Summary

This is an architectural drawing set for flooring repair and waterproofing work at Pleasant Ridge, a County of Greenville facility located at 4232 Highway 11, Marietta, SC 29661. The project encompasses flooring and waterproofing improvements to wet rooms (bathrooms, shower rooms, and toilet rooms) across eight cabins containing 24 shower spaces—16 shower-only rooms and 8 full bathrooms with toilets and sinks. The scope of work includes demolition of existing ceramic tile flooring and wall tile, removal and storage of plumbing fixtures for reuse, repair or replacement of damaged wooden floor joists using sistering techniques with pressure-treated lumber, installation of new plywood subflooring with self-leveling compound, and installation of new sheet vinyl flooring (Altro Aquarius) with six-inch flash cove integration and floor drains. New moisture-resistant gypsum wallboard and fiberglass reinforced plastic (FRP) finish will be applied to wet walls in shower and toilet rooms, with existing fixtures to be reinstalled with new installation kits. The drawings indicate existing conditions and new construction details across multiple sheets (A-101 Floor Plan, AD-101 Demolition Plans, A-401 and A-402 Enlarged Plans, and A-720 Finish Plan), with specific dimensions, material specifications, and construction notes provided throughout.

The project documents specify Altro Aquarius sheet flooring in Otter color with heat-welded seams, Panolam fiberglass reinforced plastic panels for wet wall protection, and Sherwin Williams Promar 200 paint finish. An alternate (Alternate A) provides for FRP installation on walls behind toilets in single toilet rooms. Contractors are required to provide unit cost pricing per square foot for removing and replacing damaged subfloor, coordinate with the architect and interior designer prior to material ordering and installation, submit finish samples for approval, and maintain proper documentation of existing fixture locations for reinstallation. All existing plumbing fixtures, toilet accessories, and fixtures must be cleaned and reinstalled using new installation kits, with the contractor responsible for any damages occurring during construction at no cost to the owner.

View the file

Other files

File Type Posted
Pleasant_Ridge_Flooring_Repair_&_Waterproofing.pdf PDF
COG_Sub_W9_.pdf PDF
Sample_Services_Agreement.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROOM NAME

150 SF

SUBSYSTEM

TYPICAL DIMENSION INDICATOR

DETAIL/PLAN KEY

SECTION KEYS

DIRECTION OF

SECTION

ELEVATION KEY

REVISION INDICATION

REVISION NUMBER

AREA REVISED

DOOR NUMBER

GLASS TYPE

DRAWING

TITLE

DRAWING NAME

DRAWING SCALE

ENLARGED DETAIL INDICATOR

DIRECTION OF SECTION

TERMINATION OF SECTION

DRAWING LOCATION ON SHEET GRID

DETAIL LOCATION ON SHEET GRID

SHEET IDENTIFIER FOR

LOCATION OF DETAIL

BUILDING SECTION LOCATION

ON SHEET GRID

SHEET IDENTIFIER FOR

LOCATION OF SECTION

WALL SECTION LOCATION ON SHEET

GRID

SHEET IDENTIFIER FOR

LOCATION OF SECTION

DETAIL LOCATION ON SHEET GRID

SHEET IDENTIFIER FOR

LOCATION OF DETAIL

COLUMN GRID REFERENCE

TERMINATION OF SECTION

DRAWING NAME

DRAWING SCALE

DRAWING LOCATION ON SHEET GRID

SHEET NUMBER WHERE DETAIL IS REFERENCED

SHEET NUMBER WHERE DETAIL IS DRAWN

A

A1

PLAN

1/8" = 1'-0"

NTS

A1

PLAN

A101

A1

201A

CENTERLINE

9 1/2"

FLOOR ELEVATION

ROOM NAME & NUMBER

A

ELEVATION LOCATION ON SHEET GRID

SHEET IDENTIFIER FOR

LOCATION OF ELEVATION

DIRECTION OF ELEVATION

A-201

A1

W1

A-201

A1

A-201

A1

A-201

A1

A-201

A1

1ST FLOOR

0'-0"

EARTH

POROUS FILL

(STONE OR GRAVEL)

ROCK

LIGHTWEIGHT CONCRETE

(OR CONCRETE FILL)

STRUCTURAL CONCRETE

(CAST IN PLACE, ETC.)

BRICK

(COMMON OR FACE)

CONC. MASONRY UNITS

(C.M.U.)

PLASTER, CEMENT,

SAND, GROUT

STEEL, IRON

ALUMINUM

WOOD (FINISH)

WOOD (ROUGH)

WOOD BLOCKING

PLAN AND SECTION

PLYWOOD

SPRAY-ON

FIREPROOFING

BATT/LOOSE FILL

INSULATION

EXTRUDED POLYSTYRENE

ACOUSTICAL TILE

GYPSUM WALLBOARD

CARPET AND PAD

BRICK

CERAMIC TILE

CONCRETE / PLASTER /

STUCCO

GLASS

SHINGLES/SIDING

MATERIAL LEGEND (NOT ALL MATERIALS APPLICABLE)

ELEVATION

POD C

POD B

C4

C3

C2

C1

B4

B3

B2

B1

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2018 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

TEL. 864.235.0405 FAX 864.233.4027

GREENVILLE, SOUTH CAROLINA 29601

110 WEST NORTH STREET SUITE 300

/2

/2

:5

:5

A

M

C

U s e rs

\c a it ly n s h a w

\D o c u m e n ts \A rc h

G re e n v il le

C o u n ty C a m p S p e a rh e a d

P le a s a n t R id g e c a it s h a w ls p

.c o m .r v t

3702-186030

23 October 2018

CHS

DO

PROJECT

INFORMATION

SHEET

G-001

Pleasant Ridge - Flooring Repair and Waterproofing

Permit & Construction

Camp Spearhead

GRAPHIC SYMBOL LEGEND

SHEET INDEX

SHEET NO. SHEET NAME SHT REV NO. SHT REV DATE REVISION DESCRIPTION

G-001 PROJECT INFORMATION SHEET

GENERAL

ARCHITECTURAL

LS3P

110 WEST NORTH STREET, SUITE 300

GREENVILLE, NC 29601

tel: 864.235.0405 email: deanoang@ls3p.com

Pleasant Ridge - Flooring Repair and Waterproofing

3702-186030

Permit & Construction4232 SC-11 Marietta, SC 29661

23 October 2018

SHEET NO. SHEET NAME SHT REV NO. SHT REV DATE REVISION DESCRIPTION

A-101 FLOOR PLAN & PROJECT INFORMATION

AD-101 DEMOLITION PLANS AND DETAILS

A-401 ENLARGED PLANS AND DETAILS

A-402 ENLARGED PLANS AND DETAILS

A-720 FINISH PLAN

TOJ TOP OF JOIST

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOS TOP OF SLAB

TOW TOP OF WALL

TRTD TREATED

TV TELEVISION

TYP TYPICAL

UL UNDERWRITERS

LABORATORIES

UNO UNLESS NOTED OTHERWISE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

W WEST, WIDE

W/ WITH

W/O WITHOUT

W/W WALL TO WALL

WC WATER CLOSET

WD WOOD

WP WORKING POINT,

WATERPROOFING

WR WATER REPELLENT

WT WEIGHT

WWF WELDED WIRE FABRIC

YD YARD

NOM NOMINAL

NON

COMB

NON-COMBUSTIBLE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OPP OPPOSITE

OPT OPTION(AL)

