FR2019 - D5 Montmorency Otsego Oscoda List ACM reports.pdf

PDF 3 MB Posted

Attached to
751/19360. AGY Various Counties - Demo and Asbestos Abatement
Solicitation number
RFQ 171 190000000547 4
Issued by
Monroe County, Michigan

About this file

This is an Asbestos Containing Material (ACM) and Hazardous Materials Inspection Report prepared by Red Cedar Consulting for the Michigan Department of Natural Resources Forest Resources Division. The report documents comprehensive ACM and hazardous materials inspections completed at multiple properties across Montmorency, Otsego, and Oscoda counties in Michigan during September 2018. The inspections were conducted to comply with United States Environmental Protection Agency (USEPA) National Emissions Standards for Hazardous Air Pollutants (NESHAP) requirements under 40 CFR Part 61 and Occupational Safety and Health Administration (OSHA) Asbestos Standards for Construction under 29 CFR 1926.1101. The inspections included visual assessments and sampling of suspect ACM materials at multiple residential properties, including cabins, mobile homes, and associated outbuildings. Samples were collected and submitted to APEX Research Inc. Laboratories for analysis using Polarized Light Microscopy (PLM), the EPA-approved method for identifying asbestos in bulk materials.

The inspection results identified Category I and Category II non-friable ACM at specific properties requiring remediation prior to any demolition or renovation activities. Category I ACM consisting of rolled roofing materials containing up to 10% Chrysotile asbestos was identified at Steven's property in Otsego County (30 square feet), while Category II ACM including roof coating containing up to 20% Chrysotile asbestos (320 square feet) and cementatious Transite board containing up to 25% Chrysotile asbestos (10 square feet) was identified at the Gombos Trailers property in Montmorency County. No friable ACM was identified during the inspections. Hazardous materials identified at the Gombos Trailers property included one thermostat, a quart container of miscellaneous oil, and a 100-pound propane cylinder, all requiring proper removal and disposal. The report requires notification to the Michigan Department of Environmental Quality Air Quality Division and submission of Intent to Renovate/Demolish forms to MIOSHA-Asbestos Program at least ten working days prior to any renovation or demolition activities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOTS Name County TWP Sec T/R Site Access Description # Buildings Bldg Desc. Photos

Dilks lease A-133 Oscoda Big Creek Section 3 NENE T26N R1E behind Parmalee State Forest Campground house, pole bldg, storage bldg, well

124885 Stevens Otsego Charlton Sec 12 SW 1/4 NE 1/4T31N R 01W Sawdust pile rd to road 96 cabin & 4 outbuildings 5 486 May-16

Pigeon River Country

2044775 Gombos Trailers Montmorency Vienna Twp Sec 34 SE 1/4 NE 1/4T31N R01E off end Island Hill Rd mobile home, 2 travel trailers, outhouse 4 664 42491 Atlanta 8

Buck residence Montmorency Vienna Twp Sec29 T31N R01E Huff Rd residence 3 1700 + 980 +38418-Jan Atlanta

Rack N Fin Montmorency Montmorency Sec 32 T32N R01E Camp 30 hunt camp 5 1472 +20+66+64+1218-Jan Atlanta

DNR-FRD Demo Pkg FR2019 D5 Montmorency Otsego Oscoda Counties

P.O. Box 13216

Lansing, MI 48901

Phone: 888.449.4566

Fax: 888.448.8739 www.redcedarconsulting.net

September 28, 2018

Ms. Sharon Conley

Forest Resources Division Facilities & Equipment Coordinator

P.O. Box 30452

Lansing, MI 48909

RE: Asbestos Containing Material and Hazardous Materials Inspection

Otsego County, MI

Parcel ID: Steven’s 40

Dear Ms. Conley:

Red Cedar Consulting has completed an asbestos-containing material (ACM) and hazardous materials inspection at Steven’s 40 Otsego County, Michigan (Subject Property). This inspection was completed at the request of the Michigan Department of Natural Resources to comply with the United States Environmental Protection Agency (USEPA) requirements for demolition and renovation set forth under the National Emissions Standards for Hazardous Air Pollutants (NESHAP, 40 CFR Part 61). This inspection was also completed to comply with the Occupational Safety and Health Administration

(OSHA) Asbestos Standards for Construction (29 CFR 1926.1101) which limits employee exposure to asbestos.

