FPI_Specification_Sheet.pdf
PDF 1 MB Posted
- Solicitation number
- SS- 24 - 206
- Issued by
- Pinellas County, Florida
About this file
The document is a detailed specification sheet for the McCrometer FPI Mag Flow Meter with Converter, specifically targeting municipal water, wastewater, and industrial facility applications. The FPI Mag is a full profile insertion electromagnetic flow meter designed for pipe sizes ranging from 4 to 72 inches, with custom options available up to 138 inches. The product offers hot tap installation without service interruption, making it ideal for retrofits, upgrades, and maintenance projects across various sectors including campus facilities, hospitals, airports, power plants, paper mills, chemical plants, and food & beverage industries.
The specification sheet provides comprehensive technical details including accuracy (±0.5% of measured value), flow measurement methods, material specifications, temperature ranges, and multiple configuration options. Pricing varies based on pipe size, with examples ranging from $3,774 to $45,111. The meter comes with multiple power options (AC, DC, battery), output configurations (analog, digital, smart protocols), and certification standards including ISO 9001:2015, UL, and NSF/ANSI. Additional features include a multi-electrode sensor for full pipe profile measurement, no moving parts, NIST traceable calibration, and a 2-year warranty. The product supports various engineering units and includes a data logger with five years of storage capacity.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specification Sheet FPI Mag Flow Meter with Converter
30121-75 Rev. 2.7 | 18JAN2024
MUNICIPAL WATER AND
WASTEWATER
The FPI Mag is ideal for chilled water in campus style facilities, hospitals, airports, hotels, casinos, etc.
The FPI Mag is also suitable for a variety of industrial facilities: power plants (including cogeneration), paper mills, chemical & petrochemical plants, metals & mining, and food & beverage.
• Distribution
• Effluent
• Filter balancing and backwash
Wastewater
• Cooling water
• Fire water
• Feed water
• Raw water
• Inlet to surge basin
• Effluent wastewater
Benefits:
• Hot Tap Installation - No service interruption
• Accurate – Measures the full flow profile
• Lower Cost – Installed savings more than 45%
• Robust – No moving parts to wear or break
• Versatile – Great for plant maintenance, upgrades and retrofits
• Accessible – Insertion design provides easy access
• Virtually No Maintenance – No field calibration required
FPI Mag® Sensor ProComm® Converter
ProComm® GO Converter
The FPI Mag® (Full Profile Insertion) electromagnetic flow meter is the only hot tap full profile insertion flow meter available on the market. The FPI Mag installs without service interruption making it ideal for retrofits, upgrades and maintenance projects and sites never metered before. The hot tap installation significantly reduces installation time eliminating the need to de-water lines or cut pipe.
The multi-electrode sensor delivers an accurate measurement of the full pipe profile rivaling the performance of a full-bore mag meter. The repeatable, stable measurement across the entire flow profile compensates for variable flow profiles, including swirl and turbulent conditions.
The FPI Mag is the industry’s most economical flow metering solution offering unbeatable value in the cost of installation and ownership reducing installed costs by more than 45 percent in medium and large line sizes. The compact insertion design fits in confined spaces and offers complete accessibility. The flow meter can be removed in pipes under pressure for easy inspection, cleaning, calibrating, or verification. Installation costs are reduced by eliminating the need for heavy equipment and extensive manpower.
The innovative flow meter comes pre-calibrated from McCrometer’s NIST traceable calibration labs and requires no recalibration in the field. With no moving parts and a single-piece design, the FPI Mag’s sensor contains nothing to wear or break and is generally immune to clogging by sand, grit, or other debris.
The electrodes are encased in a heavy-duty 316 stainless steel sensor body for maximum structural integrity and coated with a NSF certified 3M™ fusion-bonded epoxy coating for operational longevity.
The FPI Mag Full Profile Insertion mag meter supports the following water and wastewater treatment applications:
Water
• Pumping stations
• UV dosing
• Wells and booster stations
• Effluent • Recycle / reclaim
INDUSTRIAL FACILITIES
Applications Include
30121-75 Rev. 2.7 | 18JAN2024Page 2
PART NUMBER MATRIX FOR FPI MAG WITH PROCOMM CONVERTER
Continued on next page
39 _ _ _ - _ _ _ ____ _ - __ - _ Single or Bidirectional Flow
Bidirectional Flow 4 Single Forward Flow 5 Meter Type (Calculated) Standard Length Sensor S
Custom Length Sensor C Nominal Line Size 394S 394C 395S 395C
4 in 04 $4,245 $4,670 $3,774 $4,150 6 in 06 $4,245 $4,670 $3,892 $4,281 8 in 08 $4,600 $5,060 $4,128 $4,540
10 in 10 $5,425 $5,967 $4,835 $5,319 12 in 12 $6,604 $7,265 $5,897 $6,486 14 in 14 $7,548 $8,303 $6,722 $7,394 16 in 16 $9,022 $9,924 $8,020 $8,823 18 in 18 $10,650 $11,715 $9,141 $10,055 20 in 20 $13,047 $14,352 $11,735 $12,909 24 in 24 $14,299 $15,729 $12,826 $14,109
30 in 30 Not
Offered $21,008 Not Offered $19,902
36 in 36 Not
Offered $23,809 Not Offered $22,556
42 in 42 Not
Offered $27,777 Not Offered $26,314
48 in 48 Not
Offered $30,074 Not Offered $28,403
54 in 54 Not
Offered $33,833 Not Offered $31,953
60 in 60 Not
Offered $37,593 Not Offered $35,504
66 in 66 Not
Offered $41,351 Not Offered $39,054
72 in 72 Not
Offered $45,111 Not Offered $42,605
78 in 78 Not
Offered Contact Factory
Not Offered Contact Factory
84 in 84 Not
Offered Contact Factory
Not Offered Contact Factory
90 in 90 Not
Offered Contact Factory
Not Offered Contact Factory
96 in 96 Not
Offered Contact Factory
Not Offered Contact Factory
100 in H0 Not
Offered Contact Factory
Not Offered Contact Factory
110 in H1 Not
Offered Contact Factory
Not Offered Contact Factory
120 in H2 Not
Offered Contact Factory
Not Offered Contact Factory
130 in H3 Not
Offered Contact Factory
Not Offered Contact Factory
#Confidential - Company Proprietary
30121-75 Rev. 2.7 | 18JAN2024Page 3
PART NUMBER MATRIX FOR FPI MAG WITH PROCOMM CONVERTER (CONT.)
