clermontfl.gov/

3. Statement of Work

3.1. Project Overview

The City of Clermont is seeking qualified and experienced firms to provide preventive maintenance, inspections, testing, emergency response, and as-needed repair services for City-owned and operated generators. These generators provide backup electrical power for critical

City operations, including lift stations, water well sites, public safety facilities, and other City buildings.

The contractor must provide all labor, supervision, materials, parts, tools, equipment, transportation, and services necessary to maintain the generators in reliable operating condition in accordance with manufacturer recommendations and the requirements of this solicitation.

The contractor must coordinate all scheduled services with the City's Public Services

Department and provide a maintenance schedule for City approval before beginning work.

Services must include detailed inspection reports, test results, recommended corrective actions, and documentation of all work performed.

The generators vary in manufacturer, model, capacity, and location. Respondents must demonstrate the qualifications, technical resources, and manufacturer service capabilities necessary to perform the required services on the equipment identified in Section 3.4.

3.2. General Service Requirements

The Contractor must provide preventive maintenance, inspection, testing, and repair services for the generators identified in Section 3.4.

The Contractor must:

A. Coordinate all scheduled maintenance activities with the City's designated representative and obtain approval of the proposed service schedule before beginning work.

B. Submit an annual maintenance schedule identifying each generator, service location, required maintenance activities, and anticipated service dates. The schedule must account for all required annual maintenance, secondary inspections, and scheduled testing and replacement services.

C. Maintain an updated schedule identifying completed services, upcoming maintenance, and outstanding work. The Contractor must provide the updated schedule to the City with each invoice.

D. Complete all scheduled services within the applicable maintenance period unless otherwise approved by the City in writing. Any anticipated delays or changes to the approved schedule must be communicated to the City in advance and include revised completion dates for outstanding services.

E. Coordinate required generator shutdowns or service interruptions with City personnel to minimize disruptions to City operations.

F. Notify the City of equipment deficiencies, conditions affecting generator reliability, or other issues requiring corrective action.

G. Provide field service reports, inspection checklists, testing results, and recommended corrective actions for all services performed.

H. Participate in quarterly meetings with the City to review maintenance progress, completed services, outstanding repairs, and upcoming maintenance activities.

I. Remove all debris, used materials, fluids, filters, and replaced parts and leave each service location in a clean and orderly condition.

J. Perform all services in accordance with applicable manufacturer recommendations, safety requirements, and federal, state, and local regulations.

The City reserves the right to add, remove, replace, or relocate generators during the Contract term. Services for additional or replacement generators will be performed at the applicable

Contract rates.

3.3. Maintenance Services

Each generator included in this solicitation must receive one (1) Full Maintenance Service every twelve (12) months and one (1) additional Preventive Maintenance Inspection (PMI) approximately six (6) months after the Full Maintenance Service.

Coolant flushing must be performed every thirty-six (36) months, beginning in the first year.

Belts must be replaced every thirty-six (36) months, beginning in the second year. Load bank analysis must be performed every thirty-six (36) months, beginning in the third year.

Maintenance services must include, at a minimum, the following:

A. Replace engine lubricating oil during the annual Full Maintenance Service.

B. Replace oil, fuel, and coolant filters and add corrosion inhibitors as needed.

C. Test coolant condition during each annual Full Maintenance Service. Coolant flushing must be performed every thirty-six (36) months, beginning in the first year, or sooner if testing or inspection indicates degradation. The cooling system must be inspected during flushing for corrosion, deposits, leaks, and other deficiencies.

D. For natural gas and LPG-fueled engines, inspect spark plugs, spark plug wires, rotors, and caps, as applicable, and replace as needed.

E. Inspect air filters and crankcase breathers and replace as needed. Provide at least two

(2) photographs documenting the condition of components recommended for replacement.

F. Inspect belts during each PMI and replace them at least every thirty-six (36) months, beginning in the second year, regardless of apparent wear. Photographs must be provided during inspections and replacement.

G. Inspect the generator for loose, bare, or broken wiring and connections. Document deficiencies and obtain City authorization before performing repairs outside the scheduled maintenance services.

H. Inspect the fuel system, including fuel lines, hoses, connections, separators, and fuel pressure. Drain accumulated water from fuel separators as needed.

