This is a pricing template spreadsheet for a Blanket Purchase Agreement (BPA) for aircraft wire and cable at Edwards Air Force Base. The template requires vendors to provide per-foot pricing across different quantity tiers (1,000 to 20,000 feet) for various types of wire and cable from approved manufacturers including Carlisle Interconnect, Furakawa, Harbour Industries, Judd Wire, Quirk Wire, TE Connectivity, Times Microwave, and Tyco Electronics.

The specifications require all wire and cables to have orange outer jackets (unless otherwise specified), be UV laser markable, and come in minimum 250-foot continuous lengths per reel. Products include twinaxial/triaxial cables, fiber optic cables, coaxial cables, hookup wires, shielded cables, and thermocouple cables meeting military specifications. Vendors must be authorized distributors of QPL or approved manufacturer items (no brokers), provide monthly lead time updates, include test reports and certifications with shipments, and notify the Air Force of all shipments via email to 812AITS.ENI.WireInventory@us.af.mil with tracking details and packing information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bidder's Info

Bidder's Name
CAGE Code
Address
Company Phone Number
Company Contact
Email Address
Contact Phone Number

Requirements

REQUIREMENTS
1. ALL WIRE AND CABLES WILL BE ORANGE OUTER JACKET, UNLESS OTHERWISE SPECIFIED.
2. ORANGE JACKET / INSUATION COLOR WILL NOT BE ACHIEVED USING AN ORANGE INK TO PAINT (STRIPE) THE JACKET.
3. ALL WIRE AND CABLES WILL BE UV LASER MARKABLE.
4. ALL WIRE AND CABLES WILL BE 250 FT MINIMUM SEGMENT LENGTHS UNLESS OTHERWISE SPECIFIED.
5. ONLY 1 CONTINUOUS LENGTH OF WIRE OR CABLE PER REEL. MULTIPLE LENGTHS OF WIRE AND CABLE ON A SPOOL OR REEL ARE NOT ALLOWED.
6. SOLID COLORS WILL BE USED IN ACCORDANCE WITH MIL-STD-681F TABLE 1, COLOR CODE: 0=BLACK; 1=BROWN; 2=RED; 3=ORANGE; 4=YELLOW; 5=GREEN; 6=BLUE; 7=VIOLET 8=GREY, 9=WHITE.
7. ALL WIRE AND CABLES WILL BE MEASURED IN FEET.
8. LEAD-TIME IN WARO = WEEKS AFTER RECEIPT OF ORDER.
9. MANUFACTURER TEST REPORTS AND MATERIAL CERTIFICATION DOCUMENTS REQUIRED WITH EACH SHIPMENT
10. DISTRIBUTOR TO INCLUDE NAME(S) OF WIRE AND CABLE MANUFACTURERS FOR EACH ITEM QUOTED WITH PROPOSAL / QUOTATION
11. BPA SUPPLIER PARTICIPANT MUST BE AN AUTHORIZED DISTRIBUTOR OF THE QPL OR APPROVED MANUFACTURER ITEMS LISTED IN THIS DOCUMENT. NO BROKERS
12. BPA SUPPLIER TO INCLUDE COLUMN PRICING (1,000 FT to 20,000 FT)
13. BPA SUPPLIER TO INDICATE MINIMUM ORDER QUANTITY (IF ANY MINIMUM ORDER QUANTITY APPLIES). ENTER "N/A" INTO PRICING CELLS BELOW MINIMUM ORDER QUANTITY IF APPLICABLE
14. BPA SUPPLIER TO PROVIDE MONTHLY UPDATES OF LEAD-TIMES (EXPRESSED IN WEEKS ARO (AFTER RECEIPT OF ORDER) FOR THE ITEMS LISTED ON BPA FOR INVENTORY PLANNING AND PURCHASING FOR THE DURATION OF THE BPA.
15. LABELS ON SPOOLS AND REELS MUST INCLUDE SELLER NAME (BPA SUPPLIER) , SHIPMENT DATE, ORDER NUMBER, WIRE OR CABLE PART NUMBER, PRODUCT DESCRIPTION, QTY ON SPOOL OR REEL, NAME OF MANUFACTURER OF PRODUCT, MANUFACTURER LOT NUMBER, AND DATE OF MANUFACTURE.
16. The Contractor shall notify the Air Force via email at 812AITS.ENI.WireInventory@us.af.mil of all shipments, including tracking information, in a timely manner. This notification shall be sent promptly upon shipment, and shall include the following information:

