This file describes a federal contract opportunity for expansion of the Meds by Mail program at the Murfreesboro Consolidated Mail Outpatient Pharmacy facility. The solicitation number is 36C77023R0003 for project 764-21-101 to expand Meds by Mail operations. The opportunity is being offered by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15. The attached floor plan PDF provides details on the required expansion for the Meds by Mail program at the Murfreesboro, Tennessee CMOP facility to increase pharmaceutical mail order operations capacity. Responses to the solicitation are due on the date specified in the opportunity notice.

View the file

Other files

File Type Posted
36C77023R0003 0003.docx DOCX document
Pre-Bid_Questions with Photos.pdf PDF
Pre-Bid_Sign-In.pdf PDF
36C77023R0003 0002.docx DOCX document
36C77023R0003 0001.docx DOCX document
Attachment_3_Past_Performance_Questionnaire.pdf PDF
36C77023R0003_1.docx DOCX document
Specifications.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET NUMBER

WHERE DRAWN

SECTION LETTER

SECTIONS DETAILS

FT-1

TYPICAL

EQUIPMENT

NUMBER

UNIQUE I.D.

(FAN TERMINAL NO. 1)

EQUIPMENT TYPE

(FT=FAN TERMINAL)

DRAWING SYMBOLSGENERAL NOTES

B

M2.1 M3.6

M3.6

B

M2.1 M3.6

M3.6

1. VERIFY JOB SITE CONDITIONS AND DIMENSIONS BEFORE BEGINNING WORK. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING

CONDITIONS AND DIMENSIONS.

2. NO PIPING, DUCTWORK, ETC. SHALL PENETRATE STRUCTURAL MEMBERS.

3. PROVIDE MISCELLANEOUS CUTTING, PATCHING AND REPAIRING OF FINISHES, ROOF, WALLS, ETC., AS

REQUIRED TO ACCOMMODATE THE NEW WORK.

4. G.C. IS TO PATCH ANY OPENINGS IN CORRIDORS REQUIRED TO BE CONSTRUCTED TO LIMIT THE TRANSFER OF

SMOKE AND IN SMOKE BARRIERS AS REQUIRED TO MEET CODE REQUIREMENTS. SEE ARCHITECTURAL

DRAWINGS FOR LOCATIONS.

5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY EXACT LOCATION, CONFIGURATION AND ROUTING OF EXISTING SYSTEMS REQUIRED TO REMAIN IN OPERATION DURING THE PROJECT TO PREVENT DAMAGE

DURING DEMOLITION AND PHASING.

6. REMOVE ALL EXISTING EQUIPMENT, DUCTWORK AND PIPING THAT IS NOT REQUIRED FOR A WORKING

INSTALLATION.

7. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION.

8. UNLESS OTHERWISE INDICATED, INSTALL ALL SPACE THERMOSTATS AND OTHER OCCUPANT ADJUSTABLE

CONTROL DEVICES SAME HEIGHT AS ADJACENT LIGHT SWITCHES, BUT IN NO CASE HIGHER THAN 48 INCHES ABOVE FINISHED FLOOR PER ADA REQUIREMENTS. COORDINATE EXACT HEIGHT WITH ARCHITECT PRIOR TO

INSTALLATION.

9. ALL CUTTING AND PATCHING SHALL BE CLOSELY COORDINATED WITH THE G.C.

10. COORDINATE ROUTING OF PLUMBING, AND HVAC PIPING WITH DUCTWORK, LIGHTS, ARCHITECTURAL CEILING

AND STRUCTURAL ELEMENTS. PIPING SHALL RISE AND DROP, JOG OR OFFSET AS REQUIRED TO AVOID CONFLICTS. DUCTWORK SHALL TAKE PRECEDENCE OVER ALL PIPING, EXCEPT WHERE GRADE MUST BE MAINTAINED FOR DRAINAGE. REWORK OF INSTALLED WORK TO RESOLVE CONFLICTS RISING FROM LACK OF

COORDINATION SHALL NOT JUSTIFY AN INCREASE IN THE CONTRACT AMOUNT.

11. ALL DIFFUSERS ARE 4-WAY BLOW UNLESS INDICATED OTHERWISE ON THE DRAWINGS.

12. FLEXIBLE DUCTWORK IS ALLOWED ON RUNOUTS TO SUPPLY DIFFUSERS ONLY. UTILIZE ONLY ABOVE LAY-IN

ACCESSIBLE CEILINGS. DO NOT INSTALL FLEX DUCT ABOVE HARD CEILINGS OR WHERE EXPOSED. A MAXIMUM

LENGTH OF 6'-0" MAY BE USED AT EACH CONNECTION.

13. SEAL DUCTWORK AS CALLED OUT BELOW USING HARDCAST DT TAPE AND FTA-20 ADHESIVE OR HARDCAST

AFG-1402 "FOIL GRIP" PER MANUFACTURERS INSTRUCTIONS.

TYPE OF DUCT APPLY TO JOINTS

EXHAUST DUCT (ROUND OR RECT) TRANSVERSE AND LONGITUDINAL

MEDIUM VELOCITY (ROUND) TRANSVERSE AND LONGITUDINAL

MEDIUM VELOCITY (RECTANGULAR) TRANSVERSE AND LONGITUDINAL

LOW VELOCITY SUPPLY AND RETURN (RECT) TRANSVERSE AND LONGITUDINAL

LOW VELOCITY SUPPLY (ROUND) TRANSVERSE AND LONGITUDINAL

14. INSTALL BALANCE DAMPER WITH STANDOFF AND LOCKING QUADRANT IN AN ACCESSIBLE LOCATION AT EACH RUNOUT TO SUPPLY DIFFUSERS, EXHAUST GRILLES, AND RETURN GRILLES WHERE AIRFLOW IS INDICATED, OR

AS INDICATED OTHERWISE.

15. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE STOPPED BY THE TRADE MAKING THE PENETRATION. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR REQUIREMENTS.

16. DO NOT ROUTE PIPING OR DUCTWORK OVER ELECTRICAL PANELS OR EQUIPMENT. PIPING OR DUCTWORK SHALL NOT BE ROUTED THROUGH ELECTRICAL ROOMS, TELECOM ROOMS OR ELEVATOR EQUIPMENT ROOMS UNLESS SPECIFICALLY SERVING THAT ROOM. COORDINATE WITH E.C. PROVIDE WATERTIGHT DRIP PAN WITH

DRAIN TO NEAREST APPROVED RECEPTOR WHERE REQUIRED.

17. COORDINATE SIZE AND LOCATION OF ACCESS DOORS IN CONSTRUCTION REQUIRED FOR ACCESS TO

MECHANICAL EQUIPMENT WITH G.C.

18. ALL WORK IS TO CONFORM WITH APPLICABLE CODES AND STANDARDS.

19. DUCT SIZES SHOWN ARE ACTUAL INSIDE CLEAR DIMENSIONS. INCREASE SHEET METAL DIMENSIONS AS

REQUIRED TO ACCOMMODATE DUCT LINER WHERE LINER IS SPECIFIED.

20. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED AIR

DISTRIBUTION DEVICES.

21. PAINT INSIDE OF DUCTWORK BLACK ANYWHERE VISIBLE THROUGH FACE OF GRILLE OR DIFFUSER.

22. TEMPERATURE CONTROLS CONTRACTOR (T.C.C.) SHALL FURNISH AND INSTALL ALL LOW VOLTAGE WIRING AND

ASSOCIATED CONDUIT REQUIRED FOR MECHANICAL CONTROL SYSTEM. WIRING SHALL BE IN CONDUIT INSIDE WALLS, IN ROOMS WITH EXPOSED CEILINGS, AND ABOVE HARD CEILINGS. LINE VOLTAGE WIRING AND ASSOCIATED CONDUIT SHALL BE PROVIDED AND INSTALLED BY E.C. CONTROL SYSTEM SHALL BE INSTALLED

IN ACCORDANCE WITH SPECIFICATIONS.

23. COORDINATE ACCESS TO EQUIPMENT AND VALVES INSTALLED ABOVE 'HARD' CEILINGS AND IN MASONRY

CHASES WITH GENERAL CONTRACTOR. PROVIDE LOCKING ACCESS DOORS FOR INSTALLATION BY

CONTRACTOR AS REQUIRED TO SERVICE CONCEALED DAMPERS, VALVES AND EQUIPMENT. CEILING ACCESS DOORS FOR FIRE DAMPERS, SMOKE DAMPERS AND FIRE SMOKE DAMPERS FURNISHED AND INSTALLED BY

CONTRACTOR.

24. CONTRACTOR TO INSTALL TEMPORARY FILTERS OVER ALL RETURN AND EXHAUST GRILLES IN WORK AREA

DURING CONSTRUCTION.

25. THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS. REFER TO SPECIFICATIONS FOR FURTHER

INFORMATION.

26. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF TEMPORARY PARTITIONS.

27. SQUARE THROAT NOT ALLOWED ON RADIUS ELBOWS.

28. TERMINAL UNITS, MANUAL BALANCE DAMPERS, HYDRONIC AND PLUMBING VALVES, CIRCUIT SETTERS AND

OTHER ACCESSORIES REQUIRING ACCESS SHALL BE ACCESSIBLE VIA A STANDARD LADDER SO COMPONENTS MAY BE REPLACED, REPAIRED, OR UTILIZED WITHOUT THE NEED FOR EXTENSIVE CEILING REMOVAL, SCAFFOLDING OR A MAN LIFT. WHERE POSSIBLE NO MORE THAN 48” ABOVE THE FINISHED CEILING.

SHEET NUMBER

WHERE REFERENCED

SHEET NUMBER

WHERE DRAWN

DETAIL NUMBER

SHEET NUMBER

WHERE DRAWN

DETAIL NUMBER

SHEET NUMBER

WHERE REFERENCED

EQUIPMENT

CALLOUT

SHEET NUMBER

WHERE DRAWN

SECTION LETTER

REFER TO PLAN NOTES# ROOM CALLOUT

DEMOLITION PEN WEIGHT - COMPONENT MAY ALSO BE SHADED

CONNECT NEW TO EXISTING. VERIFY EXACT LOCATION.

REVISION NUMBER

EXISTING COMPONENT PEN WEIGHT

EXISTING EQUIPMENT OR MATERIAL DESIGNATION(E)

DISCONNECT FROM EXISTING. VERIFY EXACT LOCATION.