PCF POUNDS PER CUBIC FEET

PLAM PLASTIC LAMINATE

PLF POUNDS PER LINEAR FEET

PLYWD PLYWOOD

PNL PANEL

PR PAIR

PREFAB PREFABRICATED

PREFIN PREFINISH

PRKG PARKING

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, POST-TENSIONED,

PRE-TREATED

PVC POLYVINYL CHLORIDE

(PLASTIC)

QTR QUARTER

QTY QUANTITY

R RADIUS, RISER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFRIGERATOR, REFERENCE

REQD REQUIRED

RL ROOF LEADER

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

S SOUTH

SC SOLID CORE

SD STORM DRAIN

SECT SECTION

SF SQUARE FEET

SIM SIMILAR

SPEC SPECIFICATION

SPKR SPEAKER

SQ SQUARE

SS STAINLESS STEEL

STD STANDARD

STOR STORAGE

SUSP SUSPENDED

SYS SYSTEM

T TREAD

TEL TELEPHONE

TEMP TEMPORARY

TFF TOP OF FINISH FLOOR

THK THICKNESS

THRU THROUGH

TO TOP OF

TOB TOP OF BEAM

TOC TOP OF CONCRETE, CURB

TOF TOP OF FOOTING

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF EL FINISH FLOOR ELEVATION

FHC FIRE HOSE CABINET

FIN FLR FINISHED FLOOR

FLR FLOOR, FILLER

FOC FACE OF CURB

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF SLAB

FOW FACE OF WALL

FT FOOT, FEET

FTG FOOTING

FURN FURNISH, FURNITURE

GA GAGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

HC HANDICAP

HD HEAVY DUTY

HDWD HARDWOOD

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING, VENTILATION & AIR

CONDITIONING

ID INSIDE DIAMETER

INCL INCLUDE(D), (ING)

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

JAN CLO JANITOR CLOSET

KIT KITCHEN

KO KNOCKOUT

LAB LABORATORY

LAM LAMINATE

LAU LAUNDRY

LAV LAVATORY

LF LINEAR FEET

LVR LOUVER

MAINT MAINTENANCE

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MEZZ MEZZANINE

MFG MANUFACTURING

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MR MOISTURE RESISTANT

MTD MOUNTED

MTG MOUNTING

MTL METAL

N NORTH

NIC NOT IN CONTRACT

A/C AIR CONDITION(ING)

ADMIN ADMINISTRATION

AFF ABOVE FINISHED FLOOR

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE(LY)

ARCH ARCHITECT(URAL)

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIOVISUAL

BITUM BITUMINOUS

BL BUILDING LINE

BLDG BUILDING

BN BULL NOSE

BOS BOTTOM OF STEEL

BOT BOTTOM

CAB CABINET

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG HT CEILING HEIGHT

CLO CLOSET

CLR CLEAR(ANCE)

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONF CONFERENCE

CONT CONTINUE. CONTINUOUS

CORR CORRIDOR

CU FT CUBIC FOOT

CU YD CUBIC YARD

DEMO DEMOLISH

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DIV DIVISION

DS DOWNSPOUT

E EAST

EA EACH

EIFS EXTERIOR INSULATION &

FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC(AL)

ELEV ELEVATOR

ENCL ENCLOSE(D)

EOS EDGE OF SLAB

EQ EQUAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EXIST EXISTING

EXP JT EXPANSION JOINT

EXT EXTERIOR

F/F FACE TO FACE

FD FLOOR DRAIN

ABBREVIATIONS

AREA AND VICINITY MAP

EXISTING BUILDING ALTERATION - LEVEL 01 PER IBC 2015

ARCHITECTURAL

No. Description Date

WH

W /D

WH

W /D

WH

W /D

WH

W /D

E E

F F

G G

16'-1 5/8" 20'-0" 20'-0" 20'-0" 16'-1 5/8"

A A

B B

'-0

'-0

'-0

C C

D D

5.5

5.5

1'-6 3/4" 1'-6 3/4"

/8

8'-8"

32'-1 5/8"

8'-8"

32'-1 5/8"

A-401

C1

/8

/4

AD-101

C3

TYPICAL POD LAYOUT - POD "C" SHOWN

CABIN C1

(CABIN B1)

CABIN C4(CABIN B4)

CABIN C3

(CABIN B3)

CABIN C2

(CABIN B2)

A-720

C1

LAVATORY

SHOWER

SHOWER

TOILET

TOILET

LAVATORY

SHOWER

SHOWER

TOILET

TOILET

BATHROOM

LAVATORY

SHOWER

SHOWER

TOILET

TOILET

BATHROOM

LAVATORY

SHOWER

SHOWER

TOILET

TOILET

BATHROOM

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

ALL DIMENSIONS SHALL BE VERIFIED BY THE

CONTRACTOR IN THE FIELD PRIOR TO WORK

BEGINNING. CONTRACTOR SHALL BE

RESPONSIBLE FOR MINOR ADJUSTMENTS IN

THE FIELD. MAJOR DISCREPANCIES SHALL

BE BROUGHT TO THE OWNERS &

ARCHITECTS ATTENTION.

NOT IN

SCOPE

BATHROOM

1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.

2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.

3. SEE SHEETS A-720 FOR FINISH FLOORING, TRANSITIONS, PATTERNS AND WALL

PROTECTION.

4. SEE SHEET A-720 FOR FINISH SCHEDULE.

5. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES THAT ARE

REMOVED SHALL BE CLEANED AND REINSTALLED USING NEW INSTALLATION

KITS.

6. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING

FINISH SHALL REMAIN AS IS.

7. REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE,

PLACE ACCESSORIES BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS

RESPONSIBLE FOR DOCUMENTING AND REUSING MOUNTING HEIGHTS AND

LOCATIONS.

GENERAL NOTES

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2018 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

TEL. 864.235.0405 FAX 864.233.4027

GREENVILLE, SOUTH CAROLINA 29601

110 WEST NORTH STREET SUITE 300

/2

/2

:5

:0

A

M

C

U s e rs

\c a it ly n s h a w

\D o c u m e n ts \A rc h

G re e n v il le

C o u n ty C a m p S p e a rh e a d

P le a s a n t R id g e c a it s h a w ls p

.c o m .r v t

3702-186030

23 October 2018

CHS

DO

FLOOR PLAN &

PROJECT

INFORMATION

A-101

Pleasant Ridge - Flooring Repair and Waterproofing

Permit & Construction

Camp Spearhead

N

TRUE

NORTH

N

1/8" = 1'-0" A1

TYPICAL POD FLOOR PLAN

/D

WH

W /D

WH

W /D

WH

W /D

E E

F F

5.5

5.5

DEMO EXISTING FLOOR DRAINS.

REMOVE EXISTING PREFAB SHOWER

UNITS, CURTAIN RODS, GRAB BARS,

AND SHOWER PLUMBING FIXTURES

AND STORE FOR REUSE. CONTRACTOR

TO PROVIDE STORAGE LOCATION.

DEMO EXISTING FLOOR DRAINS.

REMOVE EXISTING PREFAB SHOWER

UNITS, CURTAIN RODS, GRAB BARS, AND

SHOWER PLUMBING FIXTURES AND STORE

FOR REUSE. CONTRACTOR TO PROVIDE

STORAGE LOCATION.

REMOVE EXISTING TOILETS AND STORE

FOR REUSE. CONTRACTOR TO PROVIDE

STORAGE LOCATION.

B4

AD-101

EXISTING COUNTERTOPS, SINKS AND

FAUCETS TO REMAIN. PROTECT AS

REQUIRED DURING ALL

CONSTRUCTION ACTIVITY, TYPICAL.

EXISTING COUNTERTOPS, SINKS AND

FAUCETS TO REMAIN. PROTECT AS

REQUIRED DURING ALL CONSTRUCTION

ACTIVITY, TYPICAL.

