Final_RFB_785_2600000566_1_SO_FORM.PDF

PDF 280 KB Posted

Attached to
RFB-249-26 DJJ-Campbell Chiller Replacement
Solicitation number
RFB 785 2600000566 1
Issued by
Campbell County, Kentucky

About this file

This is a Request for Bid (RFB) document issued by the Commonwealth of Kentucky's Division of Engineering and Contract Administration on behalf of the Department of Juvenile Justice for chiller replacement services at the Campbell County Youth Development Center in Newport, Kentucky. The project involves the complete removal and replacement of the existing chiller and chilled water system in accordance with the International Mechanical Code, ASHRAE, Kentucky Building Code, Americans with Disabilities Act, International Building Code, and National Electrical Code. The scope of work includes disconnecting and removing the existing chiller, providing temporary chilling capability during replacement, and installing a new microprocessor-controlled, multiple-scroll compressor, air-cooled chiller with associated electrical power, control connections, and chilled water connections. The contractor must also handle legal and lawful disposal of the existing chiller, including refrigerant recovery and recycling. A mandatory site visit is scheduled for May 11, 2026, at 11:00 A.M. Eastern Time at 590 Columbia Street, Newport, KY 41071. The bid closes on May 28, 2026, at 1:30 P.M., with a public bid reading by conference call at 3:00 P.M. on the same date. The preferred work schedule is Monday through Friday, 8 hours per day, with a required 48-hour notification for any utility outages.

Bidders must submit responses exclusively through the Commonwealth's eProcurement system; postal, email, and hand-delivered bids will not be accepted. All bidders must be registered in the Vendor Self Service (VSS) System at https://vss.ky.gov prior to submission, with registration typically requiring 24 to 48 hours. The Official Bid Document and any required Bid Bond must be combined as a single PDF and uploaded through the eProcurement system. Plan and specifications are available for download at https://www.stateofkyplanroom.com at no charge, with hard copies available for purchase. Key project contacts include Engineer Grant Wilson (E-Tech Consultants, PLLC), Project Manager Greg Schenck, Agency Representative Brian Wiesman (Department of Juvenile Justice), and Purchasing Agent Janis Wilhoite. All procurement questions must be directed to Janis Wilhoite at 502-782-3926 or janis.wilhoite@ky.gov. The document does not specify contract award dates, contract term, pricing information, or any set-asides for specific bidder categories.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Document ID: RFB 785 2600000566 Page: 1

Commonwealth of Kentucky

SOLICITATION

Modification: No Version #:

TITLE: RFB-249-26 DJJ-Campbell Chiller Replacement

Date Issued:

04/29/2026 Record Date:

04/29/2026

Solicitation Closes Date:

05/28/2026 Time:

13:30

Solicitation No:

RFB 785 2600000566

Online Bidding Prohibited: No

For Information Call:

Janis Wilhoite 502-782-3926

Bid Receiving Location:

Bid Receiving

See Terms & Conditions for Bid Submission Instructions

Other KY

Vendor Customer Number:

Vendor Name:

Phone Number:

Fax Number:

Email Address:

Ordering

Address:

City, State, Zip:

Contact Name:

Contact Email:

Contact Phone Number:

Payment

Address:

City, State, Zip:

Contact Name:

Contact Email:

Contact Phone Number:

Ownership Type

__ Sole Proprietorship __ Partnership __ Corporation __ Other_________________________

SIGNATURE OF AUTHORIZED AGENT IS REQUIRED UNLESS RESPONSE

IS SUBMITTED ELECTRONICALLY. FAILURE TO SIGN SHALL RENDER

THE BID INVALID.

Signature X_________________________________________ FEIN#____________________ Date____________

All offers subject to all terms and conditions contained in this solicitation.

Document ID: RFB 785 2600000566 Page: 2

Line Items

Commodity Group: Default

Line CL Description Quantity UOM Unit Cost Line Total or Contract Amnt

1 RFB-249-26 DJJ-Campbell Chiller Replacement

Comm Code Comm Description Manufacturer Model # Manuf Part #

912 CONSTRUCTION SERVICES, GENERAL

(INCL. MAINTENANCE AND REPAIR

Extended Description

***ONLY ONLINE BIDS WILL BE ACCEPTED FOR THIS RFB.***

Emailed and hard copies delivered by any method WILL NOT BE ACCEPTED.

