Final Entrance Renovation Plans, December 23, 2020.pdf
PDF 1 MB Posted
- Solicitation number
- RFP BRIM 210000000609 2
- Issued by
- Cass County, Michigan
About this file
This is a set of final entrance renovation design plans for Secure Entrance Renovations at Brimley Area Schools in Brimley, Michigan, prepared by U.P. Engineers & Architects, Inc. and dated December 23, 2020. The project encompasses renovations to both the high school and elementary school entrances to implement security enhancements, including installation of bullet-resistant film on all glass surfaces (3M Scotchshield Ultra S800), new aluminum storefront doors and frames, removal and replacement of existing doors, relocation of electrical components, installation of access control systems, and new lighting fixtures. The renovation scope includes structural modifications such as the installation of steel joists with gypsum board on both sides, metal stud framing, and adjustments to existing acoustic ceiling grids. The plans contain detailed floor plans, elevation drawings, door and frame schedules, window specifications, and electrical plans showing locations for card readers, electric strikes, controllers, exit/emergency lighting, and a lockdown button system integrated with a master control panel.
The electrical work includes dedicated 120-volt circuits from existing panels, GFCI protection for relocated water cooler outlets, removal and relocation of existing switches and receptacles, and new emergency lighting systems. The project incorporates additive alternatives for door and electrical strike disconnection and reconnection work. The design plans specify that contractors verify all dimensions on-site and coordinate with other trades regarding clearances and equipment access. All electrical work must comply with the National Electrical Code, state electrical codes, and local municipal codes, with contractors responsible for obtaining necessary permits and delivering certificates of inspection upon completion. The plans indicate owner review dates of December 2 and December 18, 2020, with final issuance for the project documented as December 22, 2020.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
33 G5
30 65
17 139
55 52
CEDARVILLE
HESSEL
WHITEFISH
POINT
SAULT
STE
MARIE
NATIONAL PARK
ISLE ROYALE
NORWAY
MARENISCO
WHITE PINE
BERGLAND
NEWBERRY
SILVER
CITY
BESSEMER
IRONWOOD
WAKEFIELD
GREEN BAY
GWINN
HERMANSVILLE
MENOMINEE
IRON MOUNTAIN
VULCAN
CASPIAN
TROUT
WATERSMEET
CREEK
CROSSING
MASS
CITY
BRUCE
ONTONAGON
ROCKLAND BARAGA
ARNHEIM
CRYSTAL
FALLS
ISHPEMING
MICHIGAMME
L'ANSE
AURA
SKANEE
MARQUETTE
NEGAUNEE
MANISTIQUE
ESCANABA
FAYETTE
GARDEN
MUNISING
CURTIS
CITY
GOULD
HARBOR
CALUMET
RIPLEY
HOUGHTON
CHASSELL
HANCOCK
DELAWARE
LAKE
LINDEN
LAURIUM
EAGLE
HARBOR
COPPER
MACKINAC
ISLAND
IGNACE
ST
INDIAN
RIVER
CHEBOYGAN
MACKINAW CITY
PELSTON
ONAWAY
GAYLORD
PETOSKEY
CHARLEVOIX
MANCELONA
KALKASKA
TRAVERSE
CITY
EMPIRE
ELBERTA
ARCADIA
MANISTEE
SCOTTVILLE
BALDWINLUDINGTON
SHELBY
BIG RAPIDS
MOUNT
PLEASANT
CADILLAC
GRAYLING
EAST
TAWAS
ROSCOMMON
LACHINE ALPENA
WOLVERINE
ATLANTA
ROGERS CITY
ALANSON
CROSS
VILLAGE
BOYNE CITY
BELLAIRE
JORDAN
E.
EASTPORT
NORTHPORT
LELAND
BUCKLEY
FIFE
LAKE
FRANKFORT
MESICK
MANTON
BEAR
LAKE
LILLEY
HESPERIA
WHITE
CLOUD
EVART
REMUS
MIDLAND
SAGINAW
BAY
CITY
HARRISVILLE
CURRAN
MIO
OSCODA
TAWAS CITY
WEST
BRANCH
STANDISH
GLADWIN
McBAIN
LAKE CITY
CLARE
CARO
TROUT LAKE
BREVORT
IRON RIVERBRULE
WASHBURN
POPLAR
ASHLAND
PORT WING BAYFIELD
ODARRAH
MELLEN
UPSON
HURLEY
GLIDDEN
PARK FALLS
CLAM LAKE
MERCER
PRESQUE
ISLE
LAND O'LAKES
EAGLE
RIVER
PHELPS
FLORENCE
NIAGRA
CRANDON
SUPERIOR
HAYWARD
MINONG
CABLE
SHELL LAKE
GRANTSBURG
BALSAM
LAKE BARRON
MENOMONIE
DURAND
ALMA
WHITEHALL
BLACK
RIVER
FALLS
SPARTA
LA CROSSE
FRIENDSHIP
MONTELLO
WAUTOMA
GREEN
LAKE
FOND DU LAC
OSHKOSH
APPLETON
DE PERE
GREEN BAY
KEWAUNEE
STURGEON BAY
MARINETTE
OCONTO
SHAWANO
KESHENA
WAUSAU
STEVENS
POINT
WAUPACA
RHINELANDERPHILIPS
MEDFORD
MERRILL
ANTIGO
EAU CLARE
LADYSMITH
THREE
LAKES
MICHIGAN
WISCONSIN
LAKE
MICHIGAN
LAKE
SUPERIOR
HURON
LAKE
100 PORTAGE STREET
HOUGHTON, MI 49931
P (906) 482-4810 F (906) 482-9799
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
U.P. ENGINEERS &
ARCHITECTS, INC.
2906 N. STEPHENSON AVE, SUITE 2
IRON MOUNTAIN, MI 49801
P (906) 779-0937 F (906) 779-0947
424 S. PINE ST.
ISHPEMING, MI 49849
P (906) 485-1011 F (906) 485-1013
1701 DUNLAP AVE., SUITE 8
MARINETTE, WI 54143
P (715) 732-4188 F (715) 732-4189
707 ASHMUN STREET
SAULT STE. MARIE, MI 49783
P (906) 635-0511 F (906) 635-0612
PR
OJ
EC
T N
O:
w w w .u pe a.
co m
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
IS
SU
ED
F
O R:
D
AT
E:
Z:
\B
-0
B rim le y
Ar ea
S ch oo ls
-P ha se I
R en ov at io ns
\D w gs \B
-0
.rv t
/2
2/
:2 2:
P
M
SECURE ENTRANCE RENOVATIONS
BRIMLEY AREA SCHOOLS
BRIMLEY, MI
G001
COVER SHEET
SE
C
U R
E
EN
TR
AN
C E
R
EN
O
VA
TI
O
N S
B R
IM
LE
Y
AR
EA
S
C H
O O
LS
B
R
IM
LE
Y, M I
B7 0-
D C
JG JGD
C
SE
CU
RE
E
NT
RA
NC
E
RE
NO
VA
TI
O
NS
B R
IM
LE
Y
AR
EA
S
C H
O O
LS
SHEET INDEX
NUMBER SHEET NAME
G001 COVER SHEET
A101 HIGH SCHOOL ENTRANCE FLOOR PLAN
A102 ELEMENTARY ENTRANCE FLOOR PLAN & SCHEDULES
E001 ELECTRICAL ABBREVIATIONS
E101 ELECTRICAL PLAN
E501 ELECTRICAL DETAILS
PROJECT VICINITY
MAP
O W
NE
R
RE
VI
EW
/2 /2
O W
NE
R
RE
VI
EW
/1 8/
PROJECT LOCATION
BRIMLEY AREA PUBLIC SCHOOL
7134 M-221 BRIMLEY, MI 49715
OVERALL BUILDING FLOOR PLAN
N.T.S.
13' - 6"
OFFICE
RECEPTION
WORK
CLASSROOM
LOBBY
VEST.
WAITING
V.
I.F
8'
4"
DEMO EXISTING
CMU WALL & STOREFRONT
WINDOW (PREP OPENING
FOR NEW STOREFRONT)
DEMO EXISTING
DOOR. (FRAME
TO REMAIN)
DEMO EXISTING
ENTRANCE DOOR
(ADD ALTERNATE #1)
A101 A3
OFFICE
RECEPTION
WORK
CLASSROOM
LOBBY
VEST.
WAITING
V.
I.F
514.3
514.2
514.1
517.1
8'
4"
ADD ALTERNATE #1:
(REMOVE AND REPLACE
EXISTING DOORS)
515.1
515.2
515.3
FIRST FLOOR
100' - 0"
CEILING
110' - 0"
514 514.1 514.2 514.3 517.1
8'
8"
V.I.F.
14' - 0"
V.I.F.
8' - 4"
PROVIDE BULLET RESISTANT
FILM ON ALL GLASS,
EQUAL TO:
3M SCOTCHSHIELD ULTRA S800
A5 A101
AC
T
C
EI
LI
N
G 8'
8"
PROVIDE BULLET RESISTANT
FILM ON ALL GLASS,
EQUAL TO:
3M SCOTCHSHIELD ULTRA S800
(3) 10", 14 GAUGE STEEL
JOISTS W/ 5/8" GYP. EACH SIDE
FIRST FLOOR
100' - 0"
CEILING
110' - 0"
PROVIDE BULLET RESISTANT
FILM ON ALL EXISTING GLASS,
EQUAL TO:
3M SCOTCHSHIELD ULTRA S800
NEW STOREFRONT
DOOR IN EXISTING
FRAMED OPENING.