NOTE: CONTACT OWNER / ARCHITECT IF ANY FIXTURES, WALLS, DOORS, OR CASEWORK APPEAR TO HAVE WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION. CONTACT OWNER / ARCHITECT IF STRUCTURAL INTEGRITY APPEARS TO BE COMPROMISED AS A RESULT OF WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION.

ANY DAMAGES THAT OCCUR DURING CONSTRUCTION WILL BE REPAIRED AND/OR REPLACED AT NO COST TO THE

OWNER.

A1

AD-101

CABIN B3, C3 CABIN B2, C2

WALL TILE AND GRAB BARS IN TOILET

ROOMS; SEE ALTERNATE A.

DEMO WALL TILE IN SHOWER

ROOMS.

REMOVE EXISTING PREFAB SHOWER

UNITS, CURTAIN RODS, GRAB BARS,

AND SHOWER PLUMBING FIXTURES

AND STORE FOR REUSE. CONTRACTOR

TO PROVIDE STORAGE LOCATION.

REMOVE EXISTING PREFAB SHOWER

UNITS, CURTAIN RODS, GRAB BARS, AND

SHOWER PLUMBING FIXTURES AND STORE

FOR REUSE. CONTRACTOR TO PROVIDE

STORAGE LOCATION.

LAVATORY

LAVATORY

NOT IN

SCOPE

SHOWER

SHOWER

TOILET

TOILET

BATHROOM

BATHROOM

TOILET

TOILET

SHOWER

SHOWER

DEMO WALL TILE IN SHOWER

ROOMS.

WALL TILE AND GRAB BARS IN TOILET

ROOMS; SEE ALTERNATE A.

DEMO EXISTING FLOOR DRAINS.

DEMO ALL CERAMIC TILE FLOORING

AND CERAMIC TILE BASE

THROUGHOUT TOILETING / BATHING /

VANITY AREAS.

DEMO ALL CERAMIC TILE FLOORING

AND CERAMIC TILE BASE

THROUGHOUT TOILETING / BATHING /

VANITY AREAS.

REMOVE EXISTING TOILETS AND

STORE FOR REUSE. CONTRACTOR TO

PROVIDE STORAGE LOCATION.

DEMO SUBFLOOR IN TOILETING/BATHING ROOMS

D E

M O

S U

B F

L O

O R

I N

T O

IL

E

T

IN

G /B

A T

H

IN

G R

O O

M S

PROVIDE UNIT COST PER SF ON REMOVING AND

REPLACING DAMAGED SUBFLOOR.

D5

A-401

1ST FLOOR

0' - 0"

REMOVE DAMAGED SPRAY FOAM

INSULATION AS NEEDED; INSULATION

WITHOUT WATER OR CONSTRUCTION

DAMAGE SHALL REMAIN

REMOVE TILE FLOORING AND TILE BASE (ALL

BATHING / TOILETING ROOMS)

REMOVE PLYWOOD SUBFLOOR THROUGHOUT

SHOWER AND TOILET ROOMS

EXISTING 2X12 WOOD JOISTS SHALL REMAIN

SEE A4 / A-401 FOR SCOPE OF WORK IF JOIST

IS DAMAGED.

NOTE: CONTACT OWNER / ARCHITECT IF ANY FIXTURES, WALLS, DOORS, OR CASEWORK APPEAR TO HAVE WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION. CONTACT OWNER / ARCHITECT IF STRUCTURAL INTEGRITY APPEARS TO BE COMPROMISED AS A RESULT OF WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION.

ANY DAMAGES THAT OCCUR DURING CONSTRUCTION WILL BE REPAIRED AND/OR REPLACED AT NO COST TO THE

OWNER.

REMOVE TILE AND GYPSUM WALL BOARD @ SHOWER

ROOM. EXISTING DRYWALL IN SHOWER ROOMS

WITHOUT TILE SHALL REMAIN.

WALL TILE IN TOILET ROOMS: SEE ALTERNATE A.

EXISTING STRUCTURAL INSULATION WALL (EXTERIOR

WALLS)

EXISTING 2X6 STUD FRAMING IN "DOUBLE" CABIN

UNITS

INSPECT ALL SILL PLATES AND BASE OF WALL STUDS FOR

WATER OR OTHER DAMAGE. REPORT ANY DAMAGE

IMMEDIATELY TO THE ARCHITECT.

1ST FLOOR

0' - 0"

WALL TILE AND GRAB BARS IN TOILET ROOMS;

SEE ALTERNATE A.

REMOVE EXISTING TOILETS AND STORE

FOR REUSE. CONTRACTOR TO PROVIDE

STORAGE LOCATION.

REMOVE EXISTING PREFAB SHOWER

UNITS, CURTAIN RODS, GRAB BARS,

AND SHOWER PLUMBING FIXTURES

AND STORE FOR REUSE. CONTRACTOR

TO PROVIDE STORAGE LOCATION.

EXISTING PREFAB SHOWER UNITS,

CURTAIN RODS, GRAB BARS, AND SHOWER

PLUMBING FIXTURES SHALL BE REMOVED

FOR REUSE IN EXISTING LOCATION.

REMOVE WALL TILE IN ALL SHOWER

ROOMS. Existing Tile Height

5' - 10"

Ceiling Height 9' - 0"

1. CONTRACTOR TO PERFORM DEMOLITION WORK AS REQUIRED PER WORK

SEQUENCE.

2. DEMOLITION DRAWINGS ARE INTENDED TO SHOW GENERAL AREAS OF

DEMOLITION AS WELL AS GENERAL EXISTING CONDITIONS. THEY DO NOT

SHOW ALL WORK WHICH MAY BE NECESSARY. COMPARE WITH DRAWINGS

INDICATING NEW CONSTRUCTION.

3. EXISTING WORK TO REMAIN SHALL BE TEMPORARILY SECURED, BRACED AND

STABILIZED UNTIL PERMANENT CONSTRUCTION IS IN PLACE.

4. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES SHALL BE

PROPERLY STORED FOR REUSE FOLLOWING THE COMPLETION OF FINISH

INSTALLATION. STORAGE LOCATION TO BE PROVIDED BY CONTRACTOR.

5. VERIFY FIELD CONDITIONS PRIOR TO START OF DEMOLITION/CONSTRUCTION

AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

6. VERIFY THAT CONSTRUCTION INDICATED FOR REMOVAL IS NOT LOAD

BEARING OR IS ADEQUATELY SHORED AS REQUIRED.

7. ERECT BARRICADES, FENCES OR OTHER SECURABLE MEANS TO PREVENT

UNAUTHORIZED ACCESS INTO CONSTRUCTION ZONES.

8. DO NOT ALLOW MATERIAL AND DEBRIS GENERATED BY DEMOLITION

ACTIVITIES TO ACCUMULATE ON THE JOB SITE. REMOVE DAILY AND DISPOSE

OF IN A LEGAL MANNER. NO ON-SITE SALE OR BURNING OF REMOVED ITEMS

IS PERMITTED.

9. THE CONTRACTOR MUST MAINTAIN ADEQUATE SUPPORT INSULATION,

WATERPROOFING, EMERGENCY LIGHTING, SECURITY, ALARMS, ETC. FOR ALL

OR PART OF ITEMS WHICH ARE TO REMAIN.

10. PREPARE AND PATCH SURFACES THAT RECEIVE NEW FINISHES AS REQUIRED

BY REMOVING OR RELOCATING DEVICES, WIRING OR OTHER

APPURTENANCES NO LONGER APPROPRIATE FOR THE NEW USE OF THE

ROOM.

