This document is a Questions and Answers (Q&A) file for a mobile ballistic shield or protective structure with specific technical requirements. The detailed specifications include a 36" x 46" x 77" dimension panel, a non-retractable but removable awning, and a steel-framed structure with sides. Key requirements include a ballistic-rated design that can protect personnel from natural elements, a partially concealed transparent panel allowing the sentry to look outward, and a wheel assembly that can extend from the front of the structure. Additional specifications mandate a NIJ III square transparent anti-ballistic panel and an electrical infrastructure for powering a space heater and infrared heater, with electrical plug-ins confirmed to be available on-site.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Q and A - Mobile Ballistic Shields 26 Aug 25_FINAL - Rev 2.pdf | ||
| Combo Synopsis Solicitation - Mobile Ballistic Shields - Rev 2_FINAL.pdf | ||
| Q and A - Mobile Ballistic Shields 26 Aug 25_FINAL- Rev 1.pdf | ||
| Combo Synopsis Solicitation - Mobile Ballistic Shields.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Q&A
1. Please include dimension labeling on measurements for panel and awning. (Depth, Length, Height)
36" x 46" x 77"
2. Does the awning need to be retractable, and is there a preferred material?
Awning does not need to be retractable. However, it should have the capability to be removed. It also needs to be ballistic rated as the mobile shield itself and the awning designed to protect personnel utilizing the mobile shield from the sun, rain and other natural elements.
3. Can aluminum be used for the base structure, or is steel preferred?
Steel is preferred.
4. Do you want the ballistic panel to be fully transparent? Or would you like to incorporate a 1-way film or non-transparent section to conceal personnel and weapons?
It should conceal personnel and weapons with the sentry having the capability to look through same outward.
5. Do you want sides on the structure or just a front facing window panel?
It needs to have sides.
6. Does the frame need to be flush to the front of the panel, or can the wheel assembly extend from the front of the structure?
Wheel assembly can extend from the front of the structure
7. We note that a space heater is required. Will electric or gas plug-ins be available on-site or will we need to provide the ability to add a generator or gas storage support.
Electrical plug-ins are available on site.
8. Does the awning needing to be anti-ballistic?
It needs to be ballistic rated as the mobile shield itself
9. Does a transparent anti-ballistic panel need to be integrated into the unit? Yes If so, is NIJ III and a square design an appropriate protection level and shape for this transparent panel?
Yes
10. For the infrared heater, will the unit have access to electricity or will a gas powered unit be needed?
Electrical plug-ins are available on site.