EC ELECTRICAL CONTRACTOR

GENERAL CONTRACTORGC

PC PLUMBING CONTRACTOR

MC MECHANICAL CONTRACTOR

TEMPERATURE CONTROL CONTRACTORTCC

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

HVAC & PLUMBING SYMBOL SCHEDULE

GAS COCK / GLOBE VALVE

GATE VALVE - SHUT OFF VALVE

VALVE IN DROP / VALVE IN RISER

BUTTERFLY VALVE

2-WAY / 3-WAY CONTROL VALVE (PNEUMATIC)

BALL VALVE

PLUG VALVE

STRAINER / UNION OR FLANGE CONNECTION

THERMOMETER / PRESSURE GAUGE

CHECK VALVE3 PIECE BALL VALVE / HYDRAULIC VALVE

EMERGENCY VALVE WITH FIRE LINK

2-WAY / 3-WAY CONTROL VALVE (ELECTRIC)

PRESSURE REDUCING VALVE (PRV) / WAFER CHECK VALVE

CIRCUIT SETTER - CALIBRATED BALANCE VALVE

CALIBRATED ORIFICE PLATE FLOW METER

AUTOMATIC FLOW CONTROL VALVE

SPRING HANGER / PIPE HANGER

DOUBLE CHECK BACKFLOW ASSEMBLY

REDUCED PRESSURE ZONE BACKFLOW ASSEMBLY

CAP / CAPPED OUTLET

PIPE DROP / PIPE RISE TOP CONNECTION, 45° OR 90° / BOTTOM CONNECTION, 45° OR 90°

SIDE CONNECTIONDIRECTION OF FLOW / ANCHOR

CONCENTRIC REDUCER OR INCREASER / ECCENTRIC REDUCER

DOMESTIC COLD WATER LINE (CW) ABOVE FLOOR WASTE LINE (W)

BELOW FLOOR WASTE LINE (W)DOMESTIC HOT WATER LINE (HW)

HOT WATER RECIRC LINE (HWC) PLUMBING VENT LINE (V)

F RL RAIN LEADER (RL) / OVERFLOW RAIN LEADER (ORL)FIRE PROTECTION LINE (F)

CA COMPRESSED AIR (CA) SWS

TW DOMESTIC TEMPERED WATER LINE (TW)

STORM SEWER (SWS)

FCW FILTERED COLD WATER LINE (FCW)

CD COOLING COIL CONDENSATE DRAIN LINE (CD)

WCO

CO CO

CO

FLOOR DRAIN / TRENCH DRAIN

PLUMBING FIXTURE CALLOUT

WATER HAMMER ARRESTOR - PDI SIZE

P-#

WHA#

F FLOW LINE ELEVATION

DOMESTIC HOT WATER PUMPDHWP

VTR VENT THROUGH ROOF

L

WALL CLEANOUT / END OF LINE CLEANOUT

CLEANOUT (FLOOR) / 2-WAY CLEANOUT (FLOOR)

HOSE REEL / HOSE BIBB

DI

RO

ROR

SCW

IW

G

INDUSTRIAL WASTE

NATURAL GAS LINE (G)

SOFT COLD WATER LINE (SCW)

REVERSE OSMOSIS PURE WATER SUPPLY LINE (RO)

REVERSE OSMOSIS PURE WATER RETURN LINE (ROR)

DEIONIZED PURE WATER SUPPLY (DI)

TOP / BOP TOP OF PIPE / BOTTOM OF PIPE ELEVATION ABOVE FLOOR

ROOF DRAIN / OVERFLOW ROOF DRAIN

VITRIFIED CLAY PIPE / POLYVINYL CHLORIDE PIPE

CI CAST IRON

F/S

WH-#

FILTER-SEPARATOR

WATER HEATER CALLOUT

WALL HYDRANTWH

FS FLOOR SINK

FHC FIRE HOSE CABINET

FS

FOR

FOG

FUEL SUPPLY / UNUSABLE FUEL

FUEL OIL SUPPLY / FUEL OIL RETURN

FUEL OIL GAUGE

TYP. / (TYP) TYPICAL ALL INSTANCES

NOT ALL MAY BE USED ON PROJECT

THERMOSTATIC MIXING VALVETMV

SR SUPPLY REGISTER

MAKE-UP AIR UNITMAU

HUMIDIFIERH

DP DIFFERENTIAL PRESSURE UH UNIT HEATER

COMPUTER ROOM AIR CONDITIONING UNITCRAC

ULTRAVIOLET STERILE CONDITIONERUV

24x12

24x12

24x12

RETURN DUCT RISER

SUPPLY DUCT DROP / RETURN DUCT DROP

SUPPLY DUCT RISER

FLEXIBLE DUCT

TURNING VANES

(UP)DUCT SEC., POSITIVE PRESSURE-FIRST SIZE IS TOP DIM.(TYP.)

(DOWN) DUCT SECTION, POSITIVE PRESSURE

(UP) DUCT SECTION, NEGATIVE PRESSURE

R

24x12

18x12

BALANCING DAMPER W/ MANUAL LOCKING QUADRANT

SIDE WALL SUPPLY REGISTER

(DOWN) DUCT SECTION, NEGATIVE PRESSURE

DUCT SIZE, FIRST FIGURE IS SIDE SHOWN-CLEAR INSIDE DIM.

DUCT CHANGE OF ELEVATION RISE(R) DROP(D)

FLEXIBLE CONNECTION

BALANCING DAMPER W/ MOTORIZED LOCKING QUADRANT

T

TH

H ELECTRIC OR DDC THERMOSTAT (TSTAT)

FIRE DAMPER IN WALLFD

SD SMOKE DAMPER

PNEUMATIC THERMOSTATPNEUMATIC HUMIDISTAT

FD FIRE DAMPER IN FLOOR

ELECTRIC OR DDC HUMIDISTAT (HSTAT)

T

M

H

TEMPERATURE SENSOR

MOTOR

HUMIDITY SENSOR

R RADIATION DAMPER

COMBINATION FIRE/SMOKE DAMPER IN WALLFSD

FSD COMBINATION FIRE/SMOKE DAMPER IN FLOOR

OPPOSED BLADE DAMPEROBD

TOP OF DUCT ELEVATION ABOVE FLOOR

BOD

TOD

FTU / FCU

SF SUPPLY AIR FAN

FAN POWERED TERMINAL UNIT / FAN COIL UNIT

ROOFTOP UNIT / AIR HANDLING UNITRTU / AHU

F FURNACE

SA / OA SUPPLY AIR / OUTSIDE AIR

RETURN AIR / EXHAUST AIRRA / EA

DH DUCT HEATER

BOTTOM OF DUCT ELEVATION ABOVE FLOOR

BOS BOTTOM OF STEEL EF / RG EXHAUST FAN / RETURN GRILLE

VAV VARIABLE AIR VOLUME UNIT

CVR CONSTANT VOLUME REHEAT UNIT

V V R VARIABLE VOLUME REHEAT UNIT

VARIABLE VOLUME VARIABLE TEMPERATUREV V T

RECTANGULAR - OPPOSED BLADE / ROUND - BUTTERFLY

RECTANGULAR - OPPOSED BLADE / ROUND - BUTTERFLY

VARIABLE FREQUENCY DRIVEVFD

FOS

UF

ORL

FD / TD

RD / ORD

VCP / PVC

HR / HB

UNO UNLESS NOTED OTHERWISE ETR EXISTING TO REMAIN

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

Dwg. of o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

/2

/2

:2

:1

P

M B

IM

/1

R

A tr ia x M u rf re e s b o ro

C M

O P

/2

-0

-M E

C H

-R

.r v t

M-001

MECHANICAL COVER SHEET MEDS BY MAIL OFFICE

EXPANSION AT THE

MID-SOUTH CMOP

3209 ELAM FARMS PKWY, MURFREESBORO, TN 67127

764-21-101

N/A

03/25/2022 TJS KWP 10 17

PRESSURE CLASS SCHEDULE

AIR SYSTEM PRESSURE CLASS

SEAL

CLASS

LEAKAGE CLASS

ROUND RECT

GENERAL EXHAUST 2 INCH WG (500 PA) A 3 6

LOW-PRESSURE SUPPLY 2 INCH WG (500 PA) A 6 12

MEDIUM PRESSURE SUPPLY (UPSTREAM OF

VAV & CV BOXES)

6 INCH WG (1500 PA) A 3 6

RETURN AND RELIEF 2 INCH WG (500 PA) A 6 12

1.

REMARKS:

HVAC DESIGN CONDITIONS

SPACE OR AREA

OUTDOOR AIR INDOOR

HEATING

°F

INDOOR

COOLING

°F

RELATIVE

HUMIDITY

%RH

REMARKSSUMMER

DB/WB °F

WINTER

DB °F

MEDS BY MAIL EXPANSION 95/76 15 70 75 50 --

SHEET LIST

M-001 MECHANICAL COVER SHEET

M-101 HVAC & PLUMBING PLAN

M-201 MECHANICAL DETAILS & SCHEDULES

Revisions: Date:

T

T

T

T

T

OFFICE

OFFICE

OFFICE

COFFEE

SCANNER/MAIL

PROCESSING

RECORDS ROOM

SUPPLY ROOM

RETURN MEDS ROOM

(E) HSK

(E) SWITCH ROOM

CUBICLES

CORRIDOR

HALLWAY

HALLWAY

(E) COMPUTER TRAINING

(E) GROUP FITNESS

(E) STOR

(E) WORKOUT ROOM

(E) WOMEN

(E) MEN

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OCCUPATIONAL HEALTH

(E) STORAGE

(E) STAIR

E ( )56x30 E ( )82x36

E x2

E ( )6"ø

( ) E 1/2"

( ) E 1/2"

(E)1/2"HW &

1 1/4"CW DN

(E)WH-4

( ) E 1/2"

( ) E 1/2"

( ) E 1"

(E)4"VTR

AND 4"W DN

( ) E 1/2"

( ) E 1"

(E)-245 (E)-245

E ( )12"ø

(E)22x22

(E)VAV

) 1 0" ø

E ( )10"ø

P02P02

2"W

1/2"1/2"

P03 x2

36x24

SJ8

SL8

SL8

SJ8

SJ8

SJ8

SJ8

SJ8

SJ8

SJ8

SJ8

SJ8

SJ8

SJ8

SJ8

100 SJ8

SJ8

SJ8

PL22x10

PL22x10

PO22x10 PO22x10

PM22x22

PL22x10

PL22x10PL22x10 PL22x10

EXISTING AIR VOLUME SERVED = 7740 CFM.

VAV-13

(575)

VAV-14

(550)

VAV-15

(700)

VAV-16

(1000)

VAV-17A

(600)

EXISTING MEDIUM VELOCITY DUCT SIZED FOR

APPROXIMATE MAXIMUM 12,500 CFM TOTAL @ 0.3"/100'

MAXIMUM FRICTION LOSS, 2500 FPM MAXIMUM VELOCITY.

EXISTING UTILIZED AIR VOLUME = 7,740 CFM.

NEW UTILIZED AIR VOLUME = 10,565 CFM.

FD

H01

H02

SK-1

SY16x4

SY16x4

SY16x4

SY16x4

RW22x10

SL8

8x8

12x12

8x

8"ø

10"ø

10"ø

10"ø x1

12x12

8x

12x12 10x10

10"ø x1

26x20

H03

NEW SYSTEMS SHALL BE COMPATIBLE WITH EXISTING

HONEYWELL "NIAGARA WEB-600" CONTROLS AS INSTALLED BY

C-TECH CONTROLS (888-868-1688, ctechcontrols.com). NEW

THERMOSTATS SHALL MATCH EXISTING BUILDING STANDARD.

ALL LOW VOLTAGE HVAC CONTROLS CABLING SHALL BE

PROVIDED AND INSTALLED BY TCC. COORDINATE WITH TCC.

1-1/2''

2"CO

(E)FD

(E)FD

"ø

(OBD) (OBD)

H04

P01

EXISTING FIRE SPRINKLER SYSTEM SERVING THE OPEN

MEZZANINE SHALL BE MODIFIED TO SERVE ALL SPACES UNDER

THE SCOPE OF THIS PROJECT. EXISTING SPRINKLER SYSTEM

IS HIGH IN SPACE AND WILL NEED TO BE REROUTED DOWN TO

PROJECT CEILING LEVEL..

VAV-13

8x

H05

H06

"ø

SW12x8

SW12x8

"ø

H07

(10x10) (8x8)

H05

(1 0x

(8")

H08 H08

H07 H07

H07

VAV-17 AND ALL ASSOCIATED

DUCTWORK AND EQUIPMENT

SHOWN WITH A DARK GREY

FILL ARE TO BE PART OF

ALTERNATE #1.

H09H09

MECHANICAL GENERAL NOTES

1. DUCT SIZES SHOWN ARE ACTUAL INSIDE CLEAR

DIMENSIONS. INSULATION THICKNESS HAS NOT BEEN

ACCOUNTED FOR. DUCTWORK EXPOSED TO SPACE

SHALL NOT HAVE EXTERIOR INSULATION.

2. THE SPACE ABOVE THE CEILING IS BEING UTILIZED AS A

RETURN AIR PLENUM. ALL RETURN GRILLES SHALL BE

PROVIDED WITH SOUND BOOTS AND A DIRECT PATH TO

THE AIR HANDLING SYSTEM RETURN AIR DUCT SHALL BE

PROVIDED. WHERE FULL HEIGHT WALLS ARE BEING USED

AND THE RETURN AIR PATH IS COMPROMISED, THE

SOUND BOOT SHALL EXTEND THROUGH THE WALL OR

TRANSFER DUCTS SHALL BE PROVIDED.

3. AVOID ROUTING DUCTWORK OVER ELECTRICAL ROOMS

AND ELECTRICAL PANELS. MAINTAIN N.E.C.

CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL

CONTRACTOR.

4. ALL SUPPLY AIR BRANCHES FOR SUPPLY DIFFUSERS TO

HAVE MANUAL BALANCE DAMPERS, ALL MAY NOT BE

SHOWN FOR CLARITY.

5. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO

ALL MOTORIZED EQUIPMENT.

6. REFER TO GRD SCHEDULE FOR DUCT CONNECTION

SIZES. REFER TO TERMINAL BOX SCHEDULE FOR INLET

DUCT SIZES.

7. CEILING COORDINATION OF ALL MEP SYSTEMS

(LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL, ETC.)

MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO

THE START OF ANY NEW INSTALLATION.

8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE

SIZES TO INDIVIDUAL FIXTURES.

9. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY

SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON

WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE

AND FOR REASONABLE MAINTENANCE BASED ON ACTUAL

FIELD INSTALLATION.

10. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN

CEILINGS IN ACCESSIBLE LOCATIONS, OR WITH ACCESS

PANELS IN HARD LID CEILINGS.

11. PROVIDE ACCESSIBLE SHUT-OFF VALVES TO ALL

APPLIANCES AND EQUIPMENT.

12. CEILING PLENUM IS USED AS A RETURN AIR PATH. KEEP

PLENUM FREE OF COMBUSTIBLES, PVC PIPING AND ANY

OTHER MATERIALS NOT ALLOWED BY THE IFC.

13. VERIFY AND REFER TO ARCHITECTURAL DIMENSIONAL

FLOOR PLAN FOR EXACT LOCATIONS OF ALL FIXTURES

AND EQUIPMENT.

14. NEW THERMOSTATS SHALL MATCH EXISTING BUILDING

STANDARD THERMOSTAT. COORDINATE WITH BUILDING

OWNER AND TCC.

FIRE PROTECTION NOTES

1. PIPING TO BE BLACK IRON WITH SCREWED MALLEABLE

IRON FITTINGS OR MECHANICAL GROOVE FITTINGS. SEE

SPECIFICATIONS FOR DETAILS AND APPLICATIONS.

2. PIPE HANGERS TO BE U.L. LISTED AND MOUNTED IN

ACCORDANCE WITH NFPA-13.

3. DO NOT OBSTRUCT SPRINKLERS WITH OTHER UTILITIES.

4. SEE SPECIFICATIONS FOR SPRINKLER HEAD TYPES AND

APPLICATIONS. ALL SPRINKLER HEADS TO BE QUICK-

RESPONSE TYPE. ALL SPRINKLER HEADS SHALL BE

LOCATED IN EXACT CENTER OF CEILING TILES.

5. FIRE SPRINKLER DESIGN IS THE RESPONSIBILITY OF

THE FIRE SPRINKLER CONTRACTOR. FINAL DESIGN

SHALL BE SEALED BY A REGISTERED LICENSED

ENGINEER IN THIS STATE. FIRE MARSHALL APPROVED

SHOP DRAWINGS SHALL BE SUBMITTED TO THE DESIGN

ENGINEER FOR APPROVAL.

6. COORDINATE PIPE ROUTING AND HEAD LOCATIONS

WITH OTHER TRADES. PIPING AND HEADS NOT

COORDINATED SHALL BE MOVED AT THE

CONTRACTOR'S EXPENSE TO ACCOMPLISH CEILING

HEIGHTS AS CALLED OUT ON THE ARCHITECT'S

DRAWINGS.

7. COORDINATE CLOSELY WITH ALL OTHER TRADES PRIOR

TO CONSTRUCTION AND PROVIDE BIM MODEL TO

CONSTRUCTION MANAGER FOR COORDINATION AMONG

DISCIPLINES IF APPLICABLE.

8. FIRE PROTECTION ENGINEER OF RECORD SHALL

DETERMINE HAZARD CLASSIFICATIONS.

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

Dwg. of o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

KEYPLAN

AREA OF CONSTRUCTION

/2

/2

:2

:2

P

M B

IM

/1

R

A tr ia x M u rf re e s b o ro

C M

O P

/2

-0

-M E

C H

-R

.r v t

M-101

HVAC & PLUMBING PLAN MEDS BY MAIL OFFICE

EXPANSION AT THE

MID-SOUTH CMOP

3209 ELAM FARMS PKWY, MURFREESBORO, TN 67127

764-21-101

N/A

03/25/2022 TJS KWP 11 17

0' 8' 12'4' 1/4" = 1'-0"

HVAC & PLUMBING PLAN

A

PLAN NOTES

H01 36x24 RETURN AIR TRANSFER DUCT TURNED UP.

REFER TO RETURN AIR TRANSFER DUCT DETAIL.

H02 TEST AND BALANCE CONTRACTOR TO PROVIDE

PRE-CONSTRUCTION READING OF TOTAL AIRFLOW

FROM EXISTING ROOFTOP UNIT. UNIT SHALL BE

REBALANCED AT CONCLUSION OF PROJECT TO

PROVIDE AN ADDITIONAL 2,825 CFM BASED ON NEW

WORK. COORDINATE REQUIREMENTS WITH

TEMPERATURE CONTROLS CONTRACTOR.

H03 26x20 RETURN AIR TRANSFER DUCT TURNED UP.

H04 MOUNT BOTTOM OF GRILLE @ APPROXIMATELY 10'-6".

COORDINATE EXACT HEIGHT WITH ARCHITECT.

H05 VAV-17 AND ALL ASSOCIATED DUCTWORK, DIFFUSERS,

ETC SHOWN WITH A DARK GREY FILL ARE TO BE PART

OF ALTERNATE #1. REFER TO SPECIFICATIONS AND

ADDITIONAL NOTES ON VAV-16 FOR FURTHER

ALTERNATE INFORMATION.

H06 IF TAKING ALTERNATE #1, USE VAV-16A SCHEDULED

DATA. OTHERWISE USE VAV-16 SCHEDULED DATA.

REFER TO DUCT SIZE NOTES IF TAKING ALTERNATE

#1.

H07 SIZE INDICATED IN PARENTHESIS INDICATES DUCT

SIZE IF TAKING ALTERNATE #1.

H08 DUCTWORK TO BE OMITTED IF TAKING ALTERNATE #1.

H09 GRILLE MOUNTED WITH BOTTOM @ APPROXIMATELY

11'-0". COORDINATE EXACT HEIGHT WITH ARCHITECT.

ORIENT BLADES IN DOWNWARD DIRECTION.

P01 CONNECT 2" WASTE TO EXISTING WASTE LINE

SERVING EXISTING FD & MOP BASIN IN FIRST FLOOR

CEILING PLENUM.

P02 CONNECT 1/2" CW, 1/2" HW TO EXISTING 3/4" CW, 3/4"

HW ABOVE EXISTING WATER HEATER.

P03 CONNECT 1-1/2" VENT TO EXISTING VENT LINE NEAR

THIS LOCATION.

N

CEILING GRID

LAY - IN RETURN

AIR GRILLE

SHEET METAL DUCT

WITH 1/2" ACOUSTICAL

DUCT LINER

HANGER STRAP

OPENING TO RETURN

AIR PLENUM, SAME SIZE

AS GRILLE NECK.

NECK SIZE 18"

DIMENSION AS REQUIRED

TO CLEAR BUILDING

CONSTRUCTION (8" MIN)

COMPLETELY SEAL WALL

AROUND DUCT PENETRATION

FULL HEIGHT

PARTITION WALL

END OF DUCT OPEN TO CEILING

PLENUM (TYPICAL BOTH ENDS)

DOUBLE WALL PERFORATED

GALVANIZED SHEET METAL

TURNING VANES WITH ANGULAR

SPACE PACKED WITH FIBERGLASS

SHEET METAL DUCT

(REFER TO PLANS OR

TRANSFER CALLOUT FOR SIZE)

NOTES:

1. INSTALL RETURN AIR TRANSFER

DUCT ABOVE CEILING.

2. LOCATE SO THAT OPEN ENDS OF

DUCT ARE NOT OBSTRUCTED BY

OTHER DUCTS OR PIPING WITHIN

12" OF DUCT.

3. INSTALL FIRE DAMPERS OR FIRE/

SMOKE DAMPERS AS SHOWN

ON PLANS.

PLAN VIEW

24" MIN.

STRAIGHT GALV.

INSULATED DUCT MINIMUM

DISTANCE OF 3.0 TIMES

BOX INLET DUCT DIAMETER

AIRFLOW SENSOR

HEATING COIL

TRANSITION TO LOW

VELOCITY DUCTWORK

LOW VELOCITY SUPPLY AIR DUCT

SEE FLOOR PLANS FOR SIZE AND

ROUTING. TRANSITION AS REQUIRED

TO MATCH BOX OUTLET SIZE

MIN. 36" CLEAR

CONTROL BOX

SHEET METAL TRANSITION

AS REQUIRED (REFER TO

ACTUAL SUBMITTAL)

HIGH EFFICIENCY TAKEOFF

MEDIUM VELOCITY

TRUNK DUCT

FLOW FLOW

MINIMUM OF 12" STRAIGHT DUCT,

SAME AS VAV BOX OUTLET, OR AS

REQUIRED BY MFR PRIOR TO

TAKEOFFS, ELBOWS, OR FITTINGS.

HANGER ROD TO STRUCTURE

ANVIL FIG 260 OR EQUAL HEAVY

DUTY CLEVIS HANGER SIZED FOR

INSULATION THICKNESS

PIPE INSULATION W/ VAPOR

BARRIER. REFER TO

SPECIFICATIONS FOR

INSULATION THICKNESS.

FOAM GLASS HIGH DENSITY

INSERT W/ VAPOR BARRIER

ANVIL FIG 167 INSULATION SADDLE SHIELD

14 GA GALVANIZED x 24" LONG

NOTE:

OMIT FOAM GLASS INSERT ON

PIPES 3" AND LARGER

DIRECTION OF AIRFLOW. RECTANGULAR MAIN

OR TRUNK DUCT

MANUAL OPPOSED BLADE

BALANCING DAMPER WITH

LOCKING QUADRANT, ON BRANCH

DUCT OR WHERE INDICATED. NO

OBD ON MEDIUM PRESSURE DUCTS

BEFORE VAVs. TYPICAL.

STANDOFF FOR INSULATION

THICKNESS. TYPICAL.

SUPPLY

EXHAUST

RETURN

L=4" MINIMUM OR 1/4 OF "W"

W

45° L

ROUND MAIN OR

TRUNK DUCT

"LOW-LOSS" 45°F

ENTRY FITTING

GASKET

HIGH EFFICIENCY

TAKEOFF (HETO).

SUPPLY

EXHAUST

RETURN

45°

HIGH EFFICIENCY

TAKEOFF (HETO)

ROUND BRANCH DUCT

GASKET

MANUAL BUTTERFLY BALANCE

DAMPER WITH LOCKING QUADRANT

STANDOFF FOR

INSULATION THICKNESS

LOW VELOCITY

SUPPLY DUCT

SHORT RADIUS RIGID METAL ELBOW

WHERE 1.5D FLEX ELBOW CAN NOT BE

MAINTAINED

DUCT WRAP INSULATION

PER SPECIFICATIONS

REFER TO SURFACE-MOUNTED

DIFFUSER DETAIL FOR INSTALLATION

REQUIREMENTS

LAY-IN CEILING

TILE, TYPICALTEE-BAR

GRID, TYPICAL

NYLON STRAP

FASTENER, TYPICAL

STRAP HANGER

INSULATED FLEX DUCT, 6'-0"

MAXIMUM LENGTH, ALLOWED

ABOVE LAY-IN CEILINGS AT SUPPLY

DIFFUSERS ONLY, TYPICAL

SUPPLY DIFFUSER

AS SCHEDULED,

TYPICAL

1.5DM

AX

DIRECTION OF AIRFLOW

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

Dwg. of o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

/2

/2

:2

:2

P

M B

IM

/1

R

A tr ia x M u rf re e s b o ro

C M

O P

/2

-0

-M E

C H

-R

.r v t

M-201

MECHANICAL DETAILS & SCHEDULES MEDS BY MAIL OFFICE

EXPANSION AT THE

MID-SOUTH CMOP

3209 ELAM FARMS PKWY, MURFREESBORO, TN 67127

764-21-101

N/A

03/25/2022 TJS KWP 12 17

1.

2.

3.

4.

ALL TERMINAL UNITS SHALL BE PROVIDED WITH FLOW-RING SERVICE 'T'.

ALL ELECTRIC TERMINAL UNITS SHALL BE PROVIDED WITH INDEPENDENT DISCONNECT SWITCH AND FUSE BLOCK BY EQUIPMENT MANUFACTURER.

PROVIDE THERMOSTAT COMPATIBLE WITH EXISTING DDC SYSTEM. NEW SYSTEMS SHALL BE COMPATIBLE WITH EXISTING HONEYWELL "NIAGARA WEB-600" CONTROLS AS INSTALLED BY C-TECH CONTROLS (888-868-1688, ctechcontrols.com). ALL LOW VOLTAGE HVAC CONTROLS CABLING SHALL BE PROVIDED AND INSTALLED BY TCC. COORDINATE WITH TCC.

TERMINAL UNIT TO BE PROVIDED BY ALTERNATE #1. VAV-16 TO BE OMITTED IF TAKING ALTERNATE #1.

REMARKS:

TERMINAL UNIT SCHEDULE

MARK

BASED ON

UNIT

SIZE

INLET

SIZE

(INCH)

PRIMARY AIRFLOW

OP SP

(IN WC)

MAX

NC

RAD

HEATING COIL

EMERGENCY

POWER

LINER

TYPE

REMARKS

MFR MODEL

MAX

(CFM)

MIN

(CFM)

AIR ELECTRIC COIL

CFM

EAT

(°F)

LAT

(°F)

CAP

(KW)

VOLT PHASE STEPS MCA MOP

VAV-13 TITUS DESV 8 8" 575 175 1 30 320 55 89.6 3.5 277 1 SCR 15.8 20 No FIBER FREE 1-3

VAV-14 TITUS DESV 8 8" 550 175 1 30 275 55 89.5 3 277 1 SCR 13.5 15 No FIBER FREE 1-3

VAV-15 TITUS DESV 8 8" 700 225 1 30 350 55 86.6 3.5 277 1 SCR 15.8 20 No FIBER FREE 1-3

VAV-16 TITUS DESV 10 10" 1000 300 1 30 550 55 86.6 6.5 277 1 SCR 29.3 30 No FIBER FREE 1-3

VAV-16A TITUS DESV 6 6" 400 125 1 30 200 55 92.3 2 277 1 SCR 9.0 15 No FIBER FREE 1-4

VAV-17A TITUS DESV 8 8" 600 200 1 30 300 55 86.6 3 277 1 SCR 13.5 15 No FIBER FREE 1-4

S R P E L M C U

SUPPLY DIFFUSER

RETURN GRILLE

PLENUM RETURN GRILLE

EXHAUST GRILLE

SLOT DIFFUSER

LAMINAR FLOW SUPPLY DIFFUSER

SECURITY GRILLE

FLOOR MOUNTED SUPPLY GRILLE

1.

2.

3.

4.

5.

6.

7.

8.

PROVIDE SQUARE TO ROUND ADAPTERS AS REQUIRED TO ACCOMODATE ROUND RUNOUTS.

PROVIDE ALL LAY-IN GRDs WITH 24x24 LAY-IN PANEL AS REQUIRED.

FINISH TO BE WHITE UNLESS OTHERWISE SPECIFIED. COORDINATE AND VERIFY ALL FINISHES WITH ARCHITECT.

ALL SELECTIONS ARE BASED ON A MAXIMUM NC OF 25 UNLESS NOTED OTHERWISE.

CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND ASSOCIATED BORDER TYPES.

MARKS USED MAY NOT BE IN SEQUENCE.

LOUVERED GRILLES TO HAVE FRONT BLADES PARALLEL TO LONG DIMENSION UNLESS WALL MOUNTED.

WALL MOUNTED LOUVERED GRILLES TO HAVE FRONT BLADES PARALLEL TO FLOOR.

FIRST LETTER IN MARK: NOTES:

GRILLE, REGISTER, AND DIFFUSER SCHEDULE

MARK TYPE IMAGE

BASED ON

MOUNT PANEL SIZE

(FACE SIZE)

MATERIAL

BLADE SPACING /

SLOT WIDTH

DEFLECTION COLOR REMARKS

MFR MODEL

SJ SUPPLY DIFFUSER TITUS OMNI-AA LAY-IN 24x24 ALUMINUM -- -- WHITE --

SL SUPPLY DIFFUSER TITUS OMNI-AA SURFACE 24x24 ALUMINUM -- -- WHITE --

SW WALL SUPPLY TITUS 300FS WALL SEE PLANS ALUMINUM 3/4" DOUBLE

MATCH

WALL

SY

DUCT MOUNTED

SUPPLY

TITUS S300FS DUCT SEE PLANS ALUMINUM 3/4" DOUBLE

MATCH

DUCT

AIR SCOOP DAMPER

PL

RETURN GRILLE

(PLENUM RETURN)

TITUS 45F LAY-IN

24x12 (22x10)

ALUMINUM -- 45° WHITE REFER TO SOUND TRAP DETAIL

PM

RETURN GRILLE

(PLENUM RETURN)

TITUS 45F LAY-IN

24x24 (22x22)

ALUMINUM -- 45° WHITE REFER TO SOUND TRAP DETAIL

PO

RETURN GRILLE

(PLENUM RETURN)

TITUS 45F SURFACE

24x12 (22x10)

ALUMINUM -- 45° WHITE REFER TO SOUND TRAP DETAIL

RW WALL RETURN TITUS 350FL/S WALL SEE PLANS ALUMINUM 3/4" 35°

MATCH

WALL

PLUMBING FIXTURE SCHEDULE

MARK DESCRIPTION MANUFACTURER MODEL DIMENSIONS

ADA

COMPLIANT

MATERIAL DESCRIPTION &

FINISH

TRIM

FLOW

FIXTURE

FLUSH

FIXTURE

PIPE RUNOUT SIZES

SPECIFICATION

MANUFACTURER MODEL

CONTROL

TYPE

POWER FLOW (GPM)

VOLUME

PER FLUSH

(GAL)

COLD

WATER

HOT

WATER

WASTE VENT

SK-1 SINK - SINGLE BOWL ELKAY LRAD191865

19" x 18" x 6-1/2" (16" x

11-1/2" BOWL)

Yes STAINLESS STEEL ELKAY "AVADO" LKAV3031LS MANUAL -- 1.8 -- 1/2" 1/2" 2" 1-1/2"

SINGLE HOLE DRILLING - FAUCET WITH PULL DOWN SPRAY, LEVER HANDLE, CERAMIC DISC VALVE, LESS ESCUTCHEON - LEONARD 170-OF ASSE 1070 THERMOSTATIC MIXING VALVE IN HOT WATER SUPPLY SET TO 105°F - GRID DRAIN - WALL SUPPLIES WITH QUARTER TURN STOPS - LKAD35 OR EQUAL OFFSET DRAIN WITH GRID STRAINER - 1-1/2" CHROME PLATED CAST BRASS P-TRAP. INSULATE AS REQUIRED FOR ADA COMPLIANCE.

NO SCALE

RETURN GRILLE SOUND TRAP DETAIL

NO SCALE

RETURN AIR TRANSFER DUCT

NO SCALE

TERMINAL UNIT REHEAT DETAIL

NO SCALE

PIPE HANGER DETAIL

NO SCALE

DUCT TAKEOFF DETAILS

NO SCALE

DIFFUSER INSTALLATION DETAIL - SLOT

ONE-LINE

LSIG = LONG TIME, SHORT TIME,

INSTANTANEOUS, GROUND FAULT

GFI = GROUND FAULT

DISCONNECT SWITCH (SEE EQUIP

CONN SCHED)

CIRCUIT BREAKER

OVERLOADS

FUSE

INDICATOR LIGHT(G=GREEN, R=RED)

CIRCUIT BREAKER ACCESSORIES:

CONTACTS (N.O., N.C.)

K = KIRK KEY INTERLOCK

(CIRCUIT NUMBER / SWITCH SIZE

/ FUSE SIZE / # OF POLES) (# OF

POLES IF OTHER THAN 3)

FUSIBLE SWITCH

ST = SHUNT TRIP

DRAWOUT CONTACTS

G

A

A

A A

AT

AFA

PANEL

M M

VFD AT

RV

SPD

LSIG

GFI

ST

K

'1'

HP KW

N

ATS

E

'1'

(VOLTAGE / SWITCH SIZE / FUSE

SIZE / # OF POLES - NOTED IF

EQUIPMENT NOT SCHEDULED)

STARTER (SEE EQUIP CONN SCHED)

(VOLTAGE / STARTER SIZE /

# OF POLES - NOTED IF

EQUIPMENT NOT SCHEDULED)

GROUND CONNECTION

LIGHTNING ARRESTOR

FEEDER DESIGNATION

SURGE PROTECTIVE DEVICE

(CIRCUIT NUMBER / SWITCH

SIZE / FUSE SIZE / # OF POLES

/ STARTER SIZE) (# OF POLES

IF OTHER THAN 3)

STARTER WITH FUSIBLE SWITCH

2P

2P

(CIRCUIT NUMBER / TRIP SIZE / #

OF POLES) (FRAME SIZE / TRIP

SIZE) (# OF POLES IF OTHER

THAN 3)

CIRCUIT BREAKER (MOLDED CASE

NON-ADJUSTABLE TRIP /

ADJUSTABLE TRIP)

2P 2P

3Ø TRANSFORMER (DELTA PRIMARY

/ WYE SECONDARY)

1Ø TRANSFORMER

METER (UTILITY / PANEL MOUNTED)

EQUIPMENT (SINGLE MOTOR / MULTI-

MOTOR OR OTHER TYPE AS NOTED)

VARIABLE FREQUENCY DRIVE

(HP SIZE IF NOT SCHEDULED)

PANELBOARD

(BUILT-IN SPD)

SPD

TRANSFER SWITCH (ATS =

AUTOMATIC, MTS = MANUAL)

MOTOR STARTER [SINGLE SPEED

ACROSS-THE-LINE (UON)]

(AMP SIZE / VOLTAGE / POLES

/ AIC RATING / NEMA RATING)

(NEMA RATING IF OTHER

THAN NEMA-1)

(NEMA SIZE /

RV AT= REDUCED VOLTAGE /

AUTO-TRANSFORMER /

SS = SOLID STATE)

T1. EACH DATA, TELEPHONE, VIDEO, OR OTHER SYSTEMS

OUTLET REQUIRES 1"C. WITH PULL ROPE STUBBED 6"

ABOVE NEAREST ACCESSIBLE CEILING UNLESS

OTHERWISE NOTED ON PLANS. CONDUITS STUBBED

UP ABOVE CEILINGS SHALL BE TURNED OUT 90

DEGREES. PROVIDE INSULATED BUSHINGS ON ALL

CONDUITS. LABEL CONDUIT TO IDENTIFY ITS

INTENDED USE (I.E. TELEPHONE, DATA, ETC.).

COMMUNICATION / DATA

F1. THE FIRE ALARM SYSTEM SHOWN HAS BEEN DESIGNED

PER THE REQUIREMENTS OF NFPA 72, 2013 EDITION.

DEVICES SHOWN INDICATE DESIGN INTENT AND SHALL

BE THE MINIMUM PROVIDED. SYSTEM SUPPLIER SHALL

PROVIDE ANY ADDITIONAL CODE REQUIRED DEVICES OR

DEVICES REQUIRED BY THE AUTHORITY HAVING

JURISDICTION.

F2. FIELD VERIFY LOCATIONS OF AREA SMOKE DETECTORS

AND HEAT DETECTORS. DO NOT LOCATE WITHIN 36" OF

A HVAC DIFFUSER (SUPPLY OR RETURN), IN A DIRECT

AIR FLOW, WITHIN 36" OF A SPRINKLER HEAD, OR WITHIN

36" OF THE TIP OF A CEILING FAN BLADE. SMOKE

DETECTORS FOR DOOR RELEASE SHALL BE LOCATED

ON THE CENTER LINE OF THE DOOR AND A MAXIMUM OF

5 FEET FROM THE DOOR. THE MINIMUM DISTANCE FROM

THE DOOR IS THE DEPTH OF THE WALL SECTION ABOVE

THE DOOR, BUT NOT LESS THAN 12".

F4. LABEL REMOTE ALARM INDICATOR FOR DUCT

MOUNTED SMOKE DETECTORS (I.E. RTU-=1 SUPPLY,

RTU-2 RETURN, FIRE/SMOKE DAMPER, ETC.). DUCT

DETECTORS SHOULD BE LOCATED IN THE AREA

BETWEEN 6 AND 10 DUCT EQUIVALENT DIAMETERS

OF STRAIGHT, UNITERRUPTED DUCTWORK. DUCT

DETECTORS FOR FIRE/SMOKE DAMPERS SHOULD

BE LOCATED BETWEEN THE LAST INLET OR OUTLET

UPSTREAM OF THE DAMPER AND THE FIRST INLET

OR OUTLET DOWNSTREAM OF THE DAMPER.

F3. FAN SHUTDOWN RELAY WIRING SHALL BE LOCATED

WITHIN 3 FEET OF THE FAN CONTROLS AND THE WIRING

TO THE RELAY SHALL BE MONITORED.

F5. PROVIDE 120V POWER AND FUSTAT FOR EACH

FIRE/SMOKE DAMPER. INTERLOCK WITH FIRE ALARM

CONTROL PANEL TO CLOSE THE FIRE/SMOKE DAMPER

UPON ANY ALARM AT THE FIRE ALARM CONTROL PANEL

AND TO SHUTDOWN THE ASSOCIATED MECHANICAL UNIT.

FIRE ALARM

1. ALL ELECTRICAL WORK SHALL COMPLY WITH THE

LATEST EDITION OF THE NATIONAL ELECTRICAL CODE

(NEC) & THE AMERICANS WITH DISABILITIES ACT (ADA).

2. REFER TO RELATED ARCHITECTURAL, MECHANICAL,

STRUCTURAL, AND CIVIL DRAWINGS FOR RELATED

INFORMATION.

3. REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE

DRAWINGS.

4. E.C. SHALL REFER TO MECHANICAL DRAWINGS AND

SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED

WITH WIRING AND CONNECTION OF INTERLOCKING AND

CONTROLS OF MECHANICAL UNITS AND THERMOSTAT

LOCATIONS.

5. COORDINATE OUTLET BOX LOCATIONS WITH MASONRY TO

MINIMIZE CUTTING OF BRICK OR BLOCK.

6. ALL MOUNTING HEIGHTS TO CENTERLINE OF ITEM UNLESS

OTHERWISE NOTED. VERIFY ALL OUTLET LOCATIONS ON

THE JOB PRIOR TO ROUGH-IN.

7. CONDUIT RUN W/CONDUCTORS AS INDICATED & GROUND

WIRE SIZED PER N.E.C. 250.122. CONDUIT SIZE AS

REQUIRED.

8. WHEN INCREASED CONDUCTOR SIZES ARE SHOWN ON

THE PLANS, THE LARGER CONDUCTOR SIZE SHALL BE

USED THROUGHOUT THE LENGTH OF THE CIRCUIT,

INCLUDING NEUTRAL AND GROUND.

9. "CT" INDICATED ADJACENT TO DEVICE INDICATES DEVICE

MOUNTED ABOVE BACKSPLASH OF COUNTER TOP.

VERIFY EXACT HEIGHT WITH ARCHITECTURAL PLANS AND

ELEVATIONS.

10. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME

RUNS WITH INDIVIDUAL NEUTRALS. A MAXIMUM OF THREE

CIRCUITS (MAXIMUM OF THREE PHASE CONDUCTORS) MAY

BE GROUPED IN A SINGLE CONDUIT. WHERE MULTIPLE

CIRCUITS ARE LOCATED IN THE SAME RACEWAY,

JUNCTION BOX OR ENCLOSURE, NEUTRALS SHALL BE

MARKED OR LABELED TO INDICATE WHICH CIRCUIT THEY

ARE ASSOCIATED WITH. SEE SPECIFICATION SECTION

"LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND

CABLES" FOR ADDITIONAL INFORMATION.

12. LABEL THE FRONT OF EACH RECEPTACLE COVERPLATE

WITH PANEL DESIGNATION AND CIRCUIT NUMBER

USING CLEAR THERMAL TRANSFER (ELECTRONIC

DYMO) LABELS WITH 1/8" HIGH BLACK LETTERS (OR

CONTRASTING COLOR IF COVERPLATES ARE BLACK OR

BROWN). LABELS SHALL BE SUITABLE FOR

INDOOR/OUTDOOR USE. LABEL THE BACK OF EACH

LIGHT SWITCH COVERPLATE WITH PANEL DESIGNATION

AND CIRCUIT NUMBER USING A FINE BLACK

PERMANENT MARKER.

11. JUNCTION BOX OR RECEPTACLE FOR DRINKING FOUNTAINS

SHALL BE LOCATED BEHIND THE EQUIPMENT SKIRT UNLESS

OTHERWISE NOTED. COORDINATE CONNECTION TYPE AND

LOCATION WITH EQUIPMENT PROVIDED.

13. PROVIDE 18" LONG (MIN.) CONDUIT SLEEVES THRU ALL

WALLS WHERE CABLES ARE INDICATED OR REQUIRED TO

PASS THRU WALLS. PROVIDE BUSHINGS ON BOTH ENDS.

SIZE CONDUIT FOR CABLES INSTALLED. AT CABLE TRAYS,

PROVIDE ONE 4" CONDUIT SLEEVE FOR EACH 4" WIDTH OF

CABLE TRAY. MAXIMUMS SHALL BE:

1"C. = 10 CABLES

2 1/2"C. = 20 CABLES

3"C. = 30 CABLES

4"C. = 50 CABLES

14. LOCATE CABLE TRAYS 6" ABOVE CEILING. OFFSET TRAY

UP AND OVER LIGHT FIXTURES AND DUCTWORK (FIELD

VERIFY AND PROVIDE AS REQUIRED). IF PHYSICALLY

IMPOSSIBLE TO RUN CABLE TRAY UP AND OVER, THEN

PROVIDE CABLE SUPPORT HOOKS FROM STRUCTURE

ABOVE, SIZED AND RATED FOR INSTALLED CABLES PLUS

25% SPARE.

15. PROVIDE DIMMER PER THE SPECIFICATIONS.

COORDINATE DIMMER TYPE AND WIRING WITH

ASSOCIATED LIGHT FIXTURE DIMMING REQUIREMENTS (I.E.

3-WIRE, O-10V, ELECTRONIC OR MAGNETIC LOW VOLTAGE,

ETC.) OR WITH LIGHTING CONTROL SYSTEM PROPRIETARY

REQUIREMENTS (I.E. LUTRON, nLIGHT, DALI, ETC.) AS

NECESSARY. 3-WIRE DIMMERS SHALL BE PROVIDED WITH

A DEDICATED NEUTRAL FOR EACH CONTROL ZONE. 0-10V

DIMMERS SHALL BE PROVIDED WITH DIM/ON/OFF

CONTROL. COORDINATE PHASE CONTROL OF LED

DRIVERS (I.E. REVERSE PHASE, FORWARD PHASE, ETC.)

WITH LIGHT FIXTURE MANUFACTURER'S

RECOMMENDATIONS. LOW VOLTAGE CONTROL WIRING IS

NOT SHOWN ON PLANS FOR CLARITY, BUT SHALL BE

PROVIDED AS REQUIRED.

- - - SYMBOL LIST IS FOR REFERENCE ONLY. ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. - - -

- - - SYMBOL LIST IS FOR REFERENCE ONLY. ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. - - -

PEN WEIGHT LEGEND

LIGHT FIXTURE TO BE REMOVED

EXISTING LIGHT FIXTURE TO REMAIN

NEW LIGHT FIXTURE

DUPLEX GROUNDED REC TO BE REMOVED

EXISTING DUPLEX GROUNDED REC TO REMAIN

ALL DEVICES, LIGHT FIXTURES, ETC., DRAWN IN DARK

SOLID LINES ARE NEW TO BE INSTALLED

NEW DUPLEX GROUNDED RECEPTACLE

ALL DEVICES, LIGHT FIXTURES, ETC., DRAWN IN HALFTONE

SOLID LINES ARE EXISTING TO REMAIN

ALL DEVICES, LIGHT FIXTURES, ETC., DRAWN IN DARK

DASHED LINES ARE EXISTING TO BE REMOVED

LIGHT FIXTURE TO BE RELOCATED

DUPLEX GROUNDED REC TO BE RELOCATED

ALL DEVICES, LIGHT FIXTURES, ETC., DRAWN IN LIGHT

DASHED LINES ARE EXISTING TO BE RELOCATED

SECURITY

WALL M

E

W

W

K KEY PAD

SECURITY BEAM DETECTOR

GLASS BREAK SENSOR

CARD READER

MAGNETIC LOCK

ELECTRIC DOOR STRIKE

DOOR POSITION SWITCH

DOOR LOCK & POSITION SWITCHDOOR RELEASE BUTTON

CCTV CAMERA - FIXED

CCTV CAMERA - FIXED

CCTV CAMERA - PAN/TILT/ZOOM

DURESS

CCTV CAMERA - PAN/TILT/ZOOM

SEC ROOM MOTION DETECTOR

SEC ROOM MOTION DETECTOR

WALL

CEILING

CEILING

REQUEST TO EXIT DEVICE (MOTION)ED

WALL/CLG

SEC CORRIDOR MOTION DETECTOR

CEILING

B

CR

RE REQUEST TO EXIT DEVICE (PSHBTN) WALL

CONDUIT AND WIRING

PHASE CONDUCTORS/

NEUTRAL CONDUCTOR (#12 UON)

EMERGENCY CIRCUIT

CONDUIT RUN PARTIAL CIRCUIT.

2#12 & 1#12 GRD. - 1/2"C.

CDT RUN 2#12 & 1#12 GRD.- 1/2"C.

OR CDT RUN AS NOTED ON PLAN

CDT RUN 2#12 & 1#12 GRD.- 3/4"C.

OR CDT RUN AS NOTED ON PLAN

CLG/WALL

MASTER/SLAVE FIXTURE WHIP

CONDUIT HOME RUN, 2 CIRCUITS.

4#12 & 1#12 GRD. - 1/2"C.

CONDUIT HOME RUN, 1 CIRCUIT.

2#12 & 1#12 GRD. - 1/2"C.

CONDUIT HOME RUN, 3 CIRCUITS.

6#12 & 1#12 GRD. - 1/2"C.

CONDUIT HOME RUN, 1 CIRCUIT.

2#10 & 1#10 GRD. (GEN. NOTES 7 & 8)

#10

GROUND CONDUCTOR (#12 UON)

CONDUIT HOME RUN, 2 CIRCUITS

SWITCH LEGS (#12 UON)

CEILING

CLG/WALL

CLG/WALL

EARTH/

FLOOR

CLG/WALL

CLG/WALL

CLG/WALL

CLG/WALL

CLG/WALL

LOW VOLTAGE WIRING CLG/WALL

MISC. EQUIPMENT CONNECTION

CONDUIT SEAL OFF

FIRE ALARM

46"AFFFIRE ALARM MANUAL STATION

DUCT SMOKE DETECTOR &

FIRE/ SMOKE DAMPER (GEN

NOTES F4 & F5)

FIRE ALARM VISUAL SIGNAL

FIRE ALARM HORN

DUCT SMOKE DETECTOR

(GEN NOTE F4)

IONIZATION AREA SMOKE

DETECTOR (GEN NOTE F2)

PHOTO ELECTRIC AREA SMOKE

DETECTOR (GEN NOTE F2)

F.A. RELAY (GEN NOTE F3)R

CH CHIME

DUCTWORK

CEILING

FIRE ALARM CONTROL PANEL'FACP'

FIRE SPRINKLER ALARM BELL

WALL

BOTTOM 80"

COMB. F.A. HORN & VISUAL SIGNAL

BOTTOM 80"

BOTTOM 80"

FIRE ALARM SPEAKER

COMB FA SPEAKER & VISUAL SIGNAL

FIRE ALARM REMOTE ANNUNCIATOR'FAAP' WALL

COMB FA HORN & VISUAL SIGNAL

FSD DUCTWORK

WALL

WALL

WALL

BOTTOM 80"

FIRE SPRINKLER TAMPER SWITCH

ELECTROMAGNETIC DOOR HOLDER

FIRE SPRINKLER WATER FLOW SW

HEAT DETECTOR (GEN NOTE F2)

SPRKLR RSR

C FIRE ALARM CONTROL MODULE

FIRE ALARM MONITOR MODULE

FIRE ALARM SPEAKER

FIRE SPRINKLER PRESSURE SWITCH

FIRE ALARM SPEAKER

CEILING

WALL

WALL

SPRKLR RSR

CEILINGFIRE ALARM VISUAL SIGNAL

M

P

H

T

W

DH

1-VOICE OUTLET & JACK (GEN

NOTE T1)

1-VOICE/1-DATA OUTLET &

JACKS (GEN NOTE T1)