11. MAINTAIN EXISTING FINISHES, OPERATIONAL CHARACTERISTICS, AND

APPEARANCE OF ITEMS SCHEDULED TO REMAIN OR BE REUSED.

12. ANY DAMAGE TO THE EXISTING STRUCTURE CAUSED BY THE CONTRACTOR

WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO COST TO THE

OWNER.

DEMOLITION PLAN SHEET NOTES

1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.

2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.

3. SEE SHEETS A-720 FOR FINISH FLOORING, TRANSITIONS, PATTERNS AND WALL

PROTECTION.

4. SEE SHEET A-720 FOR FINISH SCHEDULE.

5. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES THAT ARE

REMOVED SHALL BE CLEANED AND REINSTALLED USING NEW INSTALLATION

KITS.

6. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING

FINISH SHALL REMAIN AS IS.

7. REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE,

PLACE ACCESSORIES BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS

RESPONSIBLE FOR DOCUMENTING AND REUSING MOUNTING HEIGHTS AND

LOCATIONS.

GENERAL NOTES

E E

F F

5.5

5.5

NOTE: CONTACT OWNER / ARCHITECT IF ANY FIXTURES, WALLS, DOORS, OR CASEWORK APPEAR TO HAVE WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION. CONTACT OWNER / ARCHITECT IF STRUCTURAL INTEGRITY APPEARS TO BE COMPROMISED AS A RESULT OF WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION.

ANY DAMAGES THAT OCCUR DURING CONSTRUCTION WILL BE REPAIRED AND/OR REPLACED AT NO COST TO THE

OWNER.

CABIN B3, C3 CABIN B2, C2

NOT IN

SCOPE

5'-1 1/2"

4'-8"

2'-7 3/8" 6'-9"

/4

/4

/8

/8

/8

/8

/8

5'-1 1/4"2'-7 3/8"

4'-8"

6'-9"

ALL DIMENSIONS SHALL BE VERIFIED BY THE

CONTRACTOR IN THE FIELD PRIOR TO WORK

BEGINNING. CONTRACTOR SHALL BE

RESPONSIBLE FOR MINOR ADJUSTMENTS IN

THE FIELD. MAJOR DISCREPANCIES SHALL

BE BROUGHT TO THE OWNERS &

ARCHITECTS ATTENTION.

6'-9" 6'-9"8'-1 1/2" 8'-1 3/4"

EXISTING FLOOR DRAINS

(TYPICAL)

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2018 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

TEL. 864.235.0405 FAX 864.233.4027

GREENVILLE, SOUTH CAROLINA 29601

110 WEST NORTH STREET SUITE 300

/2

/2

:5

:1

A

M

C

U s e rs

\c a it ly n s h a w

\D o c u m e n ts \A rc h

G re e n v il le

C o u n ty C a m p S p e a rh e a d

P le a s a n t R id g e c a it s h a w ls p

.c o m .r v t

3702-186030

23 October 2018

Author

Checker

DEMOLITION

PLANS AND

DETAILS

AD-101

Pleasant Ridge - Flooring Repair and Waterproofing

Permit & Construction

Camp Spearhead

1/4" = 1'-0" C3

DEMOLITION PLAN: DOUBLE POD TOILET/BATHING AREA

TYPICAL DOUBLE CABIN

1 1/2" = 1'-0" B4

WALL SECTION - EXST CONDITION @ FLOOR

1/4" = 1'-0"

A1

TYPICAL WET WALLS IN TOILET/BATHING AREAS - DEMOLITION

ALTERNATES

ALTERNATE A: DEMO CERAMIC TILE ON

WALLS IN TOILET ROOMS. REMOVE GRAB

BARS IN TOILET ROOMS AND STORE FOR

REUSE. CONTRACTOR TO PROVIDE

STORAGE LOCATION.

1/4" = 1'-0" C1

EXISTING FLOOR PLAN: DOUBLE POD TOILET/BATHING AREA

TYPICAL DOUBLE CABIN

/D

WH

W /D

1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.

2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.

3. SEE SHEETS A-720 FOR FINISH FLOORING, TRANSITIONS, PATTERNS AND WALL

PROTECTION.

4. SEE SHEET A-720 FOR FINISH SCHEDULE.

5. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES THAT ARE

REMOVED SHALL BE CLEANED AND REINSTALLED USING NEW INSTALLATION

KITS.

6. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING

FINISH SHALL REMAIN AS IS.

7. REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE,

PLACE ACCESSORIES BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS

RESPONSIBLE FOR DOCUMENTING AND REUSING MOUNTING HEIGHTS AND

LOCATIONS.

GENERAL NOTES

5 6

E E

F F

5.5

NEW SHEET VINYL FLOORING.

A1

A-401

INSTALL NEW 7" FLOOR DRAINS IN ORIGINAL LOCATIONS IN

CONJUNCTION WITH NEW SHEET VINYL FLOORING PER

MANUFACTURER'S INSTALLATION INSTRUCTIONS. SEE E4 /

A-401. CONNECT TO EXISTING PIPING. CONTRACTOR IS

RESPONSIBLE FOR DOCUMENTING AND INSTALLING NEW

FLOOR DRAINS IN ORIGINAL LOCATIONS (TYPICAL).

A-402

A1

LAVATORY

SHOWER

SHOWER

TOILET

TOILET

STORAGE /

LAUNDRY

BATHROOM

LAVATORY

SHOWER

SHOWER

TOILET

TOILET

STORAGE /

LAUNDRY

BATHROOM

D4

A-401

USE SELF-LEVELING COMPOUND TO LEVEL THE SUBFLOOR AS

NEEDED BEFORE FINAL UNDERLAYMENT PLYWOOD LAYER IS

INSTALLED SEE D4 / A-401.

SHOWER ROOMS, TOILET ROOMS, AND BATHROOMS TO

RECEIVE NEW SUBFLOOR, SEE D4 / A-401.

SEE FINISH PLAN AND SCHEDULE FOR

TRANSITION SPECIFICATION.

A-401B1

NOT IN

SCOPE

CLEAN AND REINSTALL NEW TOILET AND SHOWER

FIXTURES WITH NEW INSTALLATION KITS, TYPICAL.

D4

A-401

D5

A-401

1ST FLOOR

0' - 0"

FLASH COVE BASE.

REINSTALL GRAB BARS IN ORIGINAL LOCATIONS OVER NEW

DRYWALL AND FINISH.

A-401

D4 A-401

E4

REINSTALL PLUMBING FIXTURES IN ORIGINAL LOCATIONS OVER

NEW FLOORING.

NEW FRP APPLIED TO NEW MOISTURE-RESISTANT GYPSUM WALL

BOARD TO EXTEND FROM COVED BASE TO HEIGHT OF SHOWER.

SEE FINISH PLAN AND SCHEDULE FOR FRP SPECIFICATION.

Existing Tile Height 5' - 10"

Ceiling Height 9' - 0"

TOILET ROOM WALL TILE TO REMAIN; SEE ALTERNATE A.

SHEET FLOORING TO RUN UNDER ENTRY EDGE OF

SHOWER FOR 2" MINIMUM.

NEW 1/2" PLYWOOD C/D EXTERIOR GRADE T & G

SUBSTRATE.

NEW 1/2" EXTERIOR GRADE T & G. SANDED FACE

PLYWOOD UNDERLAYMENT; APA TRADEMARKED

PLYWOOD OF GRADE C-C PLUGGED OR BETTER

(OR EQUIVALENT).

CLEAN AND REINSTALL EXISTING TOILET AND SHOWER

FIXTURES WITH NEW INSTALLATION KITS, TYPICAL.