On this line, Bidders must enter $0.00 for Contract Amount in the e-procurement system. Actual Contract Amount must be entered on "Official Bid Document" and submitted as an attachment in the e-procurement system. Vendors should review and update, if necessary, all addresses and contact persons for their account prior to bid submission. This information will carry forward to a contract if awarded, therefore please ensure all information is correct.

** Entire Official Bid Document and Bid Bond (if required) should be combined as one PDF and uploaded**

The Contractor shall provide all of the materials and perform all the work described in the Specifications and/or shown on the Drawings. The Chiller and Chilled Water System of the CAMPBELL CO YDC Facility will be removed and replaced per the International Mechanical Code, ASHRAE, Kentucky Building Code with Current Revisions, Americans with Disabilities Act, International Building Code, and National Electrical Code.

The Contractor shall remove and take ownership of the existing chiller. The contractor shall disconnect the existing chiller from power and control and, disconnect the existing chiller from piping and mounting. Remove the existing chiller from its installed location and make the location ready for the new chiller described in the following. Make legal and lawful disposal of the chiller, which involves recycling of the unit beginning with refrigerant recovery and dismantling of the assembly for recycling or other appropriate disposition.

The Contractor shall provide a temporary Chiller while the existing Chiller is removed and a new Chiller including the Microprocessor controlled, multiple-scroll compressor, air-cooled, chiller of the scheduled capacities as shown and indicated on the Drawings, including but not limited to: chiller package, electrical power and control connections, and chilled water connections.

The Owners preferred daily work schedule shall be Monday-Friday 8 hour/day. There are no Contractor working days on Saturday-Sunday. A 48 hour notification is required for any outage of any existing utility including the Chilled Water and Heating Water Systems. Any damaged utility by the Contractor must be put back into service immediately.

Shipping Information Finance - Division of Engineering & Contract Administration

The Bush Building, 403 Wapping St 1st Floor

Frankfort KY 40601

Billing Information Finance - Division of Engineering & Contract Administration

The Bush Building, 403 Wapping St 1st Floor

Frankfort KY 40601

Document ID: RFB 785 2600000566 Page: 3

Submission Checklist

The following items will be required to be submitted with bid:

Item

REQUEST FOR BID NO. RFB-249-26

Chiller Replacement Department of Juvenile Justice Campbell County Youth Development Center Newport, Kentucky

Project Description

The Contractor shall provide all of the materials and perform all the work described in the Specifications and/ or shown on the Drawings. The Chiller and Chilled Water System of the CAMPBELL CO YDC Facility will be removed and replaced per the International Mechanical Code, ASHRAE, Kentucky Building Code with Current Revisions, Americans with Disabilities Act, International Building Code, and National Electrical Code.

The Contractor shall remove and take ownership of the existing chiller. The contractor shall disconnect the existing chiller from power and control and, disconnect the existing chiller from piping and mounting. Remove the existing chiller from its installed location and make the location ready for the new chiller described in the following. Make legal and lawful disposal of the chiller, which involves recycling of the unit beginning with refrigerant recovery and dismantling of the assembly for recycling or other appropriate disposition.

The Contractor shall provide a temporary Chiller while the existing Chiller is removed and a new Chiller including the Microprocessor controlled, multiple-scroll compressor, air-cooled, chiller of the scheduled capacities as shown and indicated on the Drawings, including but not limited to: chiller package, electrical power and control connections, and chilled water connections.

The Owner’s preferred daily work schedule shall be Monday-Friday 8 hour/day. There are no Contractor working days on Saturday-Sunday. A 48 hour notification is required for any outage of any existing utility including the Chilled Water and Heating Water Systems. Any damaged utility by the Contractor must be put back into service immediately.

SITE VISIT INFORMATION:

There will be a site visit on this project. Interested contractors are encouraged to attend. The site visit will be held on 5/11/2026 at 11:00 A.M. Eastern Time. The site visit will be held at 590 Columbia Street, Newport, KY 41071.

