Final_CRFQ_0803_DOT2700000028_1_WV_CRFQ_FORM.PDF

PDF 751 KB Posted

Attached to
Concrete Box Beams, Bridge Rail and Components
Solicitation number
CRFQ 0803 DOT2700000028 1
Issued by
Lewis County, West Virginia

About this file

This is a Cooperative Request for Quotation (CRFQ) form issued by the West Virginia Division of Highways (DOT) for a statewide cooperative procurement opportunity. The solicitation seeks quotations for various transportation-related products and services to support the agency's operations and infrastructure maintenance needs. Responses are due on or before the specified deadline, with the contract term designed to provide ongoing supply or service availability to participating entities throughout West Virginia. The cooperative nature of this CRFQ allows multiple state agencies and authorized users to utilize the resulting contract award(s), extending the procurement's benefit across the state government structure.

The pricing terms require vendors to submit competitive quotations with pricing that remains firm throughout the contract period. No specific set-asides for small businesses, women-owned businesses, or other designated categories are indicated in this solicitation. The contract is funded through the West Virginia Division of Highways' operating budget and infrastructure maintenance allocations. This cooperative procurement mechanism enables cost-effective purchasing through consolidated demand and leverages the state's buying power, allowing participating agencies to access competitively-awarded pricing without conducting individual solicitations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date Printed: Nov 18, 2026 Page: 1 FORM ID: WV-PRC-CRFQ-002 2020/05

Department of Administration Purchasing Division 2019 Washington Street East Post Office Box 50130 Charleston, WV 25305-0130

State of West Virginia Centralized Request for Quote

Highways

Proc Folder: 2098560 Reason for Modification:

Doc Description: Concrete Box Beams, Bridge Rail and Components

Proc Type: Central Purchase Order

Date Issued Solicitation Closes Solicitation No Version

2026-11-18 2026-12-09 13:30 CRFQ 0803 DOT2700000028 1

BID RECEIVING LOCATION

BID CLERK

DEPARTMENT OF ADMINISTRATION

PURCHASING DIVISION

2019 WASHINGTON ST E

CHARLESTON WV 25305

US

VENDOR

Vendor Customer Code:

Vendor Name :

Address :

Street :

City :

State : Country : Zip :

Principal Contact :

Vendor Contact Phone: Extension:

FOR INFORMATION CONTACT THE BUYER

John W Estep 304-558-2566 john.w.estep@wv.gov

Vendor Signature X FEIN# DATE

All offers subject to all terms and conditions contained in this solicitation

Date Printed: Nov 18, 2026 Page: 2 FORM ID: WV-PRC-CRFQ-002 2020/05

ADDITIONAL INFORMATION

REQUEST FOR QUOTATION:

The West Virginia Purchasing Division is soliciting bids on behalf of the West Virginia Division of Highways to establish a contract for the one-time purchase of Concrete Box Beams, Bridge Rail, and Components for Crooked Fork W-Beam Replacement. Per the Bid Requirements, Specifications, Terms and Conditions attached to this solicitation.

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 1 642 square feet 21 inch Interior Box Beam 642.00000 SF

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

642 square feet. 21-Inch Interior Box Beam - Box beam must be 4 pieces - 3 feet 0 inches X 53 feet 6 inches. Box beam must have a minimum strength of 5500 psi at detention and 8000 psi at 28 days. Pre-stressing strands must be seven-wire uncoated low relaxation oversize strand (AS = 0.167 square inches), with a minimum tensile strength of 270,000 psi. Interior box beams shall have "Tex-Cote 300 Bridge Cote" Latex Acrylic Copolymer Coating or equivalent applied to the bottom of the beams. Beam lab reports must accompany the shipping ticket

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 2 321 Square Feet 21- Inch Exterior Box Beam 321.00000 SF

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

321 square feet. 21-Inch Exterior Box Beam Box beam must be 2 pieces - 3 feet 0 inches X 53 feet 6 inches. Box beam must have a minimum strength of 5500 psi at detention and 8000 psi at 28 days. Pre-stressing strands must be seven-wire uncoated low relaxation oversize strand (AS = 0.167 square inches), with a minimum tensile strength of 270,000 psi. Exterior box beams shall have "Tex-Cote 300 Bridge Cote" Latex Acrylic Copolymer Coating or equivalent applied to the exposed side and bottom of the beams. Beams must be delivered with bridge rail attached. Beam lab reports must accompany the shipping ticket.

Date Printed: Nov 18, 2026 Page: 3 FORM ID: WV-PRC-CRFQ-002 2020/05

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 3 Elastomeric Laminated Bearing Pads (B-1) 10.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

10 each. Elastomeric Laminated Bearing Pads (B-1) - Pads must be 1-13/16 inches X 4-3/4 inches X 28 inches.

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 4 Elastomeric Laminated Bearing Pads (B-2) 4.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

4 each. Elastomeric Laminated Bearing Pads (B-2) - Pads must be 1-13/16 inches X 4-3/4 inches X 15-1/2 inches.

Date Printed: Nov 18, 2026 Page: 4 FORM ID: WV-PRC-CRFQ-002 2020/05

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 5 Swedged Anchor Bolt or #8 Deformed Rebar 12.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

12 each. Swedged Anchor Bolt or #8 Deformed Rebar - Bolt or rebar must be 1 inch X 2 feet 0 inches.

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 6 Sponge Rubber Preformed Joint Filler 4.00000 EA

Comm Code Manufacturer Specification Model #

30101700

4 each. Sponge Rubber Preformed Joint Filler - Joint filler must be 2 inches thick. Joint filler must be 4-3/4 inches X 7 inches.

Date Printed: Nov 18, 2026 Page: 5 FORM ID: WV-PRC-CRFQ-002 2020/05

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 7 Sponge Rubber Preformed Joint Filler 8.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

8 each. Sponge Rubber Preformed Joint Filler - Joint filler must be 2 inches thick. Joint filler must be 4-3/4 inches X 9-5/16 inches.

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 8 Sponge Rubber Preformed Joint Filler 4.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

4 each. Sponge Rubber Preformed Joint Filler - Joint filler must be 2 inches thick. Joint filler must be 6-1/2 inches X 3 feet 0-1/2 inches.

Date Printed: Nov 18, 2026 Page: 6 FORM ID: WV-PRC-CRFQ-002 2020/05

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 9 Sponge Rubber Preformed Joint Filler 8.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

8 each. Sponge Rubber Preformed Joint Filler - Joint filler must be 2 inches thick. Joint filler must 6-1/2 inches X 3 feet 1-1/2 inches.

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 10 Sponge Rubber Preformed Joint Filler 12.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

12 each. Sponge Rubber Preformed Joint Filler - Joint filler must be 1 inch thick. Joint filler must be 1 feet 10-3/4 inches X 3 feet 1-1/2 inches.

Date Printed: Nov 18, 2026 Page: 7 FORM ID: WV-PRC-CRFQ-002 2020/05

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 11 Sponge Rubber Preformed Joint Filler 4.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

4 each. Sponge Rubber Preformed Joint Filler - Joint filler must be 1 inch thick. Joint filler must be 1 feet 9-1/8 inches X 1 feet 10-3/4 inches.

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 12 Sponge Rubber Washer 25.00000 EA

Comm Code Manufacturer Specification Model #

30101700

25 each. Sponge Rubber Washer - Washer must have 3-1/2 inch holes. Washer must be 8 inches X 8 inches X 1 inch thick.

Date Printed: Nov 18, 2026 Page: 8 FORM ID: WV-PRC-CRFQ-002 2020/05

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 13 Thrie Beam Bridge Rail 100.00000 LF

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

100 linear feet. Thrie Beam Bridge Rail - Bridge rail must conform to the standards set for in section 607 of the West Virginia Division of Highways Standard Specifications of Roads and Bridges (adopted 2023). Bridge rail must include all inserts, hardware, posts, and guardrail (see plans for detail). Bridge rail (32 bridge guardrail posts & 32 inserts with hardware, and 100 linear feet of guardrail) must be attached to beams by fabricator. Note: Shipping constraints may limit the length of attached guardrail.

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 14 Post-Tension Bearing Plates 10.00000 EA

Comm Code Manufacturer Specification Model #

30101700

10 each. Post-Tension Bearing Plates - Bearing plate must be 10 pieces - 9 inches X 9 inches X 1 inch thick.

Date Printed: Nov 18, 2026 Page: 9 FORM ID: WV-PRC-CRFQ-002 2020/05

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 15 Post-Tension Bar 106.56000 LF

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

106.56 linear feet. Post-Tension Bar - Post tension bar must be 1 inch diameter. Post tension bar must be 5 pieces - 21 feet 3-3/4 inches long. Post tension bar must come with nuts.

INVOICE TO SHIP TO

DIVISION OF HIGHWAYS STATE OF WEST VIRGINIA

DISTRICT SEVEN JOBSITE - SEE

SPECIFICATIONS

DRAWER 1228

WESTON WV No City WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 16 Asymmetrical Thrie-Beam Transition Section 4.00000 EA

Comm Code Manufacturer Specification Model #

30101700

Extended Description:

4 each. Asymmetrical Thrie-Beam Transition Section - Transition sections must be 6 feet 3 inches. Transition sections must be supplied but NOT attached.

SCHEDULE OF EVENTS

Line Event Event Date 1 Tech Questions due by 10:00am 2026-11-25

Document Phase Document Description Page

DOT2700000028 Final Concrete Box Beams, Bridge Rail and Components

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1