CLEAR MILDEW-RESISTANT SILICONE CAULK JOINT

WHERE SHOWER FIXTURE EDGE MEETS SHEET

FLOORING (SEE A-720).

FEATHERED SELF-LEVELING COMPOUND AS

NEEDED BETWEEN PLYWOOD LAYERS

1ST FLOOR

0' - 0"

NEW CLOSED CELL SPRAY FOAM

INSULATION AS NEEDED; INSULATION

SHALL BE APPLIED 4" THICK TO ENSURE

PROPER THERMAL R-VALUE

ALTRO AQUARIUS SHEET FLOORING

WITH 6" FLASH COVE INTEGRATION.

NEW 1/2" PLYWOOD C/D EXTERIOR

GRADE T & G SUBSTRATE.

EXISTING 2X12 WOOD JOISTS SHALL

REMAIN

NOTE: ALL MATERIALS USED SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. SAMPLES OF ALL FINISH SELECTIONS SHALL BE CONFIRMED BY OWNER / ARCHITECT PRIOR TO INSTALLATION.

FLOORING MUST BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

REINFORCE DAMAGED EXISTING 2X12

WOOD JOISTS BY SISTERING NEW

PRESSURE TREATED 2X12 WOOD JOISTS

ON EITHER SIDE SECURED NEW JOISTS

TO EXISTING JOIST WITH TIMBERLOK

SCREWS (TWO ROWS @ 16" O.C.).

NEW 5/8" MOISTURE-RESISTANT GYPSUM

WALL BOARD (UNPAINTED AND

UNPRIMED) ON WET WALLS UP TO

HEIGHT OF SHOWER.

NEW 1/2" EXTERIOR GRADE T & G.

SANDED FACE PLYWOOD

UNDERLAYMENT; APA TRADEMARKED

PLYWOOD OF GRADE C-C PLUGGED OR

BETTER (OR EQUIVALENT).

FIBERGLASS REINFORCED PLASTIC (FRP)

FINISH APPLIED TO GYPSUM WALL BOARD

SURFACE ON WET WALLS UP TO HEIGHT

OF SHOWER. USE CRANE ADVANCED

POLYMER ADHESIVE (OR EQUIVALENT).

A-401

C4

EXISTING PLUMBING FIXTURES IN

CONTACT WITH FLOORING WILL BE

REINSTALLED WITH NEW INSTALLATION

KIT. THIS APPLIES TO ALL SHOWER

UNITS AND TOILETS.

FEATHERED SELF-LEVELING

COMPOUND AS NEEDED BETWEEN

PLYWOOD LAYERS.

NEW WALL FINISHES IN SHOWER

ROOMS.

TOILET TILE WALL TO REMAIN IN BASE

BID, SEE ALTERNATE A FOR UPGRADE

OPTION.

PROVIDE SIMPSON STRONG TIES FOR

JOIST CONNECTION (VERIFY CONDITION

IN THE FIELD (TYPICAL AT LOCATIONS).IF EXISTING WOOD JOIST IS

COMPLETELY UNSALVAGEABLE,

REPLACE AS NEEDED.

1. PRIOR TO INSTALLATION AND FABRICATION, CONTRACTOR SHALL COORDINATE

WITH ARCHITECT AND INTERIOR DESIGNER TO REVIEW ALL FLOOR PATTERNS,

FINISHES AND DOCUMENTATION INFORMATION.

2. PRIOR TO PAINTING, PAINTING CONTRACTOR SHALL SUBMIT TO

ARCHITECT/INTERIOR DESIGNER EACH PAINT COLOR FINISH ON A 8 1/2" X 11" SHEET

OF CHIPBOARD FOR PRELIMINARY APPROVAL. FOR FINAL APPROVAL BY OWNER AND

ARCHITECT PRIOR TO PAINTING, THE PAINTING CONTRACTOR SHALL VERIFY PAINT

COLOR MATCH OF EXISTING WALL FINISH.

3. INSTALLERS OF EACH FINISH MATERIAL SHALL INSPECT BOTH THE SUBSTRATE

AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. INSTALLER SHALL NOT

PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN AN

ACCEPTABLE MANNER TO ALL PARTIES AND MEET ALL MANUFACTURER'S

REQUIREMENTS.

4. ALL INTERIOR FINISHES SHALL COMPLY WITH SECTION 803 OF RESTRICTIONS OF

COMBUSTIBLE MATERIALS OF THE INTERNATIONAL BUILDING CODE. ALL INTERIOR

FINISHES SHALL BE CLASS B OR BETTER.

5. THE INTENT IS TO PROVIDE A COMPLETE FINISHED INTERIOR WHETHER OR NOT

SPECIFICALLY INDICATED. ITEMS SHALL BE FINISHED AND/OR PAINTED AS DIRECTED

BY DESIGNER, WHETHER OR NOT SPECIFICALLY SCHEDULED OR INDICATED ON

DRAWINGS.

6. INSTALL TRANSITION STRIP AT THRESHOLD WHERE DIFFERING FLOORING

MATERIALS ABUTT, UNLESS OTHERWISE NOTED. COORDINATE COLOR/FINISH WITH

DESIGNER.

7. ALL FLOOR FINISH CHANGES / TRANSITIONS SHALL OCCUR AT THE CENTER LINE

OF CLOSED DOORS.

8. FLOOR PATTERN TO CONTINUE UNDER ALL OPEN WOODWORK/ WORKSURFACES.

9. PRIOR TO ORDERING, SUB-CONTRACTORS FOR FLOORING, PAINTING, AND

MILLWORK SHALL SUBMIT TO ARCHITECT / INTERIOR DESIGNER AN 8" X 8" SAMPLE OF

EACH MATERIAL SPECIFIED FOR FINAL APPROVAL.

10. IF ANY DISCREPANCIES OR OMISSIONS ARE NOTED IN THESE DRAWINGS,

CONTACT INTERIOR DESIGNER OR ARCHITECT PRIOR TO ORDERING OR

COMMENCING WORK.

11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK LEAD TIMES ON

FINISHES IN ORDER TO AVOID DELAYING WORK.

ROOM FINISH PLAN SHEET NOTES

1ST FLOOR

0' - 0"

NEW 5/8" MOISTURE-RESISTANT GYPSUM WALL

BOARD (UNPAINTED AND UNPRIMED) ON WET

WALLS.

WHERE SCHEDULED, FIBERGLASS REINFORCED

PLASTIC (FRP) FINISH SHALL BE APPLIED TO GYPSUM

WALL BOARD SURFACE ON WET WALLS UP TO

HEIGHT OF SHOWER. USE CRANE ADVANCED

POLYMER ADHESIVE (OR EQUIVALENT).

EXISTING WALL STRUCTURE TO REMAIN.

FLASH COVE CAP STRIP

NEW 1/2" PLYWOOD C/D EXTERIOR GRADE T &

G SUBSTRATE.

NEW 1/2" EXTERIOR GRADE T & G. SANDED FACE

PLYWOOD UNDERLAYMENT; APA TRADEMARKED

PLYWOOD OF GRADE C-C PLUGGED OR BETTER (OR

EQUIVALENT). THIS PRODUCT SHALL MEET ASTM

F1482 - 15 REQUIREMENTS.

1 1/2" COVE FORMER CONTINUOUS AROUND

PERIMETER WHERE FLOORING APPLICATION

MEETS VERTICAL WALLSV-1 FLOORING WITH 6" FLASH COVE INTEGRATION.

FEATHERED SELF-LEVELING COMPOUND AS NEEDED

BETWEEN PLYWOOD LAYERS.