39 _ _ _ - _ _ _ ____ _ - __ - _ Sensor Length Options (From Calc Sheet)
20" Sensor Length 020 21" Sensor Length 021 22" Sensor Length 022
Each nominal Inch Length … Calc 175" Sensor Length ##
Electrode Material Options S316 Stainless Steel (Standard) S $0
Hastelloy H $384 Ball Valve Options
2" NPT N $0
2" BSPT B $0
No Valve 2" NPT X $0 No Valve 2" BSPT Y $0
Remote Mount Cable Connector Options Quick Connect (Standard) Q $0
Strain Relief R $0 Remote Cable Length Options Non Standard Length Cable
25 feet (Standard) 025 $0 Strain Relief Quick Connect
50 feet 050 $119 $4.70 per ft $7.15 per ft
75 feet 075 $238 100 feet 100 $357 125 feet 125 $477 150 feet 150 $595 175 feet 175 $714 200 feet 200 $834 500 feet 500 $2,263
Converter Power Options A/C Power A $0 DC Power D $153
Converter Output Options Dual 4-20mA Analog, Dual Digital (Standard) 1 $0
Modbus + STD (Two 4-20, two Dig) 2 $636 Hart + STD (Two 4-20, two Dig) 3 $636
Datalogger + STD (Two 4-20, two Dig) 4 $595 Datalogger + Modbus + STD (Two 4-20, two Dig) 5 $1,232
Datalogger + Hart + STD (Two 4-20, two Dig) 6 $1,232 AMI Smart Output + STD (Two 4-20, two Dig) 7* $342
Datalogger + AMI Smart Output + STD (Two 4-20, two Dig) 8* $938 Smart Output Protocol Options (*7 or 8 output option required)
No AMI Outputs - $0 Sensus Protocol (6ft cable, Nicor Connector hardwired only) SEN $0
Itron 6 digit Protocol (6ft cable, Nicor Connector hardwired only) IT6 $0 Itron 9 digit [100W] Protocol (6ft cable, Nicor Connector hardwired only) IT9 $0
Neptune Protocol (6ft cable, Nicor Connector hardwired only) NEP $0 Battery Power/ ATT wireless Telemetry System (RTU, Solar Panel, 7 Pin Cable) ATT $2,680
Battery Power/ Verizon wireless Telemetry System (RTU, Solar Panel, 7 Pin Cable) VZW $2,726 Hazardous Area Location
Class 1, Division 2, Groups A-D, T5 HL $123
Above 28" it is $29 per
30121-75 Rev. 2.7 | 18JAN2024Page 4
PART NUMBER MATRIX FOR FPI MAG WITH PROCOMM GO CONVERTER
39 _ _ _ - _ _ _ _ _ _ _ _ _ - _ - _ Single or Bidirectional Flow
Bidirectional Flow 4 Single Forward Flow 5
Meter Type Standard Length Sensor S
Custom Length Sensor C Nominal Line Size 394S 394C 395S 395C
4 in 04 $4,245 $4,670 $3,774 $4,150
6 in 06 $4,245 $4,670 $3,892 $4,281
8 in 08 $4,600 $5,060 $4,128 $4,540
10 in 10 $5,425 $5,967 $4,835 $5,319
12 in 12 $6,604 $7,265 $5,897 $6,486
14 in 14 $7,548 $8,303 $6,722 $7,394
16 in 16 $9,022 $9,924 $8,020 $8,823
18 in 18 $10,650 $11,715 $9,141 $10,055
20 in 20 $13,047 $14,352 $11,735 $12,909
24 in 24 $14,299 $15,729 $12,826 $14,109
30 in 30 Not Offered $21,008 Not Offered $19,902
36 in 36 Not Offered $23,809 Not Offered $22,556
42 in 42 Not Offered $27,777 Not Offered $26,314
48 in 48 Not Offered $30,074 Not Offered $28,403
54 in 54 Not Offered $33,833 Not Offered $31,953
60 in 60 Not Offered $37,593 Not Offered $35,504
66 in 66 Not Offered $41,351 Not Offered $39,054
72 in 72 Not Offered $45,111 Not Offered $42,605
78 in 78 Not Offered Contact Factory Not Offered Contact Factory 84 in 84 Not Offered Contact Factory Not Offered Contact Factory 90 in 90 Not Offered Contact Factory Not Offered Contact Factory 96 in 96 Not Offered Contact Factory Not Offered Contact Factory
100 in H0 Not Offered Contact Factory Not Offered Contact Factory 110 in H1 Not Offered Contact Factory Not Offered Contact Factory 120 in H2 Not Offered Contact Factory Not Offered Contact Factory 130 in H3 Not Offered Contact Factory Not Offered Contact Factory
Sensor Length Options 20" Sensor Length 020 21" Sensor Length 021
22" Sensor Length 022 Calc Above 28" it is $29 per additional inch
Each nominal Inch Length … 175" Sensor Length ###
Electrode Material Options S316 Stainless Steel (Standard) S $0
Hastelloy H $384
Continued on next page
30121-75 Rev. 2.7 | 18JAN2024Page 5
PART NUMBER MATRIX FOR FPI MAG WITH PROCOMM GO CONVERTER (CONT.)