SUBJECT PROPERTY

The Subject Property is comprised of a residential parcel which contains a cabin shed and outhouse (the

Buildings).

VISUAL INSPECTION AND SAMPLING

Asbestos Containing Materials Inspection

Aaron Paquet of Red Cedar Consulting (Red Cedar), accredited State Of Michigan/EPA Asbestos

Building Inspectors (Accreditation Number A30955) who completed training per the Michigan Asbestos

Workers Accreditation Act 440, completed an inspection of the Subject Property on September 14, 2018 for suspected asbestos containing building materials.

This inspection, and subsequent sample collection was completed in accordance with the USEPA

Asbestos Hazard Emergency Response Act (AHERA) (40 CFR Part 763) assessment and sampling protocol.

Project No.: 18-1116

Michigan Department of Natural Resources

During the completion of the inspection, each area of the Subject Property was visually inspected for asbestos containing building materials (ACBM). Following the completion of the visual inspection, Red Cedar staff identified each suspect area of friable and non-friable ACBM and sorted them into one of three homogenous categories for sampling purposes. AHERA defines friable as a material that when dry, may be crumbled, pulverized, or reduced to powder by hand pressure. A homogenous area is defined by OSHA as an area of surfacing, thermal system insulation (TSI) or miscellaneous material that is uniform in color and texture. Surfacing materials are most commonly found in sprayed-on, troweled-on or otherwise applied to surfaces, such as acoustical plaster on ceilings and fireproofing materials on structural members. TSI refers to materials applied to pipes, fittings, boilers, ductwork, or other components to prevent heat loss or gain, or condensation. Any material that does not fall under the surfacing or TSI category, such as floor tile, drywall, and acoustical ceiling tile are placed into the miscellaneous materials category.

Following the completion of the visual inspection, Red Cedar staff identified the following materials as suspect ACBM:

• Asphalt Shingle

• Rolled Roofing

• Glazing

Red Cedar staff collected six samples of suspect ACBM separated into three distinct homogenous groups for laboratory analysis. Samples were collected and submitted to APEX Research Inc. Laboratories

(APEX) (Accreditation Number 102118-0) for laboratory analysis. Analysis was completed utilizing polarized light microscopy (PLM) which is the Environmental Protection Agency (EPA) approved method for analysis of bulk materials for asbestos. PLM analysis completed pursuant to method (EPA 600/M4-82-020) identifies asbestos fiber bundles by the visual properties displayed when the sample is treated with various dispersion staining liquids. The laboratory report completed following the sample analysis indicates if asbestos is present, and at what percentage along with a description and percentage of other fibrous and non-fibrous materials and sample color. Chain-of-custody documentation was followed from sample collection through shipping and receiving of the samples at the designated laboratory. The documentation assures that samples will meet the quality assurance/quality control measures defined by AHERA. The laboratory analytical report prepared by APEX for the six samples is included as

Attachment A.

Hazardous Materials Inspection

On September 14, 2018 the Subject Property was also inspected for the presence of hazardous materials which include but are not limited to polychlorinated biphenyls (PCBs) and potential mercury containing equipment and any items or containers that may contain or be classified as a hazardous or regulated material. Each material, if identified, was documented along with the approximate location. Any materials identified as hazardous are included in Table 1.

INSPECTION RESULTS AND RECOMMENDATIONS

During the completion of the asbestos inspection, six samples of suspect ACM were collected and are documented in Table 2 along with the Red Cedar sample number, description, friability, material type, ACM classification, sample location, material quantity and laboratory analytical results. A Site Diagram was prepared which provides the general building layout and sample locations and is included as

Attachment B.

ACM, as defined by the USEPA NESHAP is “any material containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763 Section 1, Polarized Light Microscopy”.

Friable ACM is defined by NESHAP as any material containing more than 1 percent asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Friable ACM is a concern due the ease of unintentionally disturbing the ACM which may result in “visible emissions” which is known as a Fiber Release Episode.