1) A copy of the packing slip for the shipment

2) Shipment tracking information

3) Estimated on-dock date (delivery date)

In addition to shipment notifications, the Contractor shall also provide the Air Force with regular updates of open order status for all open orders, and new order lead-times After Receipt of Order (ARO). Specifically, the Contractor shall send an email to 812AITS.ENI.WireInventory@us.af.mil on the 1st day of each month, which shall include:

1) The updated lead-time in weeks ARO for new orders for all BPA contract items using the Edwards supplied Excel spreadsheet

2) An open order status update, using the Edwards supplied spreadsheet, of all open orders, including the following information for each order:

Part number
Quantity
On-dock date (if applicable)

These updates shall be provided to facilitate effective inventory management and ensure timely tracking of order status and shipment information. The Contractor will send the open order information, on dock date information, and lead-time (ARO) for new orders via email to 812AITS.ENI.WireInventory@us.af.mil using the Excel spreadsheets provided by Edwards AFB

Carlisle Interconnect

LINETWINAXIAL/TRIAXIAL CABLECABLE JACKET COLORCarlisle InterconnectMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
33CABLE, TWINAX 26 ga, High Strength Plated Alloy, 2 Cond, Twisted pair per M17 for balanced line of 120 OHM +/- 12, Shielded 90% Min. coverage (aluminized foil tape – facing out, and Silver plated copper braid), Orange Extruded FEP Jacket. CABLE JACKET MUST BE UV LASER MARKABLE. Min. segment length of 250 FEETORANGECarlisle Interconnect33

Furakawa

LINEFiber Optic Cable. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORFurakawaLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
77C25964 FlightGuide Simplex 1.8 mm Multimode 50/125 OM3 Fiber Cptic Cable, Orange XL-ETFE Outer Jacket. Outer Cable Jacket must be UV Laser Markable.ORANGEOFS / Furakawa77

Harbour Industries

LINECOAXIAL CABLE. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORHarbour IndustriesLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
24M17/060-RG142 ORANGE XL-ETFE JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGEHarbour Industries24
25M17/128-RG400 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGEHarbour Industries25
26M17/ 94-RG179 ORANGE XL-ETFE JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGEHarbour Industries26
27M17/113-RG316 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGEHarbour Industries27
28M17/110-RG302 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGEHarbour Industries28
31LL335i Low Loss Flexible Coax Cable DC to 18 GHz at 50 Ohms Impedance. Orange jacket preferred.ORANGEHarbour Industries31
LINETWINAXIAL/TRIAXIAL CABLE. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORHarbour IndustriesLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
32CABLE, RADIO FREQUENCY, FLEXIBLE, TWIN, M17/176-00002 ORANGE XL-ETFE JACKET 77 OHM. CABLE JACKET MUST BE UV LASER MARKABLEORANGEHarbour Industries32
LINECAT CABLE. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORHarbour IndustriesLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
75CAT-6 E10024W209-3 ORANGE CABLE JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGEHarbour Industries75

Judd Wire

LINEHOOK UP WIRE (Silver-Plated Copper) NOTE 2 AWG IS A CUSTOM NON-STANDARD CONSTRUCTIONHOOKUP WIRE INSUALTION COLORJudd WireLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
1MIL-W-22759/43- 2-3 | SAE AS22759/43- 2-3 (Non-Standard Construction orange wire insulation and orange Nomex over braid) JWZRD-0812-2-3 (H23430290302) with Orange Nomex braidORANGEJudd Wire1
2MIL-W-22759/43- 6-3 | SAE AS22759/43- 6-3ORANGEJudd Wire2
3MIL-W-22759/43- 8-3 | SAE AS22759/43- 8-3ORANGEJudd Wire3
4MIL-W-22759/44-12-3 | SAE AS22759/44-12-3ORANGEJudd Wire4
5MIL-W-22759/44-12-4 | SAE AS22759/44-12-4YELLOWJudd Wire5
6MIL-W-22759/44-12-9 | SAE AS22759/44-12-9WHITEJudd Wire6
7MIL-W-22759/44-12-0 | SAE AS22759/44-12-0BLACKJudd Wire7
8MIL-W-22759/44-16-3 | SAE AS22759/44-16-3ORANGEJudd Wire8
9MIL-W-22759/44-16-4 | SAE AS22759/44-16-4YELLOWJudd Wire9
10MIL-W-22759/44-16-9 | SAE AS22759/44-16-9WHITEJudd Wire10
11MIL-W-22759/44-16-0 | SAE AS22759/44-16-0BLACKJudd Wire11
12MIL-W-22759/44-20-3 | SAE AS22759/44-20-3ORANGEJudd Wire12
13MIL-W-22759/44-20-4 | SAE AS22759/44-20-4YELLOWJudd Wire13
14MIL-W-22759/44-20-9 | SAE AS22759/44-20-9WHITEJudd Wire14
15MIL-W-22759/44-20-0 | SAE AS22759/44-20-0BLACKJudd Wire15
16MIL-W-22759/44-22-3 | SAE AS22759/44-22-3ORANGEJudd Wire16
17MIL-W-22759/44-22-4 | SAE AS22759/44-22-4YELLOWJudd Wire17
18MIL-W-22759/44-22-9 | SAE AS22759/44-22-9WHITEJudd Wire18
19MIL-W-22759/44-22-0 | SAE AS22759/44-22-0BLACKJudd Wire19
20MIL-W-22759/44-24-3 | SAE AS22759/44-24-3ORANGEJudd Wire20
21MIL-W-22759/44-24-4 | SAE AS22759/44-24-4YELLOWJudd Wire21
22MIL-W-22759/44-24-9 | SAE AS22759/44-24-9WHITEJudd Wire22
23MIL-W-22759/44-24-0 | SAE AS22759/44-24-0BLACKJudd Wire23
LINESHIELDED CABLE (Silver-Plated Copper) NOTE : COLORS OF WIRE INSULATION ARE NON-STANDARD. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET INSULATION COLORJudd WireLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
35M27500U 8SP1S23 8 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION).CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire35
36M27500U12SR1S23 12 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire36
37M27500U12SR2S23 12 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire37
38M27500U12SR3S23 12 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire38
39M27500U12SR4S23 12 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire39
40M27500U16SR1S23 16 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire40
41M27500U16SR2S23 16 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire41
42M27500U16SR3S23 16 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION).CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire42
43M27500U16SR4S23 16 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire43
44M27500U20SR1S23 20 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire44
45M27500U20SR2S23 20 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire45
46M27500U20SR3S23 20 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire46
47M27500U20SR4S23 20 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire47
48M27500U20SR6S23 20 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire48
49M27500U22SR1S23 22 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire49
50M27500U22SR2S23 22 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire50
51M27500U22SR3S23 22 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire51
52M27500U22SR4S23 22 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire52
53M27500U22SR6S23 22 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire53
54M27500U24SR1S23 24 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire54
55M27500U24SR2S23 24 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire55
56M27500U24SR3S23 24 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire56
57M27500U24SR4S23 24 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire57
58M27500U24SR6S23 24 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEJudd Wire58

Marmon Aerospace

LINEHOOK UP WIRE (Silver-Plated Copper)HOOKUP WIRE INSUALTION COLORMarmon Aerospace & DefenseLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
2MIL-W-22759/43- 6-3 | SAE AS22759/43- 6-3ORANGEMarmon Aerospace & Defense2
3MIL-W-22759/43- 8-3 | SAE AS22759/43- 8-3ORANGEMarmon Aerospace & Defense3
4MIL-W-22759/44-12-3 | SAE AS22759/44-12-3ORANGEMarmon Aerospace & Defense4
5MIL-W-22759/44-12-4 | SAE AS22759/44-12-4YELLOWMarmon Aerospace & Defense5
6MIL-W-22759/44-12-9 | SAE AS22759/44-12-9WHITEMarmon Aerospace & Defense6
7MIL-W-22759/44-12-0 | SAE AS22759/44-12-0BLACKMarmon Aerospace & Defense7
8MIL-W-22759/44-16-3 | SAE AS22759/44-16-3ORANGEMarmon Aerospace & Defense8
9MIL-W-22759/44-16-4 | SAE AS22759/44-16-4YELLOWMarmon Aerospace & Defense9
10MIL-W-22759/44-16-9 | SAE AS22759/44-16-9WHITEMarmon Aerospace & Defense10
11MIL-W-22759/44-16-0 | SAE AS22759/44-16-0BLACKMarmon Aerospace & Defense11
12MIL-W-22759/44-20-3 | SAE AS22759/44-20-3ORANGEMarmon Aerospace & Defense12
13MIL-W-22759/44-20-4 | SAE AS22759/44-20-4YELLOWMarmon Aerospace & Defense13
14MIL-W-22759/44-20-9 | SAE AS22759/44-20-9WHITEMarmon Aerospace & Defense14
15MIL-W-22759/44-20-0 | SAE AS22759/44-20-0BLACKMarmon Aerospace & Defense15
16MIL-W-22759/44-22-3 | SAE AS22759/44-22-3ORANGEMarmon Aerospace & Defense16
17MIL-W-22759/44-22-4 | SAE AS22759/44-22-4YELLOWMarmon Aerospace & Defense17
18MIL-W-22759/44-22-9 | SAE AS22759/44-22-9WHITEMarmon Aerospace & Defense18
19MIL-W-22759/44-22-0 | SAE AS22759/44-22-0BLACKMarmon Aerospace & Defense19
20MIL-W-22759/44-24-3 | SAE AS22759/44-24-3ORANGEMarmon Aerospace & Defense20
21MIL-W-22759/44-24-4 | SAE AS22759/44-24-4YELLOWMarmon Aerospace & Defense21
22MIL-W-22759/44-24-9 | SAE AS22759/44-24-9WHITEMarmon Aerospace & Defense22
23MIL-W-22759/44-24-0 | SAE AS22759/44-24-0BLACKMarmon Aerospace & Defense23
LINESHIELDED CABLE (Silver-Plated Copper) NOTE : COLORS OF WIRE INSULATION ARE NON-STANDARD. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORMarmon Aerospace & DefenseLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
35M27500U 8SP1S23 8 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION).CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense35
36M27500U12SR1S23 12 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense36
37M27500U12SR2S23 12 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense37
38M27500U12SR3S23 12 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense38
39M27500U12SR4S23 12 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense39
40M27500U16SR1S23 16 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense40
41M27500U16SR2S23 16 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense41
42M27500U16SR3S23 16 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION).CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense42
43M27500U16SR4S23 16 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense43
44M27500U20SR1S23 20 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense44
45M27500U20SR2S23 20 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense45
46M27500U20SR3S23 20 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense46
47M27500U20SR4S23 20 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense47
48M27500U20SR6S23 20 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense48
49M27500U22SR1S23 22 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense49
50M27500U22SR2S23 22 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense50
51M27500U22SR3S23 22 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense51
52M27500U22SR4S23 22 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense52
53M27500U22SR6S23 22 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense53
54M27500U24SR1S23 24 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense54
55M27500U24SR2S23 24 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense55
56M27500U24SR3S23 24 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense56
57M27500U24SR4S23 24 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense57
58M27500U24SR6S23 24 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGEMarmon Aerospace & Defense58

Quirk Wire

LINETHERMOCOUPLE CABLE. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORQuirk WireLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
59K-2019-SFJ-3 Type K 20 AWG 19 Strand FEP insulation (Standard Limits) SPC shield FEP Jacket with Marker Tape 200 deg C (orange outer jacket).CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire59
60K-2219-SFJ-3 Type K 22 AWG 19 Strand FEP insulation (Standard Limits) SPC shield FEP Jacket with Marker Tape 200 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire60
61K-2019-SPJ-3 Type K 20 AWG 19 Strand PFA insulation (Standard Limits) NPC shield PFA Jacket with Marker Tape 260 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire61
62K-2219-SPJ-3 Type K 22 AWG 19 Strand PFA insulation (Standard Limits) NPC shield PFA Jacket with Marker Tape 260 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire62
63K-2019-FJ-3 Type K 20 AWG 19 Strand FEP insulation (Standard Limits) unshielded FEP Jacket with Marker Tape 200 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire63
64K-2219-FJ-3 Type K 22 AWG 19 Strand FEP insulation (Standard Limits) unshielded FEP Jacket with Marker Tape 200 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire64
65K-2019-PJ-3 Type K 20 AWG 19 Strand PFA insulation (Standard Limits) unshielded PFA Jacket with Marker Tape 260 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire65
66K-2219-PJ-3 Type K 22 AWG 19 Strand PFA insulation (Standard Limits) unshielded PFA Jacket with Marker Tape 260 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire66
67J-2019-SFJ-3 Type J 20 AWG 19 Strand FEP insulation (Standard Limits) SPC shield FEP Jacket with Marker Tape 200 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire67
68J-227-SFJ-3 Type J 22 AWG 7 Strand FEP insulation (Standard Limits) SPC shield FEP Jacket with Marker Tape 200 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire68
69J-2019-SPJ-3 Type J 20 AWG 19 Strand PFA insulation (Standard Limits) NPC shield PFA Jacket with Marker Tape 260 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire69
70J-227-SPJ-3 Type J 22 AWG 7 Strand PFA insulation (Standard Limits) NPC shield PFA Jacket with Marker Tape 260 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire70
71J-2019-FJ-3 Type J 20 AWG 19 Strand FEP insulation (Standard Limits) unshielded FEP Jacket with Marker Tape 200 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire71
72J-227-FJ-3 Type J 22 AWG 7 Strand FEP insulation (Standard Limits) unshielded FEP Jacket with Marker Tape 200 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire72
73J-2019-PJ-3 Type J 20 AWG 19 Strand PFA insulation (Standard Limits) unshielded PFA Jacket with Marker Tape 260 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire73
74J-227-PJ-3 Type J 22 AWG 7 Strand PFA insulation (Standard Limits) unshielded PFA Jacket with Marker Tape 260 deg C (orange outer jacket). CABLE JACKET MUST BE UV LASER MARKABLEORANGEQuirk Wire74

TE Connectivity

LINEHOOK UP WIRE (Silver-Plated Copper)HOOKUP WIRE INSUALTION COLORTE ConnectivityLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
2MIL-W-22759/43- 6-3 | SAE AS22759/43- 6-3ORANGETE Connectivity2
3MIL-W-22759/43- 8-3 | SAE AS22759/43- 8-3ORANGETE Connectivity3
4MIL-W-22759/44-12-3 | SAE AS22759/44-12-3ORANGETE Connectivity4
5MIL-W-22759/44-12-4 | SAE AS22759/44-12-4YELLOWTE Connectivity5
6MIL-W-22759/44-12-9 | SAE AS22759/44-12-9WHITETE Connectivity6
7MIL-W-22759/44-12-0 | SAE AS22759/44-12-0BLACKTE Connectivity7
8MIL-W-22759/44-16-3 | SAE AS22759/44-16-3ORANGETE Connectivity8
9MIL-W-22759/44-16-4 | SAE AS22759/44-16-4YELLOWTE Connectivity9
10MIL-W-22759/44-16-9 | SAE AS22759/44-16-9WHITETE Connectivity10
11MIL-W-22759/44-16-0 | SAE AS22759/44-16-0BLACKTE Connectivity11
12MIL-W-22759/44-20-3 | SAE AS22759/44-20-3ORANGETE Connectivity12
13MIL-W-22759/44-20-4 | SAE AS22759/44-20-4YELLOWTE Connectivity13
14MIL-W-22759/44-20-9 | SAE AS22759/44-20-9WHITETE Connectivity14
15MIL-W-22759/44-20-0 | SAE AS22759/44-20-0BLACKTE Connectivity15
16MIL-W-22759/44-22-3 | SAE AS22759/44-22-3ORANGETE Connectivity16
17MIL-W-22759/44-22-4 | SAE AS22759/44-22-4YELLOWTE Connectivity17
18MIL-W-22759/44-22-9 | SAE AS22759/44-22-9WHITETE Connectivity18
19MIL-W-22759/44-22-0 | SAE AS22759/44-22-0BLACKTE Connectivity19
20MIL-W-22759/44-24-3 | SAE AS22759/44-24-3ORANGETE Connectivity20
21MIL-W-22759/44-24-4 | SAE AS22759/44-24-4YELLOWTE Connectivity21
22MIL-W-22759/44-24-9 | SAE AS22759/44-24-9WHITETE Connectivity22
23MIL-W-22759/44-24-0 | SAE AS22759/44-24-0BLACKTE Connectivity23

Tensolite

LINECOAXIAL CABLE. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORTensoliteLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
24M17/060-RG142 ORANGE XL-ETFE JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETensolite24
25M17/128-RG400 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETensolite25
26M17/ 94-RG179 ORANGE XL-ETFE JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETensolite26
27M17/113-RG316 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETensolite27
28M17/110-RG302 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETensolite28
LINETWINAXIAL/TRIAXIAL CABLECABLE JACKET COLORManufacturer 1LINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
32CABLE, RADIO FREQUENCY, FLEXIBLE, TWIN, M17/176-00002 ORANGE XL-ETFE JACKET 77 OHMORANGETensolite32

Times Microwave

LINECOAXIAL CABLE. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORManufacturer 1LINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
24M17/060-RG142 ORANGE XL-ETFE JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETimes Microwave24
25M17/128-RG400 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETimes Microwave25
26M17/ 94-RG179 ORANGE XL-ETFE JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETimes Microwave26
27M17/113-RG316 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETimes Microwave27
28M17/110-RG302 ORANGE FEP JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETimes Microwave28
29LMR-400UF RF (orange cable outer jacket preferred, black alternate) minimum segment length of 250 FEETORANGETimes Microwave29
30LMR-600UF RF (orange cable outer jacket preferred, black alternate) minimum segment length of 250 FEETORANGETimes Microwave30
LINETWINAXIAL/TRIAXIAL CABLE. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORManufacturer 3LINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
32CABLE, RADIO FREQUENCY, FLEXIBLE, TWIN, M17/176-00002 ORANGE XL-ETFE JACKET 77 OHM. CABLE JACKET MUST BE UV LASER MARKABLEORANGETimes Microwave32
34CABLE, RADIO FREQUENCY, FLEXIBLE, TRIAXIAL, 95 OHMS, M17/178-00001 ORANGE BRAIDED JACKET. CABLE JACKET MUST BE UV LASER MARKABLEORANGETimes Microwave34

Tyco Electronics

LINESHIELDED CABLE (Silver-Plated Copper) NOTE : COLORS OF WIRE INSULATION ARE NON-STANDARD. OUTER JACKET MUST BE UV LASER MARKABLECABLE JACKET COLORTyco ELectronicsLINEMINIMUM BUY QTY (OR NO-BID)1,000 ft ($/ft)2,500 ft ($/ft)5,000 ft ($/ft)10000 ($/ft)15,000 ft ($/ft)20,000 ft ($/ft)LEAD TIME WEEKS ARO
35M27500U 8SP1S23 8 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION).CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics35
36M27500U12SR1S23 12 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics36
37M27500U12SR2S23 12 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics37
38M27500U12SR3S23 12 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics38
39M27500U12SR4S23 12 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics39
40M27500U16SR1S23 16 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics40
41M27500U16SR2S23 16 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics41
42M27500U16SR3S23 16 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION).CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics42
43M27500U16SR4S23 16 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics43
44M27500U20SR1S23 20 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics44
45M27500U20SR2S23 20 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics45
46M27500U20SR3S23 20 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics46
47M27500U20SR4S23 20 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics47
48M27500U20SR6S23 20 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics48
49M27500U22SR1S23 22 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics49
50M27500U22SR2S23 22 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics50
51M27500U22SR3S23 22 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics51
52M27500U22SR4S23 22 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics52
53M27500U22SR6S23 22 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics53
54M27500U24SR1S23 24 AWG 1 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics54
55M27500U24SR2S23 24 AWG 2 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics55
56M27500U24SR3S23 24 AWG 3 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics56
57M27500U24SR4S23 24 AWG 4 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics57
58M27500U24SR6S23 24 AWG 6 COND SHIELDED, ORANGE XL-ETFE JACKET, INNER COLOR CODE 9+0+2+5+3+6 (NOTE: NON-STANDARD WIRE INSULATION COLORS IN PART DESCRIPTION). CABLE JACKET MUST BE UV LASER MARKABLEORANGETyco Electronics58