39 _ _ _ - _ _ _ _ _ _ _ _ _ - _ - _ Ball Valve Options
2" NPT N $0
2" BSPT B $0
No Valve 2" NPT X $0 No Valve 2" BSPT Y $0
Remote Mount Cable Connector Options 25 ft Quick Connect (Standard) Q $0
25 ft Strain Relief R $0
Converter Power Options Battery Power (Standard) B $0
Solar Power, Battery Backup S $837 A/C Power, Battery Backup E $788 DC Power, Battery Backup F $289
Converter Output Options No Outputs (Standard) - $0
No Outputs, DC Cable Only 0 $0 Two Digital Out 1 $79
4-20mA Analog only 2 $158 4-20mA Analog + Two Dig Out 3 $236
AMI Smart Output only 4 $551 AMI Smart Output + Two Dig Out 5 $630
AMI Smart Output + 4-20mA Analog 6 $709 AMI Smart Output + 4-20mA Analog + Two Dig Out 7 $788
DC Power/ Analog Out Cable Options No DC Power or Outputs (Standard) - $0
No Cable - Output Configured (Quick Conn) 0 $0 6 ft (Open Leads) 1 $32
25 ft (Open Leads) 2 $56 50 ft (Open Leads) 3 $113
Pulse Cable Length Options No Outputs (Standard) - $0
No Cable - Output Configured (Quick Conn) 0 $0 6 ft (Open Leads) 1 $41
25 ft (Open Leads) 2 $64 50 ft (Open Leads) 3 $125
25 ft (7-Pin Male connector for Telemetry) 4 $150 50 ft (7-Pin Male connector for Telemetry) 5 $244
Output Cable Terminal Options Strain Relief (Standard) 1 $0
Quick Connect Cable Terminals (25 & 50 ft only) 2 $188 Smart Output Protocol Options (*7 or 8 output option required)
No AMI Outputs - $0 Sensus Protocol (6ft cable, Nicor Connector hardwired only) SEN $0
Itron 6 digit Protocol (6ft cable, Nicor Connector hardwired only) IT6 $0 Itron 9 digit [100W] Protocol (6ft cable, Nicor Connector hardwired only) IT9 $0
Neptune Protocol (6ft cable, Nicor Connector hardwired only) NEP $0 Battery Power/ ATT wireless Telemetry System (RTU, Solar Panel, 7 Pin Cable) ATT $2,680
Battery Power/ Verizon wireless Telemetry System (RTU, Solar Panel, 7 Pin Cable) VZW $2,726 Hazardous Area Location
Class 1, Division 2, Groups A-D, T5 HL $123
30121-75 Rev. 2.7 | 18JAN2024Page 6
FLOW METER SPECIFICATIONS
The full pipe averaging flow meter comes complete with Mounting Hardware, AC Converter with Dual 4-20mA output, 25 Feet of Dual Submersible Cables with quick connects at sensor, Stainless Steel Body, 316 Stainless Steel Electrodes, NSF Approved Fusion Bonded Epoxy Coating, 2” Stainless Steel Ball Valve (minimum of 1-7/8” port I.D.), 2” x Close Stainless Steel Nipple, 2-Year Warranty.
Measurement Volumetric flow in filled flow conduits 4” (100 mm) to 138” (3,500 mm) utilizing insertable electromagnetic averaging sensor. Flow indication in English Standard or Metric units.
Flow Measurement Method Electromagnetic
Calibrated accuracy for forward and bidirectional sensors
• AC or DC power: ±0.5% of measured value ±0.006 ft/s (±0.0018 m/s)
• Battery power: ±1% of measured value ±0.006 ft/s (±0.0018 m/s)
• Reverse Flow: ±1% of measured value ±0.006 ft/s (±0.0018 m/s) Note: See section “Flow Meter Pipe Sizes and Flow Ranges with ProComm Converter” for a table of velocities by pipe size.
Linearity 0.3% of Range
Repeatability 0.2% of Reading
Direction measurement
• 395 sensor - Forward flow measurement and reverse flow indication
• 394 sensor - bidirectional flow measurement
Materials Coating Fusion bonded epoxy (NSF 61 approved) coated 316 stainless steel
Insertion hardware 316 Stainless Steel
Compression seal Silicone Rubber
Sensor electrodes 316 Stainless Steel
Temperature Range Operation -10 to 60°C (14 to 140°F) up to 250 PSI
Storage -15 to 60°C (5 to 140° F)
Note regarding storage: During freezing conditions and when meter is not in use, sensor must be removed from pipe and stored in dry conditions.
Note: Damage to the sensor caused by allowing the sensor freeze in the pipe is not covered by the warranty.
Sensor Cable Lengths Standard 25’/7.6 m McCrometer supplied submersible cable with each remote mount unit.
Optional Up to 500’/152.4 m, or 25’/7.6 m max for battery powered.
