FOR_REFERENCE_ONLY_-_PRCRC_Flooring_&_Waterproofing_Set_.pdf
PDF 7 MB Posted
- Attached to
- Pleasant Ridge Flooring Repair & Waterproofing
- Solicitation number
- RFP #27035
- Issued by
- Greenville County, South Carolina
About this file
Summary
This is an architectural drawing set for flooring repair and waterproofing work at Pleasant Ridge, a County of Greenville facility located at 4232 Highway 11, Marietta, SC 29661. The project encompasses flooring and waterproofing improvements to wet rooms (bathrooms, shower rooms, and toilet rooms) across eight cabins containing 24 shower spaces—16 shower-only rooms and 8 full bathrooms with toilets and sinks. The scope of work includes demolition of existing ceramic tile flooring and wall tile, removal and storage of plumbing fixtures for reuse, repair or replacement of damaged wooden floor joists using sistering techniques with pressure-treated lumber, installation of new plywood subflooring with self-leveling compound, and installation of new sheet vinyl flooring (Altro Aquarius) with six-inch flash cove integration and floor drains. New moisture-resistant gypsum wallboard and fiberglass reinforced plastic (FRP) finish will be applied to wet walls in shower and toilet rooms, with existing fixtures to be reinstalled with new installation kits. The drawings indicate existing conditions and new construction details across multiple sheets (A-101 Floor Plan, AD-101 Demolition Plans, A-401 and A-402 Enlarged Plans, and A-720 Finish Plan), with specific dimensions, material specifications, and construction notes provided throughout.
The project documents specify Altro Aquarius sheet flooring in Otter color with heat-welded seams, Panolam fiberglass reinforced plastic panels for wet wall protection, and Sherwin Williams Promar 200 paint finish. An alternate (Alternate A) provides for FRP installation on walls behind toilets in single toilet rooms. Contractors are required to provide unit cost pricing per square foot for removing and replacing damaged subfloor, coordinate with the architect and interior designer prior to material ordering and installation, submit finish samples for approval, and maintain proper documentation of existing fixture locations for reinstallation. All existing plumbing fixtures, toilet accessories, and fixtures must be cleaned and reinstalled using new installation kits, with the contractor responsible for any damages occurring during construction at no cost to the owner.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pleasant_Ridge_Flooring_Repair_&_Waterproofing.pdf | ||
| COG_Sub_W9_.pdf | ||
| Sample_Services_Agreement.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROOM NAME
150 SF
SUBSYSTEM
TYPICAL DIMENSION INDICATOR
DETAIL/PLAN KEY
SECTION KEYS
DIRECTION OF
SECTION
ELEVATION KEY
REVISION INDICATION
REVISION NUMBER
AREA REVISED
DOOR NUMBER
GLASS TYPE
DRAWING
TITLE
DRAWING NAME
DRAWING SCALE
ENLARGED DETAIL INDICATOR
DIRECTION OF SECTION
TERMINATION OF SECTION
DRAWING LOCATION ON SHEET GRID
DETAIL LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF DETAIL
BUILDING SECTION LOCATION
ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF SECTION
WALL SECTION LOCATION ON SHEET
GRID
SHEET IDENTIFIER FOR
LOCATION OF SECTION
DETAIL LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF DETAIL
COLUMN GRID REFERENCE
TERMINATION OF SECTION
DRAWING NAME
DRAWING SCALE
DRAWING LOCATION ON SHEET GRID
SHEET NUMBER WHERE DETAIL IS REFERENCED
SHEET NUMBER WHERE DETAIL IS DRAWN
A
A1
PLAN
1/8" = 1'-0"
NTS
A1
PLAN
A101
A1
201A
CENTERLINE
9 1/2"
FLOOR ELEVATION
ROOM NAME & NUMBER
A
ELEVATION LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF ELEVATION
DIRECTION OF ELEVATION
A-201
A1
W1
A-201
A1
A-201
A1
A-201
A1
A-201
A1
1ST FLOOR
0'-0"
EARTH
POROUS FILL
(STONE OR GRAVEL)
ROCK
LIGHTWEIGHT CONCRETE
(OR CONCRETE FILL)
STRUCTURAL CONCRETE
(CAST IN PLACE, ETC.)
BRICK
(COMMON OR FACE)
CONC. MASONRY UNITS
(C.M.U.)
PLASTER, CEMENT,
SAND, GROUT
STEEL, IRON
ALUMINUM
WOOD (FINISH)
WOOD (ROUGH)
WOOD BLOCKING
PLAN AND SECTION
PLYWOOD
SPRAY-ON
FIREPROOFING
BATT/LOOSE FILL
INSULATION
EXTRUDED POLYSTYRENE
ACOUSTICAL TILE
GYPSUM WALLBOARD
CARPET AND PAD
BRICK
CERAMIC TILE
CONCRETE / PLASTER /
STUCCO
GLASS
SHINGLES/SIDING
MATERIAL LEGEND (NOT ALL MATERIALS APPLICABLE)
ELEVATION
POD C
POD B
C4
C3
C2
C1
B4
B3
B2
B1
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2018 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
TEL. 864.235.0405 FAX 864.233.4027
GREENVILLE, SOUTH CAROLINA 29601
110 WEST NORTH STREET SUITE 300
/2
/2
:5
:5
A
M
C
U s e rs
\c a it ly n s h a w
\D o c u m e n ts \A rc h
G re e n v il le
C o u n ty C a m p S p e a rh e a d
P le a s a n t R id g e c a it s h a w ls p
.c o m .r v t
3702-186030
23 October 2018
CHS
DO
PROJECT
INFORMATION
SHEET
G-001
Pleasant Ridge - Flooring Repair and Waterproofing
Permit & Construction
Camp Spearhead
GRAPHIC SYMBOL LEGEND
SHEET INDEX
SHEET NO. SHEET NAME SHT REV NO. SHT REV DATE REVISION DESCRIPTION
G-001 PROJECT INFORMATION SHEET
GENERAL
ARCHITECTURAL
LS3P
110 WEST NORTH STREET, SUITE 300
GREENVILLE, NC 29601
tel: 864.235.0405 email: deanoang@ls3p.com
Pleasant Ridge - Flooring Repair and Waterproofing
3702-186030
Permit & Construction4232 SC-11 Marietta, SC 29661
23 October 2018
SHEET NO. SHEET NAME SHT REV NO. SHT REV DATE REVISION DESCRIPTION
A-101 FLOOR PLAN & PROJECT INFORMATION
AD-101 DEMOLITION PLANS AND DETAILS
A-401 ENLARGED PLANS AND DETAILS
A-402 ENLARGED PLANS AND DETAILS
A-720 FINISH PLAN
TOJ TOP OF JOIST
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF SLAB
TOW TOP OF WALL
TRTD TREATED
TV TELEVISION
TYP TYPICAL
UL UNDERWRITERS
LABORATORIES
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
W WEST, WIDE
W/ WITH
W/O WITHOUT
W/W WALL TO WALL
WC WATER CLOSET
WD WOOD
WP WORKING POINT,
WATERPROOFING
WR WATER REPELLENT
WT WEIGHT
WWF WELDED WIRE FABRIC
YD YARD
NOM NOMINAL
NON
COMB
NON-COMBUSTIBLE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPP OPPOSITE