I. Inspect the air intake and exhaust systems, including the exhaust manifold, valves, valve rotators, and exhaust duct, as applicable.

J. Inspect the starting system, including batteries, battery connections, battery chargers, and starting motors.

K. Check applicable DC voltage and current readings.

L. Inspect fuses, electronic connections, and capacitors to ensure compliance with manufacturer specifications.

M. Inspect and verify the operation of the automatic transfer switch during scheduled maintenance.

N. Conduct load bank analysis for three (3) to four (4) hours in accordance with the thirty-six (36) month testing schedule, beginning in the third year, and provide a written report documenting generator performance and test results.

O. Perform fuel testing during each annual Full Maintenance Service for all generators, using the applicable testing method based on the generator's fuel system. Testing must include appearance and haze, water content, microbial contamination, and sediment, where applicable to the fuel type.

P. Perform oil analysis during each annual Full Maintenance Service for all generators and provide the test results to the City with the service report and invoice.

Q. Submit written service reports identifying completed maintenance activities, generator condition, deficiencies, and recommended corrective actions.

All leaks must be documented in the service report. The Contractor must clean up any fluids spilled during service and properly dispose of waste materials. Any unresolved leaks or conditions affecting generator operation must be reported to the City before leaving the service location.

Fuel and oil analysis results must be submitted to the City's Environmental Services Division with the applicable invoice. Invoices must include all required supporting documentation in accordance with Section 3.7, Invoicing and Payment Requirements.

3.4. Preventive Maintenance Service Locations

The generators covered under this solicitation are identified in the table below. The inventory includes available equipment information, generator capacities, manufacturers, models, and service locations.

The Contractor must provide maintenance and repair services at the identified locations and coordinate access with the City's designated representative.

Estimated quantities and generator information are provided for proposal preparation and evaluation purposes. The City does not guarantee that all listed generators will require services throughout the contract term.

Generator Kw. Address Model Make Serial Number Volts

LS# 3 35 1801 Rosewood Dr. DGDB-5872326 CUMM G070082069 240

LS# 4 40 1399 West Ave. DGBC-5872322 CUMM G070082071 240

LS# 5 40 1140 Linton Ct. DGHD-7082204 CUMM D080173134 240

LS#6A 250 1154 Carrol St. DQDAA*2530613 CUMM A260521863 277/480

LS# 7 40 819 W. Desoto St. DGHD-7082204 CUMM D080173132 240

LS# 9 50 614 W. Lakeshore Dr. 50DGCA CUMM J960620550 240

LS# 10 30 Seminole & Ryan St. DSKCA-595071 CUMM E090004929 240

LS# 11 30 1984 Brantley Circle DSKCA-595071 CUMM E090004927 240

LS# 13 125 301 Crystal Lake Dr.