Quick Connect Available in standard cable lengths:
Feet: 25, 50, 75, 100, 125, 150, 175, 200, 500 Meters: 7.6, 15.25. 22.5, 30.5, 38.1, 45.75, 53.3, 61, 152.4 Custom cable lengths at additional cost.
Electrical Connections
• Quick Connect
• Compression gland seals
30121-75 Rev. 2.7 | 18JAN2024Page 7
IP Rating Standard model • Quick Connect (IP68)
• Compression gland seals (IP68)
HL model • Quick Connect (IP67)
• Compression gland seals (IP67)
Sensor Submersibility Depth With standard quick connect 1.8 m (6 ft.)
With optional strain relief cable 9 m (30 ft.)
Certifications and Approvals Standard Model • ISO 9001:2015 certified quality management system
• Certified by MET to UL 61010-1 / CSA C22.2 No. 61010-1
• Certified to NSF / ANSI Standards*
COMPONENT
NSF/ANSI/CAN 61
NSF/ANSI 372
I A P M O R & T
HL Model • ISO 9001:2015 certified quality management system
• Certified by MET: Safety: UL61010-1 / CSA C22.2 No. 61010-1, Third Edition: Safety of Electrical Equipment For Measurement, Control, and Laboratory Use
• Certified by MET: Standards: ANSI / ISA12.12.01 / CSA C22.2 No. 213, Nonincendive Electrical Equipment
• Class I and II, Division 2
• Class III, Divisions 1 and 2 Hazardous (Classified) Locations
• Certified to NSF / ANSI Standards*
* Certified by IAPMO R&T to NSF/ANSI 61 for material safety and NSF/ANSI 372 for low lead content.
System Options
• Hastelloy® electrodes
• Additional sensor cable up to 475’ (500’ max for model 395 and 200’ max for model 394)
• Extension to hardware clearance
• Annual verification / calibration
• Sensor insertion tool
• Stainless steel ID tag
Note regarding cable length: McCrometer recommends minimizing cable length. Electromagnetic flow meters may have unfavorable signal strength to noise ratio in electrically noisy environments. Longer lengths of cable increase the likelihood of interference. In those cases where the meter’s signal must be transmitted a long distance, or where the environment may be particularly noisy, we suggest using the converter’s analog output(s). That allows locating the converter as close as possible to the metering location.
30121-75 Rev. 2.7 | 18JAN2024Page 8
FLOW METER PIPE SIZES AND FLOW RANGES WITH PROCOMM CONVERTER
IMPERIAL UNITS
Pipe Size (Nominal)
Pipe ID Range Flow Ranges (GPM Standard)
Standard Program Defaults1
Minimum Clearance
Required During Installation2
Velocity Range3
(f/s)Min Pipe
ID
Max Pipe ID
Min
(GPM)1
Max
(GPM)1
20mA
(GPM)
S = Standard (Available in 395 models Pipe Sizes 4” - 24” as shown in table below) C = Custom (Available in all 394 and 395 models Pipe Sizes 4” - 138”) Standard Length Hardware and Installation Clearance Dimensions are based on a 4” Maximum Height Coupling and Pipe Schedule Standard
4" 3.74 4.99 12 1280 1280 51" 0.3 - 32 6" 5.00 7.24 26 2800 2800 51" 0.3 - 32 8" 7.25 9.24 47 5000 5000 55" 0.3 - 32
10" 9.25 11.24 80 8000 8000 55" 0.3 - 32 12" 11.25 12.99 110 11000 11000 59" 0.3 - 32 14" 13.00 14.99 150 15000 15000 59" 0.3 - 32 16" 15.00 16.75 190 20000 20000 59" 0.3 - 32 18" 16.76 18.80 240 26000 26000 63" 0.3 - 32 20" 18.81 22.74 300 28000 28000 63" 0.3 - 28 24" 22.75 24.99 410 33000 33000 67" 0.3 - 23 30" 25.00 33.99 600 44000 44000 71.25" 0.3 - 20 36" 34.00 39.99 1000 48000 48000 77.25" 0.3 - 15 42" 40.00 45.99 1300 56000 56000 83.25" 0.3 - 13 48" 46.00 51.99 1700 62000 62000 89.25" 0.3 - 11 54” 52.00 57.99 2200 79000 79000 95.25” 0.3 - 11 60" 58.00 63.99 2600 97000 97000 101.25" 0.3 - 11 66” 64.00 69.99 3200 106000 106000 107.25” 0.3 - 10 72" 70.00 75.99 3800 127000 127000 113.25" 0.3 - 10
78”-128” 76.00 138.00 Available - Call Factory at 1-800-220-2279
! Required Information
At the time of ordering, please be prepared to provide the following information:
1. Pipe ID and Pipe OD
2. Unit of Measure (US Gallons is Default)
3. Maximum pressure
4. FPI Specification Data Sheet for custom length sensors
Consult factory if any chemicals are in use.