1-DATA OUTLET & JACK (GEN

NOTE T1)

18"AFF

CABLE TV OR VIDEO OUTLET &

CONNECTOR (GEN NOTE T1)

1-VOICE/2-DATA OUTLETS &

JACKS (GEN NOTE T1)

2-VOICE/2-DATA OUTLETS & JACKS

(GEN NOTE T1)

1-VOICE/3-DATA OUTLETS &

JACKS (GEN NOTE T1)

4-DATA OUTLETS & JACKS (GEN

NOTE T1)

2-DATA OUTLETS & JACKS (GEN

NOTE T1)

3-DATA OUTLETS & JACKS (GEN

NOTE T1)

18"AFF

18"AFF

18"AFF

18"AFF

18"AFF

18"AFF 18"AFF

18"AFF

18"AFF

COMMUNICATION / DATA

POWER

DUPLEX GROUNDED RECEPTACLE

FUSTAT BUSS #SSY

SPECIAL DEVICE (AS NOTED)

JUNCTION BOX - 1-GANG

DOUBLE DUPLEX GROUNDED REC

GROUND FAULT DUPLEX REC

DUPLEX GROUNDED RECEPTACLE

SINGLE GROUNDED RECEPTACLE

DUPLEX GRD REC BOTTOM SWITCHD

GRD FAULT DOUBLE DUPLEX REC

18" AFF

A

ELECTRICAL DISTRIBUTION EQUIP

EQUIPMENT - SEE EQUIPMENT

CONNECTION SCHEDULE

x-x x-x

CONDUIT SLEEVE (GEN NOTE 13)

CABLE TRAY (GEN NOTE 14)

FEEDER DESIGNATION

M MANUAL STARTER

CIRCUIT BREAKER

DISCONNECT SWITCH

M MOTOR

PLUGMOLD SURFACE RACEWAY

S

18" AFF

18" AFF

CEILING

18" AFF

18" AFF

18" AFF

FLOOR/WALL

72" TO TOP

WALL

JUNCTION BOX - 2-GANG

PLUG LOAD SENSOR CEILING

HANDICAP DOOR PUSHBUTTON 36" AFF

RELAY

PUSHBUTTON (1-BUTTON, 2-BUTTON)

BOX MOUNTED TRANSFORMER

46" AFF

CONTACTOR

METER

STARTER OR ATS (AS NOTED)

COMBINATION STARTER/DISC

BUSDUCT PLUG

THERMOSTAT/TEMP SENSOR 46" AFF

SPECIAL OUTLET (SEE

SCHEDULE OR AS NOTED)

BRANCH CIRCUIT PANEL AND

PANEL DESIGNATION

AA

TS

H

P

R

TAMPER-PROOF DUPLEX REC 18" AFF

TAMPER-PROOF GFCI DUPLEX REC 18" AFF

T

C

1J

J

F

1D

2M

SWITCHES (KEYED, PILOT, TIMER)

INDICATES SWITCHING SCHEME

EMERGENCY BATTERY LIGHT FIXT

LIGHT FIXTURE & FIXTURE LETTER

46" AFF

A

A

LIGHT FIXTURE & FIXTURE LETTER

LIGHT FIXTURE & FIXTURE LETTER

LIGHT FIXTURE & FIXTURE LETTER

STRIP LIGHT FIXTURE & FIXT LETTERA

A

A

A

1 RELAY OCCUPANCY SENSOR SW

2 RELAY OCCUPANCY SENSOR SW

OCCUPANCY SENSOR

1 RELAY OCCUPANCY SENSOR/

DIMMER SWITCH (GEN NOTE 15)

M

D DIMMER SWITCH (GEN NOTE 15)

ON/OFF SWITCH

S

DS DAYLIGHT SENSOR

CLG/WALL

46" AFF

46" AFFSSS

SSS

S a, b, c

CLG SURF/

RECESSED

CEILING

WALL

CEIL/WALL

WALL

CEIL/WALL

46" AFF

46" AFF

46" AFF

46" AFF

2 3 4

K P T

LIGHTING, SWITCHES AND SENSORS

SWITCHES (1-POLE, 2-POLE,

3-WAY, 4-WAY)

EXIT SIGN (SHADING DENOTES

EXIT FACE SIDE)

FIXTURE WITH SHADED LAMP(S)

ON EMERGENCY POWER

WALLCOMB EXIT SIGN/EM BATTERY LIGHT

LP LIGHTING CONTROL POWER PACK

EP UL-924 LISTED POWER PACK

46" AFF

ON/OFF/0-10V DIMMING SWITCH

S

46" AFF

DUAL TECH ON/OFF SENSOR

S

46" AFF

16-SCENE WALL CONTROLLER

S

46" AFF

DUAL TECH ON/OFF/0-10V DIM SW

S

46" AFF

LOW VOLTAGE SWITCH

S

A

A

A

A A

LIGHT FIXTURE & FIXTURE LETTERA POLEA

AV AV SYSTEM/LIGHTING INTERFACE

A

A CLG SURF/

RECESSED

A

CLG SURF/

RECESSED

A A

A

A

LIGHTING TRACK, TRACK FIXTURES,

& FIXTURE LETTERS CEILING

A AA

A A T

CEILING

PC PHOTOCELL

NIGHT LIGHT - WIRE AHEAD OF

ABBREVIATIONS

NL

EM

WP

CT

UON

ON EMERGENCY POWER

WEATHERPROOF

COUNTERTOP (SEE GEN. NOTE 9)

UNLESS OTHERWISE NOTED

ABOVE FINISHED FLOORAFF

AFG ABOVE FINISHED GRADE

WALLW

CONTROLS

DRINKING FOUNTAIN -

SEE GENERAL NOTE 11

DF

GAP GENERATOR ANNUNCIATOR PANEL

GENERAL NOTES

SYMBOL

SYMBOL LIST

DESCRIPTION MOUNTINGDESCRIPTIONSYMBOLMOUNTING SYMBOL

SYMBOL LIST

DESCRIPTION MOUNTINGDESCRIPTIONSYMBOLMOUNTING

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

Dwg. of o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

/2

/2

:0

:0

P

M B

IM

/1

R

A tr ia x

M u rf re e s b o ro C

M O

P /2

-0

E

L E

C R

.r v t

E-001

ELECTRICAL GENERAL NOTES AND

SYMBOLS

MEDS BY MAIL OFFICE

EXPANSION AT THE

MID-SOUTH CMOP

3209 ELAM FARMS PKWY, MURFREESBORO, TN 67127

764-21-101

N/A

03/25/2022 DDC KTN 13 17

ELECTRICAL SHEET INDEX

SHEET NO. SHEET TITLE

E-001 ELECTRICAL GENERAL NOTES AND SYMBOLS

E-101 POWER & SYSTEMS PLAN

E-102 LIGHTING PLAN

E-501 ELECTRICAL DETAILS

E-601 ELECTRICAL SCHEDULES

SPECIAL OUTLETS

MARK DESCRIPTION

SF1 SYSTEM FURNITURE WALL OUTLET: CONNECT SYSTEM FURNITURE PER DETAIL 7/E501.

VERIFY EXACT LOCATION WITH FURNITURE PROVIDER PRIOR TO ROUGH-IN.

CT

CT

J

J

J J

J J

J

J

E

E

E

E

E

E

POWER PLAN NOTES:

1. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS WITH

INDIVIDUAL NEUTRALS. A MAXIMUM OF THREE CIRCUITS (MAXIMUM OF

THREE PHASE CONDUCTORS) MAY BE GROUPED IN A SINGLE CONDUIT.

WHERE MULTIPLE CIRCUITS ARE LOCATED IN THE SAME RACEWAY,

JUNCTION BOX OR ENCLOSURE, NEUTRALS SHALL BE MARKED OR LABELED

TO INDICATE WHICH CIRCUIT THEY ARE ASSOCIATED WITH. SEE

SPECIFICATION SECTION "LOW VOLTAGE ELECTRICAL POWER

CONDUCTORS AND CABLES" FOR ADDITIONAL INFORMATION.

2. A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL

CONDUITS.

3. FOR CONNECTION REQUIREMENTS TO MECHANICAL UNITS, SEE

MECHANICAL EQUIPMENT CONNECTION SCHEDULE.

4. REFER TO THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR

LOCATIONS OF FIRE RATED WALLS AND CEILINGS AND THE ASSOCIATED

U.L. ASSEMBLY NUMBERS.

5. FOR ALL PENETRATIONS IN FIRE RATED WALLS AND CEILINGS, PROVIDE AN

ASTM E814 COMPLIANT, U.L. LISTED THROUGH PENETRATION FIRE

STOPPING SYSTEM THAT IS SPECIFIC TO THE WALL OR CEILING

CONSTRUCTION ASSEMBLY. INSTALL SYSTEM IN STRICT COMPLIANCE

WITH THE U.L. ASSEMBLY INDICATED IN THE ARCHITECTURAL DRAWINGS

AND SPECIFICATIONS.

6. ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE,

COMPUTER, ETC.) IN FIRE RATED WALLS OR CEILINGS SHALL BE

CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.

7. OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) ON OPPOSITE

SIDES OF FIRE RATED WALLS SHALL BE SEPARATED BY A HORIZONTAL

DISTANCE OF 24 INCHES OR PROTECTED BY OTHER MEANS ALLOWED BY

THE SPECIFIC U.L. ASSEMBLY.

8. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF STC RATED

WALLS. OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) ON

OPPOSITE SIDES OF STC RATED WALLS SHALL BE LIMITED TO TWO OUTLET

BOXES PER STUD SPACE AND COVERED WITH "PUTTY PAD" TYPE

MOLDABLE FIRE BARRIER.

9. FIELD VERIFY THE EXACT LOCATION OF ALL FLOOR BOXES AND POKE

THROUGHS WITH ARCHITECT PRIOR TO ROUGH-IN.

10. THE FIRE ALARM SYSTEM SHOWN HAS BEEN DESIGNED PER THE

REQUIREMENTS OF NFPA 72. DEVICES SHOWN INDICATE THE DESIGN

INTENT AND SHALL BE THE MINIMUM PROVIDED. SYSTEM SUPPLIER SHALL

PROVIDE ANY ADDITIONAL CODE REQUIRED DEVICES OR DEVICES

REQUIRED BY THE AUTHORITY HAVING JURISDICTION.

