FINAL ADDENDUM NO 2 FS1219 26.pdf
PDF 178 KB Posted
- Solicitation number
- B26002508
- Issued by
- Maui County, Hawaii
About this file
This is Addendum No. 2 to a solicitation issued by the State of Hawaii Department of Transportation Airports Division for the furnishing and delivery of two multi-purpose structural fire fighting vehicles. The first vehicle is designated for Kahului Airport on Maui, and the second for Daniel K. Inouye International Airport on Oahu. The addendum, issued on May 15, 2026, provides responses to eight requests for information submitted by vendors regarding technical specifications. The original proposal submission deadline was May 15, 2026, for solicitation B26002508 FS1219-26. Delivery of both vehicles must occur within 1,095 calendar days from the Notice to Proceed. The specifications for these procurements are restrictive with no substitutions or equal products permitted; bidders must specify the exact Pierce model being offered and demonstrate full compliance with all technical requirements outlined in the solicitation documents.
The addendum demonstrates that the State of Hawaii rejected all vendor requests for specification modifications or deadline extensions. Specifically, vendors requested changes to wheelbase specifications (from 195.00 to 220.00 inches), gross vehicle weight rating (from 46,500 to 53,800 pounds), hose tray capacity adjustments, hose bed configurations, rear compartmentation dimensions, and removal of the pike pole requirement. All eight requests were denied with the directive to "bid accordingly." The State also declined a vendor request for a two-week extension of the question and offer due dates, requiring vendors to proceed with their bids based on the original specifications. Award will be made to the lowest responsive and responsible bidder within sixty calendar days of bid opening based on total price comparison, with pricing serving as the sole evaluation criterion.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FINAL ADDENDUM NO 1 FS1219 26.pdf | ||
| FINAL SPECIFICATIONS w NTB FS1219 26.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ONE (1) MULTI-PURPOSE STRUCTURAL ADDENDUM NO. 2
FIRE FIGHTING VEHICLE AT KAHULUI AIRPORT May 15, 2026
AND ONE (1) MULTI-PURPOSE STRUCTURAL PAGE 1 OF 1
FIRE FIGHTING VEHICLE AT
DANIEL K. INOUYE INTERNATIONAL AIRPORT
PROJECT NO. FS1219-26
STATE OF HAWAII
DEPARTMENT OF TRANSPORTATION
AIRPORTS
ADDENDUM NO. 2
FOR
FURNISHING AND DELIVERY OF
ONE (1) MULTI-PURPOSE STRUCTURAL FIRE FIGHTING VEHICLE
AT KAHULUI AIRPORT,
KAHULUI, MAUI, HAWAII
AND
ONE (1) MULTI-PURPOSE STRUCTURAL
FIRE FIGHTING VEHICLE AT
DANIEL K. INOUYE INTERNATIONAL AIRPORT,
HONOLULU, OAHU, HAWAII
PROJECT NO. FS1219-26
May 15, 2026
The following is provided for information.
A. RESPONSES TO REQUESTS FOR INFORMATION (RFI’S/QUESTIONS)
1. The attached RESPONSES TO REQUEST FOR INFORMATION are provided for information.
Please acknowledge receipt of this ADDENDUM NO. 2 by recording the date of its receipt in the space provided on PAGE PF-4 of the Proposal.
CURT T. OTAGURO
Deputy Director of Transportation for Airports
Questions for solicitation: B26002508 FS1219-26 Furnishing & Delivery of
Multi-Purpose Structural Fire Fighting
05/15/2026
1. Vendor would like to request a 2 week extension, please advise as soon as possible.
Please refer to Addendum No. 1, released on May 12, 2026.
2. Would the State of Hawaii be willing to extend the deadline for questions and the offer due date by two weeks? A two-week extension would allow vendors adequate time to evaluate specifications, submit questions if needed, review any responses or addenda issued, and submit their most responsive bid.
No, please bid accordingly.
3. Section 10 General Specification Page 11-4, Wheelbase The wheelbase for the vehicle shall be 195.00 Question; Clarification the updated wheelbase with the longer body will be
220.00 is this acceptable?
Not acceptable, please bid accordingly.
4. Section 10 General Specification Page 11-4 GVW Rating The gross vehicle weight rating shall be 46,500. Question; Clarification the updated GVW Rating shall be 53,800, ius this acceptable?
5. Section 10 General Specification Page 11-18 Hose Tray Right Side A hose tray shall be placed in the right side of the extended bumper. The tray shall have a capacity of 25’ of 5’ double jacket cotton-polyester hose. Question; Clarification is 20’ of 5” acceptable due to the size of the compartment?
6. Section 10 General Specification Page 11-71 Hose Bed Hose bed shall accommodate #1 reverse lay 500’, 3” x 2.5” #2 LDH Hose 4”, 800’-1000’ #3 forward Lay 750’ 3’ x 2.5” #4
Forward lay 400? 1.75” Question; Based on the current configuration, we have calculated the following hose capacity will fit in the hose bed: 1) 500' of 3.00" DJP Hose 2) 950' of
4.00" DJP Hose 3) 750' of 3.00" DJP Hose 4) 350' of 1.75" DJP Hose
7. Section 10 General Specification Page 11-79 Rear Compartmentation A roll-up door compartment above the rear tailboard shall be provided. The interior dimensions of this compartment shall be 43.50” high. Question; Clarification, due to the upper ladder compartment will a 35.50” high compartment be acceptable.
8. Section 10 General Specification Page 11-89 Pike pole provided by fire department One
8’ pike pole, Fire Hooks Unlimited, Model RH8, 8’ long roof hook, with pry end and steel handle shall be provided and located in the right-side long tool storage. Question, Clarification, the 8’ pike pole is not required, this will be removed from the file is this acceptable?