1 Default totalizer units measured as KGAL.
2 Hardware clearance after installation for all sizes is 28”.
3 Flow temperature range -10° to 60° C (14° to 140° F) up to 250 PSI, max pressure is 250 psi.
30121-75 Rev. 2.7 | 18JAN2024Page 9
Pipe Size (Nominal)
(mm)
Pipe ID Range Flow Ranges (m3/h standard)
Standard Program Defaults1
Minimum Clearance Required
During Installation
(cm)2
Velocity Range3
(m/s) Min
Pipe ID (mm)
Max Pipe ID
(mm)
Min (m3/h)1
Max (m3/h)1 20mA
S = Standard (Available in 395 models pipe sizes 100 mm - 600 mm as shown in table below) C = Custom (Available in all 394 and 395 models pipe sizes 100 mm - 3,500 mm) Standard length hardware and installation clearance dimensions are based on a 100 mm maximum height coupling and pipe schedule standard
DN100 95 127 3 290 135 129.5 0.1 - 10
DN150 127 184 6 635 295 129.5 0.1 - 10
DN200 184 235 11 1135 535 139.7 0.1 - 10
DN250 235 285 18 1815 900 139.7 0.1 - 10
DN300 286 330 25 2500 1250 149.9 0.1 - 10
DN350 330 381 35 3400 1700 149.9 0.1 - 10
DN400 381 425 45 4550 2150 149.9 0.1 - 10
DN450 426 478 55 5900 2700 160.0 0.1 - 10
DN500 478 578 70 6350 3400 160.0 0.1 - 8.5
DN600 578 635 95 7500 4650 170.2 0.1 - 7
DN750 635 863 135 10000 6800 181.0 0.1 - 6
DN900 864 1016 230 10900 8200 196.2 0.1 - 4.5
DN1050 1016 1168 295 12700 10200 211.5 0.1 - 4
DN1200 1168 1321 385 14000 12500 226.7 0.1 - 3.5
DN1350 1321 1473 500 18000 14750 241.9 0.1 - 3.5
DN1500 1473 1625 590 22000 18000 257.2 0.1 - 3.5
DN1650 1626 1778 725 24000 20500 272.4 0.1 - 3
DN1800 1778 1930 865 29000 22500 287.7 0.1 - 3
DN2000
and up 1931 3505 Available - Call Factory at 1-800-220-2279
1 Default totalizer units measured as m3.
2 Hardware clearance after installation for all sizes is 700 mm.
3 Flow temperature range -10° to 60° C (14° to 140° F) up to 17 bar, max pressure is 17 bar.
FLOW METER PIPE SIZES AND FLOW RANGES WITH PROCOMM CONVERTER
METRIC UNITS
Required Information
At the time of ordering, please be prepared to provide the following information:
1. Pipe ID and pipe OD
2. Unit of measure (m3 is default)
3. Maximum pressure
4. FPI specification data sheet for custom length sensors
Consult factory if any chemicals are in use.
30121-75 Rev. 2.7 | 18JAN2024Page 10
FLOW METER PIPE SIZES AND FLOW RANGES WITH PROCOMM GO CONVERTER
IMPERIAL UNITS
Pipe Size (Nominal)
Pipe ID Range Flow Ranges (GPM Standard)
Standard Program Defaults1
Minimum Clearance
Required During Installation2
Velocity Range3
(f/s)Min Pipe
ID
Max Pipe ID
Min
(GPM)1
Max
(GPM)1
20mA
(GPM)
S = Standard (Available in 395 models Pipe Sizes 4” - 24” as shown in table below) C = Custom (Available in all 394 and 395 models Pipe Sizes 4” - 138”) Standard Length Hardware and Installation Clearance Dimensions are based on a 4” Maximum Height Coupling and Pipe Schedule Standard
4" 3.74 4.99 20 1280 1280 51" 0.5 - 32 6" 5.00 7.24 43 2800 2800 51" 0.5 - 32 8" 7.25 9.24 78 5000 5000 55" 0.5 - 32
10" 9.25 11.24 130 8000 8000 55" 0.5 - 32 12" 11.25 12.99 180 11000 11000 59" 0.5 - 32 14" 13.00 14.99 250 15000 15000 59" 0.5 - 32 16" 15.00 16.75 320 20000 20000 59" 0.5 - 32 18" 16.76 18.80 400 26000 26000 63" 0.5 - 32 20" 18.81 22.74 500 28000 28000 63" 0.5 - 28 24" 22.75 24.99 680 33000 33000 67" 0.5 - 23 30" 25.00 33.99 1000 44000 44000 71.25" 0.5 - 20 36" 34.00 39.99 1700 48000 48000 77.25" 0.5 - 15 42" 40.00 45.99 2200 56000 56000 83.25" 0.5 - 13 48" 46.00 51.99 2800 62000 62000 89.25" 0.5 - 11 54” 52.00 57.99 3700 79000 79000 95.25” 0.5 - 11 60" 58.00 63.99 4300 97000 97000 101.25" 0.5 - 11 66” 64.00 69.99 5300 106000 106000 107.25” 0.5 - 10 72" 70.00 75.99 6300 127000 127000 113.25" 0.5 - 10
78”-128” 76.00 138.00 Available - Call Factory at 1-800-220-2279
! Required Information
At the time of ordering, please be prepared to provide the following information:
1. Pipe ID and Pipe OD
2. Unit of Measure (US Gallons is Default)
3. Maximum pressure
4. FPI Specification Data Sheet for custom length sensors
Consult factory if any chemicals are in use.
