GASNT Storage SON.docx

DOCX document 17 KB Posted

Attached to
climate-controlled storage container Federal contract opportunity
Solicitation number
FA460023Q0057
Issued by
Department of the Air Force Air Combat Command

About this file

This statement of need outlines requirements for three climate-controlled storage containers to house Global Aircrew Strategic Network Terminal systems for the 55th Space Control Squadron. The 20-foot long containers must have 125-amp interior panels with 60-amp exterior disconnects capable of handling three-phase 208-volt/60-hertz power with 20 amps per phase. Additional requirements include duplex GFI outlets, interior LED lighting, spray foam insulation on the floor and sides, a 15,000 BTU HVAC unit, and a personnel door on one side. The solicitation from the Department of the Air Force Air Combat Command seeks these three climate-controlled storage containers to meet the specifications laid out in the statement of need.

View the file

Other files for this federal contract opportunity

Other files attached to climate-controlled storage container, newest first.
File Type Posted
52.212-1.docx DOCX document
Solicitation Amendment FA460023Q00570001 SF 30.pdf PDF
GASNT contractor Qs As.docx DOCX document
Solicitation Amendment - FA460023Q00570001.pdf PDF
52.212-1.docx DOCX document
Solicitation - FA460023Q0057.pdf PDF
Wage Determinations.pdf PDF
52.212-2.1689179177116.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF NEED

55th SCS Global Aircrew Strategic Network Terminal (G-ASNT) Storage Containers

1. This requirement is to purchase three (3) 20’ long climate-controlled storage containers that will be used to house the transportable G-ASNT systems. There currently is no capability to store the systems and their additional increments that will be delivered. The containers must be fabricated in such a way in order to meet system and technician specifications.

2. The provided items furnished shall meet or exceed the following requirements:

a. 125A interior panel w/60A exterior disconnect, capable of 3 phase 208v/60Hz w/20A per phase.

b. One Duplex GFI Outlet.

c. Interior Overhead Lighting, 2x 4’ LED light fixtures.

d. Spray foam on the floor underneath wood flooring and Styrofoam insulation on the sides and the top of the container.

e. 15K BTU HVAC Unit.

f. Personal man-door on the side of the container (in addition to the main cargo doors).

Item Description
Item Number
Quantity
Vendor & Source
Climate-Controlled Storage Container
n/a
3 Ea
TBD

3. Contractor shall provide products that meet or exceed the requirements above.

File details come from the government source that posted it. Updated .