F L

A S

H C

O V

E

1ST FLOOR

0' - 0"

NOTE: ALL MATERIALS AND FIXTURES USED SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

FLOOR DRAIN BASIS OF DESIGN: MIFAB F1100-FC 7" DIAMETER FLOOR DRAIN WITH SURFACE MEMBRANE

CLAMP. EQUIVALENT FIXTURES MAY BE USED.

SURFACE MEMBRANE CLAMP

EXISTING PIPING FOR CONNECTION (VERIFY

DIAMETER IN FIELD PRIOR TO INSTALLATION)

STRAINER SHALL BE COMPLIANT WITH 2010 ADA

STANDARDS

SHEET FLOORING FINISH; SEE FINISH SCHEDULE

WIDE ANCHOR FLANGE

FLOOR DRAIN BODY

EXISTING PLYWOOD SUBSTRATE TO REMAIN

NEW 1/4" SANDED FACE PLYWOOD

UNDERLAYMENT; APA TRADEMARKED PLYWOOD

OF GRADE C-C PLUGGED OR BETTER (OR

EQUIVALENT); THIS PRODUCT SHALL MEET

ASTM F1482 - 15 REQUIREMENTS.

FEATHERED SELF-LEVELING COMPOUND AS

NEEDED BETWEEN PLYWOOD LAYERS.

NEW SUBFLOORINGEXST SUBFLOORING

NEW 1/2" PLYWOOD SUBSTRATE

NEW 1/2" SANDED FACE PLYWOOD UNDERLAYMENT; APA

TRADEMARKED PLYWOOD OF GRADE C-C PLUGGED OR

BETTER (OR EQUIVALENT); THIS PRODUCT SHALL MEET

ASTM F1482 - 15 REQUIREMENTS.

FEATHERED SELF-LEVELING COMPOUND AS NEEDED

BETWEEN PLYWOOD LAYERS.

NEW SUBFLOORINGEXST SUBFLOORING

1ST FLOOR

0' - 0"

NOTE: REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE, PLACE ACCESSORIES

BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS RESPONSIBLE FOR DOCUMENTING AND

REINSTALLING IN CORRECT MOUNTING HEIGHTS AND LOCATIONS.

EXISTING COUNTERTOPS, SINKS AND FAUCETS TO REMAIN. PROTECT

AS REQUIRED DURING ALL CONSTRUCTION ACTIVITY, TYPICAL.

NEW FLASH COVE BASE; SEE FINISH PLAN AND

SCHEDULE.

NEW PAINT THROUGHOUT EXPOSED GYPSUM

WALLBOARD SURFACES; SEE FINISH PLAN AND

SCHEDULE

Existing Tile Height 5' - 10"

Ceiling Height 9' - 0"

1ST FLOOR

0' - 0"

EXISTING 2X12 WOOD JOIST TO

REMAIN - SEE A4 / A-401 FOR

JOIST REPAIR

NEW 1/2" PLYWOOD C/D

EXTERIOR GRADE T & G

SUBSTRATE (TOILET ROOMS,

SHOWER ROOMS, AND

BATHROOMS).

FEATHERED SELF-LEVELING

COMPOUND AS NEEDED

BETWEEN PLYWOOD LAYERS

NEW 1/2" EXTERIOR GRADE T &

G. SANDED FACE PLYWOOD

UNDERLAYMENT; APA

TRADEMARKED PLYWOOD OF

GRADE C-C PLUGGED OR

BETTER (OR EQUIVALENT).

SHEET FLOORING, SEE A-720

FOR FINISH SELECTIONS AND

SEAM LOCATIONS

EXISTING PLYWOOD

SUBSTRATE TO REMAIN

(LAVATORY AREAS)

NEW 1/4" EXTERIOR

GRADE T & G. SANDED

FACE PLYWOOD

UNDERLAYMENT; APA

TRADEMARKED

PLYWOOD OF GRADE C-

C PLUGGED OR BETTER

(OR EQUIVALENT).

FEATHERED SELF-

LEVELING COMPOUND

AS NEEDED BETWEEN

PLYWOOD LAYERS

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2018 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

TEL. 864.235.0405 FAX 864.233.4027

GREENVILLE, SOUTH CAROLINA 29601

110 WEST NORTH STREET SUITE 300

/2

/2

:5

:1

A

M

C

U s e rs

\c a it ly n s h a w

\D o c u m e n ts \A rc h

G re e n v il le

C o u n ty C a m p S p e a rh e a d

P le a s a n t R id g e c a it s h a w ls p

.c o m .r v t

3702-186030

23 October 2018

CHS

DO

ENLARGED

PLANS AND

DETAILS

A-401

Pleasant Ridge - Flooring Repair and Waterproofing

Permit & Construction

Camp Spearhead

1/4" = 1'-0" C1

DOUBLE POD TOILET/BATHING AREAS

1/4" = 1'-0" A1

TYPICAL WET WALLS IN TOILET/BATHING AREAS

3" = 1'-0" D4

FLOORING TRANSITION @ SHOWER

1 1/2" = 1'-0" A4

WALL SECTION - NEW CONDITION @ FLOOR

3" = 1'-0" C4

DETAIL FOR FLASH COVE BASE AT WET WALL

3" = 1'-0" E4

FLOOR DRAIN DETAIL FOR NEW AND EXISTING SUBFLOORING

1/4" = 1'-0" B1

TYPICAL VANITY AREA WALL IN TOILET/BATHING AREAS

ALTERNATES

ALTERNATE A: FRP SHALL BE INSTALLED

ON WET WALL BEHIND TOILETS IN SINGLE

TOILET ROOMS ABOVE FLASH-COVED

FLOORING. REINSTALL EXISTING GRAB

BARS IN ORIGINAL LOCATIONS

SEE DETAIL A4 / A-401.

FINISH SELECTIONS ON A-720.

3" = 1'-0" D5

OLD TO NEW SUBFLOOR TRANSITION

5.5

EXISTING 2X12 FLOOR JOISTS TO REMAIN

REINFORCE DAMAGED EXISTING 2X12 WOOD

JOISTS BY SISTERING NEW PRESSURE

TREATED 2X12 WOOD JOISTS ON EITHER SIDE

SECURED NEW JOISTS TO EXISTING JOIST

WITH TIMBERLOK SCREWS (TWO ROWS @ 16"

O.C.).

PROVIDE SIMPSON STRONG TIES FOR

JOIST CONNECTION (VERIFY CONDITION

IN THE FIELD (TYPICAL AT ALL END

LOCATIONS).

2x12 WOOD JOIST @ 16" O.C.

TIMBERLOK SCREWS (TWO ROWS @ 16" O.C.)

DAMAGED EXISTING 2x12 WOOD JOIST

NEW SUBFLOOR AND FLOORING SYSTEM, SEE B1

/ A-401 FOR SUBFLOOR DETAILS. SEE SHEET

A-720 FOR FINISH PLAN AND SCHEDULE.

PROVIDE SIMPSON STRONG TIES FOR JOIST

CONNECTION (VERIFY CONDITION IN THE FIELD)

(TYPICAL AT ALL END LOCATIONS)

1. PRIOR TO INSTALLATION AND FABRICATION, CONTRACTOR SHALL COORDINATE

WITH ARCHITECT AND INTERIOR DESIGNER TO REVIEW ALL FLOOR PATTERNS,

FINISHES AND DOCUMENTATION INFORMATION.

2. PRIOR TO PAINTING, PAINTING CONTRACTOR SHALL SUBMIT TO

ARCHITECT/INTERIOR DESIGNER EACH PAINT COLOR FINISH ON A 8 1/2" X 11" SHEET

OF CHIPBOARD FOR PRELIMINARY APPROVAL. FOR FINAL APPROVAL BY OWNER AND

ARCHITECT PRIOR TO PAINTING, THE PAINTING CONTRACTOR SHALL VERIFY PAINT

COLOR MATCH OF EXISTING WALL FINISH.