1 Default totalizer units measured as KGAL.
2 Hardware clearance after installation for all sizes is 28”.
3 Flow temperature range -10° to 60° C (14° to 140° F) up to 250 PSI, max pressure is 250 psi.
30121-75 Rev. 2.7 | 18JAN2024Page 11
FLOW METER PIPE SIZES AND FLOW RANGES WITH PROCOMM GO CONVERTER
METRIC UNITS
Pipe Size (Nominal)
(mm)
Pipe ID Range Flow Ranges (m3/h standard)
Standard Program Defaults1
Minimum Clearance Required
During Installation
(cm)2
Velocity Range3
(m/s) Min
Pipe ID (mm)
Max Pipe ID
(mm)
Min (m3/h)1
Max (m3/h)1 20mA
S = Standard (Available in 395 models pipe sizes 100 mm - 600 mm as shown in table below) C = Custom (Available in all 394 and 395 models pipe sizes 100 mm - 3,500 mm) Standard length hardware and installation clearance dimensions are based on a 100 mm maximum height coupling and pipe schedule standard
DN100 95 127 5 290 135 129.5 0.15 - 10
DN150 127 184 10 635 295 129.5 0.15 - 10
DN200 184 235 18 1135 535 139.7 0.15 - 10
DN250 235 285 30 1815 900 139.7 0.15 - 10
DN300 286 330 41 2500 1250 149.9 0.15 - 10
DN350 330 381 57 3400 1700 149.9 0.15 - 10
DN400 381 425 73 4550 2150 149.9 0.15 - 10
DN450 426 478 91 5900 2700 160.0 0.15 - 10
DN500 478 578 114 6350 3400 160.0 0.15 - 8.5
DN600 578 635 154 7500 4650 170.2 0.15 - 7
DN750 635 863 227 10000 6800 181.0 0.15 - 6
DN900 864 1016 386 10900 8200 196.2 0.15 - 4.5
DN1050 1016 1168 500 12700 10200 211.5 0.15 - 4
DN1200 1168 1321 636 14000 12500 226.7 0.15 - 3.5
DN1350 1321 1473 840 18000 14750 241.9 0.15 - 3.5
DN1500 1473 1625 977 22000 18000 257.2 0.15 - 3.5
DN1650 1626 1778 1204 24000 20500 272.4 0.15 - 3
DN1800 1778 1930 1431 29000 22500 287.7 0.15 - 3
DN2000
and up 1931 3505 Available - Call Factory at 1-800-220-2279
1 Default totalizer units measured as m3.
2 Hardware clearance after installation for all sizes is 700 mm.
3 Flow temperature range -10° to 60° C (14° to 140° F) up to 17 bar, max pressure is 17 bar.
Required Information
At the time of ordering, please be prepared to provide the following information:
1. Pipe ID and pipe OD
2. Unit of measure (m3 is default)
3. Maximum pressure
4. FPI specification data sheet for custom length sensors
Consult factory if any chemicals are in use.
30121-75 Rev. 2.7 | 18JAN2024Page 12
PROCOMM CONVERTER PART NUMBER MATRIX
R $1,780 M $1,780
A $0 D $153
1 $0 2 $636 3 $636 4 $595 5 $1,232 6 $1,232
7* $342 8* $938
- $0
SEN $0
IT6 $0
IT9 $0
NEP $0
ATT $2,680
VZW $2,726
HL $123
Hart + STD (Two 4-20, two Dig) Datalogger/BIV + STD (Two 4-20, two Dig)
Datalogger/BIV + Hart + STD (Two 4-20, two Dig)
Smart Output Protocol Options (*7 or 8 output option required) No AMI Outputs
AMI Smart Output + STD (Two 4-20, two Dig) Datalogger/BIV + AMI Smart Output + STD (Two 4-20, two Dig)
Neptune Protocol (6ft cable, Nicor Connector hardwired only) ATT Wireless Telemetry System (RTU, Solar Panel, 15 ft 7 pin Cable)
Sensus Protocol (6ft cable, Nicor Connector hardwired only) Itron 6 digit Protocol (6ft cable, Nicor Connector hardwired only)
PC
Modbus + STD (Two 4-20, two Dig)
Converter Power Options
Converter Mounting Options
Dual 4-20mA Analog, Dual Digital (Standard) Converter Output Options
Remote Mount Meter Mount
A/C Power DC Power
Datalogger/BIV + Modbus + STD (Two 4-20, two Dig)
Class 1, Division 2, Groups A-D, T5 Hazardous Area Location
Verizon Wireless Telemetry System (RTU, Solar Panel, 15 ft 7 pin Cable)
Itron 9 digit [100W] Protocol (6ft cable, Nicor Connector hardwired only)
30121-75 Rev. 2.7 | 18JAN2024Page 13
PROCOMM GO CONVERTER PART NUMBER MATRIX
M $924 R $1,712
B $0 S $837 E $788 F $289
- $0 0 $0 1 $79 2 $158 3 $236 4 $551 5 $630 6 $709 7 $788
- $0 0 $0 1 $32 2 $56 3 $113
- $0 0 $0 1 $41 2 $64 3 $125 4 $150 5 $244
1 $0 2 $188
- $0
SEN $0
IT6 $0
IT9 $0
NEP $0
ATT $2,680
VZW $2,726
HL $123
Converter Mounting Options Meter Mount Converter (Standard)
Remote Mount
PG
AMI Smart Output + 4-20mA Analog + Two Dig Out
Converter Power Options Battery Power (Standard)
A/C Power, Battery Backup DC Power, Battery Backup
Solar Power, Battery Backup
Converter Output Options
AMI Smart Output + 4-20mA Analog
AMI Smart Output Only
No Outputs (Standard)
4-20mA Analog only 4-20mA Analog + Two Dig Out
AMI Smart Output + Two Dig Out
No Outputs, DC Cable Only Two Digital Out
DC Power/ Analog Out Cable Options No DC Power or Outputs (Standard)
No Cable - Output Configured (Quick Conn) 6 ft (Open Leads - Strain Relief)
25 ft (Open Leads) 50 ft (Open Leads)
Pulse Cable Length Options No Outputs (Standard)
Sensus Protocol (6ft cable, Nicor Connector hardwired only)
No Cable - Output Configured (Strain Relief or Quick Conn) 6 ft (Open Leads)
25 ft (Open Leads) 50 ft (Open Leads)
25 ft (7-Pin Male connector for Telemetry) 50 ft (7-Pin Male connector for Telemetry)
Output Cable Terminal Options Strain Relief (Standard)
Quick Connect (25 & 50 ft Cable length only) Smart Output Protocol Options (*4 - 7 output option required)
No AMI Outputs
Itron 6 digit Protocol (6ft cable, Nicor Connector hardwired only) Itron 9 digit [100W] Protocol (6ft cable, Nicor Connector hardwired only)
ATT Wireless Telemetry System (RTU, Solar Panel, 15 ft 7 pin Cable) Verizon Wireless Telemetry System (RTU, Solar Panel, 15 ft 7 pin Cable)
Hazardous Area Location Class 1, Division 2, Groups A-D, T5
Neptune Protocol (6ft cable, Nicor Connector hardwired only)
30121-75 Rev. 2.7 | 18JAN2024Page 14
PROCOMM CONVERTER SPECIFICATIONS9.0 SPECIFICATIONS
30124-60 Rev. 1.7 | 26OCT2022Page 42
SPECIFICATIONS
Physical Speci� cations Electronic Housing Diecast aluminum, powder coated enclosure w/ tamper resistant seal
Converter Dimensions
Remote Mount: Height: 7.3” (18.5 cm) Width: 8.5” (21.6 cm) Depth: 4.3” (10.9 cm) Meter Mount: Height: 6.9” (17.5 cm) Width: 7.2” (18.25 cm) Depth: 6.2” (15.7 cm)
Power AC Power: 100-240 VAC / 45-66 Hz (10 W) Note: AC or DC must be speci� ed at time of ordering.DC Power: 12-48 VDC (10 W)
Connection Options • Compression gland seals for 0.24” to 0.47” diameter round cable
• Conduit option: 1/2” NPT threaded connections
Galvanic Isolation All inputs / outputs are galvanically isolated from power supply up to 500 V
Conductivity Minimum conductivity of 5µS/cm
Performance and Operational Speci� cations
Accuracy • ±0.5% from 1 f/s to max velocity, up to ±1% for 0.3 to 1 f/s
• ±1% for reverse � ow
Location Indoor or outdoor use Operating and
Storage Temperature -4° to 140° F (-20° to 60° C)
IP Rating IP67 Die cast aluminum converter (only when connected using compression gland seals)
Standard Outputs
Dual 4-20mA Outputs: Galvanically isolated and fully programmable for zero and full scale (0-21mA rangeability)
Two separate digital programmable outputs: open collector transistor usable for pulse, frequency, or alarm settings.
• Volumetric Pulse
• Flow Rate (Frequency)
• Hardware Alarm
• High/Low Flow Alarms
• Empty Pipe
• Directional Indication
• Range Indication
• Maximum switching voltage: 40 VDC
• Maximum switching current: 100mA
• Maximum switching frequency: 1250 Hz
• Insulation from other secondary circuits: 500V
Optional Outputs • Modbus
• HART
• Smart Output™ (Sensus, Itron 6, Itron 9)
• Datalogger
• Built-in verification
Display and Measurement
Keyboard and Display Can be used to access and change set-up parameters using six membrane keys and an LCD display
Engineering Units
• Cubic Meter
• Cubic Centimeter
• Milliliter
• Liter
• Cubic Decimeter
• Decaliter
• Hectoliter
• Cubic Inches
• US Gallons
• Imperial Gallons
• Cubic Feet
• Kilo Cubic Feet
• Standard Barrel
• Oil Barrel
• US Kilogallon
• Ten Thousands of Gallons
• Imperial Kilogallon
• Acre Feet
• Megagallon
• Imperial Megagallon
• Hundred Cubic Feet
• Megaliters
30121-75 Rev. 2.7 | 18JAN2024Page 15
PROCOMM CONVERTER SPECIFICATIONS (CONT.)
30124-60 Rev. 1.7 | 26OCT2022Page 43
SPECIFICATIONS
Other Speci� cations Standard Model • ISO 9001:2015 certi� ed quality management system
• Certi� ed by MET to UL 61010-1 / CSA C22.2 No. 61010-1
• Certi� ed to NSF / ANSI Standards*
HL Model • ISO 9001:2015 certi� ed quality management system
• Certi� ed by MET: Safety: UL61010-1 / CSA C22.2 No. 61010-1, Third
Edition: Safety of Electrical Equipment For Measurement, Control, and Laboratory Use
• Certi� ed by MET: Standards: ANSI / ISA12.12.01 / CSA C22.2 No. 213, Nonincendive Electrical Equipment
• Class I and II, Division 2
• Class III, Divisions 1 and 2 Hazardous (Classi� ed) Locations
• Certi� ed to NSF / ANSI Standards*
IMPORTANT
Electrical safety certi� cations above do not apply to model 282L Single Point Insertion (SPI Mag) Electromagnetic Flow Meter.
Refer to certi� cation requirements. Do not substitute components.
The ProComm converter, models PC-RA1-HL series and PC-MA1-HL series have no user serviceable parts.
30121-75 Rev. 2.7 | 18JAN2024Page 16
9.0 SPECIFICATIONS
Physical Speci� cations Electronic Housing Diecast aluminum, powder coated enclosure w/ tamper resistant seal, 6½” x 6½” x 43/8” tall
Converter Dimensions See "Dimensions" section for meter mount and remote mount converter dimensions.