125DSHAE-

5864200 CUMM F070067822 240

LS# 14 30 512 Carrol St. DSKCA-595071 CUMM E090004928 240

LS# 15 100 295 Lake Minneola Dr. 100DGDB CUMM J960619601 240

LS# 16 40 180 W. Desoto St. DGHD-7082204 CUMM D080173135 240

LS# 17 50 142 Sunnyside Dr. DGBC-5872322 CUMM G070082070 240

LS# 18 50 575 E. Lakeshore Dr. 50.0DCA CUMM J960619886 240

LS# 23 80 590 North St. DSFAE5864199 CUMM F070067821 240

LS#31 WSFM 250 1201 W. Osceola St. LC5 CAT G5A01472 480

FIRE ADMIN 60 400 12th Street TP60-II-T2 TRADEWINDS 00016685 120

E-1 100 1151 North Ridge Blvd. 100.0DGFA CUMM J960619600 480

E-2 150 1401 North Ridge Blvd. 150.0DGFA CUMM J960619807 480

E-3 150 334 Citrus Tower Blvd. 150.0DGFA CUMM J9060619808 480

E-4 200 13410 Lake Wilma Rd. 200.0DFAA CUMM J960619833 480

E-5 200 13641 Gilbert St. 200 DFAA-84153 CUMM J960619834 480

E-6 450 13030 Hancock Rd. 450DFEC CUMM J96062087 480

E-7 150 2101 Kings Ridge Blv. 150.0GDFA CUMM J960619806 480

E-8 250 2302 Hartwood Marsh Rd. 250DFAC CUMM B980695119 480

E-8A 25 4242 Bokeelia Loop DKAF5602455 CUMM D030491269 240

E-9 250 13641 EMIL Jahna Rd. DFAC-4487919 CUMM J000159535 480

E-10 100 16834 Highway-50 100.0DGDB CUMM D980727045 480

E-11 60 13236 Whisper Bay Dr. 98A01891-5 OLY 2041110 480

E-12 40 12930 Magnolia Pointe

Blvd. 98A01890-S OLY 2041109 480

E-13 25 17450 Cobblestone Court. 98A01898-5 OLY 2041115 240

E-14 275 3115 US Highway 27 DFBF3374598 CUMM F990932950 480

E-15 275 14520 John Lake Rd. DFBF3374598 CUMM F990932951 480

E-16 150 1299 Summit Greens

Blvd. DGFA4476235 CUMM B000068644 480

E-17 230 1010 Jacks Lake Rd. 3306 CAT CAT 6YR03840 480

E-18 50 2835 Highland View

Circle DGCA-4488156 CUMM I000153096 240

E-19 125 1457 Lake Mist Lane 125DGEA-94979 CUMM D980727054 480

E-19A 80 1221 Legendary Blvd. DGCG5707961A CUMM C050761638 480

E-20 125 1292 N. Hancock Rd. DGEA4959458 CUMM G010071607 480

E-21 100 523-L Pitt Street 100.0DGDB CUMM J960619606 480

E-21A 25 301-L Pitt Street DKAF-7088163 CUMM D080170582 240

E-21B 125 800 Skyridge Rd. DGEA4959458 CUMM E010241686 480

E-22 80 3231 White Blossom Lane DGDA5549933 CUMM A020325200 240

E-22B 35 11827 Wind Flower Ct. DGGD556519 CUMM H020398225 240

E-23 40 12066 Still Meadows Dr. DDHD5693367 CUMM J040704026 240

E-24 230 4660 Barbados Loop DFAB5695070 CUMM K040714455 480

E-25 40 10614 Lake Louisa Road DGHD5702826 CUMM A050739866 240

E-26 35 838 Grand Highway DGBB-5872326 CUMM G070082068 240

E-27 35 4587 Barrister Dr. DGGD-7082202 CUMM D080173133 240

E-28 275 2835 Majestic Isle Dr. 275DFBF CUMM I930518939 480

E-29 125 2278 Caledonian Dr. DGEA5554670 CUMM D020354469 480

E-30 230 3644 Peaceful Valley

Drive DGFS5747272 CUMM A060870767 480

E-31 80 1903 Harrier Ave. DGCG5740501 CUMM I050832691 480

E-32 230 391 Balboa Blvd. DGFS57683307B CUMM F060940151 480

E-33 35 3605 Crestfield Blvd. DGBB5770158K CUMM G060951754 480

E34 250 3125 Heritage Hills Blvd. LC5 CAT GSA01608 480

E35 35 277 Giovani Blvd. DGGD-574918 CUMM B060882245 240

E36 100 11349 Lake Louisa Rd. DSGAA-7093421 CUMM E080184402 480

E37 100 626 South Ave. 100DGDB CUMM J960619896 480

E38 40 16700 Caju Rd. DSFAB7254971 CUMM J080213122 240

E39 100 2890 Hartwood Marsh Rd DSHAF-6157185 CUMM A080147281 480

E40 40 17645 Old HWY 50 DSFAB-1345437 CUMM A140627960 240

E41 60 16460 Good Hearth Blvd. DSFAD-1403534 CUMM C140658344 240

