This document contains an equipment list for maintenance and service of medical lasers and imaging equipment at Womack Army Medical Center. The list includes 17 items from various manufacturers requiring preventative maintenance and repair services. Response times are required within 8-5 hours for medical imaging equipment, including two Siemens gamma cameras and two Siemens Cath Lab units. The document relates to the pre-solicitation notice for an annual maintenance and service contract with the Department of the Army Medical Command to provide continued upkeep and repairs on the listed lasers and imaging systems to ensure they remain fully operational. Preventative maintenance and repair work is included for some laser models but excluded for others, with consumables also excluded from coverage for several items. Loaner equipment may be available based on the contractor's inventory.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B.01 Synopsis W91YTZ23Q0067.doc | DOC document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Equipment Maintenance
| Item # |
| Manufacturer |
| Description |
| Qty |
| Model |
| Serial Number |
| PM/ Year |
| Current Contract Expiration Date |
Location : Army – MEDCOM – Womack Army Medical Center
| 4401729 | |
| Cutera | |
| Laser | |
| 1 | CoolGlide Xeo |
Included Coverage
| XN13571 |
| 1 |
Excluded Coverage
YAG lasers limited to 1 replacement per year Handpieces
| 4401732 | |
| Lumenis | |
| Laser | |
| 1 | Selecta II |
| 10379 | |
| 1 |
Included Coverage
Excluded Coverage
Laser tube
Consumables/supplies Scanner replacement
| 4401734 | |
| Candela | |
| Laser | |
| 1 | VBeam Perfecta |
| 9914-0300-3184 | |
| 1 |
Included Coverage
Excluded Coverage
| Limited to 1 (twelve) pack of cryogen - 1,000 gram canister Limited to 1 dye kit per year |
| Consumables such as fibers, delivery systems and sliders |
| 4401735 | ||
| Candela | ||
| Laser | ||
| 1 | GentleMax Pro | 9914-9035-8113 |
| 2 |
| Included Coverage |
| Excluded Coverage |
Limited to (2) Laser head replacements per year Calibration Verification during PM Limited to (2) PM Kits Accessories/consumables such as cryogen cannisters, delivery system components (includes fiber, handpiece, slider, DCD delivery system) Distance gauges and output windows, eyewear
| 4401736 | ||
| Carl Zeiss Meditec | ||
| Laser | ||
| 1 | Visulas 532s | 1198201 |
| 1 |
Excluded Coverage
Consumables-bulbs, flash tubes, lamps, filters, test chambers, test eyes and test fixtures Laser head
| 4401738 | |
| Alcon | |
| Femto Laser | |
| 1 | LenSx |
| 0417-A265 | |
| 1 |
Included Coverage
Excluded Coverage
| Repair only on laser engine components | Complete Laser Engine replacement | |
| Annual recertification | Fiber optics and indirect or LIO Disposables/consumables |
| Item # |
| Manufacturer |
| Description |
| Qty |
| Model |
| Serial Number |
| PM/ Year |
| Current Contract Expiration Date |
4401739 Lumenis Sub Items Moses
Qty 1
Model Surgical Laser Serial 1 Pulse P120H Included Coverage Laser tube
| 359 |
| 2 |
Excluded Coverage Consumables or accessories items including PiQ04 dye IPL/Lightsheer device packs
| 4401749 | |
| TOPCON | |
| Laser | |
| 1 | PASCAL |
| OMC-242 | |
| 1 |
Excluded Coverage
Consumables/supplies, fiber optics, and indirect LIO
| 4401751 | |
| Boston Scientific | |
| Laser | |
| 1 | Greenlight XPS |
| XPS60214 | |
| 2 |
Included Coverage
Excluded Coverage
Laser Head
Field change orders Loaners
| 4401752 | |
| Lumenis | |
| Laser | |
| 1 | UltraPulse Encore |
| 1211 | |
| 2 |
Included Coverage
Excluded Coverage
Laser tube Ultrascan handpiece
Accessories, consumables
| 4493986 | |
| Alcon | |
| Femto Laser | |
| 1 | LenSx |
| 1025-4-1061 | |
| 1 |
Included Coverage
Excluded Coverage
| Repair only on laser engine components Annual recertification |
| Complete Laser Engine replacement Fiber optics and indirect or LIO Disposables/consumables |
| 4493987 | ||
| Alcon | ||
| Femto Laser | ||
| 1 | LenSx | 1016-3-1096 |
| 1 |
| Included Coverage |
| Excluded Coverage |
| Repair only on laser engine components Annual recertification |
| Complete Laser Engine replacement Fiber optics and indirect or LIO Disposables/consumables |
| 4494001 | ||
| Siemens | ||
| Gamma Camera | ||
| 1 | Symbia Evo | 1260 |
| 2 |
| Included Coverage |
| Excluded Coverage |
Crystal hydration SPECT detector head subsystem Cracked Crystals Consumables/Supplies
Service must be preformed by Remi designated vendor 8x5 coverage 6-12 Hour response time
| 4494002 | |
| Siemens | |
| Cath Lab | |
| 1 | Artis Q |
| 109697 | |
| 2 |
| Sub Items |
| Qty |
| Model |
| Serial |
| Included Coverage |
| X-RAY TUBE ASSEMBLY |
| 1 |
| 649231971 |
| X-ray Tubes |
| X-RAY GENERATOR |
| 1 |
| 2826 |
| Detectors |
| X-RAY GENERATOR |
| 1 |
| X-RAY GENERATOR |
| 1 |
| 4551 |
| Large display monitor |
8x5 coverage 6-12 Hour response time
4497927 IRIDEX
Laser
| 1 | Cyclo G6 | IQI91604C |
| 1 |
Included Coverage Fiber damage Limited to (1) diode per year Shipping charges Depot service Loaners based on availability
Excluded Coverage Consumables/Supplies Accessories (including, but not limited to foot pedals, smart keys, safety eyewear, carry case, etc)