WHEN SHOWN ON DRAWINGS,

PLACE SUBGRADE REINFORCEMENT

TO A DEPTH OF 1 FT.

Cf_ GRADE pROFILE

EXISTING

G� it--.

G3

� \ � H AVERAGE i..--- ---

B

CREST

ROLLING DIP CONSTRUCT/ON NOTES:

1. THE CROSS SLOPE OF THE ROADBED SHALL BE

MAINTAINED THROUGH THE DIP.

2. THE DRAIN LINE SHALL BE PERPENDICULAR TO

THE CENTER LINE OF THE ROADBED.

3. PLACE CLASS II OUTLET RIPRAP WHEN SHOWN ON

THE DRAWINGS. REFER TO OUTLET RIPRAP DETAIL

BELOW.

4. FOR DIPS ON AGGREGATE SURFACED ROADS,

REDUCE (H) DEPTH BY 0.2 FT.

5. WATERBAR AND DIP CONSTRUCT/ON TOLERANCES

SHALL BE IN ACCORDANCE FP-03

SUPPLEMENTAL SPECIFICATION 204.13(d);

TOLERANCE CLASS A.

6. SUBGRADE REINFORCEMENT MATERIAL SHALL BE

CONSIDERED INCIDENTAL TO DIP CONSTRUCT/ON.

" H .,c:,z,...-

E

A A

DRAIN LINE

PROFILE VIEW

t

B

ROLLING DIP CONSTRUCT/ON

DIMENSIONS

TYPE H (DRIVEABLE WATERBAR)

% LENGTH DEPTH (H)

PROFILE

OUTSIDE INSIDE

GRADE A B EDGE EDGE

0 TO 4 6' 10' 1.5' 0.8'

5 TO 8 6' 10' 1.5' 0.8'

9 TO 12 6' 12' 1.5 0.8'

13 TO 16 7' 15' 1.0' 0.8'

17 & OVER 7' 20' 1.0' 0.8'

OUTLET RIPRAP

1 FT. DEPTH IN AREAS WITHOUT A

(3.0 C.Y.)

FILL SLOPE, EXTEND

RIPRAP TO DAYLIGHT.

A� MINIMUM GRADIENT SHALL

L_ �

BE 6 % OUTSLOPE.

...__ _ __,""">ll7:====-____;:�.� �-L -6,:t

�''(,A�/// /2

�1.5:1 OR

1//////'-'/('<,� , AS EXISTS

SUBGRADE

CROSS SECTTON �EW PLAN VIEW

ROLLING DIP AND

WATER BAR TYPICAL

., r

DESIGNED:

DRAWN:

CHECKED:

ROLLING DIP CONSTRUCT/ON DIMENSIONS

PROFILE

GRADE

0 TO 4

5 TO 6

7 TO 8

9 TO 10

1.

CONST. GRADE DEPTH REINFORCEMENT

LENGTH CUBIC

G1 G2 G3 (H) (E) YARDS

-7 2 -6 0.6' 20'

-10 2 -9 0.6' 20'

-13 2 -12 0.5' 20'

-16 2 -15 0.5' 30'

OVER 10 % NOT RECOMMENDED

REINFORCEMENT GRADATION

SIEVE SIZE

12" 2"

3/4" # 200

% PASSING

100% 20-80% 0-40% 0-10%

WATERBAR CONSTRUCT/ON NOTES:

WATERBARS ARE USUALLY CONSTRUCTED BY

ANGLE DOZERS. WATERBARS SHALL HAVE A

CLEAN OUTLET AND BE CONSTRUCTED SO THEY

WILL NOT FAIL THROUGH ALL WEATHER USE.

2. THE WATERBAR DRAIN LINE SHALL BE SKEWED

5· TO 25".

3. WATERBARS SHALL BE CONSTRUCTED SO THAT

ORA/NL/NE EXCAVATION IS APPROXIMATELY 6"

INTO SOLID SOIL AND THE TOP OF COMPACTED

WATERBAR IS 12" ABOVE THE ORA/NL/NE.

4. THE TOTAL LENGTH OF THE WATERBAR SHALL

NOT BE LESS THAN SIXTEEN FEET (16') .

5. CROSS SLOPE OF THE DRAIN LINE SHALL BE

EQUIVALENT TO TO THE CROSS SLOPE OF THE

ROAD PLUS TWO PERCENT (2%).