E42 200 700 Blackstill Lake Rd. D3GAE-1418468 CUMM K140764430 480

E43 25 3995 Grand Blossom Rd. C25D6 CUMM J150877923 480

E44 50 220 Camelot Loop C50D6 CUMM J160103866 240

E45 25 3403 Shallow Cove C25D6 CUMM E170188076 480

E46 50 14400 Hidden Court C50D6 CUMM E180360307 480

E47 40 22158 Valencia Blossom

ST C40D6 CUMM F170200061 240

E48 500 3151 Lost Lake Rd. DFEK-1910671 CUMM B190509695 480

E49 40 3435 Buoy Circle C40D6 CUMM B190501870 480

E50 40 3151 Crestwave Dr. C40D6 CUMM E190573366 240

E51 200 4419 Renly Lane C200D6D CUMM C210894052 480

E52 40 2345 Highland Ranch

Blvd. C40D6 CUMM I210981576 240

E53 40 4820 Fairwinds Ct. Winter

Garden, Fl. 34787 C40D6 CUMM D220071569 240

E54 500 2611 Five Mile Rd. DFEK2290696 CUMM J230278939 277

E55 50 2668 Jumping Jack Way C50D6C CUMM L220178667 277

E56 40 5741 Meditation Dr. C40-D6 CUMM D250436144 277

E57 80 4400 Willow Wood Ave. D80-8 CAT CAT00C44VCN601533 480

E58 60 3821 Island Blvd. D60-4LC CAT CAT00C44HCN400784 240

E59 60 3096 Namaste Dr. GDO3C2441935 CUMM E250446651 480

E60 80 3710 Crooked Vine Dr. C80 D6C CUMM E240336959 460

E61 80 11021 Gallica Rose C80 D6C CUMM G250474500 277

E62 125 2902 WoodCliff Lake C125 D6C CUMM I250516316 277

E63 40 2390 Arena Blvd C40 D6 CUMM A260520800 277

PORT.5352 55 3335 Hancock Rd. 5530KB15R ONAN 0672461517 240

PORT5375 50 3335 Hancock Rd. 50ROZJ-71 CUMM 376160 240

PORT.5377 62 3335 Hancock Rd. 60REOZJB KOHLER 2039970 240

PORT.5378 62 3335 Hancock Rd. 60REOZJB KOHLER 2039969 240

PORT.3300 300 3335 Hancock Rd. DF-3300SSK KOMATSU 3691261 480

PORT. 5526 340 3335 Hancock Rd. SR4B CAT BGK01740 120

PORT. 5528 182 3335 Hancock Rd. LC5 CAT G5A11301 240

PORT. 5529 182 3335 Hancock Rd. LC5 CAT G5A11478 240

PORT. 5530 182 3335 Hancock Rd. LC5 CAT G5A11582 240

PORT. 5376 50 3335 Hancock Rd. DGHE-5602081 CUMM D030488639 480

FS1 - 11gph 150 439 W. SR 50 GSJD30150S-UL JOHN DEERE OV -124566 120

FS2 - 5gph 60 2200 Hartwood Marsh rd. TP-60UL T/WINDS 22507 240

FS3 - 13 gph 180 2155 Legendary Way HDI180FT6U HI POWER 525101177 120

FS4 - 4 gph 50 13341 Hartle rd. D3400T-GEN1 GENERAC TP9E00216 240

PD1 - 43 gph 600 3600 US 27 2806C-E18TAG3 PERKINS JGDF5335N01883B 480

500K Bloxam Water

Tower 20 1102 Bloxam Ave. G00704211 GENERAC 3017690237 120

#1 Well / Greater

Hills 1280

15512 CHARTER OAKS

TR 1250RE0ZMB KOHLER 2201468 480

#2 Well / Greater

Hills 300 15534 ROYAL OAKS CT DFCB-5669593 ONAN D040628118 480

#3 Well / Hancock 350 3301 HANCOCK RD 350DFCC ONAN J960619216 277 /

#4 Well / East Tower 300 2190 EAST HWY 50 DFCB-5001427 CUMMINS J010292324 277 /

#5 Well / Sunburst 1000 2799 SUNBURST LANE DFHD-5748536 CUMMINS B-060890196 277 /

#6 Well / Heritage

Hills 300

3040 HERITAGE HILLS

BLVD DFCB-5669593 CUMMINS D040628117

277 /

#9 Well / EWWTP 400 3335 HANCOCK RD 400 CATERPILLAR CAT00C13KT3201247 480

Lab / EWWTP

Operations Building 1250 3335 HANCOCK RD DFLC-5006398 CUMM A020327954 480

Warehouse /

EWWTP 1000 3335 HANCOCK RD

DQFAD-

5938062 CUMM

A080147593

North Public Works 400 12842 Hancock RD SD400 GENERAC SD0400GG22125D18PPLY3 120

East Plant MCC 160 1500 3335 HANCOCK RD C 1500 D6E CUMMINS J240389065 277 /

3.5. Additional Repairs

If additional repairs are identified during maintenance, inspection, testing, or emergency service, the Contractor must notify the City's designated representative and provide a written estimate before performing the work.