3. INSTALLERS OF EACH FINISH MATERIAL SHALL INSPECT BOTH THE SUBSTRATE

AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. INSTALLER SHALL NOT

PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN AN

ACCEPTABLE MANNER TO ALL PARTIES AND MEET ALL MANUFACTURER'S

REQUIREMENTS.

4. ALL INTERIOR FINISHES SHALL COMPLY WITH SECTION 803 OF RESTRICTIONS OF

COMBUSTIBLE MATERIALS OF THE INTERNATIONAL BUILDING CODE. ALL INTERIOR

FINISHES SHALL BE CLASS B OR BETTER.

5. THE INTENT IS TO PROVIDE A COMPLETE FINISHED INTERIOR WHETHER OR NOT

SPECIFICALLY INDICATED. ITEMS SHALL BE FINISHED AND/OR PAINTED AS DIRECTED

BY DESIGNER, WHETHER OR NOT SPECIFICALLY SCHEDULED OR INDICATED ON

DRAWINGS.

6. INSTALL TRANSITION STRIP AT THRESHOLD WHERE DIFFERING FLOORING

MATERIALS ABUTT, UNLESS OTHERWISE NOTED. COORDINATE COLOR/FINISH WITH

DESIGNER.

7. ALL FLOOR FINISH CHANGES / TRANSITIONS SHALL OCCUR AT THE CENTER LINE

OF CLOSED DOORS.

8. FLOOR PATTERN TO CONTINUE UNDER ALL OPEN WOODWORK/ WORKSURFACES.

9. PRIOR TO ORDERING, SUB-CONTRACTORS FOR FLOORING, PAINTING, AND

MILLWORK SHALL SUBMIT TO ARCHITECT / INTERIOR DESIGNER AN 8" X 8" SAMPLE OF

EACH MATERIAL SPECIFIED FOR FINAL APPROVAL.

10. IF ANY DISCREPANCIES OR OMISSIONS ARE NOTED IN THESE DRAWINGS,

CONTACT INTERIOR DESIGNER OR ARCHITECT PRIOR TO ORDERING OR

COMMENCING WORK.

11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK LEAD TIMES ON

FINISHES IN ORDER TO AVOID DELAYING WORK.

ROOM FINISH PLAN SHEET NOTES

1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.

2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.

3. SEE SHEETS A-720 FOR FINISH FLOORING, TRANSITIONS, PATTERNS AND WALL

PROTECTION.

4. SEE SHEET A-720 FOR FINISH SCHEDULE.

5. ALL EXISTING PLUMBING FIXTURES AND TOILET ACCESSORIES THAT ARE

REMOVED SHALL BE CLEANED AND REINSTALLED USING NEW INSTALLATION

KITS.

6. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING

FINISH SHALL REMAIN AS IS.

7. REUSE ALL EXISTING TOILET ACCESSORIES. AFTER PAINTING IS COMPLETE,

PLACE ACCESSORIES BACK IN THEIR ORIGINAL LOCATION. CONTRACTOR IS

RESPONSIBLE FOR DOCUMENTING AND REUSING MOUNTING HEIGHTS AND

LOCATIONS.

GENERAL NOTES

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2018 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

TEL. 864.235.0405 FAX 864.233.4027

GREENVILLE, SOUTH CAROLINA 29601

110 WEST NORTH STREET SUITE 300

/2

/2

:5

:1

A

M

C

U s e rs

\c a it ly n s h a w

\D o c u m e n ts \A rc h

G re e n v il le

C o u n ty C a m p S p e a rh e a d

P le a s a n t R id g e c a it s h a w ls p

.c o m .r v t

3702-186030

23 October 2018

CHS

DO

ENLARGED

PLANS AND

DETAILS

A-402

Pleasant Ridge - Flooring Repair and Waterproofing

Permit & Construction

Camp Spearhead

1 1/2" = 1'-0" A1

TYPICAL FLOOR JOIST REPAIR AS REQUIRED

A5

3D PERSPECTIVE - FLOOR JOIST REPAIR

ALTERNATES

ALTERNATE A: FRP SHALL BE INSTALLED

ON WET WALL BEHIND TOILETS IN SINGLE

TOILET ROOMS ABOVE FLASH-COVED

FLOORING. REINSTALL EXISTING GRAB

BARS IN ORIGINAL LOCATIONS

SEE DETAIL A4 / A-401.

FINISH SELECTIONS ON A-720.

/D

WH

W /D

5 6

E E

F F

5.5

LAVATORY

PNT-1

SV-1

SV-1

SHOWER

PNT-1, FRP-1

SV-1

SV-1

SHOWER

PNT-1, FRP-1

SV-1

SV-1

TOILET

PNT-1

SV-1

SV-1

TOILET

PNT-1

SV-1

SV-1

STORAGE /

LAUNDRY

x

BATHROOM

PNT-1, FRP-1

SV-1

SV-1

LAVATORY

PNT-1

SV-1

SV-1

SHOWER

PNT-1, FRP-1

SV-1

SV-1

SHOWER

PNT-1, FRP-1

SV-1

SV-1

TOILET

PNT-1

SV-1

SV-1

TOILET

PNT-1

SV-1

SV-1

STORAGE /

LAUNDRY

x

BATHROOM

PNT-1, FRP-1

SV-1

SV-1

FRP-1

FRP-1

FRP-1

FRP-1

ALT. A

FRP-1

ALT. A

FRP-1

ALT. A

FRP-1

ALT. A

FRP-1

F R

P -1

F R

P -1

F R

P -1

F R

P -1

F R

P -1

F R

P -1

F R

P -1

F R

P -1

NOT IN

SCOPE

D5

A-401

1. PRIOR TO INSTALLATION AND FABRICATION, CONTRACTOR SHALL COORDINATE

WITH ARCHITECT AND INTERIOR DESIGNER TO REVIEW ALL FLOOR PATTERNS,

FINISHES AND DOCUMENTATION INFORMATION.

2. PRIOR TO PAINTING, PAINTING CONTRACTOR SHALL SUBMIT TO

ARCHITECT/INTERIOR DESIGNER EACH PAINT COLOR FINISH ON A 8 1/2" X 11" SHEET

OF CHIPBOARD FOR PRELIMINARY APPROVAL. FOR FINAL APPROVAL BY OWNER AND

ARCHITECT PRIOR TO PAINTING, THE PAINTING CONTRACTOR SHALL VERIFY PAINT

COLOR MATCH OF EXISTING WALL FINISH.

3. INSTALLERS OF EACH FINISH MATERIAL SHALL INSPECT BOTH THE SUBSTRATE

AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. INSTALLER SHALL NOT

PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN AN

ACCEPTABLE MANNER TO ALL PARTIES AND MEET ALL MANUFACTURER'S

REQUIREMENTS.

4. ALL INTERIOR FINISHES SHALL COMPLY WITH SECTION 803 OF RESTRICTIONS OF

COMBUSTIBLE MATERIALS OF THE INTERNATIONAL BUILDING CODE. ALL INTERIOR

FINISHES SHALL BE CLASS B OR BETTER.

5. THE INTENT IS TO PROVIDE A COMPLETE FINISHED INTERIOR WHETHER OR NOT

SPECIFICALLY INDICATED. ITEMS SHALL BE FINISHED AND/OR PAINTED AS DIRECTED

BY DESIGNER, WHETHER OR NOT SPECIFICALLY SCHEDULED OR INDICATED ON

DRAWINGS.

