Fish System Specification Sheet.pdf
PDF 102 KB Posted
- Attached to
- Aquarium System Federal contract opportunity
- Solicitation number
- NIH_OD1_NOI160523006
About this file
This document outlines specifications for an aquarium system and details a federal contract opportunity notice. The National Institutes of Health (NIH) intends to solicit proposals for an additional aquarium system to house zebrafish for research conducted by the Section on Sensory Cell Development and Function. The system must include multi-rack tanks, monitoring instrumentation, temperature control, and automated water quality parameters. Capability statements are due by May 31, 2023 and should not include pricing. The contract will have a one-year base period to provide a complete aquarium system according to the specifications for zebrafish research at NIH.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Justification-and-Approval-for-Sole-Source_Kindt_AEI_2023 lp for lc sig-4 - LK.pdf | ||
| Standard Form 1449 - Solicitation_Contract_Order for Commercial Products and Commercial Services.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fish System Specifications
Multi-rack Fish System: Powdercoated Aluminum Racks: 55”L x 17.5”W x 92”H (set of 2)
Powdercoated Aluminum Racks: 46”L x 17.5”W x 92”H
Each rack:
• should come complete with manifolds, valves, sump with built-in biofilters, gutters, downspouts stainless rinse and reuse prefilters and all associated plumbing connection.
• should be fully welded type 6063 structural aluminum with barrier coating.
• should be able to hold up to sixty (60) 4-liter tanks, thirty (30) 8-liter tanks ninety (90) 2-liter tanks or a combination of each.
• should allow the user to be able to change the tank locations at any time without rack modifications.
• Should have integrated leveling feet.
• Should provide precision flow control valves to each tank.
• Should have high quality true-union ball vales at each shelf for easy flow control for the whole rack.
• Should not allow for any tanks to sit outside the rack foot-print, insuring no accidental tank dislocation.
• Should come with a main valve that can be used to turn off flow to the rack without affecting the rest of the system.
Tanks: 2L Polycarbonate Tanks with Lids and Baffles (Qty. 940)
4L Polycarbonate Tanks with Lids and Baffles (Qty. 630)
Each tank:
• Should fit on any shelf on any rack in the system.
• Should provide a maximum self-cleaning effect through gravity and hydraulic action.
• Have baffles that promote self-cleaning and prevent clogs and overflows.
• Should be able to be easily removed while maintaining flow rates.
Life Support Systems:
• Should allow for a minimum of 6 complete cycles of water per hour.
• Should be quiet and mitigate the occurrence of gas bubble disease.
• Should have filters that remove waste down to 40 microns, as well as be self-cleaning.
• Should possess high-efficiency water pumps and a UV sterilizer (>120,000 uWatts/sec/CM2 kill rate at end of lamp life)
• Should have a automatic water change system and heater.
• Should include 4-stage filtration.
Monitoring & Controlling:
• Should have continuous monitoring of critical water chemistry parameters.
• Should be able to automatically control pH, conductivity and temperature.
• Should provide instant notification of potential water chemistry problems.
• Should have visual and audible alarms and alerts on controller.
• Should have a wi-fi connected monitoring system, with touchscreen tablet pH probe, conductivity probe, temperature probe, level sensor and two dosing pumps.
• Should provide 2 stock solution tanks and water test kit.