The estimate must identify the generator location, description of the deficiency, recommended repairs, required parts and materials, estimated labor hours, applicable contract rates, total estimated cost, and anticipated completion timeframe.

No additional repair work may be performed without prior written authorization from the City.

All authorized repairs must be performed by qualified personnel at the applicable labor rates, parts pricing, and fees established in the Contractor's Price Proposal Form. Additional charges must receive prior written approval from the City.

Repair parts must be competitively priced at or below current industry list pricing. The City reserves the right to obtain alternate quotes for repair work when the proposed cost is considered excessive or unreasonable.

The Contractor must complete authorized repairs promptly to minimize generator downtime and confirm proper generator operation upon completion. Safety devices, guards, and protective components must not be removed or bypassed in a manner that compromises personnel or equipment safety.

3.6. Qualification Requirements

The Contractor must provide qualified technicians experienced in commercial generator maintenance, repair, diagnostics, and testing. Technicians assigned to City equipment must have at least five (5) years of relevant commercial generator experience.

The Contractor must:

A. Provide applicable certifications, licenses, manufacturer training, or factory-authorized service credentials demonstrating the qualifications of assigned personnel.

B. Identify the generator manufacturers and equipment that assigned technicians are qualified to service.

C. Submit technician resumes or qualification summaries for City review and approval before assigning personnel to City equipment.

D. Provide all necessary personnel, tools, diagnostic equipment, service vehicles, materials, and parts to perform the required services.

E. Assign a designated single point of contact responsible for scheduling, reporting, emergency coordination, and communication with City personnel.

F. Ensure that technicians wear identifiable company uniforms and appropriate personal protective equipment in accordance with applicable safety requirements.

G. Obtain City approval before assigning replacement technicians to perform services under the contract.

The Contractor must perform routine preventive maintenance, inspections, and general repairs using its own qualified employees. Subcontracting may be permitted for specialized services only with prior written approval from the City. The Contractor remains fully responsible for all work performed under the contract.

The Contractor must maintain adequate staffing, equipment, and resources to provide emergency services during equipment failures, severe weather events, and declared emergencies.

Emergency services must be provided in accordance with the response times and procedures proposed in the Contractor's Emergency Response Plan and accepted by the City. The accepted response-time commitments and Emergency Response Plan will become part of the resulting Contract.

An updated Emergency Response Plan must be submitted annually by April 1 and whenever material changes occur.

3.7. Invoicing and Payment Requirements

The Contractor must submit itemized invoices for services completed and accepted by the City.

Each invoice must identify the applicable Purchase Order number, generator location, generator identification, date of service, description of services performed, and applicable Contract pricing.

Each invoice must separately identify the maintenance services performed, including Full

Maintenance Service, secondary Preventive Maintenance Inspection (PMI), coolant flushing, belt replacement, load bank analysis, and fuel and oil analysis, as applicable.

Invoices must be accompanied by completed maintenance inspection checklists, field service reports, testing results, and other documentation required under this solicitation.

The Contractor must submit an updated maintenance schedule with each invoice identifying completed services, upcoming maintenance, and outstanding work in accordance with Section

3.2.

The City will only approve payment for services verified as completed and accepted. Invoices for incomplete services, unauthorized repairs, or services lacking required documentation will not be approved until the deficiencies have been resolved and a proper invoice has been submitted.

The Contractor must invoice at the applicable rates established in the Contract. Additional fees or charges not included in the approved Contract pricing must receive prior written authorization from the City.

The City will process proper invoices for services received and accepted in accordance with the

Local Government Prompt Payment Act, Sections 218.70 through 218.80, Florida Statutes, as applicable.

4. Response Format

PROPOSAL REQUIREMENTS

A response to this solicitation should address the requirements listed below in a clear, concise manner in the order stated herein. The response must detail how the proposed services best satisfy the City’s needs. The submitted proposal must follow the rules and format outlined within this section. Adherence to the rules will ensure a fair and objective analysis of all proposals.

Respondents must upload their proposal to the Portal in the format requested below (with each

“Tab” clearly identified).