6. INSTALL TRANSITION STRIP AT THRESHOLD WHERE DIFFERING FLOORING

MATERIALS ABUTT, UNLESS OTHERWISE NOTED. COORDINATE COLOR/FINISH WITH

DESIGNER.

7. ALL FLOOR FINISH CHANGES / TRANSITIONS SHALL OCCUR AT THE CENTER LINE

OF CLOSED DOORS.

8. FLOOR PATTERN TO CONTINUE UNDER ALL OPEN WOODWORK/ WORKSURFACES.

9. PRIOR TO ORDERING, SUB-CONTRACTORS FOR FLOORING, PAINTING, AND

MILLWORK SHALL SUBMIT TO ARCHITECT / INTERIOR DESIGNER AN 8" X 8" SAMPLE OF

EACH MATERIAL SPECIFIED FOR FINAL APPROVAL.

10. IF ANY DISCREPANCIES OR OMISSIONS ARE NOTED IN THESE DRAWINGS,

CONTACT INTERIOR DESIGNER OR ARCHITECT PRIOR TO ORDERING OR

COMMENCING WORK.

11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK LEAD TIMES ON

FINISHES IN ORDER TO AVOID DELAYING WORK.

ROOM FINISH PLAN SHEET NOTES

FLOOR FINISH DIRECTION TAG

1. USE TS-1 AT TRANSITION FROM SV-1 TO EXISTING WOOD.

2. FRP-1 SHALL BE INSTALLED BEHIND TOILETS IF ALTERNATE B IS ACCEPTED.

ROOM FINISH REMARKS

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2018 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

TEL. 864.235.0405 FAX 864.233.4027

GREENVILLE, SOUTH CAROLINA 29601

110 WEST NORTH STREET SUITE 300

/2

/2

:5

:1

A

M

C

U s e rs

\c a it ly n s h a w

\D o c u m e n ts \A rc h

G re e n v il le

C o u n ty C a m p S p e a rh e a d

P le a s a n t R id g e c a it s h a w ls p

.c o m .r v t

3702-186030

23 October 2018

Author

Checker

FINISH PLAN

A-720

Pleasant Ridge - Flooring Repair and Waterproofing

Permit & Construction

Camp Spearhead

1/4" = 1'-0" C1

DOUBLE POD TOILET/BATHING AREAS - TYPICAL FINISH PLAN

ROOM FINISH SCHEDULE

ROOM WALL

FINISH BASE FLOORING REMARKSNUMBER NAME

1ST FLOOR

100 LAVATORY PNT-1 SV-1 SV-1 1

102 TOILET PNT-1 SV-1 SV-1 2

103 TOILET PNT-1 SV-1 SV-1 2

104 SHOWER PNT-1,

FRP-1

SV-1 SV-1

105 SHOWER PNT-1,

FRP-1

SV-1 SV-1

200 LAVATORY PNT-1 SV-1 SV-1 1

201 BATHROOM PNT-1,

FRP-1

SV-1 SV-1

202 TOILET PNT-1 SV-1 SV-1 2

203 TOILET PNT-1 SV-1 SV-1 2

204 SHOWER PNT-1,

FRP-1

SV-1 SV-1

205 SHOWER PNT-1,

FRP-1

SV-1 SV-1

300 LAVATORY PNT-1 SV-1 SV-1 1

301 BATHROOM PNT-1,

FRP-1

SV-1 SV-1

302 TOILET PNT-1 SV-1 SV-1 2

303 TOILET PNT-1 SV-1 SV-1 2

304 SHOWER PNT-1,

FRP-1

SV-1 SV-1

305 SHOWER PNT-1,

FRP-1

SV-1 SV-1

400 LAVATORY PNT-1 SV-1 SV-1 1

401 BATHROOM

402 TOILET PNT-1 SV-1 SV-1 2

403 TOILET PNT-1 SV-1 SV-1 2

404 SHOWER PNT-1,

FRP-1

SV-1 SV-1

405 SHOWER PNT-1,

FRP-1

SV-1 SV-1

ROOM FINISH LEGEND

MATERIAL

CODE DESCRIPTION MANUFACTURER

PRODUCT NAME

AND NUMBER

STYLE /

PATTERN FINISH COLOR SIZE INSTALLATION FORMAT / COMMENTS REP CONTACT INFO NOTES

DIVISION 9 FINISHES - FLOORS

SV-1 SHEET VINYL FLOORING ALTRO AQUARIUS AQI2006 OTTER 6'-7"W X

66'L

INCLUDE 6"H FLASH COVING WITH COVE CAP IN ALL

AREAS. SEE C4/A-401. SV-1 SHALL RUN 2" UNDER LIP OF

PREFAB SHOWER AND SEALED WITH ALTROMASTIC 100.

EDDIE RUMSEY

404.275.3031

ALL SEAMS SHALL BE HEAT WELDED. USE TWO PART EPOXY ADHESIVE THROUGHOUT FOR FLOOR

INSTALLATION AND A SURFACE CLAMPING MEMBRANE FLOOR DRAIN (BY JR SMITH OR EQUAL) IN ALL EXISTING DRAIN LOCATIONS. IF SV-1 SPEC. DOES NOT ALLOW FOR BID SITUATION TO OCCUR, SUBMIT

EQUAL PRODUCT TO INTERIOR DESIGNER FOR CONSIDERATION.

DIVISION 9 FINISHES - WALLS

FRP-1 FIBERGLASS REINFORCED PLASTIC

PANEL

PANOLAM CLASS "C"

GENERAL

PURPOSE

EMBOSSED SILVER 4'W X

12'L

INSTALL WITH REQUIRED TRIM PIECES TO HEIGHT OF

PREFAB SHOWER UNIT IN SHOWER ROOMS AND TO

5'-6"H AFF IN TOILET ROOMS IF ALTERNATE B IS TAKEN.

BETTY GERULA

704-614-3985

INTENT OF LARGE PIECES IS TO CUT THE 12' LENGTH IN HALF TO CREATE TWO 6' LENGTHS TO

ACCOMMODATE HEIGHT REQUIRED IN SHOWER ROOMS.

PNT-1 PAINT SHERWIN

WILLIAMS

PROMAR 200 ZERO

VOC INTERIOR

LATEX SEMI-GLOSS

B31-2600

SERIES

SEMI-GLOSS SW6109

HOPSACK

RUSS HANSEN

(980)-207-9410

USE FOR WALL PAINT WITHIN SCOPE OF WORK.

DIVISION 10 SPECIALTIES

TS-1 TRANSITION STRIP JOHNSONITE SLIMLINE

TRANSITION

DEPENDS

ON FINAL

FINISHED

FLOOR

HEIGHTS

283 TOAST USE AT SV-1 TO EXISTING WOOD FLOORING

TRANSITIONS ONLY.

EMMA MALTBA

910.988.4167

ALTERNATES

ALTERNATE A: FRP SHALL BE INSTALLED

ON WET WALL BEHIND TOILETS IN SINGLE

TOILET ROOMS ABOVE FLASH-COVED

FLOORING. REINSTALL EXISTING GRAB

BARS IN ORIGINAL LOCATIONS

SEE DETAIL A4 / A-401.

FINISH SELECTIONS ON A-720.

Sheets
A-101 - FLOOR PLAN & PROJECT INFORMATION
A-401 - ENLARGED PLANS AND DETAILS
A-402 - ENLARGED PLANS AND DETAILS
A-720 - FINISH PLAN
AD-101 - DEMOLITION PLANS AND DETAILS
G-001 - PROJECT INFORMATION SHEET

File details come from the government source that posted it. Updated .