Power
Battery: Standard: three 3.6V lithium-thionyl chloride (Li-SOCI2) D size batteries with two AA backup batteries
AC Power: 100-240VAC/45-66Hz (4W) DC Power: Linear power supply 10-35VDC (4 W)
Electrical Connections
• Optional shielded cable for 10-32VDC/4-20 mA output
• Optional shielded cable for pulse out
Performance and Operational Speci� cations Battery Life Five-year expected battery life, � ve-year battery warranty
Location Indoor or outdoor use
Altitude Operating: 2000 meters Storage: 12,000 meters
Operating Temperature -4° to 140° F (-20° to 60° C)
Storage Temperature -4° to 140° F (-20° to 60° C)
Relative Humidity 0% to 100%
IP Rating IP67 Die cast aluminum converter
Outputs
Digital output: Digital pulse (open collector) output for volumetric
- Two isolated digital pulse (open collector) outputs for volumetric
- AMI output
Analog output: 4-20mA: Galvanically Isolated, 16 Bit resolution. All power con� gurations (including battery).
Note: 9-30 VDC loop power required (not supplied via converter)
Display and Measurement
Display
• 2-Line LCD display (no backlight)
• Non-volatile memory
• Anti-reverse totalizer (standard)
• Total (to 9 digits of precision)
• Flow rate and velocity (to 5 digits of precision)
• Two alarms: low battery and empty pipe
(optional)
• Opening lid activates display
Digits 5 Rate, 9 Total
Units
GPM Gallons per minute MGD Mega gal per day CFS Cubic feet per second MLD Megaliters per day LPS Liters per second CMH Cubic meters per hour LPM Liters per minute GPH Gallons per hour
IGM Imperial gal per minute MI9 Miners inch (9G) MI1 Miners inch (11.22G) APD Acre feet per day KLH Kiloliters per hour LPH Liters per hour CMM Cubic meters per minute CFM Cubic feet per minute
CFM Cubic feet per minute B5M Barrels per minute (55G) B5H Barrels per hour (55G) B5D Barrels per day (55G) B4M Barrels per minute (42G) B4H Barrels per hour (42G) B4D Barrels per day (42G)
30125-72 Rev. 1.2 | 26OCT2022Page 20
SPECIFICATIONSProComm
PROCOMM GO CONVERTER SPECIFICATIONS
30121-75 Rev. 2.7 | 18JAN2024Page 17
Totalizer Units
GAL Gallons CUF Cubic Feet AFT Acre Feet CUM Cubic Meters LIT Liters MML Megaliter MTT Metric Ton (KL) B31 Barrel (31G)
B42 Barrel (42G) B46 Barrel (46G) B55 Barrel (55G) IMG Imperial Gallon AIN Acre Inch TON Ton (Short) MM1 Miners Inch Minute (11.22G) MM9 Miners Inch Minute (9G)
MH1 Miners Inch Hour (11.22G) MD1 Miners Inch Day (11.22G) MH9 Miners Inch Hour (9G) MD9 Miners Inch Day (9G) KGL Kilo Gallons MGL Mega Gallons IN3 Cubic Inch
Data Logger Standard with all models, minimum of � ve years of data stored
Other Speci� cations
Options and Accessories
• Data Logger - included as standard with � ve years of data storage at default (12hr) interval. (Cable sold separately)
• AC, DC, and battery powered with battery backup powered available
Safety • IEC 61010-1, Pollution Degree II
• Overvoltage protection Category III
Certi� cations
Standard Model
• ISO 9001:2015 certi� ed quality management system
• Certi� ed by MET to UL 61010-1 / CSA C22.2 No. 61010-1
• Certi� ed to NSF / ANSI Standards*
COMPONENT
NSF/ANSI/CAN 61
NSF/ANSI 372
I A P M O R & T
HL Model
• ISO 9001:2015 certi� ed quality management system
• Certi� ed by MET: Safety: UL61010-1 / CSA C22.2 No.
61010-1, Third Edition: Safety of Electrical Equipment For Measurement, Control, and Laboratory Use
• Certi� ed by MET: Standards: ANSI / ISA12.12.01 / CSA C22.2 No. 213, Nonincendive Electrical Equipment
• Class I and II, Division 2
• Class III, Divisions 1 and 2 Hazardous (Classi� ed)
Locations
• Certi� ed to NSF / ANSI Standards*
* Certi� ed by IAPMO R&T to NSF/ANSI 61 for material safety and NSF/ANSI 372 for low lead content.
30125-72 Rev. 1.2 | 26OCT2022Page 21
SPECIFICATIONSProComm
30121-75 Rev. 2.7 | 18JAN2024Page 18
PROCOMM CONVERTER DIMENSIONSRemote Mount Converter Dimensions Height 7.3" (18.5 cm)
Width 8.5" (21.6 cm)
Depth 4.3" (10.9 cm)
4.3"
2.25"
C TO C
7.5" C TO C
7.3"
7.0"
8.5"
L
L L
L
10.1"
8.2"
140º
30124-60 Rev. 1.7 | 26OCT2022Page 45
DIMENSIONS
30121-75 Rev. 2.7 | 18JAN2024
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
www.mccrometer.com
Copyright © 2022 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing, technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.
PROCOMM GO CONVERTER DIMENSIONS
10.0 DIMENSIONS
6.44"
6.94"
4.34"
6.94"
8.8”
8.8”
Meter mount converter
Remote mount converter
30125-72 Rev. 1.2 | 26OCT2022Page 22
DIMENSIONSProComm
4.8”
6.4”
File details come from the government source that posted it. Updated .