All responses must be submitted and received by the deadline specified in this solicitation unless changed by Addenda. The responsibility for submitting the proposal on or before the stated date and time is solely that of the respondent. The City of Clermont will in no way be responsible for delays in transmittal or delays caused by any other occurrence. LATE

PROPOSALS WILL NOT BE ACCEPTED. Please allow sufficient time to submit the proposals.

PROPOSAL FORMAT

Proposals must contain the following documents, each fully completed and signed as required.

Proposals must be properly tabbed and include the information/documents specified in the applicable tab. All abbreviations and acronyms used in the response must be kept to a minimum and defined upon their first usage. Proposals that do not adhere to the following format or include the requested information/documents may be considered incomplete and, therefore, non-responsive.

To expedite the evaluation of responses, all respondents must follow the format and instructions provided herein. The City retains the option to reject any response that does not conform to the stated format requirements.

4.1. Proposal*

Instruction:

Respondents are limited to a total page count not to exceed sixty (60) pages, excluding the cover page, table of contents, and tab sheets. Page size shall be 8.5 x 11 inches. The text size should be 11 points or larger using Arial or Times New Roman font only. Use at least one (1) inch margins on the top and bottom and three-quarter (3/4) inch side margins. All response sections must be appropriately separated and tabbed. The City reserves the right to seek additional/supplemental representation on specific issues as needed.

The following are excluded from the page limitation: cover page, table of contents, tab sheets, required City forms, W-9, insurance documentation, licenses/certifications, local-preference documentation, and other required attachments or supporting exhibits.

Content:

Table of Contents

Outline in sequential order (as stated below) the major areas of the response. All pages must be consecutively numbered. Respondents must respond to all minimum requirements listed below.

Responses that do not contain such documentation may be deemed non-responsive.

A. Introduction Letter

1. Provide an introductory letter outlining the respondent’s specialization, the location of the office responsible for managing the contract, and a summary of the respondent’s experience and qualifications to perform generator maintenance and repair services.

The introduction letter must be signed by an authorized officer or representative of the company submitting the proposal.

B. License and Insurance

1. The respondent must provide evidence that the company is currently registered with the State of Florida. Include the active Florida Department of State Division of

Corporations Document Number (or registration number for fictitious names). If the respondent is an out-of-state or foreign corporation or partnership, the respondent must show evidence of being authorized to transact business in the State of Florida.

It is the respondent's responsibility to comply with all state and local business requirements. Include all applicable licenses required to perform the services outlined in this solicitation and a copy of the company's W-9.

2. Submit a current certificate of insurance (ACORD Form) showing the company's insurance coverage or a letter from the insurer confirming the company's ability to obtain the required coverage. Refer to the Proposal Procedures section for insurance coverage requirements and limits.

C. Company Background and Experience

1. The respondent must have been in business for at least five (5) years, providing generator maintenance and repair services or similar services. Provide a brief company history, including the date the company was established, years of experience, office locations, and an overview of the services provided.

2. Provide a brief description of the respondent's experience maintaining and repairing commercial generators, including experience with municipal utilities, public safety facilities, or other critical infrastructure. Identify the generator manufacturers, types, and capacities the respondent is qualified or authorized to service.

3. Provide a summary of up to five (5) similar contracts performed within the past five

(5) years, including contracts currently in progress. Include the client name, scope of services, approximate number of generators maintained, contract duration, and the respondent's responsibilities.

D. Personnel Qualifications and Technical Capability.

1. Identify the project manager, primary service technicians, and other key personnel proposed to perform the services outlined in the Statement of Work. Provide resumes or qualification summaries identifying their roles, years of experience, relevant certifications, manufacturer training, and technical qualifications.

2. Describe the respondent's technical capabilities, including experience servicing the generator manufacturers, models, and capacities identified in the City's generator inventory. Identify any factory-authorized service credentials or manufacturer-specific certifications held by the proposed personnel.

3. Provide a description of the staffing, service vehicles, diagnostic equipment, tools, and other resources available to perform scheduled maintenance, testing, and as-needed repairs.

4. Identify the individual who will serve as the City's primary point of contact responsible for scheduling, service coordination, reporting, and contract administration.

E. Maintenance Methodology and Approach

1. Provide a detailed description of the respondent's proposed approach to performing preventive maintenance, inspections, testing, and repair services in accordance with the Statement of Work.