3' - 0" 3' - 0" 3' - 0"
C
EI
LI
N
G
(3) 10", 14 GAUGE
CSW STEEL JOIST
(BEAR ON (1) 6" METAL
STUD EA. END)
SECURE TO EXISTING
ROOF STRUCTURE
7'
0"
5/8" GYP. EACH SIDE
6" CSW 16 GAUGE
METAL STUDSMETAL TRACK
(TYP.)
1'
8"
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T N
O:
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R:
DA
TE
KEYPLAN
HIGH SCHOOL
ELEMENTARY
Z:
\B
-0
B rim le y
Ar ea
S ch oo ls
-P ha se I
R en ov at io ns
\D w gs \B
-0
.rv t
/2
2/
:2 2:
P
M
A101
HIGH SCHOOL
ENTRANCE FLOOR
PLAN
SE
C
U R
E
EN
TR
AN
C E
R
EN
O
VA
TI
O
N S
BR
IM
LE
Y
AR
EA
S
CH
OO
LS
En ter ad dr es s h er e
B7 0-
D C
JG JGD
C
SE
CU
RE
E
NT
RA
NC
E
RE
NO
VA
TI
O
NS
B R
IM
LE
Y
AR
EA
S
C H
O O
LS
3/16" = 1'-0"D1 HIGH SCHOOL ENTRANCE DEMO PLAN
3/16" = 1'-0"D3 PROPOSED HIGH SCHOOL ENTRANCE PLAN
1/4" = 1'-0"A3 HIGH SCHOOL ENTRANCE ELEVATION
1/4" = 1'-0"A2 WAITING RM ELEVATION
3/4" = 1'-0"A5 HIGH SCHOOL ENTRANCE DETAIL
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING AND BRACING
AND SHALL DISCUSS THEIR METHODS WITH THE ARCHITECT PRIOR TO THE
START OF WORK.
3. DO NOT SCALE THE DRAWINGS TO DETERMINE BUILDING DIMENSIONS.
MISCELLANEOUS:
O W
N
ER
R E V
IE
W
/2
/2
O
W N
ER
R
E V
IE
W
/1 8/
DEMO EXISTING
72"x48" FIXED WINDOW
(PREP OPENING FOR
PROPOSED DOOR)
DEMO EXISTING CMU
FOR PROPOSED DOOR
RECEPTION
VESTIBULE
OFFICE
CORRIDOR
REMOVE EXISTING ELECTRIC WATER
COOLER AND ASSOCIATED SANITARY
AND COLD WATER PIPING. PIPINT TO BE
REMOVED TO ABOVE CEILING AND
EXTENDED TO NEW LOCATION.
COORDINATE RELOCATION OF POWER
WITH ELECTRICAL PLANS.
DEMO EXISTING
DOOR
DEMO DOORS
(ADD ALTERNATE #2)
A102 A1
601.1
V.
I.F
" VESTIBULE
RECEPTION
OFFICE
CORRIDOR
REINSTALL SALVAGED ELECTRIC WATER
COOLER, EXTEND EXISTING SANITARY AND
1/2" CW PIPING TO PROPOSED LOCATION.
THE CONTRACTOR SHALL FIELD-VERIFY
LOCATION AND CONNECTION
REQUIREMENTS FOR EXISTING SYSTEM.
SANITARY PIPING SHALL BE SCHED-40 PVC
AND COLD WATER PIPING SHALL
BE TYPE-L COPPER.
A102
A3
V.I.F.
6' - 0"
ADD ALTERNATE #2:
(REMOVE AND REPLACE
EXISTING DOORS)
C5 A102
601.1 615
7'
1/
2"
AC
T
C
EI
LI
N
G 7'
7"
C M
U B
LO
C
K 8'
0"
PROVIDE BULLET RESISTANT
FILM ON ALL GLASS,
EQUAL TO:
3M SCOTCHSHIELD ULTRA S800
REMOVE AND REINSTALL ACT
CEILING GRID AS NECESSARY
FOR INSTALLATION OF STOREFRONT
RELOCATED
DRINKING
FOUNTAIN
C5 A102
HG FG
SE
E
SC
H
ED
U
LE
6" 6"
SEE SCHEDULE SEE SCHEDULE
6" 6"
SE
E
SC
H
ED
U
LE
6"6" 2'
6"
HM-1
SE
E
SC
H
ED
U
LE
SEE SCHEDULE
2"
2" 2"
V.I.F.
6' - 0"
2' - 7"
2'
PROVIDE BULLET RESISTANT
FILM ON ALL EXISTING GLASS,
EQUAL TO:
3M SCOTCHSHIELD ULTRA S800
4'
0"
3' - 0"
ALUM. FRAME
FIXED WINDOW
VE
R
IF
Y
IN
F
IE
LD
7'
1/
2"
/8
(3) 10", 14 GAUGE
CSW STEEL JOIST
(BEAR ON (1) 6" METAL
STUD EA. END, WRAP
STUD W/ALUM. TO MATCH
STOREFRONT)
SECURE TO EXISTING
ROOF STRUCTURE
5/8" GYP. EACH SIDE
ADJUST ACT CEILING
AS NECESSARY
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T N
O:
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R:
DA
TE
KEYPLAN
HIGH SCHOOL
ELEMENTARY
Z:
\B
-0
B rim le y
Ar ea
S ch oo ls
-P ha se I
R en ov at io ns
\D w gs \B
-0
.rv t
/2
2/
:2 3:
P
M
A102
ELEMENTARY
ENTRANCE FLOOR
PLAN &
SCHEDULES
SE
C
U R
E
EN
TR
AN
C E
R
EN
O
VA
TI
O
N S
BR
IM
LE
Y
AR
EA
S
CH
OO
LS
En ter ad dr es s h er e
B7 0-
D C
KC JGD
C
SE
CU
RE
E
NT
RA
NC
E
RE
NO
VA
TI
O
NS
B R
IM
LE
Y
AR
EA
S
C H
O O
LS
1/4" = 1'-0"D1 ELEMENTARY ENTRANCE DEMO PLAN
1/4" = 1'-0"D4 PROPOSED ELEMENTARY ENTRANCE PLAN
1/4" = 1'-0"A1 ELEMENTARY ENTRANCE ELEVATION
DOOR & FRAME SCHEDULE
DOOR
NO.
DOOR FRAME
HDWR SET RemarksTYPE MATERIAL
SIZE
ELEV MATERIALPAIR WIDTH HEIGHT
514 FG ALUM. 3' - 0" 7' - 0" 1 ALUM. H2
514.1 FG ALUM. 3' - 0" 7' - 0" 1 ALUM. H2
514.2 FG ALUM. 3' - 0" 7' - 0" 1 ALUM. H2
514.3 FG ALUM. 3' - 0" 7' - 0" 1 ALUM. H2
515 HG METAL 3' - 0" 7' - 0" EXISTING HM H1 ADD ALTERNATE #1
515.1 HG METAL 3' - 0" 7' - 0" EXISTING HM H1 ADD ALTERNATE #1
515.2 HG METAL 3' - 0" 7' - 0" EXISTING HM H1 ADD ALTERNATE #1
515.3 HG METAL 3' - 0" 7' - 0" EXISTING HM H1 ADD ALTERNATE #1
517 FG ALUM. 3' - 0" 7' - 0" 1 ALUM. H2
517.1 FG ALUM. 3' - 0" 7' - 0" 1 ALUM. H2
600 HG METAL X 6' - 0" 7' - 0" EXISTING HM H1 ADD ALTERNATE #2
601.1 FG ALUM. X 6' - 0" 7' - 0" 1 ALUM. H2
602 FG ALUM. 3' - 0" 7' - 0" 1 ALUM. H2
615 HG WD 3' - 0" 7' - 0" 1 HM H2 L6xL4x3/8" LINTEL (EXTEND 12" BEYOND R.O.)
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
DOOR FRAME TYPES
1/4" = 1'-0"A3 VESTIBULE 601 ELEVATION
1/4" = 1'-0"
WINDOW TYPES
3/4" = 1'-0"C5 ELEMENTARY ENTRANCE DETAIL
O W
N
ER
R E V
IE
W
/2
/2
O
W N
ER
R
E V
IE
W
/1 8/
FAAP
FACP
ELECTRICAL ABBREVIATIONS, SYMBOLS AND NOTES
ABBREVIATIONS AND SYMBOLS LEGEND NOTES & DETAILS
ELR
CARBON MONOXIDE DETECTOR
1. IT SHALL BE THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO NOTIFY OTHER
CONTRACTORS TO ARRANGE CLEARANCES AND ACCESS OPENINGS FOR ALL LARGE ELECTRICAL
EQUIPMENT.
2. IT SHALL BE UNDERSTOOD THAT THE ACT OF SUBMITTING A BID BY THE CONTRACTOR
CARRIES WITH IT THE AGREEMENT TO ALL ITEMS AND CONDITIONS REFERRED OR INDICATED OR
IMPLIED ON THE DRAWINGS AND THE SPECIFICATIONS AND NO CONSIDERATION WILL BE
GRANTED FOR ANY ALLEGED MISUNDERSTANDING OF MATERIALS TO BE FURNISHED FOR WORK
TO BE DONE.
3. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH RULES AND REGULATIONS OF THE
LATEST EDITION OF THE OCCUPATIONAL SAFETY AND HEALTH ACT, NATIONAL ELECTRICAL CODE, STATE ELECTRICAL CODE, LOCAL MUNICIPAL CODE AND ANY OTHER BOARD HAVING
JURISDICTION OVER THE ELECTRICAL INSTALLATION.
4. THE ELECTRICAL CONTRACTOR SHALL NOT ASSUME THAT ANY DRAWING OR
SPECIFICATION FORMING A PART OF THE CONTRACT DOCUMENTS AUTHORIZES THE VIOLATION
OF ANY CODE, REGULATION OR STANDARD. WHERE CONFLICTS ARISE, IT SHALL BE DEEMED THAT
THE CONTRACTOR HAS ESTIMATED THE COST OF ALL WORK TO BE COMPLETED IN ACCORD WITH
THE PREVAILING CODE.
5. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS FOR ELECTRICAL WORK AND
SHALL PAY ALL REQUIRED FEES AND SALES OR USE TAX AND FINES AS APPLICABLE TO THIS
BRANCH OF WORK.
6. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL DELIVER TO THE OWNER
WITHOUT COST ALL REQUIRED CERTIFICATES OF INSPECTION AND APPROVAL.
7. THE INTENT AND OBJECT OF THESE SPECIFICATIONS AND DRAWINGS IS TO INCLUDE A
COMPLETE WIRING SYSTEM FROM SERVICE PANEL TO EACH AND EVERY OUTLET INDICATED OR
SPECIFIED, INCLUDING CONNECTING ALL ELECTRICAL DEVICES AND/OR EQUIPMENT FURNISHED
BY THE OWNER OR OTHER CONTRACTORS.
8. THE DRAWINGS, WHICH CONSTITUTE A PART OF THE CONTRACT, ARE DIAGRAMMATIC AND
INDICATE THE GENERAL ARRANGEMENT OF CIRCUITS AND OUTLETS, LOCATION OF SWITCHES,
PANELBOARD AND OTHER WORK, BUT EXTREME ACCURACY IS NOT GUARANTEED AND FIELD
VERIFICATION OF ALL LOCATIONS AND DIMENSIONS IS DIRECTED.
9. GROUND ALL EQUIPMENT INCLUDING CONDUIT, RECEPTACLES, LIGHTING, MOTORS, PIPING
AS PER ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE, AND AS SHOWN ON THESE DRAWINGS.
10. PROVIDE ONLY MATERIALS THAT ARE NEW OF THE TYPE AND QUALITY SPECIFIED, WHERE
UNDERWRITERS LABORATORIES HAVE ESTABLISHED STANDARDS FOR SUCH MATERIALS,
PROVIDE ONLY MATERIALS BEARING THE U.L. LABEL.
11. ARCHITECTURAL DRAWINGS SHOWING DIMENSIONS FOR ELECTRICAL DEVICES TAKE
PRECEDENCE OVER THE ELECTRICAL DRAWINGS.
12. SYSTEMS SHALL BE FREE FROM SHORTS AND GROUNDS. TEST FOR MECHANICAL AND
ELECTRICAL DEFECTS. VERIFY CORRECT CONNECTION OF HOT, NEUTRAL AND GROUND
CONDUCTORS. ALL CONDUCTORS SHALL BE COLOR CODED AND LABELED WITH ZONE
IDENTIFICATION FOR THE CASE OF LIGHTING.
13. WHEN MATERIAL AND/OR WORKMANSHIP IS FOUND NOT TO COMPLY WITH THE SPECIFIED
REQUIREMENTS, WITHIN THREE DAYS AFTER RECEIPT OF NOTICE OF SUCH NON-COMPLIANCE,
REMOVE THE NON-COMPLYING ITEMS FROM THE JOB AND REPLACE WITH NEW ITEMS MEETING
THE REQUIREMENTS. COSTS FOR REPAIR OF NON-COMPLIANCE WORK SHALL BE BY THE
CONTRACTOR WITH NO ADDITIONAL COST TO THE OWNER.
14. UPON COMPLETION OF THE WORK, THOROUGHLY CLEAN ALL DEVICES AND EQUIPMENT.
15. ALL TELECOM, TV CABLE AND DATA CABLE SHALL BE DEDICATED RUNS FROM THE OUTLET
LOCATIONS TO THE BACKBOARD LOCATION.
16. WORK ASSIGNMENTS INFERRED BY THE DRAWINGS AND NOTES INCLUDED IN THESE
PROJECT DOCUMENTS ARE INFORMATIONAL ONLY AND ARE NOT INTENDED TO RELIEVE THE
BIDDING CONTRACTOR OF HIS OBLIGATION TO THE OWNER TO PROVIDE A COMPLETE AND
COORDINATED PROJECT. COMPREHENSIVE SUBCONTRACTOR COORDINATION AND FINAL WORK
ASSIGNMENTS TO SUBCONTRACTORS ARE THE SOLE RESPONSIBILITY OF THE BIDDING
CONTRACTOR.
LUMINARE - SURFACE MOUNT FLUORESCENT OR INCANDESCENT
LUMINARE - RECESSED FLUORESCENT OR INCANDESCENT
LUMINARE - STANDARD FLUORESCENT STRIP LIGHT
LIGHT FIXTURE - RECESSED FLUORESCENT OR LED
HEAT DETECTOR
DUAL LEVEL SWITCHING - SWITCH OUTER (2) LAMPS SEPARATE
FROM CENTER LAMP
FIRE ALARM HORN/STROBE (CEILING MOUNTED)
FIRE ALARM BOOSTER PANEL
FIRE ALARM SPEAKER
END OF LINE RESISTOR
FIRE ALARM HORN/STROBE (WALL MOUNTED)
MAGNETIC DOOR HOLD OPEN
GONG
DUCT SMOKE DETECTOR
TAMPER SWITCH
FLOW SWITCH
FIRE ALARM HORN/STROBE (WALL MOUNTED)
MANUAL PULL STATION
SMOKE DETECTOR
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE SAFETY AND ALARM SYMBOLS
GENERAL NOTES:
PHOTO CELL
OCCUPANCY SENSOR (WALL MOUNTED)
PANEL - RECESSED
PANEL - SURFACE MOUNT
AUTOMATIC TRANSFER SWITCH (ATS)
DISCONNECT
NORMALLY OPEN SWITCH
NORMALLY CLOSED SWITCH
CIRCUIT BREAKER WITH SIZE AS NOTED
NORMALLY OPEN CONTACT
NORMALLY CLOSED CONTACT
FUSED SWITCH
ELECTRIC METER
GROUND
IN-LINE FUSE
TRANSFORMER
STARTER DISCONNECT
THERMOSTAT
CONNECTION TO MOTOR
FUSED DISCONNECT
DISCONNECT
TELEPHONE/DATA OUTLET. PROVIDE 1"CONDUIT WITH PULL
STRING PER LOCATION. DATA CABLES AND TERMINATIONS BY
OTHERS.
SWITCH - PILOT
SWITCH - DIMMER
TYPICAL DEVICE MOUNTING HEIGHT
NOTE:
VERIFY HEIGHTS SHOWN COMPLY WITH LOCAL BUILDING CODE.
47"
1'-6"
6"
MAX.
SYMBOL
EXIT
BOTTOM OF
FINISHED CEILING
SYMBOL
FIRE ALARM
SYMBOL
LIGHTING SWITCH
SYMBOL
120V CONVENIENCE
RECEPTACLE
SYMBOL
TELEPHONE AND
COMPUTER
TOP OF FINISHED FLOOR
47"
6'-8"SYMBOL
FIRE ALARM
MANUAL PULL
STATION
OCCUPANCY SENSOR (CEILING MOUNTED)
ABBREVIATIONS
LIGHTING SYMBOLS
SWITCH - PUSH BUTTON
SWITCH - TIME CLOCK
SWITCH - SINGLE POLE, TIMED
SWITCH - SINGLE POLE, KEYED
SWITCH - FOUR WAY
SWITCH - THREE WAY
SWITCH - SINGLE POLE
A AMPERES
AV PANELBOARD AV
AV AUDIO/VIDEO
A/V AUDIO/VIDEO
C PANELBOARD KPP-C
C.B. CIRCUIT BREAKER
GFCI GROUND FAULT CIRCUIT INTERUPTING
GFI GROUND FAULT CIRCUIT INTERUPTING
KVA KILO-VOLT AMPS (ELECTRIC POWER)
QT QUAD TUBE (FLUORESCENT LAMP)
TT TWIN TUBE (FLUORESCENT LAMP)
TYP TYPICAL
V VOLT
4W FOUR WIRE
3ø THREE PHASE
JUNCTION BOX
JUNCTION BOX
TELEVISION CABLE OUTLET
CLOCK - WALL MOUNTED
AMPLIFIER
INTERCOM
SPEAKER - CEILING MOUNTED
SPEAKER - WALL MOUNTED
WIRELESS ACCESS POINT (WAP)
TELEPHONE/DATA OUTLET - FLOOR MOUNTED
POLE RECEPTACLE
ISOLATED GROUND RECEPTACLE
TOP SWITCHED RECEPTACLE
GROUND FAULT INTERUPTING RECEPTACLE. PROVIDE WEATHER-
PROOF WHILE IN USE COVER WHERE LOCATED OUTDOORS.
QUAD RECEPTACLE (GFI PROTECTED WHERE REQUIRED)
FLOOR RECEPTACLE (GFI PROTECTED WHERE REQUIRED)
DUPLEX RECEPTACLE
MISCELLANEOUS SYMBOLSSWITCHES AND RECEPTACLE SYMBOLS
TELEPHONE, DATA AND COMMUNICATION SYMBOLS
CO
F
S
F
F
FS
S D
S
TS
F
H
J
J
D
S
SS
SP
S
ST
S3
S4
SK
S
IG
G
PC
L
N E
M
T
M
C
A
IC
S
S
TV
A
LIGHT FIXTURE - EMERGENCY (WALL MOUNT)
LIGHT FIXTURE - EXIT/EMERGENCY (DIRECTIONAL ARROWS
WHERE INDICATED ON PLANS) (WALL OR CEILING MOUNT)
OSS
COUNTERTOP RECEPTACLE (GFCI WHERE REQUIRED)CTR
LIGHT FIXTURE - SURFACE FLUORESCENT OR LED
C
B
TC
F
F
SECURITY CAMERA (OUTDOOR/INDOOR PER PLAN)
DOOR ALARM KEYPAD. PROVIDE 1"CONDUIT WITH PULL STRING PER
LOCATION. DATA CABLES AND TERMINATIONS BY OTHERS.
DL
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T N
O:
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R:
DA
TE
P:
\B
-0
B rim le y
Ar ea
S ch oo ls
-P ha se I
R en ov at io ns
\D w gs \E le ct ric al
\B
-0
_B rim le y Ar ea S ch oo ls
Ph as e
R en ov tio ns _E le ct ric al
.rv t
/2
2/
1:
:4
AM
E001
ELECTRICAL
ABBREVIATIONS
SE
C
U R
E
EN
TR
AN
C E
R
EN
O
VA
TI
O
N S
BR
IM
LE
Y
AR
EA
S
CH
OO
LS
BR
IM
LE
Y, M I
B7 0-
SP PM JGPM
SE
CU
RE
E
NT
RA
NC
E
RE
NO
VA
TI
O
NS
B R
IM
LE
Y
AR
EA
S
C H
O O
LS
/1 8/
R
EV
IE
W
G
G
1 ADDITIVE ALTERNATIVE #1: DISCONNECT EXISTING ELECTRIC STRIKE AND RECONNECT FOR DOOR REPLACEMENT.
KEYNOTES
2 REMOVE EXISTING PENDANT LIGHTS. REPLACE WITH NEW PENDANT FIXTURES AS SHOWN. CONNECT TO EXISTING
WIRING.
3 NEW EXIT/EMERGENCY COMBO. CONNECT TO UNSWITCHED HOT OF IDENTIFIED CIRCUIT.
4 NEW CONTROLLER. PROVIDE LOW VOLTAGE CONNECTION PER MANUFACTERER'S SPECIFICATIONS BACK TO MAIN
CONTROL PANEL.
5 ELECTRIC STRIKE. PROVIDE HOME RUN TO NEW CONTROLLER.
6 CARD READER. PROVIDE HOME RUN TO NEW CONTROLLER.
7 CAMERA/DOORBELL STATION. PROVIDE HOME RUN TO NEW CONTROLLER.
8 "LOCKDOWN" BUTTON. PROVIDE HOME RUN TO NEW CONTROLLER.
9 ACCESS CONTROL Ai PHONE MASTER STATION WITH WIRING TO CONTROL PANEL. PROVIDE HOME RUN TO NEW
CONTROLLER.
10 SHIFT EXISTING 2x4 TROFFER (2) FEET TO MISS INSTALLATION OF NEW DOORS.
11 PROVIDE NEW GFCI FOR RELOCATED WATER COOLER. EXTEND EXISTING CIRCUIT AS REQUIRED.
12 NEW EMERGENCY LIGHT. CONNECT TO UNSWITCHED HOT OF IDENTIFIED CIRCUIT.
13 REMOVE AND REPLACE EXISTING EXIT LIGHT WITH NEW EXIT/EMERGENCY. CONNECT TO EXISTING WIRING.
14 REMOVE EXISTING SWITCH AND ASSOCIATED CONDUIT AND WIRING AND RELOCATE TO LOCATION SHOWN.
EXTEND POWER AND SWITCH LEG TO NEW LOCATION. USE METALLIC WIREMOLD IF NOT FEASIBLE TO FISH IN
EXISTING WALLS. PROVIDE BLANK AT REMOVED SWITCH LOCATION.
15 REMOVE EXISTING RECEPTACLE AND ASSOCIATED CONDUIT AND WIRING. EXTEND WIRING TO KEEP ADJACENT DEVICES ACTIVE. USE METALLIC WIREMOLD FOR CIRCUIT EXTENSION IF NOT FEASIBLE TO FISH IN EXISTING
WALLS.
16 PROVIDE POWER SUPPLY AND RELAY ENCLOSURE FOR DOOR STRIKE POWER SUPPLY. (LOCATE ABOVE
ACCESSIBLE CEILING). PROVIDE 120V CONNECTION AS INDICATED.
RECEPTION
CLASSROOM
LOBBY
VEST.
WAITING
EX. PANEL
RLP-A1A
DEDICATED 120V FROM EX. PANEL
RLP-A1A. PROVIDE NEW BREAKER
AS REQUIRED
5 6
WORK
OFFICE
CAFETERIA
A
A
XA
B
B
XA
EA
RECEPTION
CORRIDOR
VESTIBULE
OFFICE
EX. ELECTRIC STRIKE
TO REMAIN
EX. PANEL EO
DEDICATED 120V FROM EX. PANEL EO.
PROVIDE NEW BREAKER
AS REQUIRED
XA XA
EA
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T N
O:
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R:
DA
TE
KEYPLAN
HIGH SCHOOL
ELEMENTARY
P:
\B
-0
B rim le y
Ar ea
S ch oo ls
-P ha se I
R en ov at io ns
\D w gs \E le ct ric al
\B
-0
_B rim le y Ar ea S ch oo ls
Ph as e
R en ov tio ns _E le ct ric al
.rv t
/2
2/
1:
:4
AM
E101
ELECTRICAL PLAN
SE
C
U R
E
EN
TR
AN
C E
R
EN
O
VA
TI
O
N S
BR
IM
LE
Y
AR
EA
S
CH
OO
LS
BR
IM
LE
Y, M I
B7 0-
SP PM JGPM
SE
CU
RE
E
NT
RA
NC
E
RE
NO
VA
TI
O
NS
B R
IM
LE
Y
AR
EA
S
C H
O O
LS
1/4" = 1'-0"A1 SOUTH HIGH SCHOOL ENTRANCE
1/4" = 1'-0"A4 ELEMENTARY ENTRANCE
/1
8/
R
EV
IE
W
PLASTIC BUSHING AND
CONDUIT ELBOW ABOVE
CEILING. (TYP)
WALL
DOOR FRAME
ELECTRIC STRIKE
FLUSH MOUNT CARD
READER OR CAMERA STATION
HOME RUN TO CONTROLLER (TYP)
TYPE
LIGHT FIXTURE SCHEDULE
DESCRIPTION MANUFACTURER CATALOG NUMBER LAMP/LUMEN WATTS NOTES
Notes:
1. CONNECT TO UNSWITCHED HOT OF IDENTIFIED CIRCUIT.
2. PROVIDE DIRECTIONAL ARROWS AS REQUIRED.
3. HANG LIGHTS TO SAME HEIGHT OF EXISTING LIGHTS.
A 12' LINEAR LED PRUDENTIAL LTG. WV2-LED4-LO-MO-R12-WA-TMW-D3-CW-SC-UNV-CA48"-X3-DM01 LED/1360 DN,2080 UP 32.8
EA EMERGENCY LIGHT AP2SQLED LED 2.2 1,2COOPER-SURE LITE
MOUNTING
SUSPENDED
8' AFF
B 20' LINEAR LED PRUDENTIAL LTG. WV2-LED4-LO-MO-R20-WA-TMW-D3-CW-SC-UNV-CA48"-X3-DM01 LED/2720 DN,4160 UP 65.6 SUSPENDED 3
XA EXIT/EMERGENCY LIGHT APCH7RSQ LED 2.2 1,2COOPER-SURE LITE WALL/CEILING
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T N
O:
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R:
DA
TE
P:
\B
-0
B rim le y
Ar ea
S ch oo ls
-P ha se I
R en ov at io ns
\D w gs \E le ct ric al
\B
-0
_B rim le y Ar ea S ch oo ls
Ph as e
R en ov tio ns _E le ct ric al
.rv t
/2
2/
1:
:4
AM
E501
ELECTRICAL
DETAILS
SE
C
U R
E
EN
TR
AN
C E
R
EN
O
VA
TI
O
N S
BR
IM
LE
Y
AR
EA
S
CH
OO
LS
BR
IM
LE
Y, M I
B7 0-
SP PM JGPM
SE
CU
RE
E
NT
RA
NC
E
RE
NO
VA
TI
O
NS
B R
IM
LE
Y
AR
EA
S
C H
O O
LS
/1 8/
R
EV
IE
W
NOT TO SCALEA4 CONTROLLER DIAGRAM
NOT TO SCALEA2 TYPICAL CONTROLLER INSTALLATION
NOT TO SCALEC4 CARD READER/DOOR STRIKE DETAIL
| G001 |
| Sheets |
| G001 - COVER SHEET |
| A101 |
| Sheets |
| A101 - HIGH SCHOOL ENTRANCE FLOOR PLAN |
| A102 |
| Sheets |
| A102 - ELEMENTARY ENTRANCE FLOOR PLAN & SCHEDULES |
| B70-00273_Brimley Area Schools - Phase 1 Renovations_Electrical (1) |
| Sheets |
| E001 - ELECTRICAL ABBREVIATIONS |
| E101 - ELECTRICAL PLAN |
| E501 - ELECTRICAL DETAILS |
File details come from the government source that posted it. Updated .