Upon arrival contractors will meet in the side parking lot near the Chiller and Mechanical Room.

ALL PROCUREMENT QUESTIONS SHALL BE DIRECTED TO BUYER OF RECORD FOR THIS

PROJECT.

IMPORTANT: Site visit participants shall follow any applicable health and safety guidelines for all Commonwealth of Kentucky construction projects.

PROJECT CONTACTS:

Engineer: Grant Wilson, E-Tech Consultants, PLLC, grant@e-techconsultants.com, (859) 321-3216 Project Manager: Greg Schenck, Division of Engineering and Contract Administration, Greg.Schenck@ky.gov,

(502) 234-0519 Agency: Brian Wiesman, Department of Juvenile Justice, BrianL.Weisman@ky.gov, (502) 229-0299 Purchasing Agent: Janis Wilhoite, Division of Engineering and Contract Administration, janis.wilhoite@ky.gov,

(502) 401-6239

OBTAINING PLANS AND SPECIFICATIONS:

Document Phase Document Description Page 4

2600000566 Final RFB-249-26 DJJ-Campbell Chiller Replacement Total Pages: 5

For all project information and documents go to: https://www.stateofkyplanroom.com. For customer service you may contact Lynn Imaging, Phone 1-800-888-0693. There is no charge for plans and specifications. Contractor will need to download bid documents, specifications, and drawings. If contractors want a hard copy, they can choose to pay for this option. Contractors that receive plans and specifications from other sources will not be registered as a planholder and will not receive addenda.

ELECTRONIC BID SUBMITTAL:

Solicitation responses (“bid”) shall be received by electronic submission through the Commonwealth’s eProcurement system.

Please be advised: Bids shall not be accepted via postal carrier (USPS, UPS, FED EX, etc.) nor can bids be hand delivered.

Response must contain all information required by the Solicitation and be executed by an authorized agent of the Bidder, affirmed by electronically submitting the bid through the eProcurement system. All bid documents shall be complete when the bid is submitted.

To bid, all bidders SHALL be registered in the Commonwealth eProcurement System via the Vendor Self Service (VSS) System at https://vss.ky.gov . Allow 24 – 48 hours to complete Vendor Registration. Vendors must be logged in to their Vendor Self Service account to submit a response. The Customer Resource Center is not able to complete registrations and activate accounts on the same day. Closing dates will not be extended for Vendors not registered by the date/time of the bid closing. Vendor Self Registration Guides are provided at https://vss.ky.gov under “Download Vendor Forms and Quick Reference Guides.”

All bidders are cautioned to begin their electronic submission in sufficient time to complete before the closing date and time. Delays due to inability to register, document upload impediments, or technical difficulties shall not be justification for acceptance of a late bid or proposal. If you need assistance, please contact the

Customer Resource Center (CRC)

- Email at Finance.CRCGroup@ky.gov;

- Locally at 502-564-9641 or toll-free 877-973- HELP (4357).

Online bid responses must be in an “Accepted” status prior to the closing date and time of the solicitation. The assigned date and time stamp from the eProcurement system generated at the time of final acceptance and formal submission by the vendor shall establish the date and time the bid was submitted. A bid may be modified or withdrawn electronically through VSS prior to the bid closing date and time.

Please be advised, VSS will not allow submission of an online response after the published date and time for closing.

Bidders shall attach the Official Bid Document and Bid Bond (if required) as a single combined attachment when submitting their electronic bids.

All results will be posted to https://www.stateofkyplanroom.com after the bid opening and review. If additional information is needed from the successful bidder, the buyer may be in contact.

There will be a public bid reading by conference call on the bid opening date at 3:00 P.M., Eastern Time.

The dial in number is (502) 782-2663 Conference ID# 240522124# Participant code is 600422#

Document Phase Document Description Page 5

2600000566 Final RFB-249-26 DJJ-Campbell Chiller Replacement Total Pages: 5 https://www.stateofkyplanroom.com https://vss.ky.gov/ https://vss.ky.gov/ mailto:Finance.CRCGroup@ky.gov https://www.stateofkyplanroom.com/

File details come from the government source that posted it. Updated .