Non-friable asbestos-containing material is defined as “material containing more than 1 percent asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Non-friable

ACM’s are separated into Category I and Category II ACM. Category I ACM is any asbestos containing packing’s, gaskets, resilient floor coverings (vinyl floor tile and linoleum are examples of these) and asphalt roofing products. Category II ACM is stated by NESHAP as any material excluding Category I non-friable ACM such as drywall, plaster or fiberboard insulation.

Presumed Asbestos Containing Material

Presumed Asbestos Containing Materials (PACM) are suspect surfacing, TSI and miscellaneous materials found in buildings constructed prior to 1980 which are classified as and due to the age of the structure, are assumed to be ACM and do not require sample collection and analysis. OSHA dictates that PACM may be “rebutted” following a complete inspection pursuant to AHERA protocol.

No PACM was identified during the completion of this inspection. All suspect materials identified were sampled and analyzed for ACM.

Table 3 lists the location, material description, friability, condition, material type (surfacing, thermal or miscellaneous) and approximate quantity of all PACM documented at the Subject Property.

Table 4 provides a summary all ACM documented at the Subject Property which includes the material location, description, and approximate quantity.

Friable ACM’s

No friable ACM’s were identified during the completion of this inspection.

Category I ACM

Rolled roofing samples collected from the Outhouse during the completion of the inspection were found to contain up to 10% Chrysotile asbestos. The assessment to quantify the extent of this material identified

30 sq. ft. of asphalt roofing materials on the Building.

Category II ACM

No Category II non-friable ACM was identified during the completion of this inspection.

RECOMMENDATIONS

Asbestos Containing Materials

The Category I roofing materials are non-friable ACM’s that may be left in place as long as the demolition/renovation activities are completed following the OSHA Asbestos Standards for Construction

(29 CFR 1926.1101) which limits employee exposure to asbestos.

Please note: The location of samples obtained during this inspection were in a random fashion and areas that were not identified during this inspection may be damaged or have become damaged since the inspection was completed. If Category I or Category II friable materials are discovered prior to or during the demolition/renovation process, these materials must be abated prior to commencement of any demolition/renovation activities at the Subject Property.

Hazardous Materials

No Hazardous Materials were identified at the Subject Property.

REGULATORY REQUIREMENTS

A Notification of intent to Renovate/Demolish form must be filed with the Michigan Department of Environmental Quality- Air Quality Division at least 10 working days prior to any renovation or demolition activities at a site.

The Notification of Intent to Renovate/Demolish form must also be completed and submitted to the

MIOSHA-Asbestos Program whenever demolition, encapsulation and/or renovation activities at a site involving greater than ten lineal feet and/or fifteen square feet of ACM will be completed.

Regulated asbestos containing materials per NESHAP (40 CFR Part 61) which falls into any of the following categories are ACM’s that must be removed prior to any renovation/demolition activities at the

Subject Property.

• Friable asbestos material.

• Category I non-friable ACM that has become friable.

• Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

• Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of renovation or demolition operations.

Asbestos abatement should only be performed by a certified asbestos abatement contractor licensed to complete abatement work. The contractor must also follow the standards and requirements set forth per the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) and the USEPA NESHAP (40 CFR Part 61).

Additional information regarding the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) and the USEPA NESHAP (40 CFR Part 61) can be obtained by contacting the associated agency below.

NESHAP Asbestos Program MIOSHA-CSHD-Asbestos Program

Department of Environmental Quality State of Michigan Phone: 517-284-6777 Phone: 517-284-7680

Email: asbestos@michigan.gov

DISCLAIMER

Red Cedar Consulting performed destructive testing methods in an attempt to access and inspect all areas of the Building. Unfortunately, due to the age of construction along with multiple additions/renovations that may have been completed on the Building, additional inspections may be required if suspect ACM material not documented within this report is encountered during renovation/demolition activities.

This report was prepared at the request and for exclusive use by the Michigan Department of Natural

Resources and may not be reproduced or sold without written permission from Red Cedar Consulting.

We appreciate the opportunity to provide the requested services. Please contact us at (888) 449-4566 with any questions or concerns.

Sincerely, Red Cedar Consulting

Aaron Paquet

Michigan/EPA Certified Asbestos Building Inspector

(A30955)

©2018 Red Cedar Consulting, LLC.

Phone: 888.449.4566

Facilities & Equipment Coordinator

Montmorency County, MI

Parcel ID: Gombos Trailers inspection at Gombos Trailers Montmorency County Michigan (Subject Property). This inspection was completed at the request of the Michigan Department of Natural Resources to comply with the United States Environmental Protection Agency (USEPA) requirements for demolition and renovation set forth under the National Emissions Standards for Hazardous Air Pollutants (NESHAP, 40 CFR Part 61). This inspection was also completed to comply with the Occupational Safety and Health Administration

The Subject Property is comprised of a residential parcel with two mobile homes, a travel trailer and outhouse (the Buildings).

Darrell DeMasters of Red Cedar Consulting (Red Cedar), accredited State Of Michigan/EPA Asbestos

Building Inspectors (Accreditation Number A31159) who completed training per the Michigan Asbestos

Workers Accreditation Act 440, completed an inspection of the Subject Property on September 20, 2018

During the completion of the inspection, each area of the Subject Property was visually inspected for asbestos containing building materials (ACBM). Following the completion of the visual inspection, Red Cedar staff identified each suspect area of friable and non-friable ACBM and sorted them into one of three homogenous categories for sampling purposes. AHERA defines friable as a material that when dry, may be crumbled, pulverized, or reduced to powder by hand pressure. A homogenous area is defined by OSHA as an area of surfacing, thermal system insulation (TSI) or miscellaneous material that is uniform in color and texture. Surfacing materials are most commonly found in sprayed-on, troweled-on or otherwise applied to surfaces, such as acoustical plaster on ceilings and fireproofing materials on structural members. TSI refers to materials applied to pipes, fittings, boilers, ductwork, or other components to prevent heat loss or gain, or condensation. Any material that does not fall under the surfacing or TSI category, such as floor tile, drywall, and acoustical ceiling tile are placed into the

Following the completion of the visual inspection, Red Cedar staff identified the following materials as

• Roof Coating

• Fiberboard

• 9x9 Vinyl Floor Tile

• Linoleum

• 12x12 Vinyl Floor Tile

• Transite Panel

Red Cedar staff collected thirty two samples of suspect ACBM separated into fifteen distinct homogenous groups for laboratory analysis. Samples were collected and submitted to APEX Research Inc.

Laboratories (APEX) (Accreditation Number 102118-0) for laboratory analysis. Analysis was completed utilizing polarized light microscopy (PLM) which is the Environmental Protection Agency (EPA) approved method for analysis of bulk materials for asbestos. PLM analysis completed pursuant to method (EPA 600/M4-82-020) identifies asbestos fiber bundles by the visual properties displayed when the sample is treated with various dispersion staining liquids. The laboratory report completed following the sample analysis indicates if asbestos is present, and at what percentage along with a description and percentage of other fibrous and non-fibrous materials and sample color. Chain-of-custody documentation was followed from sample collection through shipping and receiving of the samples at the designated laboratory. The documentation assures that samples will meet the quality assurance/quality control measures defined by AHERA. The laboratory analytical report prepared by APEX for the thirty two samples is included as Attachment A.

On September 20, 2018 the Subject Property was also inspected for the presence of hazardous materials which include but are not limited to polychlorinated biphenyls (PCBs) and potential mercury containing equipment and any items or containers that may contain or be classified as a hazardous or regulated

During the completion of the asbestos inspection, thirty two samples of suspect ACM were collected and are documented in Table 2 along with the Red Cedar sample number, description, friability, material type, ACM classification, sample location, material quantity and laboratory analytical results. A Site Diagram dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Friable ACM is a concern due the ease of unintentionally disturbing the ACM which may result in “visible emissions” which is known as a Fiber Release Episode.

Non-friable asbestos-containing material is defined as “material containing more than 1 percent asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Non-friable

ACM’s are separated into Category I and Category II ACM. Category I ACM is any asbestos containing packing’s, gaskets, resilient floor coverings (vinyl floor tile and linoleum are examples of these) and asphalt roofing products. Category II ACM is stated by NESHAP as any material excluding Category I found in buildings constructed prior to 1980 which are classified as and due to the age of the structure, are

No PACM was identified during the completion of this inspection. All suspect materials identified were sampled and analyzed for ACM.

Table 3 lists the location, material description, friability, condition, material type (surfacing, thermal or

No friable ACM’s were identified during the completion of this inspection.

No Category I ACM’s were identified during the completion of this inspection.

Roof Coating samples collected from the Green Trailer Roof during the completion of the inspection were found to contain up to 20% Chrysotile asbestos. The assessment to quantify the extent of this material identified 320 sq. ft. of roof coating materials on the Building.

The cementatious “Transite” board located behind the stove in the Silver Trailer was found to contain up to 25% Chrysotile asbestos. The visual assessment to quantify the extent of this material identified 10 sq.

ft. of cementatious (Transite) board in the Building.

Roof Coating identified on the exterior of the Building must be abated prior to completion of any renovation/demolition activities at the Subject Property. Any Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of renovation or demolition operations must be properly abated.

Transite board was identified in the interior of the Silver Trailer and must be abated prior to completion of any demolition activities at the Subject Property. In demolition, all cementatious ACM must be removed prior to demolition due to the likelihood of becoming regulated due to the demolition process.

Please note: The location of samples obtained during this inspection were in a random fashion and areas inspection was completed. If Category I or Category II friable materials are discovered prior to or during

Hazardous Materials identified at the Subject Property and documented in Table 1 which require proper removal and disposal consist of the following items:

• Thermostat (1)

• Quart Container Misc. Oil

• 100 lb Propane Cylinder involving greater than ten lineal feet and/or fifteen square feet of ACM will be completed.

Regulated asbestos containing materials per NESHAP (40 CFR Part 61) which falls into any of the following categories are ACM’s that must be removed prior to any renovation/demolition activities at the

• Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

• Category II non-friable ACM that has a high probability of becoming or has become crumbled, complete abatement work. The contractor must also follow the standards and requirements set forth per

Red Cedar Consulting performed destructive testing methods in an attempt to access and inspect all areas of the Building. Unfortunately, due to the age of construction along with multiple additions/renovations

We appreciate the opportunity to provide the requested services. Please contact us at (888) 449-4566

Attachment A

APEX Research Laboratory Analytical Results

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 01 Asbestos Present: NO Cellulose - 5%

Cust. #: GT-HM-01A No Asbestos Observed Other - 95% Material: Black Roof Coat Location:

Appearance: black,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 79834 - 02 Asbestos Present: NO Cellulose - 2% Cust. #: GT-HM-01B No Asbestos Observed Other - 98% Material: Black Roof Coat Location:

Appearance: black,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 79834 - 03 Asbestos Present: NO Cellulose - 5% Cust. #: GT-HM-01C No Asbestos Observed Other - 95% Material: Black Roof Coat Location:

Appearance: black,fibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

Project : Gombos Trailers

NVLAP Lab Code 102118-0

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189

(734) 449-9990, Fax (734) 449-9991 Page 1 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 04 Asbestos Present: NO Fiberglass - 30%

Cust. #: GT-HM-02A No Asbestos Observed Other - 70% Material: Asphalt Shingle Location:

Appearance: black,fibrous,homogenous Layer: 1 of 2

Lab ID #: 79834 - 04a Asbestos Present: NO Fiberglass - 50% Cust. #: GT-HM-02A No Asbestos Observed Other - 50% Material: Felt Location:

Appearance: black,fibrous,homogenous Layer: 2 of 2

Lab ID #: 79834 - 05 Asbestos Present: NO Fiberglass - 30% Cust. #: GT-HM-02B No Asbestos Observed Other - 70% Material: Asphalt Shingle Location:

Appearance: black,fibrous,homogenous Layer: 1 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 2 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 05a Asbestos Present: NO Fiberglass - 50%

Cust. #: GT-HM-02B No Asbestos Observed Other - 50% Material: Felt Location:

Appearance: black,fibrous,homogenous Layer: 2 of 2

Lab ID #: 79834 - 06 Asbestos Present: NO Cellulose - 80% Cust. #: GT-HM-03A No Asbestos Observed Other - 20% Material: Fiberboard Location:

Appearance: brown,fibrous,homogenous Layer: 1 of 1

Lab ID #: 79834 - 07 Asbestos Present: NO Cellulose - 80% Cust. #: GT-HM-03B No Asbestos Observed Other - 20% Material: Fiberboard Location:

Appearance: brown,fibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 3 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 08 Asbestos Present: NO Cellulose - 40%

Cust. #: GT-HM-04A No Asbestos Observed Other - 60% Material: Beige 9x9 VFT Location:

Appearance: beige,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 79834 - 09 Asbestos Present: NO Cellulose - 40% Cust. #: GT-HM-04B No Asbestos Observed Other - 60% Material: Beige 9x9 VFT Location:

Appearance: beige,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 79834 - 10 Asbestos Present: NO Cellulose - 10% Cust. #: GT-HM-05A No Asbestos Observed Fiberglass - 10% Material: Blue Linoleum Other - 80% Location:

Appearance: beige,fibrous,nonhomogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 4 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 11 Asbestos Present: NO Cellulose - 10%

Cust. #: GT-HM-05B No Asbestos Observed Fiberglass - 10% Material: Blue Linoleum Other - 80% Location:

Appearance: beige,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 79834 - 12 Asbestos Present: NO Other - 100% Cust. #: GT-HM-06A No Asbestos Observed Material: Beige 12x12 VFT Location:

Appearance: brown,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 79834 - 12a Asbestos Present: NO Other - 100% Cust. #: GT-HM-06A No Asbestos Observed Material: Glue Location:

Appearance: yellow,nonfibrous,homogenous Layer: 2 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 5 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 13 Asbestos Present: NO Other - 100%

Cust. #: GT-HM-06B No Asbestos Observed Material: Beige 12x12 VFT Location:

Appearance: brown,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 79834 - 13a Asbestos Present: NO Other - 100% Cust. #: GT-HM-06B No Asbestos Observed Material: Glue Location:

Appearance: yellow,nonfibrous,homogenous Layer: 2 of 2

Lab ID #: 79834 - 14 Asbestos Present: NO Cellulose - 80% Cust. #: GT-HM-07A No Asbestos Observed Other - 20% Material: Fiberboard Location:

Appearance: brown,fibrous,nonhomogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 6 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 15 Asbestos Present: NO Cellulose - 80%

Cust. #: GT-HM-07B No Asbestos Observed Other - 20% Material: Fiberboard Location:

Appearance: brown,fibrous,homogenous Layer: 1 of 1

Lab ID #: 79834 - 16 Asbestos Present: NO Cellulose - 20% Cust. #: GT-HM-08A No Asbestos Observed Other - 80% Material: Black Roof Coat Location:

Appearance: black,fibrous,homogenous Layer: 1 of 3

Lab ID #: 79834 - 16a Asbestos Present: NO Cellulose - 5% Cust. #: GT-HM-08A No Asbestos Observed Other - 95% Material: Silver Soft Location:

Appearance: grey,fibrous,homogenous Layer: 2 of 3

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 7 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 16b Asbestos Present: YES Other - 80%

Cust. #: GT-HM-08A Chrysotile - 20% Material: Black Tar Location:

Appearance: black,fibrous,homogenous Layer: 3 of 3

Lab ID #: 79834 - 17 Asbestos Present: NO Cellulose - 20% Cust. #: GT-HM-08B No Asbestos Observed Other - 80% Material: Black Roof Coat Location:

Appearance: black,fibrous,homogenous Layer: 1 of 3

Lab ID #: 79834 - 17a Asbestos Present: NO Cellulose - 2% Cust. #: GT-HM-08B No Asbestos Observed Other - 98% Material: Silver Soft Location:

Appearance: grey,nonfibrous,homogenous Layer: 2 of 3

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 8 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 17b Asbestos Present:

Cust. #: GT-HM-08B Material: Black Tar Location: NOT ANALYZED Appearance:

Layer: 3 of 3

Lab ID #: 79834 - 18 Asbestos Present: NO Other - 100% Cust. #: GT-HM-09A No Asbestos Observed Material: White 12x12 VFT Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 79834 - 18a Asbestos Present: NO Cellulose - 1% Cust. #: GT-HM-09A No Asbestos Observed Other - 99% Material: Mastic Location:

Appearance: black,nonfibrous,homogenous Layer: 2 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 9 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 19 Asbestos Present: NO Other - 100%

Cust. #: GT-HM-09B No Asbestos Observed Material: White 12x12 VFT Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 79834 - 19a Asbestos Present: NO Cellulose - 1% Cust. #: GT-HM-09B No Asbestos Observed Other - 99% Material: Mastic Location:

Appearance: black,nonfibrous,homogenous Layer: 2 of 2

Lab ID #: 79834 - 20 Asbestos Present: NO Cellulose - 40% Cust. #: GT-HM-10A No Asbestos Observed Other - 60% Material: Grey 9x9 VFT Location:

Appearance: grey,fibrous,nonhomogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification,approval, or endorsement by NVLAP, NIST, or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 10 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 21 Asbestos Present: NO Cellulose - 40%

Cust. #: GT-HM-10B No Asbestos Observed Other - 60% Material: Grey 9x9 VFT Location:

Appearance: grey,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 79834 - 22 Asbestos Present: NO Cellulose - 1% Cust. #: GT-HM-11A No Asbestos Observed Other - 99% Material: Grey Roof Coat Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 79834 - 23 Asbestos Present: NO Cellulose - 1% Cust. #: GT-HM-11B No Asbestos Observed Other - 99% Material: Grey Roof Coat Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification,approval, or endorsement by NVLAP, NIST, or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 11 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 24 Asbestos Present: NO Cellulose - 40%

Cust. #: GT-HM-12A No Asbestos Observed Other - 60% Material: Beige 9x9 VFT Location:

Appearance: beige,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 79834 - 25 Asbestos Present: NO Cellulose - 40% Cust. #: GT-HM-12B No Asbestos Observed Other - 60% Material: Beige 9x9 VFT Location:

Appearance: beige,fibrous,nonhomogenous Layer: 1 of 1

Lab ID #: 79834 - 26 Asbestos Present: YES Other - 75% Cust. #: GT-HM-13A Chrysotile - 25% Material: Transite Panel Location:

Appearance: grey,fibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification,approval, or endorsement by NVLAP, NIST, or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 12 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 27 Asbestos Present: NO Fiberglass - 30%

Cust. #: GT-HM-14A No Asbestos Observed Other - 70% Material: Asphalt Shingle Location:

Appearance: black,fibrous,homogenous Layer: 1 of 2

Lab ID #: 79834 - 27a Asbestos Present: NO Cellulose - 40% Cust. #: GT-HM-14A No Asbestos Observed Other - 60% Material: Grey Shingle Location:

Appearance: black,fibrous,homogenous Layer: 2 of 2

Lab ID #: 79834 - 28 Asbestos Present: NO Fiberglass - 30% Cust. #: GT-HM-14B No Asbestos Observed Other - 70% Material: Asphalt Shingle Location:

Appearance: black,fibrous,homogenous Layer: 1 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification,approval, or endorsement by NVLAP, NIST, or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 13 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 28a Asbestos Present: NO Cellulose - 40%

Cust. #: GT-HM-14B No Asbestos Observed Other - 60% Material: Grey Shingle Location:

Appearance: black,fibrous,homogenous Layer: 2 of 2

Lab ID #: 79834 - 29 Asbestos Present: NO Other - 100% Cust. #: GT-HM-15A No Asbestos Observed Material: Glazing Location:

Appearance: beige,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 79834 - 30 Asbestos Present: NO Other - 100% Cust. #: GT-HM-15B No Asbestos Observed Material: Glazing Location:

Appearance: beige,nonfibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification,approval, or endorsement by NVLAP, NIST, or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 14 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 31 Asbestos Present: NO Cellulose - 20%

Cust. #: GT-HM-08C No Asbestos Observed Other - 80% Material: Black Roof Coat Location:

Appearance: black,fibrous,homogenous Layer: 1 of 2

Lab ID #: 79834 - 31a Asbestos Present: NO Cellulose - 1% Cust. #: GT-HM-08C No Asbestos Observed Other - 99% Material: Grey Soft Location:

Appearance: grey,nonfibrous,homogenous Layer: 2 of 2

Lab ID #: 79834 - 32 Asbestos Present: NO Cellulose - 1% Cust. #: GT-HM-11C No Asbestos Observed Other - 99% Material: Grey Roof Coat Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification,approval, or endorsement by NVLAP, NIST, or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 15 of 16

Report To: ARI Report # 18-79834 Mr. Aaron Paquet Date Collected: 09/20/18 Red Cedar Consulting Date Received: 09/24/18 P.O. Box 13216 Date Analyzed: 09/26/18 Lansing, MI 48901 Date Reported: 09/28/18

Project : Gombos Trailers

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 79834 - 33 Asbestos Present:

Cust. #: GT-HM-13B Material: Transite Panel Location: NOT ANALYZED Appearance:

Layer: of

Lab ID #: Asbestos Present:

Cust. #:

Material:

Location:

Appearance:

Layer: of

Lab ID #: Asbestos Present:

Cust. #:

Material:

Location:

Appearance:

Layer: of

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification,approval, or endorsement by NVLAP, NIST, or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

(734) 449-9990, Fax (734) 449-9991 Page 16 of 16

Attachment B Figure 1 Site Diagram

Figure 1 Site Diagram

Note: Figure created by Red Cedar Consulting Asbestos Sample Locations

Gombos Trailers -Not To Scale- Montmorency County, MI

Tables

Table 1 - Summary of Hazardous Materials, Gombos Trailers Montmorency County, Michigan

Hazardous Materials Description and Location

Location Material Description Quantity

Belmont Trailer Living Room Thermostat 1

Green Trailer Dining Room Thermostat 1

Silver Trailer Quart Container Misc. Oil 6

Silver Trailer 100 lb Propane Cylinder 4

Table 2 - Summary of Sample Descriptions and Asbestos Laboratory Results, Gombos Trailers Montmorency County, Michigan

Sample

Number Sample Description Friable

Material

Type

Material

Classification

% Asbestos

Laboratory

Result

Sample Location Approx. Material

Quantity

GT-HM-01A Black Roof Coat No M Category I ND Belmont Trailer Roof NA

GT-HM-01B Black Roof Coat No M Category I ND Belmont Trailer Roof NA

GT-HM-01C Black Roof Coat No M Category I ND Belmont Trailer Roof NA

GT-HM-02A Asphalt Shingle No M Category I ND/ND Belmont Trailer

Addition Roof

NA

GT-HM-02B Asphalt Shingle No M Category I ND/ND Belmont Trailer

Addition Roof

NA

GT-HM-03A Fiberboard Yes M Category II ND Belmont Trailer

Underbelly

NA

GT-HM-03B Fiberboard Yes M Category II ND Belmont Trailer

Underbelly

NA

GT-HM-04A Beige 9x9 VFT No M Category I ND Belmont Trailer Living

Room

NA

GT-HM-04B Beige 9x9 VFT No M Category I ND Belmont Trailer

Bathroom

NA

GT-HM-05A Blue Linoleum No M Category I ND Belmont Trailer

Cupboards

NA

GT-HM-05B Blue Linoleum No M Category I ND Belmont Trailer Closet NA

GT-HM-06A Beige 12x12 Vinyl Floor Tile No M Category I ND/ND Belmont Trailer

Kitchen

NA

GT-HM-06B Beige 12x12 Vinyl Floor Tile No M Category I ND/ND Belmont Trailer

Kitchen

NA

GT-HM-07A Fiberboard Yes M Category II ND Belmont Trailer

Kitchen Ceiling

NA

GT-HM-07B Fiberboard Yes M Category II ND Belmont Trailer N

Bedroom Ceiling

NA

GT-HM-08A Black Roof Coat No M Category I

ND/ND/

20% CH

Green Trailer Roof 320 sq. ft.

GT-HM-08B Black Roof Coat No M Category I ND/ND/NA Green Trailer Roof NA

GT-HM-09A White 12x12 VFT No M Category I ND/ND Green Trailer Kitchen NA

GT-HM-09B White 12x12 VFT No M Category I ND/ND Green Trailer Kitchen NA

GT-HM-10A Gray 9x9 VFT No M Category I ND Green Trailer Center

Bedroom

NA

GT-HM-10B Gray…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .