Fence Specifications.docx.pdf
PDF 73 KB Posted
- Attached to
- PKAA, DRUM West Calamity Outlaw Project
- Solicitation number
- DQ1 PKAA 2027000029 1
- Issued by
- Colorado
About this file
This Fence Specifications document for the Colorado PKAA, DRUM West Calamity Outlaw Project provides detailed technical requirements for the construction and installation of a welded steel fence system to close an adit (mine entrance) with a dangerous overhang. The project requires approximately 17 linear feet of steel fencing, 10 feet high, constructed and installed according to specified standards. The contractor shall provide all labor, materials, and necessary appurtenances for the installation. Materials must be new, sound, and free of decay and rust, conforming to ASTM A36 and ASTM A500/A513 structural steel standards. The fence system shall utilize 0.5" by 0.5" by 4' pickets spaced 6" center-to-center, 2" by 2" by 1/4" angle iron rails, and 3" by 3" by 3/16" steel tubing posts. The fence must be positioned at a minimum of 6 feet from all edges of the adit to ensure safety.
The fence construction requires posts spaced 6 feet on center with all seams and intersections to be welded, including a 45-degree angled crown welded to the top of each post to prevent water collection. Posts shall be encased in concrete footings 3 feet deep and 1 foot in diameter with a minimum compressive strength of 3,500 psi at 28 days, with exceptions permitted where bedrock is encountered. A maximum gap of 3 inches between ground surface and the lowest picket height must be maintained. All materials shall be inspected upon site delivery and stored to protect against damage, weather, vandalism, and theft. A minimum 24-hour cure period must pass before stress is applied to concrete-set posts, and all rail and posts shall be joined by welding 18 inches from the top and bottom of the posts with a protective cap welded to all sides of each post.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fence Specifications
5898 A2 will be closed with welded steel fence. 5898 A2 is an adit with a very dangerous overhang, The fence is to be set at a minimum of 6 feet from all edges of the adit. The closure requires approximately seventeen linear feet (17') of steel fencing, eight feet (8’') high with a crown to be constructed and installed per the following specifications:
The contractor shall provide all labor, materials and appurtenances necessary for installation of the welded steel fence system defined in this scope of work.
Upon receipt at the job site, all materials shall be checked to ensure that no damage occurred during shipping or handling. Materials shall be stored in such a manner to protect against damage, weather, vandalism and theft.
Materials
All materials shall be sound, new and free of decay and rust.
Structural Steel for fence panels and posts shall conform to the requirements of ASTM
A36, ASTM A500/A513.
Pickets shall be 0.5”x0.5”x4’. Pickets shall be spaced at 6” (center to center).
Rails shall be angle iron 2”x2”x1/4”.
Fence Post shall be 3”x3”x 3/16 steel tubing. Pickets, rails and posts shall be pre-cut to specified lengths.
Top Crown A twenty four inch (24”) post shall extend to a forty five (45°) degree angle from top of picket shall be cut and welded to the top of each post to prevent water from collecting in the post.
Concrete shall be used to encase the post where no competent rock is present.
Concrete shall have a minimum compressive strength of 3,500 psi at 28 days. Footings shall be 3’ deep and 1’ in diameter.
Fence Construction
The completed fences must be a minimum of ten feet (10') high, for the approximate length of seventeen feet (17').
The fences will be constructed utilizing the materials described above, with the posts spacing set six foot (6') on center and vertical picket spacing set six inches (6") on centers. Top and bottom rails will be placed eighteen inches (18”) below and above the top and bottom of pickets, respectively. Pickets, rails, and posts should be pre-cut to specified lengths to ensure a minimum picket top height of ten feet (10') above adjacent ground elevation. All rail and posts shall be joined by welding all seams eighteen inches (18") from the top and bottom of the posts. All picket and rail intersections shall also be joined by welding at all margins. A cap will be cut and welded on all sides to the top of each post to prevent water from collecting in the post. A maximum gap of three inches (3”) will be maintained at all times from ground surface to lowest picket height.
Fence post shall be spaced every six feet on center and be encased in concrete to a minimum depth of three feet (3') and minimum one foot (1') diameter or welded to a pre-set post base. The posts base shall be 3.5”x3.5”x1/4” plate welded to three foot (3’) long #4 rebar in a one foot (1’) diameter concrete footing. The bottom six inches (6”) of the rebar must be bent to 90 degrees. Stress shall not be applied to posts set in concrete for a period of at least 24 hours following the development of a firm set of the concrete. Exceptions on footing depth and diameter may be made where bedrock is encountered. Backfill, either earth or concrete, shall be crowned-up around post at the ground surface.