This is a specification document and Invitation for Bid (IFB) issued by the Missouri Department of Transportation (MoDOT) and Missouri Highways and Transportation Commission (MHTC) for the provision of Type III Movable Barricades. The barricades must be four feet wide and comply with the specification MGS-09-01B, which requires them to consist of three horizontal panels mounted to support structures capable of remaining upright and free-standing. The panels shall be constructed from high-density polyethylene, wood, or other approved materials and must feature MoDOT Type 4 retroreflective sheeting applied to both sides in reverse image configuration. All barricades must be MASH Test Level 3 certified in five deployment configurations: as a stand-alone device, with two lightweight warning lights, with a lightweight substrate sign, with both lights and sign, and with a MASH compliance label on the post. The contract period runs from November 1, 2026, through October 31, 2029, with two optional one-year renewal periods. Bids will be accepted electronically through MissouriBUYS MOVERS or by mail via USPS, UPS, or FedEx, with bidders intending to submit hard copy bids required to notify buyer Ashten Lorts five business days before the solicitation closing date.

The barricades will be supplied on an as-needed, if-needed basis, with acceptance determined by manufacturer certification and any additional testing the department deems necessary for specification compliance. No specific pricing terms, set-asides, incumbent information, or funding amounts are detailed in the specification document. Interested vendors should contact Ashten Lorts at ashten.lorts@modot.mo.gov or (573) 751-3685 for questions regarding the solicitation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MGS-09-01B

(Page 1 of 2)

(New 08-21-19)

FOUR-FOOT TYPE III MOVEABLE BARRICADE (MGS-09-01B)

1.0 DESCRIPTION. This specification covers four-foot wide Type III Moveable Barricades.

2.0 GENERAL. The four-foot wide Type III barricade shall consist of three horizontal panels mounted to supports in such a manner that the entire assembly is capable of remaining upright and entirely free standing.

2.1 SUPPORT. The support structure shall consist of a minimum of two uprights capable of keeping the panels securely attached in the designated arrangement shown in Figure 1. The uprights shall be mounted to a base capable of supporting the entire assembly while remaining completely portable.

2.2 PANELS. The panels shall consist of a substrate of high-density polyethylene, wood, or other approved material in the dimensions shown in Figure 1. Nominal dimensions will be allowed for dimensional lumber. MoDOT Type 4 retroreflective sheeting in accordance with Sec 1042 shall be applied as shown in Figure 1 to one side of each panel and in the reverse image on the opposite side of each panel.

3.0 MASH CERTIFICATION. The manufacturer shall provide written certification the four-foot wide Type III barricade provided complies with this specification and with the requirements of MASH, Test Level 3 when deployed as follows:

a) a stand alone device,

b) a device with two lightweight warning lights,

c) a device with a lightweight substrate sign,

d) a device with two lightweight warning lights and a lightweight substrate sign, and

e) a label on the post identifying MASH compliance.

4.0 ACCEPTANCE. Acceptance of four-foot wide Type III barricades will be by certification and any tests deemed necessary by the department for compliance with this specification.

4-FOOT Type III Moveable Barricade

MGS-09-01B

(Page 1 of 2)

(New 08-21-19)

Figure 1:

FOUR-FOOT WIDE TYPE III MOVEABLE BARRICADE