Flagler_County_-_Multipurpose_-_Building_Layout.pdf
PDF 447 KB Posted
- Solicitation number
- 25-RSQ-079
- Issued by
- Glades County, Brownsville CDP, Florida
About this file
This is a floor plan drawing for Flagler County's Multipurpose Emergency Preparedness Facility, a 10,006 square foot main multipurpose space designed to serve as a Category 5 hurricane-capable community storm shelter. The facility layout includes multiple functional areas: a 523 square foot kitchen, women's and men's restrooms (260 and 261 square feet respectively), five shower areas (81 square feet each), a 513 square foot lobby, three storage areas totaling 2,252 square feet, a 453 square foot mechanical room, custodial spaces, electrical and data rooms, a vestibule, panel storage, and an equipment yard. The building measures 152 feet 8 inches in length with various bay widths of 25 feet and 26 feet 4 inches. The design incorporates accessible features including an electric water cooler and clearly marked door and window schedules. The building is designed to accommodate emergency preparedness functions with equipment for cots, medical beds, round tables and chairs, cot storage racks, and animal kennels as indicated on the plan. The floor plan is preliminary and not for construction, prepared by R. Dean Scott, Architect, Inc., with a project number of D-25-04 and dated June 27, 2025.
The drawing serves as supporting documentation for Flagler County's Request for Statements of Qualifications for Construction, Engineering & Inspection services for this design-build project. Proposals for CEI services are due September 4, 2025, at 3:00 PM, with evaluation committee meetings scheduled for the week of September 8, 2025, and firm presentations the week of September 15, 2025. CEI services will include pay application certification, quality assurance, inspection, materials sampling and testing, monitoring, plan and schedule reviews, progress meetings, and reporting. The county will contract with one firm on an as-needed basis with compensation negotiated individually using either lump-sum or cost-plus-not-to-exceed formats. Selected firms must maintain commercial general liability insurance of $2,000,000 aggregate, professional liability of $1,000,000 per claim, workers' compensation, and automobile liability of $1,000,000 combined single limit. The contract term is anticipated to be three years with the possibility of two additional two-year extensions, not exceeding seven years total. All personnel must be properly licensed in Florida with appropriate certifications.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ACCESSIBLE ELECTRIC WATER COOLER
DOOR SYMBOL - REFER TO DOOR SCHEDULE
WINDOW SYMBOL - REFER TO WINDOW SCHEDULE
WALL TYPE SYMBOL - REFER TO WALL SECTIONS
EXTERIOR WALL
INTERIOR PARTITION
A
FLOOR PLAN KEY:
EWC
1i
A081
A07
A08
A07
A09
498 SF
STORAGE 3
453 SF
MECHANICAL
877 SF
STORAGE 2
260 SF
WOMEN'S
RESTROOM
10006 SF
MULTIPURPOSE
513 SF
LOBBY
877 SF
STORAGE 1
81 SF
SHOWER 2
39 SF
CUSTODIAL 1
81 SF
SHOWER 1
81 SF
SHOWER 3
81 SF
SHOWER 4
40 SF
CUSTODIAL 2
261 SF
MEN'S
RESTROOM
A09
A14
GENERATOR
73 SF
SHOWER 5
H Y
D R
O P
N E
U M
A T
IC
T A
N K
523 SF
KITCHEN
90 SF
ELECTRICAL
79 SF
DATA
48 SF
CUSTODIAL 3
81 SF
VESTIBULE
60 SF
PANEL
STORAGE
0.1
0.1
AA
FF
DD
CC
BB
EE
7.9
7.9
152'-8"
1'-4" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 26'-4" 35'-4"
A11
A11
A11
EQUIPMENT
YARD
EWC EWC
SHELTER COT, TYPICAL MEDICAL BED, TYPICALROUND TABLE AND
CHAIRS, TYPICAL
COT STORAGE RACK,
TYPICAL
ANIMAL KENNEL,
TYPICAL
FLAGLER COUNTY
C O P Y R I G H T 2 0 2 5
R . D E A N S C O T T , A R C H I T E C T , I N C .
A L L R I G H T S R E S E R V E D .
T H E S E D R A W I N G S & S P E C I F I C A T I O N S
A R E I N S T R U M E N T S O F S E R V I C E A N D
S H A L L R E M A I N P R O P E R T Y O F
R . D E A N S C O T T , A R C H I T E C T , I N C .
A N D S H A L L N O T B E U S E D
F O R A N Y O T H E R P R O J E C T O R
F O R A N E X T E N S I O N O F T H I S
P R O J E C T W I T H O U T E X P R E S S
W R I T T E N C O N S E N T O F
R . D E A N S C O T T , A R C H I T E C T , I N C .
SEAL
AR 0014890
R. DEAN SCOTT, AIA
DRAWN BY:
NO.
CHECKED BY:
REVISION
JUNE 27, 2025
PREP BY
DATE:
DATE
SNF RDS
P R E L
IM
IN
A R Y N O T
F O R
C O N S T R U C T
IO
N
A L L
S H E E T S
OF 30 A SHEETS
DRAWING NO.
MULTIPURPOSE EMERGENCY PREPAREDNESS FACILITY
RDSA PROJECT NO. D-25-04
BUNNELL, FLORIDA 32110
150 SAWGRASS ROAD
J A C K S O N V I L L E
T E L E P H O N E
F A C S I M I L E
W E B S I T E
L I C E N S E N U M B E R
F L O R I D A 3 2 2 0 2
9 0 4 - 5 9 8 - 0 0 7 2
9 0 4 - 5 9 8 - 0 4 5 0
W W W . R D E A N S C O T T . C O M
A R 0 0 1 4 8 9 0
1 2 6 W . A D A M S S T R E E T S U I T E 6 0 2
:2 :1
P M
C U s e rs S F o lk e rs D o c u m e n ts F la g le r C o u n ty
M u lt ip u rp o s e
.0 .2
R V T s fo lk e rs K S V R L .r v t
A02FLOOR PLAN
1. REFER TO SHEET G02 FOR GENERAL NOTES.
2. REFER TO SHEET A03 FOR DIMENSIONS AND COLUMN DESIGNATIONS.
3. REFER TO SHEET A06 FOR EQUIPMENT.
FLOOR PLAN GENERAL NOTES:
PLAN
W
E
NS
1/8" = 1'-0"1
FLOOR PLAN
File details come from the government source that posted it. Updated .