2. Describe the process for developing, coordinating, and maintaining a service schedule for the City's generators, including procedures for tracking completed maintenance, upcoming services, and outstanding repairs.

3. Explain the respondent's approach to identifying equipment deficiencies, recommending corrective actions, minimizing generator downtime, and ensuring the quality and reliability of services performed.

4. Describe the procedures for communicating and coordinating with City personnel, including providing service updates, repair recommendations, and required documentation.

5. Provide samples of preventive maintenance checklists, field service reports, testing reports, and maintenance schedules used by the respondent.

F. Emergency Response Capability

1. Describe the respondent's ability to provide emergency generator maintenance and repair services during normal business hours, after hours, weekends, holidays, and declared emergencies.

2. Identify the location of the service facility responsible for responding to City requests and provide the proposed on-site response times, in hours, for routine, urgent, and emergency service calls.

3. Describe the personnel, service vehicles, diagnostic equipment, replacement parts, and other resources available to respond to emergency service requests.

4. Explain the respondent's procedures for prioritizing critical City facilities and maintaining service availability during hurricanes, severe weather events, extended power outages, or other declared emergencies.

5. Provide an Emergency Response Plan outlining emergency contact procedures, dispatch coordination, staffing availability, communication protocols, and procedures for responding to multiple service requests simultaneously.

G. References and Past Performance

1. Provide at least three (3) references for similar generator maintenance and repair contracts performed within the past five (5) years, preferably for municipalities, utilities, public safety facilities, or other critical infrastructure. Include the client name, contact person, telephone number, email address, contract period, approximate number of generators serviced, and a brief description of the services provided.

H. Cost Proposal

1. Complete and submit the City's Price Proposal Form provided as an attachment to this solicitation. All required pricing fields must be completed in accordance with the instructions provided in the form.

2. Pricing shall include all labor, materials, equipment, tools, transportation, overhead, and other costs necessary to perform the services outlined in the Statement of Work, unless otherwise identified as a separate line item in the Price Proposal Form.

3. The completed Price Proposal Form must be submitted in its original Excel format.

Respondents shall not modify the pricing structure, estimated quantities, formulas, or format of the provided document. Any additional pricing information or clarification shall be submitted separately.

I. Business Location

To be considered a respondent located within the City of Clermont and eligible to receive up to five (5) additional evaluation points, the respondent must provide documentation demonstrating all of the following:

1. Physical business location within the City of Clermont.

Provide one (1) or more of the following showing the respondent's City of Clermont address:

a. Executed commercial lease, or deed/property record (if owned).

b. A recent utility bill in the business name at the Clermont address.

c. Certificate of Occupancy or zoning approval for the Clermont site (if applicable).

d. SunBiz (Florida Division of Corporations) records listing the Clermont principal/branch address.

2. Continuous operations at that location for at least one (1) year.

Provide documents showing the same Clermont address over time (recommend items showing two dates spanning 12+ months), such as:

a. Twelve (12) months of lease history (executed lease + renewal, rent ledger, or notarized landlord letter confirming occupancy dates).

b. Utility bills (one dated at least 12 months prior and one current).

c. Insurance certificates or policy declarations showing the Clermont address from last year and the current year.

d. State/local filings or registrations listing the Clermont address over the past year.

3. Lawful business activity within the City during the preceding one (1) year.

Provide one of the following from the last twelve (12) months:

a. Receipt/statement showing payment of commercial real property taxes for the

Clermont property (if owned).

b. Proof of filing the Tangibles Personal Property Tax Return with Lake County/Tax

Collector.

c. Other documentation demonstrating lawful business activity, such as local permits tied to the Clermont address (if applicable) or occupational license/business license documents listing the Clermont address.

*Response required

4.2. Vendor Information & W-9*

Please download the Vendor Information form, complete it, and upload it with a copy of your W-

9.

• Vendor_Information.pdf

*Response required

4.3. State of Florida Certificate*

Upload State of Florida Department of State Certificate

*Response required

4.4. Conflict of Interest Disclosure*

I HEREBY CERTIFY that:

A. I, the Individual submitting this response, am a duly authorized representative of the firm

(Respondent), and I possess the legal authority to make this affidavit on behalf of myself and the firm for which I am acting and,…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .