Flamingo Tower CD.pdf
PDF 2 MB Posted
- Attached to
- ACRx San Antonio and McAllen, Texas
- Solicitation number
- 15F06726Q0000448
About this file
This document is a set of construction drawings for a wireless facility enhancement project managed by Crown Castle USA Inc. for the Federal Bureau of Investigation.
The project scope involves enhancing broadband connectivity and capacity at an existing eligible wireless facility located at 1804 Flamingo Avenue, McAllen, Texas 78504 (Hidalgo County). The site features a 440-foot guyed tower owned and operated by OE Investments Inc., with property ownership held by Crown Castle. The project requires installation of one SitePro1-R5 Universal Pipe Mount Kit, one Radiowaves HP4-7.7 Microwave Dish, and two CommScope CNT-400 cables on the existing tower structure. All work must comply with current editions of applicable codes including the 2021 International Building Code, 2021 International Mechanical Code, and 2023 National Electrical Code with amendments, as adopted by the City of McAllen. The drawings package includes site plans, tower elevations, antenna plans, equipment details and specifications, and component-level installation documentation. Prior site access requires coordination with Crown Castle's Network Operations Center at (800) 788-7011 and the project's construction manager. The contractor is responsible for verifying all existing site conditions and dimensions and must immediately report discrepancies to the engineer before proceeding with work. Site coordinates are listed as 26° 15' 25.25" North latitude and -98° 13' 54.51" West longitude (NAD83 datum) with ground elevation at 114 feet southeast.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ 15F06726Q0000448.pdf | ||
| Santa Maria Tower CD.pdf | ||
| ACRx San Antonio.McAllen SOW.pdf | ||
| Olmito Tower CD.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NO SCALE
SITE INFORMATION
PROJECT TEAM
DRAWING INDEX LOCATION MAPPROJECT DESCRIPTION
APPLICABLE CODES &
REFERENCE DOCUMENTS
CARRIER/APPLICANT:
AMERICAN ELECTRIC POWER
(800) 277-2177
ELECTRIC PROVIDER:
U
IIB
FACILITY IS UNMANNED AND
NOT FOR HUMAN HABITATION
OCCUPANCY CLASSIFICATION:
TYPE OF CONSTRUCTION:
A.D.A. COMPLIANCE:
AREA OF CONSTRUCTION:
CURRENT ZONING:
MAP/PARCEL #:
CUP/LIFE OF USE PERMIT 08/14/2000
H0850-00-001-0014-10
PROPERTY OWNER:
CROWN CASTLE
2000 CORPORATE DRIVE
CANONSBURG, PA 15317
TOWER OWNER/OPERATOR:
O E INVESTMENTS INC
PO BOX 4408
MCALLEN, TX 78502-4408
LATITUDE:
LONGITUDE:
LAT/LONG TYPE:
GROUND ELEVATION:
JURISDICTION: CITY OF MCALLEN, TX
311 N. 15TH STREET
MCALLEN, TX 78501
CROWN CASTLE USA INC.
SITE NAME:
BU NUMBER:
MTC 1
881455
1804 FLAMINGO AVESITE ADDRESS:
COUNTY:
26° 15' 25.25" / 26.257014° -98° 13' 54.51" / -98.231808°
NAD83
114' SE
STRUCTURAL ANALYSIS:
DATED:
BY OTHERS
N/A
REFERENCE DOCUMENTS:
MOUNT ANALYSIS:
DATED:
BY OTHERS
N/A
RFDS REVISION:
DATED:
BY OTHERS
N/A
ORDER ID:
REVISION:
728484
PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE
CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER.
ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17.
CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS
AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY
THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE
PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.
FBI FEDERAL BUREAU OF INVESTIGATION SITE NUMBER:
FBI FEDERAL BUREAU OF INVESTIGATION SITE NAME:
FBI FEDERAL BUREAU OF INVESTIGATION PROJECT:
BUSINESS UNIT #:
SITE ADDRESS:
COUNTY:
SITE TYPE:
TOWER HEIGHT:
881455--
MTC 1
1804 FLAMINGO AVE
MCALLEN, TX 78504
HIDALGO
GUYED TOWER
440'-0"
MCALLEN, TX 78504
HIDALGO
THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND
CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE
WIRELESS FACILITY.
FBI FEDERAL BUREAU OF
INVESTIGATION
935 PENSYLVANIA AVE
WASHINGTON, DC 20535
SHEET # SHEET DESCRIPTION
CALL TEXAS ONE CALL
(800) DIG-TESS
CALL 3 WORKING DAYS
BEFORE YOU DIG!