OPT OPTION(AL)
PCF POUNDS PER CUBIC FEET
PLAM PLASTIC LAMINATE
PLF POUNDS PER LINEAR FEET
PLYWD PLYWOOD
PNL PANEL
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISH
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, POST-TENSIONED,
PRE-TREATED
PVC POLYVINYL CHLORIDE
(PLASTIC)
QTR QUARTER
QTY QUANTITY
R RADIUS, RISER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR, REFERENCE
REQD REQUIRED
RL ROOF LEADER
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
S SOUTH
SC SOLID CORE
SD STORM DRAIN
SECT SECTION
SF SQUARE FEET
SIM SIMILAR
SPEC SPECIFICATION
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STOR STORAGE
SUSP SUSPENDED
SYS SYSTEM
T TREAD
TEL TELEPHONE
TEMP TEMPORARY
TFF TOP OF FINISH FLOOR
THK THICKNESS
THRU THROUGH
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE, CURB
TOF TOP OF FOOTING
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF EL FINISH FLOOR ELEVATION
FHC FIRE HOSE CABINET
FIN FLR FINISHED FLOOR
FLR FLOOR, FILLER
FOC FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB
FOW FACE OF WALL
FT FOOT, FEET
FTG FOOTING
FURN FURNISH, FURNITURE
GA GAGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
HC HANDICAP
HD HEAVY DUTY
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATION & AIR
CONDITIONING
ID INSIDE DIAMETER
INCL INCLUDE(D), (ING)
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
JAN CLO JANITOR CLOSET
KIT KITCHEN
KO KNOCKOUT
LAB LABORATORY
LAM LAMINATE
LAU LAUNDRY
LAV LAVATORY
LF LINEAR FEET
LVR LOUVER
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFG MANUFACTURING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTD MOUNTED
MTG MOUNTING
MTL METAL
N NORTH
NIC NOT IN CONTRACT
A/C AIR CONDITION(ING)
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE(LY)
ARCH ARCHITECT(URAL)
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIOVISUAL
BITUM BITUMINOUS
BL BUILDING LINE
BLDG BUILDING
BN BULL NOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
CAB CABINET
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLO CLOSET
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUE. CONTINUOUS
CORR CORRIDOR
CU FT CUBIC FOOT
CU YD CUBIC YARD
DEMO DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DS DOWNSPOUT
E EAST
EA EACH
EIFS EXTERIOR INSULATION &
FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
ENCL ENCLOSE(D)
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP JT EXPANSION JOINT
EXT EXTERIOR
F/F FACE TO FACE
FD FLOOR DRAIN
ABBREVIATIONS
AREA AND VICINITY MAP
EXISTING BUILDING ALTERATION - LEVEL 01 PER IBC 2015
ARCHITECTURAL
No. Description Date
WH
W /D
WH
W /D
WH
W /D
WH
W /D
E E
F F
G G
16'-1 5/8" 20'-0" 20'-0" 20'-0" 16'-1 5/8"
A A
B B
'-0
'-0
'-0
C C
D D
5.5
5.5
1'-6 3/4" 1'-6 3/4"
/8
8'-8"
32'-1 5/8"
8'-8"
32'-1 5/8"
A-401
C1
/8
/4
AD-101
C3
TYPICAL POD LAYOUT - POD "C" SHOWN
CABIN C1
(CABIN B1)
CABIN C4(CABIN B4)
CABIN C3
(CABIN B3)
CABIN C2
(CABIN B2)
A-720
C1
LAVATORY
SHOWER
SHOWER
TOILET
TOILET
LAVATORY
SHOWER
SHOWER
TOILET
TOILET
BATHROOM
LAVATORY
SHOWER
SHOWER
TOILET
TOILET
BATHROOM
LAVATORY
SHOWER
SHOWER
TOILET
TOILET
BATHROOM
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
ALL DIMENSIONS SHALL BE VERIFIED BY THE
CONTRACTOR IN THE FIELD PRIOR TO WORK
BEGINNING. CONTRACTOR SHALL BE
RESPONSIBLE FOR MINOR ADJUSTMENTS IN
THE FIELD. MAJOR DISCREPANCIES SHALL
BE BROUGHT TO THE OWNERS &
ARCHITECTS ATTENTION.
NOT IN
SCOPE
BATHROOM
1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.
2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.
3. SEE SHEETS A-720 FOR FINISH FLOORING, TRANSITIONS, PATTERNS AND WALL
PROTECTION.
4. SEE SHEET A-720 FOR FINISH SCHEDULE.
5. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES THAT ARE
REMOVED SHALL BE CLEANED AND REINSTALLED USING NEW INSTALLATION
KITS.
6. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING
FINISH SHALL REMAIN AS IS.
7. REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE,
PLACE ACCESSORIES BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS
RESPONSIBLE FOR DOCUMENTING AND REUSING MOUNTING HEIGHTS AND
LOCATIONS.
GENERAL NOTES
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2018 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
TEL. 864.235.0405 FAX 864.233.4027
GREENVILLE, SOUTH CAROLINA 29601
110 WEST NORTH STREET SUITE 300
/2
/2
:5
:0
A
M
C
U s e rs
\c a it ly n s h a w
\D o c u m e n ts \A rc h
G re e n v il le
C o u n ty C a m p S p e a rh e a d
P le a s a n t R id g e c a it s h a w ls p
.c o m .r v t
3702-186030
23 October 2018
CHS
DO
FLOOR PLAN &
PROJECT
INFORMATION
A-101
Pleasant Ridge - Flooring Repair and Waterproofing
Permit & Construction
Camp Spearhead
N
TRUE
NORTH
N
1/8" = 1'-0" A1
TYPICAL POD FLOOR PLAN
/D
WH
W /D
WH
W /D
WH
W /D
E E
F F
5.5
5.5
DEMO EXISTING FLOOR DRAINS.
REMOVE EXISTING PREFAB SHOWER
UNITS, CURTAIN RODS, GRAB BARS,
AND SHOWER PLUMBING FIXTURES
AND STORE FOR REUSE. CONTRACTOR
TO PROVIDE STORAGE LOCATION.
DEMO EXISTING FLOOR DRAINS.
REMOVE EXISTING PREFAB SHOWER
UNITS, CURTAIN RODS, GRAB BARS, AND
SHOWER PLUMBING FIXTURES AND STORE
FOR REUSE. CONTRACTOR TO PROVIDE
STORAGE LOCATION.
REMOVE EXISTING TOILETS AND STORE
FOR REUSE. CONTRACTOR TO PROVIDE
STORAGE LOCATION.
B4
AD-101
EXISTING COUNTERTOPS, SINKS AND
FAUCETS TO REMAIN. PROTECT AS
REQUIRED DURING ALL
CONSTRUCTION ACTIVITY, TYPICAL.
EXISTING COUNTERTOPS, SINKS AND
FAUCETS TO REMAIN. PROTECT AS
REQUIRED DURING ALL CONSTRUCTION
ACTIVITY, TYPICAL.
NOTE: CONTACT OWNER / ARCHITECT IF ANY FIXTURES, WALLS, DOORS, OR CASEWORK APPEAR TO HAVE WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION. CONTACT OWNER / ARCHITECT IF STRUCTURAL INTEGRITY APPEARS TO BE COMPROMISED AS A RESULT OF WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION.
ANY DAMAGES THAT OCCUR DURING CONSTRUCTION WILL BE REPAIRED AND/OR REPLACED AT NO COST TO THE
OWNER.
A1
AD-101
CABIN B3, C3 CABIN B2, C2
WALL TILE AND GRAB BARS IN TOILET
ROOMS; SEE ALTERNATE A.
DEMO WALL TILE IN SHOWER
ROOMS.
REMOVE EXISTING PREFAB SHOWER
UNITS, CURTAIN RODS, GRAB BARS,
AND SHOWER PLUMBING FIXTURES
AND STORE FOR REUSE. CONTRACTOR
TO PROVIDE STORAGE LOCATION.
REMOVE EXISTING PREFAB SHOWER
UNITS, CURTAIN RODS, GRAB BARS, AND
SHOWER PLUMBING FIXTURES AND STORE
FOR REUSE. CONTRACTOR TO PROVIDE
STORAGE LOCATION.
LAVATORY
LAVATORY
NOT IN
SCOPE
SHOWER
SHOWER
TOILET
TOILET
BATHROOM
BATHROOM
TOILET
TOILET
SHOWER
SHOWER
DEMO WALL TILE IN SHOWER
ROOMS.
WALL TILE AND GRAB BARS IN TOILET
ROOMS; SEE ALTERNATE A.
DEMO EXISTING FLOOR DRAINS.
DEMO ALL CERAMIC TILE FLOORING
AND CERAMIC TILE BASE
THROUGHOUT TOILETING / BATHING /
VANITY AREAS.
DEMO ALL CERAMIC TILE FLOORING
AND CERAMIC TILE BASE
THROUGHOUT TOILETING / BATHING /
VANITY AREAS.
REMOVE EXISTING TOILETS AND
STORE FOR REUSE. CONTRACTOR TO
PROVIDE STORAGE LOCATION.
DEMO SUBFLOOR IN TOILETING/BATHING ROOMS
D E
M O
S U
B F
L O
O R
I N
T O
IL
E
T
IN
G /B
A T
H
IN
G R
O O
M S
PROVIDE UNIT COST PER SF ON REMOVING AND
REPLACING DAMAGED SUBFLOOR.
D5
A-401
1ST FLOOR
0' - 0"
REMOVE DAMAGED SPRAY FOAM
INSULATION AS NEEDED; INSULATION
WITHOUT WATER OR CONSTRUCTION
DAMAGE SHALL REMAIN
REMOVE TILE FLOORING AND TILE BASE (ALL
BATHING / TOILETING ROOMS)
REMOVE PLYWOOD SUBFLOOR THROUGHOUT
SHOWER AND TOILET ROOMS
EXISTING 2X12 WOOD JOISTS SHALL REMAIN
SEE A4 / A-401 FOR SCOPE OF WORK IF JOIST
IS DAMAGED.
NOTE: CONTACT OWNER / ARCHITECT IF ANY FIXTURES, WALLS, DOORS, OR CASEWORK APPEAR TO HAVE WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION. CONTACT OWNER / ARCHITECT IF STRUCTURAL INTEGRITY APPEARS TO BE COMPROMISED AS A RESULT OF WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION.
ANY DAMAGES THAT OCCUR DURING CONSTRUCTION WILL BE REPAIRED AND/OR REPLACED AT NO COST TO THE
OWNER.
REMOVE TILE AND GYPSUM WALL BOARD @ SHOWER
ROOM. EXISTING DRYWALL IN SHOWER ROOMS
WITHOUT TILE SHALL REMAIN.
WALL TILE IN TOILET ROOMS: SEE ALTERNATE A.
EXISTING STRUCTURAL INSULATION WALL (EXTERIOR
WALLS)
EXISTING 2X6 STUD FRAMING IN "DOUBLE" CABIN
UNITS
INSPECT ALL SILL PLATES AND BASE OF WALL STUDS FOR
WATER OR OTHER DAMAGE. REPORT ANY DAMAGE
IMMEDIATELY TO THE ARCHITECT.
1ST FLOOR
0' - 0"
WALL TILE AND GRAB BARS IN TOILET ROOMS;
SEE ALTERNATE A.
REMOVE EXISTING TOILETS AND STORE
FOR REUSE. CONTRACTOR TO PROVIDE
STORAGE LOCATION.
REMOVE EXISTING PREFAB SHOWER
UNITS, CURTAIN RODS, GRAB BARS,
AND SHOWER PLUMBING FIXTURES
AND STORE FOR REUSE. CONTRACTOR
TO PROVIDE STORAGE LOCATION.
EXISTING PREFAB SHOWER UNITS,
CURTAIN RODS, GRAB BARS, AND SHOWER
PLUMBING FIXTURES SHALL BE REMOVED
FOR REUSE IN EXISTING LOCATION.
REMOVE WALL TILE IN ALL SHOWER
ROOMS. Existing Tile Height
5' - 10"
Ceiling Height 9' - 0"
1. CONTRACTOR TO PERFORM DEMOLITION WORK AS REQUIRED PER WORK
SEQUENCE.
2. DEMOLITION DRAWINGS ARE INTENDED TO SHOW GENERAL AREAS OF
DEMOLITION AS WELL AS GENERAL EXISTING CONDITIONS. THEY DO NOT
SHOW ALL WORK WHICH MAY BE NECESSARY. COMPARE WITH DRAWINGS
INDICATING NEW CONSTRUCTION.
3. EXISTING WORK TO REMAIN SHALL BE TEMPORARILY SECURED, BRACED AND
STABILIZED UNTIL PERMANENT CONSTRUCTION IS IN PLACE.
4. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES SHALL BE
PROPERLY STORED FOR REUSE FOLLOWING THE COMPLETION OF FINISH
INSTALLATION. STORAGE LOCATION TO BE PROVIDED BY CONTRACTOR.
5. VERIFY FIELD CONDITIONS PRIOR TO START OF DEMOLITION/CONSTRUCTION
AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
6. VERIFY THAT CONSTRUCTION INDICATED FOR REMOVAL IS NOT LOAD
BEARING OR IS ADEQUATELY SHORED AS REQUIRED.
7. ERECT BARRICADES, FENCES OR OTHER SECURABLE MEANS TO PREVENT
UNAUTHORIZED ACCESS INTO CONSTRUCTION ZONES.
8. DO NOT ALLOW MATERIAL AND DEBRIS GENERATED BY DEMOLITION
ACTIVITIES TO ACCUMULATE ON THE JOB SITE. REMOVE DAILY AND DISPOSE
OF IN A LEGAL MANNER. NO ON-SITE SALE OR BURNING OF REMOVED ITEMS
IS PERMITTED.
9. THE CONTRACTOR MUST MAINTAIN ADEQUATE SUPPORT INSULATION,
WATERPROOFING, EMERGENCY LIGHTING, SECURITY, ALARMS, ETC. FOR ALL
OR PART OF ITEMS WHICH ARE TO REMAIN.
10. PREPARE AND PATCH SURFACES THAT RECEIVE NEW FINISHES AS REQUIRED
BY REMOVING OR RELOCATING DEVICES, WIRING OR OTHER
APPURTENANCES NO LONGER APPROPRIATE FOR THE NEW USE OF THE
ROOM.
11. MAINTAIN EXISTING FINISHES, OPERATIONAL CHARACTERISTICS, AND
APPEARANCE OF ITEMS SCHEDULED TO REMAIN OR BE REUSED.
12. ANY DAMAGE TO THE EXISTING STRUCTURE CAUSED BY THE CONTRACTOR
WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO COST TO THE
OWNER.
DEMOLITION PLAN SHEET NOTES
1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.
2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.
3. SEE SHEETS A-720 FOR FINISH FLOORING, TRANSITIONS, PATTERNS AND WALL
PROTECTION.
4. SEE SHEET A-720 FOR FINISH SCHEDULE.
5. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES THAT ARE
REMOVED SHALL BE CLEANED AND REINSTALLED USING NEW INSTALLATION
KITS.
6. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING
FINISH SHALL REMAIN AS IS.
7. REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE,
PLACE ACCESSORIES BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS
RESPONSIBLE FOR DOCUMENTING AND REUSING MOUNTING HEIGHTS AND
LOCATIONS.
GENERAL NOTES
E E
F F
5.5
5.5
NOTE: CONTACT OWNER / ARCHITECT IF ANY FIXTURES, WALLS, DOORS, OR CASEWORK APPEAR TO HAVE WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION. CONTACT OWNER / ARCHITECT IF STRUCTURAL INTEGRITY APPEARS TO BE COMPROMISED AS A RESULT OF WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION.
ANY DAMAGES THAT OCCUR DURING CONSTRUCTION WILL BE REPAIRED AND/OR REPLACED AT NO COST TO THE
OWNER.
CABIN B3, C3 CABIN B2, C2
NOT IN
SCOPE
5'-1 1/2"
4'-8"
2'-7 3/8" 6'-9"
/4
/4
/8
/8
/8
/8
/8
5'-1 1/4"2'-7 3/8"
4'-8"
6'-9"
ALL DIMENSIONS SHALL BE VERIFIED BY THE
CONTRACTOR IN THE FIELD PRIOR TO WORK
BEGINNING. CONTRACTOR SHALL BE
RESPONSIBLE FOR MINOR ADJUSTMENTS IN
THE FIELD. MAJOR DISCREPANCIES SHALL
BE BROUGHT TO THE OWNERS &
ARCHITECTS ATTENTION.
6'-9" 6'-9"8'-1 1/2" 8'-1 3/4"
EXISTING FLOOR DRAINS
(TYPICAL)
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2018 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
TEL. 864.235.0405 FAX 864.233.4027
GREENVILLE, SOUTH CAROLINA 29601
110 WEST NORTH STREET SUITE 300
/2
/2
:5
:1
A
M
C
U s e rs
\c a it ly n s h a w
\D o c u m e n ts \A rc h
G re e n v il le
C o u n ty C a m p S p e a rh e a d
P le a s a n t R id g e c a it s h a w ls p
.c o m .r v t
3702-186030
23 October 2018
Author
Checker
DEMOLITION
PLANS AND
DETAILS
AD-101
Pleasant Ridge - Flooring Repair and Waterproofing
Permit & Construction
Camp Spearhead
1/4" = 1'-0" C3
DEMOLITION PLAN: DOUBLE POD TOILET/BATHING AREA
TYPICAL DOUBLE CABIN
1 1/2" = 1'-0" B4
WALL SECTION - EXST CONDITION @ FLOOR
1/4" = 1'-0"
A1
TYPICAL WET WALLS IN TOILET/BATHING AREAS - DEMOLITION
ALTERNATES
ALTERNATE A: DEMO CERAMIC TILE ON
WALLS IN TOILET ROOMS. REMOVE GRAB
BARS IN TOILET ROOMS AND STORE FOR
REUSE. CONTRACTOR TO PROVIDE
STORAGE LOCATION.
1/4" = 1'-0" C1
EXISTING FLOOR PLAN: DOUBLE POD TOILET/BATHING AREA
TYPICAL DOUBLE CABIN
/D
WH
W /D
1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.
2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.
3. SEE SHEETS A-720 FOR FINISH FLOORING, TRANSITIONS, PATTERNS AND WALL
PROTECTION.
4. SEE SHEET A-720 FOR FINISH SCHEDULE.
5. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES THAT ARE
REMOVED SHALL BE CLEANED AND REINSTALLED USING NEW INSTALLATION
KITS.
6. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING
FINISH SHALL REMAIN AS IS.
7. REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE,
PLACE ACCESSORIES BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS
RESPONSIBLE FOR DOCUMENTING AND REUSING MOUNTING HEIGHTS AND
LOCATIONS.
GENERAL NOTES
5 6
E E
F F
5.5
NEW SHEET VINYL FLOORING.
A1
A-401
INSTALL NEW 7" FLOOR DRAINS IN ORIGINAL LOCATIONS IN
CONJUNCTION WITH NEW SHEET VINYL FLOORING PER
MANUFACTURER'S INSTALLATION INSTRUCTIONS. SEE E4 /
A-401. CONNECT TO EXISTING PIPING. CONTRACTOR IS
RESPONSIBLE FOR DOCUMENTING AND INSTALLING NEW
FLOOR DRAINS IN ORIGINAL LOCATIONS (TYPICAL).
A-402
A1
LAVATORY
SHOWER
SHOWER
TOILET
TOILET
STORAGE /
LAUNDRY
BATHROOM
LAVATORY
SHOWER
SHOWER
TOILET
TOILET
STORAGE /
LAUNDRY
BATHROOM
D4
A-401
USE SELF-LEVELING COMPOUND TO LEVEL THE SUBFLOOR AS
NEEDED BEFORE FINAL UNDERLAYMENT PLYWOOD LAYER IS
INSTALLED SEE D4 / A-401.
SHOWER ROOMS, TOILET ROOMS, AND BATHROOMS TO
RECEIVE NEW SUBFLOOR, SEE D4 / A-401.
SEE FINISH PLAN AND SCHEDULE FOR
TRANSITION SPECIFICATION.
A-401B1
NOT IN
SCOPE
CLEAN AND REINSTALL NEW TOILET AND SHOWER
FIXTURES WITH NEW INSTALLATION KITS, TYPICAL.
D4
A-401
D5
A-401
1ST FLOOR
0' - 0"
FLASH COVE BASE.
REINSTALL GRAB BARS IN ORIGINAL LOCATIONS OVER NEW
DRYWALL AND FINISH.
A-401
D4 A-401
E4
REINSTALL PLUMBING FIXTURES IN ORIGINAL LOCATIONS OVER
NEW FLOORING.
NEW FRP APPLIED TO NEW MOISTURE-RESISTANT GYPSUM WALL
BOARD TO EXTEND FROM COVED BASE TO HEIGHT OF SHOWER.
SEE FINISH PLAN AND SCHEDULE FOR FRP SPECIFICATION.
Existing Tile Height 5' - 10"
Ceiling Height 9' - 0"
TOILET ROOM WALL TILE TO REMAIN; SEE ALTERNATE A.
SHEET FLOORING TO RUN UNDER ENTRY EDGE OF
SHOWER FOR 2" MINIMUM.
NEW 1/2" PLYWOOD C/D EXTERIOR GRADE T & G
SUBSTRATE.
NEW 1/2" EXTERIOR GRADE T & G. SANDED FACE
PLYWOOD UNDERLAYMENT; APA TRADEMARKED
PLYWOOD OF GRADE C-C PLUGGED OR BETTER
(OR EQUIVALENT).
CLEAN AND REINSTALL EXISTING TOILET AND SHOWER
FIXTURES WITH NEW INSTALLATION KITS, TYPICAL.
CLEAR MILDEW-RESISTANT SILICONE CAULK JOINT
WHERE SHOWER FIXTURE EDGE MEETS SHEET
FLOORING (SEE A-720).
FEATHERED SELF-LEVELING COMPOUND AS
NEEDED BETWEEN PLYWOOD LAYERS
1ST FLOOR
0' - 0"
NEW CLOSED CELL SPRAY FOAM
INSULATION AS NEEDED; INSULATION
SHALL BE APPLIED 4" THICK TO ENSURE
PROPER THERMAL R-VALUE
ALTRO AQUARIUS SHEET FLOORING
WITH 6" FLASH COVE INTEGRATION.
NEW 1/2" PLYWOOD C/D EXTERIOR
GRADE T & G SUBSTRATE.
EXISTING 2X12 WOOD JOISTS SHALL
REMAIN
NOTE: ALL MATERIALS USED SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. SAMPLES OF ALL FINISH SELECTIONS SHALL BE CONFIRMED BY OWNER / ARCHITECT PRIOR TO INSTALLATION.
FLOORING MUST BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.
REINFORCE DAMAGED EXISTING 2X12
WOOD JOISTS BY SISTERING NEW
PRESSURE TREATED 2X12 WOOD JOISTS
ON EITHER SIDE SECURED NEW JOISTS
TO EXISTING JOIST WITH TIMBERLOK
SCREWS (TWO ROWS @ 16" O.C.).
NEW 5/8" MOISTURE-RESISTANT GYPSUM
WALL BOARD (UNPAINTED AND
UNPRIMED) ON WET WALLS UP TO
HEIGHT OF SHOWER.
NEW 1/2" EXTERIOR GRADE T & G.
SANDED FACE PLYWOOD
UNDERLAYMENT; APA TRADEMARKED
PLYWOOD OF GRADE C-C PLUGGED OR
BETTER (OR EQUIVALENT).
FIBERGLASS REINFORCED PLASTIC (FRP)
FINISH APPLIED TO GYPSUM WALL BOARD
SURFACE ON WET WALLS UP TO HEIGHT
OF SHOWER. USE CRANE ADVANCED
POLYMER ADHESIVE (OR EQUIVALENT).
A-401
C4
EXISTING PLUMBING FIXTURES IN
CONTACT WITH FLOORING WILL BE
REINSTALLED WITH NEW INSTALLATION
KIT. THIS APPLIES TO ALL SHOWER
UNITS AND TOILETS.
FEATHERED SELF-LEVELING
COMPOUND AS NEEDED BETWEEN
PLYWOOD LAYERS.
NEW WALL FINISHES IN SHOWER
ROOMS.
TOILET TILE WALL TO REMAIN IN BASE
BID, SEE ALTERNATE A FOR UPGRADE
OPTION.
PROVIDE SIMPSON STRONG TIES FOR
JOIST CONNECTION (VERIFY CONDITION
IN THE FIELD (TYPICAL AT LOCATIONS).IF EXISTING WOOD JOIST IS
COMPLETELY UNSALVAGEABLE,
REPLACE AS NEEDED.
1. PRIOR TO INSTALLATION AND FABRICATION, CONTRACTOR SHALL COORDINATE
WITH ARCHITECT AND INTERIOR DESIGNER TO REVIEW ALL FLOOR PATTERNS,
FINISHES AND DOCUMENTATION INFORMATION.
2. PRIOR TO PAINTING, PAINTING CONTRACTOR SHALL SUBMIT TO
ARCHITECT/INTERIOR DESIGNER EACH PAINT COLOR FINISH ON A 8 1/2" X 11" SHEET
OF CHIPBOARD FOR PRELIMINARY APPROVAL. FOR FINAL APPROVAL BY OWNER AND
ARCHITECT PRIOR TO PAINTING, THE PAINTING CONTRACTOR SHALL VERIFY PAINT
COLOR MATCH OF EXISTING WALL FINISH.
3. INSTALLERS OF EACH FINISH MATERIAL SHALL INSPECT BOTH THE SUBSTRATE
AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. INSTALLER SHALL NOT
PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN AN
ACCEPTABLE MANNER TO ALL PARTIES AND MEET ALL MANUFACTURER'S
REQUIREMENTS.
4. ALL INTERIOR FINISHES SHALL COMPLY WITH SECTION 803 OF RESTRICTIONS OF
COMBUSTIBLE MATERIALS OF THE INTERNATIONAL BUILDING CODE. ALL INTERIOR
FINISHES SHALL BE CLASS B OR BETTER.
5. THE INTENT IS TO PROVIDE A COMPLETE FINISHED INTERIOR WHETHER OR NOT
SPECIFICALLY INDICATED. ITEMS SHALL BE FINISHED AND/OR PAINTED AS DIRECTED
BY DESIGNER, WHETHER OR NOT SPECIFICALLY SCHEDULED OR INDICATED ON
DRAWINGS.
6. INSTALL TRANSITION STRIP AT THRESHOLD WHERE DIFFERING FLOORING
MATERIALS ABUTT, UNLESS OTHERWISE NOTED. COORDINATE COLOR/FINISH WITH
DESIGNER.
7. ALL FLOOR FINISH CHANGES / TRANSITIONS SHALL OCCUR AT THE CENTER LINE
OF CLOSED DOORS.
8. FLOOR PATTERN TO CONTINUE UNDER ALL OPEN WOODWORK/ WORKSURFACES.
9. PRIOR TO ORDERING, SUB-CONTRACTORS FOR FLOORING, PAINTING, AND
MILLWORK SHALL SUBMIT TO ARCHITECT / INTERIOR DESIGNER AN 8" X 8" SAMPLE OF
EACH MATERIAL SPECIFIED FOR FINAL APPROVAL.
10. IF ANY DISCREPANCIES OR OMISSIONS ARE NOTED IN THESE DRAWINGS,
CONTACT INTERIOR DESIGNER OR ARCHITECT PRIOR TO ORDERING OR
COMMENCING WORK.
11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK LEAD TIMES ON
FINISHES IN ORDER TO AVOID DELAYING WORK.
ROOM FINISH PLAN SHEET NOTES
1ST FLOOR
0' - 0"
NEW 5/8" MOISTURE-RESISTANT GYPSUM WALL
BOARD (UNPAINTED AND UNPRIMED) ON WET
WALLS.
WHERE SCHEDULED, FIBERGLASS REINFORCED
PLASTIC (FRP) FINISH SHALL BE APPLIED TO GYPSUM
WALL BOARD SURFACE ON WET WALLS UP TO
HEIGHT OF SHOWER. USE CRANE ADVANCED
POLYMER ADHESIVE (OR EQUIVALENT).
EXISTING WALL STRUCTURE TO REMAIN.
FLASH COVE CAP STRIP
NEW 1/2" PLYWOOD C/D EXTERIOR GRADE T &
G SUBSTRATE.
NEW 1/2" EXTERIOR GRADE T & G. SANDED FACE
PLYWOOD UNDERLAYMENT; APA TRADEMARKED
PLYWOOD OF GRADE C-C PLUGGED OR BETTER (OR
EQUIVALENT). THIS PRODUCT SHALL MEET ASTM
F1482 - 15 REQUIREMENTS.
1 1/2" COVE FORMER CONTINUOUS AROUND
PERIMETER WHERE FLOORING APPLICATION
MEETS VERTICAL WALLSV-1 FLOORING WITH 6" FLASH COVE INTEGRATION.
FEATHERED SELF-LEVELING COMPOUND AS NEEDED
BETWEEN PLYWOOD LAYERS.
F L
A S
H C
O V
E
1ST FLOOR
0' - 0"
NOTE: ALL MATERIALS AND FIXTURES USED SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.
FLOOR DRAIN BASIS OF DESIGN: MIFAB F1100-FC 7" DIAMETER FLOOR DRAIN WITH SURFACE MEMBRANE
CLAMP. EQUIVALENT FIXTURES MAY BE USED.
SURFACE MEMBRANE CLAMP
EXISTING PIPING FOR CONNECTION (VERIFY
DIAMETER IN FIELD PRIOR TO INSTALLATION)
STRAINER SHALL BE COMPLIANT WITH 2010 ADA
STANDARDS
SHEET FLOORING FINISH; SEE FINISH SCHEDULE
WIDE ANCHOR FLANGE
FLOOR DRAIN BODY
EXISTING PLYWOOD SUBSTRATE TO REMAIN
NEW 1/4" SANDED FACE PLYWOOD
UNDERLAYMENT; APA TRADEMARKED PLYWOOD
OF GRADE C-C PLUGGED OR BETTER (OR
EQUIVALENT); THIS PRODUCT SHALL MEET
ASTM F1482 - 15 REQUIREMENTS.
FEATHERED SELF-LEVELING COMPOUND AS
NEEDED BETWEEN PLYWOOD LAYERS.
NEW SUBFLOORINGEXST SUBFLOORING
NEW 1/2" PLYWOOD SUBSTRATE
NEW 1/2" SANDED FACE PLYWOOD UNDERLAYMENT; APA
TRADEMARKED PLYWOOD OF GRADE C-C PLUGGED OR
BETTER (OR EQUIVALENT); THIS PRODUCT SHALL MEET
ASTM F1482 - 15 REQUIREMENTS.
FEATHERED SELF-LEVELING COMPOUND AS NEEDED
BETWEEN PLYWOOD LAYERS.
NEW SUBFLOORINGEXST SUBFLOORING
1ST FLOOR
0' - 0"
NOTE: REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE, PLACE ACCESSORIES
BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS RESPONSIBLE FOR DOCUMENTING AND
REINSTALLING IN CORRECT MOUNTING HEIGHTS AND LOCATIONS.
EXISTING COUNTERTOPS, SINKS AND FAUCETS TO REMAIN. PROTECT
AS REQUIRED DURING ALL CONSTRUCTION ACTIVITY, TYPICAL.
NEW FLASH COVE BASE; SEE FINISH PLAN AND
SCHEDULE.
NEW PAINT THROUGHOUT EXPOSED GYPSUM
WALLBOARD SURFACES; SEE FINISH PLAN AND
SCHEDULE
Existing Tile Height 5' - 10"
Ceiling Height 9' - 0"
1ST FLOOR
0' - 0"
EXISTING 2X12 WOOD JOIST TO
REMAIN - SEE A4 / A-401 FOR
JOIST REPAIR
NEW 1/2" PLYWOOD C/D
EXTERIOR GRADE T & G
SUBSTRATE (TOILET ROOMS,
SHOWER ROOMS, AND
BATHROOMS).
FEATHERED SELF-LEVELING
COMPOUND AS NEEDED
BETWEEN PLYWOOD LAYERS
NEW 1/2" EXTERIOR GRADE T &
G. SANDED FACE PLYWOOD
UNDERLAYMENT; APA
TRADEMARKED PLYWOOD OF
GRADE C-C PLUGGED OR
BETTER (OR EQUIVALENT).
SHEET FLOORING, SEE A-720
FOR FINISH SELECTIONS AND
SEAM LOCATIONS
EXISTING PLYWOOD
SUBSTRATE TO REMAIN
(LAVATORY AREAS)
NEW 1/4" EXTERIOR
GRADE T & G. SANDED
FACE PLYWOOD
UNDERLAYMENT; APA
TRADEMARKED
PLYWOOD OF GRADE C-
C PLUGGED OR BETTER
(OR EQUIVALENT).
FEATHERED SELF-
LEVELING COMPOUND
AS NEEDED BETWEEN
PLYWOOD LAYERS
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2018 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
TEL. 864.235.0405 FAX 864.233.4027
GREENVILLE, SOUTH CAROLINA 29601
110 WEST NORTH STREET SUITE 300
/2
/2
:5
:1
A
M
C
U s e rs
\c a it ly n s h a w
\D o c u m e n ts \A rc h
G re e n v il le
C o u n ty C a m p S p e a rh e a d
P le a s a n t R id g e c a it s h a w ls p
.c o m .r v t
3702-186030
23 October 2018
CHS
DO
ENLARGED
PLANS AND
DETAILS
A-401
Pleasant Ridge - Flooring Repair and Waterproofing
Permit & Construction
Camp Spearhead
1/4" = 1'-0" C1
DOUBLE POD TOILET/BATHING AREAS
1/4" = 1'-0" A1
TYPICAL WET WALLS IN TOILET/BATHING AREAS
3" = 1'-0" D4
FLOORING TRANSITION @ SHOWER
1 1/2" = 1'-0" A4
WALL SECTION - NEW CONDITION @ FLOOR
3" = 1'-0" C4
DETAIL FOR FLASH COVE BASE AT WET WALL
3" = 1'-0" E4
FLOOR DRAIN DETAIL FOR NEW AND EXISTING SUBFLOORING
1/4" = 1'-0" B1
TYPICAL VANITY AREA WALL IN TOILET/BATHING AREAS
ALTERNATES
ALTERNATE A: FRP SHALL BE INSTALLED
ON WET WALL BEHIND TOILETS IN SINGLE
TOILET ROOMS ABOVE FLASH-COVED
FLOORING. REINSTALL EXISTING GRAB
BARS IN ORIGINAL LOCATIONS
SEE DETAIL A4 / A-401.
FINISH SELECTIONS ON A-720.
3" = 1'-0" D5
OLD TO NEW SUBFLOOR TRANSITION
5.5
EXISTING 2X12 FLOOR JOISTS TO REMAIN
REINFORCE DAMAGED EXISTING 2X12 WOOD
JOISTS BY SISTERING NEW PRESSURE
TREATED 2X12 WOOD JOISTS ON EITHER SIDE
SECURED NEW JOISTS TO EXISTING JOIST
WITH TIMBERLOK SCREWS (TWO ROWS @ 16"
O.C.).
PROVIDE SIMPSON STRONG TIES FOR
JOIST CONNECTION (VERIFY CONDITION
IN THE FIELD (TYPICAL AT ALL END
LOCATIONS).
2x12 WOOD JOIST @ 16" O.C.
TIMBERLOK SCREWS (TWO ROWS @ 16" O.C.)
DAMAGED EXISTING 2x12 WOOD JOIST
NEW SUBFLOOR AND FLOORING SYSTEM, SEE B1
/ A-401 FOR SUBFLOOR DETAILS. SEE SHEET
A-720 FOR FINISH PLAN AND SCHEDULE.
PROVIDE SIMPSON STRONG TIES FOR JOIST
CONNECTION (VERIFY CONDITION IN THE FIELD)
(TYPICAL AT ALL END LOCATIONS)
1. PRIOR TO INSTALLATION AND FABRICATION, CONTRACTOR SHALL COORDINATE
WITH ARCHITECT AND INTERIOR DESIGNER TO REVIEW ALL FLOOR PATTERNS,
FINISHES AND DOCUMENTATION INFORMATION.
2. PRIOR TO PAINTING, PAINTING CONTRACTOR SHALL SUBMIT TO
ARCHITECT/INTERIOR DESIGNER EACH PAINT COLOR FINISH ON A 8 1/2" X 11" SHEET
OF CHIPBOARD FOR PRELIMINARY APPROVAL. FOR FINAL APPROVAL BY OWNER AND
ARCHITECT PRIOR TO PAINTING, THE PAINTING CONTRACTOR SHALL VERIFY PAINT
COLOR MATCH OF EXISTING WALL FINISH.
3. INSTALLERS OF EACH FINISH MATERIAL SHALL INSPECT BOTH THE SUBSTRATE
AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. INSTALLER SHALL NOT
PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN AN
ACCEPTABLE MANNER TO ALL PARTIES AND MEET ALL MANUFACTURER'S
REQUIREMENTS.
4. ALL INTERIOR FINISHES SHALL COMPLY WITH SECTION 803 OF RESTRICTIONS OF
COMBUSTIBLE MATERIALS OF THE INTERNATIONAL BUILDING CODE. ALL INTERIOR
FINISHES SHALL BE CLASS B OR BETTER.
5. THE INTENT IS TO PROVIDE A COMPLETE FINISHED INTERIOR WHETHER OR NOT
SPECIFICALLY INDICATED. ITEMS SHALL BE FINISHED AND/OR PAINTED AS DIRECTED
BY DESIGNER, WHETHER OR NOT SPECIFICALLY SCHEDULED OR INDICATED ON
DRAWINGS.
6. INSTALL TRANSITION STRIP AT THRESHOLD WHERE DIFFERING FLOORING
MATERIALS ABUTT, UNLESS OTHERWISE NOTED. COORDINATE COLOR/FINISH WITH
DESIGNER.
7. ALL FLOOR FINISH CHANGES / TRANSITIONS SHALL OCCUR AT THE CENTER LINE
OF CLOSED DOORS.
8. FLOOR PATTERN TO CONTINUE UNDER ALL OPEN WOODWORK/ WORKSURFACES.
9. PRIOR TO ORDERING, SUB-CONTRACTORS FOR FLOORING, PAINTING, AND
MILLWORK SHALL SUBMIT TO ARCHITECT / INTERIOR DESIGNER AN 8" X 8" SAMPLE OF
EACH MATERIAL SPECIFIED FOR FINAL APPROVAL.
10. IF ANY DISCREPANCIES OR OMISSIONS ARE NOTED IN THESE DRAWINGS,
CONTACT INTERIOR DESIGNER OR ARCHITECT PRIOR TO ORDERING OR
COMMENCING WORK.
11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK LEAD TIMES ON
FINISHES IN ORDER TO AVOID DELAYING WORK.
ROOM FINISH PLAN SHEET NOTES
1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.
2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.
3. SEE SHEETS A-720 FOR FINISH FLOORING, TRANSITIONS, PATTERNS AND WALL
PROTECTION.
4. SEE SHEET A-720 FOR FINISH SCHEDULE.
5. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES THAT ARE
REMOVED SHALL BE CLEANED AND REINSTALLED USING NEW INSTALLATION
KITS.
6. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING
FINISH SHALL REMAIN AS IS.
7. REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE,
PLACE ACCESSORIES BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS
RESPONSIBLE FOR DOCUMENTING AND REUSING MOUNTING HEIGHTS AND
LOCATIONS.
GENERAL NOTES
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2018 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
TEL. 864.235.0405 FAX 864.233.4027
GREENVILLE, SOUTH CAROLINA 29601
110 WEST NORTH STREET SUITE 300
/2
/2
:5
:1
A
M
C
U s e rs
\c a it ly n s h a w
\D o c u m e n ts \A rc h
G re e n v il le
C o u n ty C a m p S p e a rh e a d
P le a s a n t R id g e c a it s h a w ls p
.c o m .r v t
3702-186030
23 October 2018
CHS
DO
ENLARGED
PLANS AND
DETAILS
A-402
Pleasant Ridge - Flooring Repair and Waterproofing
Permit & Construction
Camp Spearhead
1 1/2" = 1'-0" A1
TYPICAL FLOOR JOIST REPAIR AS REQUIRED
A5
3D PERSPECTIVE - FLOOR JOIST REPAIR
ALTERNATES
ALTERNATE A: FRP SHALL BE INSTALLED
ON WET WALL BEHIND TOILETS IN SINGLE
TOILET ROOMS ABOVE FLASH-COVED
FLOORING. REINSTALL EXISTING GRAB
BARS IN ORIGINAL LOCATIONS
SEE DETAIL A4 / A-401.
FINISH SELECTIONS ON A-720.
/D
WH
W /D
5 6
E E
F F
5.5
LAVATORY
PNT-1
SV-1
SV-1
SHOWER
PNT-1, FRP-1
SV-1
SV-1
SHOWER
PNT-1, FRP-1
SV-1
SV-1
TOILET
PNT-1
SV-1
SV-1
TOILET
PNT-1
SV-1
SV-1
STORAGE /
LAUNDRY
x
BATHROOM
PNT-1, FRP-1
SV-1
SV-1
LAVATORY
PNT-1
SV-1
SV-1
SHOWER
PNT-1, FRP-1
SV-1
SV-1
SHOWER
PNT-1, FRP-1
SV-1
SV-1
TOILET
PNT-1
SV-1
SV-1
TOILET
PNT-1
SV-1
SV-1
STORAGE /
LAUNDRY
x
BATHROOM
PNT-1, FRP-1
SV-1
SV-1
FRP-1
FRP-1
FRP-1
FRP-1
ALT. A
FRP-1
ALT. A
FRP-1
ALT. A
FRP-1
ALT. A
FRP-1
F R
P -1
F R
P -1
F R
P -1
F R
P -1
F R
P -1
F R
P -1
F R
P -1
F R
P -1
NOT IN
SCOPE
D5
A-401
1. PRIOR TO INSTALLATION AND FABRICATION, CONTRACTOR SHALL COORDINATE
WITH ARCHITECT AND INTERIOR DESIGNER TO REVIEW ALL FLOOR PATTERNS,
FINISHES AND DOCUMENTATION INFORMATION.
2. PRIOR TO PAINTING, PAINTING CONTRACTOR SHALL SUBMIT TO
ARCHITECT/INTERIOR DESIGNER EACH PAINT COLOR FINISH ON A 8 1/2" X 11" SHEET
OF CHIPBOARD FOR PRELIMINARY APPROVAL. FOR FINAL APPROVAL BY OWNER AND
ARCHITECT PRIOR TO PAINTING, THE PAINTING CONTRACTOR SHALL VERIFY PAINT
COLOR MATCH OF EXISTING WALL FINISH.
3. INSTALLERS OF EACH FINISH MATERIAL SHALL INSPECT BOTH THE SUBSTRATE
AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. INSTALLER SHALL NOT
PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN AN
ACCEPTABLE MANNER TO ALL PARTIES AND MEET ALL MANUFACTURER'S
REQUIREMENTS.
4. ALL INTERIOR FINISHES SHALL COMPLY WITH SECTION 803 OF RESTRICTIONS OF
COMBUSTIBLE MATERIALS OF THE INTERNATIONAL BUILDING CODE. ALL INTERIOR
FINISHES SHALL BE CLASS B OR BETTER.
5. THE INTENT IS TO PROVIDE A COMPLETE FINISHED INTERIOR WHETHER OR NOT
SPECIFICALLY INDICATED. ITEMS SHALL BE FINISHED AND/OR PAINTED AS DIRECTED
BY DESIGNER, WHETHER OR NOT SPECIFICALLY SCHEDULED OR INDICATED ON
DRAWINGS.
6. INSTALL TRANSITION STRIP AT THRESHOLD WHERE DIFFERING FLOORING
MATERIALS ABUTT, UNLESS OTHERWISE NOTED. COORDINATE COLOR/FINISH WITH
DESIGNER.
7. ALL FLOOR FINISH CHANGES / TRANSITIONS SHALL OCCUR AT THE CENTER LINE
OF CLOSED DOORS.
8. FLOOR PATTERN TO CONTINUE UNDER ALL OPEN WOODWORK/ WORKSURFACES.
9. PRIOR TO ORDERING, SUB-CONTRACTORS FOR FLOORING, PAINTING, AND
MILLWORK SHALL SUBMIT TO ARCHITECT / INTERIOR DESIGNER AN 8" X 8" SAMPLE OF
EACH MATERIAL SPECIFIED FOR FINAL APPROVAL.
10. IF ANY DISCREPANCIES OR OMISSIONS ARE NOTED IN THESE DRAWINGS,
CONTACT INTERIOR DESIGNER OR ARCHITECT PRIOR TO ORDERING OR
COMMENCING WORK.
11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK LEAD TIMES ON
FINISHES IN ORDER TO AVOID DELAYING WORK.
ROOM FINISH PLAN SHEET NOTES
FLOOR FINISH DIRECTION TAG
1. USE TS-1 AT TRANSITION FROM SV-1 TO EXISTING WOOD.
2. FRP-1 SHALL BE INSTALLED BEHIND TOILETS IF ALTERNATE B IS ACCEPTED.
ROOM FINISH REMARKS
CHECKED BY:
DRAWN BY:
DATE:
PROJECT:
REVISIONS:
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
A
2 3 4 5 6
B
C
D
E
COPYRIGHT 2018 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
FROM LS3P ASSOCIATES LTD.
WWW.LS3P.COM
TEL. 864.235.0405 FAX 864.233.4027
GREENVILLE, SOUTH CAROLINA 29601
110 WEST NORTH STREET SUITE 300
/2
/2
:5
:1
A
M
C
U s e rs
\c a it ly n s h a w
\D o c u m e n ts \A rc h
G re e n v il le
C o u n ty C a m p S p e a rh e a d
P le a s a n t R id g e c a it s h a w ls p
.c o m .r v t
3702-186030
23 October 2018
Author
Checker
FINISH PLAN
A-720
Pleasant Ridge - Flooring Repair and Waterproofing
Permit & Construction
Camp Spearhead
1/4" = 1'-0" C1
DOUBLE POD TOILET/BATHING AREAS - TYPICAL FINISH PLAN
ROOM FINISH SCHEDULE
ROOM WALL
FINISH BASE FLOORING REMARKSNUMBER NAME
1ST FLOOR
100 LAVATORY PNT-1 SV-1 SV-1 1
102 TOILET PNT-1 SV-1 SV-1 2
103 TOILET PNT-1 SV-1 SV-1 2
104 SHOWER PNT-1,
FRP-1
SV-1 SV-1
105 SHOWER PNT-1,
FRP-1
SV-1 SV-1
200 LAVATORY PNT-1 SV-1 SV-1 1
201 BATHROOM PNT-1,
FRP-1
SV-1 SV-1
202 TOILET PNT-1 SV-1 SV-1 2
203 TOILET PNT-1 SV-1 SV-1 2
204 SHOWER PNT-1,
FRP-1
SV-1 SV-1
205 SHOWER PNT-1,
FRP-1
SV-1 SV-1
300 LAVATORY PNT-1 SV-1 SV-1 1
301 BATHROOM PNT-1,
FRP-1
SV-1 SV-1
302 TOILET PNT-1 SV-1 SV-1 2
303 TOILET PNT-1 SV-1 SV-1 2
304 SHOWER PNT-1,
FRP-1
SV-1 SV-1
305 SHOWER PNT-1,
FRP-1
SV-1 SV-1
400 LAVATORY PNT-1 SV-1 SV-1 1
401 BATHROOM
402 TOILET PNT-1 SV-1 SV-1 2
403 TOILET PNT-1 SV-1 SV-1 2
404 SHOWER PNT-1,
FRP-1
SV-1 SV-1
405 SHOWER PNT-1,
FRP-1
SV-1 SV-1
ROOM FINISH LEGEND
MATERIAL
CODE DESCRIPTION MANUFACTURER
PRODUCT NAME
AND NUMBER
STYLE /
PATTERN FINISH COLOR SIZE INSTALLATION FORMAT / COMMENTS REP CONTACT INFO NOTES
DIVISION 9 FINISHES - FLOORS
SV-1 SHEET VINYL FLOORING ALTRO AQUARIUS AQI2006 OTTER 6'-7"W X
66'L
INCLUDE 6"H FLASH COVING WITH COVE CAP IN ALL
AREAS. SEE C4/A-401. SV-1 SHALL RUN 2" UNDER LIP OF
PREFAB SHOWER AND SEALED WITH ALTROMASTIC 100.
EDDIE RUMSEY
404.275.3031
ALL SEAMS SHALL BE HEAT WELDED. USE TWO PART EPOXY ADHESIVE THROUGHOUT FOR FLOOR
INSTALLATION AND A SURFACE CLAMPING MEMBRANE FLOOR DRAIN (BY JR SMITH OR EQUAL) IN ALL EXISTING DRAIN LOCATIONS. IF SV-1 SPEC. DOES NOT ALLOW FOR BID SITUATION TO OCCUR, SUBMIT
EQUAL PRODUCT TO INTERIOR DESIGNER FOR CONSIDERATION.
DIVISION 9 FINISHES - WALLS
FRP-1 FIBERGLASS REINFORCED PLASTIC
PANEL
PANOLAM CLASS "C"
GENERAL
PURPOSE
EMBOSSED SILVER 4'W X
12'L
INSTALL WITH REQUIRED TRIM PIECES TO HEIGHT OF
PREFAB SHOWER UNIT IN SHOWER ROOMS AND TO
5'-6"H AFF IN TOILET ROOMS IF ALTERNATE B IS TAKEN.
BETTY GERULA
704-614-3985
INTENT OF LARGE PIECES IS TO CUT THE 12' LENGTH IN HALF TO CREATE TWO 6' LENGTHS TO
ACCOMMODATE HEIGHT REQUIRED IN SHOWER ROOMS.
PNT-1 PAINT SHERWIN
WILLIAMS
PROMAR 200 ZERO
VOC INTERIOR
LATEX SEMI-GLOSS
B31-2600
SERIES
SEMI-GLOSS SW6109
HOPSACK
RUSS HANSEN
(980)-207-9410
USE FOR WALL PAINT WITHIN SCOPE OF WORK.
DIVISION 10 SPECIALTIES
TS-1 TRANSITION STRIP JOHNSONITE SLIMLINE
TRANSITION
DEPENDS
ON FINAL
FINISHED
FLOOR
HEIGHTS
283 TOAST USE AT SV-1 TO EXISTING WOOD FLOORING
TRANSITIONS ONLY.
EMMA MALTBA
910.988.4167
ALTERNATES
ALTERNATE A: FRP SHALL BE INSTALLED
ON WET WALL BEHIND TOILETS IN SINGLE
TOILET ROOMS ABOVE FLASH-COVED
FLOORING. REINSTALL EXISTING GRAB
BARS IN ORIGINAL LOCATIONS
SEE DETAIL A4 / A-401.
FINISH SELECTIONS ON A-720.
| Sheets |
| A-101 - FLOOR PLAN & PROJECT INFORMATION |
| A-401 - ENLARGED PLANS AND DETAILS |
| A-402 - ENLARGED PLANS AND DETAILS |
| A-720 - FINISH PLAN |
| AD-101 - DEMOLITION PLANS AND DETAILS |
| G-001 - PROJECT INFORMATION SHEET |