11. ALL DATA CABLING SHALL BE CAT. 6A WITH BLUE COLORED JACKET. VERIFY

WITH OWNER PRIOR TO INSTALLATION.

OFFICE

OFFICE

OFFICE

COFFEE

SCANNER/MAIL

PROCESSING

RECORDS ROOM

SUPPLY ROOM

RETURN MEDS ROOM

(E) HSK

(E) SWITCH ROOM

CUBICLES

CORRIDOR

HALLWAY

HALLWAY

(E) COMPUTER TRAINING

(E) GROUP FITNESS

(E) STOR

(E) WORKOUT ROOM

(E) WOMEN

(E) MEN

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OCCUPATIONAL HEALTH

(E) STORAGE

(E) STAIR

(E) ELEV. MACHINE

(E) STAIR

(E) OPEN SPACE

(E) ELEV

HOB-1

EXISTING 75kVA

TRANSFORMER

LOB-1

LOB-2

TX-LOB-2

VAV-16

VAV-14

VAV-13

VAV-17A

SF1

SF1

S1S1

LOB-2:1

LOB-2:3

LOB-2:5

LOB-2:7

LOB-2:9

LOB-2:11

LOB-2:13

LOB-2:17

LOB-2:15

LOB-2:37

LOB-2:21

LOB-2:23

LOB-2:25

LOB-2:27

LOB-2:31

LOB-2:33

LOB-2:35

COPIER

LOB-2:19

LOB-2:29

P1

P1

P1

P1 P1

P1

P2

P2

VAV-15

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

Dwg. of o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

KEYPLAN

AREA OF CONSTRUCTION

/2

/2

:0

:1

P

M B

IM

/1

R

A tr ia x

M u rf re e s b o ro C

M O

P /2

-0

E

L E

C R

.r v t

E-101

POWER & SYSTEMS PLAN MEDS BY MAIL OFFICE

EXPANSION AT THE

MID-SOUTH CMOP

3209 ELAM FARMS PKWY, MURFREESBORO, TN 67127

764-21-101

N/A

03/25/2022 DDC KTN 14 17

KEYED NOTES

P1 ACCESS CONTROL ROUGH-IN. VERIFY ALL SYSTEM REQUIREMENTS WITH

MANUFACTURER PRIOR TO ROUGH-IN. REFER TO DETAIL 8/E-501 FOR

ADDITIONAL INFORMATION.

P2 IF TAKING ALTERNATE #1, USE VAV-16A AND VAV-17A SCHEDULED DATA.

OTHERWISE, USE VAV-16 SCHEDULED DATA ONLY AND OMIT VAV-16A AND

VAV-17A.

S1 PROVIDE JUNCTION BOX AND CONDUIT ABOVE ACCESSIBLE CEILING FOR

SIX (6) CAT. 6A CABLES WITH BLUE COLORED JACKET FOR SYSTEMS

FURNITURE. VERIFY LOCATION AND ALL REQUIREMENTS WITH SYSTEMS

FURNITURE PRIOR TO ROUGH-IN.

0' 8' 12'4' 1/8" = 1'-0"

POWER & SYSTEMS PLAN

A

1D

1D 1D

1D 1D

1D

1D 1D

LIGHTING PLAN NOTES:

1. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS WITH

INDIVIDUAL NEUTRALS. A MAXIMUM OF THREE CIRCUITS (MAXIMUM OF

THREE PHASE CONDUCTORS) MAY BE GROUPED IN A SINGLE CONDUIT.

WHERE MULTIPLE CIRCUITS ARE LOCATED IN THE SAME RACEWAY,

JUNCTION BOX OR ENCLOSURE, NEUTRALS SHALL BE MARKED OR LABELED

TO INDICATE WHICH CIRCUIT THEY ARE ASSOCIATED WITH. SEE

SPECIFICATION SECTION "LOW VOLTAGE ELECTRICAL POWER CONDUCTORS

AND CABLES" FOR ADDITIONAL INFORMATION.

2. A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL

CONDUITS.

3. REFER TO THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR

LOCATIONS OF FIRE RATED WALLS AND CEILINGS AND THE ASSOCIATED U.L.

ASSEMBLY NUMBERS.

4. FOR ALL PENETRATIONS IN FIRE RATED WALLS AND CEILINGS, PROVIDE AN

ASTM E814 COMPLIANT, U.L. LISTED THROUGH PENETRATION FIRE

STOPPING SYSTEM THAT IS SPECIFIC TO THE WALL OR CEILING

CONSTRUCTION ASSEMBLY. INSTALL SYSTEM IN STRICT COMPLIANCE WITH

THE U.L. ASSEMBLY INDICATED IN THE ARCHITECTURAL DRAWINGS AND

SPECIFICATIONS.

5. ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE,

COMPUTER, ETC.) IN FIRE RATED WALLS OR CEILINGS SHALL BE

CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.

6. OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) ON OPPOSITE

SIDES OF FIRE RATED WALLS SHALL BE SEPARATED BY A HORIZONTAL

DISTANCE OF 24 INCHES OR PROTECTED BY OTHER MEANS ALLOWED BY

THE SPECIFIC U.L. ASSEMBLY.

7. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF STC RATED

WALLS. OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) ON

OPPOSITE SIDES OF STC RATED WALLS SHALL BE LIMITED TO TWO OUTLET

BOXES PER STUD SPACE AND COVERED WITH "PUTTY PAD" TYPE MOLDABLE

FIRE BARRIER.

8. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHT

FIXTURE LOCATIONS. VERIFY ALL DISCREPANCIES WITH ARCHITECT PRIOR

TO ROUGH-IN.

9. OCCUPANCY SENSORS SHALL MATCH EXISTING FACILITY STANDARDS.

VERIFY WITH OWNER PRIOR TO INSTALLATION.

OFFICE

OFFICE

OFFICE

COFFEE

SCANNER/MAIL

PROCESSING

RECORDS ROOM

SUPPLY ROOM

RETURN MEDS ROOM

(E) HSK

(E) SWITCH ROOM

CUBICLES

CORRIDOR

HALLWAY

HALLWAY

(E) COMPUTER TRAINING

(E) GROUP FITNESS

(E) STOR

(E) WORKOUT ROOM

(E) WOMEN

(E) MEN

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OFFICE

(E) OCCUPATIONAL HEALTH

(E) STORAGE

(E) STAIR

(E) ELEV. MACHINE

(E) STAIR

(E) OPEN SPACE

(E) ELEV

HOB-1

LOB-1

LOB-2

TX-LOB-2

EXISTING 75kVA

TRANSFORMER

K2 K2

K2 K2

K2K2

X1L3L3

L3 L3

K3 K3

L3 L3

K3

K3

K3 K3

K3

K3

X1

X1

K2 K2 K2 K2 K2 K2 K3

X1

X1

F4 F4 F4 F4

F4

K3 K3 K3 K3

K3K3

K3 K3

K3

K3HOB-1:12

HOB-1:14

L1

L2

L2

L2

L2

L2

X1

X1

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number:

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

Dwg. of o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Veterans Health

Administration GLMV Architecture Architect 1525 E. Douglas, Wichita, KS 67211

Phone: 316-265-9367 www.glmv.com

Professional Engineering Consultants (PEC) MEP Engineers 623 Massachusetts Street, Suite 200, Lawrence, KS 66044

Phone: 785-842-6464 www.pec1.com

Atriax, pllc 102 3rd Avenue NE, Hickory, NC 28601 PO Box 1629, Hickory, NC 28603

Phone: 828-315-9962 www.atriaxgroup.com

KEYPLAN

AREA OF CONSTRUCTION

/2

/2

:0

:1

P

M B

IM

/1

R

A tr ia x

M u rf re e s b o ro C

M O

P /2

-0

E

L E

C R

.r v t

E-102

LIGHTING PLAN MEDS BY MAIL OFFICE

EXPANSION AT THE

MID-SOUTH CMOP

3209 ELAM FARMS PKWY, MURFREESBORO, TN 67127

764-21-101

N/A

03/25/2022 DDC KTN 15 17

KEYED NOTES

L1 EXISTING WALL MOUNTED EXIT SIGN TO BE DEMOLISHED. INSTALL NEW

CEILING MOUNTED EXIT SIGN AS INDICATED.

L2 INTERLOCK OCCUPANCY SENSORS PER MANUFACTURER'S

REQUIREMENTS. ALL NEW SENSORS TO MATCH EXISTING

MANUFACTURER AND TYPE.

0' 8' 12'4' 1/8" = 1'-0"

LIGHTING PLAN

A

PANEL

HOB-1

TX-LOB-2

75 KVA

PANEL

LOB-2

(E) STORAGE 206

TO "EDP"6"(MIN.)

46" AFF TO CENTERLINE, TOP OF

DEVICE SHALL NOT BE MORE THAN 48" AFF

MAGNETIC HOLD OPEN

OR CLOSURE/HOLD

OPEN. COORDINATE

WITH HARDWARE

SPECIFICATIONS.

(TYP.)

DETECTOR

SMOKE

FIRE ALARM DEVICE MOUNTING CRITERIA

THESE GUIDELINES SHALL BE USED

UNLESS MOUNTING HEIGHTS HAVE BEEN

SPECIFIED OTHERWISE ON THE DRAWINGS.

GENERAL NOTE

PULL STATION

REFER TO THE VISUAL UNIT.

AUDIO/VISUAL UNIT

AUDIO UNIT

VISUAL UNIT

TOP OF DETECTOR

ACCEPTABLE HERE

DO NOT PLACE DETECTOR

IN THIS AREA

MAINTAIN 36" BETWEEN SMOKE DETECTOR

AND AIR DIFFUSER/REGISTER/GRILL

PULL

STATION

12" 4"

90"

80"

46"

AUDIO/VISUAL

80" TO BOTTOM

AUDIO ONLY

6"(MIN.)

6"(MIN.)

AUDIO ONLY

90" TO TOP

VISUAL ONLY

80" TO BOTTOM

FINISH FLOOR

CEILING

MAX. OF 5'-0", MIN. OF "d"

BUT NOT LESS THAN 12"

DETECTORS ON ONE SIDE

OR BOTH SIDES OF DOOR

AS REQUIRED BY NFPA 72.

HEIGHT OF

DOOR HEADER "d"

AIR DIFFUSER

TOP OF DEVICE 90"…