A&E FIRM:
CROWN CASTLE 2000 CORPORATE DRIVE
CANONSBURG, PA 15317
CROWN CASTLE USA INC.
2000 CORPORATE DRIVE
CANONSBURG, PA 15317
CONTACTS:
DIRECTIONS
MARIA GUZMAN - PROJECT MANAGER
MARIA.GUZMAN@CROWNCASTLE.COM
RICHARD MCCLURE - AES
RICHARD MCCLURE@CROWNCASTLE.COM
T-1 TITLE SHEET
T-2 GENERAL NOTES
C-1 SITE PLAN
C-2 TOWER ELEVATIONS
C-3 ANTENNA PLANS
C-4 EQUIPMENT DETAILS AND SPECIFICATIONS
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING
CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.
NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK
NOT CONFORMING TO THESE CODES:
CODE TYPE CODE
BUILDING 2021 IBC
MECHANICAL 2021 IMC
ELECTRICAL 2023 NEC W/ AMENDMENTS
TOWER SCOPE OF WORK:
• INSTALL (1) SITEPRO1 - R5 UNIVERSAL PIPE MOUNT KIT
• INSTALL (1) RADIOWAVES - HP4-7.7 MICROWAVE DISH
• INSTALL (2) COMMSCOPE - CNT-400 CABLES
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
0T-1
REVISION:SHEET NUMBER:
ISSUED FOR:
DRWNREV DESCRIPTION DES./QADATE
C R
O W
N G
E N
E R
IC
.7
.0
FBI FEDERAL BUREAU OF
INVESTIGATION
SITE NUMBER: --
BU #: 881455
CROWN CASTLE SITE NAME
MTC 1
1804 FLAMINGO AVE
MCALLEN, TX 78504
EXISTING 440'-0"
GUYED TOWER
0 04/10/26 KRW MACONSTRUCTION
CROWN CASTLE USA INC.
COA #F-9989
ATTACHED MOUNT SPECIFICATIONS (BY OTHERS)
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
0T-2
REVISION:SHEET NUMBER:
ISSUED FOR:
DRWNREV DESCRIPTION DES./QADATE
C R
O W
N G
E N
E R
IC
.7
.0
FBI FEDERAL BUREAU OF
INVESTIGATION
SITE NUMBER: --
BU #: 881455
CROWN CASTLE SITE NAME
MTC 1
1804 FLAMINGO AVE
MCALLEN, TX 78504
EXISTING 440'-0"
GUYED TOWER
0 04/10/26 KRW MACONSTRUCTION
CROWN CASTLE USA INC.
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
0C-1
REVISION:SHEET NUMBER:
ISSUED FOR:
DRWNREV DESCRIPTION DES./QADATE
C R
O W
N G
E N
E R
IC
.7
.0
FBI FEDERAL BUREAU OF
INVESTIGATION
SITE NUMBER: --
BU #: 881455
CROWN CASTLE SITE NAME
MTC 1
1804 FLAMINGO AVE
MCALLEN, TX 78504
EXISTING 440'-0"
GUYED TOWER
0 04/10/26 KRW MACONSTRUCTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
0C-2
REVISION:SHEET NUMBER:
ISSUED FOR:
DRWNREV DESCRIPTION DES./QADATE
C R
O W
N G
E N
E R
IC
.7
.0
FBI FEDERAL BUREAU OF
INVESTIGATION
SITE NUMBER: --
BU #: 881455
CROWN CASTLE SITE NAME
MTC 1
1804 FLAMINGO AVE
MCALLEN, TX 78504
EXISTING 440'-0"
GUYED TOWER
0 04/10/26 KRW MACONSTRUCTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
0C-3
REVISION:SHEET NUMBER:
ISSUED FOR:
DRWNREV DESCRIPTION DES./QADATE
C R
O W
N G
E N
E R
IC
.7
.0
FBI FEDERAL BUREAU OF
INVESTIGATION
SITE NUMBER: --
BU #: 881455
CROWN CASTLE SITE NAME
MTC 1
1804 FLAMINGO AVE
MCALLEN, TX 78504
EXISTING 440'-0"
GUYED TOWER
0 04/10/26 KRW MACONSTRUCTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
0C-4
REVISION:SHEET NUMBER:
ISSUED FOR:
DRWNREV DESCRIPTION DES./QADATE
C R
O W
N G
E N
E R
IC
.7
.0
FBI FEDERAL BUREAU OF
INVESTIGATION
SITE NUMBER: --
BU #: 881455
CROWN CASTLE SITE NAME
MTC 1
1804 FLAMINGO AVE
MCALLEN, TX 78504
EXISTING 440'-0"
GUYED TOWER
0 04/10/26 KRW MACONSTRUCTION
CROWN CASTLE USA INC.
MICROWAVE SPECS
DETAIL A
PARTS LIST
NET WT.UNIT WT.LENGTHPART DESCRIPTIONPART NO.QTYITEM
21.0310.5216 11/32 inUNIVERSAL PIPE MOUNTING PLATE (INNER)X-15446321
26.3113.1620 9/32 inUNIVERSAL PIPE MOUNTING PLATE (OUTER)X-15556122
11.465.736 9/16 inBACKING PLATEX-15999923
1.080.27 5/8" x 2" HDG HEX BOLT GR5 G580244
0.280.071/8 in5/8" HDG USS FLATWASHERG58FW45
0.100.035/32 in5/8" HDG LOCKWASHERG58LW46
0.520.135/8 in5/8'' HDG HEAVY 2H HEX NUTG58NUT47
64.8964.89 4-1/2" X 72" SCH. 40 GALVANIZED PIPEP47218
3.890.97 1/2" X 4-5/8" X 7" X 3" GALV U-BOLTX-UB145849
2.160.274 in1/2'' x 4" HDG HEX BOLT GR5 FULL THREADG1204810
3.280.416 1/2 in1/2'' x 6-1/2" HDG HEX BOLT GR5 FULL THREADG12065810
0.550.033/32 in1/2" HDG USS FLATWASHERG12FW1611
0.220.011/8 in1/2" HDG LOCKWASHERG12LW1612
1.150.07 1/2'' HDG HEAVY 2H HEX NUTG12NUT1613
A
DESCRIPTION
DRAWING USAGE CHECKED BY
ENG. APPROVALDRAWN BY
DWG. NO.
CPD NO.
RH18
O
F
BMC 11/12/2015
3/29/2010 R5
R5 UNIVERSAL PIPE MOUNT KIT
WITH 4-1/2" PIPE
CUSTOMER R5
CLASS SUB
PART NO.
81 01
P A
G E
TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:
SAWED, SHEARED AND GAS CUT EDGES (± 0.030")
DRILLED AND GAS CUT HOLES (± 0.030") - NO CONING OF HOLES
LASER CUT EDGES AND HOLES (± 0.010") - NO CONING OF HOLES
BENDS ARE ± 1/2 DEGREE
ALL OTHER MACHINING (± 0.030")
ALL OTHER ASSEMBLY (± 0.060")
TOLERANCE NOTES
PROPRIETARY NOTE:
THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONT INDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OF
VALMONT INDUSTRIES IS STRICTLY PROHIBITED.
Engineering Support Team:
1-888-753-7446 valmont
Locations:
New York, NY Atlanta, GA Los Angeles, CA Plymouth, IN Salem, OR Dallas, TX
TOTAL WT. # 136.92
13121110
9 11 12 13
TOWER LEG,
1-1/2" to 4-1/2" O.D. MEMBERS
TAPER NOTE:
THE MAXIMUM TAPER ADJUSTMENT IS 5.7° BASED UPON
30" SPACING OF ADJUSTABLE MOUNTING BRACKETS.
THE MAXIMUM TAPER ADJUSTMENT IS 3.8° BASED UPON
45" SPACING OF ADJUSTABLE MOUNTING BRACKET.
| Sheets and Views |
| 881455_728484-T-1 |
| 881455_728484-T-2 |
| 881455_728484-C-1 |
| 881455_728484-C-2 |
| 881455_728484-C-3 |
| 881455_728484-C-4 |
| 2026-04-10T14:48:44-0500 | |
| Morteza Ashouri |
| 2026-04-10T14:48:44-0500 | |
| Morteza Ashouri |
| 2026-04-10T14:48:44-0500 | |
| Morteza Ashouri |
| 2026-04-10T14:48:44-0500 | |
| Morteza Ashouri |
| 2026-04-10T14:48:45-0500 | |
| Morteza Ashouri |
| 2026-04-10T14:48:45-0500 | |
| Morteza Ashouri |
File details come from the government source that posted it. Updated .